You are on page 1of 337

NEW DEVELOPMENT OF OECUSSE AIRPORT

DESIGN NOTES
Revision 02, Date : 16/09/2016

1. INTRODUCTION
An airport is an aerodrome with facilities for flights to take off and land. Airports often
have facilities to store and maintain aircraft, and a control tower. An airport consists of
a landing area, which comprises an aerially accessible open space including at least one
operationally active surface such as a runway for a plane to take off or a helipad, and
often includes adjacent utility buildings such as control towers, hangars and terminals.
Larger airports may have fixed-base operator services, airport aprons, air traffic control
centers, passenger facilities such as restaurants and lounges, and emergency services.
An airport with a helipad for rotorcraft but no runway is called a heliport. An airport for
use by seaplanes and amphibious aircraft is called a seaplane base. Such a base typically
includes a stretch of open water for takeoffs and landings, and seaplane docks for tying-
up. An international airport has additional facilities for customs and immigration. Most of
the world's airports are owned by local, regional, or national government bodies.

1.1. Vision
To become a growing area, what Oecusse needs is a reliable mode of
transportation than will open opportunities for tourist or maybe investor to help
Oecusse develop itself. Oecusse in Timor Leste Government Plan will be an
example for any other provinces in Timor Leste, and that is why this airport will
become very important for Oecusse.

1.2. Purpose and Need


The development of the Oecusse Special Administrative Region (RAEOA),
integrated in the Special Zones of Social Market (ZEESM) aims at providing a new
centrality and associated development for a twofold insular region of Timor-
Leste. Timor is an island and Oecusse is an enclave located in the West Timor
Indonesia NTT Province making the connection between Oecusse and the
mainland of Timor-Leste difficult, costly and time consuming.
In order to provide Oecusse with easier access, required for its development, and
to provide for the needs of its population, it was determined that an International
Airport was to be built, capable of providing direct, easy, cost-efficient, safe and
regular access to and from Oecusse, not only from a range of international
airport of origin/destination.

1.3. Goal and Objectives


In order to make Oecusse developed, the airport must be an international
airport, to make people come to Oecusse. To buildan international and reliable
airport, we need to make sure that all facilities in Oecusse airport is certified
worthy. Because if Oecusse want this airport to be an international then it has to
be certify by Timor Leste Government and admitted by International Aviation
Association. So the international airlines want to open their routes to Oecusse.

1
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

2. FACILITIES REQUIREMENTS
2.1. Codes and Regulations
In reviewing and planning New Development of Oecusse Airport Project
Consultant using following standards:
a. International Standard and Recommended Practices, Aerodromes, Annex 14,
Volume I Aerodrome Design and Operations, Sixth Edition, July 2013,
International Civil Aviation Organization (ICAO);
b. International Air Transport Association (IATA) Airport Development Reference
Manual (ADRM) 9th Edition.
c. Aerodrome Design Manual, Doc. 9157-AN/901, Part 1 Runways, Third Edition
— 2006, ICAO;
d. Aerodrome Design Manual, Doc. 9157-AN/901, Part 2 Taxiways, Apron and
Holding Bays, Fourth Edition, 2005, ICAO;
e. Aerodrome Design Manual, Doc. 9157-AN/901, Part 3 Pavements, Second
Edition; 1983, ICAO;
f. Aerodrome Design Manual, Doc. 9157-AN/901, Part 4 Visual Aid, Fourth
Edition, 2004, ICAO;
g. Advisory Circular, Design and Installation for Airport Visual Aids, AC
150/5340-30G, 2012, Federal Aviation Administration.
h. Koerner, R. M., Designing with Geosynthetics, Fifth Edition, United States of
America, 2005.
i. Liong, G. T., Geosynthetics Design Concept for Road Construction. Seminar
on ―Road Construction in Indonesia with Special Reference to the Role of
Geosynthetics‖, 2006.
j. Hussin, N.A.B., Correlation between CBR Value and Undrained Shear
Strength from Vane Shear Test, Faculty of Civil Engineering of University
Technology Malaysia, 2008.

2.2. Planning Assumptions


a. Scope
To develop an airport within the assigned land space area, meeting all
feasible ICAO criteria for international passenger and cargo operation.
The design specification and construction calculations shall be documented
for review and approval by the supervision consultant under the guidance of
the President of RAEOA.
b. Critical Airplane
For design, flexible pavement strength and overall dimensions and
requirements it was determined that the critical airplane to be considered will
be the Boeing B737-800. Nevertheless, the pavements strength for the
runway, taxiway and parking and their dimensions must be designed and
constructed to withstand the operation of wide bodyairplanes although to a
much lesser frequency of less than 300 movement per year.

2
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

c. Since there is no historical data to base any credible forecasts of yearly and
peak hour traffic of passengers and number of air movements, some
assumptions had to be made in order to anticipate future demands.
d. For all purpose the following numbers are to be considered in the design
review of the movement area :
i. The airport must be capable of 24 hour operation;
ii. There must be at least one instrument non-precision approach runway;
iii. The Apron, Apron feeding taxiway must be able to accommodate the
parking of four aircraft B737-800 or equivalent or, two aircraft 737-800
or equivalent and one A330-300 or equivalent at same time

3
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

3. MASTER PLAN OVERVIEW


3.1. Introduction
The concept of Oecusse Airport Masterplan, East Timor was made based on the
assumption that there has been coupled with the latest data and the need for
infrastructure and facilities in the field. The main thing to do is to verify the
measurement area of land or land that is planned. Results superimpose its use as
a material planning and position of buildings supporting facilities.

Magnetic bearing;
A runway designation marking shall consist of a two-digit number and on parallel
runways shall be supplemented with a letter. On a single runway, dual parallel
runways and triple parallel runways the two-digit number shall be the whole
number nearest the one-tenth of the magnetic North when viewed from the
direction of approach. On four or more parallel runways, one set of adjacent
runways shall be numbered to the nearest one-tenth magnetic azimuth and the
other set of adjacent runways numbered to the next nearest one-tenth of the
magnetic azimuth. When the above rule would give a single digit number, it shall
be preceded by a zero.
OECUSSE AIRPORT BEARING CALCULATIONS
DECIMAL DEGREES
LATITUDE LONGITUDE LATITUDE LONGITUDE
0
COORD THD RW -9.194770 124.348085 9 11‘39.0366‖S 124020‘53.1054‖S
27
COORD THD RW -9.195266 124.328105 9011‘42.9576‖S 124019‘41.1774‖S
09
COORD ARP -9.794401 124.338989 9011‘39.8430‖S 124020‘20.3598‖S

PANTE MACASSAR MAGNETIC VARIATION : 1.600E


DECIMAL DEGREES
TRUE MAGNETIC TRUE MAGNETIC
0
BEARING RW 27 266.839700 265.273100 266 50‘23‖ 265016‘23‖
BEARING RW 09 -86.839720 -85.273060 86050‘23‖ 85016‘23‖

So Oecusse Airport has magnetic bearing for 086050‘29‖and 266050‘29, the


runway designation number will be 09 and 27.Location (coordinates)

Aerodrome Reference Point for Oecusse Airport is located at the highest point of
design elevation at STA 1+350. The coordinate is:
Latitude (degree) : -9.194401

4
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Longitude (degree) : 124.338989


3.2. Master Plan Development Process

Oecusse Masterplan Phase 1

Phase 1 Masterplan (2016):

a) The Airport Area already comply with the latest topography;

b) 2.200 m Runway

c) Terminal Building with Gross Floor Area of 8.500 m2.

d) Terminal Cargo Complex with Gross Floor Area 600 m2.

e) Ground Support Equipment Shelter with Gross Floor Area 600 m2.

f) Air Traffic Control Tower and its equipment.

g) Meteorological Office with its equipment.

h) DVOR/DME Facility.

i) Quarantine Building Facility 250 m2.

j) Apron area 138 m x 250 m.

k) 2 Taxiways, Alpha and Bravo.

l) Cars, Buses, Taxis and Motorcycle parking lot.

m) The Ground Water Tank and Sewage Treatment Plan will be undergrounded;

n) The ATC position already comply the regulations to accommodate the


minimum allowable distance from the aircraft movement area;

o) Amount of vehicle that already optimize to the amount of passenger at peak


hour;

p) Fuel Depot facility required 600 sqm area;

q) Area requirements for RFFS Building and also its access already comply with
the International Standard;

r) Inspection Road/Perimeter Road aligned with the Airport Fence;

5
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

3.3. Ultimate Master Plan

Oecusse Airport, Timor Leste Final Phase Masterplan

Final Phase Masterplan:

a) 2.500 m Runway

b) Terminal Building expansion.

c) Cargo Complex expansion.

d) Fuel Depot Facility expansion.

e) Cars, buses, taxis, and motorcycles parking lot expansion.

f) 1 Parallel Taxiway

g) Cargo Apron

h) Reclamation Area

i) Additional Bus Depot

j) Additional Taxi Depot

k) Public Road Extension

6
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

4. AIRFIELD
4.1. Introduction
In Oecusse, we use Non-precision Instrument Approach.
Non-precision instrument runways are often used at small- to medium-size
airports. These runways, depending on the surface, may be marked with
threshold markings, designators, centerlines, and sometimes a 1,000 ft (305m)
mark (known as an aiming point), sometimes installed at 457m. They provide
horizontal position guidance to planes on instrument approach via Non-directional
beacon, VHF omni directional range, Global Positioning System, etc.

4.2. Base Data and Assumptions

Phase Aircraft Type

 De Havilland Twin Otter


 B737-800 (Critical Aircraft)
Design Phase
 A330-300
 ATR- 72

Airport Planning Data


No Items Details
Oecusse – Kupang – Oecusse

Oecusse – Denpasar – Oecusse


Oecusse – Makassar - Singapore -
Makassar – Oecusse
Oecusse – Darwin – Oecusse
Oecusse – Dili – Oecusse

Oecusse – Suai – Oecusse


Flight Routes
1
Possibilities

Source: Zeesm-TL Proposal, July 2014.


http://www.laohamutuk.org/econ/Oecussi/ABZE
ESMUNTL4Jul2014.pdf
Presidente Nicolau Lobato International
2 Alternate Airport Airport, Dili
(IATA : DIL, ICAO : WPDL)
Distance to Alternate
3 150 Kilometers
Airport
4 Temperature 26.5o C (source : en.climate-data.org)
5 Elevation + 3.7 m AMSL
Average Slope
6 0.04875%
Longitudinal R/W
7 Wind Component 0 (Assumption)

7
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

ATR-72/200 Aircraft Specifications


MODEL
CHARACTERISTIC UNIT ATR
72/200
Maximum Take Of Weight Kilograms 21.500
Maximum Landing Weight Kilograms 21.350
Maximum Zero Fuel Weight Kilograms 19.700
Operating Empty Weight Kilograms 12.500
Length Meters 27,17
Wingspan Meters 27,05
Height Meters 7,65
Wheelbase Meters 9,6
Maximum Seat Capacity PAX 2 + 74
Two Pratt & Whitney PW
Engines
124B Turboprops
Maximum Payload Kilograms 7.200
Maximum Fuel Weight Kilograms 5.000
Maximum Operations Altitude Meters 25.000
Take-off Length at MTOW,ISA, S/L (Flaps 150) Meters 1.408
Take field Length at MLW,ISA, S/L Meters 1.210
Range, Max Optimal Payload Kilometers 1.195

Boeing B737-800 Aircraft Specifications

Airbus A330 Aircraft Specifications (Biggest Aircraft)

8
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

4.3. Runway
In calculating the length of the planning runway (runway) used standard called
Aircraft Reference Field Length (ARFL), ARFL is the minimum required runway for
take-off. At the time of maximum takeoff weight, sea level, temperature and
slope of the elongated runway, each type of aircraft has ARFL different depending
on the specifications of the aircraft maker. Oecusse Airport will have Boeing 737-
800 as critical aircraft. Nevertheless the pavements strength for the Runway,
taxiways and apron and their dimension designed ready for wide body aircraft
such as Airbus A330-300.Length of the Runway determinate by these factors:
 Characteristic of the critical aircraft than will land and take off;
 Weather, mostly wind and temperature;
 Runway characteristic like existing surface and slope;
 Location of the airport and surface elevation that will affect to air pressure
and topography parameters.

Calculations for the Runway are related to the critical aircraft that will be using
the Runway (Boeing 737-800), based on these factors:
 Operating Empty Weight (OEW);
 Pay load for longest route;
 Landing Weight - can‘t exceed Maximum Structural Landing Weight allowed
at the destination airport;
 Fuel needs during climbing, cruise and descent, IFR Reserves and Alternate
Airport Diversion.
 Aircraft takeoff weight was calculated by summing the weight of fuel required
where the weight does not exceed structural take-off weight permitted for
the aircraft.

Runway Length Calculation


Based on ISQ and ZEESM-TL Documents about New Development for Oecusse
Airport, we can summarize these data:
 Airport Origin = Oecusse, Timor Leste
 Average Temperature = 26.50 C (en.climate-data.org)
 Average Slope = 0.04875%
 Airport Elevation = 3,7 m AMSL
 Alternate Airport = Dili Airport (DIL)
 Alternate Airport Distance = 150 Km
 Critical Aircraft = Boeing 737-800

9
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

General calculations for Take-off Weight and Range

As we can see, correcting the RWY length for the average temperature (ISA +
15ºC), the B737-800 can take-off with a MTOW of 75.500Kg. However this
is only useful for general planning. Airline specific operating procedures will
apply.

As we can see in this table, for a MTOW of 75,500Kg, we obtain an OEW plus
payload of 59,200Kg and a fuel load of 16,300 Kg. Under these conditions, for
Oecusse, in general terms (depending on operators operating procedures), the
B737-800 has a maximum theoretical range of over 2,000NM (3.600
KM).

10
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Under same conditions (ISA + 15ºC) the A320 with this engine can take-off from
Oecusse with a 2200m RWY at a MTOW of 77,500Kg, which is almost its
Maximum Design MTOW of 78,000Kg.

And as in ICAO Annex 14, Attachment A-3, Fig A-1 these are the relevant design
for declared distance for the runway:

11
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

12
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Oecusse Runway Declared Distance


NO DESCRIPTION RWY 07 RWY 29
1 Runway Length 2.200 m 2.200 m
2 Runway Strip 2.440 m x 300 m 2.440 m x 300 m
3 Stopway 60 m 60 m
4 RESA 90 m 90 m
5 Cleanway 210 m 210 m
6 Take Off Run Available (TORA) 2.200 m 2.200 m
7 Take Off Distance Available (TODA) 2.410 m 2.410 m
8 Accelerate Stop Distance Available (ASDA) 2.260 m 2.260 m
9 Landing Distance Available (LDA) 2.200 m 2.200 m

In Project Description Report document that made from ISQ assumption, it


stated that the airport will have Boeing B737-800 for critical aircraft.
Nevertheless, the airport must be designed and constructed to withstand the
operation of Wide body Aircraft although to a much lesser frequency of less than
300 movements per year. The Runway will be 2200 m x 45 m; the longitudinal
and transverse slopes of the Runway shall be according to those prescribed on
ICAO Annex 14.

4.4. Runway Shoulder


Below is the requirement about Runway, based on ICAO Annex 14:

Item Code Number


1 2 3 4
Width of Runway
Code Letter A 18 m 23 m 30 m -
Code Letter B 18 m 23 m 30 m -
Code Letter C 23 m 30 m 30 m 45 m
Code Letter D - - 45 m 45 m
Code Letter E - - - 45 m
Width of Runway plus Where the code letter is D or E, the over-all
shoulders width of the Runway and its shoulders shall
not less than 60 m
Width of Runway strip
Precision and non-precision 300 m
150 m 150 m 300 m
Runway
Non-instrument Runway 60 m 80 m 150 m 150 m
Strip
Max longitudinal Slope 2% 2% 1.75% 1.5%
Max transverse Slope 3% 3% 2.5% 2.5%
Source: ICAO Annex 14, Volume I, Aerodrome

Runway Shoulder should able to withstand the aircraft load that slipped out
outside the runway. And also must be able to withstand the Emergency Vehicles
for Rescue. Based on ICAO Annex 14, Total Shoulder Width (Including Runway
Width) for Aircraft Category 4E is 60 m. So the calculation will be as follow:

13
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Runway Shoulder = (Total Shoulder Width – Runway Width for 4E)/2


= (60 m – 45 m) / 2
= 7,5 m
The Biggest Aircraft at Oecusse Airport will be The Airbus A330-300, and if we
refer to ICAO Annex 14 so the Runway Shoulder should be 7.5 m.

4.5. Stopway
Stopway Dimension will be as minimum as allowed by ICAO Annex 14, it will be
60 m x 60 m.

4.6. Runway Strip


Runway Strip is defined as the area surrounding the runway that is prepared or
suitable for reducing damage to aircraft in the event of unintentional excursion
from the runway surface. According to the International Civil Aviation
Organization (ICAO), a runway is a "defined rectangular area on a land
aerodromeprepared for the landing and takeoff of aircraft". Runways may be a
man-made surface (often asphalt, concrete, or a mixture of both) or a natural
surface (grass, dirt, gravel, ice, or salt).
Runway Strip for Non Precision and Precision Approach Runways

If the runway is an instrument runway like in Oecusse, Runway Strip is a graded


area around the runway and Stopway, and also known as ″fly-over area″ outside
the graded area. Technically, flyover area is an ungraded area around the graded
area.

Code Number
Width of Runway strip 1 2 3 4
Precision and non-precision runway 150 m 150 m 300 m. 300 m
Non-instrument runway 60 m 80 m 150 m 150 m

Source: Airport Planning Manual (Doc 9184-AN/902) Part 1, Master Planning, ICAO, 1987

Based on ICAO Doc 9184, for Instrument Non-Precision Runway, Oecusse Airport
will have a 2.440 m x 300 m Runway Strip.

14
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

4.7. Runway End Safety Area (RESA)


A runway safety area (RSA) or runway end safety area (RESA) is defined as "the
surface surrounding the runway prepared or suitable for reducing the risk of
damage to airplanes in the event of anundershoot, overshoot, or excursion from
the runway.
Past standards called for the RSA to extend only 60m (200 feet) from the ends of
the runway. Currently the international standard ICAO requires a 90m (300 feet)
RESA starting from the end of the runway strip (which itself is 60m from the end
of the runway), and recommends but not requires a 240m RESA beyond that. In
the U.S., the recommended RSA may extend to 500 feet in width, and 1,000 feet
beyond each runway end (according to U.S. Federal Aviation Administration
recommendations; 1000 feet is equivalent to the international ICAO-RESA of
240m plus 60m strip). The standard dimensions have increased over time to
accommodate larger and faster aircraft, and to improve safety.
The minimum dimension for RESA is twice from the Runway Width with minimum
90 m length.So Oecusse Airport will have 2 RESA, one on each of the runway,
with the dimension of 90 m x 90 m each

4.8. Runway Profile


On planning the Oecusse runway, we connect the runway to a double taxiway
system which in turn and connect to the apron, and their dimensions and location
are designed to comply with safety standards and provide good traffic flow. The
designed RWY length results from a balance between fully satisfying critical
aircraft requirements and cost concerns.

Runway Elevation
According to Sea Level Survey that already done, from WIKA and ISQ for 28 days
(November 10th 2015 to December 10th 2015) at Coast Line at STA 2+600. The
Highest Sea Level is 4,32 m and The Lowest Sea Level is 1,92 m.
So we can get The Mean Sea Level with formula below:

MSL = (HWL + LWL) / 2


= (4,32 + 1,92) / 2
= 3,12 m
Where:
HWL = Highest Water Level
LWL = Lowest Water Level

15
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

And as for projections:

Source: http://www.pacificclimatechangescience.org/wp-content/uploads/2013/09/East-Timor.pdf

Source: http://www.pacificclimatechangescience.org/wp-content/uploads/2013/09/East-Timor.pdf

16
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

From data above we can set the runway elevation with this formula:
RE = HWL + HWLP + DC + DD + RSD
= 4,32 + 0,21 + 0,5 + 0,8 + (1,5% * 75 )
= 7,0 m

Where:
RE = Runway Centerline Elevation (m)
HWL = Highest Water Level (m)
HWLP = Highest Water Level Projection on 2055 (m)
DC = Drainage Cleanance from High Water Level (m)
DD = Drainage Depth (m)
RS = Runway Strip Slope (%)
D = Distance between Drainage and Runway Centerline (m)

Longitudinal Slope
The highest surface of the runway is at STA 1+340 m from, it is about 7,0 m.
Threshold 08 (TH.08) will be at STA 0+150 and Threshold 26 will be at STA
2+350.

a. From STA 0+150 until STA 0+520 will have 0.075% slope.
b. From STA 0+520 until STA 1+340 will have 0.02% slope.
c. From STA 1+340 until STA 2+000 will have -0.02% slope.
d. From STA 2+000 until STA 2+350 will have -0.08% slope.

So the elevations for both threshold (TH.08 and TH.26) will be at:
a. TH.08 will have elevation at :

17
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

7,0 m – ( ( 1340 – 520 ) * 0.02) – ( ( 520 – 150) * 0.075 ) )


7,0 m – 0,164 m – 0,2775 m = 6,55 m
b. TH.26 will have elevation at :
7,0 m – ( ( 2000 – 1340 ) * 0.02) – ( ( 2350 – 2000) * 0.08 ) )
7,0 m – 0,132 m – 0,28 m = 6,58 m

Transverse Slope
Transverse Slope at Oecusse Airport is at minimum range the ICAO Annex 14
stated, its 1.0%. This is intended to reduce the amount of the land fill and due to
the lack of rainfall in the area around Oecusse, as it can be seen below:

Source: Timor Leste Rainfall Data

4.9. Turn Pad


Where the end of a runway is not served by a taxiway or a taxiway turnaround
and where the code letter is D, E or F, a runway turn pad shall be provided to
facilitate a 180-degree turn of aircrafts. Such areas may also be useful if
provided along a runway to reduce taxiing time and distance for aircrafts which
may not require the full length of the runway. The runway turn pad may be
located on either the left or right side of the runway and adjoining the runway
pavement at both ends of the runway and at some intermediate locations where
deemed necessary. The initiation of the turn would be facilitated by locating the
turn pad on the left side of the runway, since the left seat is the normal position
of the pilot-in-command. The intersection angle of the runway turn pad with the
runway should not exceed 30 degrees. The nose wheel steering angle to be used
in the design of the runway turn pad should not exceed 45 degrees. The design

18
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

of a runway turn pad shall be such that, when the cockpit of the aircraft for which
the turn pad is intended remains over the turn pad marking, the Cleanance
distance between any wheel of the aircraft landing gear and the edge of the turn
pad shall be not less than that given by the following tabulation:

Where severe weather conditions and resultant lowering of surface friction


characteristics prevail, a larger wheel-to-edge Cleanance of 6 m should be
provided where the code letter is E or F.The longitudinal and transverse slopes on
a runway turn pad should be sufficient to prevent the accumulation of water on
the surface and facilitate rapid drainage of surface water. The slopes should be
the same as those on the adjacent runway pavement surface.

4.10. Taxiways
Based on ISQ Assumption, Oecusse Airport will have 3.600 movements per year,
nevertheless, in the future; there may be 300 movements for Wide body Aircraft
such as Airbus A330-300. In the previous design, Oecusse Airport just had 1
Taxiway, and the Wide body Aircraft would have to be pushed back to the
Runway for engines start up because of the A330-300 Jet Blast while taxiing to

19
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

the RWY, did not have enough distance separation to an object in Apron (Safety
requirement).To simplify the taxiing procedure for A330-300 in a future airport
development, we have to avoid push back Wide body Aircraft to the Runway.
Wide body Aircraft will start engines from the Apron Taxilane and taxiing to the
RWY via one of the horn shaped TWY, never exposing the jet blast to objects on
the Apron below safe distances. SoOecusse Airport will need 2 Taxiways to
connect between apron and runway, to ensure a minimum distance Cleanance for
jet blast for Airbus A330-300 as below:

Airbus A330-300 Breakaway Power GE CF6-80E1 engine

General
Taxiways should be provided to allow for the safe and expeditious surface
movement of aircraft. Sufficient entrance and exit taxiways for a runway should
be provided to expedite the movement of aircrafts to and from the runway and
provision of rapid exit taxiways, where practical, considered when traffic volumes
are high.
The design of a taxiway should be such that, when the cockpit of the aircraft for
which the taxiway is intended remains over the taxiway center line markings, the
Cleanance distance between the outer main wheel of the aircraft and the edge of
the taxiway should be not less than that given by the following tabulation:

20
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

As of 20 November 2008, the design of a taxiway shall be such that, when the
cockpit of the aircraft for which the taxiway is intended remains over the taxiway
centre line markings, the Cleanance distance between the outer main wheel of
the aircraft and the edge of the taxiway shall be not less than that given by the
above tabulation

Taxiway Width
A straight portion of a taxiway should have a width of not less than that given by
the following tabulation:

Changes in direction of taxiways should be as few and small as possible. The radii
of the curves should be compatible with the maneuvering capability and normal
taxiing speeds of the aircrafts for which the taxiway is intended. The design of
the curve should be such that, when the cockpit of the aircraft remains over the
taxiway centre line markings.

21
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

The Taxiway Width determined by outer main gear wheel span for biggest
aircraft distance plus Cleanance.
Taxiway Width can be declared as below:
Wt = Tm +2C
Where:
WT =Taxiway Width
TM =Biggest Aircraft outer main gear wheel span
C = Cleanance (distance between outer wheel to taxiway
edge)

In Oecusse Airport Project, the biggest planned aircraft in a future development


is the Airbus A-330-300.A330-300 have 12,61 m Outer Main Gear Wheel Span,
as it can seen below.

22
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

So in Oecusse Airport Project, the minimum taxiway width should be:

WT = 12,61 + (2*4,5) = 21,61 m

And the minimum taxiway width referring to Airbus for Airport Planning Manual
for A330-300 is 23 m. As it can be seen below:

23
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

4.11. Apron Taxiways and Aircraft Stands Taxilane


Apron Taxi Lane distance from RWY centre line is determined by runway strip and
also by the height of aircraft tail that nose in to the apron. So based on ICAO
Annex 14 Part 1, the distance between Runway Centerline to the Apron Taxilane
in Oecusse Airport determined by this table below.

24
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Source: ICAO Aerodromes ANNEX 14

4.12. Taxiway Slope


Longitudinal Slope
Longitudinal Slope Profile determined by :
 Access to apron
 Provide easiness to apron
 Considering the maximum 1,5% slope allowed.
Transversal Slope
 Transversal Slopes for Taxiway follow the ICAO Annex 14 Recommendation
for 1.5 % for each side.

4.13. Exit Taxiway


For normal exit taxiway (Not Rapid Exit Taxiway), turning degree between
runway centerline and taxiway centerline is 90° with normal exit taxiway width
23 m.

4.14. Exit Taxiway Shoulder


Taxiway shoulder must be able to withstand the aircraft load that slipped out
outside the runway. And also must be able to withstand the Emergency Vehicles
for Rescue.
Based on ICAO Annex 14, the minimum total taxiway width including shoulder is
44 m, so the Taxiway Shoulder Width will be:
Taxiway Shoulder = (Total Taxiway Width – Taxiway Width) / 2
= (44 m – 23 m) / 2
= 10,5 m

4.15. Exit Taxiway Location


The location of normal exit taxiway is determined by these factors :

25
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 Critical Aircraft
 Touchdown Speed
 Touchdown Location
 Initial speed when entering HSET
 Aircraft Deceleration
 Terminal Location
 Apron Location
 Runway Location
 Other Taxiway Location
 Land Availability

Because of the annual aircraft movement at Oecusse Airport Project is only 3.600
movement (least movement), and because of land availability, and also the
location of apron and passenger terminal location is in the center of the runway,
so we set the exit taxiway location is in the center of the runway.
The connecting TWYs are two and they are not located to be exit TWY. If an
aircraft cannot exit in one of them, then can taxi down the RWY and turn around
at the existing Turn Pad. And it minimum dimension for exit taxiway for biggest
aircraft (Airbus A330-300, Category E Aircraft) can be seen on next page:

Source: Airbus for Airport Planning

26
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

4.16. Apron
Several factors that have to be considered for Apron Planning are:
 Size and aircraft maneuver characteristic that will used the apron;
 The number of aircraft;
 Cleanance Distance between aircraft;
 Airport Function (cargo or terminal or parking stand);
 Aircraft landing activities;
 Taxiway dimension;
 Apron slope. Based on ICAO Annex 1, apron slope must not exceed 1% to
avoid undesirable aircraft movement on the apron;
 Aircraft parking position, is it nose out or nose in or else;
 Terminal Position;
 Load Factor.

4.17. Apron Dimension


Apron Configuration at peak hour is for 7 aircrafts with these mixing
configuration:
a. Boeing B737-8004 : 4
b. ATR 72-600 :2
c. Airbus A330-300 : 1 (take 2 B737-800 Parking Stand)

27
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Aircrafts Wingspan Number Length (m)


(m) of Aircraft

B737-800 35,79 4 39,47


Cleanance 4,5 4 4,5
A330-300 60,3 1 63,67
Cleanance 7,5 1 7,5
ATR 72-600 27,050 2 27,166
Cleanance 3 2 3

180

So from data above we can calculate the minimum dimension for apron
requirement as follows:
Apron Minimum Width = Aircraft Nose Cleanance + Biggest Aircraft Length +
Aircraft Width Taxi Cleanance + ½ Aircraft Width + ½
Apron Taxi lane Width
= 15 + 64 + 10 + 30,15 + 11,5
= 130,65 m ≈ 135 m

Apron Minimum Length = 4 B737-800 Width + 5 B737-800 Width Cleanance + 2


ATR72-600 Width + 2 ATR72-600 Width Cleanance
= ( 4 * 35,79 ) + ( 5 * 4,5 ) + ( 2 * 27,050 ) + ( 2 * 3
)
= 143,16 + 22,5 + 54,1 + 6
= 224,76 m ≈ 225 m

Oecusse Apron is planned for the following dimensions designed for future wide
body Aircraft operation: 138 m x 250 m

4.18. Apron Profile


Longitudinal Slope, Apron Longitudinal Profile base on these factors:
- Access Easiness to the runway.
- Access Easiness to the taxiway.
- Considering the maximum slope allowed on apron as ICAO Annex 14 stated.
Apron Longitudinal in Oecusse Airport is 0,50% and already comply to ICAO
Annex 14, sixth edition July 2013.

4.19. Marking
Marking in the area of aircraft movements at airports is a sign written or drawn
on the aircraft movement area with a view to providing a user with information
about the aerodrome for aviation safety. Signs are symbols or signs placed or
installed in the aircraft movement area intended to provide aerodrome
information.

28
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

The aerodrome is used for landing and takeoff of aircraft, embarking and
disembarking of passengers and / loading or unloading cargo and / or mail, and
equipped with facilities for flight safety and as a transfer between modes of
transportations.
Aerodrome Air Traffic Control Tower (ATCT) is a unit that is located within
airports to provide air traffic control for the airspace serving the airport.
Aviation safety is a state regulated function to ensure the safe, orderly and
expeditious movement of air traffic in accordance with operating procedures and
technical airworthiness requirements for facilities and infrastructure along with
supported flights.

Technical Requirements
The Markings in the aircraft movement areas are markings written or drawn on
the surface of the runway, taxiways, taxi lanes and Apron that conform with the
standards prescribed in ICAO Annex 14.
A. Runway markings consist of:
1. Runway Side Stripe Marking.
2. Runway Designation Marking
3. Runway Threshold Marking
4. Runway Center Line Marking
5. Aiming Point Marking
6. Touchdown Zone Marking
7. Runway Turn Pad Marking

B. Taxiway Markings consist of:


1. Taxiway Centre Line Marking
2. Runway Holding Position Marking
3. Taxiway Edge Marking
4. Taxiway Shoulder Marking
5. Exit Guide Line Marking
6. Road Holding Position Marking
7. Enhanced Taxiway Center Line

C. Marking in the parking landing (apron) consisting of:


1. Apron Safety Line Marking.
2. Apron Lead In and Lead Out line Marking
3. Apron Stop Line Marking
4. Apron Edge Line Marking
5. Parking Stand Number Marking
6. Aerobridge Safety Marking
7. Equipment Parking Area Marking
8. No Parking Area Marking
9. Service Road Marking

29
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Marking Movement for Aircraft


A. Runway Marking.
1. Runway Side Stripe Marking
a) Is a white line along the edge, beginning to the end of the runway.
Consists of one uninterrupted solid lines that have the same width
and spacing equal to the width of the solid line. Form a solid line /
single at the beginning and end of the runway
b) Function as marking the edge of the runway
c) The location along the edge of the runway.
d) Dimensions (width of the runway 30 meters
Width = 0.90 Runway Marking Designation

2. Runway Designation Marking


A runway designation marking shall be in white color consist of a two-
digit number shall be the whole number nearest the one-tenth of the
magnetic North when viewed from the direction of approach. When the
above rule would give a single digit number, it shall be preceded by a
zero.
a) Its function is to Cleanly identify and indicate the magnetic
orientation of the runway used for take-off and / or landing.
b) The numbers drawn are 12 m from the top threshold marking and
the first runway center line marking.
c) Dimensions : High number = 9 meters

Picture: Runway Marking Designation

3. Threshold Marking - Color: White


a) A threshold marking shall be provided at the threshold of a paved
instrument runway, and of a paved non instrument runway where
the code number is 3 or 4 and the runway is intended for use by
international commercial air transport.
b) A runway threshold marking shall consist of a pattern of longitudinal
stripes of uniform dimensions disposed symmetrically about the
centerline of a runway.
c) Its function is to Cleanly identify the beginning of a Runway.

30
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

d) The stripes of the threshold marking shall commence 6 m from the


threshold.
e) Dimensions:
 Number Stripes
 Landing Runway 45 meter width = 12 Stripes
 Stripe length = 30 meters
 Stripe Width = 1.8 meters
 Spacing between the stripes = 1.8 meters
 Spacing between the stripes on either side of the RWY centerline
= 3.6 meters
 Distance of the outer edge of the stripe to the edge of the runway
edge marking = 0.9 meters
 According to ICAO Annex 14, Para. 5.2.4.6,

Picture: Marking Threshold


LAYOUT MARKING
(SHEET 1/4)

1:5000
1:500 4. Runway Center Line Marking: Color - White NDOA-CDD-RW-MRK-100.0

a) A runway centre line marking shall be provided on a paved runway.


b) A runway centre line marking shall be located along the centre line of
the runway between the runway designation markings as shown in
ICAO Annex 14, Figure 5-2, except when interrupted by the Aiming
Point Marking.
c) A runway centre line marking shall consist of a line of uniformly
spaced stripes and gaps. The length of a stripe plus a gap shall be
not less than 50 m or more than 75 m. The length of each stripe shall
be at least equal to the length of the gap or 30 m, whichever is
greater.
d) Dimensions:
 Stripe width: Non-Precision Instrument = 0.45 meters
 Distance from beginning of first Stripe to beginning of each
Runway: 69 m
5. Aiming Point Marking
a) It is a sign on the runway consists of 2 (two) wide white stripe.
b) Function where the first wheel shows the aircraft is expected to touch
the runway during landing.
c) The dimensions can be seen in Table below.

31
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Landing Runway length


Location and Dimensions

2.200 m
Distance from threshold to
300 m
beginning of marking
Stripe length Recommendation: 45 - 60 m
Design: 45 m
Stripe Width Recommendation: 6 - 10 m
Design: 6 m
Lateral spacing between inner Recommendation: 18 – 22,5 m
sides of stripes Design: 20 m
Picture: Aiming Point Marking

6. Touchdown Zone Marking


a) It is a sign on the runway consisting of white lines in pairs, on either
side of the center line of the runway.
b) Function indicates the length of runway which is still available at the
time of landing.
c) It is symmetrical on either side of the center line of the runway.
d) The number of markers: 4 pairs
e) Since the RWY will only be 2200 m long, the scheme shown on ICAO
Annex 14, Fig. 5-5 A – Basic Pattern could be used to avoid too many
markings in so short distance.
f) Dimensions:
 Stripe length = 22.5 meters
 Stripe width = 3 meters
 Distance from Threshold of first marking pair = 150 meters
 The spacing between the inner sides of the touchdown markings
should be equal to the inner spacing of the Aiming Point marking
= 20 meters
 Because the aiming point marking is located at 300 m from
threshold, the order should be: 1 pair starting 150 m from
Threshold, aiming point marking at 300 m, followed by 1 pair at
450 m and the last pair at 600 m from threshold. As the second
pair coincides with the Aiming Point marking, it is to be omitted.

7. Runway Turn Pad Marking


Taxiway markings, runway turn pad markings and aircraft stand
markings shall be yellow. Where a runway turn pad is provided, the
runway side stripe marking should be continued between the runway and
the runway turn pad. Where a runway turn pad is provided, a runway
turn pad marking shall be provided for continuous guidance to enable an

32
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

aeroplane to complete a 180-degree turn and align with the runway


centre line. The runway turn pad marking should be curved from the
runway centre line into the turn pad. The radius of the curve should be
compatible with the maneuvering capability and normal taxiing speeds of
the aeroplanes for which the runway turn pad is intended. The
intersection angle of the runway turn pad marking with the runway
centre line should not be greater than 30 degrees. The runway turn pad
marking should be extended parallel to the runway centre line marking
for a distance of at least 60 m beyond the point of tangency where the
code number is 3 or 4, and for a distance of at least 30 m where the code
number is 1 or 2. A runway turn pad marking should guide the aeroplane
in such a way as to allow a straight portion of taxiing before the point
where a 180-degree turn is to be made. The straight portion of the
runway turn pad marking should be parallel to the outer edge of the
runway turn pad. The design of the curve allowing the aeroplane to
negotiate a 180-degree turn should be based on a nose wheel steering
angle not exceeding 45 degrees. The design of the turn pad marking
should be such that, when the cockpit of the aeroplane remains over the
runway turn pad marking, the Cleanance distance between any wheel of
the aeroplane landing gear and the edge of the runway turn pad should
be not less than those specified in 3.3.6 of ICAO Annex 14, sixth edition,
2013. For ease of maneuvering, consideration may be given to providing
a larger wheel-to-edge Cleanance for codes E and F aeroplanes. See
3.3.7 of ICAO Annex 14, sixth edition, 2013. A runway turn pad marking
shall be at least 15 cm in width and continuous in length. Taxiway edge
lights on a runway turn pad should be spaced at uniform longitudinal
intervals of not more than 30 m. The lights should be located as near as
practicable to the edges of the taxiway, runway turn pad, holding bay,
de-icing/anti-icing facility, apron or runway, etc., or outside the edges at
a distance of not more than 3 m.

B. Taxiway Marking
1. Taxiway Center Line Marking
a) It is a yellow line marking with a width of 0.15 meters
b) Function is to provide guidance to the aircraft from the runway to the
parking and vice versa.
c) A taxiway centre line marking shall be continuous in length except
where it intersects with a runway-holding position marking or an
intermediate holding-position marking as shown in ICAO Annex 14,
Figure 5-6.
d) Regarding the enhanced taxiway center line marking as prescribed in
5.2.8.4, 5.2.8.5, 5.2.8.9, 5.2.8.11 of ICAO Annex 14, sixth edition,
2013.

33
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

2. Runway-holding position marking


a) At an intersection of a taxiway and a non-instrument, non-precision
approach or take-off runway, the runway-holding position marking
shall be as shown in ICAO Annex 14, Figure 5-6, pattern A.
b) Its function as a sign for the aircraft to stop before obtaining
permission to enter the runway.
c) Dimensions:
 The width of solid lines and dotted lines = 0,15 meters
 The distance between the runway center line at the Landing
Runway holding position marking of a Instrument Non-Precision
Runway Approach = 75 meters

3. Taxiway Edge Marking


a) It is a double yellow colored stripe along the edges of the Taxiway.
The width of the lines and the gap between them shall be 0.15
meters.
b) Its function is to show the edge of the taxiway.

4. Taxiway Shoulder Marking


Taxiways, holding bays, and aprons are sometimes provided with paved
shoulders to prevent blast and water erosion. Although shoulders may
have the appearance of full strength pavement they are not intended for
use by aircraft, and may be unable to support an aircraft. Usually the
taxiway edge marking will define this area. Where conditions exist such
as islands or taxiway curves that may cause confusion as to which side of
the edge stripe is for use by aircraft, taxiway shoulder markings may be
used to indicate the pavement is unusable. Taxiway shoulder markings
are yellow.

5. Exit Guide Line Marking


a) It is a yellow line connecting the center line of the runway and the
centre line of taxiways to provide guidance to and from the runway
into or out of the taxiway.
b) At an intersection of a taxiway with a runway where the taxiway
serves as an exit from the runway, the taxiway centre line marking
should be curved into the runway centre line marking as shown in
Figures 5-6 and 5-26. The taxiway centre line marking should be
extended parallel to the runway centre line marking for a distance of
at least 60 m beyond the point of tangency where the code number is
3 or 4.
c) Dimensions:
 The length of the straight line after the tangent = 60 meters

34
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 The width of the gap between the runway center line and the
taxiway exit guide line = 0.9 meters
 The width of the exit guide line = 0,15 meters

6. Enhanced Taxiway Centerline


Taxiway centre line marking shall be provided on a paved taxiway, de-
icing/anti-icing facility and apron where the code number is 3 or 4 in such
a way as to provide continuous guidance between the runway centre line
and aircraft stands. Taxiway centre line marking should be provided on a
paved taxiway, de-icing/anti-icing facility and apron where the code
number is 1 or 2 in such a way as to provide continuous guidance
between the runway centre line and aircraft stands.Taxiway centre line
marking shall be provided on a paved runway when the runway is part of
a standard taxi- route and:
a. there is no runway centre line marking; or
b. Where the taxiway centre line is not coincident with the runway
centre line.
Where it is necessary to denote the proximity of a runway-holding
position, enhanced taxiway centre line marking should be provided.The
provision of enhanced taxiway centre line marking may form part of
runway incursion prevention measures.Where provided, enhanced
taxiway centre line marking shall be installed at each taxiway/runway
intersection. On a straight section of a taxiway the taxiway centre line
marking should be located along the taxiway centre line. On a taxiway
curve the marking should continue from the straight portion of the
taxiway at a constant distance from the outside edge of the curve.At an
intersection of a taxiway with a runway where the taxiway serves as an
exit from the runway, the taxiway centre line marking should be curved
into the runway centre line marking as shown in Figures below. The
taxiway centre line marking should be extended parallel to the runway
centre line marking for a distance of at least 60 m beyond the point of
tangency where the code number is 3 or 4, and for a distance of at least
30 m where the code number is 1 or 2.
Where taxiway centre line marking is provided on a runway in accordance
with Paragraph 5.2.8.3 in ICAO Annex 14, sixth edition 2013, the
marking should be located on the centre line of the designated taxiway.
Where provided:
a. An enhanced taxiway centre line marking shall extend from the
runway-holding position Pattern A (as defined in Figure Taxiway
markings) to a distance of up to 47 m in the direction of travel away
from the runway. See Figure See Figure Enhanced Taxiway Center
Line Marking (a).

35
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

b. If the enhanced taxiway centre line marking intersects another


runway-holding position marking, such as for a precision approach
category II or III runway that is located within 47 m of the first
runway-holding position marking the enhanced taxiway centre line
marking shall be interrupted 0.9 m prior to and after the intersected
runway-holding position marking. The enhanced taxiway centre line
marking shall continue beyond the intersected runway-holding
position marking for at least three dashed line segments or 47 m
from start to finish, whichever is greater. See Figure Enhanced
Taxiway Center Line Marking (b).
c. If the enhanced taxiway centre line marking continues through a
taxiway/taxiway intersection that is located within 47 m of the
runway-holding position marking, the enhanced taxiway centre line
marking shall be interrupted 1.5 m prior to and after the point where
the intersected taxiway centre line crosses the enhanced taxiway
centre line. The enhanced taxiway centre line marking shall continue
beyond the taxiway/taxiway intersection for at least three dashed
line segments or 47 m from start to finish, whichever is greater. See
Figure Enhanced Taxiway Center Line Marking (c).
d. Where two taxiway centre lines converge at or before the runway-
holding position marking, the inner dashed line shall not be less than
3 m in length. See Figure Enhanced Taxiway Center Line Marking
(d).
e. Where there are two opposing runway-holding position markings and
the distance between the markings is less than 94 m, the enhanced
taxiway centre line markings shall extend over this entire distance.
The enhanced taxiway centre line markings shall not extend beyond
either runway-holding position marking. See Figure Enhanced
Taxiway Center Line Marking (e).

36
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Enhanced Taxiway Center Line Marking

37
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Taxiway Lighting

38
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

C. Airport DVOR/DME

Application
When a VOR aerodrome checkpoint is established, it shall be indicated by a
VOR aerodrome checkpoint marking and sign.
Location
A VOR aerodrome checkpoint sign shall be located as near as possible to the
checkpoint and so that it is visible from the cockpit of an aircraft properly
positioned on the VOR aerodrome checkpoint marking.

Example for DVOR Marking

Characteristics
A VOR aerodrome checkpoint sign shall consist of an inscription in black on a
yellow background.

Recommendation
The inscriptions on a VOR checkpoint sign should be in accordance with one
of the alternatives shown above which:
VOR is an abbreviation identifying this as a VOR checkpoint:
116.3 is an example of the radio frequency of the VOR concerned;

39
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

147° is an example of the VOR bearing, to the nearest degree, which should
be indicated at the VOR checkpoint, and 4.3 NM is an example of the
distance in nautical miles to a DME collocated with the VOR concerned.
Tolerances for the bearing value shown on the sign are given in ICAO Annex
10, Volume I, and Attachment E. It will be noted that a checkpoint can only
be used operationally when periodic checks show it to be consistently within
±2 degrees ofthe stated bearing.

