Fresh Air Intake Kit

We are pleased to announce that Fresh Air Intake Kit will be added to line of Single &
Multi split system and VRF system. This kit is one of the options for the line up of cassette
type indoor units. Fresh air is mixed with room air then pass through a heat exchanger.

Model NO. : UTZ-VXAA (For compact cassette type indoor unit )


UTZ-VXGA (For cassette type indoor unit )

UTZ-VXAA UTZ-VXGA

Installation example
Standard Indoor unit Cassette type attached Fresh Air
Intake Kit

Under the roof


Outside
Room
Panel
Outlet air Room air Outlet air

Case1:Intake by fan of indoor unit


Connecting duct Panel
(Field supplied)
Fresh Air
Intake Kit Indoor unit Connecting duct
(Field supplied)
Fresh air

Outlet air Room air Outlet air

Case2:Intake by duct fan


Connecting duct
(Field supplied)
Fresh Air
Intake Kit Fresh Air Intake Kit
Fresh air

Room air Duct fan (Field supplied)


Outlet air Outlet air
1. Features
- It can be taken in fresh air of up to 10% of “high” air volume of the indoor unit by
attaching Fresh Air Intake Kit to cassette type indoor unit.

2. Performance
1) UTZ-VXAA

Applicable indoor unit : (XUR.assetteEPRGHOO

- Installation place and dimensions

(Unit: mm)

Chamber

- Air flow volume – Static pressure of Fresh Air Intake Kit characteristic
It indicates characteristic between the chamber Inlet and the indoor unit inlet.
UTZ-VXAA (Compact cassette) - Note
UTZ-VXAA for Compact cassette type
1. When installing this kit, inspection hatch is necessary.
(It is necessary when servicing.)
Static pressure of Fresh air intake kit [Pa]

200

2. In case of mounting a duct fan, it interlocks an air-


conditioner and its operation is performed
Static pressure of Fresh air intake kit [Pa]

150 simultaneously with the air conditioner’s fan(see P05).


3. The intake air flow volume is recommended to be 10%
or less of the High speed air flow volume. If the intake
100 air flow volume is too large, the operating sound may
rise or detection of the indoor temperature may be
affected.
50 4. Permissible ranges of temperature is as follows:
Outdoor temperature: 0℃ or more.
5. Connecting duct is field supply.
0
6. Measurement position is shown above fig.
0 50 100 150 200
3 7. Fresh air intake volume may not be sufficient depending
Air flow [m /h]
Air flow rate [m3/h]
on the regulation of each country. In that case, please
use energy recovery ventilator at the same time.

2
2) UTZ-VXGA

Applicable indoor unit :.assetteQPRGHOO (IODFK)

- Installation place and dimensions


(Unit: mm)

(Unit: mm)

[Measurement position of shown in the graph]

- Air flow volume – Static pressure of Fresh Air Intake Kit characteristic
It indicates characteristic between the T-tube inlet and the indoor unit inlet
when the T-tube is connected.

UTZ-VXGA (Cassette
UTZ-VXGA for Cassette type type) - Note
150
1. When installing this kit, inspection hatch is necessary.
(It is necessary when servicing.) Either one of
Static pressure of Fresh air intake kit [Pa]

inspection hatches must be installed.


Static pressure of Fresh air intake kit [Pa]

2. In case of mounting a duct fan, it interlocks an air-


100 conditioner and its operation is performed
1-Way Intake simultaneously with the air conditioner’s fan (see P05).
3. The intake air flow volume is recommended to be 10%
or less of the High speed air flow volume. If the intake
50 air flow volume is too large, the operating sound may
2-Way Intake
rise or detection of the indoor temperature may be
affected.
4. Permissible ranges of temperature is as follows:
0 Outdoor temperature: 0℃ or more.
0 50 100 150 200 250 300 350 400
Air flow
Air flow rate[m
3
/h]
[m3/h]
5. T-tube and connecting duct are field supply.
6. Measurement position is shown above fig.
7. Fresh air intake volume may not be sufficient depending
on the regulation of each country. In that case, please
use energy recovery ventilator at the same time.

3
Applicable indoor unit :.assetteQPRGHOO (VWDQGDUG)

- Installation place and dimensions


(Unit: mm)

[Measurement position of shown in the graph]

- Air flow volume – Static pressure of Fresh Air Intake Kit characteristic
It indicates characteristic between the T-tube inlet and the indoor unit inlet
when the T-tube is connected.
- Note
UTZ-VXGA (Cassette
UTZ-VXGA for Cassette type type) 1. When installing this kit, inspection hatch is necessary.
150 (It is necessary when servicing.) Either one of
inspection hatches must be installed.
Static pressure of Fresh air intake kit [Pa]

2. In case of mounting a duct fan, it interlocks an air-


Static pressure of Fresh air intake kit [Pa]

conditioner and its operation is performed


100 simultaneously with the air conditioner’s fan (see P05).
1-Way Intake 3. The intake air flow volume is recommended to be 10%
or less of the High speed air flow volume. If the intake
air flow volume is too large, the operating sound may
50 rise or detection of the indoor temperature may be
2-Way Intake
affected.
4. Permissible ranges of temperature is as follows:
Outdoor temperature: 0℃ or more.
0 5. T-tube and connecting duct are field supply.
0 50 100 150 200 250 300 350 400
Air flow
Air flow rate[m
3
/h]
[m3/h] 6. Measurement position is shown above fig.
7. Fresh air intake volume may not be sufficient depending
on the regulation of each country. In that case, please
use energy recovery ventilator at the same time.

