NON - CONFORMANCE REPORT


NCR No.: NCR/J9/32 Date: 24 -10-2009

Stage: Incoming / Inprocess / Final / Customer Complaint

Customer / Supplier Name : Asil Process Name & No. Job No : 74


Engineering Supplier DC No:1575 31/08/2009

Part No./Rev: 190660-001 / B Part Name : Adjuster

Total Qty. : 1412 Nos. NCR Qty. : 250 Nos.


SL. No. Feature Inspected Non-Conformance Identified

1. 7/8" 20UNEF -2B Thread Gauge Nogo Pass .

Root Cause :

Action Plan Target Date

Disposition Action : Stock Qty 1000 Nos. Segreged by SPF and found 250 nos.

Approx. Value 10687/-


Quorantined
Accepted Rejected Rework Concession
(Hold)

Prepared by: Arthur Premkumar Approved by : Sundar.D

Name: Name: