Professional Documents
Culture Documents
TEKNOWARE 4
CENTRAL MONITORING 41
CONTENTS 152
TEKNOWARE OY
Teknoware Oy is an international There are more than 350 employees
electronics company located in Lahti, at Teknoware. Both electronic and
mechanical components are engineered and
Finland. We design and manufacture manufactured in our factory in Lahti, Finland.
LED-based vehicle interior lighting Also our sales unit is located in Lahti. In
addition to partners operating in more than
systems and emergency lighting systems 20 countries around the world, we have sales
for buildings and ships. We employ units in the United Arab Emirates, the USA
and Spain.
approximately 350 people. We have
production facilities in Lahti and in
Connecticut, in the United States. We
export our products to more than 50
countries.
Worldwide
e
xpertis
s h Lighting E
ware - Finni
Tekno
TEKNOWARE IN 2013
4
Teknoware Emergency Lighting Product Catalogue_T375
TOUR OF THE TEKNOWARE FACTORIES IN LAHTI
5
Teknoware Emergency Lighting Product Catalogue_T375
EMERGENCY LIGHTING SYSTEMS
Teknoware offers a complete range of REMOTE MONITORING SYSTEMS the types of central battery units fulfill the
emergency lighting products, based on requirements of the standard EN 50171.
Teknoware offers a comprehensive
the following three main categories: In addition we offer several options
range of alternatives for the effective
1. central battery systems making the controlling, monitoring and
centralized monitoring of the
servicing easier.
2. self-contained luminaires using a emergency lighting. Central monitoring
traditional battery is available for both central battery
and self-contained systems. For the
3. ESCAP self-contained luminaires
central battery systems the options
using a maintenance-free
are WebACM, WebCM, ACM, BCM,
and environmentally friendly
Coba and BACnet, for self-contained
supercapacitor technology
luminaires the wireless Aalto Control
system. Further information about the
In central battery systems the batteries remote monitoring options can be found
and the most important actuators on the pages 41-45 of this catalogue.
are centrally located, which is a big
advantage concerning maintenance Teknoware TKT66 Central Battery Unit that
fullfils the requirements of the standard
and service. The larger the building, the EN 50171
bigger the advantage.
In self-contained luminaire systems each
luminaire has its own backup power
source, traditionally a battery. This kind of
a system is the most applicable in such
buildings, where the maintenance of the
batteries, located in each luminaire, can
be arranged with reasonable costs.
6
Teknoware Emergency Lighting Product Catalogue_T375
AN EMERGENCY LUMINAIRE IS A SAFETY
EQUIPMENT
The primary function of the main products are also 3rd party simulation with the Dialux software we
emergency lighting is to ensure a fast certified by SGS Fimko, as a sign of also offer the necessary Eulumdat files.
and safe evacuation of the building which they have a SGS-FI marking. The data of the luminaires is based on
in the case of emergency. This is real measurements and the simulations
valid both when the general lighting based on them. The luminous flux values
is working as well as when there is a are measured with the Ulbricht’s sphere
power outage. The escape route is in our own lighting laboratory.
marked with exit luminaires. The safe
moving there and in the open areas
is secured with emergency luminaires LEDS ARE TODAY´S TECHNOLOGY
giving general light. The observability The LEDs have been developing notably
of the exit luminaires becomes even fast regarding the light efficacy as well
more important when the general as the depandability. Nowadays the
THE PERFORMANCE
lighting is still functional, because the LEDs are a considerable option for very
pictograms in them must always clearly REQUIREMENTS FOR THE EXIT
many lighting applications. In emergency
stand out from the surroundings. LUMINAIRES lighting solutions, LEDs have been used
Also, the possible smoke poses a big for several years already. Teknoware has
The exit luminaires have to fulfill the
challenge to the observability of the been one of the pioneers in this field and
requirements of the European standard
exit lighting. continues to be it still today. Our first exit
EN 1838 regarding their performance.
The standard determines the luminaire with green LEDs, LEDMAN,
requirements both for the luminance and was introduced in the mid 90’s and more
In emergency lighting the performance
the contrasts. The minimum luminance of than 10 years ago we introduced our
of the luminaire is a crucial safety
the green area is 2 cd/m2, the contrast first exit luminaires with white LEDs. Even
factor, which means that it must always
between the white and the green area today, our luminaires are continuously
fulfill the requirements. This is ensured
must be between 1:5… 1:15 and within developed further by applying the most
by following the relevant standards.
the same colour the contrast must be advanced LED technology and optics.
The most important of them are the
European standards for emergency less than 1:10. These will guarantee the Today the LEDs play an important
lighting, EN 1838 and EN 60598-2-22 minimum observability for the pictogram. role also as the light source of the
for the luminaires and EN 50171 for This is the most important feature of an emergency luminaires giving overall
the central battery systems.In Europe exit luminaire and it cannot be neglected illumination. Compared to fluorescent
the responsibility for the conformity e.g. due to the quest for a lower energy tubes, they make it possible to design
of an electric device belongs to the consumption or the product costs. In a remarkably smaller luminaires with
manufacturer. As a sign of this the the end the owner of the building is also a considerable decrease in energy
manufacturer attaches a CE marking responsible that the emergency lighting consumption.
in the device. A common problem is, system is meeting the standards.
Compared to other light sources,
however, that the CE marking as such the LEDs mean, however, also new
alone does not guarantee the safety technical challenges for the design
of the device. The CE marking is only of the luminaires. The correct thermal
THE PHOTOMETRIC PROPERTIES
the manufacturer’s own promise, for design is crucial when it comes to the
which the arguments may be rather OF THE EMERGENCY LUMINAIRES
lifetime of the LED and the photometric
inadequate. A conscious manufacturer, The purpose of the emergency benefits can only be utilized with efficient
such as Teknoware, takes care of the luminaires is to give a minimum optics. At Teknoware we combine our
fulfilling the requirements already illuminance level of 1,0 lux for escape long-time experience with the utilization
in the design phase of the products. routes and 0,5 lux for open areas. In of the latest design tools and measuring
The only reliable way to do this is the order for this to be achieved, the devices in our design process.
measurements and tests according photometric data of each luminaire is
to the standards with appropriate needed in the system planning stage.
and calibrated measuring devices. The emergency luminaire standard
This goes for electromagnetic EN 60598-2-22 requires that the
compatibility, electric safety and also manufacturer of an emergency luminaire
for the performance of the product. must give the verified data for each
We can present these documents if luminaire. We have the luminous flux First LED exit luminaire, LEDMAN, made
requested. values and light distribution tables for in Teknoware, was launched already in the
mid-90s. Next to LEDMAN is Esc 90, which
In addition to the CE marking, our all our emergency luminaires. For the represents the latest LED technology.
7
Teknoware Emergency Lighting Product Catalogue_T375
REFERENCES
8
Teknoware Emergency Lighting Product Catalogue_T375
CENTRAL BATTERY UNITS
SWITCHED-MAINTAINED PACKAGE 40
CENTRAL MONITORING OPTIONS | WEBCM & WEBACM, ACM, BACNET, LON, BCM UNIT 41
9
Teknoware Emergency Lighting Product Catalogue_T375
FEATURES OF CENTRAL BATTERY UNIT FAMILIES
Basic information
Nominal Supply voltage 1~ 230 VAC 1~ 230 VAC 1~ 230 VAC 1~ 230 VAC
Output voltage, mains supply 24 VAC 24 VAC 230 VAC 230 VAC
Output voltage, battery supply 24 VDC 24 VDC 216 VDC 216 VDC
Battery voltage 24 VDC 24 VDC 216 VDC 216 VDC
Max. battery capacity 24 Ah 100 Ah 65 Ah 65 Ah
Max. output power, maintained 250 VA 1050 VA 1500 VA-2580 VA 2000 VA-2580 VA
Max. output power, maintained + 290 W 1370 W 2000 W-6000 W 2000 W-6000 W
non-maintained
Local Controller — — x x
Switch Controller — — x x
Address module — — x x
Intelligent Controller Interface — — — TST6551,
TST6552,
TST6553
| *) One Extra Charger Module enables to add battery capacity with 180 Ah (adds power taken from mains 3000 VA) | **) TKx66xxCFx = three phase input
| ***) Circuits can be connected in parallel to increase the output power up to 1400 VA / W
10
Teknoware Emergency Lighting Product Catalogue_T375
NEW
230 VAC 230 VAC 230 VAC 230VAC 230VAC 230 VAC
216 VDC 216 VDC 216 VDC 216VDC 216VDC 216 VDC
65 Ah 540 Ah 65 Ah — 540 Ah 65 Ah
2800 W-6000 W 5600 W-19600 W 2800 W-6000 W 2800 W-11200 W 5600 W-19600 W 2800 W-6000 W
x x x x x x
x x x x x x
x x x x x x
x x x x x x
— TST6741 — — TST6741 —
x x x x x x
x x x x x x
x x x x x x
11
Teknoware Emergency Lighting Product Catalogue_T375
ADDRESSABLE TAPSA CONTROL SYSTEMS
mains supply 1 2 3 4 32
Tapsa 1
Control
2
CBU
3 up to 32 luminaires
in the same circuit
free circuit
Battery arrangement
Cabinet
= non-maintained luminaire
12
Teknoware Emergency Lighting Product Catalogue_T375
MAIN/SUB CBU SYSTEM
Teknoware offers also an addressable the relative, calculatory reserve needs The Main / Sub Central Battery System
Tapsa Control Main / Sub Central to be taken into account only in one is mainly used in large buildings when
Battery System, where the batteries set of batteries. Within a fire zone it decentralized batteries are not preferred
are centralized in connection with is possible to make the cabling of the due to limitations of the available space.
the Main CBU and the DC power/ luminaires without using a fire-proof
voltage is distributed to the Sub units cabling. Centralized remote controlling,
via the battery cables. The Main / Sub testing and monitoring is done with the
Central Battery System makes it possible Teknoware’s ACM, the Advanced Central
to optimize the size of the batteries Monitoring software.
battery
cable
Modem
Geopolis University, Lausanne, Switzerland ANS-III Aerial Traffic Control Centre, Budapest Airport, Hungary
13
Teknoware Emergency Lighting Product Catalogue_T375
TAPSA CONTROL TKT67xxC *)
EN IP IP
50171 21 31
|* also available in IP31
)
ALWAYS NEEDS
230 V A MAXIMUM
18 BATTERIES,
ADDRESSABLE OF 32
A BATTERY
CENTRAL ADDRESSABLE
CABINET / RACK
BATTERY UNIT LUMINAIRES /
+
ONE CIRCUIT
BATTERY CABLES
Certified:
• TKT67XXCX
Central battery units in the TKT67 series luminaires connected to it. The testing non-maintained emergency luminaires.
offer effective solutions for supplying of luminaires is based on individual These central battery units have,
a large quantity of luminaires. They are addresses and the communication depending on the model, either 16, 24,
especially suited for large premises. is by means of the power supply 32, 40, 48 or 56 output circuits, which
The central unit input voltage is 230 cables. Thus there is no need for any can be set to function as maintained
VAC. The output voltage is 230 VAC separate data cabling between the or non-maintained. A maximum of
in normal mode and 216 VDC in luminaires. The luminaires must be of 32 addressable luminaires can be
battery mode. The battery voltage is the Teknoware model number ending in connected to one circuit. Circuits can
216 V, which is achieved by connecting the letter K or they must have a separate also be connected in parallel to increase
eighteen 12 volt batteries in series. address module. Utilisation of the se the output power with the following
luminaires also enables the connection changeover module outputs possible:
In addition to the normal emergency of maintained and non-maintained
lighting functions, central battery units 8 x 350 VA, 4 x 700 VA or 2 x 1400 VA.
luminaires to the same circuit and allows
in the Tapsa Control TKT67C series local supply monitoring using Teknoware
make it possible to test automatically the Local Controller, or Intelligent Controller,
condition of the central unit itself and the which can also be used to control the
DIMENSIONS
505 602
1950
1950
602
505
R597
14
Teknoware Emergency Lighting Product Catalogue_T375
TYPE OF THE CBU
Product code Max input Number of circuits / Max load, Max total load 1-3 h Weight
power (mains) Outputs maintained luminaires durations (kg)
OPTIONAL FEATURES
Product code Product description For
TST6731 Integrated Printer TKT67xxC
TST6732 LCD Display Module TKT67xxC
TST6741 Extra Charger Module (adds power taken from mains 3000 VA) 1-2 pcs each 3000 VA, Max each 180 Ah TKT67xxC
XWT6772 Switched-Maintained Package for 16 circuits each 350 W TKT6716C
XWT6773 Switched-Maintained Package for 24 circuits each 350 W TKT6724C
XWT6774 Switched-Maintained Package for 32 circuits each 350 W TKT6732C
XWT6775 Switched-Maintained Package for 40 circuits each 350 W TKT6740C
XWT6776 Switched-Maintained Package for 48 circuits each 350 W TKT6748C
XWT6777 Switched-Maintained Package for 56 circuits each 350 W TKT6756C
TST6751 IC Interface for 8 circuits each 350 W TKT6708C
TST6752 IC Interface for 16 circuits each 350 W TKT6716C
TST6753 IC Interface for 24 circuits each 350 W TKT6724C
TST6754 IC Interface for 32 circuits each 350 W TKT6732C
TST6755 IC Interface for 40 circuits each 350 W TKT6740C
TST6756 IC Interface for 48 circuits each 350 W TKT6748C
TST6757 IC Interface for 56 circuits each 350 W TKT6756C
Central monitoring options:
TST6722 LON Interface TKT67xxC
TST6701 BACnet Interface TKT67xxC
TST6721 ACM Interface TKT67xxC
TST6724 WebCM/ WebACM Interface TKT67xxC
TST1811E BCM Interface TKT67xxC
15
Teknoware Emergency Lighting Product Catalogue_T375
TAPSA CONTROL TKT68xxCx EN
50171
IP
20
A MAXIMUM
230 V NO SEPARATE
OF 32
ADDRESSABLE BATTERY
ADDRESSABLE
CENTRAL CABINET
LUMINAIRES /
BATTERY UNIT NEEDED
ONE CIRCUIT
Central battery units in the TKT68C Ah into its casing; therefore, it is well of maintained and non-maintained
series offer effective and space-saving suited for locations where only a limited luminaires to the same circuit and allows
solutions for supplying a moderate amount of space is available. local supply monitoring using Teknoware
quantity of luminaires. They are In addition to the normal emergency Local Controller, or Intelligent Controller,
especially suited for mid-sized and large lighting functions, central battery units which can also be used to control the
premises where it is desirable to divide in the Tapsa Control TKT68C series non-maintained emergency luminaires.