D. Apron Marking
1. Apron Lead-in and Lead-out line marking
a) Is the yellow line in the parking landing with a width of 0.15 meters.
b) Its function as a guideline used by aircraft taxiing from landing to
take-off parking circuited or vice versa.
c) It is in the Apron area.

2. Aircraft Stop Line Marking


a) It is a sign of a yellow stripe or bar
b) Its function as a stop sign where aircraft are parked.
c) Its on-off parking area, on the extension of the lead-in is 6 meters
from the end of the lead-in line.

3. Parking Apron Edge Line Marking


a) Double yellow stripe along the edge of the Apron.
b) Its function is to show off the edge of the apron boundary.
c) The apron edge line marking must be identified by 2 continuous
yellow lines 0.15 m wide, spaced 0.15 m apart.

4. Parking Stand Number Marking


a) It is a sign in the parking lot off in the form of letters and numbers
that are yellow with black background
b) Function shows the number of aircraft parking place.
c) It is in the area off the parking lot.

5. Service Road Marking


a) It is a sign of two (2) lines parallel as the boundary side of the road
and the dotted line as a guide axis of the road, white with a line
width of 0.15 meters.
b) The function limits the right and left which allows the movement of
equipment (GSE) separated by air.
c) It is in the area off the parking lot.

40
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

4.20. Airside Pavements

Calculation of pavement thickness of runway and taxiway is referred to


FAA(Federal Aviation Administration). FAA is a institution state of America who
regulates all things relating with aviation and navigation in America. FAA issued
a calculation regulation of runway design for airport namely Advisory Circular
(AC) No.150_5320_6D called as manual system and Advisory Circular (AC)
No.150_5320_6E using software FAARFIELD (Federal Aviation Administration Rigid
and Flexible Iterative Elastic Layered Design). Basically, the difference between
these two regulations is Advisory Circular Method (AC) No.150_5320_6D that the
determination of the pavement thickness refer to the design of aircraft characteristic using
graphic of pavement thickness of runway, whereas Advisory Circular (AC) method
No.150_5320_6E could determine the pavement thickness for all types of aircraft
by using FAARFIELD software.

The meaning of Designing Procedure of software is to produce Design Standard


of Thickness for Airport Pavement. FAARFIELD based on the concept of
Cumulative Damage Factor (CDF), where the contribution of the individual
aircraft to be analyzed separately at the moment of total damage.

Several concept in the FAARFIELD program namely;

1) Internal aircraft‘s data of FAARFIELD program divided into 6 groups of aircraft:


Generic, Airbus, Boeing, Other Commercial, General Aviation and Military.
Designer has sufficient choice in making determination and justification the
aircraft load and frequency.
2) Pavement to be designed to anticipate the load of maximum takeoff or MTOW
(Maximum Take-Off Weight). The Designing Procedure to be assumed 95% from
the gross weight supported by the main landing axle and 5% to be supported at
the aircraft nose axle. FAARFIELD recommended the using of MTOW even though
it is conservative enough in designing. This condition supported – by neglecting
the traffic of the coming aircraft.
3) Configuration and type of axle indicates how the load of aircraft to be distributed
to the pavement and how the pavement responds to the said load. The following
table indicates the configuration of typical axle referring to FAA Order 5300.7,
Standard Naming Convention for StandardConfiguration of Landing Axle, see
table at the next page.
4) The wheel pressure are various based on the axle configuration, gross weight and
wheel size. The wheel pressure has significant effect to the tension of asphalt
layer compared to the subgrade. Wheel pressure above 221 psi (1,5 MPa) will be
safe on condition that the layer of pavement surface and foundation layer meet
the requirement of minimum thickness.
5) Prediction of annual departure in accordance to the type of aircraft is required in
pavement designing. Information of the operational aircraft could be seen in the
aircraft movement at the Planning of Main Airport.

41
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

6) FAARFIELD Program to be developed and to be calibrated in order to produce the


consistent thickness of pavement design by using the previous method based on
the composition of different aircraft compared with individual aircraft. Procedure
of FAARFIELD design could do various traffic analysis – by using the previous
method.
Determination on design aircraft no needed to operate FAARFIELD. Even, the
program for calculating the damage effect to the various aircraft individually. The
effect of aircraft damage to be summarized entirely with the miner rule. At the
moment Cumulative Damage Factor (CDF) reaching 1,0 the design condition is
already good.
7) The old design procedure compel the mix traffic to be converted to the single
design aircraft and all annual departure to be converted to the equivalent annual
departure in accordance with the design aircraft. The designed aircraft to be
determined by choosing an aircraft with the highest damage based on weight and
the number of the departure aircraft. The design procedure of FAARFIELD not to
convert the mix traffic to be departure equivalent to the designed aircraft.
FAARFIELD analyze the damage on the pavement for every aircraft and
determine the final thickness for the total damage cumulative. FAARFIELD
consider the placement of main axle of individual aircraft related to the structure
pavement axle line.
8) An aircraft moving on the pavement will be seldom return to the same line. At
the moment an aircraft moving through taxiway or runway, it will take some lines
on the pavement on certain point to receive maximum load. Ratio of the number
of lines against the maximum load per unit of pavement area called Pass-to-
Coverage (P/C) ratio. The easiest way to calculate the number of aircraft line on
the pavement, yet the number of coverages should be declined mathematically
based on the P/C ratio for every type of aircraft. In definition, one coverage
occur when one unit of pavement area receive maximum respond (tension for
rigid pavement, tense for flexible pavement) due to certain aircraft. .
For the flexible pavement, coverages area to be assessed as a number of
maximum tense repetition occur on the ground. On the rigid pavement,
coverages area to be assessed as the number of repititious maximum tension
occur under the concrete slab.
Coverage produced from the operation of various aircraft is a function of the
number of aircraft route, number and space between wheels on the land wheel
axle, contact area, and spreading of lateral of relative wheel trail against the line
of pavement axle or indicating mark. In the calculation of P/C ratio, FAARFIELD
use the concept of effective wheel width. On the rigid pavement, the width of
effective wheel has a definition on the pavement surface and same with the
contact width of nominal wheels. The flexible pavement, for the collapse of tense
occur on the subgrade layer, the effective width has definition on above the
subgrade. Responses line drawn as a slant 1 : 2 from the edge of contact up to
the top of the ground as illustrated in figure 1 and figure 2. Wheel to be

42
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

considered as a separate condition or combination depend on the overlap


response lines. Figure 3.1 andfigure 3.2 just for information. All width calculation
of effective wheels and P/C ratio to be done in FAARFIELD program.

Figure 1. Two Effective Tire Width-Without Overlap

Figure 2. One Effective Tire Width-Overlap

9) Pavement designing of runway dan taxiway of airport using FAARFIELD just to


consider the traffic departure and to neglect the arrival at the moment of the
determination of the number of aircraft lines. As in the case of the arrival of an
aircraft at the airport is significant heavy compared at the moment of taking off
due to the consumption of fuel. FAA make a definition on Traffic Cycle (TC)
standard as once take off and once landing for the same aircraft. In the condition
described above, one TC produces one aircraft line - produced Pass-to-Traffic
Cycle (P/TC) ratio same with 1 (one). To determine the annual departure in
relation with the pavement designing – by multiplying the number of aircraft
departure with P/TC. Almost of all pavement designing, the P/TC value amounts 1
could be applied.
In the case of the heavy landing not quite different with the heavy of taking off or
when the aircraft should move through the pavement more than one time, it is
more accurate to justify the number of the annual departure applied in the
pavement designing to indicated the difference of P/TC ratio.
As an example, in the runway case with central taxiway configuration an aircraft
should fly through runway on the larger part at the moment of manuver to the
taxiway.

43
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

In this case an aircraft should take two times during the take off operation.
In this scenario the P/TC ratio with the amount of 2 should be used (with the
assumption that the aircraft fill the fuel at the airport), the number of annual
departure to be applied in the design should be better to be increased to factor 2.
10) In FAARFIELD, designing for fatigue called as Cumulative Damage Factor (CDF)
using Miner rule. CDF is the number of fatigue age of the pavement structure
which has already been used. An expression as a comparison of the applied load
and the permission load. For the single aircraft and the annual departure of the
CDF constant could be written as follows;

Or

Or

Pavement Condition on Several CDF Value

CDF Value Pavement Remaining Life

1 The pavement has used up all of its fatigue life

<1 The pavement has some life remaining, and the value of CDF
gives the fraction of the life used

>1 The pavement has exceeded its fatigue life

MATERIAL OF PAVEMENT STRUCTURE


Type of pavement structure for the designing work of Specified Technique of
North Side of Airport is fleksible pavement for runway pavement and taxiway.
Pavement construction work in the form of runway with its dimension is 2.200 x
45 m, turning pad construction using structure type of flexible pavement.
Flexible pavement consists of surface layer of hot mix on the layer of base
course, and in case needed due to the condition of ground base so subbase
course to be used. The entire of the said pavement structure composition fully
supported by subgrade.

44
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

1. Layer of Hot Mix Asphalt (HMA).


The wearing course and should prevent entering the water surface into the
foundation layer, and to provide smooth layer, fully free from particle causing
danger to aircraft and human. Also resist the tension due to the load of aircraft
wheel and not cause the worn out of the wheel. The surface layer should be
composed of agregat mix and bound asphalt producing a surface with uniform
texture having stability and maximum durability.

2. Foundation Layer
This layer is an essential structure component for the flexible pavement. This
layer has its main function for spreading the wheel load to the under part of the
pavement layer namely base course and subbase course, and/or the subgrade.
This foundation should have quality and thickness sufficient for preventing land
from collapse. The quality of the foundation layer depends of composition,
physical character and compacting the specification related with

Component, gradation, manipulation control and preparation all various


foundation material used at the airport for the load of 30.000 lbs (13.608 kg) or
more as follows;

a. Item P-208 – Aggregate Base Course


b. Item P-209 – Crushed Aggregate Base Course
c. Item P-403 – HMA Base Course

The use of the type of P-208 as a limited foundation material for pavement
designed for gross weight load ≤ 60.000 lbs (27.216 kg). If the type of P-208 to
be used as a foundation layer, so the minimum thickness of the hot mix asphalt
should be increased to 5 (127 mm).

The use of the type of P-209 as a limited foundation material for pavement
designed for gross weight load ≤ 100.000 lbs (45.359 kg).

The function of sub base course foundation layer is similar with the layer of base
course. But, considering that the position is far from the surface and with the
load intensity lighter, the material requirement not so tight like the foundation
layer. The specification relating with the component quality, gradation,
manipulation control and preparation of various types for sub base course used at
the airport for the designed load ≥ 30.000 lbs (13.608 kg) as follows;

a. Item P-154 – Subbase Course

All materials suitable for the foundation layer could be used too as sub base layer
in case of economical and practical condition if requested.

DESIGN DATA OF PAVEMENT STRUCTURE

For designing of pavement structure to be applied the designing data as follows;

45
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

1. Aircraft Movement

Type of aircraft to be used as aircraft movement is an aircraft of the kind of


B737-800 with 3.600 operation per annum and aircraft A330 with 300 operation
per annum also aircraft Dual Wheel 50 with 300 operation per annum. Aircraft
A330 is an aircraft where the movement has its largest contribution to the
pavement structure.

2. Improved Subgrade CBR Value

From the result of soil test indicate that the soil at the location of airport could be
used as a subgrade for pavement, but the soft soil of the surface minimum 0,2 m
depend on site condition advised to be peeled off and changed with better soil.

Table 2.CBR Value and Type of Application

CBR Value Qualification Assessment Applied

0–3 Bad Subgrade

3–7 Bad till moderate Subgrade

7 – 20 Moderate Subcase

20 – 50 Good Base, Subcase

> 50 Excellent Base

Source: the Asphalt Handbook, the Asphalt Institute, 1970 chapter 5

CBR value usually to be used for indicating the soil quality, bearing capacity, and
its function as foundation layer or as subgrade under the pavement or another
function of a kind at the airport area.

To determine the pavement thickness, the CBR value should be taken as a


reference in deciding the thickness of the foundation layer of the pavement
construction by considering the aircraft‘s load later will be operated on and over
the pavement. To achieve the said CBR value, besides the soil should be
compacted to gain the optimal density also needed checking on the level of
density of each certain distance (specification) during the work execution.

Value of bearing capacity of subgrade to be stated with the volume of the CBR
value. Value of CBR of subgrade applied is CBR soaked. The result of the soaked
CBR produced is relative good. CBR existing subgrade value in runway, taxiway
and apron using CBR soaked 8 %. If soil area with the soaked CBR value less
than 8 % should be done an improvement so that the improved CBR could
achieve the CBR value at minimum 8 %. The embankment 60 cm laying at upper
existing ground using sandy gravel material with CBR soaked 35 % to achieve
CBR soaked 20 % as subgrade improvement. Using the Boussinesq equation we
can calculate the improved subgrade CBR value.

46
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Table 3. Improved Subgrade CBR

IMPROVED SUBGRADE SOAKED CBR VALUE

Existing Subgrade soaked CBR = 8.00 %

- CAPING LAYER = 60.00 Cm

- Combination soake CBR


3
(h1 x CBR11/3) + (h2 x CBR21/3)
=
(h1 + h2)

CBR1 (%) = 35.00 h1 = 60 cm ( Uncrushed Aggregate / Sandy Gravel )


CBR2 (%) = 8.00 h2 = 40 cm ( Existing Subgrade )

CBR Design (Combination) = 21.08 %

For subgrade improvement should be done layer by layer with quality control of
density using Sand Cone Method.For information, to meet the required quality of
material a site survey should be done to look for the material which meets the
requirement of the specification and it has already been tested at the laboratory.

Besides to get accesbility easily and material deposit as an individual


consideration to guaratee that the project could run efficiently. Whereas the
quality of execution is strongly affect the final result when the execution not
supervised accurately in accordance with the designing specification resulting
degenerative acceleration to the said pavement structure.

Material to be applied for the structure of the flexibility pavement should meet
to the type of aircraft to be served and related to the weight of aircraft and
movement frequency.

For the thickness design of pavement layer, type of material to be converted with
the equivalent factor.

Table 3. Equivalent Factor for Sub Base Course

Material Equivalent Factor


Bituminous Surface Course 1,7 - 2,3
Bituminous Base Course 1,7 - 2,3
Cold Laid Bituminous Surface Course 1,5 - 1,7
Mix in-place Base Course 1,5 - 1,7
Cement Treated Base Course 1,6 - 2,3
Soil Cement Base Course 1,5 - 2,0
Crushed Aggregate Base Course 1,4 - 2,0
Gravel Sub Base Course 1

Source: Aerodrome Design Manual Part 3 Pavements

47
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Table 4. Equivalent Factor for Base Course

Material Equivalent Factor


Bituminous Surface Course 1,2 - 1,6
Bituminous Base Course 1,2 - 1,6
Cold Laid Bituminous Surface Course 1,0 - 1,2
Mix in-place Base Course 1,0 - 1,2
Cement Treated Base Course 1,2 - 1,6
Soil Cement Base Course N/A
Crushed Aggregate Base Course 1
Gravel Sub Base Course N/A

Source: Aerodrome Design Manual Part 3 Pavements

CALCULATION THICKNESS OF PAVEMENT STRUCTURE

Runway pavement structure design isused type of flexible pavement, and the
critical air craft is A-330. The flexible pavement structure calculation of
pavement structure is as follows:

1. Input Data Software FAARFIELD

a. Input Subgrade support condition

For subgrade condition, the data of CBR value is needed.

b. Material properties of each layer, covering:

Thickness of modulus for layer. Poisson‘s Ratio (has already been


determined in the software FAARFIELD)

c. Traffic, consisting of:

Aircraft characteristic covering of wheel load, wheel position and wheel


pressure.

d. Design Life

Designing of FAA standard for pavement based on the live time of 20 years
design life, computer program could be used for the other design life.

2. In the FAARFIELD program there are already several data of the type of
aircraft
3. Determination on the number of the annual departure relating with the
landing wheel.

For each to be input manually into the program for the number of various annual
departure of individual aircraft.

Parameters used for designing the thickness of construction of flexible pavement


as follows:

48
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

1. The largest aircraft

The type of aircraft to be used is the largest aircraft at the Oecusse airport is
A330-300 at this moment.

2. CBR value

The value of the supporting subbase stated with the CBR value of subgrade
used for design is 20% minimum for runway and taxiway. When there is soil
surrounded with CBR less than 20% should be done treatment.

The number of aircraft movement or traffic volume will affect the thickness
volume of the pavement. Volume of the aircraft movement obtained from the
Term Of Reverence (TOR) analysis study of Oecusse airport.

Figure 3. Main Wheel Configuration of B-737-800

Figure 4. Main Wheel Configuration ofA330-300

49
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure 5. Aircraft Movement

Material structure of pavement to be suggested should adjust to the material


condition and Asphalt Mixing Plant (AMP) condition at the location of airport as
follows:

Layer Material
Surface Course AC-BC + AC-WC
Base Course Crushed Aggregate CBR soaked
Sub Base ≥ 100 %
Course Uncrushed Aggregate CBR
soaked ≥ 35 %

Stabilized base and subbase course are necessary for new pavements designed to
accommodate jet airplanes weighting 100.000 pounds (45.359 kg) or more.
Exceptions (non standard structure) to the policy requiring stabilized base and
subbase may be made on the basis of superior materials being available, such as
materials with CBR soaked minimum of 100 % for base and 35 % for subbase.

Figure 6. Output of FAARFIELD

From the calculation using FAARFIELD program, the thickness of the pavement
structure of runway and taxiway could be determined as minimum as follows:

50
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

1) Surface Course : HMA = 120 mm


2) Base Course : Crushed Aggregate = 371,6 mm
3) Sub Base Course : Uncrushed Aggregate = 101,6 mm
4) Embankment : Sandy Gravel ≥ 600 mm, CBR soaked ≥ 35 %
5) Existing Ground : CBR soaked ≥ 8 %

After considering the execution condition, so the pavement structure of runway


and taxiway to be applied:

1) Surface Course : HMA = 120 mm (AC-BC = 70 mm, AC-WC = 50 mm)


2) Base Course : Crushed Aggregate = 380 mm, CBR soaked ≥ 100 %
(P-209)
3) Sub Base Course : Uncrushed Aggregate = 150 mm, CBR soaked ≥ 45%
(P-208)
4) Embankment : Sandy Gravel ≥ 600 mm, CBR soaked ≥ 35 %
5) Existing Ground : Soaked CBR soaked ≥ 8 %

Tact Coat 1 kg/m2 AC-WC = 5 cm


AC-BC = 7 cm
Prime Coat 2 kg/m2

Crushed Aggregate/Base Course =


38 cm, CBR soaked ≥100%

Uncrushed Agg/Sub Base Course =


15cm, CBR soaked ≥45 %

Embankment ≥ 60 cm

Existing Ground

Figure 7. Pavement Structure of Runway and Taxiway

PCN CALCULATION

PCN calculation using program COMFAA. COMFAA has already provided several
types of aircraft including the technical data prepared at the said library program.
For aircraft not mentioned in the COMFAA library so we have to look for the
information of the said technical data of aircraft later to be included into COMFAA
later program will calculate by itself the value of PCN of the said aircraft. The
stage of PCN calculation by using COMFAA as follows;

51
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Equivalent thickness = 24.2 in = 614.68 mm

Figure 8. Equivalent Thickness

Figure 9. Input ProgramCOMFAA

52
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure 10.Output PCN Value

PCN value of Pavement Structure of Runway = 120/F/A/W/T

Greater than 57 (ACN value of A330-300 at subgrade strength A)

THICKNESS OF PAVED SHOULDER

Determination on the pavement thickness of Shoulder using Software FAARFIELD

1. Input data software FAARFIELD

a. Input subgrade support condition

For subgrade condition, needed the data of CBR value

b. Material properties of each layer


c. Traffic, covering;
d. Design life, FAA designing standard for pavement based on the 20 – year
designing of lifetime.

2. Input of Aircraft Type

Aircraft movement to be input is an aircraft giving the largest value of


Cumulative Damage Factor (CDF).

3. To determine the Annual Departure in relation with the landing wheel. The
aircraft movement to be input in the program for the number of annual
departure is only for one unit aircraft per annum.

53
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure 11. Output Paved Shoulder Structure

From the calculation using FAARFIELD program so that the thickness of the
pavement structure of paved shoulder at minimum:

1) Surface Course : HMA = 101.6 mm


2) Base Course: Crushed Aggregate = 203.2 mm
3) Sub Base Course : Uncrushed Aggregate = 101,6 mm
4) Embankment : Sandy Gravel soaked ≥ 600 mm, CBR soaked ≥ 35 %
5) Existing Ground : CBR soaked ≥ 8 %

After considering the execution condition so that the pavement structure of paved
shoulder to be used;

1) Surface Course : HMA = 100 mm (AC-BC = 50 mm, AC-WC = 50 mm)


2) Base Course: Crushed Aggregate = 200 mm, CBR soaked ≥ 100 % (P-209)
3) Sub Base Course : Uncrushed Aggregate = 150 mm, CBR soaked ≥ 45 %
(P-208)
4) Embankment : Sandy Gravel soaked ≥ 600 mm, CBR soaked ≥ 35 %
5) Existing Ground : Soaked CBR soaked ≥ 8 %

Tact Coat 1 kg/m2 AC-WC = 5 cm

AC-BC = 5 cm
Prime Coat 2 kg/m2

Crushed Aggregate/Base Course = 20 cm,


CBR soaked ≥ 100%

Uncrushed Agg/Subbase Course = 15 cm, CBR


soaked ≥ 45%

Embankment ≥ 60 cm

CBR soaked ≥ 35%

Existing Ground

Figure 7. Pavement Structure of Paved Shoulder

54
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

END RUNWAY STRIP (ERS) AND RUNWAY END SAFETY AREA (RESA)

Basically ERS and RESA have main function as a safety area, in case there are
overshoot/undershoot aircraft. ERS and RESA should have surface that can slow
down or even stop the overshoot/undershoot aircraft.By considering the
execution condition so that the pavement structure of ERS and RESA to be used;

1) Stopper : Local Soil or sandy material = 150 mm


2) Embankment :Compacted Sandy Gravel, height is variable.
3) Local Soil

Local Soil or sandy


material= 15 cm

Embankment, height is
variable

Existing Ground

Figure 8. Pavement Structure of ERS and RESA

RUNWAY STRIP

Runway Strip have main role as safety area to protect the aircraft from any
obstacle and also to place some navigation aids instruments such as Airfield
Lighting (AFL), Precision Approach Path Indicator (PAPI), etc.By considering the
execution condition so the composition for Instrument Runway Strip will be:

1) Surface : Sandy Gravel, from Runway Shoulder Edge until Airside Drainage.
From Airside Drainage until edge of Instrument Runway Strip will be as
existing condition.
2) Existing Soil with 15 cm thickness on top level.

ANALYSIS OF THE STRUCTURE OF APRON PAVEMENT

Basically, the function of apron is a parking area for the aircraft also for loading
and unloading from and to the aircraft. For apron designing the following items
should be noted;

- Terminal configuration and free space dimension for safety and passenger‘s
protection against the propeller mash, blast, heat and noise.

- Charateristic of movement of aircrarft type to be served

55
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

- Type and size of GSE (Ground Service Equipment) facility and its maneuver.

- Condition of apron topography where the slope of apron should be greater


than 0.1%, to prevent from water stagnant at the apron.

But, the apron slope should not be allowed too much bigger as it could affect the
movement of the aircraft during the parking moment.

For the designing concept of the new apron using construction structure of rigid
pavement consisting of the design of the thickness of rigid pavement with its
volume and the said parameter such as:

a. Aircraft Movement

Type of aircraft to be used as critical aircraft is an aircraft with its largest


contribution to the pavement structure. The composition of the aircraft‘s wheel
also affect to the structure analysis of pavement.

b. Weight of the Critical Aircraft

Weight of the critical aircraft to be served is the type of aircraft which may
cause the largest load to the pavement structure and needed the largest
thickness of pavement.

c. Modulus Subgrade Reaction

Modulus of the reaction of subgrade resulted from the Plate Bearing test, but
value of the modulus subgrade reaction also could be determined by the value
of CBR by the method of formula correlation.

Based on the following correlation with the value of CBR 20 % (improved


subgrade), the value of Modulus Subgade Reaction calculated using this
formula below.

Modulus of the reaction of subgrade resulted from the Plate Bearing test, but
value of the modulus subgrade reaction also could be determined by the value
of CBR by the method of converting of graph.

Based on the formula above with the value of CBR 20 %, as a result the
value of Modulus Subgade Reaction to be242.55 lb/in = 65.8395 MN/m3.
3

d. Volume of Aircraft Movement

The number of aircraft movement or volume of traffic will affect the thickness
of pavement. The Volume of aircraft movement resulted from the equivalent
analysis of annual departure.

56
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

e. Concrete Quality

Concrete flexural strength or modulus of rupture (fr) strongly affect to the


thickness of the rigidity of pavement. Concrete flexural strength affected by
the quality of slab concrete to be used. The air field of Oecusse using the
quality of concrete slab with compressive strength fc‘= 29.05 MPa.

Concrete Flexural Strength fr = 0,75 fc'


= 0,75 29,05
= 4,04 MPa
= 585,95 psi
The strength of concrete flexural Strength after 90 days = 1,05 x 585,95 psi =
615.25 psi.

Design of structure of apron pavement based on the data of the result of


forecast calculation or the assessment of annual aircraft movement as a result
to be design as follows;

Aircraft to be design : A330-300


Maximum Take Off Weight : 507.062 lbs.
Wheel Configuration : Dual Tandem
Modulus Subgrade : 242.55 pci
Concrete Flexural Strength : 615,25 psi = 4.242 MPa

Based on the FAARFIELD output, as a result the total of slab of apron concrete
= 403.9mm. We take = 42 cm.

Figure 9.Aircraft Movement on Apron

To guarantee the uniformity of the strength of the pavement foundation under


the concrete slab, there is lean concrete (Rubblized PCC) with its thickness 10
cm, and the lean concrete layer supported by uncrushed aggregates layer.

57
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure 10.Output of Apron Rigid

The composition of the structure of apron pavement as follows;

Concrete Slab fcube = 350 kg/cm2


42 cm
(fr =44.4 kg/cm2)

Lean Concrete = 10 cm 10 cm
Fcube = 125 kg/cm2

SubBase≥ 15 cm, CBR soaked  45 ≥15 cm


%

The thickness of concrete slab 42 cm, maximum joint distance to be


recommended in accordance with FAA as follows :

Transversal = 20 feet = 6.1 m (to be applied = 5,0 m)

Longitudinal = 20 feet = 6,1 m (to be applied = 5,0 m)

f. Reinforcing Steel of Concrete Slab

Concrete slab shall be reinforced with deformed D 8 mm reinforcement quality


U–39 (fu = 3900 kg/cm2)

Reinforcement area needed :

3,7 xLx Lxt 


As1 =
fs

58
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

L = lane width

= 500 cm

= 16,40 feet

t = slab thickness = 42 cm

= 16,54 inch

fs= fu/SF (SF = 1,5)

= 2.600,00 kg/cm2

= 36.980,69 psi

As1=(3,7x16,40x√(16,40x16,54))/36.980,69

As1= 0,0270 in2/feet

= 0,5715 cm2/m

WxfxL
As2 =
2 xfs

W= weight of the slab (psf)

= 0,42 x 2400 (thickness = 42 cm = 0,42 m)

= 1008 kg/m2

= 206,46 lb/ft2(psf)

f= coefficient of resistance = 1,5

L= lane width

= 500 cm

= 16,40 feet

fs= fu/SF (SF = 1.5)

= 2.600,00 kg/cm2

= 36.980,69 psi

As2= (206,46 x 1.5 x 16,40)/2 X 36.980,69

= 0,0687 in2/feet

= 1,4542 cm2/m

Area of minimum reinforcing bar (As) required as follows:

As min = 0,05 % concrete area

= 0,05 % x 42 x 100

= 2,10 cm2/m

To be applied the reinforcing bar of deformed D 8 mmwith the As (reinforcing


area) = 50,24 mm2 = 0,5024 cm2

59
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

The number of minimum reinforcing bar per length = 2,05 cm 2/0,5024


cm2=4,1.

Distance of reinforcement = 100 cm / 6 pcs = 16,67 cm ≈ to be applied 15


cm

So that reinforcing bar of deformed D 8 mm @ 15 cm with area 3,35 cm2/m to


be applied.

g. soaked Dowel

Dowel is reinforcement on joint with its function as loading mover crossing


the connection such as crossing expansion joint and crossing contraction
joint.

FAA provides a list of size for dowel and its distance for various thickness of
concrete slab as follows :

Table 5. Size and Dowel Distance

Thickness of Concrete slab Diameter Length Distance

6-7 in (152-178 mm) ¾ in (20 mm) 18 in (460 mm) 12 in (305 mm)


7,5-12 in (191-305 mm) 1 in (25 mm) 19 in (480 mm) 12 in (305 mm)
12,5-16 in (318-406 mm) 1¼ in (30 mm) 20 in (510 mm) 15 in (380 mm)
16,5-20 in (419-508 mm) 1½ in (40 mm) 20 in (510 mm) 18 in (460 mm)
20,5-24 in (521-610 cm) 2 in (50 mm) 24 in (610 mm) 18 in (460 mm)

With the thickness of 42 cm concrete slab, so that size and dowel distance to
be recommended by FAA:

Diameter= 1 ¼ inch = 40 mm, diameter 32 mm to be applied.

Length= 20 inch = 51 cm ≈ 51 cm

Distance= 11.8 inch = 30 cm

So that Dowel D 32 @ 30 cm, length 51 cm to be applied.

Calculation :

Area of 40 mm dowel = 1,256 mm2

Area of 32 mm dowel = 803.84 mm2

Requered = 1256/803.84 = 1.56

Distance = 460/1.56 = 294,9 mm ≈ 30 cm

60
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure 11. Typical Apron Rigid Pavement

Sealant and Joint Filler

Sealant used for each connection to prevent from entering water and
unusual thing into the connection. Filling material which is compressible and
pre molded to be used for expansion connection so that expansion can be
taken on the slab. Sealant on connection to be applied on the surface of
filling material to prevent from entering the water or other unusual thing.
For area to be used for filling fuel, sealant resist to fuel should be used.

4.21. Airside Roads


TRAFFIC LOAD
Traffic load is required for the road technique design, because the road capacity
which will be designed depends on the composition of traffic load later will be
used.
To determine the thickness of the road pavement structure, the average daily
traffic (ADT) to be calculated based on the criteria and assumption. In designing
the daily traffic for individual road is different as the type of vehicle passing the
said road are various. For inspection road the type of vehicle passing the said
road consisting of passenger vehicle, inspection vehicle and fire fighting vehicle
and ambulance vehicle.

61
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

GRADING AREA
Grading area to be executed at the road design area in the form of compacted
soil and leveled soil with various slopes in accordance with the requirement. The
surface of grading area should able to flow the rainy water (the surface water) to
the drainage so that there is no water pounding at the grading area.
Height of surface plan (leveling) is based on the volume of excavation and
embankment as small as possible, and therefore able to minimize construction
costs but still meet the requirements of the drainage system by taking into
account the maximum flood water level.
The following items should be considered in the leveling design;
a. No flood or water pounding at the road facilities and other facilities during the
rainy season.
b. The surface of the existing soil and most of the part of the design land has
various elevations from the lowest one till the highest against the average of
surface of sea level (mean sea level).
c. In order to reduce the volume of the soil work (pile and excavation) and to
facilitate the drainage so the slope to be used at the surface of road
pavement with the slope 1 % and the road shoulder 2% - in repairing the
existing slope.
Determination on the height depends on some factors such as: the elevation
of the road design, drainage necessity, related with inter facilities, material
supply for piling and place for excavation discard and etc.

FLEXIBLE PAVEMENT PARAMETERS


Pavement for airside area road use flexible pavement type. Here are the
components used in road pavement design:
a. Regional Factor (RF)
Regional factor is affected by the form of alignment (slope and curve),
percentage of heavy vehicle and season (rainy season).
Based on the alignment path with a slope I (< 6%), percentage of heavy
vehicles ≤ 30% and type I climate (rainfall > 900 mm/year), then RF = 1.5
Table 1 - Regional Factor

Source: AASHTO 1993

b. Index of Pavement Surface (IPs)


Index of pavement surface (IPs) as a basic size in determining the value of
pavement in relation with the necessity of traffic. The Index of Pavement

62
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

surface indicating the average value/smoothness and the surface resistance


in relation with the improvement of service for the passing traffic.
With Equipment Single Axle Load (ESA) < 10 so as to obtain the value type
local road IPs = 1.5

Table 2 - Index of Pavement Surface

Source: AASHTO 1993

Coefficient of vehicle distribution passing the Ground Support Equipment


(GSE) road at Oecusse Airport, to be designed 2 lanes and two directions
consisting of;
1. Total weight < 5 ton (light vehicle) = 0.50
2. Total weight  5 ton (heavy vehicle)= 0.50

c. Index of Pavement Surface at Early (IPo)


Pavement surface layer is Asphalt Concrete (AC-WC) with the IPo = 3.5 to
3.9.

d. Vehicle Distribution Coefficient (C)


Coefficient of vehicle distribution for both light and heavy vehicles passing
the design route, planned for light vehicles = 0.5 (2 way, 2 lane) and for
heavy vehicles = 0.5 (1 way, 2 lanes).

Table 3 - Vehicle Distribution Coefficient

Number of Light Vehicle Heavy Vehicle


Lane 1 way 2 way 1 way 2 way
1 lane 1.00 1.00 1.00 1.00
2 lane 0.60 0.50 0.70 0.50
3 lane 0.40 0.40 0.50 0.475

Source: AASHTO 1993


e. Design Life and Traffic Growth of Road
Life time of road design is the number of time (in year) calculated from the
opening of the said road until at the moment it is required for heavy repairing
or to be assumed that new layer is needed. The life time of the road design
to be applied in this designing is 10 (ten) years.

63
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Traffic Growth taken based on the assumption of growth in passenger and


aircraft movements, the assumption of growth is 4%.

f. Planned Subgrade CBR


Bearing capacity of Subgrade (DDT) to be determined based on the
correlation graph between CBR and DDT (graph as per attached). Based on
the report of Soil Investigations on site showing the soil condition at location
or the existing soil is good enough. To design this pavement structure -
Design CBR value 8 % is to be applied. Soil settlement can cause problem at
the project area. Therefore one aspect of the soil improvement method
proposed in the soil improvement report is to limit the settlement that
probably will occur in this area.
In addition to settlement problem, the soil improvement method is also
focused on getting the CBR of subgrade of 8% which is required for
pavement design. It is assumed that for the worst condition the CBR of the
existing soil is less than 8%. Therefore, this CBR needs to be increased to
8% as required for the pavement design. Subgrade of the existing soil can be
improved by method remove and replace. This means that the upper of the
existing soil is removed and then replaced with good selected material. The
selected fill material is then compacted to at least 95% of its dry density. The
selected fill material at least canComponent Analysis Pavement be obtained
from the excavated materials from quarry area.

g. Component Analysis of Road Pavement


Planning calculation is based on the relative strength of each layer of the
long-term pavement, where the pavement thickness determination expressed
by the following formula:

ITP = a1D1 + a2D2 + a3D3

a1= relative strength coefficient of surface course


a2 = relative strength coefficient of base course
a3 = relative strength coefficient of sub base course
D1 = thickness of surface course
D2 = thickness of base course
D3 = thickness of sub base course

Figure 1 - Composition of the Flexible Pavement

64
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

h. Relative Strength Coefficient


In determining the composition of pavement used table 4 and table 5.

Table 4 - Relative Strength Coefficient

Source: AASHTO 1993

Source: AASHTO 1993

Table 5 - Limits of Minimum Thickness Pavement Layers

Source: AASHTO 1993

65
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

i. Equivalent Single Axel Loads


Equivalent Single Axel Loads each vehicle is determined by the following
formula

NumeralEquivalent SingleAxis 
SingleAxisLoad (kg )4
8160

Table 6 - Numeral Equivalent Single Axle Vehicles

Source: AASHTO 1993

Table 7 – Numeral Equivalent for Each Type of Vehicle

One Axis Load Numeral Equivalent


Load
Type of Vehicle
( kg ) Rear/ Rear/
Front Front Total
Behind Behind
Towing Tractor 15.000 7.000 8.000 0,5415 0,9238 1,4653
Fuel Truck 13.000 6.000 7.000 0,2923 0,5415 0,8338
Cargo Dolly Train 10.000 5.000 5.000 0,1410 0,1410 0,2820
Sweeper Car 2.000 1.000 1.000 0,0002 0,0002 0,0004
Truck Basin 10.000 5.000 5.000 0,1410 0,1410 0,2820
Source:Consultant Analysis

A. PAVEMENT DESIGN OF SERVICE ROAD AND GA PLATFORM


Characteristics of traffic in the area around and inside the airside area will be
divided into 3 (three) pavement types of the road. These roads are :
a. Service Road (GSE)
b. Emergency Road (Fire Fighting)
c. Perimeter Road

The Service road (GSE) in airside area is dominated by Towing Tractor, Fuel
Truckand Cargo Dolly Train, others vehicles are passenger car, firefighting
car and sweeper car. Characteristics of traffic on airside area base on the
traffic of passenger and aircraft movement per day. From the characteristic
movement of traffic will also determine pavement design parameters.

66
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

a. Types of vehicles that operate are at early of life time:


1. Light vehicles (2 ton) 984 vehicle/day
2. Towing tractor (15 ton) 14 vehicle/day
3. Fuel Truck (13 ton) 24 vehicle /day
4. Cargo dolly train (10 ton) 14 vehicle /day
5. Firefighting car (25 ton) 14 vehicle /day
6. Bus (8 tons) 200 vehicle / day

b. Configuring the vehicle axle load are :


1. Light vehicles 2 tons = (1+1) tons
2. Towing tractor 15 tons = (7+8) tons
3. Fuel Truck 13 tons = (6+7) tons
4. Cargo dolly train 10 tons = (5+5) tons
5. Firefighting 25 tons = (10+10+5) tons
6. Bus 8 tons = (5+3) tons

c. Equivalent single axle load are :


1. Light vehicles 2 tons (1+1) = 0.0004
2. Towing tractor 15 tons (7+8) = 1.4653
3. Fuel Truck 13 tons (6+7) = 0.8338
4. Cargo dolly train 10 tons (5+5) = 0.2820
5. Firefighting 25 tons (10+10+5) = 4.6520
6. Bus 8 tons (5+3) tons = 0.1593

Pavement for Service Road (GSE) use type of flexible pavement. Here are the
components used in road pavement design:

a. Regional Factor (FR)


Based on the alignment path with a slope < 6%, percentage of heavy
vehicles ≤ 30% and type I climate (rainfall > 900 mm/year), then RF =
1.5.

b. Index of Surfaces (IPs)


With Equivalent Single Axle load 10-100, so as to obtain the value of the
collector road type IPs = 2.0.

c. Index of Surfaces at Early Plan (IPo)


Planned type surface layer is Asphalt Concrete with the IPo = 3.9 to 3.5.

d. Vehicle Distribution Coefficient (C)


Planned for light vehicles = 0.5 (2 direction, 2 lane) and for heavy
vehicles = 0.5 (2 direction, 2 lanes).

67
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

e. Design life of road is 10 (ten) years

f. Traffic growth at 4 % per year


From subgrade CBR value 8 %, then DDT value 5.6 determined.

g. Design Traffic
 Equivalent Single Axle at initial of Design Life (LEP)
Light vehicles 2 tons = 0.0004 x 0.5 x 984 = 0.19
Towing tractor 15 tons =1.4653 x 0.5 x 14 = 10.43
Fuel Truck 13 tons =0.8338 x 0.5 x 24 = 9.89
Cargo dolly train 10 tons =0.2820 x 0.5 x 24 = 3.35
Firefighting 25 tons =4.6520 x 0.5 x 14 = 33.11
Bus 8 tons (5+3) tons =0.1593 x 0.5 x 200 = 15.93
Total = 72.91

 Equivalent Single Axle at end of Design Life (LEA)


Light vehicles 2 tons = 0.0004 x 0.5 x 984 =0.29
Towing tractor 15 tons =1.4653 x 0.5 x 14 = 15.44
Fuel Truck 13 tons = 0.8338 x 0.5 x 24 = 14.64
Cargo dolly train 10 tons = 0.2820 x 0.5 x 24 =4.95
Firefighting 25 tons = 4.6520 x 0.5 x 14 = 49.01
Bus 8 tons (5+3) tons = 0.1593 x 0.5 x 200 = 23.58
Total = 107.92

Design Traffic LER = (LEP + LEA)/2


= (72.91 + 107.92)/2
= 90.41

68
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

The composition of the flexible pavement thickness


ITP = a1D1 + a2D2 + a3D3
6.35 =0.3x 5 + 0.13x 15 + 0.11x D3
6.35 = 1.5 + 1.95 + 011x D3
D3 = (6.35 - 3.45)/0.11 = 26.36  Use D3 = 30 cm.
D1 =5 cm (AC-WC, MS ≥ 340 kg)
D2 = 15 cm (Crush Aggregate Base Course, CBR ≥ 80 %)
D3 = 30 cm (Sandy Gravel, CBR ≥ 30%)

Figure 2 - STRUCTURE PAVEMENT OF SERVICE ROAD

Figure 3 - Figure Nomogram Road of Service Road

B. PAVEMENT DESIGN OF EMERGENCY ACCESS (FIRE FIGHTING ROAD)


a. Types of vehicles that operate are :
1. Light vehicles (2 tons) 984 vehicle / day
2. Bus (8 tons) 200 vehicle / day
3. Firefighting car (25 tons) 14 vehicle / day

b. Configuring the vehicle axle load are :


1. Light vehicles 2 tons = (1+1) tons
2. Bus 8 tons = (5+3) tons
3. Firefighting 25 tons = (10+10+5) tons

69
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

c. Equivalent single axle load are :


1. Light vehicles 2 tons (1+1) = 0.0004
2. Bus 8 ton (5+3) = 0.1593
3. Firefighting 25 tons (10+10+5) = 4.6520

Pavement for emergency (firefighting road) use type of flexible pavement.


Here are the components used in road pavement design:

a. Regional Factor (FR)


Based on the alignment path with a slope < 6%, percentage of heavy
vehicles ≤ 30% and type I climate (rainfall > 900 mm/year), then FR =
1.5.

b. Index of Surfaces (IPt)


With Equivalent Single Axle load 10-100, so as to obtain the value of the
collector road type IPt = 2.0.

c. Index of Surfaces at Early Age Plan (IPo)


Planned type surface layer is Asphalt Concrete with the IPo = 3.9 to 3.5.

d. Vehicle Distribution Coefficient (C)


Planned for light vehicles = 0.5 (2 direction, 2 lane) and for heavy
vehicles = 0.5 (2 direction, 2 lanes).

e. Traffic growth at 4 % per year


From sub grade CBR value, then DDT value 5.6 determined.

f. Design life of road is 10 (ten) years

g. Design Traffic
 Equivalent Single Axle at initial of design life (LEP)
Light vehicles 2 tons (1+1) =0.0004 x 0.5 x 984 = 0.19
Bus 8 ton (5+3) =0.1593 x 0.5 x 200 = 15.93
Firefighting 25 tons (10+10+5) = 4.6520 x 0.5 x 14 = 33.11
Total = 49.23
 Equivalent Single Axle at end of design life (LEA)
Light vehicles 2 tons (1+1) = 0.0004 x 0.5 x 984 =0.29
Bus 8 ton (5+3) =0.1593 x 0.5 x 200 = 23.58
Firefighting 25 tons (10+10+5) = 4.6520 x 0.5 x14 = 49.01
Total = 72.88
Design Traffic LER = (LEP + LEA)/2
= (49.23 + 72.88)/2

70
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

= 61.06
h. The composition of the flexible pavement thickness
ITP = a1D1 + a2D2 + a3D3
5.85 = 0.3x 5 + 0.13x 15 + 0.11x D3
5.85 = 1.5 + 1.95 + 011x D3
D3 = (5.85 - 3.45)/0.11 = 21.82  Use D3 = 25 cm.
D1 = 5 cm (AC-WC, MS ≥ 340 kg)
D2 = 15 cm (Crush Aggregate Base Course, CBR ≥ 80 %)
D3 = 25 cm (Sandy Gravel, CBR ≥ 30%)

Figure 4 - Structure Pavement Of Fire Fighting Road

Figure 5 - Figure Nomogram Fire Fighting Road

C. PAVEMENT DESIGN OF PERIMETER ROAD


a. Types of vehicles that operate are :
Light vehicles (2 tons) 48 vehicle / day at early life
b. Configuring the vehicle axle load are :
Light vehicles 2 tons = (1+1) tons
c. Equivalent single axle load are :
Light vehicles 2 tons (1+1) = 0.0004

71
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Pavement for perimeter road use type of flexible pavement. Here are the
components used in road pavement design:

a. Regional Factor (FR)


Based on the alignment path with a slope < 6%, percentage of heavy
vehicles ≤ 30% and type I climate (rainfall > 900 mm/year), then FR =
1.5.

b. Index of Surfaces (IPt)


With Equivalent Single Axle load < 10, so as to obtain the value of the
local road type IPt = 1.0.

c. Index of Surfaces at Early Age Plan (IPo)


Planned type surface layer is Asphalt Concrete with the IPo = 3.9 to 3.5.

d. Vehicle Distribution Coefficient (C)


Planned for light vehicles = 0.5 (2 direction, 2 lane) and for heavy
vehicles = 0.5 (2 direction, 2 lanes).

e. Traffic growth at 1 % per year

f. From sub grade CBR value, then DDT value 5.0 determined.

g. Design life of road is 10 (ten) years.

h. Design Traffic
 Equivalent Single Axle at initial of design life (LEP)
Light vehicles 2 tons (1+1) = 0.0004 x 0.5 x 48
Total =0.0096

 Equivalent Single Axle at end of design life (LEA)


Light vehicles (2 tons) = 48*(1+0.01)10=53.0 vehicle/day.
=0.0004 x 0.5 x 53 = 0.0106
Total = 0.0106

Design Traffic LER = (LEP + LEA)/2


= (0.0096 + 0.0106)/2
= 0.0101

i. The composition of the flexible pavement thickness


ITP = a1D1 + a2D2 + a3D3
2.75 = 0.3x 0 + 0.13x 15 + 0.11x D3
2.75 = 0 + 1.95 + 011x D3

72
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

D3 =(2.75 - 1.95)/0.11 = 7.27  Use D3 = 10 cm.


