Vers.47
4
GSM-Control
SMS text message software for PC
• Makes a PC as SMS text message server
• SMS sending/receiving with mobile phones and any devices with
GSM/GPRS-modem
• New interface with Wonderware Application Server Galaxy database
Reference
The GSM-Control runs on a PC and accesses sage communications and DDE/OPC/SQL/ Woikoski gas distribution
operator interface applications or directly MXAccess data exchange on the basis on
field devices by using DDE, OPC or MXAccess information prepared by GSMCFG. These
interfaces. GSM-Control also supports the two application programs are completely
reading/writing of data from/to SQL data- independent, i.e. each can work separately
bases. The remote control is based on GSM and doesn’t need another program to be
SMS text messages two-direction commu- started. The data prepared by GSMCFG is
nication, where GSM-modem (e.g. Siemens saved in GSM-Control configuration file - XML
MC35iT) is connected to the computer’s (eXtensible Markup Language) format file
standard (RS-232) serial port and GSM cel- used as an input file for GSMCTRL program.
• distribution of industrial and hospital
lular phone (remote GSM phone) is used by As many GSM-Control configuration files can gas tanks and gas bottles, monitoring
remote operator(s). Also the communication be created as necessary. of stations
• GSM-modem and SMS sw installed
GSM-Control reports all
into stations’ automation systems
events and communica-
• vehicle and service field personnel us-
tion traffic as well as
ing phones as HMI
result of GSM-modem
• fast responces, information to correct
initialization
persons considering work shifts etc.
Basically, the data exchange through the correspondingly configured SMS
GSM-Control can be initiated both from text message (possibly containing Reference
GSM and MS Windows environments: also some data obtained via DDE,
1. F
rom GSM environment - by send-
OPC or SQL or MXAccess) to remote Otis
ing SMS message to GSM-Control,
GSM operator or device linked to wireless elevator
this alarm or event condition. The
where the received message is
receiver of such SMS text message
maintenance
checked and processed according
can respond to GSM-Control – for ex-
the GSM-Control current con-
ample, send some acknowledgment
figuration. The received SMS text
SMS message possibly containing
message can contain some data to
some data for delivery via DDE, OPC,
be transferred via DDE, OPC, SQL
SQL or MXAccess.
or MXAccess from GSM-Control to
other MS Windows applications Moreover, it is possible to send (manual-
(e.g. to PC operator interface appli- ly or automatically through DDE, OPC or
cations or field devices through ap- MXAccess) any pre-configured text mes-
propriate communication servers) sage (“standard 1-way messages”) from
or databases. This SMS message GSM-Control to remote GSM operator or
received can have the correspond- device. The SMS text messages also can Otis uses the GSM-Control software,
ing response message configured be received from any (not configured) to deal with orders for spare parts
(also possibly containing data phone number (so called “ANYUSER” automatically and wirelessly, directly
between the service personnel’s
values obtained by via DDE, OPC, feature) and correspondingly replied mobile phones and the computer in
SQL or MXAccess) – in this case with information depending on contents Finland.
GSM-Control will respond with SMS of received message. Wireless service system minimizes
text message to the sender. response times and brings the
The GSM-Control can be used on In-
service, on the service personnel’s
2. F
rom MS Windows environment - ternet - it is possible to send SMS text mobile phones.
when some alarm or event occurs messages by e-mails from GSM-Control
in MS Windows application (e.g. in to GSM network and to receive SMS text
PC operator interface application messages as e-mails from GSM network.
or directly in the field device) and In this case GSM-Control may run without
the corresponding alarm or event GSM-modem connected – modem is Reference
condition is specified in GSM-Control. replaced by e-mail connection.
In this case GSM-Control will send ABB
Energy Systems
made wireless
• customer applications
• Excel, SQL etc.
• SCADA etc.
• info systems
GSM-Control software
SMS
• user interfaces text messages
• PCs, PDAs
• phones
SMS
text messages PC with GSM modem ABB Energiesysteme manufactures
SMS cogeneration energy systems 100
text messages
kW - 20 MW driven by gas engines,
gas turbines and fuel cells.
To allow operators and mainte-
nance personnel to have wireless
• devices with GSM-modems access via their mobile phones
• automation, PLCs
into the energy systems, ABB is
• service automates
using GSM-Control text message
software.
The GSM-Control may be accessed by The GSM-Control has extended functions
any Microsoft Windows (9x, NT, 2000, and support for Wonderware InTouch
XP) program working as a DDE or OPC (for MMI), IAS (Industrial Application
Ordering
Server (or DDE or OPC Client in case of Server, via MXAccess) and for I/O Serv- information
direct sending/receiving of SMS text ers (for field interfacing) developed with
messages via GSM-Control). Wonderware I/O Servers Development
Toolkit.
Hardware Kit:
GSM/GPRS-modem,
antenna, power supply,
modem cable to interface
PC to GSM network
PC GSM SET
Klinkmann_GSM_Control_en_0112.pdf