the central battery system into multiple make it possible to test automatically the These central batteryunits have,
independent regions. condition of the central unit itself and the depending on the model, either 8,
The central unit input voltage is 230 luminaires connected to it. The testing 16 or 24 output circuits, which can
VAC, except for the three phase input of luminaires is based on individual be set to function as maintained
models (that end in letter F), the input addresses and the communication of non-maintained. A maximum of
voltage, of which is 400 VAC between is by means of the power supply 32 addressable luminaires can be
the phases. The output voltage is 230 cables. Thus there is no need for any connected to one circuit. Circuits can
VAC in normal mode and 216 VDC in separate data cabling between the also be connected in parallel to increase
battery mode. The battery voltage is luminaires. The luminaires must be of the output power with the following
216 V, which is achieved by connecting the Teknoware model number ending in changeover module outputs possible:
eighteen 12 volt batteries in series. the letter K or they must have a separate 8 x 350 VA, 4 x 700 VA or 2 x 1400 VA.
TKT68C central battery unit can address module. Utilisation of these
accommodate batteries up to 18 x 65 luminaires also enables the connection
DIMENSIONS
512 800
1930 1930
800
512
R590
R188
R796
16
Teknoware Emergency Lighting Product Catalogue_T375
TYPE OF THE CBU
Product code Max input Number of circuits/ Max load, Max total load, Max total load, Weight
power (mains) Outputs maintained 1 h duration 3 h duration (kg)
luminaires
TKT6808C 3680 VA 8 circuits each 350 W 2580 VA 2800 W 2800 W 145,0
1 x (8x350 W / 4x700 W / 2x1400 W)
TKT6808CF 3900 VA 8 circuits each 350 W 2800 VA 2800 W 2800 W 145,0
1 x (8x350 W / 4x700 W / 2x1400 W)
TKT6816C 3680 VA 16 circuits each 350 W 2580 VA 5600 W 3340 W 147,0
2 x (8x350 W / 4x700 W / 2x1400 W)
TKT6816CF 6700 VA 16 circuits each 350 W 5600 VA 5600 W 3340 W 147,0
2 x (8x350 W / 4x700 W / 2x1400 W)
TKT6824C 3680 VA 24 circuits each 350 W 2580 VA 6000 W 3340 W 150,0
3 x (8x350 W / 4x700 W / 2x1400 W)
OPTIONAL FEATURES
Product code Product description For
TST6831 Integrated Printer TKT68xxC(F)
TST6832 LCD Display Module TKT68xxC(F)
XWT6871 Switched-Maintained Package for 8 circuits each 350 W TKT6808C(F)
XWT6872 Switched-Maintained Package for 16 circuits each 350 W TKT6816C(F)
XWT6873 Switched-Maintained Package for 24 circuits each 350 W TKT6824C(F)
TST6851 IC Interface for 8 circuits each 350 W TKT6808C(F)
TST6852 IC Interface for 16 circuits each 350 W TKT6816C(F)
TST6853 IC Interface for 24 circuits each 350 W TKT6824C(F)
Central monitoring options:
TST6822 LON Interface TKT68xxC(F)
TST6823 BACnet Interface TKT68xxC(F)
TST6821 ACM Interface TKT68xxC(F)
TST6824 WebCM/ WebACM Interface TKT68xxC(F)
TST1811F BCM Interface TKT68xxC(F)
17
Teknoware Emergency Lighting Product Catalogue_T375
TAPSA CONTROL TKT66xxCxx EN
50171
IP
20
IP
31
*)
Certified:
• TKT66XXCX
TKT66XXC(F) TKT6XXC(F)P
Central battery units in the TKT66C In addition to the normal emergency local supply monitoring using Teknoware
series offer effective and space-saving lighting functions, central battery units Local Controller, or Intelligent Controller,
solutions for supplying a moderate in the Tapsa Control TKT66C series which can also be used to control the
quantity of luminaires. They are make it possible to test automatically the non-maintained emergency luminaires.
especially suited for mid-sized and large condition of the central unit itself and the These central units have, depending
premises where it is desirable to divide luminaires connected to it. The testing on the model, either 8, 16 or 24 output
the central battery system into multiple of luminaires is based on individual circuits, which can be set to function
independent regions. addresses and the communication as maintained of non-maintained. A
The central unit input voltage is 230 is by means of the power supply maximum of 32 addressable luminaires
VAC, except for the three phase input cables. Thus there is no need for any can be connected to one circuit. Circuits
models (that end in letter F), the input separate data cabling between the can also be connected in parallel to
voltage, of which is 400 VAC between luminaires. The luminaires must be of increase the output power with the
the phases. The output voltage is 230 the Teknoware model number ending in following changeover module outputs
VAC in normal mode and 216 VDC in the letter K or they must have a separate possible: 8 x 350 VA, 4 x 700 VA or 2 x
battery mode. The battery voltage is address module. Utilisation of these 1400 VA.
216 V, which is achieved by connecting luminaires also enables the connection
eighteen 12 volt batteries in series. of maintained and non-maintained
luminaires to the same circuit and allows
DIMENSIONS
600 240
780 780
215 240
600
18
Teknoware Emergency Lighting Product Catalogue_T375
TYPE OF THE CBU
Product code Max input power Number of circuits / Max load, Max total Max total Weight
(mains) Outputs maintained load, 1 h load, 3 h (kg)
luminaires duration duration
TKT6608C(P) 3680 VA 8 circuits each 350 W 2580 VA 2800 W 2800 W 32,8
1 x (8x350 W / 4x700 W / 2 x1400 W)
TKT6608CF(P) 3900 VA 8 circuits each 350 W 2800 VA 2800 W 2800 W 32,8
1 x (8x350 W / 4x700 W / 2 x1400 W)
TKT6616C(P) 3680 VA 16 circuits each 350 W 2580 VA 5600 W 3340 W 33,8
2 x (8x350 W / 4x700 W / 2 x1400 W)
TKT6616CF(P) 6700 VA 16 circuits each 350 W 5600 VA 5600 W 3340 W 33,8
2 x (8x350 W / 4x700 W / 2 x1400 W)
TKT6624C(P) 3680 VA 24 circuits each 350 W 2580 VA 6000 W 3340 W 34,8
3 x (8x350 W / 4x700 W / 2 x1400 W)
OPTIONAL FEATURES
Product code Product description For
TST6631 Integrated Printer TKT66xxC(F)
TST6632 LCD Display Module TKT66xxC(F)
XWT6691 Charger Module TKT66xxC(F)
XWT6671 Switched-Maintained Package for 8 circuits each 350 W TKT6608C(F)
XWT6672 Switched-Maintained Package for 16 circuits each 350 W TKT6616C(F)
XWT6673 Switched-Maintained Package for 24 circuits each 350 W TKT6624C(F)
TST6651 IC Interface for 8 circuits each 350 W TKT6608C(F)
TST6652 IC Interface for 16 circuits each 350 W TKT6616C(F)
TST6653 IC Interface for 24 circuits each 350 W TKT6624C(F)
Central monitoring options:
TST6622 LON Interface TKT66xxC(F)
TST6601 BACnet Interface TKT66xxC(F)
TST6621 ACM Interface TKT66xxC(F)
TST6624 WebCM/ WebACM Interface TKT66xxC(F)
TST1811D BCM Interface TKT66xxC(F)
19
Teknoware Emergency Lighting Product Catalogue_T375
TAPSA CONTROL TKT65xxC EN
50171
IP
20
ALWAYS NEEDS
230 V A MAXIMUM
18 BATTERIES,
ADDRESSABLE OF 16
A BATTERY
CENTRAL ADDRESSABLE
CABINET / RACK
BATTERY UNIT LUMINAIRES /
+
ONE CIRCUIT
BATTERY CABLES
Certified:
• TKT65XXC
Central battery units in the TKT65C in the Tapsa Control TKT65C series luminaires to the same circuit and allows
series offer effective solutions for make it possible to test automatically the local supply monitoring using Teknoware
supplying a moderate number of condition of the central unit itself and the Local Controller, or Intelligent Controller,
luminaires. They are especially suited for luminaires connected to it. The testing which can also be used to control the
mid-sized and large premises where it of luminaires is based on individual non-maintained emergency luminaires.
is desirable to divide the central system addresses and the communication These central units have, depending
into multiple independent regions. is by means of the power supply on the model, either 8, 16 or 24 output
The central unit input voltage is 230 cables. Thus there is no need for any circuits, which can be set to function
VAC. The output voltage is 230 VAC separate data cabling between the as maintained or non-maintained. A
in normal mode and 216 VDC in luminaires. The luminaires must be of maximum of 16 addressable luminaires
battery mode. The battery voltage is the Teknoware model number ending in can be connected to one circuit.
216 V, which is achieved by connecting the letter K or they must have a separate
eighteen 12 volt batteries in series. address module. Utilisation of these
luminaires also enables the connection
In addition to the normal emergency of maintained and non-maintained
lighting functions, central battery units
DIMENSIONS
518 239
765
765
211
518
239 211
20
Teknoware Emergency Lighting Product Catalogue_T375
TYPE OF THE CBU
Product code Max input power Number of circuits/ Outputs Max load, maintained Max total load, Weight (kg)
(mains) luminaires 1 h duration
21
Teknoware Emergency Lighting Product Catalogue_T375
TKT65xxB EN
50171
IP
20
ALWAYS NEEDS
230 V 18 BATTERIES,
CENTRAL A BATTERY
BATTERY UNIT CABINET / RACK
+
BATTERY CABLES
Central battery units in the TKT65B series The central unit input voltage is 230 216 V, which is achieved by connecting
offer simple solutions for supplying a VAC, except for the three phase input eighteen 12 volt batteries in series.
moderate number of luminaires. They are models (that end in letter F), the input These central battery units have,
especially suited for mid-sized and large voltage, of which is 400 VAC between depending on the model, either 6, 12,
premises where it is desirable to divide the phases. The output voltage is 230 18 or 24 output circuits, which can be
the central battery system into multiple VAC in normal mode and 216 VDC in set to function as maintained or non-
independent regions. battery mode. The battery voltage is maintained in groups of two.
