You are on page 1of 52

GRUNDFOS DATA BOOKLET

Grundfos Basic
50 Hz
Contents

JPBasic CHBasic PS
Performance range Page 3 General data Page 26
General data Page 4 Applications Page 26
Applications Page 4 Constructional features Page 26
Constructional features Page 4 Material specification Page 26
Material specification Page 5 Technical data Page 27
Technical data Page 5 Curve conditions Page 27
Curve conditions Page 5
CHBasic PC
JPBasic PT
General data Page 28
General data Page 10 Applications Page 28
Applications Page 10 Operation Page 28
Constructional features Page 10 Constructional features Page 28
Material specification Page 10 Material specification Page 29
Technical data Page 11 Technical data Page 30
Curve conditions Page 30
JPBasic PS
NSBasic
General data Page 12
Performance range Page 31
General data Page 32
JPBasic PC NSBasic single impeller pumps Page 32
General data Page 13 Applications Page 32
Applications Page 13 Constructional features Page 32
Operation Page 13 Material specification Page 32
Technical data Page 15 Technical data Page 33
NSBasic twin impeller pumps Page 35
Applications Page 35
JDBasic Constructional features Page 35
Material specification Page 35
General data Page 16
Technical data Page 36
Applications Page 16
Constructional features Page 16
Material specification Page 16 KPBasic
Technical data Page 17
Instructions for conversion Page 18 Performance range Page 39
General data Page 40
Applications Page 40
CHBasic Constructional features Page 40
Technical data Page 41
Performance range Page 19
Curve conditions Page 41
General data Page 20
Applications Page 20
Constructional features Page 20 PFBasic
Material specification Page 20
Technical data Page 21 Performance range Page 44
Curve conditions Page 21 General data Page 45
Applications Page 45
Constructional features Page 45
CHBasic PT Material specification Page 45
Technical data Page 46
General data Page 24
Applications Page 24
Constructional features Page 24 PFPBasic
Material specification Page 24
Technical data Page 25 General data Page 47
Curve conditions Page 25 Applications Page 47
Constructional features Page 47
Materials Page 47
Technical data Page 48

2
JPBasic JPBasic

Performance range
p H
[kPa] [m]
JPBasic
65 50 Hz
600
60

55

500
50

45

400
40
5

35 7

300 30
10

25 4
9

200 20 3

15
2

100 10

0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
TM02 8936 1804

0.0 0.5 1.0 1.5 2.0 2.5 3.0 Q [l/s]

3
JPBasic General data

JPBasic 2, JPBasic 3, JPBasic 4 JPBasic 9, JPBasic 10

Gr7903

Gr7921
Applications JPBasic 5, JPBasic 7
Self-priming centrifugal pump with excellent suction
capacity even when there are air bubbles and small
sandy impurities in the water.
Used especially for supplying water to domestic
systems. Ideal for use in small-scale agriculture and
gardening, limited industrial services and wherever self-
priming operation is necessary.

Constructional features
Pump
Cast iron pump body and motor support in cast iron
treated against corrosion also on the inner surface.

Gr7917
Technopolymer impeller, diffuser venturi tube and sand
tube. Stainless steel pressure disc. Carbon/ceramic
mechanical seal mounted on stainless steel rotor shaft
extension.
Motor
Asynchronous motor cooled with external fan. Rotor
mounted on greased sealed-for-life ball bearings,
selected to ensure silent running and a long life.
Built-in thermal and current overload protection and a
capacitor permanently in circuit in the single-phase
version.
The user is responsible for protection in the three-phase
version.
Motor protection: IP 44
Terminal box protection: IP 55
Insulation class: F
Standard voltage: 1 x 220-240 V, 50 Hz
3 x 220-240/380-415 V, 50 Hz.

4
JPBasic Technical data

Material specification
Pos. Description Material
8 1 6 28 3
1 Pump body Cast iron EN-GJL-200
3 Support Cast iron EN-GJL-200
4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9 *
Venturi tube and
8 Noryl GFN 2
nozzle
16 Mechanical seal Carbon/Ceramic

TM02 8459 0204


28 O-Ring gasket NBR
* JPBasic 1, JPBasic 2, JPBasic 4: X 12 Cr S 13

16 4 7

Technical data
Operating range: From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth: 8 metres
Maximum operating pressure: JPBasic 2, JPBasic 3, JPBasic 4: 6 bar (600 kPa)
JPBasic 5, JPBasic 7, JPBasic 9, JPBasic 10: 7.5 bar (750 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.

5
Technical data JPBasic

JPBasic 2
0 2 4 6 8 10 12 Q [US GPM]
A
A1
C 0 2 4 6 8 10 Q [IMP GPM]
DNM P H
H
DNA

[kPa] [m]
[ft]
400 40
120
35
320

H
30 100
H3

240 25 80

TM02 8444 0204


20
60
E F I 160 8
15 5
G 7 6 4 3 2 40
B 10
80
5 20

0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [m³/h]

TM02 9023 1304


Electrical data 0.0 0.2 0.4 0.6 Q [l/s]

Pump type P1 P2 P2 In Capacitor


Voltage [V] Max. 0 10 20 30 40 Q [l/min]
[kW] [kW] [hp] [A] [µF] [Vc]
1 x 220-240 0.72 0.44 0.6 3.12 12.5 450
JPBasic 2
3 x 220-240/380-415 0.67 0.44 0.6 2.1/1.2 - -

Packing dimensions
Pump Dimensions [mm] Vol Weight
[mm]
type [m3] [kg]
A A1 B C E F G H H3 I DNA DNM L/A L/B L/H
JPBasic 2 395 390 178 108 192 14 111 200 144 9 Rp 1 Rp 1 470 240 240 0.027 10.9

JPBasic 3
0 2 4 6 8 10 12 14 Q [US GPM]
A
A1
C 0 2 4 6 8 10 Q [IMP GPM]
DNM P H
H
DNA

[kPa] [m]
[ft]
45
140
400 40
120
35
H

320
H3

30 100

25
TM02 8444 0204

240 80
20 8
E F I 7 60
G 160 15 6 5 4 3
B 2 40
10
80
5 20

0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [m³/h]
TM02 9024 1304

Electrical data 0.0 0.2 0.4 0.6 0.8 Q [l/s]

Pump P1 P2 P2 In Capacitor
type Voltage [V] Max. 0 10 20 30 40 50 Q [l/min]
[kW] [kW] [hp] [A] [µF] [Vc]
1 x 220-240 0.85 0.6 0.8 3.8 12.5 450
JPBasic 3
3 x 220-240/380-415 0.86 0.6 0.8 2.8/1.6 - -

Packing dimensions
Pump Dimensions [mm] Vol Weight
[mm]
type [m3] [kg]
A A1 B C E F G H H3 I DNA DNM L/A L/B L/H
JPBasic 3 395 390 178 108 192 14 111 200 144 9 Rp 1 Rp 1 470 240 240 0.027 11

6
Technical data JPBasic

JPBasic 4
0 2 4 6 8 10 12 14 Q [US GPM]
A
A1
C 0 2 4 6 8 10 Q [IMP GPM]
DNM P H H
DNA

[kPa] [m] [ft]


50 160
45
140
400 40

H
120
35
H3

300 30 100

TM02 8444 0204


25 80
8 7
E F I 200 20
G 6 5 60
4 2
15 3
B 40
100 10
5 20

0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [m³/h]

TM02 9025 1304


Electrical data 0.0 0.2 0.4 0.6 0.8 Q [l/s]

Pump type P1 P2 P2 In Capacitor


Voltage [V] Max. 0 10 20 30 40 50 Q [l/min]
[kW] [kW] [hp] [A] [µF] [Vc]
1 x 220-240 1.13 0.75 1 5.1 16 450
JPBasic 4
3 x 220-240/380-415 1.04 0.75 1 3.3/1.9 - -

Packing dimensions
Pump Dimensions [mm] Vol Weight
[mm]
type [m3] [kg]
A A1 B C E F G H H3 I DNA DNM L/A L/B L/H
JPBasic 4 414 409 178 108 197 14 111 213 144 9 Rp 1 Rp 1 470 240 240 0.027 16.2

JPBasic 9
0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]
A
C
0 4 8 12 16 20 24 28 32 36 40 Q [IMP GPM]
DNA

P H
[kPa] [m] H
[ft]
400 40
120
35
H
H1

300 30 100

25 80
TM02 8464 0204

E F Iø 200 20
G 60
B 15
40
100 10
8
7 6 20
5 5 4
3
2 1
0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
TM02 9028 1304

Electrical data 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [l/s]

Pump P1 P2 P2 In Capacitor
type Voltage [V] Max. 0 20 40 60 80 100 120 140 160 180Q [l/min]
[kW] [kW] [hp] [A] [µF] [Vc]
1 x 220-240 2 1.5 2 9 31.5 450
JPBasic 9 3 x 220-240/
2 1.5 2 6.8/3.9 - -
380-415

Packing dimensions
Pump Dimensions [mm] Vol Weight
[mm]
type [m3] [kg]
A B C E F G Iø H H1 DNA DNM L/A L/B L/H
JPBasic 9 521 214 151 282 20 160 11 227 175 Rp 1 ½ Rp 1 ¼ 612 248 279 0.042 27

7
Technical data JPBasic

JPBasic 10
0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]
A
A1
C
0 4 8 12 16 20 24 28 32 36 40 Q [IMP GPM]
P H H
DNM [kPa] [m]
DNA

[ft]
50 160
45
140
400 40

H
120
H3

35
300 30 100

TM02 8464 0204


25 80
E F I 8
G 200 20
60
B 15
40
100 10 7
6 3 2 1 20
5 5 4
0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]

TM02 9029 1304


Electrical data 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [l/s]

Pump P1 P2 P2 In Capacitor
type Voltage [V] Max. 0 20 40 60 80 100 120 140 160 180Q [l/min]
[kW] [kW] [hp] [A] [µF] [Vc]
1 x 220-240 2.7 2.2 3 12 40 450
JPBasic 10 3 x 220-240/
2.7 2.2 3 8.5/4.9 - -
380-415