D1 =0
D2 = 15 cm (Aggregate Base Course, CBR ≥ 80 %)
D3 = 10 cm (Sandy Gravel, CBR ≥ 30%)

Structure Pavement Of Perimeter Road

Figure Nomogram Perimeter Road

4.22. Ground Service Equipment


To adequate importance of flying operation an airport must need Ground Service
Equipment to support aircraft when they are on the ground. To fill the fuel,
charge electricity, and refuel clean water, throw out lavatory, and even take
passenger ladder. To be a good support, GSE vehicles need a shelter and a
workshop to cover and backup their works.

73
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

GSE EQUIPMENT Unit


Baggage/ cargo diesel tow tractor of drawbar pull capacity for 5.000
2
lbs for carrying cargo from and to airplane.
Close baggage carts for carrying passenger luggages, it will be
8
closed to keep luggages not getting wet because of rain.
Diesel pushback and tow tractor capable of handling in aircraft of
type Airbus A330-300 or equivalent with tow bars and head 1
equipment for Airbus, Boeing ERJ aircraft
Jet engine Air Start Unit capable of starting an A330-300 or
1
equivalent aircraft
Cleaning service cars for cleaning airplane passenger cabin 2
Lavatory service cart with 35 gallons waste tank capacity and
complete with adapters and fitting to pull out waste from the 1
aircraft
90KVA 400Hz AC/ 28V DC Ground Power Unit to recharge the
1
aircraft power
Passenger Stair Truck, 88-212‖ for passenger entering the aircraft
2
when jet bridge cannot used.
Caster Bed Pallet Trailer for 96‖ X 125‖ pallets and 6.800Kg weight 4
Support Vehicles for patrolling the airport via perimeter road and
2
pickup staff from and to service area

4.23. Rescue and Fire Fighting Services (RFFS) Facilities


Primary responsibility and objective of an RFFS and emergency service
organization is to provide a timely response, protect life and property, and
minimize the effects of an aircraft accident, incident, or catastrophic event
occurring primarily on airport property. The key to successful execution of this

74
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

role can be achieved by optimizing the location of the airport fire station (s) and
designing the station to enhance the effectiveness and efficiency of emergency
service personnel. Essential to operational efficiency is fire station site selection.
This critical element is paramount in reducing emergency response times to an
aircraft related incident. Response times can be further reduced by ensuring that
the facility‘s layout and floor plan provide a smooth and unimpeded flow of
personnel traffic to reach emergency response vehicles in the shortest period of
time possible. Fire station operations can be more efficient and cost-effective by
incorporating an overall station systematic design approach will result in a
process flow relationship of facility subsystems, e.g., mechanical, electrical, and
piping systems. Human factors engineering should promote personnel safety.The
airport should provide with a main fire station and should be equipped with
essential equipment and water supply reserves. The Fire Station has to provide a
high level of protection 24 hours of the day and seven days of the week if
necessary. The following consideration has been used for the dimensioning of the
facilities. There are recommendations, in order to provide adequate space for the
development of the facilities. These requirements shall be refined at a later stage
through the design development process.The recommended equipment
distribution between the mail and sub fire station is provided in table below.

RFFS EQUIPMENT (according to Scope of Airport Document)


Crash Fire Truck 2
Ambulance 1
Support Vehicles 1

75
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

The fire station will accommodate the alarm centre, fireman rest and recreational
areas, training areas, administration areas, manager‘s offices, workshops, storage
for spares and extinguishing agents. Accordance with ICAO Annex 14, chapter 9,
and the appropriate prevision of rescue and Fire Fighting Service (RFFS) facilities
will be made Oecusse Airport. The level of protection planned at the airport will be
category 6, although the forecast predicts that Category 7 could be operationally
viable. This is sufficient for the safe operation off all Code E aircraft for which the
airfield has been designed to support.For all categories of fire, crash, rescue
services, a minimum response time of two minutes, and not exceeding three
minutes should be achieved to the end of each runway and all movement areas in
optimum conditions of visibility and surface conditions. The response time is the
time between the first alarm call and the first effective intervention at the accident
site. This can often only be achieved by a rapid intervention vehicle.
Therefore, the location of the fire station it‘s centered and positioned at South to
the Runway location and West to the ATC and Passenger Terminal, according the
new development Master Plan for Oecusse Airport

4.24. Airport Fence

This fence is constructed with the PURPLE COLOR as a border of operational area
of airport for air side where the fence gate equipped with safety equipment. For
safety fence to be recommended the BRC fence with 2,5 m height from the soil
surface.

1. Security Fence and Security Fence Gate


 Security Fence :
Safety Fence constructed and installed around certain facilities, also for
special Safety Fence such as navigation equipment: DVOR and Fuel
Depot.
 Security Fence Gate :
In principal, the Safety Fence Gate to be located as a connection between
area of ground side facilities and air side – with its width suited to
theroad width. Also, to be located at the entrance to the facility area of
air side.

76
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

2. BRC Fence as Airport Security Fence :


BRC is abbreviation of British Reinforced Concrete – and it is a name of a
company from England. This company produces fence with specific shape,
where the point of the fence is bent in such a way like the shape of
triangular. In Indonesia this type of fence called BRC fence. BRC fence is
made of iron ready to be installed so that it is practical to be used. The
production process is that some pieces of iron wire to be welded – by using
wire mesh machine.
At first, sheet fence should be formed and later to be plated with galvanized,
so that guaranteed for its resistance against the danger of corrosion
On the BRC fence to be installed rectangle iron and iron wire with its size
suited to the drawing. The quality of fence steel and rectangle iron to be used
should be good one and could be testified through laboratory test, and to
meet the specification standard – with quality guarantee issued by the
factory ((factory certificate).

3. Terms of Fence Installation


 Type of foundation to be used for BRC fence is local foundation by
applying ready mix concrete foundation 1 cement: 2 sand and 3 gravel
equal to the quality of K175 concrete.
 The size of ready mix concrete foundation is 50 cm x 50 cm and 85 cm x
50 cm with its individual foundation height is 65 cm. This foundation to
be used for supporting pole for the entire foundation, placed on the heap
of sand (5 cm thickness) as the foundation base.
 To anticipate animal entering through under the BRC fence, so
longitudinal foundation is needed, and cultivated into the soil with its
depth 20 cm.
 BRC fence is made of iron material U50 plated with galvanize – by
0
applying hot deep (465 C) with its size suited to the drawing for
construction
 BRC to be used is the type of hot dipped galvanized, ASTM A153 and
factory product using machine.
 Iron fence pole with its length 2.950 m diameter 2‖ Hot Dipped
Galvanized. Pole and fence iron is cultivated with the depth of 50 cm into
the foundation of mix ready concrete foundation with its size mentioned
at item 1 above.
 Each pole cultivated into the ready mix concrete foundation should be
installed with anchors iron (2 bars), diameter 12 mm, and 15 cm length.
At the end point of each anchor should be bent.
 Supporting fence should be installed for each 7.5 meter horizontal
distance and to be installed alternately at each fence pole and at each
fence curve or at every turn fence.

77
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 On the BRC wire to be installed barbed wire with 19 cm height, and each
connection between irons should be locked with bolt. Whereas,
connection between fences iron pole and BRC could be locked with u-clip.
 Fence Dimension :
a. Steel Pole Diameter = 2 inches
b. Minimum distance of vertical wire = 80 cm
c. Minimum height of BRC fence = 2 meter
d. BRC fence length = 2.4 meter
Free space of fence both outside and inside the fence is 3.0 meter. Within
radius 3,0 meter outside and inside the fence no objects or trees should be
allowed.
NOTES:
1. Galvanized metal is anti-rust coating process or non-corrosive metal on
metal. Galvanized can also be identified from the color silver or bronze,
but not shiny or matte. Color is also often called dull silver.
2. For this level of thickness, galvanized had varying degrees of thickness.
Starting from 1 micron (thousandth of a millimeter) to 9 micron is also
even more. For a 4 micron thickness was usually the manufacturer will
provide a guarantee for 10 years anti-rust (3 years rust-free). Thus, the
higher the thickness, the higher the level of immunity to rust.
3. Hot dip galvanizing process has two kinds of ways. The first is Electro
Plating or a commonly abbreviated to EP. This process by giving the flow
of electricity in a galvanized tub. So that the particles stick to the
galvanized iron until the desired thickness. While the second process is
Hot Dip Galvanized (hot dipped galvanized) or a commonly abbreviated to
HD. The second process is by dipping into the pool galvanized iron hot.
The more often dyed its galvanize getting thicker layer.
4. Accessories BRC fence is the supplementary material than BRC fence. BRC
fence accessories consist of bolts, u-clip or clamp, lid pole / pipe cap or
knob.

78
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

5. AIR TRAFFIC SERVICES (ATS)


The ATC Tower designed by the requirements of the airport. For the effective provision of
Aerodrome Control Service, a Clean and obstructed view of the entire movement at the
airport and air traffic. The position and height of ATC Tower already have Clean sight
visibility to every inch of the airport and the surrounding airspace. The design of tower
have 360 degree overview, with central tower shaft with elevator, staircase and
redundant supply systems.

5.1. Airport Air Traffic Control Facilities


The facility at the ATC and Meteorology Office supports the following functions:
a. Visual Control Room (VCR)
b. Technical Equipment Room
c. Technical Supervision Room
d. AIS Office
e. Technical Workshop
f. Technical Stores
g. MET Facility
h. Standby UPS and dedicated standby diesel generator set located in the main
power house
i. Management and Administration Offices
j. Meeting and Training Rooms
k. Rest Room
l. Dedicated Car Park

5.2. Airport Air Traffic Control Complex (ATCC)


The ATC Tower also has Meteorology Services so it is fully capable for traffic
control services and to update weather condition and reported it to the airman. It
shall prepare and obtain forecasts and other relevant information for flights and
for local meteorological forecasting. It maintains a continuous survey of the
meteorological conditions at the airport as well as provides briefing, consultation
and flight documents to flight crew members and other flight operation
personnel. The information will be provided through an automated self-briefing
service.
There is 1 elevator in the building, appropriate for persons working in it. These
elevators provide a rapid access to and from the tower cabin and will be sufficient
to enable equipment to be moved around the building. Access to the roof in this
building will provide to permit essential maintenance to be carried out. The roof
structure is strong enough to accommodate necessary equipment that will be
positioned above the roof such as AC outdoor unit, antenna etc.
Fire escapes serving all floor, placed at each end of the building and provide at
least 1 hour fire protection. The fire alarm status will be positioned at the
entrance/reception desk on ground floor.

79
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

The tower crew eye elevation has to be Clean to all area of the aerodrome,
including from threshold to threshold. Below is the calculation for the minimum
eye elevation for the tower crew:

Ee = Eas + L x Tan (Gs + 35’)

Where:
Ee = Eye Controller Elevation
Eas = Farthest Threshold Elevation
L = Distance Tower Site to Farthest Threshold
GS = Angle from Farthest Threshold to Tower compare elevation Runway

From above formula, we get the minimum height of the eye controller elevation
is 25,41 m. So tower control height plus 2 meter (from the eye controller to roof)
and plus 1 meter (for the wall protection at the roof for antenna maintenance)
we get the optimum height of the tower is 28,41 m.To optimize the operation for
future development considers tower height should be 30 m.
Exterior glass will be treated in such a way to eliminate, to greatest extent
possible, the effects of strong sunlight within the building including blinds. The
building is sound proofed to reduce the noise of the aircraft. So the telephone
and other communication can be use. ATCT windows glass must comply with
credible International Standards for light transmissivity of no less than 84%, heat
transmission (U-value) of 1,00 maximum and free of parallax or other optical
distortion. FAA Order 6480 will be preferable. The window blinds(roll down – roll
up shades) must comply with credible International Standards such as FAA
Specification FAA-E-2470b (December 1985).
The building will have the benefit of full climate control, with the ambient
conditions in each office being individually selectable, independent of the controls
for the whole building. Measures will be taken to eradicate condensation from
within the building.
The building will have computer network including interfaces with external
systems, and it will be technology updated to support ATC & Meteorology
operations that meets ICAO standards and recommended codes and regulations.

80
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

81
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

82
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

83
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

84
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

6. AIRPORT NAVIGATION EQUIPMENT


6.1. Introduction
The basic principles of air navigation are identical to general navigation, which
includes the process of planning, recording, and controlling the movement of a
craft from one place to another.
Successful air navigation involves piloting an aircraft from place to place without
getting lost, breaking the laws applying to aircraft, or endangering the safety of
those on board or on the ground. Air navigation differs from the navigation of
surface craft in several ways: Aircraft travel at relatively high speeds, leaving
less time to calculate their position on route. Aircraft normally cannot stop in
mid-air to ascertain their position at leisure. Aircraft are safety-limited by the
amount of fuel they can carry; a surface vehicle can usually get lost, run out of
fuel, then simply await rescue. There is no in-flight rescue for most aircraft.
Additionally, collisions with obstructions are usually fatal. Therefore, constant
awareness of position is critical for aircraft pilots.
The techniques used for navigation in the air will depend on whether the aircraft
is flying under visual flight rules (VFR) or instrument flight rules (IFR). In the
latter case, the pilot will navigate exclusively using instruments and radio
navigation aids such as beacons, or as directed under radar control by air traffic
control. In the VFR case, a pilot will largely navigate using "dead reckoning"
combined with visual observations (known as pilot age), with reference to
appropriate maps. This may be supplemented using radio navigation aids.

6.2. DVOR/DME
VOR is an abbreviation for "VHF Omnidirectional Radio Range", which implies that
it operates in the VHF band. Adopted by ICAO as early as 1960, VOR has been
the main short-range navigational aid for several years. Short range infers that
ranges up to 200 NM can be expected. It is still the most commonly used short-
range aid. As opposed to the NDB, which transmits a non-directional signal, the
signal transmitted by the VOR contains directional information.The principle of
operation is bearing measurement by phase comparison. This means that the
transmitter on the ground produces and transmits a signal, or actually two
separate signals, which make it possible for the receiver to determine its position
in relation to the ground station by comparing the phases of these two signals. In
theory, the VOR produces a number of tracks all originating at the transmitter.
These tracks are called «radials» and are numbered from 1 to 360, expressed in
degrees, or ° . The 360° radial is the track leaving the VOR station towards the
Magnetic North, and if you continue with the cardinal points, radial 090° points to
the East, the 180° radial to the South and the 270° radial to the West, all in
relation to the magnetic North. See at figure below.

85
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Before we look in detail at how the system works the following example
illustrates the principle and should make it easier to understand.Think of a
lighthouse at sea and imagine the white light rotating at a speed of one
revolution per minute (60 seconds). Every time this white narrow beam passes
through Magnetic North, a green omnidirectional light flashes. Omnidirectional
means that it can be seen from any position around the lighthouse. If we are
situated somewhere in the vicinity of the light sources and are able to see them,
we can measure the time interval from the green light flash until we see the
white light. The elapsed time is directly proportional to our position line in
relation to the lighthouse.The speed of 1 RPM corresponds to 6° per second, so if
30 seconds elapse between the time we see the green flash and the white
rotating light, we are on the 180° radial, or directly south of the station (30 sec x
6°/sec = 180°). This calculation can be done from any position and the elapsed
time is directly proportional to our angular position (radial). We could name these
light signals, calling the green one the Reference (REF) signal and the white
beam the Variable (VAR) signal.

DVOR Generation
The Doppler VOR is the second generation VOR, providing improved signal
quality and accuracy. The REF signal of the DVOR is amplitude modulated, while
the VAR signal is frequency modulated. This means that the modulations are
opposite as compared to the conventional VORs. The frequency modulated signal
is less subject to interference than the amplitude modulated signal and therefore
the received signals provide a more accurate bearing determination.The Doppler
effect is created by letting the VAR signal be «electronically rotated», on the
circular placed aerials, at a speed of 30 revolutions per second. With a diameter
of the circle of 13.4 meters, the radial velocity of the VAR signal will be 1264
m/s. This will create a Doppler shift, causing the frequency to increase as the
signal is rotated towards the observer and reduce as it rotates away with 30 full
cycles of frequency variation per second. This results in an effective FM of 30 Hz.
A receiver situated at some distance in the radiation field continuously monitors
the transmitter. When certain prescribed deviations are exceeded, either the
IDENT is taken off, or the complete transmitter is taken off the air. We come

86
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

back to this in the section Limitations and accuracy.The VOR receiver does not
know if it is receiving a signal from a CVOR or a DVOR and the pilot treats both
types in the same way. The change of FM and AM for the REF and VAR signals, as
compared to the CVOR, is compensated for by having the DVOR antenna pattern
rotate the opposite way, compared to the CVOR.

Location

Oecusse Airport DVOR/DME Location

The area in which a DVOR is to be installed is determined by the responsible Civil


Aviation Authority according to the international air traffic regulations. The area
is generally sufficiently large to allow selection of a point with optimum
topography and thus the optimum propagation conditions can be met. The
installation is determined by means of a site survey at which a surveyor must
always be present. ATM can provide an engineering consultant on site for this
survey.When the installation site has been determined, precise bearings must be
taken, either with reference to trigonometrical points or, if a satellite receiver is
available, via GPS receiver for increased accuracy. Please see figure below.

Site Preparation
When the exact location of the DVOR facility is determined by the customer
and/or the Navaid Supplier, preliminary topographical and geo-technical surveys

87
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

shall be conducted.A site survey will be performed by a civil engineer.These


investigations shall provide information on existing ground conditions (soil,
water, etc.) to determine:
— Bearing capacity for the design of either high level foundations in the sand
fill or deep piled foundations
— Conductibility for the design of the earthing network,
— Existing services (pipes, cables, technical trenches, etc.).
The earth works shall allow the construction works.If necessary the earth works
shall include the demolishing of existing constructions and foundations.Each site
shall be connected to the road network of the airport. Light circulation only is
expected during the normal operation. However, the access roads shall resist to
the loads of 25 tons trucks and cranes.The energy, telephone, multi-pair cables
and the connections of the interface points to the external networks shall be
assumed by others.

Foundation Details
The overall dimensions of the DVOR counterpoise array and a general installation
overview are given in figure above. Details on the specific foundations are given
in figure above. The minimum deepness of each pier foundations must be at least
1.20 m under the ground These external dimensions are minimal, and the
effective dimensions are to be computed by the Civil Engineer according to the
nature of the soil and the local standard in force.The installation of the earthing
system shall start during the construction of foundations of antenna and shelter
slabs.

6.3. Communication Facilities (VHF)


 Air-Ground Communications
 VHF Transceiver for Operation + Backup
 VHF Transceiver for Emergency.
 Voice Recorder
 2 VCS for Main and Backup

PILOT PILOT

TOWER

PILOT PILOT

 Tower Facilities :
 Roof Floor : VHF Antennas
: Rotating Beacon

88
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

: Lightning Protection
 Cabin Floor : Desk Control &Accessories
: Signal Lamp
: Touchscreen airfield lighting panel
: Chairs
 Equipment Room : Transceiver & Transmitter Cabinet
: Recorder Cabinet

6.4. Other Communication Systems


 Ground-Ground Communications
 Direct Speech
 VHF-AM Networks Transceivers x 3
 VSAT
 AFTN

KUPANG MAKASSAR
TMA FSS

ATS
DIRECT
SPEECH

DILI TMA

 Oecusse ATS Coordination Channel :


 Oecusse Tower – Kupang Terminal (TMA)
 Oecusse Tower – Makassar Flight Service Center (FSS)
 Oecusse Tower – Dili TMA

 Oecusse Aerodrome Internal Coordination Channel :


 Tower – Briefing Office (BO)
 Tower – Operation Center (Officer in Charge / OIC)
 Tower – Security
 Tower – Rescue and Fire Fighting Services (RFFS)
 Tower – Search and Rescue (SAR) Unit
 Tower – Military
 Tower – Technical Workshop / Maintenance

6.5. ATC Equipment


 Head set
 Microphone
 Transceiver
 Speakers
 Radio Selector panel
 Telephone selector panel/headsets
 Intercom
 Auto-switch headset/speaker
 Recorder (radio & telephone)
 Signal lamp and reel
 Binoculars
 Rotating Beacon

89
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 Wind speed and direction display


 Barometric altimeter
 Altimeter setting indicator
 Digital Clock
 Touchscreen airfield lighting panel
 lighting panel
 Navaids monitor panel
 Lighting, including emergency light
 Daylight radar /display consoles
 Flight data panel
 Clipboards / display (NOTAM etc.)
 Fire alarm and extinguishers
 Desks /consoles/shelves
 Chairs
 Shades
 Air conditioning
 Water fountain/purifier
 Bookcases
 Sound-absorbing coverings (wall/floor).

6.6. Navigation Aids


Indicator and signaling devices
a. Wind Direction indicator ( WDI)
Description, an aerodrome shall be equipped with at least one wind direction
indicator. A wind direction indicator shall be located so as to be visible from
aircraft in flight or on the movement area and in such a way as to be free
from the effects of air disturbances caused by nearby objects. Design and
construction, The wind direction indicator should be in the form of a
truncated cone made of fabric and should have a length of not less than 3.6
m and a diameter, at the larger end, of not less than 0.9 m. It should be
constructed so that it gives a Clean indication of the direction of the surface
wind and a general indication of the wind speed. The color or colors should
be so selected as to make the wind direction indicator Cleanly visible and
understandable from a height of at least 300 m, having regard to
background. Where practicable, a single color, preferably white or orange,
should be used. Where a combination of two colors is required to give
adequate conspicuity against changing backgrounds, they should preferably
be orange and white, red and white, or black and white, and should be
arranged in five alternate bands, the first and last bands being the darker
color. Location, The location of at least one wind direction indicator should be
marked by a circular band 15 m in diameter and 1.2 m wide. The band
should be centered about the wind direction indicator support and should be
in a color chosen to give adequate conspicuity, preferably white. A wind
direction indicator provided at the threshold of a runway must be located:
(a) Except if it is not practicable to do so, on the left hand side of the runway
as seen from a landing aircraft; and
(b) Outside the runway strip; and
(c) Clean of the transitional obstacle limitation surface.

90
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

b. Siren (SIR)
Description, Siren serves as the user information to the runway. When the
siren sounded, then all the activities that may be present on the runway
immediately step aside, because there will be a plane that is landing or
flying.
Design, construction, Electrical motorized siren consists of a siren with a
capacity of 3-5 horsepower and 134 db. Operated by technician in Main
Power House (MPH), and Air Traffic Controller in Tower.
Location, beyond the runway strip and strip at a distance of approximately
midway between threshold RW 08 and 26.

c. Aerodrome Rotating Beacon


Description, The main purpose of rotating beacon is to indicate the location of
a lighted airport, and a rotating beacon is an integral part of an airfield
lighting system.
Aerodrome rotating beacon project a beam of light in two directions, 180°
apart. The optical system consists of one green lens and one Clean lens. The
rotating mechanism is designed to rotate the beacon to produce alternate
white and green flashes of light with a flash rate 20-30 flash per minute.
Airport rotating beacon is mounted higher than any surrounding obstruction,
beacon may be mounted on the roof of hangars, or other buildings; normally
on top of control Towers to avoid blinding the controllers.

Lights
a. Description, A non-aeronautical ground light near an aerodrome which might
endanger the safety of aircraft shall be extinguished, screened or otherwise
modified so as to eliminate the source of danger. To protect the safety of
aircraft against the hazardous effects of laser emitters, the following
protected zones should be established around aerodromes:
— A laser-beam free flight zone (LFFZ)

91
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

— A laser-beam critical flight zone (LCFZ)


— A laser-beam sensitive flight zone (LSFZ).
Figures below may be used to determine the exposure levels and distances
that adequately protect flight operations. The restrictions on the use of laser
beams in the three protected flight zones, LFFZ, LCFZ and LSFZ, refer to
visible laser beams only. Laser emitters operated by the authorities in a
manner compatible with flight safety are excluded. In all navigable airspace,
the irradiance level of any laser beam, visible or invisible, is expected to be
less than or equal to the maximum permissible exposure (MPE) unless such
emission has been notified to the authority and permission obtained. The
protected flight zones are established in order to mitigate the risk of
operating laser emitters in the vicinity of aerodromes. Further guidance on
how to protect flight operations from the hazardous effects of laser emitters
is contained in the Manual on Laser Emitters and Flight Safety (Doc 9815).
See also ICAO Annex 11 — Air Traffic Services, Chapter 2.

92
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

b. Lights which may cause confusion


A non-aeronautical ground light which, by reason of its intensity,
configuration or color, might prevent, or cause confusion in, the Clean
interpretation of aeronautical ground lights should be extinguished, screened
or otherwise modified so as to eliminate such a possibility. In particular,
attention should be directed to a non-aeronautical ground light visible from
the air within the areas described hereunder:
a) Instrument runway — code number 4:
Within the areas before the threshold and beyond the end of the runway
extending at least 4 500 m in length from the threshold and runway end
and 750 m either side of the extended runway centre line in width.
b) Instrument runway — code number 2 or 3:
As in a), except that the length should be at least 3.000 m.
c) Instrument runway — code number 1;
And non-instrument runway: Within the approach area.

c. Aeronautical ground lights which may cause confusion to mariners


In the case of aeronautical ground lights near navigable waters, consideration
needs to be given to ensuring that the lights do not cause confusion to
mariners.

d. Light fixtures and supporting structures


See ICAO Aerodrome Design Manual (Doc 9157), Part 6, for guidance on
frangibility of light fixtures and supporting structures.

e. Light intensity and control


In dusk or poor visibility conditions by day, lighting can be more effective
than marking. For lights to be effective in such conditions or in poor visibility
by night, they must be of adequate intensity. To obtain the required
intensity, it will usually be necessary to make the light directional, in which

93
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

case the arcs over which the light shows will have to be adequate and so
orientated as to meet the operational requirements. The runway lighting
system will have to be considered as a whole, to ensure that the relative light
intensities are suitably matched to the same end. (See ICAO Aerodrome
Design Manual (Doc 9157), Part 4).
The intensity of runway lighting shall be adequate for the minimum
conditions of visibility and ambient light in which use of the runway is
intended, and compatible with that of the nearest section of the approach
lighting system when provided.
While the lights of an approach lighting system may be of higher intensity
than the runway lighting, it is good practice to avoid abrupt changes in
intensity as these could give a pilot a false impression that the visibility is
changing during approach.
Where a high-intensity lighting system is provided, a suitable 5 step intensity
control shall be incorporated to allow for adjustment of the light intensity to
meet the prevailing conditions. Separate intensity controls or other suitable
methods shall be provided to ensure that the following systems, when
installed, can be operated at compatible intensities:
 approach lighting system;
 Runway edge lights;
 Runway threshold lights;
 Runway end lights;
 Taxiway edge lights.
 RTIL
 Runway Turn Pad Lights

f. Elevated approach lights


Elevated approach lights and their supporting structures shall be frangible on
impact but resist to jet blast except in that portion of the approach lighting
system beyond 300 m from the threshold:
1) where the height of a supporting structure exceeds 12 m, the frangibility
requirement shall apply to the top 12 m only
2) Where a supporting structure is surrounded by non-frangible objects,
only that part of the structure that extends above the surrounding
objects shall be frangible on impact but resist to jet blast.
When an approach light fixture or supporting structure is not in itself
sufficiently conspicuous, it shall be suitably marked.

g. Elevated lights
Elevated runway, stop way and taxiway lights shall be frangible. Their height
shall be sufficiently low to preserve Cleanance for propellers and for the
engine pods of jet aircraft.

94
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

h. Surface lights
Light fixtures inset in the surface of runways, stop ways, taxiways and
aprons shall be so designed and fitted as to withstand being run over by the
wheels of an aircraft without damage either to the aircraft or to the lights
themselves.
The temperature produced by conduction or radiation at the interface
between an installed inset light and an aircraft tire should not exceed 160°C
during a 10-minute period of exposure.
Guidance on measuring the temperature of inset lights is given in the ICAO
Aerodrome Design Manual (Doc 9157), Part 4.

1. Simple Approach Lighting System ( SALS)


Description,
The function of approach lighting is to provide a visual clue to the pilot
that he was located in the area approach to land his plane.
Design, construction. The light of a simple approach lighting system shall
consist of a row of lights on the extended centre line of the runway
extending.
The light of a simple approach lighting system shall be fixed lights and
the color of the lights shall be such as to ensure that the system is
readily distinguishable from other aeronautical ground lights, and from
extraneous lighting if present.
The centre line shall be placed at longitudinal intervals of 60 m, except
that, when it is desired to improve the guidance, an interval of 30 m may
be used. The innermost light shall be located either 60 m or 30 m from
the threshold,

Location,
Installation SALS for Oecusse Instrument Non-Precision Runway, 300 m
SALS is more preferable. A simple approach lighting system shall consist
of a row of lights on the extended centre line of the runway extending,
whenever possible, over a distance of not less than 420 m from the
threshold with a row of lights forming a crossbar 18 m or 30 m in length
at a distance of 300 m from the threshold. According to ICAO Annex 14,
Para. 5.3.4.5: Recommendation. —If it is not physically possible to
provide a centre line extending for a distance of 420 m from the
threshold, it should be extended to 300 m so as to include the crossbar.
If this is not possible, the centre line lights should be extended as far as
practicable, and each centre line light should then consist of a barrette at
least 3 m in length. Subject to the approach system having a crossbar at
300 m from the threshold, an additional crossbar may be provided at150
m from the threshold. The lights forming the crossbar shall be as nearly
as practicable in a horizontal straight line at right angles to, and bisected

95
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

by, the line of the centre line lights. The lights of the crossbar shall be
spaced so as to produce a linear effect, except that, when a crossbar of
30 m is used, gaps may be left on each side of the centre line. These
gaps shall be kept to a minimum to meet local requirements and each
shall not exceed 6 m. Spacing for the crossbar lights between 1 m and 4
m are in use. Gaps on each side of the centre line may improve
directional guidance when approaches are made with a lateral error, and
facilitate the movement of rescue and fire fighting vehicles. The lights
forming depending on the longitudinal interval selected for the centre line
lights.

2. Visual approach slope indicator systems


Application,
A visual approach slope indicator system shall be provided to serve the
approach to a runway whether or not the runway is served by other
visual approach aids or by non-visual aids, where one or more of the
following conditions exist:
a) The runway is used by turbojet or other aircrafts with similar
approach guidance requirements;
b) The pilot of any type of aircraft may have difficulty in judging the
approach due to:
1) Inadequate visual guidance such as is experienced during
an approach over water or featureless terrain by day or in
the absence of sufficient extraneous lights in the
approach area by night.
2) Misleading information such as is produced by deceptive
surrounding terrain or runway slopes.

96
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

c) The presence of objects in the approach area may involve serious


hazard if an aircraft descends below the normal approach path,
particularly if there are no non-visual or other visual aids to give
warning of such objects
d) Physical conditions at either end of the runway present a serious
hazard in the event of an aircraft undershooting or overrunning
the runway
e) Terrain or prevalent meteorological conditions are such that the
aircraft may be subjected to unusual turbulence during approach.

The standard visual approach slope indicator systems shall consist of the
following:
a) T-VASIS and AT-VASIS conforming to the specifications contained
in 3.5.6 to 3.5.22 of Aerodromes, Annex 14, Volume I Aerodrome
Design and Operations, sixth edition, July 2013, International
Civil Aviation Organization (ICAO).
b) PAPI and APAPI systems conforming to the specifications
contained in 3.5.23 to 3.5.40 inclusive as shown in Figure 5-16.

PAPI, T-VASIS or AT-VASIS shall be provided where the code number is 3


or 4 when one or more of the conditions specified in 3.5.1 of
Aerodromes, Annex 14, Volume I Aerodrome Design and Operations,
sixth edition, July 2013, International Civil Aviation Organization (ICAO).
PAPI or APAPI shall be provided where the code number is 1 or 2 when
one or more of the conditions specified in 3.5.1 of Aerodromes, Annex
14, Volume I Aerodrome Design and Operations, sixth edition, July 2013,
International Civil Aviation Organization (ICAO).

3. Precision Approach Path Indication ( PAPI)


Description, the PAPI system shall consist of a wing bar of 4 sharp
transition multi lamp (or paired single lamp) units equally spaced. The
system shall be located on the left side of the runway unless it is
physically impracticable to do so. The wing bar of PAPI shall be
constructed and arranged in such a manner that a pilot making an
approach will:
- When on or close to the approach, see the two units nearest the
runway as red two units, further form the runway as white.
- When above the approach slope, see the one unit nearest the
runway as red and the three furthers from the runway white. And
when further above the approach slope, see all units as white.
- When below the approach slope, see the three units nearest the
runway as red and the units further the runway as whit, and
when further below the approach slope see all red.

97
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Sitting, the light units shall be located as in the basic configuration


illustrated in Figure 5-19, subject to the installation tolerances given
therein. The units forming a wing bar shall be mounted so as to appear to
the pilot of an approaching aircraft to be substantially in a horizontal line.
The light units shall be mounted as low as possible and shall be frangible.

98
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Correction distance, D1 will be correction if level of runway and threshold


difference level, the formula to calculated D1 as below:

99
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

4. Obstacle protection surface


The following specifications apply to T-VASIS, AT-VASIS, PAPI and APAPI.
An obstacle protection surface shall be established when it is intended to
provide a visual approach slope indicator system. The characteristics of
the obstacle protection surface, i.e. origin, divergence, length and slope,
shall correspond to those specified in the relevant column of Table 5-3
and in Figure 5-21 of Aerodromes, Annex 14, Volume I Aerodrome
Design and Operations, sixth edition, July 2013, International Civil
Aviation Organization (ICAO)..

100
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

New objects or extensions of existing objects shall not be permitted above an


obstacle protection surface except when, in the opinion of the appropriate
authority, the new object or extension would be shielded by an existing
immovable object. Circumstances in which the shielding principle may
reasonably be applied are described in the ICAO Airport Services Manual (Doc
9137), Part 6.Existing objects above an obstacle protection surface shall be
removed except when, in the opinion of the appropriate authority, the object
is shielded by an existing immovable object, or after aeronautical study it is
determined that the object would not adversely affect the safety of
operations of aircrafts. Where an aeronautical study indicates that an existing
object extending above an obstacle protection surface could adversely affect
the safety of operations of aircrafts one or more of the following measures
shall be taken:
a) Suitably raise the approach slope of the system;
b) Reduce the azimuth spread of the system so that the object is outside the
confines of the beam;
c) Displace the axis of the system and its associated obstacle protection
surface by no more than 5°
d) Suitably displace the threshold; and
e) Where d) is found to be impracticable, suitably displace the system upwind
of the threshold to provide an increase in threshold crossing height equal
to the height of the object penetration.

Guidance on this issue is contained in the Aerodrome Design Manual (Doc


9157), Part 4.

6.7. Meteorological Service (MET-Service)

The ATC Tower also has Meteorology Services so it is fully capable for traffic
control services and to update weather condition and reported it to the airman. It
shall prepare and obtain forecasts and other relevant information for flights and
for local meteorological forecasting. It maintains a continuous survey of the
meteorological conditions at the airport as well as provides briefing, consultation
and flight documents to flight crew members and other flight operation
personnel. The information will be provided through an automated self-briefing
service like AWOS (Automated Weather Observing System) .The AWOS equipment
are used for provide aerodrome weather to improve Pilot safely and efficient
take-off and landing at the airport. The services of the AWOS is operated
directly send weather data of aerodrome from sensor to ATC at cabin Tower and

101
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Meteorology Office on the ground. The AWOS Oecusse International Airport to


be used for Pilot take-off and landing at the airport concerned. Equipment
specification of the AWOS are equipped with Wind speed and direction sensor,
weather sensor, temperature and due point sensor, visibility sensor, cloud base
sensor, and altimeter sensor.

6.8. Airfield Lighting Systems


Runway Lighting,
Characteristics
Runway edge lights shall be fixed lights showing variable white, except that:
o in the case of a displaced threshold, the lights between the beginning of the
runway and the displaced threshold shall show red in the approach direction;
and
o A section of the lights 600 m or one-third of the runway length, whichever is
the less, at the remote end of the runway from the end at which the take-off
run is started, may show yellow.

The runway edge lights shall show at all angles in azimuth necessary to provide
guidance to a pilot landing or taking off in either direction. When the runway
edge lights are intended to provide circling guidance, they shall show at all
angles in azimuth (see 5.3.6.1 of ICAO Annex 14, sixth edition, 2013). In all
angles of azimuth required in 5.3.9.8 of ICAO Annex 14, sixth edition, 2013,
runway edge lights shall show at angles up to 15° above the horizontal with
intensity adequate for the conditions of visibility and ambient light in which use
of the runway for take-off or landing is intended. In any case, the intensity shall
be at least 50 cd except that at an aerodrome without extraneous lighting, the
intensity of the lights may be reduced to not less than 25 cd to avoid dazzling the
pilot. Runway edge lights on a precision approach runway shall be in accordance
with the specifications of Appendix 2, Figure A2-9 or A2-10 of ICAO Annex 14,
sixth edition, 2013.
The runway edge lights emit white light except in the caution zone (not
applicable to visual runways) which is the last 600 m of runway or one-third the
runway length, whichever is less. In the caution zone, white lights are substituted
for yellow lights; they emit yellow light in the direction facing the instrument
approach threshold and white light in the opposite direction. Instrument
approach runways are runway end specific, meaning a runway may have an
instrument approach on one end and a non-instrument approach on the opposite
end. However, when there is an instrument approach at each runway end,
yellow/white lights are installed at each runway end in the directions described
above.

Location
The runway edge lights are located on a line parallel to the runway centerline at

102
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

least 2 ft. (0.6 m), but not more than 10 ft. (3 m), from the edge of the full
strength pavement designated for runway use. On runways used by jet aircraft,
we recommend 10 ft. (3 m) to avoid possible damage by jet blast. On runways
not used by jet aircraft, we recommend 2 ft. (0.6 m). The edge lights are
uniformly spaced and symmetrical about the runway centerline, such that a line
between light units on opposite sides of the runway is perpendicular to the
runway centerline. Longitudinal spacing between light units must not exceed
60m, except as described in paragraph 5.3.9.6 of ICAO Annex 14, sixth edition,
2013. Use the threshold/runway end lights as the starting reference points for
longitudinal spacing calculations during design.

Threshold and End Lighting,


General, description, Runway Thresholds. Threshold lights emit green light
outward from the runway and emit red light toward the runway to mark the ends
of the runway. The green lights indicate the landing threshold to arriving aircraft
and the red lights indicate the end of the runway for departing aircraft. The red
and green lights are usually combined into one fixture and special lenses or filters
are used to emit the desired light in the appropriate direction. It is possible with
difference armature (red and green).
Configuration, Threshold lighting shall consist of on non-precision approach
runway at least six lights.
Location, The combination threshold and runway end lights are located on a line
perpendicular to the extended runway centerline not less than 2 ft. (0.6 m) and
not more than 10 ft. (3 m) outboard from the designated runway threshold.

Runway Threshold Identification Lights


Runway threshold identification lights should be installed:
a. At the threshold of a non-precision approach runway when additional
threshold conspicuity is necessary or where it is not practicable to provide
other approach lighting aids; and
b. Where a runway threshold is permanently displaced from the runway
extremity or temporarily displaced from the normal position and additional
threshold conspicuity is necessary.
Runway threshold identification lights shall be located symmetrically about the
runway centre line, in line with the threshold and approximately 10 m outside
each line of runway edge lights. Runway threshold identification lights should be
flashing white lights with a flash frequency between 60 and 120 per minute. The
lights shall be visible only in the direction of approach to the runway.

Taxiway edge light


General description, Taxiway edge lighting systems are configurations of lights
that define the lateral limits of the taxiway. The taxiway edge lights emit blue
light, and edge reflectors reflect blue.

103
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Location, Fixtures in the edge lighting system are located in a line parallel to the
taxiway centerline not more than 10 ft. (3 m) outward from the edge of the full
strength pavement.
The spacing for taxiway edge lights is calculated based on the taxiway
configuration.

104
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Runway Turn Pad Lights (For additional Works)


Runway turn pad lights shall be provided for continuous guidance on a runway
turn pad intended for use in runway visual range conditions less than a value of
350 m, to enable an aeroplane to complete a 180-degree turn and align with the
runway centre line. Runway turn pad lights should be provided on a runway turn
pad intended for use at night. Runway turn pad lights should normally be located
on the runway turn pad marking, except that they may be offset by not more
than 30 cm where it is not practicable to locate them on the marking. Runway
turn pad lights on a straight section of the runway turn pad marking should be
spaced at longitudinal intervals of not more than 15 m. Runway turn pad lights
on a curved section of the runway turn pad marking should not exceed a spacing
of 7.5 m.

Control system
General Description of Airfield Lighting Control. The control system for airfield
lighting consists of control panels, relaying equipment, accessories, and circuits
which energize, de-energize, select lamp brightness, and otherwise control
various airfield lighting circuits based on operational requirements. Control of any
one airfield lighting system is normally provided at two points only: the ATCT,
and the vault which powers the system.
a. Some airfield control/monitoring systems have been installed using
Programmable Logic Controllers (PLCs), which have good industrial standards
and proven reliability. The PLC industrial systems use high I/O modules that
reduce the need for multi-pair cable installation. Cables with 2 to 6 pairs are
typically needed, although fiber optic cable can also be used.
b. PC-based systems have come into use, with computers located in the ATCT,
the vault, and/or other work stations. These systems have the capability of
displaying the necessary information on a monitor. This is the most flexible

105
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

system in use today, with off-the-shelf units readily available. Typically,


standard operating software is used, and off-the-shelf graphics software is
tailored for a specific site. The communications cable requirements are 2 to 6
pairs of cable or fiber optics. Non armored Fiber optic cable eliminates the
need for separate ducts since there will be no interference between power
cable and fiber optic cable.

6.9. Signs
a. Mandatory Signs
General, description, mandatory instruction sign identification a location on
the movement area that a pilot or vehicle driver should no pass without
specified authorization by ATC. Mandatory instruction signs are therefore an
import and element of the safety provisions on movement area. Location, a
mandatory instruction sign shall always be provided at a taxiway/runway
intersection or a runway/runway intersection on each side of the runway
holding position.

106
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

b. Information Signs
General, description, An information sign shall be provided where there is an
operational need to identify by a sign, specific location, or routing ( direction,
or destination) information. Information shall include: direction signs,
location signs, destination signs, runway exit signs, runway vacated signs,
and intersection take off signs.
Location, a location sign shall be provided in conjunction with a runway
designation sign except at a runway /runway intersection. A location sign

107
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

shall be provided in conjunction with a direction sign, except that it may be


omitted where an aeronautical study indicates that it is not needed.

6.10. Lightning Protection


Counterpoise (Lightning Protection System).
General, Description, The purpose of the counterpoise system (lightning
protection system) is to provide a low resistance preferred path for the energy
from lightning discharges to enter the earth and safely dissipate without causing
damage to equipment or injury to personnel. The counterpoise system is installed
on airfields to provide some degree of protection against the energy induced
from lightning strikes to underground power and control cables. The counterpoise
is a separate system and must not be confused with the light base grounding (for
series constant current circuits) and equipment grounding (for parallel voltage
circuits). Both grounding methods are intended to provide a low impedance
current path to earth for an unintentional conductive connection between an
ungrounded conductor (power) and normally non-current carrying conductors
(example: a short from the power conductors to the light base).

108
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

7. PASSENGER TERMINAL
7.1. Introduction

The Passenger Terminal Area is perhaps the highest profile part of the Airport
development, as it is the area that the travelling public will remember the
most. Air travel is now the principal means of international travel and, as a
major district city airport, Oecusse-Ambeno will represent a major gateway
to Pante Makassar and East Timor, both for visitors and to the world. As
such, the terminal area bears a heavy responsibility to express the
aspirations of a nation that has a proud tradition and to embody a unique
sense of place that locates this complex threshold between the land and the
air firmly in the surroundings of Timor and in the twenty-first century.

Figure – Passenger Terminal Building, Land Side 3D view

The passenger terminal and its interfaces are intimately connected to the
City. The key guiding principles for the development of the design which
have been applied along this initial Master Planning stage are as follows:
 To seek innovative and creative solutions;
 To provide as many stands in a compact area as can be achieved,
balanced with the landside facilities, in one terminal complex;
 To create a building which is capable of incremental phased
expansion with minimal operational disruption;
 To provide an efficient facility designed for hub operations and short
connection times;
 To provide a high level of passenger service and quality;
 To be cost effective;
 To emphasise public transport access location and visibility;
 To create a strong connection between the Terminal and the City;
 To ensure that the view of the terminal is not obscured by car parks;
 To create a passenger journey that is visible and linear;
 To optimise the use of natural light;
 To develop a sustainable solution approaching carbon neutrality.

109
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

In order to meet these basic criteria and principles, a rectangular-shape


terminal has been developed. This shape has a number of key
advantages:

 Expansion Development
 Modular construction method
 Allocates several Airport General Services
 Central Retail and Concession dedicated areas.

