ProductInformation

Preparation of
crown cores | Sonic Tips
Exact positioning and finishing of crown margins with sonic tips

In crown restorations, an exact margi- This is followed by the exact position-


nal seal is of utmost importance for the ing of the preparation limit for the
long-term success of a preparation and prosthetic marginal seal by means of
a clinically perfect result. A combination the sonic tip SF847KR.000.016. The
of rotary instruments for the preparation final finishing is carried out with the
of crown cores and congruent sonic same sonic tip at minimum setting.
tips is predestined for this indication.
In close collaboration with a renowned When used in combination with the
specialist from Milan, Dr. Domenico KaVo SONICflex system, the sonic tips
Massironi, who kindly provided his do not only achieve excellent finished
expert advice, Komet have developed results, they also leave the gums com-
sonic tips especially designed for this pletely unharmed, even if direct contact
area of application. occurs. A sonically placed and finished
crown margin is the best precondition
The dentist can choose from the shapes for an exact impression and the success-
“ellipse” (SF979), “tapered with rounded ful creation of a durable restoration.
edge” (SF847KR) and “flame” (SF862).
In order to for example prepare a shoul-
der to receive an all-ceramic restora-
tion, a supra-gingival preparation is
carried out with a rotary instrument
(847KR.314.016).
Application Recommendations for use:

1. – 2. Supra-gingival preparation with 1 2 • The tips are used in the KaVo


a rotary instrument. The replica of the SONICflex system only. The operat-
core – obtained by impression taking – ing frequency is 6 ± 0,5 kHz, the
shows parallel grooves created by the oscillating range is 0.10 – 0.15 mm.
rotary preparation.
• The positioning of the crown margin
3. – 4. Exact positioning of the prepara- is carried out at setting 2, the finish-
tion limit by means of the congruent ing process at setting 1.
sonic instrument. The corresponding
replica displays an irregular surface • Always supply sufficient spray
structure, which favours the perfect 3 4 cooling (at least 30 – 50 ml when
impregnation and adhesion of the fixa- working with sonic instruments).
tion cement.

5. The finished preparation shows


no damage to the soft tissue.

6. Ceramic crown in place.

5 6

Best synergy effects are achieved


by using a combination of sonic and
rotary instruments.

2979.314.014 6862.314.014 6847KR.314.016