Packing dimensions
Pump Dimensions [mm] Vol Weight
[mm]
type [m3] [kg]
A B C E F G IØ H H1 DNA DNM L/A L/B L/H
JPBasic 10 595 214 151 282 20 160 11 235 175 Rp 1 ½ Rp 1 ¼ 657 248 279 0.045 31.5

JPBasic 5
0 2 4 6 8 10 12 14 16 18 20 Q [US GPM]

Z A B
C 0 2 4 6 8 10 12 14 16 Q [IMP GPM]
DNM P H
[kPa] [m] H
[ft]
600 60 200
DNA

V
500 50
H

160
H
DNE

400
H1

H2

40
120
H1

TM02 8462 0204

6
Iø 300 30 8
X 7 5 4
A E G 80
200 20 3
2
1
40
100 10

0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [m³/h]
TM02 9026 1304

Electrical data 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Q [l/s]

Pump P1 P2 P2 In Capacitor
type Voltage [V] Max. 0 10 20 30 40 50 60 70 Q [l/min]
[kW] [kW] [hp] [A] [µF] [Vc]
1 x 220-240 1.6 1.1 1.5 7.2 31.5 450
JPBasic 5 3 x 220-240/
1.6 1.1 1.5 5.2/3.0 - -
380-415

Packing dimensions
Pump Dimensions [mm] Vol Weight
[mm]
type [m3] [kg]
A B C E F G Iø H H1 DNA DNM L/A L/B L/H
JPBasic 5 558 210 221 350 20 145 11 255 158 Rp 1 ¼ Rp 1 612 248 279 0.045 31

8
Technical data JPBasic

JPBasic 7
0 4 8 12 16 20 24 28 32 Q [US GPM]

Z A B
C 0 4 8 12 16 20 24 28 Q [IMP GPM]
DNM P H
[kPa] [m] H
[ft]
600 60 200
DNA

V
500
H

50 160
H
DNE
H1

400

H2
40 8

H1
120

TM02 8462 0204


7
6
Iø 300 30
X 5 4
A E G 80
3 2
200 20

40
100 10
1
0 0 0
0 1 2 3 4 5 6 7 Q [m³/h]

TM02 9027 1304


Electrical data 0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]
Pump P1 P2 P2 In Capacitor
type Voltage [V] Max. 0 20 40 60 80 100 120 Q [l/min]
[kW] [kW] [hp] [A] [µF] [Vc]
1 x 220-240 2.2 1.85 2.5 10 40 450
JPBasic 7 3 x 220-240/
2.2 1.85 2.5 6.9/4.0 - -
380-415

Packing dimensions
Pump Dimensions [mm] Vol Weight
[mm]
type [m3] [kg]
A B C E F G Iø H H1 DNA DNM L/A L/B L/H
JPBasic 7 632 210 221 350 20 145 11 255 158 Rp 1 ¼ Rp 1 657 248 279 0.045 35

9
JPBasic PT General data

JPBasic PT Tank
Horizontal type, capacity 19 litres, with butyl
diaphragm, complete with feet on the bottom and
brackets for fixing the pump on top.

8 1 6 28 3

TM02 9060 1704General data

TM02 8459 3204


16 4 7

Applications Material specification


Automatic water lifting and pressure boosting sets, Pos. Description  Material
particularly suitable for domestic use, small installa- 1 Pump body Cast iron (EN-GJL-200)
tions for civil, industrial and agricultural use, washing 3 Support Cast iron (EN-GJL-200)
systems and hobbies. 4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
The characteristics of the JPBasic-pumps are that they
Stainless steel AISI 416
are self-priming electric pumps which can operate even 7 Shaft
X12 CrS 13
when there is air, gas and small quantities of sand in the 8 Venturi tupe and nozzle Noryl GFN 2
water. 16 Mechanical seal Carbon/Ceramic
The set is composed of a diaphragm tank with capacity 28 O-Ring gasket NBR
19 litres, pressure switch for automatic operation, pres- Components in contact with the liquid.
sure gauge, JPBasic electric pump complete with power
cable and plug, kit for coupling the pump and the tank,
all assembled and ready for installation.
Note: Vertical 8 litres or 18 litres tanks are used in some
markets.

Constructional features
Pump
Cast iron pump body and motor support.
Technopolymer impeller, diffuser, Venturi tube and sand
guard.
Stainless steel pressure discs.
Carbon/ceramic mechanical seal.
Motor
Induction motor, closed and cooled with external venti-
lation. Rotor mounted on oversized greased sealed-for-
life ball bearings, to ensure silent running and a long life.
Built-in thermal and current overload protection and a
capacitor permanently in circuit.
Manufactured according to standard EN 60335-2-41.
Motor protection: IP 44
Insulation class: F
Standard voltage: 1 x 220-240 V, 50 Hz.

10
JPBasic PT Technical data

Technical data
Operating range: Up to 3.6 m3/h with head up to 51 metres.
Liquid quality requirements: Clean, free from solids or abrasive substances, non viscous, non aggressive,
non crystallized, chemically neutral, close to the characteristics of water.
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum operating pressure: 6 bar (600 kPa)
Installation: Fixed in a horizontal position.

JPBasic PT
A1 D
0 2 4 6 8 10 12 14 Q [US GPM]

0 2 4 6 8 10 Q [IMP GPM]
H1

P H H
[kPa] [m] [ft]
50 160
45
JPBasic 2 140
400 40
JPBasic 3 120
35
JPBasic 4
300 100
H

30
TM02 9068 1704

25 80
200 20
60
15
40
A B 100 10
5 20
L
0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [m³/h]
0.0 0.2 0.4 0.6 0.8 Q [l/s]

TM02 8940 1704


Electrical data
0 10 20 30 40 50 Q [l/min]
Pump type P1 P1 In Capacitor
Voltage [V] Max.
[kW] [hp] [A] [µF] [Vc]
JPBasic 2 PT 1 x 220-240 0.72 0.44 3.12 12.5 450
JPBasic 3 PT 1 x 220-240 0.85 0.6 3.8 12.5 450
JPBasic 4 PT 1 x 220-240 1.13 0.75 5.1 16 450

Dimensions [mm] Packing dimensions [mm] Vol Weight


Pump type DNA DNM
A A1 B D H H1 L L/A L/B L/H [m3] [kg]
JPBasic 2 PT 550 390 270 282 290 232 332 Rp 1 Rp 1 576 366 554 0.107 16.1
JPBasic 3 PT 550 390 270 282 290 232 332 Rp 1 Rp 1 576 366 554 0.107 16.2
JPBasic 4 PT 550 409 270 282 290 232 332 Rp 1 Rp 1 576 366 554 0.107 21.4

11
JPBasic PS General data

JPBasic PS
Auto pressure units
Single-phase version:
Self-priming centrifugal pump equipped with pressure
gauge, pressure switch (PS), power supply cable with
plug and three-way brass connector for connecting to a
tank.

JPBasic-PS

Gr7908

Electrical data
Pump type P1 P2 P2 In Capacitor
Voltage [V] Max. Max.
[kW] [kW] [hp] [A] [µF] [Vc]
JPBasic 2 PS 1 x 220-240 0.72 0.44 0.6 3.12 12.5 450
JPBasic 3 PS 1 x 220-240 0.85 0.6 0.8 3.8 12.5 450
JPBasic 4 PS 1 x 220-240 1.13 0.75 1.0 5.1 16 450
JPBasic 5 PS 1 x 220-240 1.6 1.1 1.5 7.2 31.5 450

Packing dimensions
Dimensions [mm] Vol Weight
Pump type DNA DNM [mm]
[m3] [kg]
A A1 B C D E F G Iø H H1 H2 H3 I L/A L/B L/H
JPBasic 2 PS 395 390 282 108 196 192 14 111 - 232 199 200 144 9 Rp 1 Rp 1 486 366 232 0.041 11.9
JPBasic 3 PS 395 390 282 108 196 192 14 111 - 232 199 200 144 9 Rp 1 Rp 1 486 366 232 0.041 12.1
JPBasic 4 PS 414 390 282 108 196 192 14 111 - 232 199 - 144 9 Rp 1 Rp 1 486 366 232 0.041 13.9
JPBasic 5 PS 563 556 217 160 109 329 15 145 11 312 279 221 159 - Rp 1 ¼ Rp 1 600 236 267 0.038 31.5

12
JPBasic PC General data

JPBasic PC
Self-priming centrifugal pump equipped with presscon-
trol (PC) and power supply cable.

Gr7907

Applications
Automatic water lifting sets, particulary suitable for
domestic use, small installations for civil, industrial and
agricultural use, washing systems and hobbies.
These are characterised by the use of JPBasic PC self-
priming centrifugal pumps which can operate even
when there is air, gas and small quantities of sand in the
water.
They are indispensable for use in artesian wells and
whereever suction difficulties arise.

Operation
The pump is equipped with a Presscontrol (PC) which
controls, manages and commands it, regulating its oper-
ation, limiting the number of starts and guaranteeing
maximum pressure stability inside the hydraulic circuit
in which it is installed.
The automatic devices is the result of a series of studies
conducted to optimise the efficiency of the system while
preserving the structural features and sturdiness of
existent devices.
Automatic sets differ from the traditional systems
equipped with a pressure switch based on pump starting
and stopping as they avoid sudden variations and drops
in pressure. They are basically equipped with a double
control device, as built-in electrical circuit gathers the
data regarding pressure and water flow in the system
and processes them to allow the pump to operate under
optimum performance conditions.
The automatic device is supplied pre-installed on the
pump, requires no type of regulation and considerably
reduces overall dimensions by totally eliminating the
bulky tanks used traditional installations.