DIMENSIONS
518 239
765
765
518 211
239 211
22
Teknoware Emergency Lighting Product Catalogue_T375
TYPE OF THE CBU
Product code Max input power Number of circuits/ Max load, maintained Max total load, Weight
(mains) Outputs luminaires 1 h duration (kg)
TKT6506B 2600 VA 6 circuits each 250 W 1500 VA 2000 W 27,8
TKT6506BF 2600 VA 6 circuits each 250 W 1500 VA 2000 W 27,8
TKT6512B 3680 VA 12 circuits each 250 W 2580 VA 3000 W 30,0
TKT6512BF 4100 VA 12 circuits each 250 W 3000 VA 3000 W 30,0
TKT6518B 3680 VA 18 circuits each 250 W 2580 VA 4500 W 31,0
TKT6518BF 5600 VA 18 circuits each 250 W 4500 VA 4500 W 31,0
TKT6524B 3680 VA 24 circuits each 250 W 2580 VA 6000 W 31,6
TKT6524BF 7100 VA 24 circuits each 250 W 6000 VA 6000 W 31,6
OPTIONAL FEATURES
Product code Product description For
23
Teknoware Emergency Lighting Product Catalogue_T375
TKT31/41xx EN
50171
IP
20
Central battery units in the TKT3122 The central battery unit input voltage TKT3122 central battery unit has 4 output
and TKT41 series offer simple solutions is 230 VAC. The output voltage is 24 circuits, which can be set to function as
for supplying a relatively small number VAC in normal mode and 24 VDC in maintained or non-maintained in groups
of luminaires in a limited area. They battery mode. The battery voltage is 24 of two.
are especially suited for small premises V, which is achieved by connecting two
and applications where it is desirable to 12 volt batteries in series. TKT41 central
divide the central system into multiple battery units have, depending on the
independent regions. model, either 8 or 16 output circuits and
DIMENSIONS
420 244
602 602
420
244
24
Teknoware Emergency Lighting Product Catalogue_T375
TYPE OF THE CBU
Product Max Outputs Output circuit Max load, Max Space for Max Weight
code input maintained total batteries battery (kg)
power luminaires load, 1 h inside the capacity
(mains) duration unit
TKT3122 300 VA 4x Can be set in steps of two circuits / total 4 250 VA 290 W 2 x 12 V / 24 Ah 12,5
120 W circuits: 24 Ah
• maintained circuits max 120 W / circuit
• non-maintained circuits max 190 W / circuit
TKT4144 1300 VA 8x Can be set in steps of two circuits / total 8 1050 VA 1370 W 2 x 12 V / 100 Ah 24,0
120 W circuits: 38 Ah
• maintained circuits max 120 W / circuit
• non-maintained circuits max 190 W / circuit
TKT4188 1300 VA 16 x Can be set in steps of two circuits / total 16 1050 VA 1370 W 2 x 12 V / 100 Ah 24,5
120 W circuits: 38 Ah
OPTIONAL FEATURES
Product code Product description For
25
Teknoware Emergency Lighting Product Catalogue_T375
TAPSA CONTROL MAIN CBU TKM68xxCx NEW
EN IP
50171 20
230 V
ADDRESSABLE
A MAXIMUM
MAIN CBU NO SEPARATE
OF 32
BATTERY
ADDRESSABLE
CABINET
LUMINAIRES /
NEEDED
ONE CIRCUIT
POSSIBILITY TO
CONNECT
1-9 SUB CBUS
TO THE MAIN
CBU
TKM68C Main CBU offers an effective In addition to the normal emergency luminaires to the same circuit and allows
solution for supplying a large number lighting functions, central battery units local supply monitoring using Teknoware
of luminaires. They fit especially well in the Tapsa Control TKM68C series Local Controller, or Intelligent Controller,
in large buildings and depending of make it possible to test automatically the which can also be used to control the
amount and power of the luminaires, 1-9 condition of the central unit itself and the non-maintained emergency luminaires.
Sub CBUs (as a standard 9 Sub CBUs) luminaires connected to it. The testing These central battery units have,
can be connected to the Main CBU. of luminaires is based on individual depending on the model, either 8,
Each Sub CBU can have 8-32 luminaire addresses and the communication is by 16 or 24,output circuits, which can
circuits. means of the power supply cables. Thus be set to function as maintained
The central unit input voltage is 230 there is no need for any separate data or non-maintained. A maximum of
VAC. The output voltage is 230 VAC cabling between the luminaires. 32 addressable luminaires can be
in normal mode and 216 VDC in The luminaires must be of the Teknoware connected to one circuit. Circuits can
battery mode. The battery voltage is model number ending in the letter also be connected in parallel to increase
216 V, which is achieved by connecting K or they must have a separate the output power with the following
eighteen 12 volt batteries in series. address module. Utilisation of these changeover module outputs possible: 8
luminaires also enables the connection x 350 VA, 4 x 700 VA or 2 x 1400 VA.
of maintained and non-maintained
DIMENSIONS
512 800
FZ= Fire Zone
FZ1
Sub CBU
FZ2
Sub CBU
1930 1930 Normal
installation
cable
CAT 5/6
Battery
cable
512
Modem Batteries
R590
R188
R796
26
Teknoware Emergency Lighting Product Catalogue_T375
TYPE OF THE CBU
Product code Max input Number of circuits/ Max load, maintained Max total Max total Weight
power Outputs luminaires load, 1 h load, 3 h (kg)
(mains) duration duration
OPTIONAL FEATURES
Product code Product description For
TST6831 Integrated Printer TKM68xxC
TST6832 LCD Display Module TKM68xxC
XWT6871 Switched-Maintained Package for 8 circuits each 350 W TKM6808C
XWT6872 Switched-Maintained Package for 16 circuits each 350 W TKM6816C
XWT6873 Switched-Maintained Package for 24 circuits each 350 W TKM6824C
TST6851 IC Interface for 8 circuits each 350 W TKM6808C
TST6852 IC Interface for 16 circuits each 350 W TKM6816C
TST6853 IC Interface for 24 circuits each 350 W TKM6824C
Central monitoring options:
TST6822 LON Interface TKM68xxC
TST6823 BACnet Interface TKM68xxC
TST6821 ACM Interface TKM68xxC
TST6824 WebCM/ WebACM Interface TKM68xxC
TST1811F BCM Interface TKM68xxC
27
Teknoware Emergency Lighting Product Catalogue_T375
TAPSA CONTROL MAIN CBU TKM67xxC
EN IP
50171 21
ALWAYS NEEDS
A MAXIMUM
230 V 18 BATTERIES,
OF 32
ADDRESSABLE A BATTERY
ADDRESSABLE
MAIN CBU CABINET /
LUMINAIRES /
RACK + BATTERY
ONE CIRCUIT
CABLES
POSSIBILITY TO
CONNECT
1-12 SUB CBUS
TO THE MAIN
CBU
TKM67 Main CBU offer an effective lighting functions, central battery units local supply monitoring using Teknoware
solution for supplying a large number in the Tapsa Control TKM67xxC series Local Controller, or Intelligent Controller,
of luminaires. They fit especially well make it possible to test automatically the which can also be used to control the
in large buildings and depending of condition of the central unit itself and the non-maintained emergency luminaires.
amount and power of the luminaires, 1-12 luminaires connected to it. The testing These central battery units have,
Sub CBUs (as a standard 4 Sub CBUs) of luminaires is based on individual depending on the model, either
can be connected to the Main CBU. addresses and the communication 8, 16, 24, 32, 40, 48 or 56 output
Each Sub CBU can have 8-32 luminaire is by means of the power supply circuits, which can be set to function
circuits. cables. Thus there is no need for any as maintained or non-maintained. A
The central unit input voltage is 230 separate data cabling between the maximum of 32 addressable luminaires
VAC. The output voltage is 230 VAC luminaires. The luminaires must be of can be connected to one circuit. Circuits
in normal mode and 216 VDC in the Teknoware model number ending in can also be connected in parallel to
battery mode. The battery voltage is the letter K or they must have a separate increase the output power with the
216 V, which is achieved by connecting address module. Utilisation of these following changeover module outputs
eighteen 12 volt batteries in series. luminaires also enables the connection possible: 8 x 350 VA, 4 x 700 VA or 2 x
of maintained and non-maintained 1400 VA.
In addition to the normal emergency luminaires to the same circuit and allows
DIMENSIONS
FZ2
Sub CBU
Normal
1950 installation
1950
cable
CAT 5/6
Battery
cable
R597
28
Teknoware Emergency Lighting Product Catalogue_T375
TYPE OF THE CBU
Product code Max input power Number of circuits / Max load, maintained Max total load 1-3 h durations Weight
(mains) Outputs luminaires (kg)
OPTIONAL FEATURES
Product code Product description For
TST6741 Extra Charger Module (adds power taken from mains 3000 VA) 1-2 pcs each 3000 VA, Max each 180 Ah TKM67xxC
29
Teknoware Emergency Lighting Product Catalogue_T375
TAPSA CONTROL SUB UNIT TKB66xxCFx
EN IP IP *)
50171 20 21
|*) Sub unit with hinged front door IP21
230 V
NO SEPARATE
ADDRESSABLE A MAXIMUM
BATTERIES
SUB UNIT OF 32
NEEDED. THE
WITH 8-32 ADDRESSABLE
BATTERIES ARE
OUTPUT LUMINAIRES /
CONNECTED TO
CIRCUITS ONE CIRCUIT
THE MAIN CBU
ALSO AVAILABLE
WITH A DOOR
TKB66XXCF TKB66XXCFP WITH HINGES
The TKB66 Sub Units are used as a In addition to the normal emergency Local Controller, or Intelligent Controller,
part of the Main / Sub Central Battery lighting functions, central battery units which can also be used to control the
System. The Sub Unit doesn’t have its in the Tapsa Control TKB66 series make non-maintained emergency luminaires.
own batteries or charging device. The it possible to test automatically the These central units have, depending
battery voltage for the Sub Units is condition of the central unit itself and the on the model, either 8, 16 or 24 output
supplied from the Main CBU. luminaires connected to it. The testing circuits, which can be set to function
The cabling of the luminaires can be of luminaires is based on individual as maintained of non-maintained. A
done without a fire-proof cable when the addresses and the communication maximum of 32 addressable luminaires
Sub Unit and its luminaires are located is by means of the power supply can be connected to one circuit. Circuits
in within the same fire-zone, according cables. Thus there is no need for any can also be connected in parallel to
to the standard HD 60364-5-56. This separate data cabling between the increase the output power with the
brings savings in cabling costs. luminaires. The luminaires must be of following changeover module outputs
the Teknoware model number ending in possible: 8 x 350 VA, 4 x 700 VA or 2 x
The central unit input voltage is 400 the letter K or they must have a separate
VAC. The output voltage is 230 VAC 1400 VA.
address module. Utilisation of these
in normal mode and 216 VDC in luminaires also enables the connection
battery mode. The battery voltage is of maintained and non-maintained
216 V, which is achieved by connecting luminaires to the same circuit and allows
eighteen 12 volt batteries in series. local supply monitoring using Teknoware
DIMENSIONS
TKB66XXCF TKB66XXCFP
606 276
240 600
781
781
780 780
606
215 240
276
600
30
Teknoware Emergency Lighting Product Catalogue_T375
TYPE OF THE CBU
Product code Max input power Number of circuits / Max load, maintained luminaires Weight
(mains) Outputs (kg)
OPTIONAL FEATURES
Product code Product description For
31
Teknoware Emergency Lighting Product Catalogue_T375
PLACEMENT OF BATTERIES IN BATTERY
CABINETS
32
Teknoware Emergency Lighting Product Catalogue_T375
REMOTE SWITCHES
TST9602 230 V AC/DC Maintained / non-maintained • 2 operation modes can be selected by a dip switch
• Phase monitoring and switch control,
• PF contact for the cutting of external (DALI, 0-10 V, alarm) control
TST9602B 230 V AC/DC Maintained / non-maintained • 2 operation modes can be selected by a dip switch
• Phase monitoring and switch control,
• Dual PF contact for the cutting of external (DALI, 0-10 V, alarm) control
NOTE! There are differences in DALI compatible ballasts, depending of both manufacturer and product, please check the compatibility.
33
Teknoware Emergency Lighting Product Catalogue_T375
SWITCH CONTROLLER IP
20
*)
POSSIBLE TO
COMPATIBLE
ACTIVATE THE
WITH ALL
LUMINAIRES
TEKNOWARE
CONNECTED TO
CENTRAL
THE CENTRAL
BATTERY UNITS
BATTERY UNITS
HAVING A
USING EITHER A
230 VAC/DC
LIGHT SWITCH OR
OUTPUT
A TIMER
Certified:
• TST2802
Utilising the Switch Controller TST28xx, this case, all the luminaires will be lit Switch Controller has also a dimming
it is possible under normal mode to automatically whether the light switch is control output, which can be used to
activate the luminaires connected to the on or off. dim the light during emergency mode.
central battery unit using either a light The Switch Controller TST28xxx is The control output is compatible with
switch or a timer. compatible with all Teknoware central electronic ballasts having a 1-10V
During an emergency mode, the Switch battery units having a 230 VAC/DC dimming control input according to IEC
Controller switches the supply to take output. It can also be used with the Local 60929.
place from the central battery unit. In Controller.