7.2. Planning Process


This section describes the process that was developed in order to establish
the preferred terminal layout that is now integrated into the Masterplan
Design Notes:

An option process was undertaken by the Technical Consultant, WIKA and PT


INDULEXCO for the Terminal and terminal area, including its surface access
and the City area located to the south, to review ways of optimising the
scheme in terms of function, operation and land take. Three principal high-
level drivers affected the terminal area and landside optioneering process as
follows:

 Airside Operational review


 Terminal overall footprint and geometry
 Road alignment and terminal processor location

Process

The first phase involved both an internal workshop and an external


workshop, between Technical Consultant and Design Team, where several
concept alternatives were evaluated against and evaluation criteria were
established. There were also following extensive discussions regarding the
advantages and disadvantages associated with each concept and the
completion of the evaluation process. These concepts were further
developed in the second phase, and then subjected to a more micro level
evaluation process whereby the stand layout, phasing, potential floor area
and travel distance where thoroughly analysed. Based on this analysis, the
preferred terminal concept was selected.

The ongoing development and optimisation of the terminal scheme has


resulted in a stretched rectangular-shape, with all the main processor
activities in separated positions along the building. This allows expansion of
the building for the tops, providing expansion by incremental phases. The
stretched rectangular-shape provides a number of benefits, as follows:

 The Aircraft stand layouts in a perpendicular position;


 A more space-efficient central core to the building;
 Simpler and more intuitive wayfinding;
 Simpler and more intuitive passenger flows;
 Simpler expansion strategy.

110
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

7.3. Design Approach


Introduction

This project is one of the largest developments to take place in East Timor in
recent years. It encompasses a wide variety of buildings of differing size and
function that may ultimately be procured via different methods and by
different bodies.

Given the sheer size of the development and diversity of its component
buildings, it is essential to the visual continuity and cohesion of the project
that a design approach guide is developed during the next design stages.
Without dictating design solutions, it will be possible for this guide to
establish a framework of design goals.

The Terminal

Airport terminals – either by their very size as well as their civic significance
- now represent some of the most significant building commissions, and
much architectural energy is expended in developing and refining their form
and expression.

There are many approaches to the challenge of designing an Airport


Terminal. But for this design team the best expression is nature…

“Architecture should speak of its time and place, but yearn for
timelessness” - Architect Frank Gehry

In Oecusse-Ambeno, there is the climate, the quality of the light and the
presence and importance of the sea with its embodiment of exploration and
travel. Oecusse-Ambeno is rich in natural architectural themes, and there
are significant inspirations from which the design can draw from.

Design Issues

Some of the issues that have been considered in the initial design concepts
for the terminal building are outlined below:

Scale

There are two key issues in managing the outsize scale of a Terminal
building. The first is to ensure that the building relates to the people that it is
serving, and the second is to manage the transition from a roadside scale of
people and cars to an airside scale of aircrafts. The relationship of roof to
kerbside is key in terms of weather protection and scale of the landside
building. The roof height continues to be the main dictator of scale within the
building and will undulate according to the function and importance of the
space which it encloses.

Natural Light

The quality of light in Oecusse-Ambeno is exceptional, and is a result of the


benign climate and the maritime location on the north Shore of Timor Island.

The building has been designed to bring in as much natural light as possible,
as this gives a calming influence and assists in orientation and way-finding.
Daylight is also carbon neutral, providing it does not lead to solar gain.

111
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Image – Typical sunset brightness

Open Hall

The design of the open Hall canyon space will allow to accommodate several
operational areas, using a well ventilates space with a strong indirect natural
lightning provided by the perforated façade protection.

On the lower level, the connection between the public space and operational
areas is completely direct and the relationship between the outside and inside is
very ambiguous, providing a user-friendly character. Several services like
Customs, Immigration, and Concessions will be incorporated in this area. This
space also accommodates the Check-In, VIP, dedicated Arrivals Hall and the
principal vertical circulation, where all these all functions will benefit greatly from
natural lighting.

The vertical circulation leads up to Departures Hall, where one can go to


International and Domestic dedicated areas, as well as access the airport main
services and police station.

Also for future flexibility the Open Hall provides sufficient space to easily
accommodate additional circulation routes.

112
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure – Passenger Terminal Building Concourse Hall - 3D view

The Roof

The shape of the roof reflects an inspired movement of the setting, and defines
its hierarchy as a building. It gently curves up to provide more space in busy
primary areas, for example the check-in hall and the retail areas, where
passengers are likely to spend a greater proportion of their time. The height and
shape of the roof will be used to guide passengers to these prime spaces - from
check-in to retail areas.

Figure – Concept Roof Design

Passenger Experience

Entering or leaving a country is Cleanly an important moment to all who


experience it, and the airport is the threshold at which this event occurs - it is
important that it is a place that one experiences and not just a process in a
building. Airports particularly express how a culture and society represents itself

113
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

to the world. The route up to and through the building should be given careful
consideration to ensure that both the departing and arriving passenger
experience is memorable and uplifting.

Both departing and arriving passengers experience a variety of spaces during


their transit from check in to the boarding gate, hence the glazed air side façade
for the arrivals and departures that allows the apron view.

Sustainability

Much of the design effort regarding the geometry of the Terminal was centered
on how to create the most efficient footprint for the terminal area, minimizing
long passenger journeys within the building, as well aircraft travel distances
around the airfield.

The north- south orientation of the building must be carefully considered, as and
the enclosure developed, concerning solar gain and glare issues relating to the
long east and west facing facades.

Perhaps one of the most significant features of the building is the roof, which
covers approximately 0,7ha. This offers a magnificent opportunity to capture the
sun‘s energy through solar collection (solar panels or photovoltaic cells) and to
capture its light and redirect it deep into the building (via optical cable systems).
In addition, the roof provides an excellent opportunity to collect and recycle rain
water.

Terminal Approach

This is the first and last impression that the passenger will have of the airport
and is, therefore, of great significance. The Terminal interfaces with the Pante
Makassar city and the design seeks to optimize the experience of this public
space which is also the transport interchange. An important public plaza is
located directly at the front of the building, which represents the connection
between East Timor's rich cultures with the world.

Landscape

The new airport is located in a largely rural area. Whilst considerable work is
required to create a suitable platform for the airfield, the beauty of the
surroundings will still be apparent. The landscape can be brought right into the
heart of the Terminal area and be a key element in the urban design of the public
car parks so that it can genuinely be appreciated by passengers and those
working at the airport.

114
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

7.4. Base Data and Assumptions


The terminal sizing is based on the busy hour rate for the year of the relevant
planning horizon. Area calculations are based on a minimum of IATA passenger
level of service C. The terminal is to be sized at opening day (2018) for 2020
capacity. This is known as phase 1. Further incremental expansion will occur up
to future around 2050 and if sooner if demands ably to it. The following indicates
the passenger figures, given from the Owner scope assumptions for traffic
forecast, that have been used to determine the terminal sizing for 2018 and
2050:

Annual Forecasts:

Arrivals 2018 2050

TOTAL 125,000 500,00

Departures 2018 2050

TOTAL 125,000 500,000

Design Day Forecast:

TOTAL 2018 2050

TOTAL 800 1600

ARRIVALS 2018 2050

TOTAL 400 800

DEPARTURES 2018 2050

TOTAL 400 800

Peak Hour Forecast:

TWO-WAY 2018 2050

Domestic 250 500

International 380 760

Total 630 1,260

115
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

ARRIVALS 2018 2050

Domestic 250 500

International 380 760

Total 630 1,260

DEPARTURES 2018 2050

Domestic 250 500

International 380 760

Total 630 1,260

Table - Traffic Forecast

As the scheme has developed, a number of assumptions have been made and
developed throughout the planning process. These are as follows:

Terminal

 Efficiency of central core to be optimized, in order to reduce excess floor


area;

 Locate swing gates and corridors to optimize terminal operations;

 Flexibility in terms of airline assignment strategy;

 Maximize use of natural light, while controlling solar gain;

 Optimize retail footfall, penetration and visibility;

 Check-in to be a flow through system to optimize flows and assist way-


finding;

 Once security checked, passengers will flow into large retail areas;

 Domestic arriving and departing passengers will mix;

Landside Access

 Terminal related access to be separated from Airport Services Areas;

 Separate Arrival and departure curbs;

 Separate VIPS curb side

 Curbs to accommodate cars, taxis and buses;

 Dedicate service access;

 Car Rental to be located on the car park;

116
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

7.5. Land Plot Requirements - Terminal Area

Terminal Areas

In order to provide a comparative calculation, the following is a schedule of areas


from the terminal plans in 2018 and 2050:

2018 (m²) 2050 (m²)

Arrivals/BHS Level 00.00 4,570 6.030

Departures/Arrivals/HBS Level +5.00 3,674 5,080

Service Area Level +10.00 414 600

TOTAL 8,658 11,710

Table - Land Plot Area

The total area in 2018 indicated is 8 659m², and in 2050 is 11 710m².


1.5.3 These figures represented a scheme that incorporates Owners‘
aspirations, stakeholder requirements and principal space requirements for the
terminal systems and processes. It should be noted, however, that further
development is required to integrate the scheme and these areas should be read
as indicative at this stage and reflecting the scheme in its current stage of
development.

7.6. Facility Summary


Terminal Sizing

The Terminal building was initially sized using a Planning Model which is a
theoretical calculation that gives an order of magnitude for the Terminal size and
an estimate of processor numbers required, but after a closer local analysis, the
numbers provided actually oversize‘s it. As described above, this theoretical area
is generally bigger than the actual Terminal size, which is dictated by a number of
factors including geometry, circulation, gate layouts, etc.

The number of processors required has then been further refined through scope
assumption, in order to minimize queue times and dedicated area.

The following table indicates the target number of processors which have been
established through the simulation study:

2018 2050

Check-in at Terminal

Conventional 12 18

Out Format 1 2

Electronic Kiosks 5 10

117
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Boarding Pass 2 4

Security Portico and Holding Bag x-ray 4 6

Emigration Positions* 4 6

Transfer facilities - Total

Security 0 1

Immigration 0 2

Immigration 4 6

Baggage Claim Unit - 40 meters 3 5

Customs 2 4

Bag Screening Equipment 2 3

Baggage Make-up Positions 2 3

Table – Processors Requirements

The following table illustrates the building areas:

Passengers Terminal Building

Number Name Department Area

LEVEL O

0.86 Domestic Baggage Reclaim Hall Airside Domestic Public 320.61


0.88 Toilets Men Airside Domestic Public 9.92
0.89 Toilets Women Airside Domestic Public 7.89
0.90 Toilets Disabled/Nursery Airside Domestic Public 4.92
SUBTOTAL 343.34

0.55 International Arrival Hall Airside International Public 45.54


0.65 Toilets Disabled/Nursery Airside International Public 5.63
0.66 Toilets Women Airside International Public 20.45
0.67 Toilets Men Airside International Public 19.34
0.71 International Baggage Reclaim Hall Airside International Public 502.49
SUBTOTAL 593.45

0.78 International Custom Check Customs Service Airside 133.71


0.79 Hall Holding Area Customs Service Airside 25.67
0.80 Confiscated Goods Deposit Customs Service Airside 9.43
0.81 Supervisor's Office Customs Service Airside 13.6
0.82 Detention Room Customs Service Airside 5.4

118
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

0.83 Search Room Customs Service Airside 7.85


0.84 Search Room Customs Service Airside 7.68
SUBTOTAL 203.34

0.40 Customs VIP Customs Service Landside 4.45


0.76 Support Office Customs Service Landside 6.45
0.77 Customs Hall Customs Service Landside 7.64
SUBTOTAL 18.54

0.51 Immigration Immigration Services Airside 154.69


0.52 Holding Area Hall Immigration Services Airside 21.51
0.53 Detention Room Immigration Services Airside 8.22
0.54 Immigration Supervisor Immigration Services Airside 9.73
SUBTOTAL 194.15

0.06 Check In queue Landside Public 605.42


0.20 Toilets Men Landside Public 16.4
0.21 Toilets Women Landside Public 32.41
0.22 Toilets Disabled/Nursery Landside Public 3.18
0.24 Landside Councourse Hall Landside Public 1101.59
0.25 Hall / Security Check Landside Public 46.2
0.73 Toilets Men Landside Public 14.2
0.74 Toilets Disable / Nursery Landside Public 3.59
0.75 Toilets Women Landside Public 15.05
SUBTOTAL 1838.04

0.56 Triage Quarentine Services 17.96


0.57 Depot Quarentine Services 13.34
0.58 Isolation Room Quarentine Services 15.56
0.59 Doctor's Office Quarentine Services 15.64
SUBTOTAL 62.5

0.01 Retail/Concession Retail/Concession/F&B 26.1


0.02 Retail/Concession Retail/Concession/F&B 25.2
0.03 Retail/Concession Retail/Concession/F&B 12.29
0.04 Retail/Concession Retail/Concession/F&B 25.2
0.05 Retail/Concession Retail/Concession/F&B 25.2
0.09 Concessions Retail/Concession/F&B 65.39
0.69 International Arrivals Duty Free Retail/Concession/F&B 22.73
SUBTOTAL 202.11

0.43 Immigration Immigration Services Landside 5.72

119
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

0.60 Support Office Immigration Services Landside 8.46


0.61 Immigration Hall Immigration Services Landside 9.91
SUBTOTAL 24.09

0.08 Outbound Baggage Service Airside 137.56


0.16 Baggage Support Service Airside 18.04
0.17 Fire Safety Depot Service Airside 7.31
0.18 Toilets Men Service Airside 10.7
0.19 Toilets Women Service Airside 7.22
0.33 Circulation Service Airside 13.78
0.48 Janitor Service Airside 6.57
0.63 Break Room Service Airside 8.04
0.64 Toilets Service Airside 6.32
0.68 Janitor Service Airside 4.59
0.70 Lost Baggage/Out-format Service Airside 21.56
0.72 Janitor Service Airside 1.81
0.85 Inbound Baggage Service Airside 79.61
0.87 Security Service Airside 7.64
0.91 Maintenance Service Airside 5.6
0.95 Janitor Service Airside 4.23
SUBTOTAL 340.58

Airport Operations Coordination


0.34 Circulation 3.93
Centre
Airport Operations Coordination
0.35 ARO/ASID/PA 12.59
Centre
Airport Operations Coordination
0.36 Airfield Manager Office 17.28
Centre
SUBTOTAL 33.8

0.07 Check In Service Landside 147.82


0.10 Concessions' Storage Service Landside 40.5
0.11 Storage Supervisor Service Landside 6.88
0.12 Concessions' Storage Service Landside 7.78
0.13 Circulation Service Landside 20.15
0.15 Electrical Room Service Landside 76.5
0.23 Janitor Service Landside 3
0.26 Circulation Service Landside 33.75
0.27 Security Service Landside 6.67
0.28 Toilets W/M/D Service Landside 3.74
0.29 Men's Locker Room Service Landside 34.01
0.30 Women's Locker Room Service Landside 25.86
0.31 Break Room Service Landside 55.51

120
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

0.32 Smoking Room Service Landside 5.3


0.37 Circulation Service Landside 19.51
0.38 Press Room Service Landside 24.46
0.50 Technical Room Service Landside 8.54
0.62 Maintenance Service Landside 13.71
0.92 Waste Center Service Landside 22.8
0.93 Janitor Service Landside 3.65
0.94 Janitor Service Landside 3.73
0.96 Technical Room Service Landside 3.04
SUBTOTAL 566.91

0.39 Welcome Center VIP/CIP 14.94


0.41 Open Lounge VIP/CIP 42
0.42 Reception VIP/CIP 7.55
0.44 Circulation VIP/CIP 38
0.45 Bar VIP/CIP 10.06
0.46 Toilets Disable/Nursery VIP/CIP 3.33
0.47 Toilets Men VIP/CIP 5.08
0.49 VIP Lounge VIP/CIP 23.96
0.49 Toilets Women VIP/CIP 5.08
SUBTOTAL 150

Level 00 - TOTAL 4570.85

LEVEL 1

1.53 Boarding Pass Airside Domestic Public 27.07


Domestic Departures Security
1.54 Airside Domestic Public 168.26
Check
1.57 Domestic Departures Holding Room Airside Domestic Public 361.7
1.61 Domestic Smoking Room Airside Domestic Public 15.8
1.67 Prayer Room Airside Domestic Public 13.79
1.71 Toilets Women Airside Domestic Public 20.07
1.73 Toilets Men Airside Domestic Public 20.3
SUBTOTAL 626.99

1.02 Boarding Pass Airside International Public 26.43


International Departures Security
1.03 Airside International Public 167.35
Check
1.11 International Smoking Room Airside International Public 17.08
1.18 Prayer Room Airside International Public 20.45
International Departures Holding
1.24 Airside International Public 276.88
Room
1.26 Toilets Women Airside International Public 15.18

121
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

1.28 Toilets Disabled/Nursery Airside International Public 4.39


1.29 Toilets Men Airside International Public 14.16
1.59 Int. Arrival Hall Airside International Public 22.6
SUBTOTAL 564.52

1.09 Circulation Airside Mix Public 76.39


1.60 Mix International/Domestic Corridor Airside Mix Public 285.82
1.63 Toilets Women Airside Mix Public 14.37
1.65 Toilets Disabled/Nursery Airside Mix Public 4.33
1.66 Toilets Men Airside Mix Public 14.16
SUBTOTAL 395.07

1.04 Emmigration Immigration Services Airside 153.3


1.05 Hall Holding Area Immigration Services Airside 16.92
1.06 Emmigration Supervisor Immigration Services Airside 15.98
1.07 Detention Room Immigration Services Airside 13.65
SUBTOTAL 199.85

1.01 Departures Concourse Hall Landside Public 406.72


1.36 Customer Support Office Landside Public 21.45
SUBTOTAL 428.17

1.43 Hall/Reception Offices 36.65


1.44 Administrative Office Offices 24.4
1.47 Airport Director Office Offices 13.45
1.48 Back Office Offices 13.47
1.49 Break Room Offices 13.1
1.50 Administrative Office Offices 21.35
1.51 Toilets Women Offices 6.98
1.52 Toilets Men Offices 9.93
SUBTOTAL 139.33

1.39 Circulation Airport Security Center 9.8


1.40 Airport Supervisor Office Airport Security Center 13.77
1.41 Airport Control Room Airport Security Center 28.43
1.42 Server Room Airport Security Center 11.04
1.46 UPS Airport Security Center 8.34
SUBTOTAL 71.38

1.45 Meeting Room/COSA/Training Room Crisis Management Centre 20.9


SUBTOTAL 20.9

122
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

1.37 Police Reception / Hall Police Station 12.3


1.38 Police Supervisor Office Police Station 10.43
SUBTOTAL 22.73

International Departures Duty


1.08 Retail/Concession/F&B 251.36
Free/Concessions/Retail
1.21 Retail/Concession Retail/Concession/F&B 41.55
Domestic Departures
1.56 Retail/Concession/F&B 131.14
Retail/Concessions
1.77 Retail/Concession Retail/Concession/F&B 12.86
SUBTOTAL 436.91

1.10 International Retail Depo Service Airside 23.02


1.19 Circulation Service Airside 18.51
1.20 Technical Room Service Airside 18.65
1.22 Supervisor Office Service Airside 12.05
1.23 Maintenance Service Airside 17.63
1.25 Technical Room Service Airside 15.02
1.27 Janitor Service Airside 4.08
1.30 Circulation Service Airside 8.6
1.55 Supervisor Office Service Airside 7.87
1.62 Technical Room Service Airside 8.95
1.64 Janitor Service Airside 4.03
1.68 Circulation Service Airside 11.09
1.69 Domestic Retail Depo Service Airside 25.57
1.70 Maintenance Service Airside 11
1.72 Janitor Service Airside 4.17
1.72 Toilets Disable/Nursery Service Airside 4.09
1.80 Janitor Service Airside 4.33
SUBTOTAL 198.66

1.31 Circulation Service Landside 26.75


1.32 Medical Center Service Landside 24.96
1.33 Maintenance Service Landside 24.54
1.34 Toilets Women Service Landside 6.68
1.35 Toilets Men Service Landside 6.55
International / Domestic Departures
1.58 Service Landside 304.27
Holding Room
1.78 Technical Shaft Service Landside 8.57
1.79 Technical Room Service Landside 3.04
SUBTOTAL 405.36

1.12 International Welcome Hall VIP/CIP 14.12

123
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

1.13 International Lounge CIP/VIP VIP/CIP 65.97


1.14 Back Office VIP/CIP 6.07
1.15 Bar VIP/CIP 6.59
1.16 Intern. Lounge Toilets Men VIP/CIP 11.08
1.17 Intern. Lounge Toilets Women VIP/CIP 10.66
1.74 Domestic Lounge CIP/VIP VIP/CIP 32.11
1.75 Domestic Lounge Toilets Men VIP/CIP 8.71
1.76 Domestic Lounge Toilets Women VIP/CIP 8.81
SUBTOTAL 164.12

Level 01 - TOTALS 3673.99

LEVEL 2

2.01 External Technical Area Service Landside 169.28


2.02 Technical Shaft Service Landside 8.54
2.03 Technical Room Service Landside 236.08
SUBTOTAL 413.9

Level 02 - TOTALS 413.9

GRAND TOTAL 8658.74


Table - Summary of Terminal Areas

The following describes the terminal facilities and co-relationships by level:


Level 0 (00.00m)

Figure – Floor plan Level 0 Layout

124
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Land Side Public

Access from the curb side to the Open plaza and Open Concourse Hall to the
terminal for departing and arriving passengers.
Passengers from the car parks, bus station and car rental areas will also access this
Open plaza.
Several Concessions spaces are distributed along the Passenger Terminal Building,
and create a physical barrier that defines the Concourse area.

Figure – Departures Curb Side Layout

The check-in concourse is a Clean, clean space with 'walk-through' check-in


counters to ease passenger flows and assist way-finding.

Figure – Check-in Layout

125
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

The VIP/CIP services have a dedicated curb side and a privilege access for the
Passenger Terminal Building. It‘s located centered with a welcome centre service
allocated.

Figure – VIP Layout

The vertical Circulation for Departure Hall will be located centered on the Open
Concourse Hall.

Figure – Vertical circulation Layout

The Arrivals Concourse Hall is located on the other end, opposite from the Check-
In area, and will have a direct access to the Arrivals curb side.
Access from the curb side to the Open plaza and Open Concourse Hall to the
terminal for arriving passengers.

126
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure – Arrivals Curb Side Layout

Land Side Services

The Airlines Counters and their Offices work directly to the Check- in Area.
The Airport Employees have direct Entrance/Exit access on this Concourse Hall
Area.
The Customs Services Offices will be located on the Open Concourse Hall.
The Immigration Services Offices will also be located on the Open Concourse Hall.
There will be a dedicate road access for servicing maintenance and Waste
collection.
The Emergency Service Accesses are able to work on VIP access, Service Access
Area and can also access any part of the building.

Figure –Service Access Area Layout

127
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Air Side Public

International

The International Arrivals Hall on ground floor collects arriving passengers from
contact stands and remote stands.
The Immigration area provides a passenger check point control with support
areas for closer evaluation.
The passenger can reclaim his belongings at the baggage reclaim hall Access to
Make-up Baggage Inbound Area.

Figure – International Arrivals Layout

Domestic
The Domestic Arrivals Hall on ground floor works also as Departures Hall for
some remote stands that will operate on the apron (Aircraft type B and smaller).
After the passengers arrive to the baggage reclaim hall and claim their
belongings, they will pass through a control security post and end on Land side
Arrivals Concourse Hall.

128
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure – Domestic Arrivals Layout

Air Side Services

The staff areas allocated to Operational Service Area are on the ground floor
level, with controlled links to the Air side. After they enter the Airside exterior,
they can access to Apron, Clearance and Make-up Baggage Outbound Area and
Make-up Baggage Inbound Area. Dedicated circulation can access to Airside
Customs Service Support, Immigration Service Support and Quarantine Services
for International Passengers. The AOCC (Airport Operations Coordination Centre)
will be located in direct contact to the Apron, allowing a clear view. This area is
the nerve centre of the airport, being the focal point of contact for all airport
operational issues other than Air Traffic Control. The AOCC operates according to
the procedures of the Aerodrome Operations Manual and incorporates the
functions of the Apron Control Centre. The main functions of the AOCC are:

 apron management (―follow-me‖ and other airside operations vehicles


supervision and coordination);
 ATC liaison;
 airfield work-in-progress coordination;
 flight information, coordination and consistency verification;
 stand allocation;
 check-in allocation;
 baggage reclaim allocation;
 passenger terminal operations coordination

The AOCC will be equipped with suitable radio communication, telephone and
information media. A suitable aerodrome and surrounding airspace (approach)
radar feed will be provided to display an image of the aerodrome and provide
accurate traffic situational awareness, arrival estimates and stand allocation
information. Suitable operational consoles are required for all working positions.
Common operational reporting and information sharing should be introduced
throughout the airport to allow collaborative decision making (CDM) between

129
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

airport services providers and between AOCC, ASC and ATC to be implemented,
according to the Requirements.

Level 1 (05.00m)
The following figure is the floor plan level 1 layout

Figure – Floor plan Level 1 Layout

Land Side Public


Departure Concourse Hall connected to International Departures and Domestic
Departures. The public Concourse is a Clean, clean space with 'walk-through' to
easy passenger flows and assist way-finding. The Passenger Service Support Area
will be located on Departures Concourse Hall. One Concession space is located at
the centre.

Figure – Departures Hall Layout

130
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Air Side Public

International

The passenger flow for International Departures will oblige going through three
control types before arriving to the dedicated Airside Holding Rooms. The
boarding pass control is the first barrier for controlling this passenger flux, and
this area will define and secure the barrier between Airside and Landside. After
the boarding pass stage, the passengers will be conducted to Security Check
corridor for hold-on baggage and personal X-ray screening; this will provide the
Security Safety Requirements.

The final barrier for passenger flux is the Emigration Services that will make the
passenger sorting. This Immigration area provides a passenger check point
control with support areas for closer evaluation. When the International
Passengers complete this procedure flux, they arrive to retail /duty-
free/concessions‘ dedicated Area, and from this area on they‘ll have direct
contact with the gate holding rooms, VIP/CIP lounge and supporting areas.

Figure – International Departures Layout

Domestic

The passenger flow for Domestic Departures will oblige going through two control
types before arriving on dedicated Airside Holding Rooms. The boarding pass
control is the first barrier to control this passenger flux, as this area will define
and secure the barrier between Airside and Landside. After the boarding pass
stage, the passengers will be conducted to Security Check corridor for hold-on
baggage and personal X-ray screening; this will meet the Security Safety
Requirements. When the Domestic Passengers end this procedure flux, they will
arrive to retail /concessions dedicated Area, and from this point on they will have

131
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

direct contact with the gate holding rooms, VIP/CIP lounge and supporting areas.
The Domestic Departures Area and the Domestic Arrivals Area for contact Stands
will share the same space. This area and its support facilities are dimensioned to
receive both passengers‘ fluxes. When the Domestic Passengers end this
procedure flux, they will arrive to retail /concessions dedicated Area, from this
they will have direct contact with the gate holding rooms, VIP/CIP lounge and
supporting areas.

Figure – Domestic Departures Layout

Mix Areas

The Mix Holding Room that exists between the International Departures Airside
and the Domestic Departures Airside will be attached as the passenger demand
so requires, because it can be closed and secure the area for the dedicated
request. This facility has all the support areas that are required for possible
demand. The Mix Corridor is able to connect each contact stands with Departures
and Arrivals Hall. The ability to do so is the Airport Operations‘ responsibility and
management. Incorporated barriers will provide this segregation flux.

132
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure – Mix Arrivals/ Departures& International/Domestic Corridor


Layout

Land Side Services

The Police Station will be accessed on Departures Concourse Hall and will support
the Oecusse-Ambeno International Airport, in particular the Passengers Terminal
Building. The ASC (Airport Security Centre) will be accessed on Departures
Concourse Hall, and it will work with all Airport Security surveillance. It will be
closely linked to AOCC (Airport Operations Coordination Centre) and ATC. The
Administrative Airport Offices will be accessed on Departures Concourse Hall, and
they support all the personal and logistics activities, and they will also have
training rooms, support offices and the CMC (Crisis Management Centre).

CMC (Crisis Management Centre)

In case of emergency on/or in the vicinity of the airport, the airport follows its
Airport Emergency Plan (AEP), fully compliant with ICAO DOC 9137. The AEP is
designed as a coordinated operational document detailing duties, responsibilities
and specific procedures to be followed and is to be used in conjunction, as
necessary. A fixed and dedicated Crisis Management Centre (CMC) is part of the
AEP facilities, and must be available for use during an emergency. It is the
backbone for coordinating the airport‘s procedures, for the response of the
airport‘s different agencies and services and those agencies in the surrounding
communities that could be of assistance in responding to an emergency.

The CMC is located adjacent to the Airport Administrative Services and Security
Centre, in a central location at the airport but with restricted access. This facility
should accommodate each of the airport key stakeholders, including Fire and
Rescue Services, Emergency Medical Services, Police, Civil Protection, Customs,
Government Security, surrounding area local authorities, Airport Duty Officers,

133
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

airline representatives, ground handling representatives and other key


stakeholders.

The CMC has all the necessary Video Conferencing, media Infrastructure,
telephone / radio communications to enable the control, co-ordination and liaison
during an emergency situation (or exercise). Secured telephone lines (and
possibly satellite phones) are required for emergency situations.

Air Side Services

Several support areas can be allocated for maintenance service and closer depot
facilities for the retail/duty-free/concessions services. These areas have restricted
service access.

Level 2 (10.00m)

The following figure is the floor plan level 2 layout:

Figure – Floor plan Level 2 Layout

Land Side Services

This is a technical floor with restricted service access, where the several
mechanicals systems that support the Passenger Terminal Building will be
located, as well as where the roof structure can be accessed for maintenance.

7.7. Building Systems

The aim is to produce an Airport Terminal that:

 Provides a safe environment for staff, passengers and visitors alike;

134
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 Provides a high quality internal environment that facilitates ease of


movement through the terminal;

 Minimizes level changes in the passenger journey;

 Minimizes capital cost and construction program by extensive use of


modularity and pre-fabrication;

 Is flexible, allows changes and expansion both in short and long term;

 Provides a high level of reliability, and includes redundancy for critical


applications;

 Is straightforward and cost-effective to maintain;

 Represents international best practice;

 Is in accordance with all applicable local and international standards;

 Minimizes overall energy usage by a combination of passive and active


technologies, thereby reducing operating costs of the development.

Introduction

Our design for the mechanical, electrical, public health and fire suppression
systems will provide a servicing solution that economically delivers a high quality
internal environment, is functional and flexible and provides all the services
required for a 21st Century Airport Terminal.

All systems and equipment selected will be appropriate to the local conditions,
and compatible with the local market. The services will be designed in such a
way as to flexibly respond to the ever-changing demands of an airport, in
particular the retail and internal spaces. They will also respect and be consistent
with the architectural spirit of the project.

Our design aims to minimize the overall energy consumption of the new complex
by a combination of a number of approaches:

 Energy-optimized design of main plant and distribution, to ensure that no


energy is wasted in generation or distribution;

 Passive design optimization to minimize heating, cooling and electrical loads;

 Use of innovative technologies where proven and appropriate to minimize


energy consumption.

The design for the new buildings will be in accordance with all relevant local and
internationally recognized codes and standards.

135
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Sustainability in the Mechanical and Electrical Design

Background

The airport environment, sustainability and the implementation of renewable


energy sources are becoming key factors in the design of Mechanical and
Electrical Systems. The design must tackle these issues through experienced
designers who need to understand the particular constraints and challenges of
Airport Terminal design.

Our Approach

Amongst the many opportunities at Oecusse-Ambeno International Airport, the


following have been identified:

Daylight

Daylight management – The geographical location of the Airport provides a


natural asset, which needs to be exploited. The approach will be to optimize the
skylight design. It‘s positioning, percentage of glass openings, orientation and
glazing performance must be assessed to maximize their benefits. Some of the
techniques that need to be employed are described below.

A technical assessment on the daylight performance in the terminal concourse


should be carried out to determine the daylight distribution and the extent of sun
penetration across the space. The results of these should be utilized in
identifying energy saving opportunities by means of daylight linked lighting
controls and potential glare issues across the space, where information display
screens may be located.

The integration of natural and artificial light is another element in the overall
lighting Provision of optimal visual environment, drama, daylight control and
environmental protection in terms of energy saving, are all key lighting issues
that need to be addressed.

The influence of changing natural light, the control and performance of artificial
lighting can affect the visual perception of a space for better or worse. Adopting
the correct lighting strategy is an important feature of any building design
process. Getting the right strategy involves making the correct decisions on how
the natural light enters the building, how useful it will be, how it will reveal the
interior and influence the spatial configurations.

Variations in external and internal daylight illumination levels occur through each
day, and throughout the year, because of the movement of the following:

136
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Air Conditioning

Air Conditioning – The extent and capacity of Air Conditioning (AC) required
needs to be examined. It is appreciated that the climatic conditions within East
Timor require AC to be an integral part of the building design; however, the goal
must be to reduce the carbon footprint of the building. The environmental criteria
and the need to condition all spaces need to be challenged. For example,
transitory spaces where the passengers first arrive from outside may not require
full AC but instead utilize intermediate ventilation (such as roof fans). The
maximum design conditions for which the M&E systems are designed will also be
challenged.

AC plant is rated according to the normal practice of identifying a ‗design day‘.


This is often based upon a full terminal (say where a number of planes have been
delayed) and high ambient temperatures. This leads to plant being installed, that
is often rarely needed, or working at a low to medium loading. This type of
operation is inefficient both in terms of capital and operational costs. The design
day concept will be challenged so that more questions can be asked of the airport
management team to consider what a realistic worst case is. Perhaps during
these exceptional circumstances comfort conditions could be relaxed. Natural
Ventilation is normally is effective in an airport terminal environment, on the wide
circulation space, and external noise issues, however in exceptional
circumstances (a design day), it might to possible to identify areas that are not
critical and could be shut down, without effecting the terminals operation.

An examination of the water table may allow the design team to consider
alternative means of terminal cooling. Ground source cooling is an established
technology and this is Cleanly an option here. The key, however, is to understand
how to make best use of this resource. Terminal buildings tend to have high
ceilings and open concourses. The normal approach is to air condition the lower
parts of the concourse zone- say the first 3 meters (where the people are) and
leave the upper roof area untreated. Ground water cooling could be used to
supplement the normal central cooling system. It may practical to introduce floor
cooling to the concourse areas. This needs to be explored. Ground water cooling
would be extracted via wells (either directly or indirectly), passed through heat
exchangers and then circulated through under floor cooling pipes. This approach
is possible because open concourses do not have raised floors, nor carpet
finishes. A supplementary air system would be required. The circulation pumps
lend themselves to being supplied with energy from photovoltaics, as power
demand peaks when the sun is hottest and brightest. These technologies should
be developed and their advantage explored.

137
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Energy Efficiency

The types of M&E systems selected will make use of the latest advances in
energy efficiency, including variable speed motor drives, variable
Air/Displacement Air Systems, electronic commutative direct current motors,
Building Management System controls, variable volume water systems (cooling),
water saving valves and taps including passive movement detectors.

Energy Conservation

The design will address the need to conserve the use of energy (electrical) in the
operation of the building. Energy use will be reduced by adopting the following
measures:

 Use higher internal design temperatures in summer for cooling.

 Serve public areas using displacement systems.

It is proposed that renewable sources of energy be applied on the site.

 Solar water panels would be associated with possible domestic hot water
generation, emergency lightning and would be located on a roof.

Utilities Connections

The proposed utilities connections are as follows:

 Rainwater: it will be delivered to the run-off drainage network.

 Water Supply: will derive from the potable water network.

Electrical Supply

The Airport Power Network will provide one supply of medium voltage power. This
line will operate always, because the system provided will have an emergency
supply on the system source.

7.8. Baggage Handling


Overview

The purpose of this section is to provide details of the proposed Baggage


Handling (BH) concept. The BH concept within the Terminal building has been
designed to provide a level of flexibility and expandability to accommodate
growth and demand when additional gating is required. In addition to capacity
requirements, the BH has been designed to meet targets to enable the in overall
perspective, a minimum waiting time and performance standards.

138
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Design Process

The baseline principle design for this concept is full manual procedure on baggage
handling. The design process applied in order to develop the proposed BH
concept is illustrated below.

Baggage Outbound Process

The following figure summarizes the baggage process on Departures:

Figure – Baggage Outbound Process Diagram

Check-in facilities are located at level 0 (0.00), as indicated on Terminal plans.


Each "standard bag" check-in desk (independent of function, e.g.
Economy/Premium or bag drop) will consist of 3 conveyors - weigh, label and
dispatch. The dispatch conveyor will feed bags into collecting belts to be
transported to the Hold Baggage Screening (HBS) posts. Any Non Conveyable
items which cannot be transported via this system will be manually handled for
onward processing. The Early Bags (EB) will be stored in a dedicated area, but for
which a Make Up position has yet to be designated. All bags that enter the EB
area will have been Cleaned by the HBS process. The Make Up area is located at
Airside, where bags will be offloaded from the baggage system and on to Airside
vehicles.

139
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Baggage Inbound Process

The following figure summarizes the baggage process on Arrivals:

Figure – Baggage Inbound Process Diagram

The arrivals process consists of bags being carried by trolleys and offloading
them directly to reclaim baggage carousels. Any Non Conveyable items which
cannot be transported via this system will be manually handled for onward
processing and will be collected in a support facility. Each reclaim baggage
carousel can accommodate an Aircraft Type C full capacity processing.

7.9. Passenger Terminal Logistics


Servicing Logistics

Adequate provision of infrastructure for the distribution of retail and non-


passenger operations is vital for the success of Oecusse-Ambeno International
Airport. This section outlines the assumptions regarding the servicing operations
within the building, and consequential infrastructure requirements. The delivery
strategy encompasses the logistics for the movement of all items required in the
airport (e.g. retail goods, maintenance equipment, airport and airline supplies) to
the service area, the provision of loading and unloading facilities and the
distribution of items from the loading docks to landside and airside destinations
via storage/pre-retailing facilities if required.

Stakeholders

A wide variety of stakeholders will receive deliveries, and distribution of these


deliveries to their intended destination must be accommodated. The following
provides a check-list of the likely stakeholders distribution needs within the
terminal, in particular noting items which have specific handling requirements.

140
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Airlines

Airlines will regularly receive deliveries of stationary – boarding cards, ticket


wallets, timetables, etc., and occasionally receive deliveries of furniture such as
new desks, chairs and deliveries of IT related products such as printers,
computers etc.

General Retail Deliveries

The exact number of retail deliveries will depend on the number and type of
concessionaires renting the retail units, for example if a concessionaire has
multiple units there will be fewer deliveries than if all the units are let to
individual tenants. Special attention should be given to the following for which an
alternative delivery process may be necessary:

 Newspapers – time critical

 High value goods / currency.

Food & Beverage Retailers

The exact number of food and beverage deliveries will also depend on the
number and type of catering retailers, for example a fast food outlet has different
replenishment requirements than a small coffee shop.

Attention must be given to ensure that cellars are provided for bars and suitable
links for possible feed lines between the cellar and service point. (The precise
location for bars will not be finalized until detailed design, however at this stage it
is important to ensure that there is capability within the building to enable
operations of this nature.) Special attention should be given to the following for
which an alternative delivery process may be necessary:

 Kegs & Bottled Gas

 Cooking Oil (in particular removal)

 Bulk Chilled Items (e.g. drinks)

Retail Fit Out & Maintenance

It is assumed that retail fit out and maintenance will predominantly occur out of
hours. Lifts should be identified and sized to accommodate most large items
necessary for maintenance and fit out.

Waste

The movements of waste within the building and use of the service area by waste
collection vehicles is below. Based on the estimated waste generation calculations
above the number and type of receptacles are detailed in the following table:

141
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Equipment Landside/Airside

1 x 10.5 m3 compactors (Cardboard, General Waste,


Compactor
Organics, DMR)

Balers 2 balers (Cardboard and wrapping plastic)

Skips 1 x 14 cu. yd. skip (WEEE, wood, metal)

Others Electronic Waste Store.

1 x Glass Bottle bank.

Bin wash area

Waste oil bonded area

Household Hazardous and maintenance store room

Table - Waste Equipment

Cash Deliveries

Deliveries and collections of cash are assumed to occur out of hours, when
security risks are minimized.

Energy Centre

In addition to deliveries to the main terminal building, the service area may have
to be used for deliveries and access to an energy centre. It should be ensured
that access to the energy centre is possible at all times and additional provision
to enable vehicle access to particular rooms of the building will be incorporated
into the design. The detailed requirements relating to non-standard access of
the energy centre (for equipment replacement, etc.) should be covered
separately under the requirements of the energy centre.

Emergency Services

Emergency services will need access to all areas of the airport.

Passenger Areas

Conflicts between passenger flow and goods movements should be minimal, and
access routes through public areas should be avoided where possible. It is
acknowledged that passenger areas will need to be crossed by goods delivering
to island units and any units in the pier. Suitable top-up storage should be
provided in the vicinity of these units to ensure that bulk replenishment can occur
out of hours or during quieter periods.

142
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Trolley Logistics

The details of the trolley recirculation strategy are below. The operational
objectives for the trolley strategy are as follows:

 To ensure that all passengers have access to a trolley in the right place at
the right time;

 To provide trolley buffer areas to minimize impediment to passenger


circulation;

 To ensure that trolley re-circulation is efficient and effective;

 To ensure that trolley re-circulation minimizes impediment to passenger


circulation; and

 To support operational efficiency, i.e., optimization of trolley fleet, operations


and personnel.

Segregated routes will be provided for the delivery of goods, waste removal and
trolley movements. The delivery and servicing logistics should not, therefore, be
affected by the movement of trolleys.

Departing and arriving passengers will collect trolleys from within the curb side or
car park and in baggage reclaim hall. They will proceed to the arrivals or
departures curb or the car park (which they can get to by crossing the road at
level 0.0). Trolleys will be left at the check- in, car park or at the arrivals curb.

Assumptions

 90% of passengers carry bags;

 90% are economy passenger, 10% are business or first class passengers;

 70% of economy departing and arriving passengers use a luggage trolley;

 70% of business class departing and arriving passengers use a luggage


trolley;

Trolley Corrals

Trolley corrals or buffer areas will need to be provided in areas where passengers
are likely to collect trolleys or deposit trolleys.

A wide range of factors affect the required size of each buffer area, for example:

 Staffing;

 Location and distribution of buffer areas;

 Frequency of replenishment and removal; and

 Flight schedules.

143
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

The following is an estimate of the maximum areas required in 2050 as we


cannot assume instantaneous pick-up and drop-off of trolleys, in reality it is
unlikely that those about to be collected will be there at the same time as those
just deposited. An allowance of 9m² for every 50 trolleys should be provided such
that, based on the theoretical maximum stock for each location, the buffer areas
are:

Figure – Typical trolley stack dimensions (in mm)

The size of the buffer areas will also be dependent on the type of trolleys used;
trolleys and trolley stacks vary in size. Trolley corals at each location should be
dispersed, for example, there should be multiple locations on the departures and
arrivals curbs, the car park corals for departing and arriving passengers can be
the same location, trolleys can be stored in between baggage belts in the arrivals
reclaim hall.

Material Handling Equipment

It is assumed that the retailers will provide their own materials handling
equipment. The individual retailers will be responsible for providing and
safeguarding their own pallet trucks and delivery cages.

144
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Retail Storage

Retail storage at airports should generally be 24 – 26% of sales floor area,


however this can be reduced to 16 – 18% of sales floor area if a consolidation
centre is used. A consolidation centre could also reduce waste management
requirements.

Vehicle Generation

Vehicle Types

The following provides a brief description of the vehicle types that may deliver to
the airport:

Vehicle Type Vehicle Characteristics

2 Ton,
Commercial Van
Vehicle length 6m

3.5 Ton,
LGV – Light Goods Vehicle
vehicle length 6m

7.5 Ton,
MGV – Medium Goods
Vehicle
vehicle length 8m

Figure – Vehicle Type

Infrastructure Requirements

Service Yard

The service yard will need to be a gated facility with a gatehouse, ensuring that
only those vehicles delivering to the airport are given access and that the loading
bays are managed. A managed delivery service whereby deliveries have to be
booked in stating time and date of delivery will also enhance the security of the
loading area.

Additional Structural/Architectural Requirements

Corridor widths must be at least 3m to allow for a two-way flow of traffic (in
particular if route is proposed as a primary fire exit route) and 2,30m high.

Areas in which materials handling equipment is used need to allow sufficient


space for this equipment to turn. Service routes should have a gradient less than
1:12 and there should be no steps or curbs.

145
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

All floors will need to have a suitable finish to ensure that:

 Wheeled containment units can be pushed easily along the entire route;

 Handling equipment is able to move along the entire route;

 Weight of goods loads and handling equipment can be supported.

7.10. Terminal Area Security


Introduction

Terminal protective security divides into two Cleanly defined areas - landside and
airside. The required security strategy for each area differs markedly in its
protective measures. A specific threat and risk analysis would assist by focusing
measures at meeting precise circumstances that could impact on the terminal's
landside and airside security operations. However, at this early design stage it is
not crucial to consider specific risks to the business. The consideration of generic
factors is acceptable, in absence of a full analysis of the threat.

Spatial considerations are dealt with specifically in other areas of this report.
However the security rationale that underlies the design decisions is outlined here
and expanded where it is important to understand the security imperatives
behind the design principles and spatial allocation.