13
JPBasic PC General data

Optimised management of the hydraulic Constructional features of the pump


installation and its components JPBasic 3 PC, JPBasic 4 PC:
1. Enables the system to operate only when there is wa- Cast iron pump body and motor support treated against
ter present; if, for any reason, no water reaches the corrosion also on the inner surface. Technopolymer
system, it blocks the pump, so that it does not oper- impeller, diffuser and Venturi tube. Stainless steel pres-
ate while dry. In this case the ALARM LED lights up. sure discs and rotor shaft. Carbon/ceramic mechanical
2. Maintains pump operation when the appliances are seal.
opened by one or more users, in order to prevent sud-
Constructional features of the motor
den changes in pressure. When an appliance is
opened the depression created in the system acts on Induction motor, closed and cooled with external venti-
the membrane which gradually releases a spring. The lation. Rotor mounted on greased sealed-for-life ball
sensors detect the movement, send a signal to the bearings. Built-in thermal and current oyerload protec-
electronic unit which enables pump start-up. tion and a capacitor permanently in circuit.
3. Automatically stops the pump when the users stop Manufactured according to standard EN 60335-2-41.
drawing water. When the appliances are closed, un- Motor protection: IP 44
der the effect of the rise in pressure within the hy- Insulation class: F.
draulic system, the membrane totally compresses the
All the pumps are supplied with 0.75 metres of power
spring. This new situation is analysed by the sensors
cable type H05 RN-F with plug.
which send the unit a signal to stop the pump. The
stop is timed in order to prevent the pump from be- Constructional features of the automatic control
ing subjected to repeated starts caused by users
opening and closing the appliances within a few sec- The automatic device which regulates the pump opera-
onds of each other. Furthermore, if boilers are sup- tion is basically formed of the following components:
plied, the continuous delivery of hot water is FLOW SWITCH SET: this comprises a 4-way metal union
guaranteed by timing the stops. with two housings for the delivery and pressure sensors.
4. Instant pump start when one of the appliances is Both their seat and the sensor capsule are structured so
opened even with a minimum amount of water that no pre-calibration is required.
drawn. SPRING EXPANSION TANK: manufactured in pressed and
5. In the event of leaks in the system (drips or small flanged stainless steel, this has been designed to ensure
trickles) the device limits the number of cycles, pro- maximum reliability and sturdiness with minimum
longing pump running time by about 10 seconds. overall dimensions. Inside it houses a spring which oper-
6. It eliminates water hammering by means of a spe- ates as a pressure switch.
cific shock absorber which absorbs the effect. ELECTRONIC CARD: this is composed of a printed circuit
7. Manual reset in the event of a breakdown in the hy- which receives signals from the sensors and manages
draulic circuit or of overload protector intervention; the automatic device as indicated in the paragraph
in this case, after eliminating the cause, press the regarding operation. The commands plate with the two
"RESET" button positioned on the terminal board LEDs, green = ON, red = Alarm and the Reset button for
cover for a few seconds until the "ALARM" LED resetting the pump is positioned on the terminal board
switches off. cover.
8. In the event of a power cut, automatic reset as soon CHECK DEVICE: all automatic sets are equipped with a
as the power is restored. check valve which has been selected to ensure
9. The system is self-protected against overheating. maximum long lasting reliability. In order to prevent
When there is an excess in temperature inside the operational faults in the system it is essential that the
motor windings, this operation is carried out auto- position of the valve is not changed during assembly.
matically. It is also restored automatically once the The automatic control is supplied pre-assembled with all
temperature has dropped below the level which the accessories.
guarantees operation without damage to the system.

14
JPBasic PC Technical data

Technical data
Operating range: From 0.3 to 3.6 m3/h with head up to 51 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum operating pressure: 6 bar (600 kPa)
Installation: Fixed in a horizontal position.

JPBasic PC
C
DNM 0 2 4 6 8 10 12 14 Q [US GPM]

0 2 4 6 8 10 Q [IMP GPM]
P H H
[kPa] [m] [ft]
50 160
45
JPBasic 2 140
DNA

400 40
H

JPBasic 3 120
35
JPBasic 4
300 30 100
25 80
H3

TM02 9067 1704

200 20
60
15

40
F 100 10
E G 20
5
A B
0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [m³/h]

TM02 8940 1704


0.0 0.2 0.4 0.6 0.8 Q [l/s]

Electrical data 0 10 20 30 40 50 Q [l/min]

Pump type P1 P2 P2 In Capacitor


Voltage [V] Max.
[kW] [kW] [hp] [A] [µF] [Vc]
JPBasic 2 PC 1 x 220-240 0.72 0.44 0.6 3.12 12.5 450
JPBasic 3 PC 1 x 220-240 0.85 0.60 0.8 3.4 12.5 450
JPBasic 4 PC 1 x 220-240 1.13 0.75 1.0 4.7 16 450

Packing dimensions
Dimensions [mm] Vol Weight
Pump type DNA DNM [mm]
[m3] [kg]
A B C E F G Iø H H3 L/A L/B L/H
JPBasic 2 PC 395 212 108 192 14 111 9 375.5 144 Rp 1 Rp 1 524 248 309 0.04 14
JPBasic 3 PC 395 212 108 192 14 111 9 375.5 144 Rp 1 Rp 1 524 248 309 0.04 16
JPBasic 4 PC 414 212 108 197 14 111 9 375.5 144 Rp 1 Rp 1 524 248 309 0.04 16

15
JDBasic General data

JDBasic 2, JDBasic 4 JDBasic 5, JDBasic 7

Gr7899General data

TM00 9974 1097


Motor
Applications
Asynchronous motor, closed and cooled with external
Self-priming centrifugal pump for suction up to 27 ventilation.
metres, reached by means of an ejector to be inserted in
Rotor mounted on greased sealed-for-life ball bearings,
wells with a diameter of 4" or over. For use in supplying
selected to ensure silent running and a long life.
water to farmhouses and in small-scale agriculture.
Built-in thermal and current overload protection and a
Constructional features capacitor permanently in circuit in the single-phase
version.
Pump
For the protection of the three-phase motor it is advis-
Cast iron pump body and motor support treated against able to use a suitable overload protection complying
corrosion also on the inner surface. Technopolymer with the regulations in force.
impeller, diffuser and Venturi tupe and brass nozzle.
Stainless steel pressure disc. Carbon/ceramic mechan- Manufactured according to standard EN 60335-2-41.
ical seal mounted on stainless steel rotor shaft exten- Motor protection: IP 44
sion. Terminal box protection: IP 55
Ejector: Cast iron body with anti-corrosive treatment Insulation class: F
also on the inner surface. Standard voltage: 1 x 220-240 V, 50 Hz
Technopolymer Venturi tube and brass nozzle. 3 x 220-240/380-415 V, 50 Hz.
The ejector is available in 3 models (E20 - E25
- E30) to be chosen according to performance
requirements.
(see tables on pages 17 and 18).

Material specification
Pos. Description Material
1 Pump body Cast iron EN-GJL-200
2 Ejector body Cast iron EN-GJL-200
8
3 Support Cast iron EN-GJL-200 1 6 28 3
4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
(JDBasic 2-4)
Stainless steel AISI 416
7 Shaft with rotor X 12 Cr S 13
(JDBasic 5-7) 2
TM02 8456 0204

AISI 303 X10 Cr NiS 18 9


9
8 Venturi Noryl GFN 2
9 Nozzle Brass 16 4 7
16 Mechanical seal Carbon/Ceramic
28 O-ring gasket NBR

16
JDBasic Technical data

Technical data
Operating range: Up to 4.3 m3/h
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use
Maximum ambient temperature: + 40°C
Maximum operating pressure: JDBasic 2, JDBasic 4: 6 bar (600 kPa)
JDBasic 5, JDBasic 7: 8 bar (800 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.

TM00 9976 1097


JDBasic 2, JDBasic 4
Hydraulic data (n ≈ 2850 min -1)
Delivery pressure in bar
Pump Ejector Suction
1.5 2.0 2.5 3.0 3.5 4.0
Z type type depth
A Capacity table in [l/h]
9 1813 1080 446 33 / /
E25 12 1426 720 225 / / /
JDBasic 2

V
15 900 326 / / / /
H

9 1753 1286 812 524 261 46


H2
H1

E30 12 1345 965 608 356 162 0


15 1166 761 452 228 45 /
X G
B 9 2386 1756 1097 515 126 /
TM02 8455 0204

E25 12 1930 1190 536 87 / /


JDBasic 4

15 1459 773 252 / / /


12 / 1240 872 566 329 156
15 / 1028 701 449 255 96
E30
18 / 785 527 302 150 15
21 / 635 374 180 39 /

Dimensions [mm] Ejector Packing dimensions


Weight

Pump Vol
[kg]

DNA DNM DNE A H H1 L/A L/B L/H [m3]


type A B C E G I H H1 H2 x y z
[mm] [mm] [mm] [mm] [mm] [mm]
JDBasic 2 365 180 90 202 140 9,5 225 47 92 G1¼ G1 G1 97 295 243 G1 G1 G1¼ 452 218 257 0.025 13.9
JDBasic 4 385 180 90 202 140 9,5 225 47 92 G1¼ G1 G1 97 295 243 G1 G1 G1¼ 492 224 277 0.025 16.6

Electrical data Electrical data


Pump P1 P2 P2 In Capacitor Pump P1 P2 P2 In Capacitor
type Voltage [V] Max. type Voltage [V] Max.
[kW] [kW] [hp] [A] [µF] [Vc] [kW] [kW] [hp] [A] [µF] [Vc]
1 x 220-240 0.69 0.44 0.6 3.2 14 450 1 x 220-240 0.79 0.75 1 3.8 16 450
JDBasic 2 3 x 220-240/ JDBasic 4 3 x 220-240/
0.66 0.44 0.6 2.6/1.5 - - 0.64 0.75 1 2.6/1.5 - -
380-415 380-415

17
JDBasic Technical data

JDBasic 5, JDBasic 7
Hydraulic data (n ≈ 2850 min -1)
A B Delivery pressure [bar]
C Pump Ejector Suction
DNM 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0
type type depth
Capaticy table [l/h]
9 3412 2769 2090 1363 586 / / / / / /
V 12 3065 2400 1719 952 143 / / / / / /
E 20
15 2643 2000 1257 495 / / / / / / /
18 2289 1593 826 0 / / / / / / /