SWITCH CONTROLLER
TST2802 TST2801/ TST2803(B)
TST2800
5,5
5,5
60 123 123 3,5
107 5,5 213
213 20 160
5,5 20
86
86 127 82 127
117
107 107
117
107
127 213
60
123
86 75
117 75
60 117 65
43 43
38 38
TST8501
150 150
4 140 4 140
150
32
44 44
32
44
34
Teknoware Emergency Lighting Product Catalogue_T375
Switch Controller
mains supply
230 V
AC/DC
CBU
SV
Depending of the type, in normal mode the
= non-maintained luminaire power is taken either from the CBU or from
a switch input
maintained exit luminaire SV = Switch Controller
SWITCH CONTROLLER
Product code Input Power Installation Features
voltage
TST2800 230 V 250 VA Inside a distribution panel • controls emergency lights by normal light switch
AC/DC • a dimming control output 1-10 V
TST2801 230 V 250 VA With the junction box enclosure (IP20) for • controls emergency lights by normal light switch
AC/DC independent installation • a dimming control output 1-10 V
TST2802 230 V 1400 VA Inside a distribution panel • controls emergency lights from central battery unit
AC/DC • a dimming control output 1-10 V
TST2803 230 V 1400 VA With the junction box enclosure (IP20) for • controls emergency lights from central battery unit
AC/DC independent installation • a dimming control output 1-10 V
TST2803B 230 V 1400 VA With the junction box enclosure (IP20) for • controls emergency lights by normal light switch
AC/DC independent installation • a dimming control output 1-10 V
TST8501 230 V 1000 VA Inside a distribution panel • controls emergency lights from central battery unit
AC/DC • inverting function in AC
35
Teknoware Emergency Lighting Product Catalogue_T375
LOCAL CONTROLLER IP
20
*)
ENABLES LOCAL
CONTROL OF
EXTRA SAFETY
EMERGENCY
WITH LOWER
LIGHTING
INSTALLATION
Certified: LUMINAIRES IN
COSTS
• TST6801 CENTRAL BATTERY
• TST6803 SYSTEMS
The Local Controller enables local The Local Controller is connected to connected luminaires remain lit after the
control of emergency lighting luminaires the emergency supply cabling between normal power supply has been restored
in central battery systems. It monitors the the central battery unit and luminaires. Both maintained and non-maintained
local supply, and controls the emergency Its monitoring inputs are connected to emergency luminaires can be connected
luminaires connected to it. It provides the mains supply of the local general to the same circuit wiring.
two remarkable advantages: lighting, and it can monitor up to 3
phases independently. If any of the Teknoware luminaires (when the code
• Local voltage breakdown switches ends with a letter K) can be installed as
monitoring inputs detect supply failure,
on the non-maintained emergency non-maintained when used with the
the Local Controller sends a message
luminaires, even if the supply to the Local Controller.
via supply cable to the non-maintained
central battery unit remains.
luminaires and they switch themselves Models TS90695, TS90696, TST6803,
on. When the supply recovers, the TST6804 and TST6805 have a relay
• Both maintained and non-maintained
normal operation returns automatically. output for controlling other devices. The
emergency luminaires can be
connected to the same circuit. This Models TS90695, TS90696, TST6803, relay output changes status when the
eliminates separate cabling for TST6804 and TST6805 also have a Local Controller is activated.
maintained and non-maintained switch control input and a potentiometer
luminaires. for setting a time delay so that the
60 86
60 86
5,5
60 107
65
86
38
38
43
117 43
123
127 127
82 127 82 127
127
213 127 213
75
75 75 75
TST6805
111 111
111
89
45
89
45
89
36
Teknoware Emergency Lighting Product Catalogue_T375
1-3-phase monitoring
TV TV
mains supply
230 V
AC/DC
CBU
Batteries
TV
LOCAL CONTROLLER
Product code Input Power Installation Feature
voltage
TS90686 230 V 250 VA With the junction box enclosure • 1-3-phase monitoring,
(IP20) for independent installation • Controlling the non-maintained luminaires through the supply cabling
TS90695 230 V 250 VA Inside a distribution panel • 1-3-phase monitoring /230 V control input,
• Controlling the non-maintained luminaires through the supply cabling,
• Switch control input,
• Relay contact output from 1-3-phase monitoring (NC/NO),
• 0-15 min adjustable delay for return to mains operations
TS90696 230 V 250 VA With the junction box enclosure • 1-3-phase monitoring /230 V control input,,
(IP20) for independent installation • Controlling the non-maintained luminaires through the supply cabling,
• Switch control input,
• Relay contact output from 1-3-phase monitoring (NC/NO)
• 0-15 min adjustable delay for return to mains operations
TST6801 230 V 1400 VA Inside a distribution panel, • 1-3-phase monitoring /230 V control input,
DIN rail compatible • Controlling the non-maintained luminaires through the supply cabling
TST6802 230 V 1400 VA With the junction box enclosure • 1-3-phase monitoring /230 V control input,
(IP20) for independent installation • Controlling the non-maintained luminaires through the supply cabling
TST6803 230 V 1400 VA Inside a distribution panel • 1-3-phase monitoring /230 V control input,
• Controlling the non-maintained luminaires through the supply cabling,
• Switch control input,
• Relay contact output from 1-3-phase monitoring (NC/NO),
• 0-15 min adjustable delay for return to mains operations
TST6804 230 V 1400 VA With the junction box enclosure • 1-3-phase monitoring /230 V control input,
(IP20) for independent installation • Controlling the non-maintained luminaires through the supply cabling,
• Switch control input,
• Relay contact output from 1/3-phase monitoring (NC/NO)
• 0-15 min adjustable delay for return to mains operations
TST6805 230 V 1400 VA Inside a distribution panel • Intelligent Controller (IC) compatible,
• 1-3-phase monitoring /230 V control input,
• Controlling the non-maintained luminaires through the supply cabling,
• Switch control input,
• Relay contact output from 1-3-phase monitoring (NC/NO),
• 0-15 min adjustable delay for return to mains operations
with 1 minute spacing with DIP Switch
37
Teknoware Emergency Lighting Product Catalogue_T375
ADDRESS MODULES
| Input voltage: 230 V AC/DC | Addresses: Max 32 addresses | Temperature range: -25…+50°C
| C = Compatible with the Tapsa Control central battery units | IC= Compatible with the Intelligent Controller | Local Controller= Compatible with the Local Controller
| DALI = Compatible with DALI function NOTE! There are differences in DALI compatible ballasts, depending of both manufacturer and product,
please check the compatibility.
TS98253 100 VA 1 VA / 1 W 10±5 mA 230 V DC Maintained / • Operation can be selected by a dip switch, 98 x 42 x 21
non-maintained • IC, C, Local Controller
TS98253B 100 VA 1 VA / 1 W 10±5 mA 230 V DC Maintained / • Operation can be selected by a dip switch, 142 x 30
non-maintained • IC, C, Local Controller, SLIM-model x 25
TS98254 200 VA 1 VA / 1 W 10±5 mA 230 V DC Maintained / • Operation can be selected by a dip switch, 150 x 43 x 32
non-maintained • IC, C, Local Controller
TS98255 625 VA 2 VA / 2 W 400 mA 230 V DC Maintained / • Operation can be selected by a dip switch, 150 x 43 x 32
non-maintained • C, Local Controller
TS98281 200 VA 1,5 VA / 1,5 W 10±5 mA 230 V Maintained / • Operation can be selected by a dip switch 150 x 43 x 32
AC/DC non-maintained • Phase input
• Switch control output,
• IC, C, Local Controller
Certified:
• TS98253
• TS98254
• TS98261
• TS98263
phase input
phase output
TS98281 Electronic
DALI BALLAST
ballast
Local e.g.
distribution light switch
DALI BALLAST board
TS98271 is connected to a luminaire, DALI-compatible address module, TS98281 is an address module with switch and supply monitoring
which simulates function of DALI-master. Setting of luminous output 10- input. Function is similar to the Local Controller and Switch
100% manually. Saves and resets data of DALI address module in memory. Controller. Address module is used with one luminaire and with one
controlled phase.
38
Teknoware Emergency Lighting Product Catalogue_T375
INTELLIGENT CONTROLLER (IC)
Teknoware’s IC (Intelligent Controller) The IC system consists of the following implementation, via a USB port, into the
system enables a large amount of components: IC Interface. The programming is saved
different options to turn the non- in the memory of the Central Battery
maintained emergency luminaires on • TKT65C, TKT66C, TKT67C or TKT68C, Unit, thus there is no need for the PC
and off, by using voltage inputs which addressable Tapsa Control Central except during the programming.
can be freely chosen. At the same Battery Unit Any input of any of the IC Input Modules
time, the voltage of several fuse boxes can be set to control any luminaire or
or general lighting can be monitored. • addressable, K-type Emergency luminaires, in any circuit. Furthermore,
When the voltage in one or several Luminaires logical switches can be programmed in
mains supply
TST6753 Interface + IC TKM6724C,
Tapsa 1 PC Software TKT6724C
Control
2
CBU TST6754 Interface + IC TKM6732C,
3
PC Software TKT6732C
39
Teknoware Emergency Lighting Product Catalogue_T375
SWITCHED-MAINTAINED PACKAGE
Switched-Maintained enables the Product Product description For
switching on/off of the emergency code
lighting circuits as maintained or non- XWT6771 Switched-Maintained Package for 8 circuits each 350 W TKM67xxC
maintained using an external relay or
XWT6772 Switched-Maintained Package for 16 circuits each 350 W TKT6716C,
switch. TKM67xxC
In the addressable central battery units XWT6773 Switched-Maintained Package for 24 circuits each 350 W TKT6724C,
TKM6724C
(except TK23xxC) it is possible to switch
on/off all the circuits of one circuit board XWT6774 Switched-Maintained Package for 32 circuits e ach 350 W TKT6732C,
TKM6732C
and it is also possible to select the type
XWT6775 Switched-Maintained Package for 40 circuits each 350 W TKT6740C,
of control as NO or NC. TKM6740C
The mode loops on the circuit boards XWT6776 Switched-Maintained Package for 48 circuits each 350 W TKT6748C,
are replaced with the Switched- TKM6748C
Maintaned unit. XWT6777 Switched-Maintained Package for 56 circuits each 350 W TKT6756C,
TKM6756C
In non-addressable central battery
XWT6871 Switched-Maintained Package for 8 circuits each 350 W TKT6808C,
units and in TK23xxC one circuit and in TKM68xxC
TKT31/41 two circuits can be controlled XWT6872 Switched-Maintained Package for 16 circuits each 350 W TKT6816C,
at a time. TKM68xxC
Switched-Maintained is available as an XWT6873 Switched-Maintained Package for 24 circuits each 350 W TKT6824C ,
TKM68xxC
option for all Teknoware central battery
XWT6671 Switched-Maintained Package for 8 circuits each 350 W TKT6608C,
units. TKB66xxCFx
Teknoware
CBU
= non-maintained
emergency luminaire
40
Teknoware Emergency Lighting Product Catalogue_T375
WEBCM & WEBACM
WebCM enables central monitoring of
the central battery systems via Internet.
The system consists of a Web module
connected to a central battery unit. Each
central battery unit has an individual IP
address and an ordinary Internet browser
serves as a user interface.
The basic system indicates the state of
the central battery unit and the luminaires
mains supply
Tapsa
Control
PC IP CBU outputs
TCP/IP P/
C
T
Battery
Cabinet
INTERNET
PC IP
P/
TC
41
Teknoware Emergency Lighting Product Catalogue_T375
ACM
Teknoware’s Advanced Central
Monitoring (ACM) is a central
monitoring system utilising a separate
network for the Tapsa Control central
battery units. ACM utilises RS485
protocol, which makes communications
possible even if the distance between
the central battery unit and the computer
is up to 1 km.
ACM’s PC Software screen displays the
status of all the central battery units and
the luminaires connected to them. The
user may also run battery and luminaire
tests. ACM saves the test log book
information automatically as per the
requirements of fire safety authorities.
By using the computer equipped with
ACM, it is possible to connect, e.g., to a
BACnet building automation system
Battery
TST6521 ACM Interface TKT65xxC Unit
Central
Battery
CAT 5/6
Unit
Central
Battery
Unit
CAT 5/6
Central
Battery
PC
Unit
SB /6
T5
U
CA
Modem
= non-maintained emergency luminaire
42
Teknoware Emergency Lighting Product Catalogue_T375
BACNET
The BACnet module in the central
battery unit allows it to be connected
directly to a building automation system.
The BACnet application make it possible
to access all the information supplied by
the central battery unit. In the BACnet
interface, information is transferred
as BACnet objects. Teknoware uses
BACnet modules as an interface to
Ethernet switch
Central
TCP / IP NETWORK CAT 5/6 Battery
Unit
CAT 5/6
Central
Battery
Unit
43
Teknoware Emergency Lighting Product Catalogue_T375
LON
Product Product For
LON central monitoring solution is
code description based on the COBA Building Operating
TST6722 LON Interface TKT67xxC, System, which offers a standard open
TKM67xxC platform for building automation and
TST6822 LON Interface TKT68xxC, security systems. The LON interface
TKB68xxC
also makes it possible to access all
TST6622 LON Interface TKT66xxC, information from the field in a centralised
TKB66xxC
manner. The system consists of an open
TST6522 LON Interface TKT65xxC LON network and a server, which link
XKT2301 LON Interface TK23xxC the central battery units together.
| Also a separate COBA Software is needed for the PC.
