0 for Evita XL
D-9286-2009
Software 7.0 facilitates clinical routine Lock of I:E ratio
with new workflow support functions. In the past, in order to keep the
Further enhancements in the user inter- I:E ratio constant, it was necessary to
face help to increase patient safety. sequentially adjust the settings f and Tinsp .
With SW 7.0, the button “I:E constant”
SIMPLIFIES CLINICAL APPLICATION links these two parameters. If one para-
– Inspiratory termination [%PIF] meter is changed, the other is adapted
– Lock of the I:E ratio simultaneously to maintain a constant I:E
– QuickSet and PressureLink ratio. This new functionality facilitates
D-9287-2009
New monitoring parameters: HELPS TO INCREASE PATIENT SAFETY DESIGNED FOR THE FUTURE
Taue and ftrig SW 7.0 for Evita XL offers better visualiza- SW 7.0 is designed to meet upcoming
With the expiratory time constant (Taue) tion of curves and parameters due IEC standards and EN/ ISO norms like
90 66 166 | 09.10-3 | Marketing Communications | LSL | LE | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2010 Drägerwerk AG & Co. KGaA
you can calculate the minimal expiration to more saturated colors and a higher the new Alarm Silence symbol
time that is required for a full exhalation. contrast. An improved large yellow and alarm priority information.
It helps to prevent ventilator induced Standby message is a clear indicator
PEEPi as long as a minimal expiration of 4- to the user that the ventilator is in the Be prepared for the future with SW 7.0
5 x Taue is assured. The time is given Standby mode. on your Evita XL, incorporating state-of-
in [msec] and measured after 63 % of the the-art technology and complying to
volume that has been exhaled. the latest clinical standards.
Online help texts support decision
The value (ftrig) displays the amount making in case of an alarm or warning
of triggered breaths per minute. It is a valu- message. The help texts are displayed in
able indicator about the patient’s sponta- the same hierarchical order as the alarms
neous breathing activity and helps to and have a clear structure of fault, cause
decide whether the patient can be extubat- and remedy.
ed.
SUPPORTS OPERATIONAL EFFICIENCY
Oxygen therapy The new Options Overview page in the
With SW 7.0, „Oxygen therapy“ is now System Setup menu shows all installed
a standard function in the Evita XL, options. It helps the efficient use of your
providing accurate oxygen flow therapy ventilation fleet. Know the full capacity of
via mask or nasal prong. The availability your Evita XL and have the right optional
of invasive and non-invasive ventilation functionality at the bedside when you
together with oxygen therapy in one need it.
device, helps to improve workflow.
HEADQUARTERS REGION EUROPE CENTRAL REGION MIDDLE EAST, AFRICA, REGION NORTH AMERICA
Drägerwerk AG & Co. KGaA AND EUROPE NORTH CENTRAL AND SOUTH AMERICA Draeger Medical, Inc.
Moislinger Allee 53–55 Dräger Medical GmbH Dräger Medical GmbH 3135 Quarry Road
23558 Lübeck, Germany Moislinger Allee 53–55 Branch Office Dubai Telford, PA 18969-1042, USA
23558 Lübeck, Germany Dubai Healthcare City, P.O. Box 505108 Tel +1 215 721 5400
www.draeger.com Tel +49 451 882 0 Dubai, United Arab Emirates Toll-free +1 800 437 2437
Fax +49 451 882 2080 Tel + 971 436 24 762 Fax +1 215 723 5935
info@draeger.com Fax + 971 436 24 761 info.usa@draeger.com
contactuae@draeger.com