JDBasic 5
15 2745 2244 1761 1257 814 435 77 / / / /

E 25 18 2465 1969 1477 997 584 218 / / / / /
21 2206 1712 1224 779 388 45 / / / / /
E G
21 1797 1615 1368 1106 861 658 472 312 163 25 /
E 30 24 1652 1484 1217 962 740 547 378 220 67 / /
27 1520 1333 1069 841 636 448 287 139 / / /
Z A 9 / 3431 2751 2033 1236 448 / / / / /
C
12 / 3043 2324 1554 763 0 / / / / /
E 20
15 / 2665 1936 1145 344 / / / / / /
18 / 2244 1478 675 / / / / / / /
V
JDBasic 7
15 / 2840 2324 1806 1296 849 463 138 / / /
H

18 / 2535 2038 1523 1049 640286 / / / /


E 25
TM02 8457 0204

21 / 2267 1757 1257 817 424 91 / / / /


H1

24 / 1970 1458 989 583 226 / / / / /


21 / 1812 1671 1419 1163 919 716 531 377 226 91
X
E E 30 24 / 1668 1549 1278 1023 791 619 445 297 156 13
27 / 1541 1395 1145 906 700 521 351 206 62 /

Dimensions [mm] Ejector Packing dimensions [mm]

Weight
Vol

[kg]
Pump type DNA DNM DNE A H H1
A B C E G I H H1 H2 x y z L/A L/B L/H [m3]
[mm] [mm] [mm]
JDBasic 5 388 210 50 197 145 11 255 53 108 G1¼ G1 G1 97 295 243 G1 G1 G1¼ 427 246 307 0.032 31
JDBasic 7 462 210 50 197 145 11 255 53 108 G1¼ G1 G1 97 295 243 G1 G1 G1¼ 522 246 307 0.039 35

Electrical data Electrical data


Pump P1 P2 P2 In Capacitor Pump P1 P2 P2 In
type Voltage [V] Max. type Voltage [V] Max.
[kW] [kW] [hp] [A] [µF] [Vc] [kW] [kW] [hp] [A]
JDBasic 5 1 x 220-240 1.56 1.1 1.5 7 31.5 450 JDBasic 5 3 x 220-240/380-415 1.45 1.1 1.5 4.7/2.7
JDBasic 7 1 x 220-240 2.1 1.85 2.5 8.3 40 450 JDBasic 7 3 x 220-240/380-415 1.78 1.85 2.5 5.6/3.2

Instructions for conversion


Conversion from JDBasic 5, JDBasic 7 to JPBasic 5,
JPBasic 7
Screw the nozzle (9) into the seat in the ejector body (2)
and the Venturi tube (8).
Position the O-rings (27) and (29) in their respective
seats and fix the ejector body (2) onto the pump body (1)
with the two screws (53).
TM00 9980 1097 & TM00 9981 1097

Conversion from JPBasic 5, JPBasic 7 to JDBasic 5,


JDBasic 7
Slacken and remove the two joining screws (53)
between the ejector body (2) and the pump body (1).
Collect the O-rings (27) and (29).

18
CHBasic CHBasic

Performance range

p H
[kPa] [m]
600
CHBasic
60 50 Hz

3
55

500
50
4

45
2

400
40

35

300
30

25

200 20

15

100 10

0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 Q [m³/h]

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Q [l/s]
TM02 8933 1804

19
CHBasic General data

CHBasic 2, CHBasic 3, CHBasic 4

6 3

TM02 9065 3204


4 16 28 7
Gr7896

Applications Material specification


Multistage horizontal centrifugal pump, featuring Pos. Description Material
extremely silent running suitable for domestic use for 1 Pump body Cast iron EN-GJL-200
water supply and pressurisation, irrigation of gardens 3 Support Cast iron EN-GJL-200
and vegetable gardens, and moving water in general. 4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2

Constructional features 7 Shaft Stainless steel AISI 303 X10 CrNiS 18 9


16 Mechanical seal Carbon/Ceramic
Pump 28 O-ring gasket NBR

Pump body in cast iron. Motor support in die-cast


aluminium, seal holder in stainless steel.
Mechanical seal in carbon/ceramic. Shaft in stainless
steel. Rotors, diffuser bodies and diffusers in technopol-
ymer. Adjustment rings in stainless steel.
Motor
Continuous service asynchronous motor (2 poles) cooled
by external fan.
Built-in thermal and current overload protection and a
capacitor permanently in circuit in the single-phase
version.
The user is responsible for protection in the three-phase
version.
Motor protection: IP 44
Terminal box protection: IP 55
Insulation class: F
Standard voltage: 1 x 220-240 V, 50 Hz
3 x 220-240/380-415 V, 50 Hz.

20
CHBasic Technical data

Technical data
Operating range: From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive, chemically neutral and
close to the characteristics of water.
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth: 8 metres (800 kPa)
Maximum operating pressure: CHBasic 2, CHBasic 3, CHBasic 4: 6 bar (600 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.

21
CHBasic Technical data

CHBasic 2
0 2 4 6 8 10 12 14 16 18 Q [US GPM]
A
C
DNM 0 2 4 6 8 10 12 14 16 Q [IMP GPM]
P H H
[kPa] [m] [ft]
50 160
45
140
400 40
DNA
H1

H
H2 120
35
300 30 100

TM02 9062 1704


25 80
E F IØ 200 20
G 60
B 15
40
100 10
5 20

0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q [m³/h]

TM02 9009 1304


0.0 0.2 0.4 0.6 0.8 1.0 1.2 Q [l/s]
Electrical data
Pump type P1 P2 P2 In Capacitor
Voltage [V] Max. 0 10 20 30 40 50 60 70Q [l/min]
[kW] [kW] [hp] [A] [µF] [Vc]
1x220-240 0.72 0.45 0.6 3.2 10 450
CHBasic 2
3x220-240/380-415 0.7 0.45 0.6 2.2/1.3 - -

Packing dimensions
Pump Dimensions [mm] Vol Weight
[mm]
type [m3] [kg]
A B C E F G Iø H H1 H2 DNA DNM L/A L/B L/H
CHBasic 2 406 175 122 207 13.5 111 9 200 179 143.5 Rp 1 Rp 1 480 212 265 0.027 12.5

CHBasic 3
0 2 4 6 8 10 12 14 16 18 20 22 24 Q [US GPM]
A
C
DNM P H 0 2 4 6 8 10 12 14 16 18 20 Q [IMP GPM]
[m] H
[kPa] [ft]
55
500 50 160
45
DNA

140
H1

400 40
H2

35 120
300 30 100
TM02 9062 1704

25 80
E F IØ
G 200 20
60
B 15
40
100 10
5 20
0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5Q [m³/h]
TM02 9010 1304

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Q [l/s]


Electrical data
Pump P1 P2 P2 In Capacitor
type Voltage [V] Max. 0 10 20 30 40 50 60 70 80 90 Q [l/min]
[kW] [kW] [hp] [A] [µF] [Vc]
1x220-240 1.2 0.75 1 5.3 20 450
CHBasic 3
3x220-240/380-415 1.2 0.75 1 3.8/2.2 - -

Packing dimensions
Pump Dimensions [mm] Vol Weight
[mm]
type [m3] [kg]
A B C E F G Iø H H1 H2 DNA DNM L/A L/B L/H
CHBasic 3 425 175 122 207 13.5 111 9 213 179 143.5 Rp 1 Rp 1 480 212 265 0.027 15.4

22
CHBasic Technical data

CHBasic 4
0 4 8 12 16 20 24 28 32 Q [US GPM]
A
C
DNM 0 4 8 12 16 20 24 28 Q [IMP GPM]
P H H
[kPa] [m] [ft]
50 160
45
140
400 40
DNA
H1

H
H2 120
35
300 30 100

TM02 9062 1704


25 80
E F IØ 200 20
G 60
B 15
40
100 10
5 20

0 0 0
0 1 2 3 4 5 6 7 Q [m³/h]

TM02 9011 1304


0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]
Electrical data
Pump type P1 P2 P2 In Capacitor
Voltage [V] Max. 0 20 40 60 80 100 120 Q [l/min]
[kW] [kW] [hp] [A] [µF] [Vc]
1x220-240 1.2 0.8 1.1 5.3 20 450
CHBasic 4
3x220-240/380-415 1.2 0.8 1.1 3.8/2.2 - -

Packing dimensions
Dimensions [mm] Vol Weight
Pump type [mm]
[m3] [kg]
A A1 B C E F G H H3 I DNA DNM L/A L/B L/H
CHBasic 4 425 175 122 207 13.5 111 9 213 179 143.5 Rp 1 Rp 1 480 212 265 0.027 15.4

23
CHBasic PT General data

CHBasic PT

6 3

TM02 9065 3204


TM02 9061 1704
4 16 28 7

Applications Material specification


Multistage horizontal centrifugal pump, featuring Pos. Description Material
extremely silent running suitable for domestic use for 1 Pump body Cast iron EN-GJL-200
water supply and pressurisation, irrigation of gardens 3 Support Cast iron EN-GJL-200
and vegetable gardens, and moving water in general. 4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
The set is composed of a diaphragm tank with capacity
7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9
19 litres, pressure switch for automatic operation, pres-
16 Mechanical seal Carbon/Ceramic
sure gauge, JPBasic electric pump complete with power
28 O-ring gasket NBR
cable and plug, kit for coupling the pump and the tank,
all assembled and ready for installation.
Note: Vertical 8 litres or 18 litres tanks are used in some
markets.

Constructional features
Pump
Pump body in cast iron. Motor support in die-cast
aluminium, seal holder in stainless steel.
Mechanical seal in carbon/ceramic. Shaft in stainless
steel. Rotors, diffuser bodies and diffusers in technopol-
ymer. Adjustment rings in stainless steel.
Motor
Continuous service asynchronous motor (2 poles) cooled
by external fan.
Built-in thermal and current overload protection and a
capacitor permanently in circuit.
Motor protection: IP 44
Terminal box protection: IP 55
Insulation class: F
Standard voltage: 1 x 220-240 V, 50 Hz.
Tank
Horizontal type, capacity 19 litres, with butyl
diaphragm, complete with feet on the bottom and
brackets for fixing the pump on top

24
CHBasic PT Technical data

Technical data
Operating range: From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth: 8 metres (800 kPa)
Maximum operating pressure: CHBasic 2 PT, CHBasic 3 PT, CHBasic 4 PT: 6 bar (600 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.