Central
battery
2C LON
unit
Central
battery
2C LON
unit
Central
battery
unit
2C LON
Central
battery
PC
unit
N
SB LO
U
2C
TC
LNI
P
/
N
IP
44
Teknoware Emergency Lighting Product Catalogue_T375
BCM UNIT
Product code Product description Supply voltage Casing Temperature range Input fuse
TST1809 Basic Central Monitoring Unit 1 ~230 V AC 50 Hz IP20 +10... 30 °C Glass-tube fuse 1 AT 5 x 20mm
with Printer
TST1809B Basic Central Monitoring Unit 1 ~230 V AC 50 Hz IP20 +10... 30 °C Glass-tube fuse 1 AT 5 x 20mm
without Printer
Product code Product description For Basic Central Monitoring unit (BCM)
TST1811E BCM Interface TKT67xxC is possible to be connected in all
319
260
192
Certified:
• TST1809
68 69 • TST1809B
260 130 Central
Battery
Unit
Central
Battery
Unit
Central
Battery
BCM
Unit
3-c ta cable
o r e da
Central
Battery
Unit
45
Teknoware Emergency Lighting Product Catalogue_T375
REFERENCES
46
Teknoware Emergency Lighting Product Catalogue_T375
EXIT AND EMERGENCY LUMINAIRES
ESCAP SELF-CONTAINED LUMINAIRES 48
AALTO CONTROL 50
TEKNOWARE ESCAP / AALTO CONTROL EXIT AND EMERGENCY LUMINAIRE PRODUCT RANGE 52
TEKNOWARE BATTERY + AALTO CONTROL EXIT AND EMERGENCY LUMINAIRE PRODUCT RANGE 53
SELF-CONTAINED LUMINAIRES WITH BATTERY 54
CENTRALLY SUPPLIED LUMINAIRES 56
ESC 90 | TWT90 60 NEW
ESC 80 | TWT80 62 NEW
ESC 81 | TWT81 64 NEW
ESC 10 | TW850, TWS85, TW802, TW844, TW868, TWS86 66-72
ESC 20 | TWT46, TWT47, TWT48 74-78
SILVER | TWT65, TWT66, TWT67, TWT68 80 NEW
ESC 6L | TWT62, TWS62 82
EXIT LUMINAIRES
ESC 6 | TWT60, TWS60 84
ESC 0,5 | TW416 86
ESC 1,5 | TW417 88
ESC 3 | TW397, TW494 90
ESC CUBE | TWK63 92
ESC 29 | TWT29, TWS29 94
ESC 82 | TWT82 96
SAFE 29 | TWT29, TWS29 98
SAFE 82 | TWT82 102
SAFE 6 | TWT82 106
TRISPOT | TWT75, TWT76 110
LINESPOT | TWT50, TWS50, TWT78, TWS78 112, 122
ZONESPOT | TWT64, TWS64, TWT94, TWS94 114, 124
ZONESPOT II | TWT04 116
NEW
EMERGENCY LUMINAIRES
47
Teknoware Emergency Lighting Product Catalogue_T375
ESCAP SELF-CONTAINED LUMINAIRES
Cutting-edge technology for Teknoware solves the battery problem of controlled accurately and as wide
emergency lighting self-contained luminaires by replacing a relative voltage range as possible
For emergency lighting there have been the batteries with Escap technology. must be utilised when the capacitor is
and still are only two basic solutions, Using LED luminaires and the wireless discharged. Teknoware has developed
both of which are determined by the Aalto Control remote management special power converter technology
location of the battery: system together, it is possible to create to overcome these challenges and as
a solution where the advantages of a result, it has been possible to utilise
• Central battery systems, where a both central battery and self-contained this quickly advancing technology in
central battery bank powers several systems can be combined and the practical applications.
luminaires disadvantages eliminated.
Es
ca
p
Charge level
Escap recharge time
Discharge time from 2 h
approx. 1.5 h
Mains supply 0 2 4 6 8 10 12 14 16 18 20 22 24
failure Charge time (h)
48
Teknoware Emergency Lighting Product Catalogue_T375
Maintenance-free service for more
than ten years
Escap technology makes it possible to
manufacture self-contained luminaires
which contain no harmful substances
and which require no regular battery
replacements. Capacitors have a lifespan
of over ten years, which matches the life
expectancy of modern surface mount
LEDs. As a result, the luminaire does not
require maintenance during its lifespan.
In addition, it does not contain any
hazardous waste, so it can be recycled
at the time of disposal like any ordinary
electronic waste.
As an energy source, the capacitor
offers the added advantage of having
much shorter charge time in comparison Environmental protection forms a part of our shared social responsibility. Here at Teknoware, we do our
to traditional battery technology. As a part by lowering emissions. The best way to do this is with our own award-winning, innovative know-how.
MAINTENANCE FREE
Performance
p
ca
Es
E
IC
V
SER Hospital of Vestfold, Tønsberg, Norway
2 4 6 8 10 Age (years)
49
Teknoware Emergency Lighting Product Catalogue_T375
AALTO CONTROL
WIRELESS
TECHNOLOGY
EXPANSION OF
THE SYSTEM
Several Zigbee
ZIGBEE ETHERNET EVERYTHING AT A GLANCE Ethernet Coordinators
COORDINATOR can be included in one
Aalto Control system
In the new Aalto Control 4.0 Aalto Control software collects data
(Max 30 pieces).
system, the PC and Zigbee from all luminaires. Software has one
logbook which saves all test data from This is useful when e.g.
Ethernet Coordinator can
every luminaire. Software has a very user- the system is desired
be positioned freely, e.g. in
friendly map which clearly shows what is to be divided in
separate rooms or buildings.
the status of luminaires at the moment. different sections, e.g.
The communication is done via by separate buildings.
Adding or moving luminaires is very
Ethernet connection.
simple and easy.
50
Teknoware Emergency Lighting Product Catalogue_T375
NEW AALTO CONTROL 4.0
Exit and Emergency Exit Luminaires New features in Aalto Control 4.0
System features (Max 800 Luminaires / Coordinator)
• Up to 5 000 luminaires in one Aalto Control system
• Central remote monitoring through several Aalto Zigbee
Ethernet Coordinators, from one location
• Distribution of the system into different sections, e.g.
buildings
• Free positioning of the system components in Ethernet
network
• An expanded operation area by using Zigbee Wall Routers
in challenging locations
• Renewed graphic look
Zigbee Coordinator • Renewed user interface
(Max 30 pcs)
• Luminaire information is shown with an RF-ID code, the
Ethernet
type of the luminaire, the location of the luminaire or
PC optional text fields
• Details of luminaire are shown with a mouse-over function
in the floor plan
• During commissioning the luminaire data can be fed with
As a minimum, a complete system requires a CSV file, manually, with a bar code reader or with the
the following equipment: automatic search function
• PC with Aalto Control Software (TST5104x)
• Ethernet Coordinator (TST5103)
• Aalto Control compatible luminaires
TECHNICAL DATA
Indoor range up to 40 m
RoHS Compatible
TST5102 Aalto Monitoring Device (wall mounted) Aalto Control always includes Lumi Test
With the Aalto Monitoring Device, Aalto Control Exit and Emergency Lumi Test self-diagnosis, which is available for
Luminaires in can be wirelessly monitored in Aalto Control Network. The self-contained luminaires, automatically tracks
wall-mounted Aalto Monitoring Device is meant for small Aalto networks, and tests the reliable operation of the luminaires.
of up to 100 luminaires. LED indicators (one green and one red) display
Aalto Monitoring Device enables the monitoring of luminaires, and the status of the luminaires. Red LED indicates
setting them into blink mode, as well as printing of a status report with the fault. The luminaire´s functionality and light source
integrated printer. are tested daily. Full emergency mode duration is
tested every 6 months. Product codes of the self-
Product code Product description contained luminaires with self-testing
TST5102 Wall mounted device for Aalto Control network monitoring end in letter M or A.
51
Teknoware Emergency Lighting Product Catalogue_T375
TEKNOWARE ESCAP / AALTO CONTROL
EMERGENCY AND EXIT LUMINAIRE PRODUCT RANGE
| Supply voltage: 230 V AC | Light source: LED | Escap = Self-contained luminaire with 1 h capacitor backup
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing
52
Teknoware Emergency Lighting Product Catalogue_T375
TEKNOWARE BATTERY + AALTO CONTROL
EMERGENCY AND EXIT LUMINAIRE PRODUCT RANGE
| Supply voltage: 230 V AC | Light source: LED | Aalto = Aalto Control compatible (incl. Lumi Test)
53
Teknoware Emergency Lighting Product Catalogue_T375
SELF-CONTAINED LUMINAIRES WITH BATTERY
| Supply voltage 230 V AC
| M = Self-contained luminaire with Lumi Test self-testing
TWT8283 8W G5 3 h battery 96
54
Teknoware Emergency Lighting Product Catalogue_T375
SELF-CONTAINED LUMINAIRES WITH BATTERY
| Supply voltage 230 V AC
| M = Self-contained luminaire with Lumi Test self-testing
55
Teknoware Emergency Lighting Product Catalogue_T375
CENTRALLY SUPPLIED LUMINAIRES
| Supply voltage: 24-230 V AC/DC
| CBU = Centrally supplied
56
Teknoware Emergency Lighting Product Catalogue_T375
CENTRALLY SUPPLIED LUMINAIRES
| Supply voltage: 24 V AC/DC
| CBU = Centrally supplied
57
Teknoware Emergency Lighting Product Catalogue_T375
CENTRALLY SUPPLIED LUMINAIRES
| Supply voltage: 230 V AC/DC
| CBU = Centrally supplied
| C = Compatible with Teknoware Tapsa Control central battery units
TWT6281K 8W G5 CBU / C 82
58
Teknoware Emergency Lighting Product Catalogue_T375
CENTRALLY SUPPLIED LUMINAIRES
| Supply voltage: 230 V AC/DC
| CBU = Centrally supplied
| C = Compatible with Teknoware Tapsa Control central battery units
59
Teknoware Emergency Lighting Product Catalogue_T375
ESC 90
Protection
EN EN -o- LED
Class II IP RAL
60598-2-22 1838 44 9003
CEILING
AND WALL
25 M MOUNTING
VIEWING AS STANDARD
DISTANCE
Certified:
• TWT9051WK
283
120 37
268 40 13 18 15
5 64 21 40
187
125
21 102
94
7
297
(dims: X=320, Y=165, Z=305, A=340)
| Aperture for recess mounting 45 x 275 mm
60
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
The corresponding luminaires ending in letter Q are always individually packed and include set of pictograms (see the pictogram table).
EXIT LUMINAIRES
TWT9051WKQ 230 V 6,6 VA / CBU / C -30…+50°C 2/3 x 2,5 mm2 0,44
AC/DC 4,2 W -o-
| Viewing distance: 25 m | Light source: LED | Protection rating: IP44
The corresponding luminaires ending in letter Q are always individually packed and include set of pictograms (see the pictogram table).
PICTOGRAMS ACCESSORIES
Product code Pictogram Product description Product code Product
PB9007 White label (1 pc supplied with the luminaire) TW77508B Shock protecting covers
(dims: X=320, Y=165, Z=305, A=340)
PB9006 Down arrow
61
Teknoware Emergency Lighting Product Catalogue_T375
ESC 80
Protection
EN EN -o- LED
Class II IP RAL
60598-2-22 1838 44 9003
CEILING
AND WALL
20 M LUMINAIRES 20-26 M
MOUNTING
VIEWING
AS STANDARD
DISTANCE
26 M LUMINAIRES
20 M
120
268 40 13 18
5 64 21 21 102
187
125
DIMENSIONS
26 M
268 120
40 13 64 18
5 21 102
21
64 5
202 120
130
62
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
Product code Supply voltage Max input power Operation Temperature Electrical installation Weight
EXIT LUMINAIRES
mode range (kg)
94
7
297
63
Teknoware Emergency Lighting Product Catalogue_T375
ESC 81
Protection
EN EN -o- LED
Class II IP RAL
60598-2-22 1838 44 9003
CEILING
AND WALL
40 M
MOUNTING
VIEWING
AS STANDARD
DISTANCE
DIMENSIONS
120
405 13 18
40 5 64 21
268
270
200
21 102
64 5
120
64
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
EXIT LUMINAIRES
SELF-CONTAINED LUMINAIRES 850 °C
Product code Supply voltage Max input Operation mode Temperature Electrical installation Weight
power range (kg)
TWT8153WA 230 V N/A 3 h battery + Aalto -5…+30°C 2/3 x 2,5 mm2 2,1
AC -o-
ACCESSORIES
Product code Product
SHOCK PROTECTING COVER SUSPENSION BRACKET
TWT8101 Recess mounting frame
TW77510B TWT9000
TWT8102 Flag bracket
85
TWT9000 Suspension bracket
65
Teknoware Emergency Lighting Product Catalogue_T375
ESC 10 EN
60598-2-22
EN
1838
-o- LED IP
20
A BRACKET
30 M IS ALWAYS
VIEWING NEEDED
DISTANCE
Certified:
• TW85081K
45
70
122
287
287 272 272
251
215 30 51
167 21
21
68
33
30 51
33
324 76 369
8 324
94
66
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
| Viewing distance: 30 m | Light source: 6W G5 fluorescent tube or LED | Protection rating: IP20
EXIT LUMINAIRES
SELF-CONTAINED LUMINAIRES 850 °C
Product code Supply Max input power Operation Temperature Electrical installation Weight
voltage mode range (kg)
ACCESSORIES
Product code Product
67
Teknoware Emergency Lighting Product Catalogue_T375
ESC 10 EN
60598-2-22
EN
1838
-o- LED IP
20
A BRACKET
40 M IS ALWAYS
VIEWING NEEDED
DISTANCE
Certified:
• TW80281K
28 239 68 76
27 8
70
122 45
311
326 311
326
324
21 215
167 51 30
68
51 30 21
33
33
68
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
| Viewing distance: 40 m | Light source: LED or 8W G5 fluorescent tube | Protection rating: IP20
EXIT LUMINAIRES
SELF-CONTAINED LUMINAIRES 850 °C
Product code Supply voltage Max input power Operation mode Temperature range Electrical installation Weight
(kg)
69
Teknoware Emergency Lighting Product Catalogue_T375
ESC 10 EN
60598-2-22
EN
1838
-o- LED IP
20
FOR
30 M WALL
VIEWING MOUNTING
DISTANCE
Certified:
• TW84481K
DIMENSIONS
277
6 265
277 95
21 30
52 52 41
71
219 219
219
70
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
| Viewing distance: 30 m | Light source: LED or 6 W G5 fluorescent tube | Protection rating: IP20
EXIT LUMINAIRES
SEPARATELY ORDERED PICTOGRAMS
Product code Pictogram Product description
ACCESSORIES
Product code Product
71
Teknoware Emergency Lighting Product Catalogue_T375
ESC 10 EN
60598-2-22
EN
1838
-o- LED IP
20
RAL
9003
Certified:
• TW86881K
SELF-CONTAINED LUMINAIRES
DIMENSIONS DIMENSIONS
268 113
295 242
72 75
265
62
74 74
83
83 6
6
254 6 246 246
268
295 200
6
279
72 38
169
136
72
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
| Viewing distance: 30 m | Light source: LED or 6W G5 fluorescent tube | Protection rating: IP20
| Luminaires in the table are SLIM models
EXIT LUMINAIRES
SELF-CONTAINED LUMINAIRES 850 °C
Product code Supply voltage Max input power Operation Temperature Electrical installation Weight
mode range (kg)
73
Teknoware Emergency Lighting Product Catalogue_T375
ESC 20 EN
60598-2-22
EN
1838
-o- LED IP
20
RAL
9006
CEILING
AND
20 M WALL
VIEWING MOUNTING
DISTANCE AS STANDARD
DIMENSIONS
164 73 164
21
145
6
58
29
158 158 158
15 29 21
34 52
27
74
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
EXIT LUMINAIRES
SEPARATELY ORDERED PICTOGRAMS
Product code Pictogram Product description
ACCESSORIES
Product code Product
Max.
