You are on page 1of 1

LANDSCAPE DESIGN CONSULTANT:

TI-21

WL.-0.35
BL.-0.425

258/Ter Dien Bien Phu Street, Ward 7, District 3, Ho Chi Minh City, Vietnam

60
Tel: +84 8 6281 9690

150
www.landsculptorstudio.com

90
PROJECT :
300 300 300 300 100 500 100

EMPIRE CITY
ST-05 ST-05 TILIA RESIDENCE (MU7)

900

900
THU THIEM, DISTRICT 2, HO CHI MINH CITY, VIETNAM
FL.-0.25 FL.-0.25
GLASS BALUSTRADE, SITE PLAN :
TO ARCH
1B

N
50MM x 5MM THK.
200 300 300 200 200 1000 300 300 300 300 100 500 100
STAINLESS STEEL BAR
LED LIGHT @250MM SPACING
60 140 ST-05 PAV2
TI-21 TW.-0.25 FL.-0.25 FL.-0.25

50

50
75 40 60
75 40 60

150
TW.-0.35 A1

125
4530
ST-05 A2

150
PARAPET ,TO ARCH ST-05

350
A3
PB-01

550

150
TC.-0.65
ST-05

150
ST-06
TW.-0.25 A1 FL.-0.85 CLIENT :
TW.-0.35 TW.-0.30
A2 EMPIRE CITY LLC.
LE MERIDIEN BUILDING, 3C TON DUC THANG STREET
A3 UNITS 3&4, 8TH FLOOR
PB-01 ST-06 ST-05 TI-21 PAV2
BEN NGHE WARD, DISTRICT 1
HO CHI MINH CITY, VIETNAM
TC.-0.65 FL.-0.85 WL.-0.35 FL.-0.25 +84 8 3923 9303
BL.-0.425 C1
FG.-0.70
APPROVAL OF THE OWNER: General Director
4950

LOCAL ARCHITECT :
3000

B+H Architects
50MM x 5MM THK. 6th Floor, Resco Tower, 94 - 96 Nguyen Du Street, Dist. 1, Ho Chi Minh City, Vietnam, 70000
STAINLESS STEEL BAR T/8.38.22.4497 F/8.3822.4498
@250MM SPACING
STRUCTURE ENGINEER CONSULTANT :

ARUP
SUNKEN LOUNGE 'A' - SECTION 1
1B SCALE 1:15 AT A1 FORMAT
50MM x 5MM THK.
2400 STAINLESS STEEL BAR MEP ENGINEER CONSULTANT :
@250MM SPACING
200 300 300 200 60 90 1350 750 90 60 700
ARUP

1C ISSUED FOR
GLASS BALUSTRADE,
TO ARCH SCHEMATIC DESIGN
NOT FOR
FOR DESIGN DEVELOPMENT
150 50MM x 5MM THK. CONSTRUCTION

250
STAINLESS STEEL BAR FOR TENDER
700 200 700 1300 200 200 300 300 200
@250MM SPACING
20
PAV2 60 140 140 60
FOR CONSTRUCTION
FL.-0.25 TW.-0.25
REVISION

50

50

75 40 60
75 40 60
250
LED LIGHT TI-21
A1 WL.-0.35 TW.-0.35
TI-21 NO. DATE DESCRIPTION

45 30
ST-05
BL.-0.425

350
A2 0 SEP 2018 DESIGN DEVELOPMENT

300
ST-05
PARAPET ,TO ARCH

350
ST-05
240
A3

550
PB-01
TC.-0.65

250
ST-06
250

FL.-0.85
750

A1

A2
250

A3
90

250

B1
60

TW.-0.25 TW.-0.30
ON NO ACCOUNT MAY THIS DRAWING BE SCALED.
ANY DISCREPANCY IN FIGURED DIMENSIONS (OR OTHERWISE DISCREPANCIES
BETWEEN ARCHITECTURAL/STRUCTURAL AND MECHCANICAL/ELECTRICAL
DRAWINGS) IS TO BE REPORTED IMMEDIATELY TO THE ARCHITECTS BEFORE
COMMENCEMENT OF WORKS.
CONTRACTORS MUST CHECK ALL DIMENSIONS FROM SITE.