CHBasic 2 PT
A1 D
0 4 8 12 16 20 24 28 32 Q [US GPM]

P H 0 4 8 12 16 20 24 28 Q [IMP GPM]
H
H1

[kPa] [m]
[ft]
55
500 50 160
45
140
400 40
35 120
H

300 30 100
TM02 9066 1704

25 80
200 20
60
15
40
100 10
A B 20
5
CHBasic 2 CHBasic 3 CHBasic 4
0 0 0
0 1 2 3 4 5 6 7 Q [m³/h]

TM02 8939 1704


0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]
Electrical data
Pump type P1 P2 P2 In Capacitor
0 20 40 60 80 100 120 Q [l/min]
Voltage [V] Max.
[kW] [kW] [hp] [A] [µF] [Vc]
CHBasic 2 PT 0.72 0.45 0.60 3.2 12.5 450
CHBasic 3 PT 1 x 220-240 1.2 0.75 1.0 5.3 12.5 450
CHBasic 4 PT 1.2 0.80 1.1 5.3 16 450

Packing dimensions
Dimensions [mm] Vol Weight
Pump type [mm]
[m3] [kg]
A A1 B D H H1 L DNA DNM L/A L/B L/H
CHBasic 2 PT 550 405 270 281 290 200 330 Rp 1 Rp 1 576 366 554 0.107 17.7
CHBasic 3 PT 550 425 270 281 290 200 330 Rp 1 Rp 1 576 366 554 0.107 20.6
CHBasic 4 PT 550 425 270 281 290 200 330 Rp 1 Rp 1 576 366 554 0.107 20.6

25
CHBasic PS General data

CHBasic PS

6 3

TM02 9065 3204


4 16 28 7
Gr7918

Applications Material specification


Multistage horizontal centrifugal pump, featuring Pos. Description Material
extremely silent running suitable for domestic use for 1 Pump body Cast iron EN-GJL-200
water supply and pressurisation, irrigation of gardens 3 Support Cast iron EN-GJL-200
and vegetable gardens, and moving water in general. 4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2

Constructional features 7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9


16 Mechanical seal Carbon/Ceramic
Pump 28 O-ring gasket NBR

Pump body in cast iron. Motor support in die-cast


aluminium, seal holder in stainless steel.
Mechanical seal in carbon/ceramic. Shaft in stainless
steel. Rotors, diffuser bodies and diffusers in technopol-
ymer. Adjustment rings in stainless steel.
Motor
Continuous service asynchronous motor (2 poles) cooled
by external fan.
Built-in thermal and current overload protection and a
capacitor permanently in circuit.
Motor protection: IP 44
Terminal box protection: IP 55
Insulation class: F
Standard voltage: 1 x 220-240 V, 50 Hz.

26
CHBasic PS Technical data

Technical data
Operating range: From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth: 8 metres (800 kPa)
Maximum operating pressure: CHBasic 2 PS, CHBasic 3 PS, CHBasic 4 PS: 6 bar (600 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.

CHBasic PS
0 4 8 12 16 20 24 28 32 Q [US GPM]
A
C D
DNM
H 0 4 8 12 16 20 24 28 Q [IMP GPM]
DNM

P
[kPa] [m] H
[ft]
55
500 50 160
45
140
400
H
H1

40
DNA

H2

120
H3

35
300 30 100
TM02 9064 1704

25 80
E Iø 200
F G 20
60
B 15
40
100 10
5 20
CHBasic 2 CHBasic 3 CHBasic 4
0 0 0
0 1 2 3 4 5 6 7 Q [m³/h]

TM02 8939 1704


Electrical data 0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]

Pump type P1 P2 P2 In Capacitor


Voltage [V] Max. 0 20 40 60 80 100 120 Q [l/min]
[kW] [kW] [hp] [A] [µF] [Vc]
CHBasic 2 PS 1.75 0.45 0.60 3.2 10 450
CHBasic 3 PS 1 x 220-240 1.20 0.75 1.00 5.3 20 450
CHBasic 4 PS 1.20 0.80 1.10 5.3 20 450

Packing dimensions
Dimensions [mm] Vol Weight
Pump type [mm]
[m3] [kg]
A B C D E F G H H1 H2 H3 I DNA DNM L/A L/B L/H
CHBasic 2 PS 405 281 122 196 205 14 111 238 205 200 144 9 Rp 1 Rp 1 449 309 244 0.03 14
CHBasic 3 PS 425 281 122 196 205 14 111 238 205 200 144 9 Rp 1 Rp 1 449 309 244 0.031 17
CHBasic 4 PS 425 281 122 196 205 14 111 238 205 200 144 9 Rp 1 Rp 1 449 309 244 0.03 17

27
CHBasic PC General data

CHBasic PC the membrane which gradually releases a spring. The


sensors detect the movement, send a signal to the
electronic unit which enables pump start-up.
3. Automatically stops the pump when the users stop
drawing water. When the appliances are closed, un-
der the effect of the rise in pressure within the hy-
draulic system, the membrane totally compresses the
spring. This new situation is analysed by the sensors
which send the unit a signal to stop the pump. The
stop is timed in order to prevent the pump from be-
ing subjected to repeated starts caused by users
opening and closing the appliances within a few sec-
onds of each other. Furthermore, if boilers are sup-
plied, the continuous delivery of hot water is
guaranteed by timing the stops.
4. Instant pump start when one of the appliances is
Gr7916

opened even with a minimum amount of water


drawn.
5. In the event of leaks in the system (drips or small
Applications trickles) the device limits the number of cycles, pro-
longing pump running time by about 10 seconds.
Multistage horizontal centrifugal pump, featuring
extremely silent running suitable for domestic use for 6. It eliminates water hammering by means of a spe-
water supply and pressurisation, irrigation of gardens cific shock absorber which absorbs the effect.
and vegetable gardens, and moving water in general. 7. Manual reset in the event of a breakdown in the hy-
draulic circuit or of overload protector intervention;
Operation in this case, after eliminating the cause, press the
"RESET" button positioned on the terminal board
The pump is equipped with a Presscontrol (PC) which cover for a few seconds until the "ALARM" LED
controls, manages and commands it, regulating its oper- switches off.
ation, limiting the number of starts and guaranteeing
8. In the event of a power cut, automatic reset as soon
maximum pressure stability inside the hydraulic circuit
as the power is restored.
in which it is installed.
9. The system is self-protected against overheating.
The automatic devices is the result of a series of studies When there is an excess in temperature inside the
conducted to optimise the efficiency of the system while motor windings, this operation is carried out auto-
preserving the structural features and sturdiness of matically. It is also restored automatically once the
existent devices. temperature has dropped below the level which
Automatic sets differ from the traditional systems guarantees operation without damage to the system.
equipped with a pressure switch based on pump starting
and stopping as they avoid sudden variations and drops Constructional features
in pressure. They are basically equipped with a double
control device, as built-in electrical circuit gathers the Pump
data regarding pressure and water flow in the system Pump body in cast iron. Motor support in die-cast
and processes them to allow the pump to operate under aluminium, seal holder in AISI 304 steel.
optimum performance conditions.
Mechanical seal in carbon/ceramic. Rotor shaft in AISI
The automatic device is supplied pre-installed on the 304 steel. Rotors, diffuser bodies and diffusers in tech-
pump, requires no type of regulation and considerably nopolymer. Adjustment rings in stainless steel.
reduces overall dimensions by totally eliminating the
bulky tanks used traditional installations. Motor
Continuous service asynchronous motor (2 poles) cooled
Optimised management of the hydraulic by external fan.
installation and its components
Built-in thermal and current overload protection and a
1. Enables the system to operate only when there is wa-
capacitor permanently in circuit.
ter present; if, for any reason, no water reaches the
system, it blocks the pump, so that it does not oper- Motor protection: IP 44
ate while dry. In this case the ALARM LED lights up. Terminal box protection: IP 55
2. Maintains pump operation when the appliances are Insulation class: F
opened by one or more users, in order to prevent sud- Standard voltage: 1 x 220-240 V, 50 Hz.
den changes in pressure. When an appliance is
opened the depression created in the system acts on

28
CHBasic PC Technical data

6 3

4 16 28 7 TM02 9065 3204

Material specification
Pos. Description Material
1 Pump body Cast iron EN-GJL-200
3 Support Cast iron EN-GJL-200
4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9
16 Mechanical seal Carbon/Ceramic
28 O-ring gasket NBR

29
CHBasic PC Technical data

Technical data
Operating range: From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth: 8 metres (800 kPa)
Maximum operating pressure: CHBasic 2 PC, CHBasic 3 PC, CHBasic 4 PC: 6 bar (600 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.