1000mm
43
57
179
75
Teknoware Emergency Lighting Product Catalogue_T375
ESC 20 EN
60598-2-22
EN
1838
-o- LED IP
20
RAL
9006
CEILING
AND
26 M WALL
VIEWING MOUNTING
DISTANCE AS STANDARD
DIMENSIONS
TWT47XX TW89053W
6
187 187 29
246
190 246 187
29 21
15 43 42 43
158 22
28
3,5
64 85
35 21 21
5,5
76
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
Product code Supply voltage Max input power Operation Temperature Electrical installation Weight
mode range (kg)
SELF-CONTAINED LUMINAIRES
EXIT LUMINAIRES
Product code Supply voltage Max input power Operation Temperature Electrical installation Weight
mode range (kg)
ACCESSORIES
Product code Product
220 85
5 190 5,5
115
43
145
120
Max.
1000mm
43
57
179
77
Teknoware Emergency Lighting Product Catalogue_T375
ESC 20 EN
60598-2-22
EN
1838
-o- LED IP
20
RAL
9006
CEILING
AND
40 M WALL
VIEWING MOUNTING
DISTANCE AS STANDARD
DIMENSIONS
TWT48XX TW89153W
21 318
16 29
43 42 44 66 180
3,5 22
28
35
12
65 21 85 5,5
21
78
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
EXIT LUMINAIRES
SELF-CONTAINED LUMINAIRES
Product code Supply Max input power Operation Temperature Electrical Weight
voltage mode range installation (kg)
ACCESSORIES
Product code Product
Max.
1000mm
43
57
179
79
Teknoware Emergency Lighting Product Catalogue_T375
SILVER EN
60598-2-22
EN
1838
-o- LED IP
20
N
OMING SOO
SUSPENSION MOUNTING
C 30 M
VIEWING
TWT6551WK DISTANCE
FLAG MOUNTING
TWT6651WK
MODELS FOR
SUSPENSION,
FLAG,
WALL
AND
RECESS
MOUNTING
DIMENSIONS
TWT6551WK TWT6651WK
280
60
203
15
15
51
203
200
30
60
19,5 42 42 19,5
200
51 348
51
14
350 14
65 65
TWT6851WK
410 74
74
30
30
363 52
355 26
20
16
20 35 20
21
31
11
80
35
TWT6751WK
21
350 217
198
16 86 16
49
16
200
102
21 350 14
117
40
36
16
25
56 30 56
5,4
4
72,5 210
21
80
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
TWT6751WK 230 V 10,4 VA / CBU / C 3 x 2,5 mm2 1,8 Wall mounting, either
AC/DC 6,5 W -o- surface or semi-
recessed mounting
EXIT LUMINAIRES
SEPARATELY ORDERED PICTOGRAMS
Pictogram Product description
Down arrow
Right arrow
Left arrow
Down arrow
Right arrow
Left arrow
| 1-sided= TWT6751WK
| 2-sided= all other models
81
Teknoware Emergency Lighting Product Catalogue_T375
ESC 6L EN
60598-2-22
EN
1838
-o- LED IP
44
RAL
9003
WALL AND
CEILING
40 M MOUNTING
VIEWING AS
DISTANCE STANDARD
Certi fied:
• TWT6251WK
• TWT6281K
CEILING MOUNTING
455
75 455
21 30
295 295
295
455
404 4,5
21 30
FLAG MOUNTING
37 XWT6213
75 40
462
7
82
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
TWT6271W 230 V 24 V= 7,3 VA / 4,6 W LED CBU -30…+50°C 24 V= 2 x 2,5 mm2 1,6
AC/DC 230 V= 14,6 VA / 5 W 230 V=3 x 2,5 mm2
-o-
TWT6251WK 230 V 8,3 VA / 4,6 W LED CBU / C -30…+50°C 3 x 2,5 mm2 1,6
AC/DC + IC -o-
| Viewing distance: 40 m | Light source: LED or 8W G5 fluorescent tube | Protection rating: IP44
EXIT LUMINAIRES
Product code Supply Max input power Operation Temperature Electrical installation Weight
voltage mode range (kg)
PB103 Multifunction
ACCESSORIES
Product code Product
420
341
57
83
Teknoware Emergency Lighting Product Catalogue_T375
ESC 6 EN
60598-2-22
EN
1838
-o- LED IP
44
RAL
9003
CEILING,
WALL
AND FLAG
22 M
MOUNTING
VIEWING
AS
DISTANCE
STANDARD
Certified
• TWS6092W
267 63
20 79 281
121 24 20 21 17 14
31
65
21
18 21 23 63
18
124
84
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
=Colour of the body
9003
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
TWT6071WS 24-230 V 24 V= 7,5 VA / 4 W LED CBU -30…+50°C 24 V= 2/3 x 2,5 mm2 0,8
AC/DC 230 V= 11 VA / 4 W 230 V= 2/3 x 2,5 mm2
-o-
EXIT LUMINAIRES
TWT6051WK 230 V 8,3 VA / 4,6 W LED CBU / C + IC -30…+50°C 3 x 2,5 mm2 0,8
AC/DC -o-
TWT6051WKS 230 V 8,3 VA / 4,6 W LED CBU / C + IC -30…+50°C 2/3 x 2,5 mm2 0,8
AC/DC -o-
| Viewing distance: 22 m | Light source: LED or 6W G5 fluorescent tube | Protection rating: IP44
SELF-CONTAINED LUMINAIRES
Product code Supply Input power Light Operation Temperature Electrical installation Weight
voltage source mode range (kg)
PB047 Multifunction
85
Teknoware Emergency Lighting Product Catalogue_T375
ESC 0,5 EN
60598-2-22
EN
1838
-o- LED IP
20
RAL
9003
WALL
MOUNTING
20 M
AS
VIEWING
STANDARD
DISTANCE
DIMENSIONS
204 67 150
5
123 75
86
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
TW41671W 24-230 V 24 V= 7,5 VA / 4 W LED CBU -30…+50°C 24 V=2 x 2,5 mm2 0,8
AC/DC 230 V= 11 VA / 4 W 230 V=3 x 2,5 mm2
-o-
EXIT LUMINAIRES
SEPARATELY ORDERED PICTOGRAMS
Product code Pictogram Product description
PB101 Multifunction
ACCESSORIES
Product code Product
100
200 200
50
50 50
190
122 122
87
Teknoware Emergency Lighting Product Catalogue_T375
ESC 1,5 EN
60598-2-22
EN
1838
-o- LED IP
20
RAL
9003
WALL
MOUNTING
40 M AS
VIEWING STANDARD
DISTANCE
CAN BE
USED AS AN
EXIT OR AN
EMERGENCY
LUMINAIRE
DIMENSIONS
423 5 316
204 162
67
204
88
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | =Colour of the body
RAL
9003
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
EXIT LUMINAIRES
PB171B Down arrow
PB103 Multifunction
190
240
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
4 4,3 4 10 4 4 4,3 4 7 7 4
89
Teknoware Emergency Lighting Product Catalogue_T375
ESC 3 EN
60598-2-22
EN
1838
-o- IP
20
IP
44
WALL AND
SUSPENSION
70 - 120 M MOUNTING
VIEWING AS STANDARD
DISTANCE
HOOKS
INCLUDED
IN THE
PACKAGE
TWT397XX
29 647
647 121
30
21
194
5
391 391 391
72 500
21 1117
39 1025
121
6
TWT494XX
1259
1259 121 96 29 30
5 21
128 1000
634 634
634
39 21 509
413
121
6
90
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
| Viewing distance: 70 m | Light source: 18 W 13G fluorescent tube | Protection rating: IP44
| Luminaire can be used only as single sided.
EXIT LUMINAIRES
TW49481K < 120 m 230 V 38 VA / 36 W G13 CBU / C -10…+50°C 3 x 2,5 mm2 9,8
AC/DC 32 W -o-
| Viewing distance: 120 m | Light source: 36 W 13G fluorescent tube | Protection rating: IP20
| Luminaire can be used only as single sided.
91
Teknoware Emergency Lighting Product Catalogue_T375
ESC CUBE EN
60598-2-22
EN
1838
-o- IP
20
RAL
9003
CEILING
MOUNTING
65 M AS
VIEWING STANDARD
DISTANCE
DIMENSIONS
362
371
5 362
260
21 26
371 270
26
92
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
| Viewing distance: 65 m | Light source: 18 W 2G11 fluorescent tube | Protection rating: IP20
EXIT LUMINAIRES
SEPARATELY ORDERED PICTOGRAMS
Product code Pictogram Product description
ACCESSORIES
Product code Product
85 43
115
5,5
Max.
1000mm
43
57
417
93
Teknoware Emergency Lighting Product Catalogue_T375
ESC 29 EN
60598-2-22
EN
1838
-o- IP
65
RAL
9003
WALL AND
SURFACE
30 M MOUNTING
VIEWING AS STANDARD
DISTANCE
DIMENSIONS
341
341 270
21
32
53
189 94 189
80
94
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
TWT2951WK 230 V 8,3 VA / 4,6 W LED CBU / C -30…+50°C 3 x 2,5 mm2 1,2
AC/DC + IC -o-
TWT2971W 24 - 230 V 24 V= 7,3 VA /4,7 W LED CBU -30…+50°C 24 V=2 x 2,5 mm2 1,2
AC/DC 230 V=15,4 VA /5,3 W 230 V=3 x 2,5 mm2
-o-
| Viewing distance: 30 m | Light source: 9W 2G7 fluorescent tube or LED | Protection rating: IP65
EXIT LUMINAIRES
SELF-CONTAINED LUMINAIRES 850 °C
Product code Supply Max input power Light Operation Temperature Electrical Weight
voltage source mode range installation (kg)
TWT2901 Wall mounting reflector for TWT29 luminaires with 9 W fluorescent lamp
95
Teknoware Emergency Lighting Product Catalogue_T375
ESC 82 EN
60598-2-22
EN
1838
-o- IP
44
RAL
9003
CEILING
AND WALL
20 M MOUNTING
VIEWING AS
DISTANCE STANDARD
EASY TO
INSTALL
THANKS TO
A SEPARATE
MOUNTING
BASE
DIMENSIONS
350 4 4
125 160
125
93 60
93 86
350
96
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
| Viewing distance: 20 m | Light source: 8 W G5 or 8 W 2G7 fluorescent tube | Protection rating: IP44
EXIT LUMINAIRES
Product code Supply Max input power Light Operation Temperature Electrical installation Weight
voltage source mode range (kg)
ACCESSORIES
Product code Product
97
Teknoware Emergency Lighting Product Catalogue_T375
SAFE 29 EN
60598-2-22
-o- IP
65
RAL
9003
WALL AND
SURFACE
MOUNTING
Certified: AS STANDARD
• TWT2984K
DIMENSIONS
341
341 270
21
32
53
189 94 189
80
RECESS MOUNTING
WITH A SEPARATE FRAME
398
APERTURE FOR RECESS MOUNTING
350 MM X 215 MM
70
246
24
98
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
TWT2951WK 230 V 8,3 VA / 4,6 W LED 190 CBU / C -30…+50°C 3 x 2,5 mm2 1,2
AC/DC + IC -o-
TWT2971W 24 - 230 V 24 V= 7,3 VA /4,7 W LED 190 CBU -30…+50°C 24 V=2 x 2,5 mm2 1,2
AC/DC 230 V=15,4 VA /5,3 W 230 V=3 x 2,5 mm2
-o-
| Light source: 9W 2G7 or 18 W 2G11 or 8 W G5 fluorescent tube or LED | Protection rating: IP65
Product code Supply voltage Max input power Light Luminous Operation Temperature Electrical installation Weight
source flux (lm) mode range (kg)
TWT2953W 230 V 19,5 VA LED 160 3 h battery non-maintained 3 x 2,5 mm2 1,5
AC 0… +35°C -o-
TWS2992WAC 230 V 3,6 VA LED 120 1 h Escap + -25…+35°C 3 x 2,5 mm2 1,5
AC Aalto -o-
EMERGENCY LUMINAIRES
99
Teknoware Emergency Lighting Product Catalogue_T375
SAFE 29 EN
60598-2-22
-o- IP
65
RAL
9003
ACCESSORIES
Product code Product
208
60
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
4 5 6 15 3 4 5 7,5 14 8 4,5
TWT2984K TWT2984K
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
4 13 8 20 5 4 13 8,5 16 10 5,5
100
Teknoware Emergency Lighting Product Catalogue_T375
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
TWS2992WAB TWS2992WAC
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
!
