You are on page 1of 1

Sound Insulation Prediction (v9 .0.

5)
Program copyright Marshall Day Acoustics 2017

- Key No. 3534


Margin of error is generally within Rw +/- 3 dB
Job Name: SE C H E AD Q U ART E R - RIY ADH
Job No.: P-13B W O O D PART IT IO N Page No.: 1 Notes: C onsiderable Flank ing Path
Date: 28 August 17 Initials:Khalid A. All Joints, G aps and Penetrations
File Name: insul Shall be acoustically treated

Rw 42 dB
D nTw 43 dB

ISO

STC 41
64 mm
100.0 mm O ITC 26
System description
Panel 1 : 1 x 18.0 mm Medium Density Fibre Board (ρ:700 kg/m3,E:3.3GPa,η:0.03)
AST M
Cavity: Steel stud (25g): Stud spacing 600 mm , Infill fibreglass (24kg/m3) Thickness 50 mm (ρ:22 kg/m3, Rf:8610 Pa.s/m2 )
Panel 2 + 1 x 18.0 mm Medium Density Fibre Board (ρ:700 kg/m3,E:3.3GPa,η:0.03)

Mass-air-mass resonant frequency =81 Hz

Panel Size 2.7x 4 m; Mass 26.3 kg/m2

frequency (Hz) R(dB) R(dB)


50 18
63 18 16
80 14
100 15
125 21 18
160 27
200 33
250 38 36
315 42
400 46
500 49 48
630 52
800 54
1000 55 55
1250 55
1600 51
2000 53 53
2500 58
3150 62
4000 66 65
5000 70

You might also like