Landside security

Aims

This section is aimed at the landside areas of Oecusse-Ambeno, including vehicle


access and related security issues. It is based on an outside-in structure as
follows:

 Outside the terminal – Approach roads.

 Terminal forecourt – The thirty meter Clean zone.

 Terminal external pedestrian area – The pedestrian area immediately in front


of the terminal.

 Inside the terminal – Internally, as far as the search comb.

The objective of this section is, primarily, to ensure that the Passenger Terminal
Building provides effective protection for high density public areas from the risk
of attack foremost from Vehicle Borne Improvised Explosive Device (VBIED) and
Person Borne Improvised Explosive Device (PBIED).

Likely Methods of Attack

A broad and diverse range of landside likely methods of attack can be identified
as follows (not in order of threat value):

146
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Vehicle Borne Improvised Explosive Device (VBIED):

 parked near the terminal,

 encroaching through gaps in incomplete/ineffective barrier,

 being driven into the terminal building,

 entry by deception – including by a Trojan, as in ‗adapted livery‘ or stolen


vehicle,

 authorized driver or guard under duress, and

 Driver (unknown) driving authorized vehicle.

Person Borne Improvised Explosive Device (PBIED). This includes;

 strapped on body device,

 Carried device (rucksack, bag, briefcase, etc.),

 Deposited device (among people, in bins, etc.),

 Carried under duress, and

 Host (device carried unknowingly).

Principles

In establishing the principles, it is essential to recognize the need for security


requirements to be proportionate and to allow for the correct balance to be struck
between the needs of aviation security, safety, operational requirements and
passenger facilitation. The principles upon which this section is based are as
follows:

 Designing in security, designing out, to the best extent practicable, risk and
vulnerability;

 Physical prevention – ensure an agreed stand-off distance of vehicles;

 Risk assessment and blast mitigation – ensure appropriate building


infrastructure design;

 Access control – ensure a system of authorized vehicle access adjacent to


building infrastructures;

 Reduce fragmentation in areas of high density public areas.

Key Recommendations

The key recommendations in this section are as follows:

 For the terminal building - all vehicles should be kept at least thirty meters
from terminal building, using an effective physical barrier in accordance with
appropriate standards. Because the distance is less than the recommended,

147
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

the façade should have the capacity to resist sufficiently to a blast mitigation
for light goods vehicles.

 Car parks (both public and staff) will be located at least fifty meters from
terminal buildings, and separated from the vehicle exclusion zone by using
an effective physical barrier in accordance with appropriate standards.

 The speed and route of all vehicles should be managed, as far as is


practically possible, to reduce their possible kinetic energy and impact
capability.

 Heavy Goods Vehicles will require a control methodology to prevent


unauthorized access to the under croft. It is an expectation that these
vehicles will not gain access to the terminal frontage and have a process by
which they report to a control point, where their entitlement may be
validated and then either accepted or rejected, dependent on the legitimacy
of the vehicle. Measures will apply equally to inbound and outbound roads.
This process can be stepped so that it fits with all levels of threat from low to
critical, allowing the terminal to operate under all threat levels without the
need for exceptional measures.

 Lighting should be fit for purpose and should provide coverage of all relevant
areas (including all critical and controlled zones and vehicle routes).

 CCTV should be fit for purpose, and should be correctly sited to provide
coverage of all relevant areas (including all critical and controlled zones and
vehicle routes) and should be compliant with relevant legislation. Security
should be reflected correctly in the terminal's CCTV strategy.

 Terminal external pedestrian areas is designed to attract congregation of


high density numbers of the public, e.g. retail outlets such as coffee shops,
should be located inside the terminal but this areas will be with additional
protective measures employed.

 Mitigation should be included, and planning designed, to provide defense,


where possible, against person borne improvised explosive devices.

 Terminal buildings should be built with effective bomb mitigation. This should
include standards for glazing and the recommended construction of fixtures
and fittings.

 Signage and audio/visual communications should be effective for public


safety.

 Alarm systems should be effective and should have a correct response


procedure.

Deliveries to Airport – Separation from Public Routes

Delivery vehicles are to be kept away from the terminal forecourt and handled
via a dedicated delivery facility and control points, reached by a separate vehicle

148
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

route. This particularly applies to (readily available by hire and common


livery/color) large delivery vans and large HGV‘s, particularly fuel carriers. The
airport must have a suitably located access point for deliveries.

Vehicle Access Control Posts

Vehicle access control posts should be located away from the terminal, so as not
to cause queues which will obstruct regular traffic flow or block road systems in
the event of an emergency evacuation, and should be of sufficient capacity to
meet demand. Where possible, a rejection lane should also be made available, to
prevent vehicle build up.

Such posts, themselves, should be protected against vehicle impact and deny
access to any controlling equipment, whilst in silent or working hours. Protection
must be put in place at the exit end of controlled lanes.

Restricted and VIP Routes, Reception & Facilities

Generally, these are used by emergency services, airport operations and for VIP
reception. The general thirty meter exclusion zone applies for all vehicles.
However access within this zone is appropriate for specific vehicles for a specific
purpose, such as emergency action or airport operations. Here, access must be
controlled by, for example, verification, and transponder, swipe, token or pin that
deactivates a proportion of the physical Barrie ring. These routes should be
planned in consultation with the local authorities.

Car Parks

The locations of car parks are determined by the site footprint and the
operational needs of the airport. However, the car parks are also located so as
not to compromise security.

Car parks are to be located at over fifty meters from terminal buildings and high
density public areas. There are benefits to be gained from the installation of
CCTV/ANPR equipment in car parks at the point where tickets are obtained, as a
deterrent against both terrorists and general crime. This should be discussed with
the appropriate authorities.

Landscaping and Bunds

Correctly sited bunds and other landscaping features are beneficial to aviation
security, for example, by acting as vehicle speed restrictors or preventing access
to vehicles.

It is essential that they are constructed from suitable granular material, avoiding
the use of rocks or rubble, with the bund profile and dimensions being key. The
use of loose rocks or rubble is to be avoided as they add considerably to the

149
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

detrimental secondary effects of an explosion. No landscaping or bund should be


sited as to provide a ‗ramp‘ possibility.

It should be noted, however, that bunds do not always provide protection from
the overpressure generated by large explosive devices, and their effectiveness is
heavily dependent on their height, etc., relevant to terminals and other buildings.

Advancements in planters can make them a feasible and cost effective barrier.
Trees should not be considered to provide a robust barrier, unless they have been
evaluated to be of sufficient diameter and depth. Features such as roads or
service tunnels which pass under, over or through terminals, or airside/landside
boundaries should be secured to prevent unauthorized access.

Where plant and maintenance facilities are placed landside, access should be
controlled and secured. Ducting, piping, cabling or inspection panels are to be
placed so that they do not afford access through to the airside areas.

Lighting

Security lighting is essential and should be taken into account for all vehicle
routes, adjacent perimeters and terminal forecourt area. It should provide
illumination of all critical operational areas to enable effective patrols and
surveillance. Lighting type and luminosity should be compliant with the
appropriate recommendations.

Closed Circuit Television (CCTV)

CCTV is not a ‘defensive‘ type measure in itself, but an important surveillance


‗tool‘ that, if correctly managed and monitored, can identify or pre-empt a
possible threat to an area and alert the need for an appropriate response. CCTV
should be strategically planned, in conjunction with relevant Agencies for a
‗joined up‘ approach to risk management. The areas requiring surveillance should
be determined by a vulnerability assessment, taking into consideration the
current local threat information and the level of mitigation required.

With risk starting at the point of entry, CCTV can be utilized and deployed,
simplistically, in layers:

 ANPR for approaching vehicles;

 point of entry to airport forecourts;

 booking halls;

 search and entry areas into a RZ; and

 Passenger transit routes to flights.

150
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

In non-public areas, CCTV can be utilized for:

 security to flight departure;

 aircraft stands;

 airport operational service areas; and

 Access control.

CCTV can be deployed with un-manned alarmed systems such as Perimeter


Intruder Detection (PID) fitted for criminal movement/action intelligence, and can
provide ‗electronic‘ patrols.

It is effective, when correctly deployed, as a ‗post analysis‘ tool. Particular care


should be taken to ensure recorded images are of sufficient quality.

CCTV is most suitable on large airport sites where foot patrols are time reliant.
CCTV systems, to be effective, require constant manning, maintenance and
upgrades, and should comply with appropriate regulations. CCTV cannot always
be considered ‗preventive‘. It has some deterrence value, but on its own is no
substitute for robust protective security measures.

Signage and Audio Visual Communications

Good signage, at an early stage, will Cleanly direct traffic and passengers to their
required areas and assist in ‗traffic‘ flow. Signage, though, is not a defense to a
terrorist or criminal, intent on diverting their course. Provision of emergency
service signage is important to aid a timely response and arrival. Adequate
provision of audible communications is important, not only for ‗normal‘ operations
(public announcements), but also for emergency or evacuation situations, which
may require communication with passengers or staff in areas such as car parks.

Consideration should be given to communications being effective, with temporary


or long term loss of electrical power. Furthermore, consideration should also be
given to the use of ‗secure‘ communication devices, to mitigate against its
potential to be used/overheard by the ill-disposed.

Terminal Forecourt

Key planning objectives:

 Vehicle drop-off areas are kept away from high density public areas;

 Non-Authorized vehicles are kept a minimum of thirty meters from high


density public areas;

 The effective use of physical barriers which are fitted and operated in
accordance with appropriate Standards;

151
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 The effective managed access of authorized vehicles to the terminal


forecourt.

Vehicle Lanes and Drop off Zones

Vehicle Lanes and Drop-off zones for buses, taxis and members of the public‘s
vehicles, inherently, will be placed as near to airport terminal frontages as
possible, with respect to each vehicle group's threat profile. The nearest a vehicle
lane or drop-off zone will be is a minimum of thirty meters from the terminal
frontage, with the thirty meter vehicle exclusion zone separated by an approved
physical ‗barrier‘ in accordance with appropriate standards. This reduces the
likelihood of an attack as the potential for mass casualties and infrastructure
damage, and therefore publicity for the perpetrators, is very much reduced.

In accordance with usual security requirements, vehicles lanes and drop-off


zones should be regularly monitored to prevent drivers parking and leaving the
vehicle unattended. CCTV and physical patrolling may fulfil this requirement.

The way as the airport infrastructure might cope with additional measures should
be taken into consideration, for they may have to be applied at times of
heightened threat, for example where the threat rises to ‗critical‘. These could
include, for example:

Closing any Authorized Vehicle Lane with less than a thirty meter stand-off
distance from the terminal building or other critical infrastructure, e.g. air traffic
control tower.

Moving public vehicles even further afield from outside of the thirty metre zone
to a suitable alternative location.

Design and Use of Vehicle Barriers - Against Vehicle Borne Improvised


Explosive Devices (VBIED’s)

Vehicle barriers are essential as a first line of defense against potentially


devastating VBIED attacks. If improperly designed, however, a vehicle barrier
system may fail to prevent the intrusion of a threat vehicle, or its design may add
to the fragmentation in the blast. For active barriers, whichever type is used, it
should operate with a form of secondary control – guard, token, swipe or pin
activated, where legitimate vehicle access is required.

The following is an overview of the process for the selection, installation and
operation of vehicle barriers. The main considerations include a vulnerability and
risk assessment, an effective and appropriate design and barrier selection. The
assessment should determine whether the asset is a ‗potential target‘ for
terrorists.

152
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Risk Assessment

The first step in the design process of a vehicle barrier system is a vulnerability
assessment of the asset to be protected, taking into consideration current local
threat information.

The assessment should include the following in the analysis: a description of any
threats to the asset, including threats with a low probability of occurrence but
high consequences, the identification of assets requiring protection and an
assessment of their potential vulnerabilities; and also an estimate of both direct
and indirect losses that could result from the destruction of or damage to these
assets. A bomb-blast analysis, or assessment, should also be included.

Design

Once the vulnerabilities are identified, the design process for the vehicle barrier
system can be completed.

Barrier types

Barriers can be active or passive, fixed or movable, and they may be categorized
as the following: bollards, rising barriers, sliding gates and portable barriers.

Active and Passive

Vehicle barriers are categorized as either active or passive. Active barriers


require action- either by people or equipment (swipe, token, and transponder or
pin verification) - to be raised and lowered, or moved aside to permit vehicle
access and egress. These systems include bollards, rising barriers, and gates that
are operated manually, pneumatically, or by hydraulic power units. Active
barriers could be used at locations such as a terminal frontage, airside entrances,
parking, or loading area entrances and should be located as far from the critical
asset as practical.

A passive barrier has no moving parts. Examples include fixed bollards,


guardrails, ditches or earth bunds, trees, planters, water features, walls, raised
planting. They should be designed to deny access to an asset, building or
controlled area. It makes sense to use active barriers at entrances and passive
barriers surrounding the rest of the asset building.

Project design takes account of pedestrians and emergency vehicles. It is also


important for a facility, with a standoff distance of fifty meters or more, to create
an easy access route to the building for emergency and maintenance services.
The design and installation of ‗active‘ barriers should include an ―airlock‖ system
to prevent an un-authorized vehicle tailgating an authorized vehicle.

153
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Fixed or Movable

Depending on how they are made and used, both active and passive barriers can
be fixed or movable. A fixed barrier is one that is permanently installed or
requires heavy equipment to move or dismantle it. Examples of these include
hydraulically operated wedge-type barrier systems or bollards set in concrete
foundations. A portable or movable barrier system is one that can be relocated
from location to location. This type of barrier may also require heavy equipment
to move it.

Bollards

Fixed bollards are typically metal or metal/concrete posts that are embedded into
a reinforced concrete foundation and/or a steel sub-frame. Retractable bollards
can be operated manually or automatically with a hydraulic pump unit. Spaced a
set distance apart (no more than 1.2m), bollards do not obstruct pedestrian
traffic and can be aesthetically pleasing. To blend with any environment, they can
be equipped with a sleeve of aluminum, stainless steel, plastics or stone
(sponsored company logos and crests can also be incorporated onto the sleeves
which may offset cost of purchase and maintenance).

Wedge/Plate Barriers

These barriers are rectangular steel plates housed below the roadway that rise
from the surface of the road. Plate systems can be shallow or surface mounted so
as not to interfere with buried utilities.

Sliding gates

The sliding gate uses a cantilever or track gate design. When in the closed
position, the gate leaf locks into steel buttresses that are embedded in a
foundation on both sides of the roadway. These gates can be architecturally
designed but are not normally employed for terminal activities, due to their
operational limitations.

Portable systems

These barrier systems require no roadway excavation and can be assembled and
made operational in a relative short time. They are typically either crash-beam or
plate barriers, mounted between filled buttress boxes that limit movement if a
vehicle hits the barrier. Although, not particular to the terminal design of
Oecusse –Ambeno International Airport, they are, however, a key to the
contingent protection of the terminal's frontage.

Planters

These are another type of passive barrier which are often used and are typically
mounted using applied construction fixings. The specification regarding

154
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

landscaping in and around the planter is important, because improper planting


material could actually allow for concealment of an explosive device.

Safety

Active vehicle barriers can cause serious injury to vehicle occupants if struck
hard, and the installation of safety devices is recommended to prevent activation-
either by operator error or equipment malfunctions. Warning signs, audible
alarms, and traffic-safety paint should mark the presence of a barrier and make it
visible to oncoming traffic. Red and green traffic signals should be installed and
operated in conjunction with the barrier. The red signal should go on when the
barrier closes road access; and the green signal should illuminate only when the
barrier opens road access. In addition, pedestrian (and cycle) traffic should be
channeled away from the barrier by using pathways, landscaping, or fencing.

Other functional considerations

Frequently used perimeter entrances may require a pneumatic or hydraulic


control system designed for repeated opening and closing. These barriers can be
operated from a staffed entry-control position or from a remote location, using
CCTV and remote controls with - swipe, token or pin verification. These operating
locations should be independent and inter-changeable. Provision of a detection
process to identify an ‗under-duress‘ situation should be considered.

If the barricades are not under continuous observation, then tamper switches
should be installed to the hydraulic pump unit doors to ensure that the barrier
system is continuously controlled. These switches should be connected directly to
the central alarm monitoring station so that security staff can monitor the
barriers around the clock.

The barrier should also have an emergency operation feature, typically, capable
of raising the barrier to the up/closed position in a short time period; depending
on the barrier size (consideration should also be given to the security officer‘s
working position, the fixture position of an emergency barrier activation device
and the reaction time). Some vehicle barrier systems work in conjunction with a
lightweight plastic/aluminium ‗pre-warning‘ barrier. Backup generators or manual
override provisions are also needed to ensure continued operation of active
vehicle barriers during power failure or equipment malfunction.

Installation

Installation is one of the most important steps in the design and implementation
phases and should be well planned to avoid problems that could result in high
maintenance costs. The selected barrier company should have a strong track
record in its design and installation of vehicle barrier systems and also offer a
warranty for its products.

155
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Maintenance

Planning for barrier maintenance should start during the design phase.
Manufacturers should provide the purchaser with wiring and hydraulic diagrams,
maintenance schedules, and procedures for their systems. They should also
provide barrier maintenance support in the form of training and operation
manuals. In addition, the vendor should have an inventory of spare parts
available to maintain any of its barrier systems in operation.

Terminal External Pedestrian Area

Key planning objectives:

 Terminal external pedestrian areas should be Clean of ‗visual‘ obstruction;

 The terminal external pedestrian area is immediately in front of the terminal


structure and will be used by pedestrians only. The area allows for
congregation of people entering the terminal buildings or exiting the terminal
towards vehicle parks, taxis, and buses.

Such areas should be Clean of ‗visual‘ obstruction, such as fixed litter bins, bus
stop shelters, large advertising boarding‘s, so as to facilitate a Clean overview
and surveillance to limit the scope for concealment of an improvised explosive
device. It may also be considered that some forecourt ‗infrastructure‘ may be
designed to provide ‗blast defense‘ and may even offer further protection to the
main terminal.

Inside the Terminal

Key planning objectives:

 Mitigation and planning to provide defense, where possible, against person


borne improvised explosive devices;

 Terminal buildings are to be built with effective bomb mitigation. This is to


include standards for glazing and the recommended construction of fixtures
and fittings;

 Signage and audio/visual communications are to be effective for public


safety;

 Alarm systems are to be effective and have a correct response procedure.

Person Borne Improvised Explosive Device (PBIED) (or attack with


weapon within Terminal)

A PBIED attack can be limited, within the terminal, by various layers of


mitigation:

156
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 Allow for security agencies to be able to transit public areas with ease and to
maintain effective surveillance of such areas, for example, through CCTV and
makeover surveillance points;

 Security signage to create an anti-terrorist awareness - public observation


and reporting to aid detection;

 Moving of high density public areas behind security search combs;

 Division of high density public areas and managed flow of large numbers of
public.

Protection against PBIED, though limited, can be enhanced by the surrounding


build fabric, built to withstand blast fragmentation, particularly glazed frontages.
Airports, generally, design wide and open reception halls. These areas can
mitigate blast by the design of curved areas, blast walls and screens. Standalone
rooms, such as storage cupboards and staff access corridors, should be kept to a
minimum and be secured at all times. Raised mezzanines and balconies should be
designed to withstand blast and collateral fragmentation.

Building Structure

All public accessible building structures are built to mandated national standards,
and part of this requirement is the need to carry out a bomb blast assessment to
ensure structural and fabric robustness. This identifies any inherent weakness to
design or construction and allows for corrective measures. Balconies or
mezzanines, providing oversight of, or holding of, high density public areas, such
as check-in, may become a terrorist‘s choice of attack platform. They should be
designed to prevent unauthorized access and withstand blast and collateral
fragmentation. A formal Blast Mitigation Report (BMR) is recommended to
provide evidence of mitigation.

Glazing

The design standard for glazing must provide protection against flying glass
following an impact or explosion.

Fixtures & Fittings

Design of internal structures, such as kiosks, advertising boards and bins, should
be constructed of material able to absorb blast, but not add to fragmentation.
Retail outlets can be designed to add protection to high density areas, by their
design, construction and placement. At heightened threat levels, it is not
recommended that litter bins are used as they provide a means of concealment
for devices. Permanently fixed bins will require a method of sealing at these
times of threat.

157
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Internal Signage and Audio Visual Communications

Good signage, at an early stage, can Cleanly direct passengers to their required
areas and assist in ‗traffic‘ flow. Signage, though, is not a defense to a terrorist or
criminal intent on diverting their course. Provision of emergency service signage
is important to aid a timely response and arrival. Adequate provision of audible
communications is important, not only for ‗normal‘ operations (public
announcements), but also for emergency or evacuation situations, which may
require communication with passengers or staff in areas such as car parks.
Consideration should be given to communications being effective, with temporary
or long term loss of electrical power. Furthermore, consideration should also be
given to the use of ‗secure‘ communication devices, to mitigate against its
potential to be used/overheard by the ill-disposed.

Alarms

An Intruder Detection System (IDS) comprises of a number of individual


elements. These will include detection devices, a control panel, an alarm and
signaling equipment. IDS comprise, in the main, a magnetic field activation unit
that can be fitted to an entry/exit point or to an area. It can also be fitted to
critical equipment to alert to its use. An IDS system is capable of being used as
an alternative to, or in support of, security operators between patrolling time
points. Areas between landside and airside are a typical area to be covered by an
IDS system. When required to alert a remote guard response force, the delay
time should be appropriate to the guard response time.

Other Buildings and Access

Key planning objectives:

 Adjacent structures and Businesses should be protected by compliant bomb


blast measures and should not add to fragmentation or allow for a rapid
collapse into a high density public area.

 The needs of emergency services access and rendezvous points, in


circumstances such as in response to an incident, or during evacuations,
should be taken into account.

Emergency Services Access

The needs of emergency services access and rendezvous points, in circumstances


such as in response to an incident, or during evacuations, should be taken into
account.

Vehicle routes may become blocked and, therefore, a secondary (restricted)


route for such services must be identified and maintained. Access control
measures, such as bollards and gates, should be readily accessible, in a
controlled manner, by these services. The need for access control is important,

158
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

even for emergency services. Entry should be controlled by either CCTV, manned
security position, swipe, token, pin or transponder. At least two means of
verification should be considered for access permission. Only emergency services
should be allowed access to this route.

7.11. Structures

Description of the Buildings

The following explains the design basics used for the structural arrangement and
design of the Oecusse-Ambeno International Airport Terminal Building. The
building is a three-storey reinforced concrete structure, consisting of a moment-
resisting frame system. The building has a total length of 135m along the main X
axis and a total width of 45m along the main Y axis, plus the annex building and
link bridge, making a total implantation area of 6 200m 2. The typical inter-storey
height from level 0 to level 2 is 5m. The inter-storey height between levels 2 and
3 is 3m. In ―mezzanine‖ areas the headroom corresponds to the Cleanance height
from the level 0 until the steel roofing sheet structure, which is thereabout 11m.
The building structure has a total height of 13m, from the level 0 up to level 3.

Structural Solution and Arrangement

The Terminal is a nearly-to-regular plan building structure, with partial symmetry


around the main Y axis. Below is a description of the structural solution and also
the arrangement of the vertical members.

Foundations

 Structural foundations will consist of isolated prismatic footings,


supported by a compacted landfill, foreseen to be executed by the
contractor.

 Data resulting from ground investigation allows considering a permissible


soil pressure of 200 kPa.

Vertical members

 Apart of the vertical bearing capacity, columns and core walls were
designed as the lateral-seismic-force resisting system.

 The typical span between vertical supports along the main X axis is 9m.
Along the main Y axis, the maximum span length among axes 1-2 is
9.5m. Between axes 2-4 and 4-6; typical spans nearly 7.5m and 9m were
respectively defined. The structural plan grid is represented in the figure
below.

159
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure 1 – Structural solution and arrangement of vertical elements

The typical cross-sections of prismatic columns are 0.40x0.60m and 0.30x0.60m.


The typical cross-sections of circular columns are ϕ0.45m and ϕ0.55m.

Core walls were established at the elevator cores as well as in the central stair
core of the building. The structural thickness of the walls is 0.25m.

Horizontal members

Ground floor - level 0 consists of a solid concrete ground floor (thk. = 0.13m), to
be supported by the compacted landfill, working independently of the foundations
of the columns or shear walls.

The recommended solution to the above ground level floors (levels 1 and 2)
consists of a solid slab system (thk. = 0.25m) with drop panels on the vertical
supports (thk. = 0.45m or 0.55m) and column strips over the major span lengths
(thk. = 0.35m). At the slab edges is recommended the implementation of
prismatic edge beams with a typical cross-section of 0.30x0.80/0.90m.

Floor level 3 consists of a single slab solution (uniform thk. = 0.20m) with also
edge beams as described above.

Roof structure

Roof structure shall be in accordance with architectural design, following the


concave vaulted shape.

The structure supporting the steel roofing sheets shall be a structural steel
solution consisting of two-dimensional trusses developed over the structural grid
axes as indicated in the figure above.

160
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Both bottom and upper roofing sheets are supported by ―omega‖ steel purlins
linked to the main orthogonal steel frame grid, where adequate clear distances
are taken into account for MEP facilities installation.

Codes, Standards and Software

Main design codes and standards

 [ACI318M]ACI 318M-11 - Building Code Requirements for Structural


Concrete

 [ACI224R]ACI 224R-01 – Control of Cracking in Concrete Structures

 [ACI209R] ACI 209R-92 – Prediction of Creep, Shrinkage and


Temperature Effects in Concrete Structures

 [UBC97] Uniform Building Code, 1997 Edition, Volume 2, Structural


Engineering Design Provisions, International Conference of Building
Officials

 [SNI1726] SNI 03-1726:2012 - Specification Earthquake Design for


Building and Non Building

 [ASCE7] SEI/ASCE 7:2010 - Minimum Design Loads for Building and


Other Structures

 [AISC360] ANSI/AISC 360:2005 - Specification for Structural Steel


Building

Codes and standards for specific design requirements

For specific design requirements, all that is missing in the main codes and
standards referred above, the following codes and standards apply:

 [EC0] EN 1990 - Basis of structural design;

 [EC1]EN 1991 - Actions on structures;

 [EC2] EN 1992 - Design of concrete structures;

 [EC3] EN 1993 - Design of steel structures;

 [EC7] EN 1997 - Geotechnical design;

 [EC8] EN 1998 - Design of structures for earthquake resistance;

 [MC90] CEB-FIP Model Code 1990 - Design Code;

 [CEB208] CEB Bulletin 208:1991 – Fire design of concrete structures;

 [EN206-1] BS EN 206-1:2013 - Concrete. Specification, performance,


production and conformity;

 [EN 10002-1]:2001 - Tensile testing of metallic materials. Method of test


at ambient temperature;

 [EN 10025-2] - Structural Steel;

161
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 [EN13670-1]:2009 - Execution of concrete structures;

 [BS4449]BS 4449:2005 + A2:2009 - Steel for the reinforcement of


concrete, weld able reinforcing steel, bar, coil and decoiled product;

 [E464]LNEC E 464:2007 - Concrete. Prescriptive methodology for a


design working life of 50 and of 100 years under the environmental
exposure.

Software

For numerical analysis and structural design most of the analyses are performed
with the following software:

 SAP2000 Finite Element Analysis Software, Version 14.2.4, Computers


and Structures Inc., Berkeley CA, USA

 EXCEL / WORD MICROSOFTEXCEL 2007, MICROSOFT WORD 2007,


Microsoft Corp., Redmond WA, USA

Material Properties

The materials to be used in worksite must be certified by internationally


accredited laboratory, according to internationally accepted standards. This
document lists some of the most common standards in the world, but others may
be accepted, if they are justified by the contractor.

Concrete

Concrete f‘c =30 MPa, with a maximum relation W/C of 0.40, which is equivalent
to a C30/37 XC2/XS1 (EN designation) shall be used for all structural elements, if
not otherwise stated in the design document. The type of cement must comply
with:

 Cement type II – in general;

 Cement type V in foundations.

Concrete strength and modulus of elasticity are in accordance with [EC2], cl.
3.1.2 and 3.1.3. Cylinder concrete compressive strength fck and tensile strength
fctk,0.05 as well as the E-modulus are time-dependent material properties. Their
values increase as the time progresses up to the age of 28 days. The amounts for
times less than 28 days are analysed in accordance with [EC2], cl. 3.1.2-(6), (7)
and 3.1.3-(3), assuming normal hardening cements (class N).

 Poisson‘s ration-cracked section  =0.20 acc. to [EC2], cl. 3.1.3-(4)

 Cylinder concrete strength f´c = 30 MPa

Concrete requirements

The structural classification and values of minimum concrete cover are to be in


accordance with [UBC97], cl. 1907.7. The concrete mix design and curing shall be
in accordance with [EN206-1]. The water to be used in concrete must comply

162
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

described in [EN 1008:2002] - Mixing water for concrete — Specification for


sampling, testing and assessing the suitability of water, including water recovered
from processes in the concrete industry, as mixing water for concrete.

Reinforcing steel

Reinforcing steel shall confirm to the requirements of [EN1992], [EN10002-1]


[BS4449].

 Poisson‘s ratio  =0.30

 Secant modulus of elasticity of steel Ers =200 GPa

 Coefficient of thermal expansion α = 1.00E-05 /ºC

 Characteristic yeldstrength fy = 400 MPa

Structural steel

Structural steel shall confirm to the requirements of [EN1993-1-10] and


[EN10025-2].

 Steel grade: S275

 Poisson‘s ratio  =0.30

 Secant modulus of elasticity of steel Es =210 GPa

 Shear modulus G = 81 GPa

 Coefficient of thermal expansion α = 1.00E-05 /ºC

 Characteristic yeld strength fy = 275 MPa

 Characteristic ultimate strength fu = 275 MPa

Loads

Dead loads (DL)

The self-weight of the structure is represented by a single characteristic value


based on the nominal dimensions and mean unit mass as presented below.

 Reinforced concrete: M = 24 kN.m-3

 Structural steel: M = 78.5 kN.m-3

The remaining DL are as usual for building structures with the necessary
requirements of an airport terminal, which are summarized below:

 Brick walls: p = 2.5 kN.m-2

 Ceiling, including frame: p = 0.2 kN.m-2

 Floor coating: p = 1.2 kN.m-2

 Add. DL in technical areas: p = 1.1 kN.m-2

163
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Live loads (LL)

The building was classified in the usage category C according to the [EC1]
classification. Thus, the following characteristic live loads shall be taken into
account:

 General imposed load: q = 5.0 kN.m-2

 Stairs: q = 3.0 kN.m-2

 LL in technical areas: q = 2.0 kN.m-2

Live loads on roofs (LLr)

General imposed load: q = 1.0 kN.m-2

Add. LL by water accumulation: q = 3.5 kN.m-2

(corresponding to an average water depth of 0.35m, starting on the lower point


of the steel roofing sheet)

Wind loads (W)

Wind loads are determined in accordance with the requirements of the [ASCE7]
and the local wind speed used for buildings design according to SNI 1727:2013. The
basic wind speed is vb = 39.1 m/s for ULS design, leading to a maximum
characteristic wind-force pressure of wp = 1.05 kN/m2 assuming the total building
height referred above.
Thermal or equivalent to thermal actions (T)

Maximum and minimum uniform temperature components and creep and


shrinkage effects are in accordance with the local practice and environment
conditions.

 Concrete range of uniform temperature components: Tc,max = +15 ºC


Tc,min = -15 ºC

 Steel range of uniform temperature components: Ts,max = +35 ºC


Ts,min = -25 ºC

Creep and shrinkage effects for reinforced concrete were taken into account
according to the proposed model solution of [ACI209R].A relative humidity of the
ambient environment of 85% and rapid hardening cement is assumed.

Shrinkage Effects (ACI 209R-92)


Ultimate strain [(ε sh)u] 0.078%
Initial moist curing duration 7 days
Curing correction factor 1 Table 2.5.3
Relative humidity 85%
Humidity correction factor 0.45 Table 2.5.4

Creep Effects (ACI 209R-92)


Creep Factor (νu) 2.35 (pag. 6)
Humidity correction factor 0.7 Table 2.5.4

164
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

1.1.1 The action of shrinkage was taken as an imposed deformation of the


concrete shrinking phenomenon equivalent to a length of 3 ‰. This action
was simplified assimilated to a uniform variation of temperature of -10 ° C
for the concrete modulus of elasticity after 28 days. This measure results in
an equivalent situation to consider a 30 ° C temperature range to an
appropriate modulus of elasticity Ec,28/(1+, or Ec,28/3.
Seismic action (EQ)

The conceptual design of the building shall take into account the adequate level
of seismic protection against seismic actions. Horizontal and vertical components
of seismic action are determined in accordance with the requirements of the
[SNI1726] and [UBC97] main codes. For regular buildings, the nominal horizontal
base shear force shall be obtained from:

V = C1 I W

where:

C1 - fundamental spectral response accelaration attached to fundamental


period (T1)

I - importance factor = 1.0, acc. to [UBC97] special occupancy category

W - total seismic dead loads and factored live loads

R - coefficient representative of the inherent overstrength and global


ductility capacity of lateral-force-resisting systems = 6.5, acc. to
[UBC97] Table 16-N

Seismic zonation in Indonesia is in accordance with [SNI1726] as follows:

Figure 2 – Seismic zonation of Indonesia [SNI1726]

165
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

For the considered location of the Oecusse-Ambeno International Airport Terminal


Building, the seismic factors, to be taken into account in order to obtain the
expected linear elastic response spectrum, are as follows:

Figure 3 – Spectral parameters used for seismic investigation [SNI1726]

The resulting horizontal response spectrum from seismic investigations is as


indicated in the figure below:

HORIZONTAL RESPONSE SPECTRUM - SNI 1726-2012


8.0

7.0

6.0

5.0
SAH (m/s2 )

4.0
Hard Rock
3.0

2.0

1.0

0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
T (s)

Figure 4 – Horizontal response spectrum for seismic design of the


Oecusse-Ambeno International Airport Terminal Building

Load Factors and Combinations

For both Ultimate Limit State (ULS) and Service Limit State (SLS) design, the
load combinations and factors shall be in accordance with the main codes for the
building structural calculation and design, mainly those presented in [ACI318M],
[UBC97] and [ACI224R].

The regarded ULS load combinations are as follows:

ULS-1 = 1.4D

ULS-2 = 1.2D + 1.6L + 0.5 (Lr or R)

166
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

ULS-3 = 1.2D + 1.6 (Lr or R) + (L or 0.5 W)

ULS-4 = 1.2D + 1.0W + L+ 0.5 (Lr or R)

ULS-5 = 1.2D + 1.0E +L

ULS-6 = 0.9D + 1.0W

ULS-7 = 0.9D + 1.0E

ULS-8 = (1.2 + 0.2 SDS)D + ρQE + L

ULS-9 = (0.9 + 0.2 SDS)D + ρQE + 1.6H

ULS-10 = (1.2 + 0.2 SDS)D + ΩoQE + L

ULS-11 = (0.9 + 0.2 SDS)D + ΩoQE + 1.6H

ULS-12 = 0.75(1.4D+ 1.4T+1.7L)

ULS-13 = 1.4(D+T)

The regarded SLS load combinations are as follows:

SLS-1 = D

SLS-2 = D + L

SLS-3 = D + (Lr or R)

SLS-4 = D + 0.75L+ 0.75 (Lr or R)

SLS-5 = D + (0.6W or 0.7E)

SLS-6 = D + 0.75 (0.6W or 0.7E) + 0.75L + 0.75 (Lr or R)

SLS-7 = 0.6D + 0.6W

SLS-8 = 0.6D + 0.7E

SLS-9 = (1.0 + 0.14 SDS)D + H + F + 0.7 ρQE

SLS-10 = (1.0 + 0.10 SDS)D + H + F + 0.525 ρQE + 0.75L + 0.75 (Lr or R)

SLS-11 = (0.6 + 0.14 SDS)D + 0.7 ρQE + H

SLS-12 = (1.0 + 0.14 SDS)D + H + F + 0.7 ΩoQE

SLS-13 = (1.0 + 0.10 SDS)D + H + F + 0.525 ΩoQE + 0.75L + 0.75 (Lr or R)

SLS-14 = (0.6 + 0.14 SDS)D + 0.7 ΩoQE + H

SLS-15 = D + T + L

SLS-16 = D +T

where only the following variables shall be considered in the presented structural
design,

, is the redundancy factor = 1.3, acc to [UBC97]

167
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Ω0 - over strength factor = 2.8, acc. to [UBC97] Table 16-N

SDS - spectral design parameter

D - dead loads

L - live loads

Lr - live loads on roofs

W - wind loads

T - thermal or equivalent to thermal actions

Design Life

The design life of the Terminal building and annex structures shall be 50 years, in
accordance with [EN 1990] requirements for category 4.

Durability

For reinforced structural elements, durability is considered for design by limiting


the crack width. In addition to the requirements for design, good quality control
is required for construction, same as maintenance and inspections to guarantee
the minimum lifetime for the building structure.

Structural Analysis

For the global analysis, a three dimensional finite element model was created
using software SAP2000 as shown in the figure below.

Figure 5 – Global 3-D FEM for structural design of the Oecusse-Ambeno


International Airport Terminal Building – Rendered View

168
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

The model data are taken from relevant general layout drawings, e.g. plan views,
elevations and sections. As a general principle, 3D beam finite elements and 3D
shell finite elements (w/ 4 nodes), both with 6 DOF per node and linear elastic
characteristics for materials, are used for the design. The lengths of beam
elements shall be chosen to achieve sufficent exactness of structural stiffnesses
and in dynamic analysis also to achieve sufficient correctness for mass
distribution. Pinned support conditions of the structure at the ground level were
considered, thus obtained base solicitations are transfered directly to the
foundations. The static calculation is fulfilled by a linear equation system, as
follows:

Ku=R

where:

K – stiffness matrix

U - displacement vector

R - stress vector

Dynamic analysis is performed trough the mathematical resolution of the


following equation system, which relates the expected ground motion with the
structural response:

Mü + Cú + K u = Müg

where:

M - mass matrix

C – damping matrix

K - Stiffnessmatrix

üg - ground acceleration

ü, ú and u - acceleration, velocity and displacement of the structure, respectively

The mathematical resolution of the equation system is performed by


superposition of the Eigen modal vectors, taking into account an expected
response spectrum. Seismic ground motion is assumed to occur in three different
directions, coincident to the regarded principal axes of the structure (X, Y and Z).
Seismic analysis and corresponding stresses and displacements are determined
by complete quadratic combination (CQC) for the distinct modal responses, and
by square root of the sum. Of the squares combination (SRSS) for the three
different directional responses. The structural analysis is performed in the linear
elastic domain. Thus, the non-linear response of the structure, both for ULS and
SLS design is achieved through the application of the adequate factors and
parameters, e.g. ductility factor (R), provided in the applicable codes and
standards as mentioned above.

169
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

7.12. Commercial and Retail

Introduction

The various recommendations in this section of the design note are for review
and discussion with Owner and Stakeholders for development in the next stage of
the project.

Landside

On landside, the concept is to have a limited retail offer tailored to the meters
and greeters and other landside target groups. The only exception is food &
beverage that has a substantially larger market of meters and greeters, staff and
other non-travelers as well as passengers, e.g. waiting for check-in desks to open
(charter). The scheme has a split 20/80 for F&B and retail. The concept must
create good overview of the retail/F&B offer and create commercially good flows.

Airside

International

As soon you pass the immigration check point you will enter the commercial area.
A ‗Plaza‘ concept it will be use, locating retail outlets at the perimeter of the zone
and F&B outlets in the middle area, which enables maximum overview, as well as
ensures that passengers will be exposed to the retail facades from the F&B
seating areas in the middle. F&B outlets should ideally have maximum
transparency. Hard cores (kitchen, coolers etc.) should be carefully located to
avoid blocking sightlines to the retail facades. The scheme has a split 30/70 for
F&B and retail.

Domestic

As soon as one passes the security check point, enters the commercial area. A
‗Corridor‘ concept it will be use, locating retail outlets in one side and F&B on the
opposite side, this will ensures that passengers will be exposed to the retail
facades. The scheme has a split 20/80 for F&B and retail.

Bureau de Change

Bureau de change is not very space consuming but must be carefully located in
the flows, right after security check and/or in connection with the entrance points
of the arrival/transfer flows.

Advertising

Advertising is a major source of revenue. Identifying and planning advertising


sites and promotion spots/areas in the terminal should be done in connection

170
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

with planning the retail areas, in order to achieve the right balance between
external advertising and internal advertising for retail activities.

WIFI hot spots

WIFI hotspots should be planned in connection with planning the public seating.
WIFI hotspots should be a separate concession with separate income for the
airport.

7.13. Phasing and Implementation


Introduction
The Master Plan for the Oecusse-Ambeno International Airport, like any other
long term plan, relies on predictions of the future that may or may not transpire
as forecast. The ability to phase construction and provide flexibility in the design
to accommodate change is therefore a vital feature of any Master Plan. This
section summarises the strategy for the phasing and implementation of the
Passenger Terminal Building from opening day to end of the estimation period in
2050.

Terminal Phasing
In order to deliver the required passenger facilities, a more detailed phasing
strategy has been developed. The proposed strategy is identified in order to
ensure that the terminal and its related apron will provide sufficient capacity and
appropriate level of service during the concession period.

 Traffic growth defined by traffic forecast;


 Level of Service Cat planning years (2018 until 2050)
As for the terminal, the level of service provided by the terminal facility will be
the major factor to define when additional terminal expansion is required. Based
on the regulatory mode, the traffic growth identified in the forecast and the
simulation work undertaken on the terminal, it has been estimated that overall
the terminal will provide appropriate level of service for a period of approximately
30 years.

The apron does not necessary need to follow similar expansion timing. The
phasing needs to ensure that capacity exceeds demand at all times in order to
support the operation. The stand capacity should essentially align with terminal
expansion and, as mentioned previously, does not necessary need to match the
terminal expansion exactly.

The following figure and table illustrates the incremental expansion strategy for
the terminal building and the evolution of the terminal area provided.

Area (m²) Year 2018 Year 2050

Terminal 8,658 11,710

Table - Incremental expansion strategy

In conclusion, the terminal area phasing is largely influenced by the relationship


between two key elements: the level of service provided by the terminal building
and the provision of stands required to support airline operations. This

171
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

relationship needs to also consider the construction lead time, in order to meet
the target planning years and the growth between these targets.

The following graphic summarises the relationship of terminal expansion phasing


and Apron but also identifies indicative construction periods for each phase of
expansion and when additional facilities will come in line.

Figure – Passenger Terminal Building Expansion Diagram

Terminal Building Roof print 2018

Terminal Building Roof print 2050

172
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

8. CARGO TERMINAL BUILDING


8.1. Introduction
The Cargo Facility‘s commercial use is an asset to the International Airport of Oecusse
Ambeno, for East Timor, and in particular for the region of Oecusse. A great variety of
economic activities will be generated by the installation of this facility, encouraging other
economic activities generated by this logistical hub. The responsiveness and future
growth are taken into account in the development of this project. A strategic
operationally must be taken by the Airport stake holders

8.2. Base Data and Assumption

Planning Horizon and Forecast

The Cargo Facility has been designed to accommodate year 2018 demand, with
further expansions planned for whatever the demand required. The year 2050
was established as a feasible date to characterize a maximum Cargo Facility
expansion. The Expansion Facilities Diagram is shown below:

Figure 1 – Cargo Facility Expansion Diagram

It is assumed that the Cargo Facility will contain several operational areas that
can process dedicated air cargo (common cargo, mail, animal cargo and
perishable goods). Support facilities, such as freight forwarders and quarantine
facilities, are not located within the cargo building. The freight forwarders,
however, can be located in close proximity. It is assumed that operations will run
24 hour per day, 7 days a week, 365 days a year.

Oecusse-Ambeno International Airport Master Plan Planning and


Forecast Assumptions

The assumptions used in the cargo model to monitor the increase in facility
requirements through the concession period are outlined below:

173
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Level of Automation

The model assumes a very low level of automation, and it will operate manually
on the opening day. The automation can be introduced if required, and this
decision will be taken by the stakeholders

The area for the expansion of the cargo facilities is allocate on a linear basis, up
to a total of 1,200m2 built area - based on the 2050 forecast. Additional space
within the developed land plot can be available for further expansion beyond the
year 2050.

Support Services

There are support accommodations within the building, such as administrative


areas, customs, and healthcare and support areas, such as staff welfare
(bathrooms, break room). An initial assessment of the spatial requirements has
been made for these facilities which are detailed in the table below.

Definition Area Requirements

Reception Area 10m2

Customs Offices 8m2

Health Offices 8m2

Welfare 17m2

Table 1 - Support Services

Mail Requirements

A stand-alone depot facility is provided but locate were the Airport stakeholder
demanded and is just based on:

 Handling and storage

Process Flow

This facility can be divided into units for multiple customers, and capable of
handling different types of Cargo streams. Administration and Maintenance
Personnel accommodations will be located within the building.

174
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Below is an illustration of the material flows within the Cargo Facility:

Figure 2 – Diagram Flow Layout

The layout allows through flows for express and pre-prepared export cargo.
General cargo will be received and processed and it is either temporarily stored
or moved straight to the build and break stations. Special cargos have a
dedicated secure storage within the building. Outgoing and incoming cargo is
received on roller beds or placed in the ULD store by the Elevating Transfer
Vehicles (ETVs), for temporary storage.

Operational assumptions are made to allow a breakdown of 2018 2050


incoming and outgoing cargo to be analysed. This allows for the
approximations of process and storage areas parameters

Capacity (tpa) 50 100

Building Area 600m2 1200m2

Number of trucks docks 4 8

Number of Build/Break Stations 2 4

Support Services 65m2 130m2

Table - Planning Assumptions

175
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

8.3. Facility Summary

Cargo Building Layout

The developed layout of the cargo layout is shown below.