NOT E
V ED
IMPRO MANCE
R
PERF O
EMERGENCY LUMINAIRES
101
Teknoware Emergency Lighting Product Catalogue_T375
SAFE 82 EN
60598-2-22
-o- IP
44
RAL
9003
CEILING EASY TO
AND WALL INSTALL
MOUNTING THANKS TO
AS A SEPARATE
STANDARD MOUNTING
BASE
DIMENSIONS
350 4 4
125 160
125
93 60
93 86
350
102
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
103
Teknoware Emergency Lighting Product Catalogue_T375
SAFE 82 EN
60598-2-22
-o- IP
44
RAL
9003
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
TWT8281K TWT8281K
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
2,5 14 5,2 12 5,2 2,5 14 6,5 10 7 6,5
4 5,5 6 16 6 4 5,5 8 14 8 8
TWT8284K TWT8284K
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
TWT8282 TWT8282
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
TWT8283 TWT8283
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
10 5 9 24 8 10 5 13,2 16 16 8,5
!
NOT E
V ED
IMPRO MANCE
R
PERF O
104
Teknoware Emergency Lighting Product Catalogue_T375
EMERGENCY LUMINAIRES
REFERENCES
105
Teknoware Emergency Lighting Product Catalogue_T375
SAFE 6 EN
60598-2-22
-o- LED IP
44
RAL
9003
CEILING,
WALL
AND FLAG
MOUNTING
AS
STANDARD
63 281
14
84
84
96
267
18 21 18 23
124
WALL MOUNTING
79
17
58
96
106
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
TWT0651WK 230 V 13 VA / 7,5 VA LED 350 CBU/C -30… 3 x 2,5 mm2 1,0
AC/DC (320 with lens set) + IC +50°C -o-
TWT0671W 24-230 V 24 V=9 VA / 8 W LED 350 CBU -30… 24 V=2 x 2,5 mm2 1,0
AC/DC 230 V=15 VA / 6,5 W (320 with lens set) +50°C 230 V=3 x 2,5 mm2
-o-
ACCESSORIES
Product code Product
109 81 58 43
268
66 Max.
1000mm
106
57
43
107
Teknoware Emergency Lighting Product Catalogue_T375
SAFE 6 EN
60598-2-22
-o- LED IP
44
RAL
9003
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
TWT0651WK, TWT0671W (luminaire with lens) TWT0651WK, TWT0671W (luminaire with lens)
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
TWT0681K TWT0681K
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
TWT0652WA, TWT0652WM (luminaire with lens) TWT0652WA, TWT0652WM (luminaire without separate lens)
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
6 3,6 5,5 13 1
108
Teknoware Emergency Lighting Product Catalogue_T375
REFERENCES
EMERGENCY LUMINAIRES
109
Teknoware Emergency Lighting Product Catalogue_T375
TRISPOT TWT75 & TWT76 EN
60598-2-22
-o- LED IP
20
RAL
9003
APERTURE
EMERGENCY LUMINAIRE FOR HIGH MOUNTING EMERGENCY LUMINAIRE FOR LOW AND OPEN AREAS
FOR
FOR
RECESS
MOUNTING
TWT75XX TWT76XX MOUNTING
Ø 60 MM
DIMENSIONS
290
60 48
70
290
70 55 277
57
21
4,5 35
58
58
55
55
57 57
2 2
70 70
110
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | =Colour of the body
RAL
9003
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
TWT7551WK TWT7551WK
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
8 23 6 13 6 8 23 5,5 10 10 5,5
TWT7651WK TWT7651WK
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
4 10 4,5 12 4,5 4 10 5 9 9 5
6 4,5 5 14 5 6 4,5 6 11 11 6
8 2,5 5 14 5 8 2,5 6 10 10 6
!
NOT E
V ED
IMPRO MANCE
R
PERF O
111
Teknoware Emergency Lighting Product Catalogue_T375
LINESPOT EN
60598-2-22
-o- LED IP
20
RAL
9003
APERTURE
FOR
FOR
RECESS
MOUNTING
MOUNTING
Ø 75 MM
Certified:
• TWT5051WK
Direction of the
light pattern Linespot, a recess mount emergency
luminaire utilising the latest LED technology,
is designed especially for illuminating high
corridors. The luminaire optics are designed
to produce a long and narrow field of light
which effectively illuminates emergency
escape routes and enables maximum spacing
between the luminaires.
Linespot’s small size and stylish design
make energy-efficient emergency lighting
possible without detracting from the general
appearance of the area.
DIMENSIONS
46
9 55
101
101
45 229 21 21 290
215 290 229 21
45 46 277
277 215
54
55 55
4,5 34 4,5 4,5
34 4,5 35
229
290 229 290
101
101 43 43 101
75 48
75
75
112
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
TWT5071W 24-230 V 24 V=7,5 VA / 4 W 170 CBU -30…+50°C 24 V=2 x 2,5 mm2 0,35
AC/DC 230 V=11 VA / 4 W 230 V=3 x 2,5 mm2
-o-
!
NOT E
h
V ED
IMPRO MANCE
R4
Y R1 R2
R
| R1 distance from wall (X axis )
X
PERF O
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
EMERGENCY LUMINAIRES
TWT5051WK, TWT5071W TWS5092W, TWS5092WM, TWS5092WA
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
6 5,6 6 18 1,5
8 3,1 5 18 1,5
10 2 4 16 1,5
2,5 14 3,5 8 1
4 5 5,5 11 1
6 2,5 6 14 1
113
Teknoware Emergency Lighting Product Catalogue_T375
ZONESPOT EN
60598-2-22
-o- LED IP
20
RAL
9003
APERTURE
RECESS FOR
MOUNTING MOUNTING
ONLY Ø 75 MM
DIMENSIONS
45 53
8
101
101
229 75 290
45 215 67 229 229 45 277
215 215
53 53
21 35
4,5 34 21
4,5
229 4,5 4,5 34
290
75
67
101 229 229 101
43
75 48
75
43
101
114
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | =Colour of the body
RAL
9003
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
TWT6471W 24-230 V 24 V=7,5 VA / 4 W 170 CBU -30…+50°C 24 V=3 x 2,5 mm2 0,35
AC/DC 230 V=11 VA / 4 W 230 V=3 x 2,5 mm2
-o-
SELF-CONTAINED LUMINAIRES
Product code Supply Input power Luminous Operation mode Temperature Electrical installation Weight
voltage flux (lm) range (kg)
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
EMERGENCY LUMINAIRES
2,5 14,7 3 7 3 2,5 14,7 3 6 6 3
6 2,6 4 11 4 6 2,6 5 10 10 5
TWT6452W, TWT6452WA, TWT6452WM, TWT6453WA, TWT6453WM TWT6452W, TWT6452WA, TWT6452WM, TWT6453WA, TWT6453WM
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
115
Teknoware Emergency Lighting Product Catalogue_T375
ZONESPOT II EN
60598-2-22
-o- LED IP
20
IP
44
RAL
9003
| IP20: Electronic unit, connectors and the recessed part of an installed luminaire
| IP44: The visible part of an installed luminaire
APERTURE
FOR
FOR
RECESS
MOUNTING
MOUNTING
Ø 75 MM
DIMENSIONS
TWT0451WK TWT0471W
290 35 229
34
277 215
100 50 45 50 45
21 21
4,5 4,5
290
229 43
75 48
75
116
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | =Colour of the body
RAL
9003
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
TWT0471W 24-230 V 24 V= 7,5 VA / 4 W 200 CBU -30…+50°C 24 V=3 x 2,5 mm2 0,35
AC/DC 230 V= 11 VA / 4 W 230 V=3 x 2,5 mm2
-o-
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
4 1,7 4 14 4 4 1,7 6 11 11 6
EMERGENCY LUMINAIRES
117
Teknoware Emergency Lighting Product Catalogue_T375
LINESPOT II EN
60598-2-22
-o- LED IP
20
RAL
9003
APERTURE
FOR
FOR
RECESS
MOUNTING
MOUNTING
Ø 75 MM
Direction of the
light pattern
Linespot II, a recess mount emergency
luminaire utilising the latest LED technology,
is designed especially for illuminating high
corridors. The luminaire optics are designed
to produce a long and narrow field of light
which effectively illuminates emergency
escape routes. The installation distance
between the luminaires can be up to 24 m.
Linespot II’s small size and stylish design
make energy-efficient emergency lighting
possible without detracting from the general
appearance of the area.
DIMENSIONS
TWT14751WK TWT1471W
290 35 229
34
277 215
100 50 45 50 45
21 21
4,5
4,5
290 229 43
100 100
| Aperture for mounting Ø 75 mm
75 48 75
118
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
R4
Y R1 R2
TWT1451WK, TWT1471W
Mounting Below the R1 (m) R2 (m) R4 (m)
height (m) luminaire lux
4 2,5 9 24 1
EMERGENCY LUMINAIRES
119
Teknoware Emergency Lighting Product Catalogue_T375
SLIMSPOT EN
60598-2-22
-o- LED IP
20
RAL
9003
FOR APERTURE
RECESS FOR
MOUNTING MOUNTING
Ø 75 MM
229
40 290
215 40 277
42 42
21 34 21
4,5
103 4,5 35
229
290
103 43 103
48
75 75
70 TWS9792WX TWS9792WX
290 190
42 277 160
40 42
103 44
2 103 4,5 4,5 40
2 42
44 103
48
75
103
120
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | =Colour of the body
RAL
9003
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
!
NOT E
V ED
IMPRO MANCE
R
LIGHT DISTRIBUTION TABLES PERF O
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux EMERGENCY LUMINAIRES
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
2,5 12 3,5 8 3,5 2,5 12 4 7 7 4
4 4,8 3,5 9 3,5 4 4,8 4 8 8 4
6 2 3,5 10 3,5 6 2 4 8 8 4
TWS9792WM/A TWS9792WM/A
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R4 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
2,5 1,6 1,4 4,4 1,4 2,5 1,6 2,7 3 3 2,7
121
Teknoware Emergency Lighting Product Catalogue_T375
LINESPOT EN
60598-2-22
-o- LED IP
20
RAL
9003
FOR
SURFACE
MOUNTING
DIMENSIONS
180
21
25
180 139
184 5,2
90
76
97
180
20
49 53
78 25
21
122
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | =Colour of the body
RAL
9003
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
R4
Y R1 R2
!
NOT E
V ED
X
IMPRO MANCE
EMERGENCY LUMINAIRES
| R1 distance from wall (X axis )
R
PERF O
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
4 12,5 6 15 2 4 5 5,5 11 1
8 3,1 5 18 1,5
TWS7892W, TWS7892WM, TWS7892WA
10 2 4 16 1,5
Mounting Below the R1 (m) R2 (m) R4 (m)
height (m) luminaire lux
2,5 7 2,5 7 1
4 2,8 2,5 7 1
123
Teknoware Emergency Lighting Product Catalogue_T375
ZONESPOT EN
60598-2-22
-o- LED IP
20
RAL
9003
FOR
SURFACE
MOUNTING
DIMENSIONS
180
21
25
180
139
184 5,2
90
76 97
180
20
49 53
78 25
21
124
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
TWT9471W 24-230 V 24 V=7,5 VA / 4 W 170 CBU -30…+50°C 24 V=2 x 2,5 mm2 0,65
AC/DC 230 V=11 VA / 4 W 230 V=3 x 2,5 mm2
-o-
EMERGENCY LUMINAIRES
Product code Product description
125
Teknoware Emergency Lighting Product Catalogue_T375
ZONESPOT EN
60598-2-22
-o- LED IP
20
RAL
9003
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
6 2,6 4 11 4 6 2,6 5 10 10 5
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
126
Teknoware Emergency Lighting Product Catalogue_T375
Department store Sokos Jyväskylä, Jyväskylä, Finland
127
Teknoware Emergency Lighting Product Catalogue_T375
MINI LINESPOT EN
60598-2-22
-o- LED IP
20
RAL
9003
FOR APERTURE
RECESS FOR SPOT
MOUNTING Ø 30 MM
29
DIMENSIONS
30
32
52
38
38
20
229 290
43 48
290
229 277
215 32
32
52 21 52 21
4,5 34 4,5
128
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
Product code Supply Max input power Luminous Operation mode Temperature Electrical installation Weight
voltage flux (lm) range (kg)
!
