General
Date(s) of Expediting /
DYC Control No. DYC.M.1.22.0004 18.10.2023
Inspection
Plot No. 1118 Kalamboli
Notification Name / Expediting / Inspection
By Email Dtd. 17.10.2023 Steel Yard,
Number Location
Kalamboli,
Larsen And Toubro –
Project Name & Location: S010560A End User Name Heavy Engineering Vertical,
Surat, Gujarat
Larsen And Toubro –
DYC Client Name Heavy Engineering Vendor Name & Location M/s. Kaarlo Metal & Tubes
Vertical , Surat, Gujarat.
P.O. Number (Client PO 01 L016252 dtd..
PMC/EPC Name --------
on Vendor ) 11.10.2023
Stages
Kick off / Pre-Inspection
In process Stages Final Inspection
Meeting
Document Review Re-Inspection Expediting
Item Description
P.O. Qty.- Offered Acceptable
PO. Item No. Item Code Item Description
mtr. Qty. Mtr. Qty. Mtr.
S010560- Refer Area Of
1 PIPE 2 INCH x SCH. 160, SA 106 - Gr B 30 32.89
A0101 concern)
S010560- Refer Area Of
2 PIPE 6 INCH x SCH. 160, SA-106 - GR B 48 51.47
A0102 concern)
Reference Documents
Client PO Document Client Document Vendor Document
Sr. No. Approval Status
Number Name Number Number
PR / MR /
1 101801 Not Applicable Approved
ARM
01 L016252 dtd..
2 Drawings Not Applicable Not Applicable Not Applicable
11.10.2023
QAP / ITP /
3 Not Applicable Not Applicable Not Applicable
QCP
Inspection Activities Carried Out:
Stages Witnessed:
Field Inspection
1 Visual & Dimensional –
a) PIPE 2 INCH x SCH. 160, SA 106 - Gr B – 5 Nos.
b) PIPE 6 INCH x SCH. 160, SA-106 - GR B – 8 Nos.
• 100 % Visual inspection carried out for PO qty. 100% of external surface and accessible area of inside
surface verified & found satisfactory during inspection.
• 10 % Dimension inspection carried out for PO line items & found within tolerance limit as per
specification/standards.
2 Manufacturers marking (Manufacturer Logo, Material grade, Heat No, Size) verification has been carried out on
the 10% of offered pipes with reference to MTC provided by the vendor, Marking found satisfactory as per
specification/standard
3 Provisional stamping done on pipes subjected to acceptance on area of concern.
Document Review:
1. Material Test Certificate (Type EN 10204 Type 3.1 & Well Know Pipe Maker Form IIIA) for Pipes is reviewed &
verified with original test certificates and found as per applicable ARM (101,801) & specification / standard
Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,
Website: www.dycintl.com Page 1 of 6 Ref. No: DYC-IR-01 Rev.0
DYC INTERNATIONAL
INSPECTION VISIT REPORT
IVR-DYC.M.1.22.0004-Sr.No. 41– Rev 00
2. Traceability verified with calibration certificates of measuring Instruments used during inspection found
satisfactory.
3. Photocopy of calibration certificate reviewed found in order.
Conclusion: Inspection was carried out within the defined scope defined as per ARM (101,801). The items have met
all the requirements of the PO , ARM & Specification. Acceptance subjected to closure of area of concern.
Pending Activities – Final Packing
Identification of the Inspected Items– All Pipes provisionally hard stamped as " " (single) on Pipe OD near
manufacturer's marking.
Areas of Concern:
1. In 2 “ x SCH. 160 – SA 106 Gr B pipes during marking correlating with MTC additional marking of “ P.O
P.O.NO.54 LOT A SR. NO. “ observed on pipe. Vendor to take clarification from manufacturer.
2. In 2 “ x SCH. 160 & 6 “ x SCH. 160 – SA 106 Gr B pipes alignment of marking is not align straight. Vendor to
take clarification from manufacturer.
3. As per ARM 801- Heat Treatment is specified however all pipes are hot finished as per MTC.L&T to confirm
acceptance.
4. In 6 “ x SCH. 160 – SA 106 Gr B- 2 Nos. pipes founded grinded from inside, however thickness survey and
visual inspection throughout length is not possible due to non-availability of Utrasonic thickness gauge (Dmeter)
and boroscope.
Non-Conformities raised / Discrepancies observed during Inspection – NIL
Enclosure: Inspection Records
Authorized Signatures
DYC Inspectors: Vendor / Sub Vendor Representative:
Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,
Website: www.dycintl.com Page 2 of 6 Ref. No: DYC-IR-01 Rev.0
DYC INTERNATIONAL
INSPECTION VISIT REPORT
IVR-DYC.M.1.22.0004-Sr.No. 41– Rev 00
Inspection Photographs
Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,
Website: www.dycintl.com Page 3 of 6 Ref. No: DYC-IR-01 Rev.0
DYC INTERNATIONAL
INSPECTION VISIT REPORT
IVR-DYC.M.1.22.0004-Sr.No. 41– Rev 00
Inspection Photographs
Accessible Inside Visual Inspection of Pipes Accessible Inside Visual Inspection of Pipes
Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,
Website: www.dycintl.com Page 4 of 6 Ref. No: DYC-IR-01 Rev.0
DYC INTERNATIONAL
INSPECTION VISIT REPORT
IVR-DYC.M.1.22.0004-Sr.No. 41– Rev 00
Inspection Photographs
Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,
Website: www.dycintl.com Page 5 of 6 Ref. No: DYC-IR-01 Rev.0
DYC INTERNATIONAL
INSPECTION VISIT REPORT
IVR-DYC.M.1.22.0004-Sr.No. 41– Rev 00
Inspection Photographs
Zigzag marking on pipe as per Area of Concern – Zigzag marking on pipe as per Area of Concern –
Sr. No.2 Sr. No.2
----N/A----
Address: Shop No.1, Rachna Neeraj C.H.S Ltd Lokmanya Tilak Road, Near Nakhwa High School, Thane East
400603.Maharashtra, India. Contact: +91 8433657700 / 8779640055. E-Mail: parag.wadekar15@gmail.com,