You are on page 1of 4

** WIND LOAD EVALUATION AS PER IS802 ON LONGITUDINAL FACE OF TOWER

* WIND PRESSURE EVALUATION


- Basic wind Speed (Zone : 2) Vb = 39.00 m/s Fig. 1 [IS802( Part 1/Sec 1 ) :1995]
- Risk Coefficient (Reliability Level 2 and Zone 2) K1 = 1.10 Tb 2 [IS802( Part 1/Sec 1 ) :1995]
- Terrain Roughness coefficient Category-2 K2 = 1.00 Tb 3 [IS802( Part 1/Sec 1 ) :1995]
- Meterological reference wind speed Vr = Vb/1.375 = 28.36 m/s Cl 8.2 [IS802( Part 1/Sec 1 ) :1995]
- Design wind speed Vd = Vr.K1.K2 = 31.20 m/s Cl 8.3 [IS802( Part 1/Sec 1 ) :1995]
2
- Design wind pressure Pd = 0.6Vd2/9.81 = 1.50 kn/m Cl 8.4 [IS802( Part 1/Sec 1 ) :1995]

- Gross Areas are calculated as height of segment x Average width of panel and same has been used to evaluate wind load.
- Solidity ratio is calculated for actual sizes of members and force coefficient is for actual solidity ratio
and same is used for wind load calculation.
- Force Coefficients as per IS802 for 4 legged tower structure is considered
- Wind Load = Net Exposed Area x Drag Coefficient x Design wind Pressure x Gust Factor
- Wind Load at given level = 50 % load from panel above + 50 % load from panel below.
- In TABLE - 1 Net area and gross area is calculated
- In TABLE - 2 the design wind pressure has been calculated as per IS802 and wind load on panels are calculated
using the above mentioned formula.
- In TABLE - 3 the wind perpendicular to the Longitudinal face has been calculated at various levels as per above mentioned note
and are distributed equally on each node.
EVALUATION OF WIND LOAD - TABLE 1

Segment Height of Segment Top Width of Net Area Gross Area


No. from Segments Levels Segment of Parts of Parts
Top (meters) (meters) (meters) (metres2) (metres2)

PA1 1.00 21.00 0.000 0.371 0.750


PB1 1.00 20.00 1.500 0.922 1.500

INTENTIONALLY LEFT BLANK

INTENTIONALLY LEFT BLANK

INTENTIONALLY LEFT BLANK


PC1 1.00 19.00 1.500 0.922 1.500
PC2 1.00 18.00 1.500 0.922 1.500
PC3 1.00 17.00 1.500 0.922 1.500
PC4 2.00 16.00 1.500 2.342 3.500
PC5 2.00 14.00 2.000 1.618 4.500
PC6 6.00 12.00 2.500 3.353 19.500
PC7 6.00 6.00 4.000 4.752 12.000
EVALUATION OF WIND LOAD - TABLE 2

Segment Height of Segment Top Design Net Gust Cdt Wind Load
No. from Segments Levels Pressure Area response A x Pd x Cdt x Gt
Top (meters) (meters) (kN/meter2) (metres2) factor "Gt" (kN)

PA1 1.000 21.000 1.500 0.371 2.210 2.011 0.56


PB1 1.000 20.000 1.500 0.922 2.200 2.000 1.38

INTENTIONALLY LEFT BLANK


PC1 1.000 19.000 1.500 0.922 2.190 2.000 1.38
PC2 1.000 18.000 1.500 0.922 2.180 2.000 1.38
PC3 1.000 17.000 1.500 0.922 2.170 2.000 3.89
PC4 2.000 16.000 1.500 2.342 2.160 2.000 3.51
PC5 2.000 14.000 1.500 1.618 2.140 2.322 2.43
PC6 6.000 12.000 1.500 3.353 2.120 3.040 5.03
PC7 6.000 6.000 1.500 4.752 1.920 2.212 7.13
EVALUATION OF WIND LOAD ON TOWER - TABLE 3

Segment Height of Segment Top Wind Load Distribution Height of Moment Load Load
No. from Segments Levels of Wind Load Application Force x Ht. Left Right
Top (meters) (meters) (kg) (kg) (meters) (kg - meters) (kg) (kg)

PA1 1.000 21.000 0.556 0.278 21.000 126.000 3.0 3.000


PB1 1.000 20.000 1.382 0.969 20.000 120.000 3.0 3.000
PC1 1.000 19.000 1.382 1.382 19.000 114.000 3.0 3.000
PC2 1.000 18.000 1.382 1.382 18.000 108.000 3.0 3.000
PC3 1.000 17.000 3.890 2.636 17.000 102.000 3.0 3.000
PC4 2.000 16.000 3.512 3.701 16.000 96.000 3.0 3.000
PC5 2.000 14.000 2.426 2.969 14.000 84.000 3.0 3.000
PC6 6.000 12.000 5.029 3.728 12.000 72.000 3.0 3.000
PC7 6.000 6.000 7.129 6.079 6.000 72.000 6.0 6.000

26.69 23.12 894.00 30.0 30.00