We are pleased to announce that Fresh Air Intake Kit will be added to line of Single &
Multi split system and VRF system. This kit is one of the options for the line up of cassette
type indoor units. Fresh air is mixed with room air then pass through a heat exchanger.
UTZ-VXAA UTZ-VXGA
Installation example
Standard Indoor unit Cassette type attached Fresh Air
Intake Kit
2. Performance
1) UTZ-VXAA
(Unit: mm)
Chamber
- Air flow volume – Static pressure of Fresh Air Intake Kit characteristic
It indicates characteristic between the chamber Inlet and the indoor unit inlet.
UTZ-VXAA (Compact cassette) - Note
UTZ-VXAA for Compact cassette type
1. When installing this kit, inspection hatch is necessary.
(It is necessary when servicing.)
Static pressure of Fresh air intake kit [Pa]
200
2
2) UTZ-VXGA
(Unit: mm)
- Air flow volume – Static pressure of Fresh Air Intake Kit characteristic
It indicates characteristic between the T-tube inlet and the indoor unit inlet
when the T-tube is connected.
UTZ-VXGA (Cassette
UTZ-VXGA for Cassette type type) - Note
150
1. When installing this kit, inspection hatch is necessary.
(It is necessary when servicing.) Either one of
Static pressure of Fresh air intake kit [Pa]
3
Applicable indoor unit :.assetteQPRGHOO (VWDQGDUG)
- Air flow volume – Static pressure of Fresh Air Intake Kit characteristic
It indicates characteristic between the T-tube inlet and the indoor unit inlet
when the T-tube is connected.
- Note
UTZ-VXGA (Cassette
UTZ-VXGA for Cassette type type) 1. When installing this kit, inspection hatch is necessary.
150 (It is necessary when servicing.) Either one of
inspection hatches must be installed.
Static pressure of Fresh air intake kit [Pa]
4
1) For Single & Multi split system
Connection diagram
・For Relay Output voltage : DC 12V ±2V
Permissible current :15mA
Relay
Wire
Indoor 1
unit 2
CN6
Field supplied
12V
CN6
Output
0V
12-24V
CN16(1-4)
Output
0V
5
4, Specifications
6
5, Accessory parts
1) UTZ-VXAA
Extention Extention Wire Wire
Parts name Chamber Wire cover Screw wire for wire for (External (External Bolt
louver reciever kit output①) output②)
Exterior
Air joint for Cover for Fixing for Extension wire Extension wire For connect For connect For fixing
connection extension wire chamber for louver for receiving indoor unit to indoor unit to Fresh air
duct Fixing for wire reley of duct reley of duct intake kit to
Description cover fan fan indoor unit
(For Single & (For VRF)
Multi)
pcs 1 1 4 2 1 1 1 4
2) UTZ-VXGA
Parts name Duct flange Cover Screw Hook plate Shutter plate Insulation① Insulation② Binder
Exterior
Air joint for Protective For fixing duct Plate for fixing Shutter plate Affixing the Affixing the Fixing the
connection cover to flange panel for 1-way insulation insulation to tube of drain
duct prevent dew For fixing intake outside of the the tube of pump wire
condensation cover kit drain pump
Description on surface wire for
prevent dew
condensation
pcs 2 2 16 4 1 2 1 1
Exterior
pcs 2 1 1 1 4