CHBasic PC
C
DMN
0 4 8 12 16 20 24 28 32 Q [US GPM]

P H 0 4 8 12 16 20 24 28 Q [IMP GPM]
[kPa] [m] H
[ft]
55
500 50
DNA

160
H

45
140
400 40
35 120
300 30 100
TM02 9063 1704

25 80
200 20
60
F Iø 15
40
E G 100 10
B 5 20
A CHBasic 2 CHBasic 3 CHBasic 4
0 0 0
0 1 2 3 4 5 6 7 Q [m³/h]

TM02 8939 1704


0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]
Electrical data
Pump type P1 P2 P2 In Capacitor
Voltage [V] 0 20 40 60 80 100 120 Q [l/min]
Max.
[kW] [kW] [hp] [A] [µF] [Vc]
CHBasic 2 PC 0.72 0.45 0.6 3.2 10 450
CHBasic 3 PC 1 x 220-240 1.2 0.75 1.0 5.3 20 450
CHBasic 4 PC 1.2 0.80 1.1 5.3 20 450

Packing dimensions
Dimensions [mm] Vol Weight
Pump type [mm]
[m3] [kg]
A B C E F G H Iø DNA DNM L/A L/B L/H
CHBasic 2 PC 406 212 122 207 13.5 111 376 9 Rp 1 Rp 1 524 248 309 0.04 14
CHBasic 3 PC 425 212 122 207 13.5 111 376 9 Rp 1 Rp 1 524 248 309 0.04 16
CHBasic 4 PC 425 212 122 207 13.5 111 376 9 Rp 1 Rp 1 524 248 309 0.04 16

30
NSBasic NSBasic
Single impeller

Performance range

p H
[kPa] [m]
700 NSBasic
70
50 Hz

65
5-60
600
60

55

500 5-50
50

45 6-40
3-40
400
40
6-30
35
5-33
300 30

25
4-23
200 20 13-18

15

100 10

0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [m³/h]
TM02 8934 1804

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]

31
NSBasic General data

NSBasic single impeller pumps


1 4 28 3

TM02 9070 1704


16
Gr7897
7

Applications Material specification


Single impeller centrifugal pump designed for lifting Description Material Pump types
water in domestic, civil, industrial and agricultural 1 Pump body Cast iron EN-GJL-200
installations and for decanting, mixing and irrigating 3 Support Cast iron EN-GJL-200
uses. 4 Impeller Noryl GFN 2
X 12 CrNi 1810 NSBasic 4-23 - NSBasic 13-18
7 Shaft
Constructional features X 10 CrNi 1809 NSBasic 5-33
16 Mechanical seal Carbon/Ceramic
Pump 28 O-Ring Gasket NBR

Cast iron pump body and motor support treated against


corrosion also on the inner surface.
Technopolymer and cast iron impeller.
Carbon/ceramic mechanical seal mounted on stainless
steel rotor shaft extension.
Motor
Induction motor, closed and cooled with external fan.
Rotor mounted on oversized greased sealed-for-life ball
bearing to ensure silent running and long life. Built-in
thermal and current overload protection and a capacitor
permanently in circuit in the single-phase version. The
user is responsible for the protection in the three-phase
version.
Manufactured according to standard EN 60335-2-41.
Motor protection: IP 44
Terminal box protection: IP 55 for the single-phase
version
Insulation class: F
Standard voltage: 1x220-240 V, 50 Hz
3x220-240/380-415 V, 50 Hz.

32
NSBasic Technical data

Technical data
Operating range: From 1.8 to 16.8 m3/h with head up to 34 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non viscous, non aggressive,
noncrystallized, chemically neutral, close to the characteristics of water.
Liquid temperature range: NSBasic 4-23, NSBasic 5-33, NSBasic 13-18: from -10°C to + 50°C
Maximum ambient temperature: +40°C
Maximum operating pressure: NSBasic 4-23, NSBasic 5-33, NSBasic 13-18: 6 bar (600 kPa)
Installation: Fixed in a horizontal or vertical position, as long
as the motor is above the pump
Special versions on request: Other voltages and/or frequencies.
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.

NSBasic 4-23

0 4 8 12 16 20 24 Q [US GPM]

0 4 8 12 16 20 Q [IMP GPM]
P H H
[kPa] [m] [ft]
20
60
160
TM02 9089 1804Single impeller

15
40
10
80
5 20

0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]
P2 P2 Eta
[hp] [kW] [%]
0.4 P2 40
0.4
0.2 20
0.2
Eta
0.0 0.0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [l/s]

TM02 9012 1304


Electrical data
Pump P1 P2 Capacitor 0 10 20 30 40 50 60 70 80 90 Q [l/min]
P2 In
type Voltage [V] Max.
[kW] [kW] [hp] [A] [µF] [Vc]

NSBasic 4-23 1x220-240 0.65 0.37 0.5 3.0 10 450


NSBasic 4-23 3x220-240/380-415 0.64 0.37 0.5 2.3/1.3 - -

Pump Dimensions [mm] Packing dimensions [mm] Vol Weight


DNA DNM
type A B C D E F G I H H1 H2 L/A L/B L/H [m3] [kg]
NSBasic 4-23 275 160 50 100 50 15 110 9 205 85 120 Rp 1 Rp 1 362 222 262 0.021 10.3

33
NSBasic Technical data

NSBasic 5-33

0 4 8 12 16 20 24 28 32 36 Q [US GPM]

0 4 8 12 16 20 24 28 32 Q [IMP GPM]
P H H
[kPa] [m] [ft]
320
30 100
240 80
20 60
160
40
80 10
20
0 0 0

TM02 9089 1804


0 1 2 3 4 5 6 7 8 Q [m³/h]
P2 P2 Eta
[hp] [kW] [%]
0.8 40
P2
0.8
0.4 20
0.4
Eta
0.0 0.0 0
0 1 2 3 4 5 6 7 8 Q [m³/h]
0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [l/s]
Electrical data

TM02 9013 1304


Pump P1 P2 P2 In Capacitor 0 20 40 60 80 100 120 Q [l/min]
type Voltage
[V] Max.
[kW] [kW] [hp] [A] [µF] [Vc]

NSBasic 5-33 1x220-240 1.3 0.75 1 6.0 20 450


NSBasic 5-33 3x220-240/380-415 1.2 0.75 1 4.3/2.5 - -

Packing dimensions
Pump Dimensions [mm] Vol Weight
DNA DNM [mm]
type [m3] [kg]
A B C D E F G I H H1 H2 L/A L/B L/H
NSBasic 5-33 300 185 50 108 58 15 140 9 235 100 135 Rp 1 Rp 1 392 232 262 0.024 14.7

NSBasic 13-18

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Q [US GPM]

0 5 10 15 20 25 30 35 40 45 50 55 60 Q [IMP GPM]
P H H
[kPa] [m] [ft]
20
60
160
15
40
10
80
5 20

0 0 0
TM02 9089 1804

0 2 4 6 8 10 12 14 16 Q [m³/h]
P2 P2 Eta
[hp] [kW] [%]
0.8 40
0.8 P2

0.4 0.4 20
Eta
0.0 0.0 0
0 2 4 6 8 10 12 14 16 Q [m³/h]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]
TM02 9014 1304

Electrical data
0 40 80 120 160 200 240 Q [l/min]
Pump P1 P2 P2 In Capacitor
type Voltage
[V] Max.
[kW] [kW] [hp] [A] [µF] [Vc]

NSBasic 13-18 1x220-240 1.1 0.75 1 4.6 20 450


NSBasic 13-18 3x220-240/380-415 1.1 0.75 1 3.6/2.1 - -

Packing dimensions
Pump Dimensions [mm] Vol Weight
DNA DNM [mm]
type [m 3] [kg]
A B C D E F G I H H1 H2 L/A L/B L/H
NSBasic 13-18 312 169 45 114 69 15 110 9 210 210 125 Rp 1½ Rp 1½ 392 232 262 0.024 14

34
NSBasic General data

NSBasic twin impeller pumps


34 3

TM02 9069 1704


Gr7928

1 4 28 16 7

Applications Material specification


Muliti-stage centrifugal pump with opposed twin Description Material Pump types

impellers. Cast iron


1 Pump body
EN-GJL-200
Designed for use in pressurisation units for water
Cast iron
supply systems and for supplying pressurised tanks. 3 Support
EN-GJL-200
Suitable also for sprinkling, irrigation and other water NSBasic 3-40 - NSBasic 5-50 -
Noryl GFN 2
supply application. 4 Impeller NSBasic 6-30 - NSBasic 6-40
Ultem 2300 NSBasic 5-60

Constructional features 7 Shaft


Stainless steel
ANSI X12
CrNi 1810
Pump
16 Mechanical seal Carbon/Ceramic
Cast iron pump body and motor support treated against Impregnated
28 O-ring gasket
corrosion also on the inner surface. Cellulose
Technopolymer and cast iron impeller. Carbon/ceramic Cast iron
34 Intermediate Disc
EN-GJL-200
mechanical seal mounted on stainless steel rotor shaft
extension.
Motor
Induction motor, closed and cooled with external fan.
Rotor mounted on oversized greased sealed-for-life ball
bearing to ensure silent running and long life. Built-in
thermal and current overload protection and a capacitor
permanently in circuit in the single-phase version. The
user is responsible for the protection in the three-phase
version.
Manufactured according to standard EN 60335-2-41.
Motor protection: IP 44
Terminal box protection: IP 55 for the single-phase
version up to
and including 0.75 kW
Insulation class: F
Standard voltage: 1x220-240 V, 50 Hz
3x220-240/380-415 V, 50 Hz.

35
NSBasic Technical data

Technical data
Operating range: From 1.5 to 10.8 m3/h with head up to 60 metres.
Liquid quality requirements: clean, free from solids or abrasive substances, non viscous, non aggressive, non
crystallized, chemically neutral, close to the characteristics of water.
Liquid temperature range: NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: from –10°C to + 50°C
NSBasic 5-60: from –15°C to + 110°C
Maximum ambient temperature: +40°C
Maximum operating pressure: NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: 6 bar ( 600 kPa)
NSBasic 5-50, NSBasic 5-60: 8 bar ( 800 kPa)
Installation: Fixed in a horizontal or vertical position, as long as the motor is above the
pump.
Special versions on request: Other voltages and/or frequencies.
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.