Figure 3 – Cargo Building Layout

It has been assumed that, given the demand level (which is low), the cargo
building will be a single storey structure with all cargo processing and storage
level on the same floor. The workstations will be controlled by the administration
areas and welfare functions. The building has a modular structure, enabling
incremental expansion. The level of automation believed to be appropriate for the
volume levels given, as to provide ETV and Roller bed ULD handling and storage,
if stakeholder so decides.

The layout provides a Clean separation between Export and Import flows. Each
Corridor area its divided in the dedicated areas, the Animal&Perishables corridor

176
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

and the Common Cargo corridor. Both have different operational requirements
procedures and must be controlled all time.

Height

It is expected that a typical module (allowing for an increased level of future


automation) could be approximately 5m in height.

Figure 4 - Cross Section

Automation and Handling

The Cargo terminal could be serviced by one Elevating Transfer Vehicles (ETV)

Bulk Store

Bulk goods waiting to be processed are held for temporary storage in the Bulk
Store, located near the Administration offices in the mezzanine. The Bulk store
can comprise 2 double aisles. Each aisle could be serviced by a high reach truck.

ULD Store

The ULD store will hold incoming cargo, as well as some outgoing goods. The
Bulk store can comprise 2 ETVs in a double aisle.

Build/Break Stations

The number of specified Build/Break stations is based on the demand and peak
hour capacity, and will be defined by the Cargo Facility stake holders.

Storage

The storage capacity is dependent of cargo characterization. It has been assumed


that the Building will hold approximately 24 hours of Export Cargo, and 24 hours
of Import Cargo. This is still well within the combined capacity of the Bulk and
ULD stores.

177
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Truck Docks and Bays

It is proposed that each phase Module would include approximately 4 truck


docks. Based on the assumptions given above, this is estimated to have enough
capacity to handle peak hour tonnage, approximately. The access to these docks
is direct. The marshalling area would be 10m deep to allow for truck parking
space and manoeuvring space. The appropriate landside requirements have been
estimated based on a maximum vehicle length of 10m and 4m wide. A canopy
created by the folding doors will be provided to cover the truck offloading area

Freight Forwarders

Freight forwarder offices may be located inside Oecusse-Ambeno International


Airport with proper land allocation area, although this decision is to be taken by
the future stakeholders. As the future Cargo demands provide these economic
and operational needs, a future development plan will be an essential key to the
airport activities.

Vehicle Types

The following provides a brief description of the vehicle types that may deliver to
the airport:

Vehicle Type Vehicle Characteristics

2 Ton,
Commercial Van
Vehicle length 6m

LGV – Light Goods Vehicle 3.5 Ton,

vehicle length 6m

7.5 Ton,
MGV – Medium Goods Vehicle
vehicle length 8m

Figure – Vehicle Type

Land Plot Requirements

Aircraft Apron Stands

The Oecusse–Ambeno International Airport Cargo Facility will initially operate


with the Apron facilities provided on the initial phase; this will require a
coordinated Airfield Operation with the Passengers Aircraft traffic flow.

It has been assumed that in the Oecusse–Ambeno International Airport


development´s ultimate phase will provide space in front of the airside Cargo
Facility for a maximum of 1 aircraft parking positions. Airside requirements
have been planned in accordance with ICAO Code E criteria;

178
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

An aircraft stand depth of 80m has been provided to accommodate code E


aircraft in the future; It is intended that this stand will be constructed as
demanded, but establishing a 2050 scenario; Adequate space should be
provided to accommodate front-end loading of dedicated air cargo aircraft;
GSE services roads of minimum 10m would be required to provide circulation
around the entire air cargo apron; Airside access roads must be provided,
which shall be equipped with the necessary security and access controls; An
illustration of the estimated airside requirements is shown below. They
Include:

 A 10m Dolly train road allowing for 2 way traffic flow;

 20m Airside marshalling allowing for dolly trains to be buffered in front of the
air cargo building;

 5m section of Roller bed;

 A 10m wide GSE header road;

 The stand is shown at 70m to accommodate code D aircraft however


sufficient depth is provided across the access taxiway and the stand to
accommodate a Code E stand;

Figure 5 - Airside Apron Illustration Block Diagram

Security

The Air cargo apron will be located in the aircraft operating area, while the
dedicated cargo and support facilities will not. As such, all access points, i.e.
roads, doors, etc. leading to this area will be equipped with controlled access
points such as card or pin code activated gates and doors. These access points
should be monitored by CCTV cameras and feeding onto a security operational
centre. The Cargo Facility will be surrounded by a standard security fence, which

179
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

is also monitored by closed circuit television. The Airside ―gap‖ between cargo
module buildings will require standard airside fencing.

Fire Access and Perimeter

Detailed design of access roads (including service and fire access) will be
provided or carried out by others, but a traffic flow scheme indication is shown
below. The layout below shows traffic flow around the complex.

Figure 6 – Fire Access Diagram

8.4. Structures
Description of the Buildings

The following explains the design basics used for the structural arrangement and
design of the Oecusse-Ambeno International Airport Cargo Facility. The building
is a single-story module steel structure consisting of moment-resisting frame
system. The building has a total length of 30m along de main X axis and a total
width of 20m along the main Y axis, making a total implantation area of 600m2.
The building structure has a total height of approximately 5m, regarded from the
level 0 up to level 1.

Structural Solution and Arrangement

The Cargo Facility is a regular plan building structure, with complete symmetry
around both main X and Y axis. Below is a description of the structural solution
and also the arrangement of the vertical members.

180
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Foundations

 Structural foundations will consist of isolated prismatic footings, supported


by a compacted landfill, foreseen to be executed by the contractor.

 Data resulting from ground investigation allows to consider a permissible


soil pressure of 200 kPa.

Vertical members

Apart of the vertical bearing capacity, columns were designed as the lateral-
seismic and wind-force resisting system.

The typical span between vertical supports along de the main X axis is 14.8m.
Along the main Y axis, the typical span is 9.8m.

The typical cross-sections of columns are HEA profiles, taking coincident with the
structural axes intersections.

Slab members

Ground floor - level 0 consists of a solid concrete ground floor (thk. = 0.13m), to
be supported by the compacted landfill, working independently of the foundations
of the columns.

Roof structure and canopy

 The roof structure shall be in accordance with the architectural design,


following the two-gabled shape.

 The recommended solution consists of a two-span main frame system


along the main X axis, with rigid connections beam-column at the
supports, and secondary beams along the main Y axis, making an
orthogonal steel frame grid, coincident with the structural grid axes.
Horizontal roof bracings are also provided.

 Profiled steel claddins shall be supported by ordinary steel Z-shaped


purlins.

Codes, Standards and Software

Main design codes and standards

 [ACI318M]ACI 318M-11 - Building Code Requirements for Structural


Concrete

181
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 [UBC97]Uniform Building Code, 1997 Edition, Volume 2, Structural


Engineering Design Provisions, International Conference of Building
Officials

 [SNI1726]SNI 03-1726:2012 - Specification Earthquake Design for


Building and Non Building

 [ASCE7]SEI/ASCE 7:2010 - Minimum Design Loads for Building and Other


Structures

 [AISC360]ANSI/AISC 360:2005 - Specification for Structural Steel


Building

Codes and standards for specific design requirements

For specific design requirements, all that is missing in the main codes and
standards referred above, the following codes and standards apply:

 [EC0] EN 1990 - Basis of structural design;

 [EC1] EN 1991 - Actions on structures;

 [EC2]EN 1992 - Design of concrete structures;

 [EC3]EN 1993 - Design of steel structures;

 [EC7]EN 1997 - Geotechnical design;

 [EC8]EN 1998 - Design of structures for earthquake resistance;

 [MC90]CEB-FIP Model Code 1990 - Design Code;

 [EN206-1]BS EN 206-1:2013 - Concrete. Specification, performance,


production and conformity;

 [EN 10002-1]:2001 - Tensile testing of metallic materials. Method of test


at ambient temperature;

 [EN 10025-2] - Structural Steel;

 [EN13670-1]:2009 - Execution of concrete structures;

 [BS4449]BS 4449:2005 + A2:2009 - Steel for the reinforcement of


concrete, weld able reinforcing steel, bar, coil and decoiled product;

 [E464]LNEC E 464:2007 - Concrete. Prescriptive methodology for a


design working life of 50 and of 100 years under the environmental
exposure.

Software

For numerical analysis and structural design most of the analyses are performed
with the following software:

182
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 SAP2000 Finite Element Analysis Software, Version 14.2.4, Computers


and Structures Inc., Berkeley CA, USA

 EXCEL / WORD MICROSOFT EXCEL 2007, MICROSOFT WORD 2007,


Microsoft Corp., Redmond WA, USA

Material Properties

The materials to be used in worksite must be certified by internationally


accredited laboratory according to internationally accepted standards. This
document lists some of the most common standards in the world, but others may
be accepted, if they are justified by the contractor.

Concrete

Concrete f‘c =30 MPa, with a maximum relation W/C of 0.40, which is equivalent
to a C30/37 XC2/XS1 (EN designation) shall be used for all structural elements, if
not otherwise stated in the design document. The type of cement to be used in
foundations must be a cement type V. Cylinder concrete compressive strength fck
and tensile strength fctk,0.05 as well as the E-modulus are time-dependent
material properties. Their values increase as the time progresses up to the age of
28 days. The amounts for times less than 28 days are analysed, assuming normal
hardening cements (class N).
 Poisson‘s ratio (un-cracked section)  =0.20, acc. to [EC2], cl. 3.1.3-(4)

 Cylinder concrete strength f´c = 30 MPa

Concrete requirements

The structural classification and values of minimum concrete cover are to be in


accordance with [UBC97], cl. 1907.7, or with EN 13670. The concrete mix design
and curing shall be in accordance with [EN206-1]. The water to be used in
concrete must comply described in [EN 1008:2002] - Mixing water for concrete —
Specification for sampling, testing and assessing the suitability of water, including
water recovered from processes in the concrete industry, as mixing water for
concrete.

Reinforcing steel

Reinforcing steel shall confirm to the requirements of [EN1992], [EN10002-1]


and [BS4449].

 Poisson‘s ratio v =0.30

 Secant modulus of elasticity of steel Ers =200 GPa

 Coefficient of thermal expansion α = 1.00E-05 /ºC

 Characteristic yeld strength fy = 400 MPa

183
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Structural steel

Structural steel shall confirm to the requirements of [EN1993-1-10] and


[EN10025-2].

 Steel grade: S275

 Poisson‘s ratio

 Secant modulus of elasticity of steel Es =210 GPa

 Shear modulus G = 81 GPa

 Coefficient of thermal expansion α = 1.00E-05 /ºC

 Characteristic yeld strength fy = 275 MPa

 Characteristic ultimate strength fu = 275 MPa

Loads

Dead loads (DL)

The self-weight of the structure is represented by a single characteristic value


based on the nominal dimensions and mean unit mass as presented below.

 Reinforced concrete: M = 24 kN.m-3

 Structural steel: M = 78.5 kN.m-3

The remaining DL are as usual for building structures with the necessary
requirements of an airport terminal, which are summarized below:

 Brick walls: p = 2.5 kN.m-2

 Ceiling including frame: p = 0.2 kN.m-2

 Floor coating: p = 1.2 kN.m-2

 Add. DL in technical areas: p = 1.1 kN.m-2

Live loads (LL)

The building was classified in the usage category C according to the [EC1]
classification. Thus, the following characteristic live loads shall be taken into
account:

 General imposed load: q = 5.0 kN.m-2

 Stairs: q = 3.0 kN.m-2

184
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 LL in technical areas: q = 2.0 kN.m-2

Live loads on roofs (LLr)

General imposed load: q = 1.0 kN.m-2

Wind loads (W)

Wind loads are determined in accordance with the requirements of the [ASCE7]
and the local wind speed used for buildings design according to SNI 1727:2013.
The basic wind speed is vb = 39.1 m/s for ULS design, leading to a maximum
characteristic wind-force pressure of wp = 0.91 kN/m2 assuming the total
building height referred above.

Thermal or equivalent to thermal actions (T)

Maximum and minimum uniform temperature components and creep and


shrinkage effects are in accordance with the local practice and environment
conditions.

Concrete range of uniform temperature components: Tc,max = +15 ºC

Tc,min = -15 ºC

Steel range of uniform temperature components: Ts,max = +35 ºC

Ts,min = -25 ºC

Creep and shrinkage effects for reinforced concrete were taken into account
according to the proposed model solution of [ACI209R].A relative humidity of the
ambient environment of 85% and rapid hardening cement is assumed.

Shrinkage Effects (ACI 209R-92)


Ultimate strain [(ε sh)u] 0.078%
Initial moist curing duration 7 days
Curing correction factor 1 Table 2.5.3
Relative humidity 85%
Humidity correction factor 0.45 Table 2.5.4

Creep Effects (ACI 209R-92)


Creep Factor (νu) 2.35 (pag. 6)
Humidity correction factor 0.7 Table 2.5.4

The action of shrinkage was taken as an imposed deformation of the concrete


shrinking phenomenon equivalent to a length of 3 ‰. This action was simplified
assimilated to a uniform variation of temperature of -10 °C for the concrete
modulus of elasticity after 28 days. This measure results in an equivalent
situation to consider a 30 °C temperature range to an appropriate modulus of

elasticity Ec,28/(1+, or Ec,28/3.

Seismic action (EQ)

The conceptual design of the building shall take into account the adequate level
of seismic protection against seismic actions.

185
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Horizontal and vertical components of seismic action are determined in


accordance with the requirements of the [SNI1726] and [UBC97] main codes. For
regular buildings, the nominal horizontal base shear force shall be obtained from:

V = C1 I W

where:

C1 - fundamental spectral response accelaration attached to fundamental period


(T1);

I - importance factor = 1.0, acc. to [UBC97] special occupancy category;

W - total seismic dead loads and factored live loads;

R - coefficient representative of the inherent overstrength and global ductility


capacity of lateral-force-resisting systems = 6.5, acc. to [UBC97] Table 16-N.

Seismic zonation in Indonesia is in accordance with [SNI1726] as follows:

Figure 1 – Seismic zonation of Indonesia [SNI1726]

For the considered location of the Oecusse-Ambeno International Airport Terminal


Building, the seismic factors, to be taken into account in order to obtain the
expected linear elastic response spectrum, are as follows:

186
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure 2 – Spectral parameters used for seismic investigation [SNI1726]

The resulting horizontal response spectrum from seismic investigations is as


indicated in the figure below:

HORIZONTAL RESPONSE SPECTRUM - SNI 1726-2012


8.0

7.0

6.0

5.0
SAH (m/s2 )

4.0
Hard Rock
3.0

2.0

1.0

0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
T (s)

Figure 5 – Horizontal response spectrum for seismic design of the


Oecusse-Ambeno International Airport Terminal Building

Load Factors and Combinations

For both Ultimate Limit State (ULS) and Service Limit State (SLS) design, the
load combinations and factors shall be in accordance with the main codes for the
building structural calculation and design, mainly those presented in [ACI318M],
[UBC97] and [ACI224R].

The regarded ULS load combinations are as follows:

ULS-1 = 1.4D

ULS-2 = 1.2D + 1.6L + 0.5 (Lr or R)

ULS-3 = 1.2D + 1.6 (Lr or R) + (L or 0.5 W)

ULS-4 = 1.2D + 1.0W + L+ 0.5 (Lr or R)

ULS-5 = 1.2D + 1.0E +L

187
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

ULS-6 = 0.9D + 1.0W

ULS-7 = 0.9D + 1.0E

ULS-8 = (1.2 + 0.2 SDS)D + ρQE + L

ULS-9 = (0.9 + 0.2 SDS)D + ρQE + 1.6H

ULS-10 = (1.2 + 0.2 SDS)D + ΩoQE + L

ULS-11 = (0.9 + 0.2 SDS)D + ΩoQE + 1.6H

ULS-12 = 0.75(1.4D+ 1.4T+1.7L)

ULS-13 = 1.4(D+T)

The regarded SLS load combinations are as follows:

SLS-1 = D

SLS-2 = D + L

SLS-3 = D + (Lr or R)

SLS-4 = D + 0.75L+ 0.75 (Lr or R)

SLS-5 = D + (0.6W or 0.7E)

SLS-6 = D + 0.75 (0.6W or 0.7E) + 0.75L + 0.75 (Lr or R)

SLS-7 = 0.6D + 0.6W

SLS-8 = 0.6D + 0.7E

SLS-9 = (1.0 + 0.14 SDS)D + H + F + 0.7 ρQE

SLS-10 = (1.0 + 0.10 SDS)D + H + F + 0.525 ρQE + 0.75L + 0.75 (Lr or R)

SLS-11 = (0.6 + 0.14 SDS)D + 0.7 ρQE + H

SLS-12 = (1.0 + 0.14 SDS)D + H + F + 0.7 ΩoQE

SLS-13 = (1.0 + 0.10 SDS)D + H + F + 0.525 ΩoQE + 0.75L + 0.75 (Lr or R)

SLS-14 = (0.6 + 0.14 SDS)D + 0.7 ΩoQE + H

SLS-15 = D + T + L

SLS-16 = D +T

where only the following variables shall be considered in the presented structural
design,

, is the redundancy factor = 1.25, acc to [UBC97]

Ω0 - over strength factor = 2.8, acc. to [UBC97] Table 16-N

SDS - spectral design parameter

D - dead loads

188
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

L - live loads

Lr - live loads on roofs

W - wind loads

T - thermal or equivalent to thermal actions

Design Life

The design life of the Terminal building and annex structures shall be 50 years in
accordance with [EN 1990] requirements for category 4.

Durability

For reinforced structural elements, durability is considered for design by limiting


the crack width. In addition to the requirements for design, good quality control
is required for construction same as maintenance and inspections. Also,
protection systems against corrosion for steel structural members shall be
provided in order to guarantee the minimum lifetime for the Cargo Facility
structure.

Structural Analysis

General

For the global analysis a three dimensional finite element model was created
using software SAP2000 as shown in the figure below.

Figure 6 – Global 3-D FEM for structural design of the Oecusse-Ambeno


International Airport Cargo Facility – Rendered View

The model data are taken from relevant general layout drawings, e.g. plan views,
elevations and sections. As a general principle, 3D beam finite elements and 3D
shell finite elements (w/ 4 nodes), both with 6 DOF per node and linear elastic
characteristics for materials, are used for the design.
The lengths of beam elements shall be chosen to achieve sufficent exactness of
structural stiffnesses and in dynamic analysis also to achieve sufficient
correctness for mass distribution. Pinned support conditions of the structure at

189
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

the ground level were considered, thus obtained base solicitations are transfered
directly to the foundations.
The static calculation is fulfilled by a linear equation system, as follows:
Ku=R

where:

K - stiffness matix

U - displacement vector

R - stress vector

Dynamic analysis is performed trought the mathematical resolution of the


following equation system, which relates the expected ground motion with the
sructural response:
Mü + Cú + Ku = Müg

where:

M - mass matrix

C - matriz de amortecimento

K - stiffness matix

üg - ground accelaration

ü, ú and u - accelaration, velocity and displacement of the structure, respectively

The mathematical resolution of the equation system is performed by


superposition of the Eigen modal vectors, taking into account an expected
response spectrum. Seismic ground motion is assumed to occur in three different
directions coincidents to the regarded principal axes of the structure (X, Y and Z).
Seismic analysis and corresponding stresses and displacements are determined
by complete quadratic combination (CQC) for the distinct modal responses and by
square root of the sum. of the squares combination (SRSS) for the three different
directional responses.

The structural analysis is performed in the linear elastic domain. Thus, the non-
linear response of the structure, both for ULS and SLS design is achieved through
the application of the adequate factors and parameters, e.g. ductility factor (R),
provided in the applicable codes and standards as mentioned above.

190
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9. STRUCTURE DESIGN CONCEPT

Structure calculations in the project will meet the criteria of strength, stability and security
and in terms of ease of implementation and effectiveness. Structure concepts to be achieved
include the following factors:

 The fulfillment system under the structure / foundation of effective and easy in
implementation based on ground investigation data and the load on the structure.
 The fulfillment of the planning system on the effective structure and is able to
accommodate the needs of architectural design and mechanical electrical or other related
services.
 The fulfillment of the entire results of the planning that has been approved and is set
based on the criteria of planning.
1. Structure Design Criteria
Basically structure design criteria will be based on rules and standard that applied below
:

a. Building Code Requirements for Structural Concrete ACI 318M-11.


b. Earthquake security procedures from Uniform Building Code (UBC, 1997 Edition,
Volume 2, Structural Engineering Design Provisions, International Conference of
Building Officials).
c. National earthquake hazards reduction program (NEHRP) recommended seismic
provisions for new buildings and other structures. FEMA P-7502009
d. Minimum Design Loads for Building and Other Structures SEI/ASCE 7-10
e. Specification For Structural Steel Building ANSI/AISC 360-10
2. Material
With regard to ease the factors, resistance to fire and effectiveness most material
structure to use reinforced concrete. Material for concrete is ready mix concrete that will
be supplied by the concrete supplier.

Following is the quality of material that are used in the structure:

1. Reinforced concrete Fcube 350kg/cm 2.

2. Reinforce threaded steel (deformed rebar) for the concrete fy: 400 MPa

3. Steel frame

Steel quality for roof frame, Yield strength 250 MPa and Tensile Strength 410 MPa

4. Embankment Material

For building leveling, the material that used for the embankment is sandy gravel
unsieved with soaked CBR ≥ 45% and density ≥ 95%.

5. Loads
Planned in accordance with applicable regulations in Indonesia by in consideration of the
other reference if it‘s necessary.

191
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Load type :

1. Dead Load (DL)


Concrete : 2.200 kg/m3
Reinforced concrete : 2.400 kg/m3
Steel : 7.850 kg/m3
Brick wall :250 kg/m2
Lightweight brick : 125 kg/m2
Ceiling : 11 kg/m2
Ceiling Gallows : 7 kg/m2
Roof including frame : 50 kg/m2
Tile (per cm thickness) : 24 kg/m2
2. Live Load (LL)
Live load on the building floor including the equipment and the partition weighing
less than 100 kg/m2. Special equipment load will be determined its own

Live Load on The Building Floor:


Office : 250 kg/m2
Meeting Room : 500 kg/m2
Hall : 500 kg/m2
Mechanical Electrical Room : 500 kg/m2
Stairs : 300 kg/m2
Parking : 400 kg/m2
Roof and Canopy : 100 kg/m2
3. Earthquake Load (EQ)
The following zoning earthquake in Indonesia in accordance with Earthquake Security
Procedures for Building Design.

192
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Rock Hard Soil Medium Soft Soil


s

For design, we use:

For regular buildings, the earthquake load nominal, Earthquake Plan shown as
nominal static equivalent earthquake load (Fi), which captures the center of mass of
the floors level. Base Shear Static Load Nominal Equivalent (V)

V = C1.I.Wt
R
With:

Wt = Total weight of the building including live load reduce.


C1 = Response factor earthquake. Earthquake Spectral Response Plan
is attached at the time of fundamental natural period (T1).
T1 = Natural Period
= 0.06 H¾
H = Height of the building from the level of the lateral clamping
I = Virtue Factor
R = Earthquake Reduction Factor

Nominal load static equivalent earthquake (Fi)

Fi =Wi zi V
∑ Wi zi
With:

V = Nominal Base Shear.


Fi = Earthquake load nominal on the floor - i.
Wi = Weight Floor Level– i.
zi = High level floor – I of the level of lateral clamping.

193
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

4. Wind Load (WL)


Wind load used in this design is 77 kg/m2, which is the minimum wind load in
SEI/ASCE 7-10 (See Attachment)

5. Load Combination

6. Structure Analysis Concepts


Structural analysis using SAP2000 program version 17 and SANSPRO version 5.00
with the analysis of 3D modeled as frame-3 Dimensions. Geometric defined
structure of the line and column spans relationship that produces frames-3
Dimensions. Seismic force calculations performed by the dynamic 3-D analysis
(Model Analysis) by applying elastic response spectrum.

7. Foundation analysis

Foundation analysis calculated by looking at the total axial forces that occurs at any
point of the restrain. Where the total axial force at each point must be hold by the
foundation. These are the foundation type of all building in the landside area.

8
No. Type Of Building Roof Upper Structure Sub Structure
.
1
1 ATC Building Steel Frame Concrete Frame Pile Foundation

2 Meteorology Building Concrete Frame Concrete Frame Foot Plate


A
3
T MPH Building Concrete Frame Steel Frame Foot Plate
C
4 RFFS Building Steel Frame Steel Frame Foot Plate

5
B GSE Building Steel Frame Steel Frame Foot Plate

U
6 Quarantine Building Steel Frame Steel Frame Foot Plate
I

194
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.1 ATC Tower

Model For ATC Crown

9.1.1 Load Assign

Load assign are the load that are assigned to the structure so the
structure can handle the load safely. There are 6 different types of loads
that are assigned to the structure of this building. These are: Dead, SIDL,
Live, Wind, Quake and Live roof. The figure below shows load that are
assigned to the building structure.

o Live load on the roof 100 kg/cm2

o SIDL on the roof 198 kg/cm2

o SIDL on tie beam 10.98 kg/cm2

9.1.2 Element Forces

Element force is a force that exists inside the element (beam or column).
It consists of 3 forces: Axial, Shear and Moment. The design must handle

195
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

all these three kind of force. The figure below shows how much force that
works inside the element.

Axial Force

Major Moment

196
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Minor Moment

Major Shear

197
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Minor Shear

Torsion

9.1.3 Deflection

Deflection is the degree to which a structural element is displaced under a load. It


may refer to an angle or a distance. The deflection distance of a member under a
load is directly related to the slope of the deflected shape of the member under
that load and can be calculated by integrating the function that mathematically
describes the slope of the member under that load. Maximum deflection for ATC
tower is 3.75 mm.

198
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Deflection Diagram For ATC

9.1.4 Mode Shape

Mode shape is a specific vibration pattern that runs by a mechanical


system at a certain frequency. Forms mode different shape, it is
associated with the frequency of different objects. In the process of
designing a structural system, it is important for planners to determine
the mode shape of the structure of the system to avoid the dominant
variety in the structure. In this case, the mode shapes that happen must
be translation at mode shape 1 and 2. In the mode shape 3, it should be
rotation. Mode shape associated with natural frequencies. Mode shape for
ATC building is shown with the figure below.

Mode 1, 2 and 3 For ATC Tower

199
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.1.5 Stress Ratio

The analysis result is shown by the ratio between the forces and capacity.
If ratio is more than 1, then the ratio color became red. If the color still
blue, green or maybe yellow, it means beam and column capacity has not
been exceed the ultimate forces and moment.

Result For ATC Building

9.1.6 Foundation Design

For ATC building, we use spun foundation. These are the specification for
the spun pile foundation:

 Diameter: 45cm
 Depth: 31m
 Capacity:90 Ton
 Concrete: Fcube 600 kg/cm2

200
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.1.6.1 Support Reaction

SUPPORT REACTIONS

Flr No. Comb Fx Fy Fz Mx My Mz


0 11 MAX 72377 1.06E+06 1.16E+05 1.09E+07 34998 8.33E+06
MIN -23915 -2.06E+05 -10607 -2.65E+06 -14508 -5.00E+06
0 12 MAX 32178 1.06E+06 1.17E+05 1.09E+07 32947 1.43E+06
MIN -52465 -1.99E+05 -9019.8 -2.64E+06 -17126 -9.60E+06
0 15 MAX 596.92 7.62E+05 85258 1.42E+07 51396 5.57E+05
MIN -20.229 -84352 -37128 9.99E+05 -554.75 -2466.2
0 22 MAX 597.46 7.69E+05 85340 1.44E+07 50777 5.58E+05
MIN -11.645 -89055 -37498 1.01E+06 -792.93 -519.17
0 28 MAX 546.52 4.91E+05 1.06E+05 3.72E+05 33268 4.93E+05
MIN -55.963 -41459 -240.59 -1.90E+06 -447.46 980.49
0 29 MAX 635.66 4.92E+05 1.07E+05 3.38E+05 31832 4.85E+05
MIN 1.9882 -38517 1000.6 -1.84E+06 -1494.3 -4372.2
0 30 MAX 1.00E+05 8.05E+05 39035 6.15E+06 20165 6.76E+06
MIN -16588 -1.39E+05 -34597 -7.63E+05 -16956 -3.63E+06
0 32 MAX 55468 8.11E+05 37958 6.25E+06 19653 -8.20E+05
MIN -48542 -1.35E+05 -34508 -6.37E+05 -17806 -8.99E+06

Support Reaction ATC Building

8.1.6.2 Soil Parameter from Soil Investigation

201
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.1.7 Summary

Upper Structure:

 Column: Concrete 600x400

 Shear Wall: t=40cm

 Primary Beam: Concrete 600x400

 Secondary Beam: Concrete 400x300

 Concrete Deck: t=15cm

Foundation: Spun Pile Foundation D-45 L=31 m

Depth plan for spun pile is 31 m. but it can variety depends on:

- Final set (2,5-5 cm for 10 last hammer drop) the final set value
calculated using Hailey Dinamic formula.

- Hard soil profile according to soil investigation.

9.2. METEOROLOGY BUILDING

9.2.1 Load Assign

Load assign are the load that are assigned to the structure so the
structure can handle the load safely. There are 6 different types of loads
that are assigned to the structure of this building. These are: Dead, SIDL,
Live, Wind, Quake and Live roof. The figure below shows load that are
assigned to the building structure.

202
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

o Live load on the roof 100 kg/cm2

o SIDL on the roof 198 kg/cm2

o SIDL on tie beam 10.98 kg/cm2

Earthquake load

9.2.2 Element Forces

Element force is a force that exists inside the element (beam or column).
It consists of 3 forces: Axial, Shear and Moment. The design must handle
all these three kind of force. The figure below shows how much force that
works inside the element.

Axial Force

Major Moment

203
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Minor Moment

Major Shear

Minor Shear

Torsion

204
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.2.3 Deflection

Deflection is the degree to which a structural element is displaced under a load. It


may refer to an angle or a distance. The deflection distance of a member under a
load is directly related to the slope of the deflected shape of the member under
that load and can be calculated by integrating the function that mathematically
describes the slope of the member under that load.

Structure Deflection

9.2.4 Mode Shape

Mode shape is a specific vibration pattern that runs by a mechanical


system at a certain frequency. Forms mode different shape, it is
associated with the frequency of different objects. In the process of
designing a structural system, it is important for planners to determine
the mode shape of the structure of the system to avoid the dominant
variety in the structure. In this case, the mode shapes that happen must
be translation at mode shape 1 and 2. In the mode shape 3, it should be
rotation. Mode shape associated with natural frequencies. Mode shape for
GSE building is shown with the figure below.

Mode 1

205
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Mode 2

Mode 3

9.2.5 Stress Ratio

The analysis result is shown by the ratio between the forces and capacity.
If ratio is more than 1, then the ratio color became red. If the color still
blue, green or maybe yellow, it means beam and column capacity has not
been exceed the ultimate forces and moment.

206
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.2.6 Foundation Design

Maximum axial force for one restrain is 420 kN. So the foundation for
GSE building is 1.8m X 1.8m X 0,4 m. (The detailed calculation shown in
the appendix.)

207
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.2.6.1 Support Reaction

SUPPORT REACTIONS

Flr No. Comb Fx Fy Fz Mx My Mz


0 1 MAX 6510.3 21996 5.8614 0 0 0
MIN 114.87 3142.8 -4889.6 0 0 0
0 3 MAX 12290 25154 191.41 0 0 0
MIN -2660.5 4224.2 -3938.6 0 0 0
0 5 MAX 11871 23373 -70.474 0 0 0
MIN -2539.7 4129.7 -3455.7 0 0 0
0 7 MAX 12347 24343 -160.5 0 0 0
MIN -2598.8 4235.3 -2992 0 0 0
0 9 MAX 3285.1 22681 -206.78 0 0 0
MIN -2382.7 3174.4 -3070.3 0 0 0
0 18 MAX 5459.9 34106 2848.8 0 0 0
MIN 139.76 4444.1 -8699.1 0 0 0
0 20 MAX 11708 42054 2249.9 0 0 0
MIN -1425.6 5857 -7405.4 0 0 0
0 22 MAX 11128 40643 1710.5 0 0 0
MIN -1443.5 5718.4 -6278.6 0 0 0
0 24 MAX 11523 41703 1271.4 0 0 0
MIN -1508.6 5818.9 -5219.8 0 0 0
0 26 MAX 3498.4 30020 2923.3 0 0 0
MIN -1469.8 4094.5 -4271.6 0 0 0
0 38 MAX 5128.6 31742 4245.7 0 0 0
MIN 145.17 4439.5 -7643.4 0 0 0
0 40 MAX 10977 42034 3555.1 0 0 0
MIN -1504.8 5855 -6384.5 0 0 0
0 42 MAX 10365 40665 2816.9 0 0 0
MIN -1535.6 5713.6 -4845.3 0 0 0
0 44 MAX 10406 40699 2447.5 0 0 0
MIN -1489.3 5704.8 -3982.8 0 0 0
0 46 MAX 10775 34351 2357.9 0 0 0
MIN -1442.6 4980.7 -7904.4 0 0 0
0 48 MAX 2869.9 33789 3648.3 0 0 0
MIN -1690.8 2874.1 -7292.9 0 0 0
0 60 MAX 5538.6 23055 3203 0 0 0
MIN 125.09 3139.4 -2404.6 0 0 0
0 62 MAX 10489 24415 2419.3 0 0 0
MIN -2850.6 4238.3 -2188.4 0 0 0
0 64 MAX 7852.9 30381 4431.1 0 0 0
MIN -2275.2 5188.1 -6806.7 0 0 0
0 66 MAX 8179.5 29695 3754.3 0 0 0
MIN -2040 5199.8 -5070.4 0 0 0
0 68 MAX 10516 24868 2001.5 0 0 0
MIN -2783.1 4297.5 -768.91 0 0 0
0 70 MAX 2321.4 23405 2969.2 0 0 0
MIN -2366.9 3186.7 -207.76 0 0 0
0 71 MAX 2677.5 17053 912.89 0 0 0
MIN -1343.7 -6187.2 -3409.3 0 0 0
0 72 MAX 3095.8 18063 692.85 0 0 0
MIN -1062.7 -8897.2 -2738.4 0 0 0
0 79 MAX 6690.6 29500 3905.4 0 0 0
MIN 217.85 3575 -7516.9 0 0 0
0 80 MAX 2785.6 17714 2759.2 0 0 0
MIN -2254.6 -5594.1 -4409.4 0 0 0

208
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.2.6.2 Soil Parameter From Soil Investigation

9.2.7 Summary

Upper Structure:

 Column: Concrete 400x400

 Primary Beam: Concrete 400x200

 Secondary Beam: Concrete 300x150

 Tie Beam: Concrete 400x300

 Concrete Deck: t=13cm

Foundation: Foot Plate Foundation 2x2x0.4 m

Tie Beam Layout

209
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Beam Layout

9.2.8 Connection Between ATC and Meteorology Building

ATC and Meteorology Building are modeled separately. But in the project, the
building will be integrated using dilatation system. The dilatation system that will
be use for this building is beam dilatation. So the beam from Meteorology building
will be cantilever type beam and that beam will be connect to the ATC building
beam with a distance about 10cm. (See the drawing for detailed information)

These are the conditions that must be fulfil if we want to use beam dilatation
system:

 The cantilever beam spans up to 1/3 of the span beam.

 At the location of dilatation landscape changed to 2/3 column spans the other
columns.

 The distance between a cantilever beam with another beam should be about 10
cm of the existing building.

For the foundation, the ATC Building use bored pile meanwhile the Meteorology
building use foot plate foundation. So in some foundation spot, the pile cap for the
ATC Building will be placed below the foot plate foundation for Meteorology
building. But between the pile cap and the footplate foundation will be backfilled
with sandy gravel embankment with 8% CBR value.

210
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.3 MAIN POWER HOUSE BUILDING

9.3.1 Load Assign

Load assign are the load that are assigned to the structure so the
structure can handle the load safely. There are 6 different types of loads
that are assigned to the structure of this building. These are: Dead, SIDL,
Live, Wind, Quake and Live roof. The figure below shows load that are
assigned to the building structure.

Live Load 100 kg/m2

211
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Live Roof Load 22 kg/m2

Super Imposed Dead Load 20 kg/m2

Wind Load 77 kg/m2

212
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Quake Load Using Auto Lateral Seismic IBC

9.3.2 Element Forces

Element force is a force that exists inside the element (beam or column).
It consists of 3 forces: Axial, Shear and Moment. The design must handle
all these three kind of force. The figure below shows how much force that
works inside the element.

Axial Force

Major Shear

213
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Minor Shear

Major Moment

Minor Moment

214
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Torsion

9.3.3 Deflection

Deflection is the degree to which a structural element is displaced under


a load. It may refer to an angle or a distance. The deflection distance of a
member under a load is directly related to the slope of the deflected
shape of the member under that load and can be calculated by
integrating the function that mathematically describes the slope of the
member under that load.

9.3.4 Mode Shape

Mode shape is a specific vibration pattern that runs by a mechanical


system at a certain frequency. Forms mode different shape, it is
associated with the frequency of different objects. In the process of
designing a structural system, it is important for planners to determine
the mode shape of the structure of the system to avoid the dominant
variety in the structure. In this case, the mode shapes that happen must
be translation at mode shape 1 and 2. In the mode shape 3, it should be
rotation. Mode shape associated with natural frequencies. GSE building
have 0.8769 second natural period. It means it has 1.14028 Hz natural
frequencies. Mode shape for GSE building is shown with the figure below.

215
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Mode Shape 1

Mode Shape 2

Mode Shape 3

216
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.3.5 Stress Ratio

The analysis result is shown by the ratio between the forces and capacity.
If ratio is more than 1, then the ratio color became red. If the color still
blue, green or maybe yellow, it means beam and column capacity has not
been exceed the ultimate forces and moment.

Analysis Result

9.3.6 Foundation Design

Maximum axial force for one restrain is 340 kN. So the foundation for
MPS building is 1,75m X 1,75m X 0,4 m. (The detailed calculation shown
in the appendix.)

Foundation Design For MPS

217
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.3.6.1 Support Reaction

SUPPORT REACTIONS

Flr No. Comb Fx Fy Fz


0 1 MAX 1777.3 13924 1110.7
MIN -270.87 5171.5 -2011.8
0 2 MAX 1888 16174 998.54
MIN -1905.7 9968.6 -2064.8
0 3 MAX 1882.8 15283 889.24
MIN -1835 11917 -1948.1
0 4 MAX 1881.4 18147 782.56
MIN -1840.3 11553 -1750.3
0 5 MAX 1946.2 17157 682.92
MIN -1856.1 13011 -1660.7
0 6 MAX 290.63 12621 592.3
MIN -1762.5 6972.6 -1565.2
0 7 MAX 1766.7 18345 2868.2
MIN -230.47 10691 -2717.4
0 8 MAX 1888.7 34032 1985.8
MIN -1882.5 28409 -1108.3
0 9 MAX 1845 28711 1873.4
MIN -1864.3 27694 -988.98
0 10 MAX 1844.9 24445 2284.9
MIN -1833.5 20966 -2240.8
0 11 MAX 1914.7 23335 2125.1
MIN -1859.1 21513 -2111.5
0 12 MAX 270.18 17221 1962.3
MIN -1766.9 11191 -1954
0 13 MAX 56.126 17683 2336.8
MIN -0.02786 14379 -2800.7
0 14 MAX 1767.5 26722 1829.6
MIN -345.02 22934 -2350.4
0 15 MAX 1925.9 24616 1676.1
MIN -1962.6 23103 -2209.1
0 16 MAX 275.01 18482 1505.1
MIN -1780.2 12316 -2087
0 17 MAX 2035.9 19963 2040.4
MIN 272.45 13861 -520.34
0 18 MAX 1897.8 23213 1785.8
MIN -1951.5 18080 -283.26
0 19 MAX 1989.2 18844 1729
MIN -1966.6 15373 -208.45
0 20 MAX 320.72 18399 1631.1
MIN -1814.2 10416 -152.23
0 21 MAX 1366 27631 23.412
MIN -2722.9 25075 -6.471
0 22 MAX 2420.1 22177 24.438
MIN -1885.8 17989 -4.1561

Support Reaction in Kg/cm2

9.3.6.2 Soil Parameter From Soil Investigation

Capacity Ratio From Soil Investigation

9.3.7 Summary

Upper Structure:

 Column: H-Beam 400x400x13x21

 Primary Beam: WF 400x200x8x13

 Secondary Beam: H-Beam 175x175x7.5x11

 Cantilever Beam: WF 250x125x6x9

218
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 Pedestal: Concrete 550x550

 Tie Beam: Concrete 400x600

 Concrete Deck: t=13cm

Foundation:

 Foot Plate Foundation 1,75x1,75x0,4 m

Foundation Plan For MPS Building

Roof Plan For MPS Building

219
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.4 RESCUE AND FIRE FIGHTING SERVICES BUILDING

9.4.1 Load Assign

Load assign are the load that are assigned to the structure so the
structure can handle the load safely. There are 6 different types of loads
that are assigned to the structure of this building. These are: Dead, SIDL,
Live, Wind, Quake and Live roof. The figure below shows load that are
assigned to the building structure.

Live Load 100 kg/m2

220
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Live Roof Load 22 kg/m2

Super Imposed Dead Load 20 kg/m2

221
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Wind Load 77 kg/m2

Quake Load Using Auto Lateral Seismic IBC

9.4.2 Element Forces

Element force is a force that exists inside the element (beam or column).
It consists of 3 forces: Axial, Shear and Moment. The design must handle
all these three kind of force. The figure below shows how much force that
works inside the element.

222
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Axial Force

Major Shear

223
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Minor Shear

Major Moment

Minor Moment

224
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Torsion

9.4.3 Deflection

Deflection is the degree to which a structural element is displaced under


a load. It may refer to an angle or a distance. The deflection distance of a
member under a load is directly related to the slope of the deflected
shape of the member under that load and can be calculated by
integrating the function that mathematically describes the slope of the
member under that load. The maximum deflection is 37,7 mm.

9.4.4 Mode Shape

Mode shape is a specific vibration pattern that runs by a mechanical


system at a certain frequency. Forms mode different shape, it is
associated with the frequency of different objects. In the process of
designing a structural system, it is important for planners to determine
the mode shape of the structure of the system to avoid the dominant
variety in the structure. In this case, the mode shapes that happen must
be translation at mode shape 1 and 2. In the mode shape 3, it should be
rotation. Mode shape associated with natural frequencies. GSE building
have 1,452 second natural period. It means it has 0.68832 Hz natural
frequencies. Mode shape for GSE building is shown with the figure below.

225
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Mode Shape 1

Mode Shape 2

226
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Mode Shape 3

9.4.5 Stress Ratio

The analysis result is shown by the ratio between the forces and capacity.
If ratio is more than 1, then the ratio color became red. If the color still
blue, green or maybe yellow, it means beam and column capacity has not
been exceed the ultimate forces and moment.

Stress Ratio

227
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.4.6 Foundation Design

Maximum axial force for one restrain is 190 kN. So the foundation for
RFFS building is 1,5m X 1,5m X 0,4 m. (The detailed calculation shown in
the appendix.)

Foundation Design For RFFS

9.4.6.1 Support Reaction

SUPPORT REACTIONS

Flr No. Comb Fx Fy Fz Mx My Mz


0 1 MAX -1132.9 7630 -913.7 0 0 0
MIN -1279 6883.6 -1051.2 0 0 0
0 2 MAX -2047.3 10488 427.95 0 0 0
MIN -2442.9 9877.7 303.13 0 0 0
0 3 MAX -3427.6 8450.8 -888.17 0 0 0
MIN -3963.5 7928.5 -1009.1 0 0 0
0 4 MAX 7185.3 18846 914.67 0 0 0
MIN 6420.2 17315 826.27 0 0 0
0 5 MAX 492.7 13017 112.71 0 0 0
MIN 319.16 12662 -112.59 0 0 0
0 7 MAX -66.47 16541 -273.24 0 0 0
MIN -154.32 16061 -557.21 0 0 0
0 9 MAX 415.53 8576.2 1032.1 0 0 0
MIN 277.65 7742.4 895.9 0 0 0
0 10 MAX -106.96 9858.5 -202.78 0 0 0
MIN -298.25 9322.4 -333.38 0 0 0
0 11 MAX -21.334 11363 998.12 0 0 0
MIN -174.11 10562 880.73 0 0 0
0 12 MAX -50.966 9716.8 -416.8 0 0 0
MIN -243.89 9190 -554.04 0 0 0
0 14 MAX 277.89 18849 3161.8 0 0 0
MIN 49.123 17873 2682.4 0 0 0
0 15 MAX -73.772 5980.6 -2862.8 0 0 0
MIN -199.83 5445.5 -3270.1 0 0 0

228
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.4.6.2 Soil Parameter From Soil Investigation

9.4.7 Summary

Upper Structure:

o Column: H 300x300x10x15

o Primary Beam: WF 300x150x13x15

o Secondary Beam: H-Beam 150x125x8.5x14

o Pedestal: Concrete 500x500

o Tie Beam: Concrete 300x500

Foundation: Foot Plate Foundation 1,5x1,5x0,4 m

Foundation and Roof Plan For RFFS Building

229
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.5 GROUND SERVICE EQUIPMENT BUILDING

9.5.1 Load Assign

Load assign are the load that are assigned to the structure so the
structure can handle the load safely. There are 6 different types of loads
that are assigned to the structure of this building. These are: Dead, SIDL,
Live, Wind, Quake and Live roof. The figure below shows load that are
assigned to the building structure.