AREA NOT UNDER LANDSCAPE PACKAGE

SUNKEN LOUNGE 'A' - DETAILS PLAN SUNKEN LOUNGE 'A' - SECTION 2


1A SCALE 1:15 AT A1 FORMAT 1C SCALE 1:15 AT A1 FORMAT
AREA NOT UNDER LANDSCAPE PACKAGE

NOTES: ALL STRUCTURAL, WATERPROOFING AND M&E SERVICES SHALL REFER


TO ARCHITECT'S AND ENGINEER'S DETAILS

Director Mahitti Wongruchatanun

Mahitti Wongruchatanun
Designed by
Nguyen Anh Hoang

Drawn by Do Minh Dang


MATERIAL & FINISHES LEGEND:
SEE DWG. LS-214X MATERIAL & FINISHES PLAN Checked by Piti Lerthattasil
LEGEND: SWIMMING POOL AND WATER FEATURE: OTHERS:
LANDSCAPE DRAWINGS
CEMENT MORTAR / CEMENT SCREED, DISCHARGE PIPE TO SWIMMING POOL 300MM(W) x 30MM THK ABS
A1 A9 GEO-TEXTILE FILTER FABRIC C1 ABS
SLOPE TO DRAIN BALANCING TANK, TO SPECIALIST GRATES, SPACING AT 25MM Drawing title :
WATER PROOFING MEMBRANE, JACUZZI AERATE JET NOZZLES AND PIPES, REFER NATURAL RIVER WASHED PEBBLE, SIZE AS SHOWN
A2 A10 SAND SETTING BED C2 PB
TO SWIMMING POOL SPECIALIST IN LANDSCAPE LAYOUT, TO BE SELECTED BY LA.

RC. STRUCTURE, REFER TO WATER INLET FROM BALANCING TANK, WATER 300x3MM THK. STAINLESS STEEL PLATE WITH S/S
A3
STRUCTURAL DWGS,
A11 CONTRACTION JOINT WITH CLEAR PVC DIVIDER C3
FEATURE PUMP AND FILTRATION TANK, TO SPECIALIST
SSP
STAKES @300MM SPACING LEVEL 2 - SWIMMING POOL ZONE
A4
RC. FOUNDATION, REFER TO
A12 STAINLESS STEEL DOWEL BAR C4
DISCHARGE PIPE TO WATER FEATURE SUNKEN LOUNGE 'A' DETAILS
STRUCTURAL DWGS, PUMP AND FILTRATION, TO SPECIALIST

COMPACTED SUB-BASE, REFER OVERFLOW DISCHARGE PIPE TO NEAREST DRAIN,


A5 A13 STYROFOAM C5
TO STRUCTURAL DWGS TO SPECIALIST

COMPACTED SUB-GRADE, REFER DRAINAGE DISCHARGE PIPE TO NEAREST PUMP AND FILTRATION SYSTEM, REFER TO WATER
Drawing No. :
A6 B1 C6
TO STRUCTURAL DWGS DRAIN, REFER TO MEP DWGS, TO SPECIALIST FEATURE SPECIALIST, TO SPECIALIST

WATER SUPPLY FROM DOMESTIC WATER SUPPLY WATER FEATURE BUBBLER JET NOZZLES, REFER TO LS-2371
A7 PLANTING MEDIUM B2 C7
SYSTEM, REFER TO MEP DWGS, TO SPECIALIST WATER FEATURE SPECIALIST, TO SPECIALIST

A8 SUBSOIL DRAINAGE CELLS B3


LIGHTING FIXTURE, REFER TO Scale : Date : REV.
LIGHTING PLAN
VARIES 18 SEPTEMBER 2018 0

You might also like