DYC INTERNATIONAL

INSPECTION VISIT REPORT


IVR-DYC.M.1.22.0004-Sr.No. 41– Rev 00

General
Date(s) of Expediting /
DYC Control No. DYC.M.1.22.0004 18.10.2023
Inspection
Plot No. 1118 Kalamboli
Notification Name / Expediting / Inspection
By Email Dtd. 17.10.2023 Steel Yard,
Number Location
Kalamboli,
Larsen And Toubro –
Project Name & Location: S010560A End User Name Heavy Engineering Vertical,
Surat, Gujarat
Larsen And Toubro –
DYC Client Name Heavy Engineering Vendor Name & Location M/s. Kaarlo Metal & Tubes
Vertical , Surat, Gujarat.
P.O. Number (Client PO 01 L016252 dtd..
PMC/EPC Name --------
on Vendor ) 11.10.2023
Stages
Kick off / Pre-Inspection
In process Stages Final Inspection
Meeting
Document Review Re-Inspection Expediting
Item Description
P.O. Qty.- Offered Acceptable
PO. Item No. Item Code Item Description
mtr. Qty. Mtr. Qty. Mtr.
S010560- Refer Area Of
1 PIPE 2 INCH x SCH. 160, SA 106 - Gr B 30 32.89
A0101 concern)
S010560- Refer Area Of
2 PIPE 6 INCH x SCH. 160, SA-106 - GR B 48 51.47
A0102 concern)
Reference Documents
Client PO Document Client Document Vendor Document
Sr. No. Approval Status
Number Name Number Number
PR / MR /
1 101801 Not Applicable Approved
ARM
01 L016252 dtd..
2 Drawings Not Applicable Not Applicable Not Applicable
11.10.2023
QAP / ITP /
3 Not Applicable Not Applicable Not Applicable
QCP
Inspection Activities Carried Out:
Stages Witnessed:
Field Inspection
1 Visual & Dimensional –
a) PIPE 2 INCH x SCH. 160, SA 106 - Gr B – 5 Nos.
b) PIPE 6 INCH x SCH. 160, SA-106 - GR B – 8 Nos.
• 100 % Visual inspection carried out for PO qty. 100% of external surface and accessible area of inside
surface verified & found satisfactory during inspection.
• 10 % Dimension inspection carried out for PO line items & found within tolerance limit as per
specification/standards.
2 Manufacturers marking (Manufacturer Logo, Material grade, Heat No, Size) verification has been carried out on
the 10% of offered pipes with reference to MTC provided by the vendor, Marking found satisfactory as per
specification/standard
3 Provisional stamping done on pipes subjected to acceptance on area of concern.
Document Review:
1. Material Test Certificate (Type EN 10204 Type 3.1 & Well Know Pipe Maker Form IIIA) for Pipes is reviewed &
verified with original test certificates and found as per applicable ARM (101,801) & specification / standard

Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,
Website: www.dycintl.com Page 1 of 6 Ref. No: DYC-IR-01 Rev.0
DYC INTERNATIONAL
INSPECTION VISIT REPORT
IVR-DYC.M.1.22.0004-Sr.No. 41– Rev 00

2. Traceability verified with calibration certificates of measuring Instruments used during inspection found
satisfactory.
3. Photocopy of calibration certificate reviewed found in order.
Conclusion: Inspection was carried out within the defined scope defined as per ARM (101,801). The items have met
all the requirements of the PO , ARM & Specification. Acceptance subjected to closure of area of concern.
Pending Activities – Final Packing
Identification of the Inspected Items– All Pipes provisionally hard stamped as " " (single) on Pipe OD near
manufacturer's marking.
Areas of Concern:
1. In 2 “ x SCH. 160 – SA 106 Gr B pipes during marking correlating with MTC additional marking of “ P.O
P.O.NO.54 LOT A SR. NO. “ observed on pipe. Vendor to take clarification from manufacturer.
2. In 2 “ x SCH. 160 & 6 “ x SCH. 160 – SA 106 Gr B pipes alignment of marking is not align straight. Vendor to
take clarification from manufacturer.
3. As per ARM 801- Heat Treatment is specified however all pipes are hot finished as per MTC.L&T to confirm
acceptance.
4. In 6 “ x SCH. 160 – SA 106 Gr B- 2 Nos. pipes founded grinded from inside, however thickness survey and
visual inspection throughout length is not possible due to non-availability of Utrasonic thickness gauge (Dmeter)
and boroscope.
Non-Conformities raised / Discrepancies observed during Inspection – NIL
Enclosure: Inspection Records
Authorized Signatures
DYC Inspectors: Vendor / Sub Vendor Representative:

Name: Prasad Kore Date: 18.10.2023

Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,
Website: www.dycintl.com Page 2 of 6 Ref. No: DYC-IR-01 Rev.0
DYC INTERNATIONAL
INSPECTION VISIT REPORT
IVR-DYC.M.1.22.0004-Sr.No. 41– Rev 00

Inspection Photographs

Offered Quantity of Pipes Offered Quantity of Pipes

Dimensional Inspection of Pipes Dimensional Inspection of Pipes

Dimensional Inspection of Pipes Dimensional Inspection of Pipes

Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,
Website: www.dycintl.com Page 3 of 6 Ref. No: DYC-IR-01 Rev.0
DYC INTERNATIONAL
INSPECTION VISIT REPORT
IVR-DYC.M.1.22.0004-Sr.No. 41– Rev 00

Inspection Photographs

Dimensional Inspection of Pipes Dimensional Inspection of Pipes

Dimensional Inspection of Pipes Dimensional Inspection of Pipes

Accessible Inside Visual Inspection of Pipes Accessible Inside Visual Inspection of Pipes

Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,
Website: www.dycintl.com Page 4 of 6 Ref. No: DYC-IR-01 Rev.0
DYC INTERNATIONAL
INSPECTION VISIT REPORT
IVR-DYC.M.1.22.0004-Sr.No. 41– Rev 00

Inspection Photographs

Internal Grinded Surface of pipe as per Area of Concern –


Marking Verification on Pipes
Sr. No.4

Marking Verification on Pipes DYC identification on Pipes

DYC identification on Pipes DYC identification on Pipes

Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,
Website: www.dycintl.com Page 5 of 6 Ref. No: DYC-IR-01 Rev.0
DYC INTERNATIONAL
INSPECTION VISIT REPORT
IVR-DYC.M.1.22.0004-Sr.No. 41– Rev 00

Inspection Photographs

Zigzag marking on pipe as per Area of Concern – Zigzag marking on pipe as per Area of Concern –
Sr. No.2 Sr. No.2

Addition marking on pipe as per Area of Concern –


Calibration Traceability of Measuring Instruments
Sr. No.1

----N/A----

Calibration Traceability of Measuring Instruments

Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,
Website: www.dycintl.com Page 6 of 6 Ref. No: DYC-IR-01 Rev.0