3. Fresh air control output


- You can control duct fan by synchronization with fan operation of indoor unit.
- Wire for fresh air control output is supplied with Fresh Air Intake Kit.
- Extended length of the wire : For Single & Multi split system :Max. 25m
For VRF system :Max 150m
- External output specification is the same in Single & Multi and VRF though the
connection method is different.

4
1) For Single & Multi split system

Connection diagram
・For Relay Output voltage : DC 12V ±2V
Permissible current :15mA

Relay
Wire
Indoor 1
unit 2
CN6
Field supplied

Indoor unit status


Operation
Indoor
unit fan
Stop

12V
CN6
Output
0V

Wire (Fresh air output)


Wire color: RED

Wire color: WHITE

2) For VRF system


Connection diagram
- For Relay Output voltage : DC 12 – 24V
Permissible current : 30mA
Power supply Relay
Wire
1 + + DC12V
- -
Indoor 2
unit 3
4 -
Field supplied
CN16

Indoor unit status


Operation
Indoor
unit fan
Stop

12-24V
CN16(1-4)
Output
0V

Wire (Fresh air output)


Wire color: RED

Wire color: WHITE

5
4, Specifications

1) For Single & Multi split system

Model name UTZ-VXAA UTZ-VXGA


Compact cassette type Cassette type
Applicable model name
AU*F AU*F AU*F AU*F AU*F AU*F AU*A AU*A AU*A AU*A
(Representative model)
09LAL 12LAL 14LAL 18LBL 22LBL 24LBL 30LBL 36LB(C) 45LCL 54LCL
Fan speed of Airflow 3
High m /h 540 610 700 800 1030 1030 1600 1800 1900 2000
indoor unit rate
3
Fresh air Max fresh air m /h 54 61 70 80 103 103 160 180 190 200
intake intake volume
% (for high) 10% 10%

Connection mm φ100 φ100


Duct type Pcs 1 2
Dimensions Net 570 x 570 x 120 840 x 840 x 120
mm
( H×W×D) Gross 585 x 585 x 165 860 x 860 x 165
Net 3.5 5.5
Weight kg
Gross 5.5 9.0
Chamber x 1 , Wire cover x 1 , Screw x 4 , Duct flange x 2 , Cover x 2 , Screw x 16 ,
Binder x 1 , Extension wire for louver x 2 , Hook plate x 4 , Shutter plate x 1 ,
Extension wire for recieving x 1 , Insulation ①x 2 , Insulation ②x 1 ,Binder x 1 ,
Accessory parts Wire (external output ①) x 1 , Extension wire for louver x 2 ,
Wire (external output ②) x 1 , Bolt x 4 Extension wire for reciever kit x 1 ,
Wire(external output ①) x 1 ,
Wire(external output ②) x 1

2) For VRF system

Model name UTZ-VXAA UTZ-VXGA


Compact cassette type Cassette type
Applicable model name
AUXB AUXB AUXB AUXB AUXB AUXB AUXD AUXD AUXA AUXA AUXA AUXA
(Representative model) 07LALH 09LALH 12LALH 14LALH 18LALH 24LALH 18LALH 24LALH 30LALH 36LALH 45LALH 54LALH

Fan speed of Airflow 3


High m /h 540 550 600 680 710 1030 1150 1280 1600 1800 1900 2000
indoor unit rate
3
Fresh air Max fresh air m /h 54 55 60 68 71 103 115 128 160 180 190 200
intake intake volume
% (for high) 10% 10%

Connection mm φ100 φ100


Duct type Pcs 1 2
Dimensions Net 570 x 570 x 120 840 x 840 x 120
mm
( H×W×D) Gross 585 x 585 x 165 860 x 860 x 165
Net 3.5 5.5
Weight kg
Gross 5.5 9.0
Chamber x 1 , Wire cover x 1 , Screw x 4 , Duct flange x 2 , Cover x 2 , Screw x 16 ,
Binder x 1 , Extension wire for louver x 2 , Hook plate x 4 , Shutter plate x 1 ,
Extension wire for recieving x 1 , Insulation ①x 2 , Insulation ②x 1 ,Binder x 1 ,
Accessory parts Wire (external output ①) x 1 , Extension wire for louver x 2 ,
Wire (external output ②) x 1 , Bolt x 4 Extension wire for reciever kit x 1 ,
Wire(external output ①) x 1 ,
Wire(external output ②) x 1

6
5, Accessory parts

1) UTZ-VXAA
Extention Extention Wire Wire
Parts name Chamber Wire cover Screw wire for wire for (External (External Bolt
louver reciever kit output①) output②)

Exterior

Air joint for Cover for Fixing for Extension wire Extension wire For connect For connect For fixing
connection extension wire chamber for louver for receiving indoor unit to indoor unit to Fresh air
duct Fixing for wire reley of duct reley of duct intake kit to
Description cover fan fan indoor unit
(For Single & (For VRF)
Multi)

pcs 1 1 4 2 1 1 1 4

2) UTZ-VXGA
Parts name Duct flange Cover Screw Hook plate Shutter plate Insulation① Insulation② Binder

Exterior

Air joint for Protective For fixing duct Plate for fixing Shutter plate Affixing the Affixing the Fixing the
connection cover to flange panel for 1-way insulation insulation to tube of drain
duct prevent dew For fixing intake outside of the the tube of pump wire
condensation cover kit drain pump
Description on surface wire for
prevent dew
condensation

pcs 2 2 16 4 1 2 1 1

Extension Extension Wire Wire


Parts name wire for wire for (External (External Bolt
louver reciever kit output①) output②)

Exterior

Extension wire Extension To connect To connect For fixing


for louver wire for indoor unit to indoor unit to Fresh air
reciever kit reley of duct reley of duct intake kit to
Description fan (for Single fan (for VRF) indoor unit
& Multi)

pcs 2 1 1 1 4