Contract n. 5000010298
Distrib. Category: PR10
Vendor logo and business name Vendor Document ID
6202-SP-0057-D
Contract: 71259C-001-200-CS-3626-0001
this document was obtained from COMPANY and CONTRACTOR bases of design and project
specifications. This document is to supplement documentation packages to be issued to the TMS
vendors and fabricators.
Document Verification
A. Maslov
Review
REVISION LIST
EX-DE_00 Issue for Comment
EX-DE_01 Issue for Approval
Issue for Approval
Table 2.2: Added superscripts to m3
Section 4: Added HOLD for confirmation on Scaler Inhibitor design pressure.
EX-DE_02 Section 4.1: Corrected Reference number
Section 4.1: Removed 40%wt MEG characteristics and properties.
Section 4.2: Corrected Reference number
Section 5: Added Utility Swivel tag
Issue for Final
Section 4: Remove HOLD 1 from Scale Inhibitor design pressure on Table 4
EX-DE_03
Section 4: Add Note 1 to Table 4 to differentiate the PSV set point and the piping/equipment
design pressure
HOLD RECORD
BEGINNING OF HOLDS LIST (DO NOT MODIFY OR REMOVE THIS LINE)
Contents
INTRODUCTION ........................................................................................................................................ 5
BACKGROUND ............................................................................................................................... 5
PROJECT LOCATION ..................................................................................................................... 5
COMPANY JOINT VENTURE INFORMATION............................................................................... 6
PROJECT OBJECTIVE ................................................................................................................... 6
SCOPE OF THE DOCUMENT ......................................................................................................... 6
REFERENCES ................................................................................................................................. 6
1.6.1 Order of Precedence ..................................................................................................................... 6
1.6.2 COMPANY Documents ................................................................................................................. 6
1.6.3 CONTRACTOR Documents .......................................................................................................... 6
1.6.4 TMS SUBCONTRACTOR Documents .......................................................................................... 7
ACRONYMS AND ABBREVIATIONS ............................................................................................. 7
INTRODUCTION
BACKGROUND
The Area 4 Offshore Rovuma Basin block, with an initial area of 17,646 km 2, was awarded to the Area 4 Joint
Venture, for which Eni East Africa S.p.A. (EEA) was appointed as the Operator on December 2006 (with
effective date February 2007).
It is located in the deep waters of the Rovuma Basin (1500 to 2300 WD) and straddles the Mozambique’s
Northern border with Tanzania, adjacent to the Area 1 block. The Rovuma Basin is part of the Tanzania-
Mozambique Coastal Basin, which has a total extension of some 80,000 km2 and a maximum thickness of
about 10 km.
PROJECT LOCATION
Area 4 is situated approximately 250 km North East of Pemba and 50 km from the coastline, measured from
the western limit of the concession; the Block is about 70 km wide by 200 km long. Currently Area 4 covers a
surface of 10207 sqkm.
EEA is the Operator of the Area 4 Block (with a 70% participation interest), with the other participants being
ENH (10% carried throughout the exploration phase), Galp Energia (10%) and Kogas (10%). CNPC holds a
28.57% participation in EEA (equal to an indirect participation of 20% in the Block).
PROJECT OBJECTIVE
Coral South Development Project has the objective to exploit the southern portion of Coral non-straddling
reservoir through one Floating LNG (FLNG) Unit, and relevant subsea development.
The scope of this document is to describe the composition of the process fluids which will be imported to the
FLNG Facility within the Turret.
REFERENCES
Should any conflicts arise between the documents defining requirements for the project, the following listed
order of priority shall prevail; as defined in document 71259C010-200-CSD-3626-0001 Rev. 01. The list is
provided here for convenience only, and is subservient to the contract.
1. Mozambique National Laws and Regulations,
2. Lloyds Register & Flag Requirements (rev. July 2014),
3. COMPANY Basis of Design document Ref. 440400BGRB00013_Rev.02,
4. CONTRACTOR documents,
5. FEED documents contained in Exhibit K,
6. Applicable COMPANY Standards
7. International Codes and Standards,
8. TMS SUBCONTRACTOR Standards.
CONTRACTOR COMPANY
Document Title
Document No. Document No.
1. Basis of Design NA 440400BGRB00013 Rev. 03
CONTRACTOR COMPANY
Document Title
Document No. Document No.
2. Engineering Design Basis 71259C-0100-PP-0203 4404GGBGPD0012T Rev. 04
071259C010-000-CSE-3626- N/A
3. SUBCONTRACT - EXHIBIT E - rev. 1
0001
TMS
CONTRACTOR COMPANY
Document Title SUBCONTRACTOR
Document No. Document No.
Document No.
TMS - Process Technical 71259C-001-200-CS-
5. 6202-DR-0008 4404UUDTRA215S2
Description 3626-0001
TMS - Piping System - Design 71259C-0400-STD-
6. 6201-DB-0105 4404UUDTRB150S4
Basis 1300-S001
UNITS OF MEASUREMENT
The units of measurement will be generally expressed according to S.I. except for any differences in the
following table:
The following table lists the design and operating pressures and temperatures of the incoming produced gas
stream.
The maximum design flow rate and the design case are (Ref. [3], Section 7):
Case Flowrate Description
LELO 605 MMSCFD Design Lean Low
The above total flow rates are through four to six flow lines.
Maximum design gas flowrate is 150 MMScf/d per well / flowline and the correspondent flowrate of liquids
(water and condensate) (Ref. [1] Section 8.3.3).
FEEDSTOCK CHARACTERISTICS
The pseudo component properties are provided in Appendices G and H of Basis of Design (Ref [1]).
CONTAMINANTS DATA
SAND PRODUCTION
The above provided values have to be considered as normal operation values. The sand production reported
in the table above is to be considered valid at the top of the tubing. The above values are obtained from Section
8.4 of Basis of Design. Ref. [1]
In addition to the produced fluid system listed above, the turret will also contain chemical services. MEG
Injection (both to subsea and Turret) and Scale Inhibitor Injection are both provided from topsides. The
following table lists the design pressures and temperatures of the chemical services being delivered from
topsides (Ref. [6] Section 9).
NOTE 1: PSV set point at discharge of scale inhibitor pump is 176 barg.
The 90%wt MEG characteristics are as follows (Ref [4], Table 4-2):
Scale inhibitors are water soluble products and the ranges of viscosity and density values are
reported as follows (Ref [4], Table 7-1):
Sample 2⁰ C 20⁰ C
Viscosity S.C (cP) 3.0 – 7.8 1.9 – 4.4
Density (g/cm 3) 1.10 – 1.11 1.09 – 1.11
Table 4.2: Scale Inhibitor Properties