NOT E
V ED
h
R4
IMPRO MANCE
R
PERF O
Y R1 R2
TWT7371W, TWT7351WK
6 5,6 6 18 1,5
8 3,1 5 18 1,5
10 2 4 16 1,5
TWS7392W
2,5 7 2,5 7 1
4 2,8 2,5 7 1
129
Teknoware Emergency Lighting Product Catalogue_T375
SAFESPOT EN
60598-2-22
-o- LED IP
20
IP
44
RAL
9003
FOR
SURFACE
MOUNTING
DIMENSIONS
264 264
220
45 17
139 114
12 139 45
264
5,5
130
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
ACCESSORIES
SHOCK PROTECTING COVER
Product code Product
TW77508B
TWT4401 Gasket set for IP44 version
EMERGENCY LUMINAIRES
(dimensions: X=320, Y=165, Z=305, A=340)
131
Teknoware Emergency Lighting Product Catalogue_T375
SAFESPOT EN
60598-2-22
-o- LED IP
20
IP
44
RAL
9003
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
6 2,4 3 7 3 6 2,4 3 5 5 3
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
132
Teknoware Emergency Lighting Product Catalogue_T375
REFERENCES
EMERGENCY LUMINAIRES
133
Teknoware Emergency Lighting Product Catalogue_T375
SAFE 22 EN
60598-2-22
-o- IP
44
RAL
9003
FOR
SURFACE
SURFACE MOUNTING AND
RECESS
MOUNTING
RECESS MOUNTING
DIMENSIONS
196
21
256 21
20 31 119
270 59
105 25
46 270
5
34 39 27
134
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
ACCESSORIES
Product code Product
EMERGENCY LUMINAIRES
135
Teknoware Emergency Lighting Product Catalogue_T375
SAFE 22 EN
60598-2-22
-o- IP
44
RAL
9003
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
TWT2281K TWT2281K
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
TWT2284K TWT2284K
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
6 6 5,5 15 5,5 6 6 6 11 11 6
8 3,4 5 16 5 8 3,4 6 11 11 6
TWT2282 TWT2282
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
TWT2283 TWT2283
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
136
Teknoware Emergency Lighting Product Catalogue_T375
Kind Saud University, Jeddah, Saudi Arabia
REFERENCES
EMERGENCY LUMINAIRES
137
Teknoware Emergency Lighting Product Catalogue_T375
DOWNLIGHT EN
60598-2-22
-o- IP
20
RAL
9003
APERTURE
FOR FOR RECESS
RECESS MOUNTING
MOUNTING Ø 185 MM
DIMENSIONS
189 362
169 21
15 46 58
51
82 91 78 91 21
196 9
196
185
161
189
326
362
138
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | =Colour of the body
RAL
9003
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
EMERGENCY LUMINAIRES
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
TW95681K TW95681K
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
4 8 4 10 4 4 8 4 7 7 4
6 3 5 12 5 6 3 4,5 9 9 4,5
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
139
Teknoware Emergency Lighting Product Catalogue_T375
TWT58 EN
60598-2-22
-o- IP
20
RAL
9003
RECESS
MOUNTING
ONLY
Certified:
• TWT5881K
DIMENSIONS
35
21 4,5 75
61
100
30 270
391
351 75
88 80 88 9
140
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | =Colour of the body
RAL
9003
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
TWT5881K TWT5881K
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
2,5 17 3,5 8 3,5 2,5 17 3 5 5 3
4 6,7 4,5 10 4,5 4 6,7 4 7 7 4
6 3 4,5 12 4,5 6 3 4 7 7 4
8 1,7 4 13 4 8 1,7 4,5 8 8 4,5
EMERGENCY LUMINAIRES
141
Teknoware Emergency Lighting Product Catalogue_T375
TWK41 /42 EN
60598-2-22
-o- IP
20
RAL
9003
Certified:
• TWK4181K
• TWK4281K
4,5 156 21
380 5 25
21 26
29
82
85 111
67 30
52 288
270 351
353
353 81
85 351 24
41
84 84
82 89 21
5 5 111
380
89
111
351
142
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | =Colour of the body
RAL
9003
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
Emergency lighting for escape routes (ceiling mounting) Emergency lighting for open areas (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Table of 0,5 lux for open areas according to the norm EN 1838,
| Level of measurement 0,02 m, measurement result with battery operation 0,5 m edge district is considered in the table.
| Level of measurement 0,02 m, measurement result with battery operation.
R4 R4 h
Y R1 R2
R3
X
Y R1 R2
X
| R1 distance from wall (X axis ) | R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis)
| R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)
TWK4181K TWK4181K
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
EMERGENCY LUMINAIRES
2,5 9,9 3,3 8 3,3 2,5 9,9 3,5 6 6 3,5
TWK4281K TWK4281K
Mounting Below the R1 (m) R2 (m) R4 (m) Mounting Below the R1 (m) R2 (m) R3 (m) R4 (m)
height (m) luminaire lux height (m) luminaire lux
1 lux 1 lux 1 lux 0,5 lux 0,5 lux 0,5 lux 0,5 lux
2,5 5 3 7 4 2,5 5 4 7 7 4
4 2,2 3 8 4 4 2,2 4 7 7 4
143
Teknoware Emergency Lighting Product Catalogue_T375
HANDRAIL LUMINAIRE EN
60598-2-22
-o- IP
65
RAL
9003
RECESSED
TO A PIPE-
RAILING
MOUNTING
DIMENSIONS
144
Teknoware Emergency Lighting Product Catalogue_T375
| |
=Protection class of luminaire is 1 =Protection class of luminaire is 2 | =Protection class of luminaire is 3 | IP20 = Protection rating | RAL
9003=Colour of the body
| CBU = Centrally supplied | -o- =Luminaire is suitable for through-wiring | IC= Compatible with Intelligent Controller
| Escap = Self-Contained luminaire with 1 h super capacitor backup | C = Compatible with Tapsa Control Central Battery Units | 850 °C =compliant with the 850 glow wire test
| Aalto = Aalto Control compatible (incl. Lumi Test) | M = Self-contained luminaire with Lumi Test self-testing | LED =LED as a light source
EMERGENCY LUMINAIRES
145
Teknoware Emergency Lighting Product Catalogue_T375
SHOCK PROTECTING COVERS
| Shock protecting covers are used in e.g. sports halls, gymnasiums and stadiums to protect luminaires (against e.g. ball)
X Y Z A
146
Teknoware Emergency Lighting Product Catalogue_T375
REFERENCES
147
Teknoware Emergency Lighting Product Catalogue_T375
FREQUENTLY ASKED QUESTIONS
WHAT DO THE FOLLOWING SYMBOLS AND ABBREVIATIONS MEAN IN TEKNOWARE PRODUCT CATALOGUE?
=The product conforms with the essential EN =Verified photometric data on the luminaire available according to
requirements of the applicable EC directives. 60598-2-22 standard EN60598-2-22
EN =Central battery unit include all the basic functions required by the
LED =LED as a light source
50171 EN50171 standard.
RAL RAL
=Colour of the luminaire body =Colour of the luminaire body (RAL 9006 =grey)
9003 9006
(RAL 9003 =white)
Protection classes
Class I The protection is provided by a combination of basic insulation and the use of electrical earth.
Class II Double-insulated electrical products which comprise both basic insulation and supplementary insulation
Class III Luminaires are designed to be supplied from a special safety isolating transformer whose output is known as Safety Extra-Low Voltage or SELV
IP
IP-classification xx
Degree of protection against solid foreign objects (1st number) Protection against
0 Non-protected
5 Dust-protected
6 Dust-tight
0 Non-protected
148
Teknoware Emergency Lighting Product Catalogue_T375
FREQUENTLY ASKED QUESTIONS
Question: Why emergency lighting is needed? Question: Is the pictogram fixed into the Question: What kind of battery cabinet do I
luminaire need?
Answer: Emergency lighting is mandatory
in workplaces and public buildings. Answer: Pictogram will be fixed into the Answer: It depends on the batteries. You will
Emergency lighting makes possible luminaire in our production unless find the tables of battery cabinets on
the safe ending of working and customer asks pictogram to be every central battery unit page at the
evacuation of the building in case of packed separately. Separately packed beginning of this product catalogue.
an emergency. pictograms customer has to paste /
Question: Which one of the battery cables is
fix by oneself. Sometimes label needs
Question: Is there a minimum order quantity? correct for my system?
to be cut for the shape. Taping labels
Answer: No, you can order just one luminaire, into the luminaire cover is included Answer: Battery cable will be determined
but there is a fee for small delivery. in the price of the luminaire, when based on the batteries. You will
Extra handling fee is 100€ for a pictogram is bought together with the find the tables of battery cables on
shipment of an order under 250€. exit luminaire.. every central battery unit page at the
beginning of this product catalogue.
Question: How fast can I get products? Question: Which is the life time of LED
luminaire? Question: Where can I find Eulumdat light
Answer: Typical delivery time for the products
distribution files?
in the catalogue is two to three (2-3) Answer: Life time of LED luminaire is normally
weeks (Ex-works) from the written 8-10 years, when luminaire is situated Answer: Eulumdat light distribution files for the
order, but faster delivery is also often in normal room temperature. Dialux Software are on Teknoware
possible depending on the product, web pages.
Question: What kind of central battery unit do
capacity of our production, and the
I need?
amount of the products you want to
order. Delivery date will be confirmed Answer: It depends on the size of the central
with the order confirmation battery unit you will need, if you need
an addressable or a non-addressable
Question: Can I have luminaires in other
system, how many circuits there
colours than in white or grey (which
should be, how many and what kind
are basic colours for Teknoware
of emergency and exit luminaires will
luminaires)?
be used in the system and should it
Answer: Yes, almost all the luminaires can be work in 24 V or 230 V system.
painted in RAL colours (there will be
Question: How do I calculate what kind of
extra charge of painting).
batteries I need for the Central
Question: Do I need to to buy a pictogram for battery unit?
exit luminaire??
Answer: You have to calculate the total Max
Answer: Pictogram needs to be bought input power of all the (exit and
always separately for exit luminaires. emergency) luminaires is the system
Direction of the arrow needs to be (total load / central battery unit).
informed in the order, pictogram can
Question: Do I need a battery cabinet or
be a label or light plate depending
battery cables?
on the luminaire. There are so called
multifunction labels for some exit Answer: It depends on the central battery
luminaires. You can choose the figure unit and size of the batteries. If you
by yourself and remove the parts need a separate battery cabinet you
of the label with e.g. a knife. With will also need a battery cable. Some
light plates you have to know the central battery units have space for
direction of arrow, because there is no batteries, and there is no need for a
multifunction figure available. separate battery cabinet. For example,
there is space for 2 x 38 Ah batteries
in TK2301-04 central battery units,
bigger than 38 Ah batteries need a
separate battery cabinet.
149
Teknoware Emergency Lighting Product Catalogue_T375
TERMS & CONDITIONS
| If not otherwise agreed, we quote the following terms and conditions.
Delivery time The delivery time is confirmed for each order with the order confirmation. Typically it is two-three weeks (Ex-works) from written order.
Luminaires Pictogram needs to be ordered always separately. Pictogram will be pasted into the exit luminaire cover at the factory without extra fee. If
pictogram is wanted to be separately packed, it needs to be clearly informed in the order. Emergency luminaire includes EMERGENCY
LUMINAIRE label in the package.
Delay interest 8%. Interest of delayed payments will be determined according to Directive 2000/35/EC of the European Parliament and of the Council
of 29 June 2000. Teknoware Oy retains full ownership of the goods until the invoices have totally been paid. Prior hereto, buyers cannot
transfer ownership to anyone.
Other terms Other terms according to orgalime supply conditions, August 2000; no other compensations can be demanded.
150
Teknoware Emergency Lighting Product Catalogue_T375
CONTACT INFORMATION
Teknoware Middle East FZCO. Find us on social media:
LIU H12
Dubai Airport Freezone
Dubai
UAE
Tel: +9714 2993622
Fax: +9714 2993623
info@teknoware.ae
www.teknoware.ae
151
Teknoware Emergency Lighting Product Catalogue_T375
CONTENTS
Product code Page Product code Page Product code Page
152
Teknoware Emergency Lighting Product Catalogue_T375
Product code Page Product code Page Product code Page
153
Teknoware Emergency Lighting Product Catalogue_T375
CONTENTS
Product code Page Product code Page Product code Page
154
Teknoware Emergency Lighting Product Catalogue_T375
NOTES
155
Teknoware Emergency Lighting Product Catalogue_T375
TEKNOWARE 4
CENTRAL MONITORING 41
CONTENTS 152
Teknoware Middle East FZCO Teknoware Oy
LIU H12 Ilmarisentie 8
Dubai Airport Freezone FI-15200 LAHTI
Dubai FINLAND
UAE
Tel. +358 3 883 020
Tel: +9714 2993622 Fax +358 3 883 0260
Fax: +9714 2993623
info@teknoware.ae emexit@teknoware.fi
T375 / 1 / 14