Option Volume Ventilation

Infinity® Acute Care System™ – Dräger Babylog® VN500:


Combining the benefits of Volume Guarantee ventilation (VG)
with the enhanced safety of Mandatory Minute Ventilation
(PC-MMV), the Volume Ventilation option for the Babylog® VN500
ventilation unit is the most advanced volume ventilation tool for
neonatal respiratory care Dräger has ever developed.

D-21965-2009
NEW VOLUME GUARANTEE variation in respiratory drive and other
FUNCTIONALITY parameters, often on a breath-to-breath
– Volume Guarantee ventilation is used basis. Surfactant therapy can have a rapid
as an adjunct to the Pressure Control and profound impact on compliance
(PC-) CMV, SIMV, A/C and PSV values.1 Assuring the accurate delivery of
modes, providing accurate tidal volume tidal volumes during changes in
control for these pressure-controlled compliance, resistance and leak volumes
modes. is a technically challenging prospect, but
– Our highly advanced PC-MMV/VG one that’s well worth the effort. Scientific
mode functions much like PC-SIMV documentation have shown that strategies
with Volume Guarantee continuously utilizing Volume Guarantee can significantly
D-19538-2009

regulates the rate of mandatory cycles lower mean airway pressures and avoid
to maintain a minimum set minute potential risks such as overdistension,
volume. barotrauma and hypocarbia.2 The goal is
– Volume Guarantee can also be used in not just to provide guaranteed tidal The Babylog® VN500 with Infinity®
conjunction with the High Frequency volumes, but to ventilate in harmony with Medical Cockpit™ C500
Oscillation (PC-HFO/VG) option to the baby. So Dräger has now combined
automatically regulate the pressure the tidal volume-based advantages of
amplitude required to maintain the Volume Guarantee (VG) with a new
set tidal volume during high-frequency minute volume based mode – Mandatory
ventilation. Minute Ventilation (PC-MMV). The result
– Our new Spontaneous CPAP mode is enhanced synchrony, a reduction of
with Volume Support (SPN-CPAP/VS) mean airway pressures and a more
regulates Pressure Support to main- comfortable infant.3
tain tidal volumes during spontaneous
breathing. THE FOREFRONT OF VOLUME
GUARANTEE TECHNOLOGY – MMV
VOLUME GUARANTEE – THE GOLD The Dräger Mandatory Minute Volume
STANDARD IN NEONATAL VENTILATION (PC-MMV) mode is based on conventional
Respiratory regulation in premature pressure-controlled synchronized
neonates can sometimes be erratic. These intermittent mandatory ventilation. By
babies frequently demonstrate substantial continuously analyzing volume and flow
02 | OPTION: VOLUME VENTILATION

90 66 364 | 15.06-3 | Communications & Sales Marketing | PP | PR | LE | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2015 Drägerwerk AG & Co. KGaA
rates including changes in resistance and CPAP WITH VOLUME SUPPORT 4. A Crossover analysis of mandatory minute
compliance, this mode maintains a (SPN-CPAP/VS) ventilation compared to synchronized
minimum set minute volume by adjusting The Babylog VN500 Volume Ventilation intermittent mandatory ventilation in
the mandatory cycle frequency. This mode option also allows you the ability to neonates, Guthrie SO, Lynn C, LaFleur BJ,
includes integrated apnea ventilation, and regulate Pressure Support in infants Donn SM, Walsh WF: Journal of
Pressure Support can be provided to help breathing spontaneously to achieve target Perinatology, 2005 25:643-646.
support spontaneous breathing efforts tidal volumes.
between mandatory cycles. In neonates
with erratic respiratory drive and regulation, Volume Guarantee has been integrated
this sophisticated Volume Guarantee into protocols around the world. Benefits
solution results in improved synchrony are documented not only on a scientific
and more stable blood gas concentrations. level but from patient and practitioner
Excessive inflation is rapidly recognized feedback responsible for delivering care.
and corrected, helping to avoid It’s those experiences that drive us to

D-2520-2010
complications such as pneumothorax. provide even the smallest patients with
When combined, scientific evidence innovative tools and relevant technology.
Volume Guarantee allows tidal volume control in
suggest that these benefits can
pressure limited ventilation.
significantly reduce ventilation related References
time.3 1. Reduction in lung injury after combined
surfactant and high frequency ventilation,
HIGH FREQUENCY OSCILLATION JC Jackson, WE Truog, et al, American
OPTION USING VOLUME GUARANTEE Journal of Respiratory Critical Care
This unique feature, available in Medicine, August; 150(2):253-9, 1994.
conjunction with the High Frequency
Oscillation option for the Babylog VN500, 2. High-Frequency Oscillatory Ventilation
maintains stable minute volumes in the
D-2521-2010
versus conventional mechanical ventilation
HFO mode. By continuously regulating for very-low-birth-weight-infants, Sherry
the oscillation amplitude, PC-HFO/VG Courtney, M.D., et al. New England Journal
During PC-MMV a minimum minute ventilation
compensates for dynamic changes in both of Medicine, Volume 347, No 9, 2002. can be set.
the lung and the breathing circuit. Blood
gases are again less subject to variation 3. Computer-controlled minute ventilation in
and complications associated with preterm infants undergoing mechanical
uncontrolled hyperventilation, such as ventilation, Claure N, Gerhardt T, Hummler
periventricular leucomalacia (PVL), can H, Everett R, Bancalari E: Journal of
be avoided.4 pediatrics, Volume 131, Number 6, 1997.

CORPORATE HEADQUARTERS REGION EUROPE CENTRAL REGION MIDDLE EAST, AFRICA REGION CENTRAL
Drägerwerk AG & Co. KGaA AND EUROPE NORTH Drägerwerk AG & Co. KGaA AND SOUTH AMERICA
Moislinger Allee 53–55 Drägerwerk AG & Co. KGaA Branch Office Dräger Panama Comercial
23558 Lübeck, Germany Moislinger Allee 53–55 P.O. Box 505108 S. de R.L.
23558 Lübeck, Germany Dubai, United Arab Emirates Complejo Business Park,
www.draeger.com Tel +49 451 882 0 Tel +971 4 4294 600 V tower, 10th floor
Fax +49 451 882 2080 Fax +971 4 4294 699 Panama City
info@draeger.com contactuae@draeger.com Tel +507 377 9100
Fax +507 377 9130
Manufacturer: REGION EUROPE SOUTH REGION ASIA / PACIFIC contactcsa@draeger.com
Drägerwerk AG & Co. KGaA Dräger Médical S.A.S. Draeger Medical
Moislinger Allee 53–55 Parc de Haute Technologie South East Asia Pte Ltd.
23558 Lübeck, Germany d’Antony 2 25 International Business Park
25, rue Georges Besse #04-27/29 German Centre
92182 Antony Cedex, France Singapore 609916, Singapore
Tel +33 1 46 11 56 00 Tel +65 6572 4388
Fax +33 1 40 96 97 20 Fax +65 6572 4399
dlmfr-contact@draeger.com asia.pacific@draeger.com

Locate your Regional Sales


Representative at:
www.draeger.com/contact

You might also like