Live Load And Live Roof Load 122 kg/m2

230
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Super Imposed Dead Load 20 kg/m2

Wind Load 77 kg/m2

Quake Load Using Auto Lateral Seismic IBC

9.5.2 Element Forces

Element force is a force that exists inside the element (beam or column). It
consists of 3 forces: Axial, Shear and Moment. The design must handle all these
three kind of force. The figure below shows how much force that works inside the
element.

231
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Axial Force

Major Shear

Minor Shear

232
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Major Moment

Minor Moment

Torsion

9.5.3 Deflection

Deflection is the degree to which a structural element is displaced under


a load. It may refer to an angle or a distance. The deflection distance of a
member under a load is directly related to the slope of the deflected
shape of the member under that load and can be calculated by

233
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

integrating the function that mathematically describes the slope of the


member under that load. The maximum deflection for GSE building is
14,687mm.

9.5.4 Mode Shape

Mode shape is a specific vibration pattern that runs by a mechanical


system at a certain frequency. Forms mode different shape, it is
associated with the frequency of different objects. In the process of
designing a structural system, it is important for planners to determine
the mode shape of the structure of the system to avoid the dominant
variety in the structure. In this case, the mode shapes that happen must
be translation at mode shape 1 and 2. In the mode shape 3, it should be
rotation. Mode shape associated with natural frequencies. GSE building
have 1,452 second natural period. It means it has 0.68832 Hz natural
frequencies. Mode shape for GSE building is shown with the figure below.

Mode 1

Mode 2

234
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Mode 3

9.5.5 Stress Ratio

The analysis result is shown by the ratio between the forces and capacity.
If ratio is more than 1, then the ratio color became red. If the color still
blue, green or maybe yellow, it means beam and column capacity has not
been exceed the ultimate forces and moment.

Analysis Result For GSE Building

9.5.6 Foundation Design

Maximum axial force for one restrain is 210 kN. So the foundation for
GSE building is 1,5m X 1,5m X 0,4 m. (The detailed calculation shown in
the appendix.)

Foundation Design For GSE

235
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.5.6.1 Support Reaction

SUPPORT REACTIONS

Flr No. Comb Fx Fy Fz Mx My Mz


0 1 MAX 727.54 11678 -1134.7 0 0 0
MIN -935 6058.8 -3359.3 0 0 0
0 2 MAX 1942.7 11276 1271.2 0 0 0
MIN -1890.3 9645.1 -527 0 0 0
0 3 MAX 1487.3 13571 2274.7 0 0 0
MIN -1487 8749.5 -928 0 0 0
0 4 MAX 1644.9 12834 1174.2 0 0 0
MIN -1696.5 8087.5 -430.11 0 0 0
0 5 MAX 670.71 10166 -1273 0 0 0
MIN -463.97 7592.1 -3209 0 0 0
0 6 MAX 2650.9 20545 3495.2 0 0 0
MIN -1380.4 11369 -2793.7 0 0 0
0 10 MAX -42.869 19267 3512.8 0 0 0
MIN -1228.5 12646 -2811.8 0 0 0
0 11 MAX 2411.8 19412 4089.4 0 0 0
MIN -1332 9508.8 -3213.5 0 0 0
0 15 MAX 23.675 18383 4064.2 0 0 0
MIN -1093 10532 -3180.3 0 0 0
0 16 MAX 851.81 11389 2676.7 0 0 0
MIN -1176.7 4395 299.88 0 0 0
0 17 MAX 2276.4 11503 729.93 0 0 0
MIN -2231.1 9378.9 -1544.8 0 0 0
0 18 MAX 1739.9 14600 1526.9 0 0 0
MIN -1750.3 7929.2 -2890.4 0 0 0
0 19 MAX 1884.7 13421 552.79 0 0 0
MIN -1978.6 7448.2 -1322.7 0 0 0
0 20 MAX 934.48 9754.6 2520.6 0 0 0
MIN -600.42 6054.7 429.93 0 0 0

9.5.6.2 Soil Parameter From Soil Investigation

9.5.7 Summary

Upper Structure:

o Column: H-Beam 400x400x13x21

o Primary Beam: WF 300x150x8x13

o Secondary Beam: H-Beam 150x125x8.5x14

o Pedestal: Concrete 500x500

236
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

o Tie Beam: Concrete 300x400

Foundation: Foot Plate Foundation 1,5x1,5x0,4 m

GSE Foundation Plan

GSE Roof Plan

237
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.6 QUARANTINE BUILDING

9.6.1 Load Assign

Load assign are the load that are assigned to the structure so the
structure can handle the load safely. There are 6 different types of loads
that are assigned to the structure of this building. These are: Dead, SIDL,
Live, Wind, Quake and Live roof. The figure below shows load that are
assigned to the building structure.

Live Load And Live Roof Load 121 kg/m2

238
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Super Imposed Dead Load 20 kg/m2

Wind Load 77 kg/m2

Quake Load Using Auto Lateral Seismic IBC

9.6.2 Element Forces

Element force is a force that exists inside the element (beam or column). It
consists of 3 forces: Axial, Shear and Moment. The design must handle all these
three kind of force. The figure below shows how much force that works inside the
element.

239
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Axial Force

Major Shear

Minor Shear

240
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Major Moment

Minor Moment

Torsion

9.6.3 Deflection

Deflection is the degree to which a structural element is displaced under


a load. It may refer to an angle or a distance. The deflection distance of a
member under a load is directly related to the slope of the deflected
shape of the member under that load and can be calculated by

241
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

integrating the function that mathematically describes the slope of the


member under that load.

9.6.4 Mode Shape

Mode shape is a specific vibration pattern that runs by a mechanical


system at a certain frequency. Forms mode different shape, it is
associated with the frequency of different objects. In the process of
designing a structural system, it is important for planners to determine
the mode shape of the structure of the system to avoid the dominant
variety in the structure. In this case, the mode shapes that happen must
be translation at mode shape 1 and 2. In the mode shape 3, it should be
rotation. Mode shape associated with natural frequencies. Quarantine
building have 1,78549 second natural period. It means it has 0.56007 Hz
natural frequencies. Mode shape for Quarantine building is shown with
the figure below.

Mode 1

Mode 2

242
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Mode 3

9.6.5 Stress Ratio

The analysis result is shown by the ratio between the forces and capacity.
If ratio is more than 1, then the ratio color became red. If the color still
blue, green or maybe yellow, it means beam and column capacity has not
been exceed the ultimate forces and moment.

Analysis Result For Quarantine Building

9.6.6 Foundation Design

Maximum axial force for one restrain is 210 kN. So the foundation for
Quarantine building is 1,5m X 1,5m X 0,4 m. (The detailed calculation
shown in the appendix.)

243
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Foundation Design For Quarantine Building

8.6.6.1 Support Reaction

TABLE: Joint Reactions


Joint OutputCase CaseType StepType F1 F2 F3 M1 M2 M3
Text Text Text Text KN KN KN KN-m KN-m KN-m
67 ENVELOPE Combination Max 67.327 -0.784 182.799 0 0 0
67 ENVELOPE Combination Min -0.881 -39.005 17.981 0 0 0
68 ENVELOPE Combination Max 3.316 0.022 289.364 0 0 0
68 ENVELOPE Combination Min -9.796 -38.994 29.901 0 0 0
69 ENVELOPE Combination Max 5.134 4.66 292.768 0 0 0
69 ENVELOPE Combination Min -14.238 -39.096 37.905 0 0 0
70 ENVELOPE Combination Max -0.13 -0.689 166.174 0 0 0
70 ENVELOPE Combination Min -48.46 -39.006 18.695 0 0 0
98 ENVELOPE Combination Max 66.085 1.938 268.08 0 0 0
98 ENVELOPE Combination Min -2.556 -19.857 22.95 0 0 0
99 ENVELOPE Combination Max 67.263 55.595 195.786 0 0 0
99 ENVELOPE Combination Min -1.146 0.326 18.525 0 0 0
100 ENVELOPE Combination Max 3.463 55.608 303.892 0 0 0
100 ENVELOPE Combination Min -10.424 -1.139 29.699 0 0 0
101 ENVELOPE Combination Max 5.476 55.603 311.534 0 0 0
101 ENVELOPE Combination Min -14.546 -10.421 30.51 0 0 0
102 ENVELOPE Combination Max 0.186 55.597 179.033 0 0 0
102 ENVELOPE Combination Min -48.506 0.233 15.961 0 0 0
107 ENVELOPE Combination Max 2.84 3.661 382.548 0 0 0
107 ENVELOPE Combination Min -14.009 -19.627 37.75 0 0 0
108 ENVELOPE Combination Max 5.743 6.766 421.932 0 0 0
108 ENVELOPE Combination Min -13.464 -20.123 67.129 0 0 0
109 ENVELOPE Combination Max 0.026 2.331 251.861 0 0 0
109 ENVELOPE Combination Min -49.999 -19.411 22.379 0 0 0

9.6.6.2 Soil Parameter From Soil Investigation

244
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.6.7 Summary

Upper Structure:

o Column: WF 400x200x8x13

o Primary Beam: WF 300x150x8x13

o Secondary Beam: WF 250x125x6x9

o Pedestal: Concrete 500x500

o Tie Beam: Concrete 200x300

o Roof Plate: Concrete 12mm

Foundation: Foot Plate Foundation 1,8x1,8x0,35 m

Quarantine Foundation Plan

Quarantine Roof Plan

245
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.7 SECURITY POST

9.6.1 Load Assign

Load assign are the load that are assigned to the structure so the
structure can handle the load safely. There are 6 different types of loads
that are assigned to the structure of this building. These are: Dead, SIDL,
Live, Wind, Quake and Live roof. The figure below shows load that are
assigned to the building structure.

o Live load on the roof without access 100 kg/cm 2

o SIDL on the roof 198 kg/cm2

o SIDL on tie beam 10.98 kg/cm2

o Wind load 77kg/m2

Quake Load Using Auto Lateral Seismic IBC

9.6.2 Element Forces

Element force is a force that exists inside the element (beam or column). It
consists of 3 forces: Axial, Shear and Moment. The design must handle all these

246
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

three kind of force. The figure below shows how much force that works inside the
element.

Axial Force

Major Shear

Minor Shear

247
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Major Moment

Minor Moment

Torsion

9.6.3 Deflection

Deflection is the degree to which a structural element is displaced under


a load. It may refer to an angle or a distance. The deflection distance of a
member under a load is directly related to the slope of the deflected
shape of the member under that load and can be calculated by
integrating the function that mathematically describes the slope of the
member under that load.

248
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Deformed Structure

9.6.4 Mode Shape

Mode shape is a specific vibration pattern that runs by a mechanical


system at a certain frequency. Forms mode different shape, it is
associated with the frequency of different objects. In the process of
designing a structural system, it is important for planners to determine
the mode shape of the structure of the system to avoid the dominant
variety in the structure. In this case, the mode shapes that happen must
be translation at mode shape 1 and 2. In the mode shape 3, it should be
rotation. Mode shape associated with natural frequencies. Mode shape for
Security building is shown with the figure below.

Mode 1

249
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Mode 2

Mode 3

9.6.5 Stress Ratio

The analysis result is shown by the ratio between the forces and capacity.
If ratio is more than 1, then the ratio color became red. If the color still
blue, green or maybe yellow, it means beam and column capacity has not
been exceed the ultimate forces and moment.

250
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Analysis Result For Security Post Building

9.6.6 Foundation Design

Maximum axial force for one restrain is 135,66 kN. So the foundation for
Security Post building is 1,5m X 1,5m X 0,35 m. (The detailed calculation
shown in the appendix.)

251
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Foundation Design For Security Post

9.6.6.1 Support Reaction

9.6.6.2 Soil Parameter From Soil Investigation

9.6.7 Summary

Upper Structure:

o Column: 400x400

o Primary Beam: 300x450

o Secondary Beam: 200x400

o Cantilever Beam: 150x500

o Tie Beam: Concrete 300x450

o Roof Plate: Concrete 12mm

252
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Foundation: Foot Plate Foundation 1,5x1,5x0,35 m

Security Post Foundation Plan

Security Post Roof Plan

253
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.8 SEWAGE TREATMENT PLAN

According to soil investigation, soil in Oecusse airport can resist 15 ton/m2 in 1.5m
depth.

Allowable Bearing Pressure

For STP foundation design, we use 1,5x from the total load of the tank include the
water inside it. From Mechanical designer, they want to use tank with 10m 3 capacity
so it means, the load from the tank itself is 10.000 kg or 10 ton. We use 15 ton for
the load design.

STP
CAPACITY 10 m3
LENGTH 6 m
WIDTH 2 m
HEIGHT 0.55 m
VOLUME 6.6 m3
DESIGN LOAD 15000 kg
ALLOWABLE LOAD 15840 kg
REBAR D16-150
STP calculation

254
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

STP Section Design

9.9 GROUND WATER TANK

According to soil investigation, soil in Oecusse airport can resist 15 ton/m2 in 1.5m
depth.

Allowable Bearing Pressure

For GWT tank foundation design, we use 1,2x from the total load of the tank include
the water inside it. From Mechanical designer, they want to use tank with 400m 3
capacity so it means, the load from the tank itself is 400.000 kg or 400 ton. We use
480 ton for the load design. But for the pump foundation we use 3x from the total
load. It because the pump have some vibration when operate, so we must anticipate
it. There are 3 different type of pump foundation. EFP-1&2 have 3000 kg for the
load design. BP-CW (PACKAGED) has 3000 kg for the load design and JFP-HS have
300kg for the load design.

GWT EFP-1&2 BP - CW (PACKAGED) JFP-HS


3
CAPCACITY 400 m CAPCACITY CAPCACITY CAPCACITY
LENGTH 15 m LENGTH 2 m LENGTH 2.7 m LENGTH 0.8 m
WIDTH 11 m WIDTH 1 m WIDTH 1 m WIDTH 0.8 m
HEIGHT 1.25 m HEIGHT 0.9 m HEIGHT 0.5 m HEIGHT 0.3 m
VOLUME 206.25 m3 VOLUME 1.4 m3 VOLUME 1.35 m3 VOLUME 0.192 m3
DESIGN LOAD 480000 kg DESIGN LOAD 3000 kg DESIGN LOAD 3000 kg DESIGN LOAD 300 kg
ALLOWABLE LOAD 495000 kg ALLOWABLE LOAD 3360 kg ALLOWABLE LOAD 3240 kg ALLOWABLE LOAD 460.8 kg
REBAR D25-150 REBAR D22-150 REBAR D16-150 REBAR D16-200

255
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

GWT Foundation Calculation

GWT Plan

GWT Foundation Section

EFP-1&2 Foundation Section

256
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

BP-CW (PACKAGED) Foundation Section

JFP-HS Foundation Section

257
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.10 DVOR

9.10.1 Load Assign

Load assign are the load that are assigned to the structure so the
structure can handle the load safely. There are 6 different types of loads
that are assigned to the structure of this building. These are: Dead, SIDL,
Live, Wind, Quake and Live roof. The figure below shows load that are
assigned to the building structure.

o Live load on the roof without access 100 kg/cm 2

o SIDL on the roof 198 kg/cm2

o SIDL on tie beam 10.98 kg/cm2

o Wind load 77kg/m2

Quake Load Using Auto Lateral Seismic IBC

258
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.10.2 Foundation Design

The foundation for DVOR building only use stone foundation, because the
load itself is not that heavy. So, no foot plate foundation is needed for
this building.

Foundation Design For Security Post

9.10.2.1 Soil Parameter From Soil Investigation

DVOR Plan

259
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

9.10.3 Generator and Transformer Foundation

According to soil investigation, soil in Oecusse airport can resist 15


ton/m2 in 1.5m depth.

Allowable Bearing Pressure

For generator, we use 3x weight for the foundation calculation but for the
transformer, because it doesn‘t vibrate, we use 1,5x weight for the
foundation. So here is the design for the generator and transformer
foundation.

Generator Foundation Plan

Transformer Foundation Plan

260
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

10. LANDSIDE ACCESS AND PARKING


10.1. Introduction
A good airport must have a good connection access within the area, and to make
the airport still reliable for the future, we have to know what is the target and
assumptions that has been made regarding the Oecusse Airport. A good airport
will never get traffic jam while it‘s operating.

10.2. Base Data and Assumptions


Based on ISQ TOR Document we found out that Oecusse Airport will serve
around 750.000 pax/year, it means around 2.054 pax daily passenger, and with
500 pax at peak hour. And also 100-150 employee for whole facilities at the
airport. Plus, because the airport will be a commercial area, so we considering an
additional 100 visitors for the airport.

10.3. Roads
Geometric Plan
Planning a road geometric centerline planning road that becomes a reference in
the implementation of the design work, geometric design is determined by the
type of vehicle that operates with standards and regulations.

Alignment Plan
Planning the road alignment consist of planning horizontal alignment, vertical
alignment of planning and also planning super elevation, which is associated with
the planned road design with a variable vehicle speed and other variables that
influence this alignment planning.

10.4. Curbside
Curbside at Passenger Terminal will have 3 lanes with 1 directions, the inner lane
is to drop and pickup passenger from and to the terminal. Middle lane is to
queuing before entering the inner lane. And then the outer lane is for passing by.

261
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

10.5. Road Marking


Road Marking Concept
Definition of road markings are a sign written or drawn on a road section with a
view to giving a hint, informs a condition (disorder / ban) and the limits of traffic
safety on the road. In the planning of road markings used standard taken from
the International Standard Product for Urban Road. Road markings are used to
the streets in Oecusse Airport - East Timor is as follows:
a. Dotted Line
1. Center Line And Divider
Two lanes, two directions (b> 5.50 m). Line Color: White.
V ≤ 60 km/hr.

2. Center Line Only


Two lanes, two directions (b> 5.50 m). Line Color: White.

3. Warning Line
For slowing down or to increase speed. Line Color : White.

4. Yield Line.
Line Color : White.

b. Solid Line
1. Centerline and divider
Line Color : White

262
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

2. Pavement Edge Line


Edge Inside Pavement. Line Color : White.

c. Zebra Cross
Zebra-Cross Concept

d. Signs
Signs on a road section is a symbol that is placed or installed in areas with a
road section which aims to provide road traffic information. The signs were
used on the streets in Oecusse Airport - Timor Leste under International
standards.

10.6. Car Parking


Based from the assumptions for the number of passenger on peak hour and the
possibilities for visitors, we calculate the Oecusse Airport should have 120
Parking Lot in front of Passenger Terminal.

10.7. Employee Parking


To establish a good work flow for the airport, we must consider easiness for the
employee from one facility to another. So we considered 28 car park and 32
motorcycle parking at west area, and 18 car park and 24 motorcycle park on east
area.

263
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

10.8. Car Rental Parking


Car Rental is necessary when passenger want transportation within the days to
travel or maybe doing some business from place to place. So we established
another 20 parking lots for Car Rental Parking in front of the Passenger Terminal.

10.9. BusStand
In Oecusse Master Plan, ZEESM-TL will build some leisure, hotels and another
Commercial Places. In case the hotels wants to added a shuttle services for their
customers so we provide 5 Bus Stands for the Oecusse Airport.

10.10. TaxiStand
To provide a good airport services for the Passengers, and their easiness to
travel from or to the airport, 36 taxi stand will serves and stands in front of the
Passenger Terminal.

10.11. Landside Pavements


PAVEMENT DESIGN (ACCESS ROAD AND PARKING AREA)
TRAFFIC LOAD
Traffic load is required for the road technique design, because the road capacity
which will be designed depends on the composition of traffic load later will be
used.
To determine the thickness of the road pavement structure, the average daily
traffic (ADT) to be calculated based on the criteria and assumption. In designing
the daily traffic for individual road is different as the type of vehicle passing the
said road are various. For inspection road the type of vehicle passing the said
road consisting of passenger vehicle, inspection vehicle and fire fighting vehicle
and ambulance vehicle.

264
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

GRADING AREA
Grading area to be executed at the road design area in the form of compacted
soil and leveled soil with various slopes in accordance with the requirement. The
surface of grading area should able to flow the rainy water (the surface water) to
the drainage so that there is no water pounding at the grading area.
Height of surface plan (leveling) is based on the volume of excavation and
embankment as small as possible, and therefore able to minimize construction
costs but still meet the requirements of the drainage system by taking into
account the maximum flood water level.
The following items should be considered in the leveling design;
a. No flood or water pounding at the road facilities and other facilities during the
rainy season.
b. The surface of the existing soil and most of the part of the design land has
various elevations from the lowest one till the highest against the average of
surface of sea level (mean sea level).
c. In order to reduce the volume of the soil work (pile and excavation) and to
facilitate the drainage so the slope to be used at the surface of road
pavement with the slope 1 % and the road shoulder 2% - in repairing the
existing slope.

Determination on the height depends on some factors such as: the elevation of
the road design, drainage necessity, related with inter facilities, material supply
for piling and place for excavation discard and etc.

A. FLEXIBLE PAVEMENT PARAMETERS


Pavement for airside area road use flexible pavement type. Here are the
components used in road pavement design :

a. Regional Factor (RF)


Regional factor is affected by the form of alignment (slope and curve),
percentage of heavy vehicle and season (rainy season)
Based on the alignment path with a slope I (< 6%), percentage of heavy
vehicles ≤ 30% and type I climate (rainfall > 900 mm/year), then RF =
1.5

Table 1 - Regional Factor

Source: AASHTO 1993

265
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

b. Index of Pavement Surface (IPs)


Index of pavement surface (IPs) as a basic size in determining the value
of pavement in relation with the necessity of traffic. The Index of
Pavement surface indicating the average value/smoothness and the
surface resistance in relation with the improvement of service for the
passing traffic.
With Equipment Single Axle Load (ESA) 100-1000 so as to obtain the
value type local road IPs = 2.0

Table 2 - Index of Pavement Surface

Source: AASHTO 1993

Coefficient of vehicle distribution passing the Ground Support Equipment


(GSE) road at Oecusse Airport, to be designed 2 lanes and two directions
consisting of;
1. Total weight < 5 ton (light vehicle) = 0.50
2. Total weight  5 ton (heavy vehicle) = 0.50

c. Index of Pavement Surface at Early (IPo)


Pavement surface layer is Asphalt Concrete (AC-WC) with the IPo = 3.5
to 3.9.

d. Vehicle Distribution Coefficient (C)


Coefficient of vehicle distribution for both light and heavy vehicles
passing the design route, planned for light vehicles = 0.5 (2 way, 2 lane)
and for heavy vehicles = 0.5 (2 way, 2 lanes).

e. Design Life and Traffic Growth of Road


Life time of road design is the number of time (in year) calculated from
the opening of the said road until at the moment it is required for heavy
repairing or to be assumed that new layer is needed. The life time of the
road design to be applied in this designing is 10 (ten) years. Traffic
Growth taken based on the assumption of growth in passenger and
aircraft movements, the assumption of growth is 4%.

266
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

f. Planned Subgrade CBR


Bearing capacity of Subgrade (DDT) to be determined based on the
correlation graph between CBR and DDT (graph as per attached). Based
on the report of Soil Investigations on site showing the soil condition at
location or the existing soil is good enough. To design this pavement
structure - Design CBR value 8 % is to be applied.
Soil settlement can cause problem at the project area. Therefore one
aspect of the soil improvement method proposed in the soil improvement
report is to limit the settlement that probably will occur in this area.
In addition to settlement problem, the soil improvement method is also
focused on getting the CBR of subgrade of 8% which is required for
pavement design. It is assumed that for the worst condition the CBR of
the existing soil is less than 8%. Therefore, this CBR needs to be
increased to 8% as required for the pavement design. Subgrade of the
existing soil can be improved by method remove and replace. This means
that the upper of the existing soil is removed and then replaced with
good selected material. The selected fill material is then compacted to at
least 95% of its dry density. The selected fill material at least canbe
obtained from the excavated materials from quarry area.

g. Component Analysis of Road Pavement


Design calculation is based on the relative strength of each layer of the
long-term pavement, where the pavement thickness determination
expressed by the following formula:

ITP = a1D1 + a2D2 + a3D3

a1 = relative strength coefficient of surface course


a2 = relative strength coefficient of base course
a3 = relative strength coefficient of sub base course
D1 = thickness of surface course
D2 = thickness of base course
D3 = thickness of sub base course

Figure 1 - Composition of the Flexible Pavement

267
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

h. Relative Strength Coefficient


In determining the composition of pavement used table 4 and table 5.
Table 4 - Relative Strength Coefficient

Source: AASHTO 1993

Table 5 - Limits of Minimum Thickness Pavement Layers

Source: AASHTO 1993

i. Equivalent Single Axel Loads


Equivalent Single Axel Loads each vehicle is determined by the following
formula

NumeralEquivalent SingleAxis 
SingleAxisLoad (kg )4
8160

Table 6 - Numeral Equivalent Single Axle Vehicles


Load One Axis Numeral Equivalent
Kg Lbs Single Axis Dual Axis
1.000 2.205 0,0002 -
2.000 4.409 0,0036 0,0003
3.000 6.614 0,0183 0,0016
4.000 8.818 0,0577 0,0050
5.000 11.023 0,1410 0,0121
6.000 13.228 0,2923 0,0251
7.000 15.432 0,5415 0,0466
8.000 17.637 0,9238 0,0794

268
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

8.160 18.000 1,0000 0,0860


9.000 19.841 1,4798 0,1273
10.000 22.046 2,2555 0,1940
11.000 24.251 3,3022 0,2840
12.000 26.455 4,6770 0,4022
13.000 28..660 6,4419 0,5540
14.000 30.864 8,6647 0,7452
15.000 33.069 11,4148 0,9820
16.000 35.276 14,7815 1,2712

Source: AASHTO 1993

Table 7 – Numeral Equivalent for Each Type of Vehicle


One Axis Load Numeral Equivalent
Load
Type of Vehicle Rear/ Rear/
( kg ) Front Front Total
Behind Behind

Towing Tractor 15.000 7.000 8.000 0,5415 0,9238 1,4653

Fuel Truck 13.000 6.000 7.000 0,2923 0,5415 0,8338

Cargo Dolly Train 10.000 5.000 5.000 0,1410 0,1410 0,2820

Sweeper Car 2.000 1.000 1.000 0,0002 0,0002 0,0004

Truck Basin 10.000 5.000 5.000 0,1410 0,1410 0,2820

Source : Consultant Analysis, 2011

B. PAVEMENT DESIGN OF MAIN ACCESS ROAD


Characteristics of traffic in the area around and inside the landside area will
be divided into 3 (three) pavement types of the road. These roads are :
a. Main Access Road
b. Access Road (to office building)
c. Parking Road

The Main Access road in landside area is dominated by passenger cars (light
vehicles) and bus, others vehicles are Fuel Truck and Cargo Truck.
Characteristics of traffic on landside area base on the traffic of passenger and
aircraft movement per day. From the characteristic movement of trafficwill
also determine pavement design parameters.

a. Types of vehicles that operate at early of design life:


1. Light vehicles (2 ton) = 4813 vehicle/day
2. Fuel Truck (13 ton) =24 vehicle /day
3. Cargo Truck = 24 vehicle /day
4. Bus (8 tons) = 7 vehicle / day

b. Configuring the vehicle axle load are :


1. Light vehicles 2 tons = (1+1) tons
2. Fuel Truck 20 tons = (4+8.8) tons
3. Cargo Truck 20 tons = (4+8.8) tons

269
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

4. Bus 8 tons = (3+5) tons

c. Equivalent single axle load are :


1. Light vehicles 2 tons (1+1) = 0.0004
2. Fuel Truck 20 tons (4+8.8) = 1.3289
3. Cargo Truck 20 tons (4+8.8) = 1.3289
4. Bus 8 tons (3+5) tons = 0.1593

Pavement for Access Road use type of flexible pavement. Here are the
components used in road pavement design :

a. Regional Factor (FR)


Based on the alignment path with a slope < 6%, percentage of heavy
vehicles ≤ 30% and type I climate (rainfall > 900 mm/year), then RF
= 1.5.

b. Index of Surfaces (IPs)


With Equivalent Single Axle load 100-1000, so as to obtain the value
of the collector road type IPs = 2.0.

c. Index of Surfaces at Early Plan (IPo)


Planned type surface layer is Asphalt Concrete with the IPo = 3.9 to
3.5.

d. Vehicle Distribution Coefficient (C)


Planned for light vehicles = 0.5 (2 direction, 2 lane) and for heavy
vehicles = 0.5 (2 direction, 2 lanes).

e. Design life of road is 10 (ten) years

f. Traffic growth at 7 % per year


From subgrade CBR value 6 %, then DDT value 5.0 determined.

270
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

g. Design Traffic
 Equivalent Single Axle at initial of Design Life (LEP)
Light vehicles 2 tons =0.0004 x 0.5 x 4813 =0.96
Fuel Truck 13 tons = 1.3289 x 0.5 x 24 = 15.76
Cargo Truck 13 tons = 1.3289 x 0.5 x 24 = 15.76
Bus 8 tons (3+5) tons = 0.1593 x 0.5 x 5 =0.52
Total = 33.00

 Equivalent Single Axle at end of Design Life (LEA)


Light vehicles 2 tons = 0.0004 x 0.5 x 9468 = 1.90
Fuel Truck 13 tons = 1.3289 x 0.5 x 47 = 31.01
Cargo Truck 13 tons = 1.3289 x 0.5 x 47 = 31.01
Bus 8 tons (5+3) tons = 0.1593 x 0.5 x 13 = 1.03
Total =64.95

Design Traffic LER = (LEP + LEA)/2


= (33.00 + 64.95)/2
= 48.98

The composition of the flexible pavement thickness

ITP = a1D1 + a2D2 + a3D3

6.00 =0.3x 5 + 0.13x 15 + 0.11x D3


6.00 = 1.5 + 1.95 + 011x D3
D3 = (6.00 - 3.45)/0.11 = 23.18  Use D3 = 25 cm.
D1 = 5 cm (AC-WC, MS ≥ 340 kg)
D2 = 15 cm (Crush Aggregate Base Course, CBR ≥ 80 %)

271
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

D3 = 25 cm (Sandy Gravel, CBR ≥ 30%)

Figure 2 - Structure Pavement Of Main Access Road

Figure 3 - Figure Nomogram Road of Main Access Road

C. PAVEMENT DESIGN OF ACCESS ROAD


Characteristics of traffic in the area around and inside the landside area will
be divided into 3 (three) pavement types of the road. These roads are:
1) Main Access Road (and Drop Off)
2) Access Road (to office building)
3) Parking Road

The Access road to office building in landside area is dominated by passenger


cars (light vehicles) and bus, others vehicles is Cargo Truck. Characteristics
of traffic on landside area base on the traffic of passenger and aircraft
movement per day. From the characteristic movement of trafficwill also
determine pavement design parameters.

a. Types of vehicles that operate at early of design life:


1. Light vehicles (2 ton) =4813 vehicle/day
2. Cargo Truck = 24 vehicle /day
3. Bus (8 tons) = 7 vehicle / day

b. Configuring the vehicle axle load are :


1. Light vehicles 2 tons = (1+1) tons
2. Cargo Truck 20 tons = (4+8.8) tons
3. Bus 8 tons = (3+5) tons

272
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

c. Equivalent single axle load are :


1. Light vehicles 2 tons (1+1) = 0.0004
2. Cargo Truck 20 tons (4+8.8) = 1.3289
3. Bus 8 tons (3+5) tons = 0.1593

Pavement for Access Road use type of flexible pavement. Here are the
components used in road pavement design:

a. Regional Factor (FR)


Based on the alignment path with a slope < 6%, percentage of heavy
vehicles ≤ 30% and type I climate (rainfall > 900 mm/year), then RF =
1.5..

b. Index of Surfaces (IPs)


With Equivalent Single Axle load 10-100, so as to obtain the value of the
collector road type IPs = 2.0.

c. Index of Surfaces at Early Plan (IPo)


Planned type surface layer is Asphalt Concrete with the IPo = 3.9 to 3.5.

d. Vehicle Distribution Coefficient (C)


Planned for light vehicles = 0.5 (2 direction, 2 lane) and for heavy
vehicles = 0.5 (2 direction, 2 lanes).

e. Design life of road is 10 (ten) years

f. Traffic growth at 7 % per year


From subgrade CBR value 6 %, then DDT value 5.0 determined.

273
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

g. Design Traffic
 Equivalent Single Axle at initial of Design Life (LEP)
Light vehicles 2 tons = 0.0004 x 0.5 x 4813 =0.96
Cargo Truck 13 tons = 1.3289 x 0.5 x 24 = 15.76
Bus 8 tons (3+5) tons = 0.1593 x 0.5 x 7 = 0.52
Total = 17.24

 Equivalent Single Axle at end of Design Life (LEA)


Light vehicles 2 tons = 0.0004 x 0.5 x 9468 = 1.90
Cargo Truck 13 tons = 1.3289 x 0.5 x 47 = 31.01
Bus 8 tons (5+3) tons = 0.1593 x 0.5 x 13 = 1.03
Total = 33.94

Design Traffic LER = (LEP + LEA)/2


= (17.24 + 33.94)/2
= 25.59

The composition of the flexible pavement thickness

ITP = a1D1 + a2D2 + a3D3

5.35 = 0.3x 5 + 0.13x 15 + 0.11x D3


5.35 = 1.5 + 1.95 + 011x D3
D3 = (5.35 - 3.45)/0.11 = 17.27  Use D3 = 20 cm.
D1 = 5 cm (AC-WC, MS ≥ 340 kg)
D2 = 15 cm (Crush Aggregate Base Course, CBR ≥ 80 %)
D3 = 20 cm (Sandy Gravel, CBR ≥ 30%)

Figure 2 - Structure Pavement Of Access Road

274
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Figure 3 - Figure Nomogram Road of Access Road

D. PAVEMENT DESIGN OF PARKING AREA


Characteristics of traffic in the area around and inside the landside area will
be divided into 3 (three) pavement types of the road.
These roads are:
1) Main Access Road (and Drop Off)
2) Access Road (to office building)
3) Parking Area

The road to parking and parking area pavement in landside area is


dominated by passenger cars (light vehicles) and bus. Characteristics of
traffic on landside area base on the traffic of passenger and aircraft
movement per day. From the characteristic movement of trafficwill also
determine pavement design parameters.

a. Types of vehicles that operate at early of design life:


1. Light vehicles (2 ton) = 4813 vehicle/day
2. Bus (8 tons) = 7 vehicle / day

b. Configuring the vehicle axle load are :


4. Light vehicles 2 tons = (1+1) tons
5. Bus 8 tons = (3+5) tons

c. Equivalent single axle load are :


1. Light vehicles 2 tons (1+1) = 0.0004
2. Bus 8 tons (3+5) tons = 0.1593

275
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Pavement for Parking Road use type of flexible pavement. Here are the
components used in road pavement design:

a. Regional Factor (FR)


Based on the alignment path with a slope < 6%, percentage of heavy
vehicles ≤ 30% and type I climate (rainfall > 900 mm/year), then RF =
1.5.

b. Index of Surfaces (IPs)


With Equivalent Single Axle load 10-100, so as to obtain the value of the
collector road type IPs = 2.0.

c. Index of Surfaces at Early Plan (IPo)


Planned type surface layer is Asphalt Concrete with the IPo = 3.9 to 3.5.

d. Vehicle Distribution Coefficient (C)


Planned for light vehicles = 0.5 (2 direction, 2 lane) and for heavy
vehicles = 0.5 (2 direction, 2 lanes).

e. Design life of road is 10 (ten) years

f. Traffic growth at 7 % per year


From subgrade CBR value 6 %, then DDT value 5.0 determined.

g. Design Traffic
 Equivalent Single Axle at initial of Design Life (LEP)
Light vehicles 2 tons = 0.0004 x 0.5 x 4813 = 0.96
Bus 8 tons (3+5) tons = 0.1593 x 0.5 x 7 = 0.52
Total = 1.48

 Equivalent Single Axle at end of Design Life (LEA)

276
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Light vehicles 2 tons = 0.0004 x 0.5 x 9468 = 1.90


Bus 8 tons (5+3) tons = 0.1593 x 0.5 x 13 = 1.03
Total = 2.93

Design Traffic LER = (LEP + LEA)/2


= (1.48 + 2.93)/2 = 2.21

The composition of the flexible pavement thickness

ITP = a1D1 + a2D2 + a3D3

3.75= 0.3x 5 + 0.13x 15 + 0.11x D3


3.75=1.5 + 1.95 + 011x D3
D3 = (3.75 - 3.45)/0.11 = 2.72  Use D3 = 15 cm.
D1 = 5 cm (AC-WC, MS ≥ 340 kg)
D2 =15 cm (Crush Aggregate Base Course, CBR ≥ 80 %)
D3 = 15 cm (Sandy Gravel, CBR ≥ 30%)

Figure 2 - Structure Pavement of Parking Area

Figure 3 - Figure Nomogram Road of Main Access Road

277
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

11. ANCILLARY AND SUPPORT FACILITY


11.1. Main Power House
This Operational Area Assumption comes from the initial Airport Scope developed
by ISQ, and it intends to provide a dedicate area for the Supply of Electric Energy
to all Airport facilities.This area establishes the connection between the Public
Electric Energy EDTL and the Electrical Energy distribution system of the airport,
a system where power is available, transformed and distributed to supply all
airport infrastructures.As a secondary power supply, an Emergency Energy
Supply strategy must be considered for the Oecusse International Airport,
combined with the existent (initial projected) to achieve quality power to the
whole airport electrical installations.Adequate and coordinated electrical fault
Cleanance time between different electrical infrastructure supplies must be
specified by the Consultant, according to the applicable codes and
regulations.The Main Power Station it‘s located on the West Side with controlled
access. This will be align according the Master Plan guidance, where a
infrastructure supply Channel is indicated on West Side under crossing of Electric
high voltage cables network, and other infrastructure supplies.

Main Power House Location

Main Power House Layout and Equipment


ITEMS UNIT
Generator Set 1500 kVA 2
Generator Set 450 kVA 1
Transformer 1600 kVA 2
Transformer 450 kVA 1
Daily Diesel Tank (10000 L) 1
Monthly Diesel Tank (50.000 L) 1

278
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

11.2. GSE Maintenance Complex


The Airport Maintenance Complex accommodate the service of Ground Service
Equipment and Airport Maintenance, because this facility will have a shared
operating company‘s personnel. This complex should have dedicate offices,
maintenance and storage areas for each activity, therefore should be considered
an industrial hanger with comprising of workshop and dedicate maintenance bays
for airfield signage, navigation aids, lighting system and Ground Service
Equipment.

GSE Shelter and Parking Location


The requirement for the facilities maintenance building as the described for the
Airfield Maintenance, with workshops capable of accommodating all facilities
maintenance activities such as mechanical, electrical (buildings, streetsetc.) ,
plumbing, HVAC, carpentry, welding and signage (buildings, streets).
Administration and storage area. Paint booth and sand blasting rooms capable of
painting and stripping small items such, as airfield signage shall be provided
along with material, part and components, equipment, hazardous material and
flammable liquids storage shall be provided. This area fitted for hydraulic lifts,
access pits and overhead cranes. The shelter not overcome 10m height and has
sliding doors with a height more than 6 meters. According the new Masterplan,
the area located Southeast to Runway location, between Passenger Terminal and
the Cargo Terminal Complex is the most suitable, because the kind of facilities
should be accessed by service roads on the Airside and have a controlled access
by the Landside for possible maintenance material replacement, to achieve is
fully operational capacity.

279
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

GSE Building Layout

11.3. Quarantine Building


This service will support the operational service on the Passengers Terminal and
Cargo Facility Complex. This quarantine Service Area is dimensioned and located
with a primary assumption of Animal and Perishable Goods Transport. Its assume
by the Consultant (ISQ) under the Owner supervision, that this transport
Operation will be one of the most important Airport demands for the future
Oecusse economy development.

Quarantine Building Location


Therefore the review design and comments launch on this document are on the
initial scoped, Masterplan location general dimension and is link to Oecusse Road
system network. The construction foot print considered is about 250.00 sqm with
dedicated parking lot with 5 spaces for card and 2 spaces for trucks. This area
have an interior controlled access with dedicated areas as offices, toilets, rest
room, storage rooms and a reception. A perimeter fence must be considered with
a total area of 500sqm. The location of this facility is on the East side of Oecusse
Airport according the develop Master Plan, this facility works with independent
procedures according the Laws and regulations applied. The access to this area
will be controlled by the Main Security Gate.

Quarantine Building Layout

280
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

11.4. Aviation Fuel Storage Facility


The development of the Oecusse-Ambeno Administrative Region (RAEOA),
integrated in the Special Zones of Social Market (ZEESM) aims at providing a new
centrality and associated development for a twofold insular region of Timor-
Leste. Timor is an island and Oecusse- Ambeno is an enclave located in the West
Timor Indonesian NTT Province making the connection between Oecusse-Ambeno
and the mainland of Timor-Leste difficult, costly, and time consuming. In order to
provide Oecusse-Ambeno with easier access, required for its development, and to
provide for the needs of its population, it was determined that an International
Airport was to be built, capable for providing direct, easy, cost-efficient, safe and
regular access to and from Oecusse-Ambeno, not only from Dili also from a range
of international airports of origin/destinations. To cater for these needs, Oecusse
International Airport requires that its Master Plan contemplates the design and
construction of an aviation fuel depot, and designed to comply with the best
aviation standards in terms of safety and environment protection. The project
requirement is to service fuel aviation fuel consumption are as follow:

Fuel Depot Location

Fuel Depot Layout

 Aviation fuel requirements


o Aircraft assumption :
 4 aircraft code C strands together at the same time
 2 aircraft code C and 1 code E strands at the same time

281
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

o General aviation (no feasible forecast)


o Helicopter : 2 aircraft considered on original scope
 Ground Support fuel requirements
o Ground Support aircraft tanker :
 minimum 4 tanker truck for 4 parking strands
o Ground Support Equipment (GSE) assumption :
 2 baggage/cargo tow tractor
 8 closed baggage carts
 1 aircraft pushback and tow tractor
 Jet engine air start unit
 2 cleaning service car
 1 lavatory service car
 1 ground power unit
 2 passenger stair truck
 4 caster bed pallet trailer
o o Rescue & Fire Fighting Services (RFFS) assumption :
 2 fire fighting vehicles
 1 ambulance
 4x4 vehicle
The layout components requirements are assumed as preliminary as follow:
 Aviation fuel depot dedicated area – 600m2 (20m x 30m)
 Minimum storage 80,000 Liters of aviation Fuel Jet A-1 (ø3.8x7.1m)
 Minimum storage 3,000 Liters of AVGAS 100LL (ø2.28x1.4m)
 Adequate and dedicate pump, filter & water separate system
 Unloading area from refinery
 Loading area to aviation Fuel system & Ground Support Fuel
 Fire fighting system internal of Fuel Farm
 Offices (20m2)
 Control post (3m2)
 Landside access from security gate
 Perimeter fence
 Water Separator System
 Oil Trap
 4 Parking Space for 10.000 L Tank Truck each

11.5. Security Post


In order of having good security and to separate between Public Area, Restricted
Area and Air Side Area, Oecusse Airport will have 4 Security Posts. Each of them
will facilitated with Toilet, Detention Room for any suspicious people, CCTV
Room.

282
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

283
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

12. SITE CHARACTERISATION


12.1. Seismicity

The following zoning earthquake in Timor East in accordance with Earthquake


Security Procedures for Building Design.

For design, we use:

For regular buildings, the earthquake load nominal, Earthquake Plan shown as
nominal static equivalent earthquake load (Fi), which captures the center of mass of
the floors level. Base Shear Static Load Nominal Equivalent (V)

V = C1.I.Wt
R
With:

Wt = Total weight of the building including live load reduce.

284
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

C1 = Response factor earthquake. Earthquake Spectral Response Plan


is attached at the time of fundamental natural period (T1).

T1 = Natural Period

= 0.06 H¾

H = Height of the building from the level of the lateral clamping

I = Virtue Factor

R = Earthquake Reduction Factor

Nominal load static equivalent earthquake (Fi)

Fi =Wi zi V
∑ Wi zi
With:

V = Nominal Base Shear.

Fi = Earthquake load nominal on the floor - i.

Wi = Weight Floor Level– i.

zi = High level floor – I of the level of lateral clamping.

12.2. Drainage

GENERAL

The drainage of airport has its function to reduce the water effect to the airport
so that there is no water stagnant in its area and to maintain the soil bearing
under the pavement due to the soil water effect. Soil and drainage net for airport
to be designed in accordance to the existing topography slope namely to the
direction yet by considering the spreading of the water debit is more divided
evenly. Drainage system of the Oecusse Airport to be developed based on the
following consideration:

 To use the soil slope based on the topography condition and to use optimally
the existing drainage and not make major revision.

 Determination on the layout system of the area to be developed in accordance


with the layout, segment system or the existing road net located on the
Oecusse Airport.

DESIGN STANDARD
Designing system of drainage to be executed at Oe-Cusse airport refer to the
standard of Airport Drainage Advisory Circular AC No. 150/5320-5B, Department
of Transportation FAA. Drainage net of rain water to be designed to free the
airport area developed against the effect of stagnant water and the effect of soil
water to the tolerance limit permitted.

285
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

ANALYSIS METHOD
To design the drainage system of the Oecusse airport required the hydrology
analysis and Hydraulic analysis. The main purpose of hydrology analysis is to
determine the designed flood debit based on the rain data located at the study
area. Whereas the hydraulic analysis to be carried out to design the structural
component of drainage such as drainage dimension, channel or box culvert.

HIDROLOGY ANALISYS

Rain Frequency Analisys

Rain frequency analysis to be carried out by applying the method of log pearson
type III which the calculation result has already been tested compared with the
other method.