NSBasic 3-40

0 4 8 12 16 20 24 Q [US GPM]

0 4 8 12 16 20 Q [IMP GPM]
P H H
[kPa] [m] [ft]
400 40
120
300 30
TM02 9088 1804Twin impeller

80
200 20

100 10 40

0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]
P2 P2 Eta
[hp] [kW] [%]
0.8 40
0.8 P2

0.4 0.4 20
Eta
0.0 0.0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [l/s]
Electrical data

TM02 9015 1304


Pump P1 P2 P2 In Capacitor 0 10 20 30 40 50 60 70 80 90 Q [l/min]
type Voltage [V] Max.
[kW] [kW] [hp] [A] [µF] [Vc]

NSBasic 3-40 1x220-240 1.2 0.75 1 5.5 20 450


NSBasic 3-40 3x220-240/380-415 1.2 0.75 1 3.8/2.2 - -

Packing dimensions
Pump Dimensions [mm] Vol Weight
DNA DNM [mm]
type [m3] [kg]
A B C D E F G I H H1 H2 L/A L/B L/H
NSBasic 3-40 342 180 76 148 72 15 148 9.5 235 100 135 Rp 1 Rp 1 392 232 262 0.024 16.1

36
NSBasic Technical data

NSBasic 5-50

0 4 8 12 16 20 24 28 32 Q [US GPM]

0 4 8 12 16 20 24 28 Q [IMP GPM]
P H H
[kPa] [m] [ft]
50 160
400 40
120
300 30
80
200 20
100 10 40

0 0 0

TM002 9088 1804


0 1 2 3 4 5 6 7 Q [m³/h]
P2 P2 Eta
[hp] [kW] [%]
1.6 40
1.6 P2
0.8 20
0.8
Eta
0.0 0.0 0
0 1 2 3 4 5 6 7 Q [m³/h]
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 Q [l/s]
Electrical data

TM02 9016 1304


Pump P1 P2 P2 In Capacitor 0 10 20 30 40 50 60 70 80 90 100 110 120 Q [l/min]
type Voltage [V] Max.
[kW] [kW] [hp] [A] [µF] [Vc]

NSBasic 5-50 1x220-240 1.9 1.1 1.5 8.3 31.5 450


NSBasic 5-50 3x220-240/380-415 2.0 1.1 1.5 6.0/3.5 - -

Packing dimensions
Pump Dimensions [mm] Vol Weight
Phase DNA DNM [mm]
type [m3] [kg]
A B C D E F G I H H1 H2 L/A L/B L/H
NSBasic 5-50 1 370 210 75 144 69 15 165 11.5 268 118 150 Rp 1¼ Rp 1 415 235 295 0.029 23.3
NSBasic 5-50 3 370 210 75 144 69 15 165 11.5 268 118 150 Rp 1¼ Rp 1 415 234 295 0.029 23.8

NSBasic 5-60

0 4 8 12 16 20 24 28 32 36 40 Q [US GPM]

0 4 8 12 16 20 24 28 32 Q [IMP GPM]
P H H
[kPa] [m] [ft]
600 60 200
160
400 40 120
80
200 20
40
0 0 0
TM02 9088 1804

0 1 2 3 4 5 6 7 8 9 Q [m³/h]
P2 P2 Eta
[hp] [kW] [%]
2 40
2 P2
1 1 20
Eta
0 0 0
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [l/s]
TM02 9017 1304

Electrical data
Pump P1 P2 P2 In Capacitor 0 20 40 60 80 100 120 140 Q [l/min]
type Voltage [V] Max.
[kW] [kW] [hp] [A] [µF] [Vc]

NSBasic 5-60 1x220-240 2.7 1.8 2.5 12.8 40 450


NSBasic 5-60 3x220-240/380-415 2.5 1.8 2.5 8.4/4.8 - -

Packing dimensions
Pump Dimensions [mm] Vol Weight
DNA DNM [mm]
type [m3] [kg]
A B C D E F G I H H1 H2 L/A L/B L/H
NSBasic 5-60 370 210 75 144 69 15 165 11.5 268 118 150 Rp 1¼ Rp 1 415 234 295 0.032 23.8

37
NSBasic Technical data

NSBasic 6-30

0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]

0 4 8 12 16 20 24 28 32 36 40 Q [IMP GPM]
P H H
[kPa] [m] [ft]
400 40
120
300 30
80
200 20

100 10 40

0 0 0

TM02 9090 1804


0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
P2 P2 Eta
[hp] [kW] [%]
1.6 40
1.6 P2
0.8 20
0.8 Eta
0.0 0.0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [l/s]
Electrical data

TM02 9018 1304


Pump P1 P2 P2 In Capacitor 0 20 40 60 80 100 120 140 160 180Q [l/min]
type Voltage
[V] Max.
[kW] [kW] [hp] [A] [µF] [Vc]

1x220-240V 1.56 1.1 1.5 7.1 25 450


NSBasic 6-30
3x220-240/380-415 1.56 1.1 1.5 5.4/3.1 - -

Packing dimensions
Pump Dimensions [mm] Vol Weight
DNA DNM [mm]
type [m3] [kg]
A B C E F G I H H1 L/A L/B L/H
NSBasic 6-30 387 205 88 179 20 145 11 233 108 Rp 1½ Rp 1 415 234 295 0.028 21.5

NSBasic 6-40

0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]

0 4 8 12 16 20 24 28 32 36 40 Q [IMP GPM]
P H H
[kPa] [m] [ft]
400 40
120
300 30
80
200 20
100 10 40

0 0 0
TM02 9090 1804

0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
P2 P2 Eta
[hp] [kW] [%]
1.6 P2 40
1.6
0.8 20
0.8 Eta
0.0 0.0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [l/s]
Electrical data
TM02 9019 1304

Pump P1 P2 P2 In Capacitor 0 20 40 60 80 100 120 140 160 180Q [l/min]


type Voltage
[V] Max.
[kW] [kW] [hp] [A] [µF] [Vc]

1x220-240V 2 1.85 2.5 9 40 450


NSBasic 6-40 3x220-240/
2.0 1.85 2.5 6.2/3.6 - -
380-415

Packing dimensions
Dimensions [mm] Vol Weight
Pump type DNA DNM [mm]
[m3] [kg]
A B C E F G I H H1 L/A L/B L/H
461 205 88 179 20 145 11 233 108 Rp 1½ Rp 1 510 234 285 0.034 25.9
NSBasic 6-40
387 205 88 179 20 145 11 233 108 Rp 1½ Rp 1 415 234 295 0.028 22

38
KPBasic KPBasic

Performance range

p H
[kPa] [m]
10.5 KPBasic
100 50 Hz
10.0 600 (A)

9.5
90
9.0

8.5
80
8.0

7.5
70
7.0
300 A
6.5
60
6.0

5.5 200

50 5.0

4.5
40 4.0

3.5
30 3.0

2.5

20 2.0

1.5

10 1.0

0.5

0 0.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [m³/h]
TM02 8937 1804

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]

39
KPBasic General data

KPBasic KPBasic 200: Supplied standard with 10 metres


of H05 RN-F power cable.
KPBasic 300 A: Supplied standard with 10 metres
of H05 RN-F power cable.
Note: 5 m cable om request.
KPBasic 600: Supplied standard with 10 metres
of H07 RN-F power cable.
KPBasic 600 A: Supplied standard with 10 metres
of H07 RN-F power cable.
Note: 5m cable on request.
Degree of protection: IP 68
Insulation class: F
Manufactured according to standard EN 60335-2-41.
Gr7913 Standard voltage: 1 x 220-240V, 50 Hz
3 x 380-415V, 50 Hz.

Applications
The submersible pump from the KPBasic series is
designed mainly for automatically operated fixed appli-
cations in domestic use, draining basements and
Descriptions and materials
garages which are subject to flooding.
Thanks to its compact, easy to handle design, it can also
be used as a portable pump for emergencies such as
lifting water from tanks or rivers, emptying swimming
pools, fountains, excavations and underpasses.
It is also ideal for gardening and hobbies in general.
The level switch allows fixed installation and guarantees
automatic pump operation.
Table of performance ranges and
KPBasic
possible applications
DNM connections Rp 1¼
Flow rate Q [m3/h] Max. 16
Head H [m] Max. 10.8
o
Temperature t [ C] Max. +40 29
Rain water z
1 54
Clean waste water z
TM02 8468 3204

73
78
Constructional features
Pump 79 32 4
Water-resistant technopolymer pump body, impeller,
top body and suction grid. Stainless steel motor casing,
Pos. Descriptions Materials
rotor shaft and screws.
1 Pump body Noryl GFN 2
Triple "O" ring seals interposed with oil chamber.
4 impeller Noryl GFN 2
Motor 29 O-ring gasket NBR

Continous duty submersible induction motor. 32 Stop ring Stainless steel 12E

Stator fitted in an airtight stainless steel casing covered Motor

by a top body which encases cabling, microswitch and Stainless steel AISI 304
- Top body
54 X5 CrNi 1810
capacitor. Rotor mounted on oversized greased sealed-
Stainless steel AISI 304
for-life ball bearings selected to guarantee silent - Shaft
X5 CrNi 1810
running and long life. Built-in thermal and current over- 78 Pressure disc Noryl GFN 2
load protection and a capacitor which is permanently in 79 Suction grid Noryl GFN 2
circuit in the single-phase version.

40
KPBasic Technical data

Technical data
Operation range: From 1 to 16 m3/h with head up to 10.2 metres
Liquid quality requirements: Grey water without fibres
Granulometric passage though the suction grid: KPBasic 200 5 mm
KPBasic 300A 10 mm
KPBasic 600 10 mm
KPBasic 600A 10 mm
Minimum draught depth: KPBasic 200 8 mm
KPBasic 300A 85 mm
KPBasic 600 38 mm
KPBasic 600A 175 mm
Liquid temperature range: From 0°C to +35°C
Maximum immersion: 7 metres
Maximum dry running time: 1 minute
Automatic float switch: Type name extension: A
Special versionson request: Other voltages and/or frequencies
Installation: Fixed or portable in a vertical position.
The minimum pit dimensions for fixed installation with automatic
operation are indicated in the drawing.

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.

KPBasic 300 A KPBasic 600 A


Minimum dimension for the pit for KPBasic 300 A with Minimum dimension for the pit for KPBasic 600 A with
automatic float switch automatic float switch
400

500
TM02 9100 1804

TM02 9101 1804

400 400

41
KPBasic Technical data

KPBasic 200 KPBasic 300A


0 4 8 12 16 20 24 28 32 36 40 44 Q [US GPM] 0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 Q [US GPM]

0 4 8 12 16 20 24 28 32 36 Q [IMP GPM] 0 4 8 12 16 20 24 28 32 36 40 44 48 Q [IMP GPM]


P H H P H H
[kPa] [m] [ft] [kPa] [m] [ft]
80 8 80 8
25 25
60 6 20 60 6 20
15 15
40 4 40 4
10 10
20 2 20 2
5 5
0 0 0 0 0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h] 0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
P2 P2 Eta P2 P2 Eta
[hp] [kW] [%] [hp] [kW] [%]
0.2 40 0.2 40
0.2 0.2 P2
P2
0.1 20 0.1 0.1 20
0.1

TM02 9020 1304


Eta

TM02 9021 1304


Eta
0.0 0.0 0 0.0 0.0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h] 0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [l/s] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 Q [l/s]

0 20 40 60 80 100 120 140 160 Q [l/min] 0 20 40 60 80 100 120 140 160 180 200 Q [l/min]

KPBasic 200, KPBasic 300A


Liv.max.
H1
H

Liv.min.
H2

TM02 8466 0204

E
B
A
D

Electrical data
Pump P1 P2 P2 In Capacitor
type Voltage [V] Max.
[W] [kW] [hp] [A] [µF] [Vc]

KPBasic 200 1x220-240 350 0.22 0.3 1.5 8 450


KPBasic 300A 1x220-240 350 0.22 0.3 1.5 8 450

Pump Dimensions [mm] Liv. min. Liv. max. Packing dimensions [mm] Vol Weight
DNM
type A B D E H H1 H2 [mm] [mm] L/A L/B L/H [m3] [kg]
KPBasic 200 185 140 225 82 266 390 38,5 100 350 Rp 1¼ 207 227 312 0.016 4.5
KPBasic 300A 185 140 225 82 275 390 47,5 100 350 Rp 1¼ 207 227 312 0.016 4.6

42
KPBasic Technical data

KPBasic 600 (A) KPBasic 600 (A)


0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Q [US GPM]

0 5 10 15 20 25 30 35 40 45 50 55 60 Q [IMP GPM]
P H H
[kPa] [m] [ft]
10
30
80 8 25

Liv.max.
60 6 20

H1
H

Liv.min.
40 4 15
10
20 2

H2
5
0 0 0

P2 P2 0 2 4 6 8 10 12 14 16 Q [m³/h] Eta
[hp] [kW] [%]
0.8 0.6 P2 30
0.6 0.4 20
0.4 E
0.2 Eta 10

TM02 8466 0204


0.2

TM02 9022 1304


0.0 0.0 0
B
0 2 4 6 8 10 12 14 16 Q [m³/h]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s] A
D
0 40 80 120 160 200 240 Q [l/min]

Electrical data
Pump P1 P2 P2 In Capacitor
type Voltage [V] Max.
[W] [kW] [hp] [A] [µF] [Vc]

KPBasic 600 1x220-240 800 0.55 0.75 3.4 14 450


KPBasic 600A 1x220-240 800 0.55 0.75 3.4 14 450
KPBasic 600 3x380-415 800 0.55 0.75 3.4 - -

Pump Dimensions [mm] Liv. min. Liv. max. Packing dimensions [mm] Vol Weight
DNM
type A B D E H H1 H2 [mm] [mm] L/A L/B L/H [m3] [kg]
KPBasic 600 200 160 225 90 376 490 73 200 450 Rp 1 ¼ 207 227 422 0.021 7
KPBasic 600A 200 160 225 90 376 490 73 200 450 Rp 1 ¼ 207 227 422 0.021 6.7

43
PFBasic PFBasic

Performance range

p H
[kPa] [m]
600
PF(P)Basic
60 50 Hz

55 PFPBasic 2-50

500
50
PFBasic 2-50

45

400
40

35 PFBasic 1-30

300 30

25

200 20

15

100 10

0 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Q [m³/h]
TM02 8935 1804

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Q [l/s]

44
PFBasic General data

PFBasic

1
28
4

TM02 9071 1704


GR7901 16 7

Applications Material specification


Peripheral centrifugal pump with compact dimensions. Pos. Description Material
Able to generate high heads and suitable for domestic 1 Pump body Cast iron EN-GJL-200
installations, water supply systems, light gardening 4 Impeller Brass PCu Zn 40 Pb2 5705-65
applications, draining and filling cisterns, as well as light 7 Shaft
Stainless steel AISI 416
X12 CrS 13
industrial uses such as feeding pressurized boilers (anti-
16 Mechanical seal Carbon/ceramic
condensation).
28 O-ring gasket NBR rubber

Constructional features
Pump
Cast iron pump body and motor support with brass wear
disc.
Brass impeller. Carbon/ceramic mechanical seal.
Motor
Induction motor, closed and cooled with external venti-
lation. Rotor mounted on oversized greased sealed-for-
life ball bearings to ensure silent running and long life.
The motor incorporates a built-in thermal and current
overload protection as well as a capacitor, switched on
permanently.
Manufactured according to standard EN 60335-2-41.
Motor protection: IP 44
Terminal box protection: IP 55
Insulation class: F
Standard voltage: Single-phase 220-240 V,
50 Hz.
Other voltages and frequencies are available on request.

45
PFBasic Technical data

Technical data
Operating range: From 0.3 to 2.7 m3/h with heads up to 53 metres.
Pumped liquid: Cclean, free from solids or abrasive substances, non viscous, non aggressive, non crys-
tallized, chemically neutral, close to the characteristics of water.
Liquid temperature range: from 0°C to +35°C for domestic use (EN 60335-2-41)
From –10°C to +50°C for other uses.
Maximum ambient temperature: +40°C
Maximum operating pressure: - PFBasic 1-30: 6 bar (600 kPa)
- PFBasic 2-50: 10 bar (1000 kPa)
Installation: Fixed in the horizontal position.
The performance curves are based on a kinematic viscosity value of 1 mm²/s and a density equal to 1000 kg/m3.
Curve tolerances according to ISO 9906, annex A.

p H
[kPa] [m]
56 PFBasic
52 2-50
50 Hz
480 48 ISO 9906 Annex A

44
400 40
36
320 32 1-30

28
240 24
20
160 16
12
80 8
4
0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [m³/h]
TM02 9091 1804

TM02 6757 1304


0.0 0.2 0.4 0.6 Q [l/s]

Electrical data
P1 max. P2 P2 In Capacitor
Model Voltage [V]
[kW] [kW] [hp] [A] [µF] [Vc]
PFBasic 1-30 1 x 220-240 0.47 0.3 0.4 2 8 450
PFBasic 2-50 1 x 220-240 0.86 0.6 0.8 3.8 12.5 450

Dimensions and weights


Packing dimensions [mm] Volume Weight
Model A B B1 C E F G I H H1 H2 DNA DNM
L/A L/B L/H [m 3] [kg]
PFBasic 1-30 228 132 165 22 46 - 65 8 158 103 138 Rp 1 Rp 1 259 164 197 0.008 5.3
PFBasic 2-50 255 130 - 26 106 80 100 7 186 108 153 Rp 1 Rp 1 271 176 209 0.01 7.5

46
PFPBasic General data

PFPBasic 2-50
1 3 28 7

Gr7900General data

TM02 9072 1704


4 16

Applications Materials
Self-priming pump with side liquid channel and star- Pos. Description Material
shaped impeller, with excellent suction capacities even Cast iron EN-GJL-200,
1 Pump body with brass wear ring
in unfavourable operating conditions such as the pres- PCuZn 40 Pb2 5705/65
ence of air bubbles or lack of continuity in the sucked 3 Motor support Brass PCu Zn 40 Pb2 5705/65
liquid. Used in domestic, agricultural civil and industrial 4 Impeller Brass PCu Zn 40 Pb2 5705/65
installations. Stainless steel AISI 416
7 Shaft
X12 CrS 13
Constructional features 16 Mechanical seal Carbon/ceramic
28 O-ring gasket FKM
Pump
Cast iron pump body with brass pressure disc.
Motor support and impeller completely made of brass,
to avoid the risk of blockage.
Carbon/ceramic mechanical seal.
Stainless steel motor shaft.
Motor
Asynchronous motor, cooled by external fan. Rotor
mounted on oversized, greased and sealed-for-life ball
bearings to ensure quiet operation and long life.
The single-phase version has built-in thermal and
current overload protection.
Manufactured according to standard EN60335-2-41.
Motor protection: IP 44
IP 55 terminal board protection
Insulation class: F
Standard voltage: Single-phase 220-240 V, 50 Hz.
Other voltages and frequencies are
available on request.

47
PFPBasic Technical data

Operating conditions
Operating range: From 0.5 to 2.7 m3/h with heads up to 53 metres.
Pumped liquid: Clean, free from solids or abrasive substances, non-aggressive, noncrystallized,
chemically neutral, similar to the characteristics of water.
Liquid temperature range: From –10°C to +80°C
Maximum ambient temperature: +40°C
Maximum operating pressure: 10 bar (1000 kPa)
Installation: Fixed in the horizontal position.
The performance curves are based on a kinematic viscosity value of 1 mm²/s and a density equal to 1000 kg/m3.
Curve tolerances according to ISO 9906, annex A.

p H
[kPa] [m]
56 PFPBasic 2-50
52 50 Hz
480 48 ISO 9906 Annex A

44
400 40
36
320 32
28
240 24
20
160 16
12
80 8
4
0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [m³/h]
TM02 9092 1804

TM02 6758 1304


0.0 0.2 0.4 0.6 0.8 Q [l/s]

Electrical data
P1 max. P2 P2 In Capacitor
Model Voltage [V]
[kW] [kW] [hp] [A] µF Vc
PFPBasic 2-50 1 x 220-240 1.05 0.75 1 4.7 20 450

Dimensions and weights


Packing dimensions [mm] Volume Weight
Model A B C E F G I H H1 H2 DNA DNM
L/A L/B L/H [m3] [kg]
PFPBasic 2-50 301 142 38 136 90 112 7 206 146 187 Rp 1 Rp 1 406 267 402 0.044 10.7