 (log R )  1 / nx log R 


2 2


t
Sx
(n  1)

Rt  log R  ( KxS x )
R = Anti log Rt
Log R = Average value of log R
K = Coeficient of pearson table, in accordance with the number of
asimetric coeficient (Cs)
Sx = Standard deviation

Rain Intensity
Rain intensity analysisusing the Mononobe formula as mentioned below;
2

 R   24  3
I t   24  x 
 24   t c 
I = Rainfall intensity (mm/hour)
tc = Duration of rainfall (minute)
R24 = Maximum rainfall within 24 hour (mm)

Flood Debit Analysis


To calculate the flood debit to be designed - by applying the Rational Method
which is suitable to the study area. Flood debit to be analyzed on each union
point of the drainage where at the said point the increasing water occurred due
to the increasing catchment area.
The formula of rational method for flood designed as follows;

Q  C.I . A
Q = Flow debit (m3/sec)
C = Flow coeficient

286
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

I = Average rain intensity (mm/hr), for the same duration using the
concetrate time (tc) andcertain repeated period.
A = Area of catchment (Ha)

Time Concetrate (tc)

Time concentrate is a time needed by the rainwater to flow from the farest
point until the point to be observed locate at the flowing area or where the
maximum debit to be obtained. Where the concentrate time is the total of time
required by the water to flow to the closest drainage (to) and time required by
the water flowing inside the drainage to the point to be observed (td) and to be
written as follows;

tc  to  t d
Overland Time of Flow (to)

Time required by the water to flow from the soil to the closest drainage. In
calculation, tocalculated based on the formula:

- For the smallest flow area using the perineum along ± 300 m.

1
2
3.26.(1.1C ).( Lo )
to  1
(So ) 3

- For the small flow area using the perineum along 1000 m

1
3
108 .n.( Lo )
to  1
5
(So )
to = Time of runoff (minute)
n = Coeficient value of soil surface rough(table)
Lo = Length of runoff (m)
So = Slope of runoff area (%)

Table 1.Table of Roughness

Type of Surface n

Paved Surface 0,015

Open Surface of Soil 0,0275

Slightly Grass Surface 0,035

Medium Grass Surface 0,045

Thick Grass Surface 0,060

287
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Time of Drain (td)

Time required by the water to flow inside the drainage to the point to be

observed.

Tdis badly determined by the hydrolic charateristic inside the drainage where the
suitable formula applied as follows;

Ld
td 
Vd
Ld = Length of drainage (m)
Vd = Average debit inside drainage (m/s)

To calculate tdfor drainage capacity to be designed, the debit to be calculated


based on the debit formula of manning:

2 1
1
V  .R 3 .S 2
n
V = Speed (m/s)
n = Coeficient of manning roughness
R = Hydrolic radius
S = Slope

The above formula is preferable to be applied for artificial drainage with or


without lining.

Flowing Coeficient

Flowing coeficient is a comparison result between the number of the rainfall and
the number of the flowing water runoff. At a land use determined by taking the
average coeficient based on the size of the area. The formula to be applied for
calculating the flowing coeficient as follows:

Cr 
 C .A
i i

A i

Cr = Average flowing coeficient

Ci = Individual flowing coeficient

Ai = Individual area (ha)

Flowing Area

Flowing area is a contribution for the number of water run off volume by applying
the rational method. This area to be calculated based on the area tobe included
as a load to the drainage.

288
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Consideration for the flowing area covering;

- The current lay out of land and the future design

- Soil characteristic and the building constructed

- Soil slope and the form of the flowing area

HYDRAULIC ANALISYS

Drainage Capacity

To calculate the drainage capacity to be applied the formula of continuity of


manning.

Q= V * A

Q = Flowing debit (m3/sec)

A = Wet diameter/sectional (m2)

V = Flowing speed (m/sec)

Table 2.RoughnessCoeficient (n) for Manning Formula

Type of Drainage n

Concrete Slab/Layer 0.015

Stone Masonry 0.025

Without Pavement (regular) 0.030

Natural Drainage (irregular) 0.046

To calculate the depth of the flowing drainage in the form of square, the following
formula to be applied:

Y =0,7071.A

Y = The depth of flowing (m)

A = Area of wet diameter (m)

Drainage of Culvert

This is a crossing construction as the construction crossing the road. The design
of drainage based on the flowing debit volume in accordance with the condition of
drainage and the hydraulic charateristic.

Q  C.I . A
Q = Flowing debit (m3/sec)
C = Flowing coeficient

289
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

I = Average rain intensity (mm/hr), for the same duration with concentrate
time (tc) andcertain repeated period.
A = Catchment area (Ha)

Radius of pipe culvert with the form of radius using the following formula:

n.Q
R 0,375
2,513 .S
R = Radius of diameter (m)
Q = Flowing debit (m3/sec)
S = Slope of drainage/chanel (m/m)

Free Board

Minimum free board for drainage to be constructed as planned = 0,50. For


drainage with debit.

Table2. Free Board

Debit (Q) F (m) Polder (m)

Q < 5 m3/sec 0,20 – 0,30 0,75 – 1,00

10 m3/sec> Q > 5 m3/sec 0,30 – 0,50 1,00 – 1,25

Q > 10 m3/sec 0,70 – 1,00 1,25 – 1,50

Calculation on Flowing Volume

Total of flowing volume in t time, effective from the falling of rain applying the
following formula:

Tr  Qtr  Qtr   tr 
Vtr     tr .60 (m3)
 tr  2 

Vtr = Total volume of flowing in tr time (m3)

Qtr = Debit in trtime (m3/sec)

tr = Interval of observation (minute)

Suggested to apply :

tr = 10 minute, when A ≤ 200 Ha

tr = 30 minute, when 200 Ha ≤ A ≤ 500 Ha

tr = 10 minute, when A ≥ 500 Ha

290
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

NET SYSTEM OF DRAINAGE

Drainage system designed for rainwater, the flowing direction should follow the
existing slope of topography. The criteria as follows;

 Slope of the surface and the pavement of runway strip is 1,5%

 Addition of box culvert still be applied under the connection of runway.

 The base of drainage is soil layer in the form of stone and gravel compacted
so that water could absorb into the soil.

 Slope enforcement to be installed at the edge of drainage made of reinforcing


concrete with concrete quality minimum fc‘= 250 kg/cm2.

Drainage Facilities Required

a. Open Drainage

To make easy for maintenance most of the open drainage using stone
material. For different large elevation at the open drainage with various levels
with its function to absorb energy.

b. Box Culvert

On the connection airfield and inspection road using drainage in the form of
box culvert. And also under the taxiway.

Main Drainage Net

Drainage to be designed for 10 years repeated period, with the consideration that
the development of airport in the next years with sufficient capacity so that the
drainage dimension still could be resistance. The existing net design adopted
from the existing topography and directed to the left and right side and later to
be directed to the sea.

ANALYSIS AND CALCULATION

Design on Drainage Dimension

The catchment area of Oe-cussePante Makasar airport divided into 10 areas as


shown on the following tableas on the following page:

291
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Table 3Air Side Catchment Area

Area Total Area Total


Channel Surface Area (m 2)
(m 2) (km 2)

Ca01 Paved 19,369.6 56,747.5 0.056747


Turf 37,377.9
Ca02 Paved 14,659.1 55,598.2 0.055598
Turf 40,939.1
Ca03 Paved 18,659.5 67,939.2 0.067939
Turf 49,279.6
Ca04 Paved 12,225.8 59,835.6 0.059836
Turf 47,609.7
Ca05 Paved 12,411.7 56,113.6 0.056114
Turf 43,701.8
Ca06 Paved 39,105.1 60,895.1 0.060895
Turf 21,790.0
Ca07 Paved 19,092.4 66,401.5 0.066401
Turf 47,309.1
Ca08 Paved 19,792.4 60,128.2 0.060128
Turf 40,335.8
SD Paved 27,500.0 27,500.0 0.027500
Turf -
UG Paved 11,500.0 11,500.0 0.011500
Turf -
Ca09 Paved 864.0 3,639.6 0.003640
Turf 2,775.6
Ca10 Paved 4,810.5 6,452.3 0.006452
Turf 1,641.8
Ca11 Paved 50.0 300.0 0.000300
Turf 250.0
Ca12 Paved 50.0 300.0 0.000300
Turf 250.0

Table 4Land Side Catchment Area

Area Total Area Total


Channel Surface Area (m 2)
(m 2) (km 2)

Ca01 Paved 19,369.6 56,747.5 0.056747481


Turf 37,377.9
Ca02 Paved 14,659.1 55,598.2 0.055598187
Turf 40,939.1
Ca03 Paved 18,659.5 67,939.2 0.067939154
Turf 49,279.6
Ca04 Paved 12,225.8 59,835.6 0.059835584
Turf 47,609.7
Ca05 Paved 12,411.7 56,113.6 0.056113553
Turf 43,701.8
Ca06 Paved 39,105.1 114,196.1 0.114196079
Turf 75,091.0
Ca07 Paved 19,092.4 66,401.5 0.066401496
Turf 47,309.1
Ca08 Paved 19,792.4 60,128.2 0.060128186
Turf 40,335.8
SD Paved 27,500.0 27,500.0 0.027500000
Turf -
UG Paved 11,500.0 11,500.0 0.011500000
Turf -

The dimension of drainage for Ca01 refer to the dimension of drainage of Ca02
caused there is debit accumulation at Ca01 coming from the Ca02 drainage. As a
result the design of dimension planned based on the debit accumulation namely

292
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

from the drainage of Ca02 and catchment area of Ca01drainage.Similarly the


Ca04 drainage, wherein the debit accumulated from Ca03 drainage. The
dimension of drainage for Ca05 refer to the dimension of drainage of Ca06 due to
at Ca05 occur debit accumulation coming from Ca06 drainage. So that the design
of dimension planned based on the accumulation debit namely from Ca06
drainage and catchment area of Ca05 drainage.Also for Ca08 drainage where the
drainage debit accumulated from the Ca07 drainage. Whereas the debit
accumulated from Ca03 drainage.

Calculation Analysis of Drainage Capacity

The main drainage flow the overflow water from runway and its surrounding later
the flowing directed to the end of airfield at north side joining the existing
drainage at the road side later directed to the sea. The dimension of drainage
planned is a drainage with trapezium shape as a result the following formula to
be applied on the next page:

V = speed inside the drainage (m/sec)


n = roughness coefficient of manning drainage in accordance with the
drainage material
R = radius of circle of hydraulic (R = A/P)
P = cross section wet/wet diameter(m)
S = slope of drainage
Q = debit (m3/sec)
A = area of wet diameter of drainage
Comparison of width of drainage base with the water height recommended based
on the drainage capacity.

Table 5.Comparison of Drainage Capacity

Drainage Capacity (m3/sec) b : h

0.0 – 0.5 1.0


0.5 – 1.0 1.5
1.0 – 1.5 2.0
1.5 – 3.0 2.5
3 – 4,5 3.0
4.5 – 6.0 3.5
6.0 – 7.5 4.0
7.5 – 9.0 4.5
9.0 – 11.0 5.0

293
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Source : Imam Subarkah, Hydrology for Water Building Planning, Bandung 1980

Diameter of trapezium drainage

In this case the formula to be applied;

The slope of the drainage wall based on the material to be used

Figure 1. Slope of Drainage Bottom

Diameter area (A) = (b+mh) h


Wet diameter (P) = b + 2h 1+m2
Radius of circle of hydraulic (R) = A/P
Freeboard = 25 %

Drainage/Culvert

Drainage/Culvert (box or pipe) is needed to flow the water from the drainage
crossing the taxiway and fire fighters equipments road also inspection road.

Rainfall Data

294
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Result of Rainfall Frequency

Repeated
Rainfall
GUMBEL MODIFICATION LOG PEARSON III
HASPERS' METHOD
IWAY KADOYA'S
Periodic
(t)
2 82.900 + - 0 82.940 82.940
5 83.250 + - 0 82.956 83.186
10 83.481 + - 0 82.964 83.315
25 83.773 + - 0 82.973 83.453
50 83.990 + - 1 82.979 83.542
100 84.205 + - 1 82.984 83.622

Result Calculation of Rainfall Intensity

INTENSITY DENCITY FLOW CURVE


180.00

160.00

140.00
Intensity (mm/h)

120.00

100.00

80.00

60.00

40.00

20.00

0.00
0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00

Time Of Concentration - Td (Hour)

Time Intensity per Yearly (mm/hour)

Minute Hours 2 5 10 25 50 100

15 0.25 208.896 209.776 210.358 211.095 211.641 212.183


30 0.50 131.596 132.151 132.518 132.981 133.325 133.667
45 0.75 100.427 100.850 101.130 101.484 101.746 102.007
60 1.00 82.900 83.250 83.481 83.773 83.990 84.205
75 1.25 71.441 71.742 71.942 72.193 72.380 72.566
90 1.50 63.265 63.531 63.708 63.931 64.096 64.260
105 1.75 57.086 57.327 57.486 57.687 57.836 57.985
120 2.00 52.224 52.444 52.590 52.774 52.910 53.046
135 2.25 48.280 48.483 48.618 48.788 48.915 49.040
150 2.50 45.005 45.195 45.320 45.479 45.597 45.713
165 2.75 42.235 42.412 42.530 42.679 42.790 42.899
180 3.00 39.854 40.022 40.133 40.274 40.378 40.482
195 3.25 37.783 37.943 38.048 38.181 38.280 38.378
210 3.50 35.962 36.114 36.214 36.341 36.435 36.528
225 3.75 34.345 34.490 34.586 34.707 34.797 34.886
240 4.00 32.899 33.038 33.129 33.245 33.331 33.417

295
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Catchment Area

Result of Calculation of Air Side Drainage Dimension

Result of Calculation of Air Side Drainage Dimension (continued)

Result of Calculation of Land Side Drainage Dimension

296
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Result of Calculation of Land Side Drainage Dimension

13. MECHANICAL

297
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

13.1. Mechanical and Plumbing


From this report the planning and design of the facility Oecusse service have the
objectives such as:
- Planning the design of building installations in accordance with applicable
regulations.
- Planning for the installation of building design in accordance with the needs
of the building and its human (visitors).
- Control the rescue against the dangers that occur in buildings.
- Keeping the comfort of the building function and human (visitor)

With the purposes and objectives of the planning and design of supporting
facilities, can be used also by the maintenance part of the building (building
maintenance).
Mechanical systems and electrical very important role in the function and
operation of buildings service Oecusse is, if planners and design facility
supporting not get support from the maintenance of the building, then the events
that will occur is damage to the mechanical systems and electrical systems that
will lead to goals beyond from the planning and design of supporting facilities.

a. OBJECTIVES
 Improves comfort function of the building to visitors and improve the
information management officer of buildings / building.
 Creating a mechanism for a system update technologies with renewable
systems.
 Rejuvenating their lighting system with LED lamps (energy saving).
 Ease of maintenance and seek Troubleshooting / disorder.
 Briefing of Team Owner / Owner Instruction.
b. GOALS
 Increased officer skills information and systems management.
 renewable mechanism for a system update information
 Updated Mechanical content Info, especially for Electrical technology
development.

13.2. Design Concept of Mechanical & Plumbing


2.1. General
In designing of mechancal / plumbing need the rules & regulations,
standard, system and criteria that should be followed for reach out the
perfect design and for pleasant, safety of the occupant of the building.

The rules & regulations, standard and criteria shall appropriate with the type
of the building that will be used.

298
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

2.2. Scope of Design


Scope of design that needed for a Building of Airport is as follow :

1. Design System of Plumbing


2. Design System of Fire Fighting
3. Design System of Ventilating & Air Conditioning
4. Design System Transportation in The Building

2.3. The standard that will be used


1. Plumbing Code
2. National Fire Protection Association (NFPA)
3. American Society of Heating Refrigeration and Air Conditioning
Engineers (ASHRAE)
4. Sheet Metal of American Contractors National Association (SMACNA)
5. Rules & Regulations of Regional Government

2.4. Design System


4.1. Design System of Plumbing

a. Design System of Clean Water

b. Design System of Waste Water, Soil Water and Vent.


a. Design System of Clean Water

Design System of Clean Water for this Buildings will use centralized
system where the Clean water for this buildings / occupant come
from the City water that will be connected to the area of Airport

Clean water from City water will be accommodated first in Central


Water Reservoir / Clean Water Tank.

The Clean water that had been accommodated in Central Water


Reservoir / Clean Water Tank. Afterwards will be distributed to
Toilets in the building of Terminal and also to toilets in the other
building by using the Distribution Pump / Booster Pumps

Each building will be equipped with toilets that contains such as :

Lavatory, Urinal, Water Closet, Faucets and other plumbing fixtures

For servicing The building of terminal, This building will be devided


in

4 ( four ) zone. Every zone have some toilets where Clean water
from distribution pump will supply to each zone and also will supply
to buildings such as : building of Main Power House, ATC &
Meteorology, Fire Rescue, Ground Service Equipment, Cargo and
Quarantine.

299
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

b. Design System of Waste Water / Soil Water

Waste water & soil water from Terminal Buildings such as : waste
water from toilet, lavatory, floor drain, sink, urinal, Water closet,
etc will be processed in a Sewage Treatment Plant. The effluent
water from Sewage Treatment Plant that already comply with
standard of expediency can be flowed to ditch of Airport Area
drainage system.

Both of pipes waste & soil water shall be provided with Venting
system. For servicing The building of terminal, This building will be
devided in 4 ( four ) zone.

Every zone have some toilets where waste water from each zone
will be accommodated in every sumpit that equipped with
submersible pump.

Waste water will be pumped to STP by way of relay from one


chopstick to another chopstick until to unit of Sewage Treatment
Plant.

Discharge planning system Sewerage and Water Used for buildings


using new and existing channel with dirty water systems, the
former accommodated while wearing Collection pit. The result of
the process of these system channeled to the parent Treatment
Sewage Plant / STP.The exhaust system with central / STP are
processed in sediment deposition and processed again into the
water up to lawn watering purposes, the contents of GWT water
hydrant.Kitchen or cafeteria to sewer is required to use grease
trap. Grease Trap appliance is installed under or next to the Sink.
The capacity is 25 gpm grease trap with grease retention capacity
of 50 lb. Intake of grease should be every day. Piping system
design dirty water, used water, venting is based on the
International Standard for plumbing.

c. Rain Water Planning

Rain gutter pipe will be calculated based on the Book of Plumbing


System. The intensity of the rainfall for the calculation of the
amount of rain gutters taken 200 mm / hour, a maximum of 300
mm / hour.
Rainwater from the roof of the building through the roof drain is
channeled by gravity through a standpipe or flat tube wells to
recharge and spills flowed into the sea.

4.2. Design System of Fire Fighting

300
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

For protecting building & occupant, the building shall be provided with
system of fire fighting.

Design system of fire fighting consist of :

a. System Hydrant & Sprinkler

b. System Fire Extinguisher

a. System Hydrant & Sprinkler

System of hydrant consist of Indoor Hydrant and Outdoor Hydrant.


Indoor Hydrant is equiped with Hydrant Box Indoor and Outdoor
Hydrant is equiped with Hydrant Pillar and Siamese Connection.

For saving cost and efficiency the system of fire fighting will be
designed with centralized system where the fire pump will be used
for all buildings and The fire pump system consist of 1 set fire
pump. Set of pumps will be placed in Pump House that located on
site area.

For Protecting building of Terminal and other buildings. main pipe


of Fire fighting from fire pump will be connected to all buildings.
Special For terminal building have 4 (four) connection and 4 (four)
riser pipe. Where for every riser pipe will servicing ground floor & 1
st floor. For every floor has some Hydrant Box Indoor that
connected from branch pipe of hydrant pipe riser. For other
buildings, main pipe of fire fighting connected to Hydrant Box
Outdoor only, that placed outside of the building. Beside Hydrant
System the Terminal building have sprinkler system, especially for
Terminal building . The riser pipe of sprinkler system will be
connected from riser pipe of fire fighting and also have 4 (four)
riser pipe. Where for every riser pipe will servicing ground floor & 1
st floor. For every floor has some sprinkler unit that connected
from branch pipe of sprinkler pipe riser. For every sprinkler riser
pipe will be equipped with Alam Check Vale & Alarm Gong. For
other buildings no need the sprinkler system. But special for
Building of ATC will be equipped with Fire Suppression system.

b. System Fire Extinguisher

System fire extinguisher consist of :

- Portable Fire Extinguisher

Each room of building must be provided with Portable Fire


Extinguisher.

Type of portable fire extinguisher depend on condition and


character of room that will be protected.

4.3. Design System of VAC

301
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

For pleasure of Passenger, and staff / Occupant in the building, all


chambers in the building will be equiped with the Ventilation and Air
Conditioning System.

System of VAC consist of :

a. System Air Conditioning


b. System Mechanic Ventilation
a. System Air Conditioning
For saving maintenance cost, the system of air conditioning shall
appropriate to this building, by using centralized system.

b. System Mechanic Ventilation


System mechanic ventilation is needed to waste the smell air,
dust, smoke etc. this system will be installed in chamber such as
: toilet, pantry, storage and some laboratory. The suction air will
be distributed through ducting and grille.

4.4. Design System of Transportation in The Building


For time efficiency of passenger / occupant, employee, the building will
be equipped with some Elevator / Escalator and Elevator especially for
disabled passenger.

13.3. Design Criteria


3.1. Plumbing
a. Design System Of Clean Water
1.Clean water necessity
Passenger : 15 liters/pax/day

Staff / employee : 100- 200 liters/person/day

Passenger : 500 pax

Staff / employee for all Buildings : 180 person

2.Stock of Clean Water Reservoir : (3) days


3.For designing flow of Clean water in the pipe shall be base on the load
of fixture units.

b. Design System of Waste Water / Soil Water


1.For designing flow of Waste Water / Soil water in the pipe shall be
base on the load of fixture units.

c. Sanitary Load
CW WW/SW
Lavatory : 2 1 FU

302
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Urinal : 5 4 FU

Closet

- Flush Tank : 4 3 FU

- Flush Valve : 10 8 FU

Sink : 4 3 FU

Janitor : 4 3 FU

3.2. Fire Fighting


a. Design System Of Hydrant
 Class of Fire : Light Hazard Classification
 Hydrant Box Indoor : Max. reach of Fire hose length is 30
m.
/1 HBI for every 500 – 800 m²
 Hydrant Pillar : Max. 60 m between each pillar
hydrant
 Capacity of Hydrant Pump : For the first standpipe shall be 500
Gpm and for additional standpipes
shall be 250 Gpm per standpipe

 Hydrant Pump Set Consist of : 1 unit Electric Fire Pump


1 unit Diesel Fire Pump

1 unit Fire Jockey Pump

 Standard of Hydrant Pump : NFPA 20/ULFM


 Residual Pressure : 6,9 bar at highest point
 Piping system : Wet & Loop System
 Time of Fire Fighting : + 60 minute
b. Design System of Sprinkler
Classifications light hazard
: classification
Covered Area 18 m²/sprinkler
: head according to
NFPA 13
c. Design System of Fire Extinguisher
a) The maximum distance between the utility should not be more than 15
meters except for the parking area to 15m maximum according to NFPA
10
b) Total utility area minimum 1 piece for 150 m² to 200 m² floor parking.
c) Utility type and capacity (18 liters of extinguishing agent for 500 m 2):
 Multi Purpose Dry Chemical 6 Kg for common areas
 Carbon Dioxide 6 Kg for Electrical/Mechanical/kitchen
 Carbon Dioxide 25 Kg mobile type for the generator room and the
engine room
d) Water storage for air plane firefighting to be estimated 100 m 3

303
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

3.3. Ventilation & Air Conditioning


3.1. Air Conditioning
A. General
Building usage data comply with Architect plans.

B. Basic Planning
Standards
 American Society of Heating, Ventilating and Air Conditioning
Engineers (ASHRAE)
 Sheet Metal and Air Conditioning National Association (SMACNA)

C. Oecusse Building Detail


 Outdoor and Indoor Design
Service Area Temperature Relative
Humidity
% RH

Outside Condition 35 70%

 PASSENGER TERMINAL 23 ± 2 55% ±5%


 METEORLOGY & ATC 24 ± 1 55% ±5%
 ATC TOWER 22 ± 2 50% ±5%
 MAIN POWER HOUSE 24 ± 1 55% ±5%
 GSE SHELTER 24 ± 1 55% ±5%
24 ± 1 55% ±5%
 CARGO TERMINAL
24 ± 1 55% ±5%
 RFFS BUILDING
24 ± 1 55% ±5%
 QUARANTINE BUILDING 24 ± 1 55% ±5%

 Outside air requirments per person = 15 CFM/Person – 20


CFM/Person

 Noise Criteria
Service Area Noise Criteria (dB)

 PASSENGER TERMINAL 30 – 35
 METEORLOGY & ATC 30 – 35
 MAIN POWER HOUSE 35 – 35
 GSE SHELTER 35 – 45
 CARGO TERMINAL 35 – 45
35 – 35
 RFFS BUILDING
30 – 35
 QUARANTINE BUILDING
30 – 35

D. Control Room Temperature


To set the indoor air automatically, it will use room thermostat
and settings manually through the fan speed control that can
be placed integral with broadest lighting panel.

304
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

E. Passenger Terminal Building


Air Conditioning System for buildings mentioned above are
proposed to be Air Cooled Chiller System with the following
consideration:
1. Air Cooled Chillerseasy for future additional and expansion.
2. Air Cooled Chiller is more suitable for larger buildings.

F. Main Power House, FRB Building, GSE Building, Cargo


and Quarantine Building
Proposed Air Conditioning System are following consideration:
1. Wall mounted is more efficient for smaller building.
2. Wall mounted air conditioning system is cheaper than any
other systems.
3. Support structure more light.

3.2. Mechanic Ventilation


Air change depend on the kind of room such as :

a. Pantry Room : Air Change = 6 – 10 x


b. Toilet Room : Air Change = 10 – 15 x
c. Storage Room : Air Change = 6 – 10 x
d. Pump Room : Air Change = 15 – 20 x

e. Panel Room : Air Change = 10 – 15 x

3.4. Transportation In The Building


For designing number of elevator shall comply to these criteria as follow
:

 Minimum handling capacity : 13 – 15 %


 Interval : 25 – 30 second

3.5. Sewage Treatment Plant


1.Type of STP : Biofiltration System.
2. Materials : Fiber Glass 450 kg/m2, Resin SHCP 220-BQTN,
5 mm thick, warranty 10 years.
3. Flow of process:
 Grease Trap.
 Equalizing Chamber
 Settler.
 Anaerobic Chamber.
 Aerobic Chamber, reduce BOD, COD and SS.
 HDCO Chamber, reduce BOD, COD, SS and ammonia.

305
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 Clarifier Chamber.
 Filtration Chamber.
 Discharge Disinfectant Chamber and Chlorination.
 Back Wash for Sludge by Air Blower.
4. Influent :
• BOD : 250 ppm.
• COD : 300 ppm,
• SS : 200 ppm
5. Effluent :
• BOD : 20 – 30 ppm.
• COD : 30 – 50 ppm,
• SS : 20 – 30 ppm
3.6. Explosion Signal Shall be Installed at
1. Fuel Station Area.
2. Sewage Treatment Plant

13.4. Engineering Calculation


4.1. Determining The Ground Reservoir Capacity
Terminal Building
Number of Passengers Assumptions
: 500 pax/day
Per Person / passenger : 15 liter
Assumptions : 500 pax/day x 15 ltr
: 7500ltr/day.
Number of Employee Assumptions
: 100 person/day
Per Person / employee : 150 liter
Assumptions : 100 pax/day x 150 ltr
: 15000 ltr/day.
F&B, restaurant, retail : 209 m2
Per m2 : 60 liter
Assumption : 209 m2 x 60 ltr/m2
: 12540 liter
Total needs of passengers and employees, retail
: 7500 + 15000 ltr+ 12540
: 35040ltr /day
: 35.04 m3/day.

Meteorology Office & ATC (Air Traffic Control)


Meteorology Office
Number of Employee : 20 person/day
Per Person / employee : 100 ltr
Assumptions : 20 person/day x 100 ltr

306
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

: 2000 ltr/day.
: 2 m3/day.

ATC
Number of Employee : 5 person/day
Per Person / employee : 200 ltr/day.
Assumptions : 5 person/day x 200 ltr
: 2000 ltr/day.
: 1 m3/day.

Main Power House


Number of Employee : 5 person/day
Per Person / employee : 200 ltr
Assumptions : 5 person/day x 200 ltr
: 1000 ltr/day.
: 1.0 m3/day.
Cargo Terminal
Number of Employee : 20 person/day
Per Person / employee : 100 ltr/day.
Assumptions : 20 person/day x 100 ltr
: 2000 ltr/day
: 2 m3/day.

FRB
Number of Employee : 15 person/day
Per Person / employee : 200 ltr/day
Assumptions : 15 person/day x 200 ltr
: 3000 ltr/day.
: 3 m3/day.

Quarantine Building
Per Person / employee : 5 person/day
: 100 ltr
Assumptions : 5 person/day x 100 ltr
: 500 ltr/day.
: 0.5 m3/day.

GSE Building
Number of Employee : 10 person/day.
Per Person / employee : 150 ltr/day.
Assumptions : 10 person/day x 150 ltr
: 1500 ltr/day.
: 1.5 m3/day

307
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Total Clean Water Requirement at OecusseAirport( VCW )


35.04+ 2 + 1 + 1 + 2 + 3 + 0.5+ 1.5 = 46.04 m³/day
Standby for 3 days, it will be = 138.12 m³/day
Safety Factor for cleaning
Building & Other is 20 % = 27.624 m³/day
Volume Clean Water ( VCW ) = 138.12 + 27.624 = 166 m3

Terminal Building have between three to four standpipes and then the
flow rate of fire pump will be = 1000 GPM
Volume of Fire Fighting (VFF) = (1000 GPMx3,785x60 minute)/1000
= 227m³

Total Volume of Ground Water Tank will be :


= VCW + VFF
= 166 + 227
= 393 m3

4.2. Determining Sewage Treatment Plant Capacity


At this complex has 3 (three) Sewage Treatment Plant :
1. 1 (one) unit for Passenger Terminal Building with capacity 30 m3/day.
2. 1 (one) unit for MPH, ATC&M, FR Building with capacity 6 m3/day.
3. 1 (one) unit for Cargo, Quarantine, GSE Building with capacity 4
m3/day.

4.3. Determining Elevator


1. Service Lift :
Capacity : 1000 kg
Type : Roomless
Opening : 3 Stop
Door Type : Single Door
Quantity : 1 Unit
2. Pasenger Lift
Capacity : 15 person
Type : Roomless
Opening : 2 Stop
Door Type : Double Door
Quantity : 2 Unit

308
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

309
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

310
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

311
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

312
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

13.5. Attachment

313
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

314
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

315
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

316
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

317
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

318
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

319
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

320
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

321
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

322
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

323
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

324
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

325
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

14. ELECTRICITY AND ELECTRONICS


14.1. ELECTRICITY
Medium Voltage Cable:
Indoor Use:
 Specification : IEC 60502
 Single/Multi Core Copper/Aluminum.
 XLPE Insulated, copper tape screen, PVC Sheathed.
 Operating Voltage: 20 kV (24kV).
Outdoor Use:
 Specification : IEC 60502
 Single/Multi Core Copper/Aluminum.
 XLPE Insulated, copper tape screen, Zinc-coated Flat Wires Steel Armored,
PVC Sheathed.
 Operating Voltage: 20 kV (24kV).

Transformer:
 Specification Standard: IEC 76, 144, 726.
 Service specification :
 Rating Voltage : 24 kV
 Primary Voltage : 20 kV, 3 phase 3 wire.
 Secondary Voltage : 231 – 400 V0lt, 3 phase 4 wire.
 Tap off changer : -5%, -2.5%, 0, +2.5%, +5%
 Vector Group : DYn-5.
 Frequency : 50 Hz.
 Breaking Power Cap. : 500 MVA at 20 kV.
 RH : 100 %
 Temperature : 40 °C.

Medium Voltage Cubicle:


 Specification Standard: IEC. 60298, 60427, 60466
 Service specification :
 Rating Voltage : 20/24 kV.
 Voltage test for 1 minute : 50 kV.
 Impulse Voltage : 125 kV
 Frequency : 50 Hz.
 Ampere rating : 630 A
 Max. short circuit power : 500 MVA
 Breaking capacity : 14.5 kA
 Circuit Breaker : Fixed type, LBS, VCB/SF6.
 Control System with auxiliary power supply by UPS, 60 minute
Back-up time.
 To provide spare double MV cable line feeder from MPH to the Terminal
Building(Next stage).

326
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 To provide spare space for 1 MV cubicle at MPH and 1 at Terminal Building,


with manual operation (Next Stage).

Low Voltage Cable :


Indoor Use:
 Standard specification : IEC 60502-1
 Copper core conductor.
 Single/Multi core
 PVC insulated and PVC sheathed.
 Voltage rating 0.6/1000 Volt.
Outdoor Use:
 Standard specification : IEC 60947, 61439
 Copper core conductor.
 Single/multi core
 PVC insulated and PVC sheathed, galvanized steel plate armored.
 Voltage rating 0.6/1000 Volt.

Low Voltage Panel.


 Standard specification : IEC.
 Voltage rating : 220/380 Volt, 3 phase, 4 wire.
 Frequency : 50 Hz.
 Temperature : 45 °C
 RH : 95 %.
 Voltage test : 3000 Volt.
 Box panel : Steel plate minimum 2 mm thickness.
 Component : ABB, Siemens, Schneider.
 Control System with auxiliary power supply by UPS, 60 minute
Back-up time.

Power Distribution System


Voltage drop: Allowable voltage drop from Main Power Distribution Board to the
end point of each electrical load = 5 %.

Motor Starting System

Power Capacity-Electro Motor Starting System with overload


protection

- up to 5 kw - DOL (Direct On Line)


- 5 kw - 25 kw - Start-Delta Starter
- 25 kw - more - Soft Starter

327
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Grounding resistance value:


 Electronic System maximum 1 Ohm.
 Equipment Grounding Electrical System max. 2 Ohm
 Lightning Arrester max. 5 Ohm.

Generator:
 Standard reference : VDE/DIN, IEC, NEMA.
 Diesel Fuel Engine
 Standby Power System.

Lighting System.
 Standard : IEC, IES.
 Cable connection code :
 Phase R : Red color
 Phase S : Yellow.
 Phase T : Black.
 Phase Neutral : Blue.
 Grounding Wire : Green/Yellow strip.

Standard luminance level:

328
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

14.2. Electronics
Electronic System consists of the following item:
1. Telephone/PABX
2. Internet Data Communication.
3. Fire Alarm.
4. Public Address.
5. Master Clock System.
6. FIDS
7. CCTV
8. IP-TV.
9. Access Control.
10. Building Automation System.
11. SCADA System

1. Telephone System.
System Telephone with digital IP PABX designed with the following feature:
b. PABX with software program for operational.
c. PABX with varies function and flexible feature.
d. PABX expandable with the maximum capacity.
e. PABX completed with the system "Call Detail Recording".
f. Extension line 150-200.
g. Trunk line 15-20.
h. Comply with International Standard: CCITT (Consultative Committee on
International Telegraph and Telephone).

Installation system with:


 Indoor and outdoor Telephone cable with Copper core.
 Or Fiber Optic cable.
2. Internet Data Communication :
 Cable data UTP cat.6, 4 pair.
 4 pair modular Jack RJ45.
 24 port category 6 Switch Hub.
 Set of PC and Printer, and Server to support Ethernet data operation.
3. Fire Alarm System :
 Main Control Fire Alarm (MCFA).
 Annunciator at Security Control Room and RFFS.
 Semi-addressable with maximum 5 loop.
Detector consists of the following:
 Fixed Temperature Detector
 Rise of Rate Temperature Detector.
 Smoke Detector.
 Manual Station: Break Glass, Telephone Outlet, Audio/Visual Alarm Bell.

329
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

Censor allocation:

DETECTOR
FIXED ROR
COMBINATION
TEMP. FIXED TEMP. SMOKE FLAME GAS

- Kitchen - Meeting Room - Control Room, - Ware House


with
- Parking Building Receptionist Flammable
Materials.
- Restaurant - Lobby

- Bed Room

- Genset and - Machine Room. - Control - Store Room


Transformer Room for with
Room. - Lift Room. Vital volatile
Installation. Gases
- Pump Room.

- Stairs

- Corridor

- Lobby

- Function Room

- Store Room

4. Public Address.
Intended for normal and emergency public Annunciator with the following
conditions:
 Background Music: Sound Pressure Level 5 – 40 dB, 20Hz-20 kHz.
 Normal announcement: Sound Pressure Level 40-60 dB, 200Hz-6/10 kHz.
 Emergency announcement: Sound Pressure Level 60-120dB, 10 kHz-20 kHz.
Equipment:
 Power Amplifier and Mixer Pre Amplifier
 Cassette Tape Deck, CD player and AM/FM Tuner.
 Microphone.
 Speaker: Ceiling Speaker, Column Speaker and Horn Speaker.
 Cable NYYHY 3 x 1.5 mm2, and FRC 3 x 1.5 mm2.

5. Master Clock
Synchronization of display time intended for Airport operation consist of the
followings:
 GPS with antenna.
 Master Clock Unit with redundant.

330
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 6-12 channel GPS receiver.


 Change Over Switch
 LCD Clock with multi-functiondisplay: City name, date and temperature.
 Analog Clock, accuracy +/- 50 ms (Synchronized).
 Cable data UTP cat.6.

6. Flight Information Display System (FIDS).


FIDS consist of the following main items:
 Computer Server with printer.
 Software.
 Switching Hub 24 port.
 Client PC.
 LCD TV Plasma 55 inch.
 Cable UTP cat. 6

7. CCTV System.
CCTV with IP Camera is part of the security equipment to the Airport operation
with the following item:
 Network Video Recorder (NVR)
 Storage capacity 5000 GB.
 Indoor Mini dome Fixed Camera.
 Pan Tilt Zoom Outdoor Camera wit Bracket.
 Video Management Software.
 Operator PC Client, Display Monitor, Operator Console.
 Distribution Switch and access switch.
 Cable UTP category 6 and accessories.

8. IP Television.
Airport Television Network for Airport operation usage with the following items :
 Streamer with IP-Interface, and Access.
 IP-Streamer Power Supply unit.
 Digital Signage IP-TV Server.
 Digital Signage Software Application.
 TV LCD with bracket.
 Outlet IP-TV
 Cable UTP category 6.

9. Access Control.
Access Door Control intended for security purposes at the restricted zone in
Airport Terminal Building and others, with the following main items :
 IP-Base Reader controller and reader interface.
 Access Control PC with HDD.
 Software application.

331
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 Set of Door Control: Card Reader, Proximity reader or Biometric reader,


locking devices and exit button, emergency break glass.
 Cable UTP category 6.

10. Building Automation System.


Purpose is mainly for control and monitoring of all connected Mechanical and
Electrical system installed to support Airport daily operation. Following are the
main item for BAS:
 Master Controller.
 Software BAS application.
 Server.
 PC Work station with Printer.
 Switch Hub 24 port.
 Remote Controller :
 Digital Input/output, Analog Input/output.
 Temperature sensor.
 KWH Transducer.
 Voltage transducer.
 Current censor.
 Pressure censor
 Relay.
 Cable UTP category 6.

11. SCADA.
Purpose is mainly for control and monitoring of all connected Electrical system
installed to support Airport daily operation. Following are the main item for
SCADA:
Main Power House :
 Master Controller.
 Server.
 PC Work station with Printer.
 Local Controller for:
 PLC Input/output point.
 TM Cubicle
 Transformer.
 Generator.
 UPS.
 VPMDP.
 CCR AFL
 Current censor.
 Relay.
 Cable UTP category 6.

Air Trafic Controller :


 Sub- Controller.
 PC Work station with Printer.
 Local Controller for :
 PLC Input/output point.

332
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 CCR AFL
 Tower Control Panel with Grafic.
 Current censor.
 Relay.
 Cable UTP category 6.
Kabel communication from Main Power House to ATC with fiber oftic cable,
12 core single mode.

Terminal Buiding :
 Sub- Controller.
 PC Work station with Printer.
 Local Controller for :
 PLC Input/output point.
 MV Cubicle Panel.
 Transformer.
 LVMDP
Kabel communication from Terminal Sus Station to Main Power House with fiber
oftic cable, 12 core single mode.

DVOR/DME :
 Sub- Controller.
 PC Work station with Printer.
 Local Controller :
 PLC Input/output point.
 MV Cubicle.
 Transformer.
 Generator.
 LVMDP
 Relay.
 Cable UTP category 6.
Kabel communication from DVOR/DME to MPH with fiber oftic cable,
12 core single mode.

333
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

15. FUEL DEPOT

Aviation fuel will have to be provided to aircraft operating into/from Oecussi International
Airport. These aircraft will range from medium to short haul passenger jetliners with the
occasional wide body long haul charter flight and it is assumed that general aviation
piston driven private aircraft may demand this airport mainly for business purpose.

Figure 1 Oe-cussi International Airport Layout

To cater for these needs, Oecussi International Airport requires that its Master Plan
contemplates the design and construction of an avation fuel depot, and designed to comply
with the best aviation standards in terms of safety and environment protection. The project
requirement is to service fuel aviation fuel consumption are as follow:

 Aviation fuel requirements

o Aircraft assumption :

 4 aircraft code C strands together at the same time

 2 aircraft code C and 1 code E strands at the same time

o General aviation (no feasible forecast)

o Helicopter : 2 aircraft considered on original scope

 Ground Support fuel requirements

o Ground Support aircraft tanker :

 minimum 4 tanker truck for 4 parking strands

o Ground Support Equipment (GSE) assumption :

 2 baggage/cargo tow tractor

 8 closed baggage carts

 1 aircraft pushback and tow tractor

 Jet engine air start unit

 2 cleaning service car

 1 lavatory service car

 1 ground power unit

334
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

 2 passenger stair truck

 4 caster bed pallet trailer

o Rescue & Fire Fighting Services (RFFS) assumption :

 2 fire fighting vehicles

 1 ambulance

 4x4 vehicle

The layout components requirements are assumed as preliminary as follow:

 Aviation fuel depot dedicated area – 600m2 (20m x 30m)

 Minimum storage 80,000 Litres of aviation Fuel Jet A-1 (ø3.8x7.1m)

 Minimum storage 3,000 Litres of AVGAS 100LL (ø2.28x1.4m)

 Adequate and dedicate pump, filter & water separate system

 Unloading area from refinery

 Loading area to aviation Fuel system & Ground Support Fuel

 Fire fighting system internal of Fuel Farm

 Offices (20m2)

 Control post (3m2)

 Landside access from security gate

 Perimeter fence

15.1 Process

There are two types of fuel processed in this fuel depot. The process of the both type
of fuel is completely separate, except in the waste handling process.

The process is carried out in the fuel depot is divided into two kinds :

1. Unloading system

Unloading system is the fuel dismantling system from truck container to the
storage tank, using an electric pump equipped with a filter.

2. Loading system.

Loading system is a system of charging truck fuel tank that will be sent to the
aircraft, using an electric pump and flow meter to measure the fuel number send
to the truck.

15.2 Safety Engineering

Fuel farm depot is at Oecusse International Airport are intended to continuously


receive Avtur and Avgas. Personnel safety shall be the primary consideration in
planning and arranging the fuel farm depot facilities. Designs and protective measures

335
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

shall account for all phases of operations, including temporary situations. Accordingly,
the fuel farm depot area facilities shall be designed and equipped to

a. Prevent leak, fire, explosion and any possible hazard.


b. Minimize the effects of leaks, fire or explosion in order to preclude hazard
progression, and
c. Conduct effective fire fighting operations without personal exposure to extreme
danger, and
d. Provide for safe evacuation from the worst case scenario.

15.3 Mechanical

To ensure the system reliability, both unloading pump and loading pump are provided
with 2 x 100% capacity mode, which only one pump will work while other is stand-by.

Fuel depot is equipped with 2 x 40,000 L horizontal type Avtur Storage tank and 1 x
3,000 L vertical type Avgas Storage Tank.

15.4 Piping Engineering

Piping system set up on the fuel unloading system and fuel loading systems either on
Avtur line or Avgas lines.

Line sizing is done to calculate the size of the pipe with considering the limits of speed
and pressure drop.

A series of valve is installed in Avtur Line to direct the flow of fuel to the particular
tank.

15.5 Electrical Engineering

Electrical power lines are fully buried excepted residential and indoor purpose. Local or
national electrical safety codes and other publications set in detail the special
precaution needed to safeguard against the risk of fire or explosion due to the use of
electrical current and lightning. The total conductivity of the earth conductors / power
supply conductor shall meet the requirements of the National Electrical Code (NEC).

For in hazardous area, the basis for area classifications shall be the recommended
practices outline in API RP 500 and the electrical equipment and wiring materials shall
conform to the requirements of NEC Article 500.

Every equipment such as tanks and the depot component should always effectively
earthed included any control distribution panel in accordance with the detail
recommendation for earthing given in nation standard. A bonding cable should be
attached to the vehicle bonding point before the loading hoses are connected. The
earthing system resistance to earth shall not exceed 5 ohms. System earthing shall be
solidly grounded at 380 V systems.

15.6 Instrument / Control Engineering

The Instrument control system and monitoring system will be operated manually
which the system will manage into Receiving area, Storage, and Distribution.

336
NEW DEVELOPMENT OF OECUSSE AIRPORT
DESIGN NOTES
Revision 02, Date : 16/09/2016

The Instrument specifications to be used in the system are;

a. Flow metering (PD Meter)

b. Breather Valve

c. Pressure Gauge and Differential Pressure Gauge

d. Level Gauge and Level Switch

e. Restriction Orifice Plates

f. Limit Switches

g. Spill Oil Detector

h. Fire Alarm System (FAS)

337