Energy management

26 Automatic transfer switch controllers

Supervision of two or three


three-phase power sources
Emergency demand supervision
for standby generating set
Tie-breaker management
Control of contactors, motorised
circuit breakers and motorised
changeover switches
Closed transition
Automatic non-priority load
management
Event logging
Remote control and supervision
Front optical port
Built-in NFC technology
Expandable with EXP modules
Communication protocols
Modbus-ASCII, RTU and TCP
Real time clock
Enclosed automatic transfer
switches ATS.

SEC. - PAGE
Automatic transfer switch controllers for 2 power sources
ATL 100 type modular version for controlling 2 power sources with single phase control ...................................... 26 - 6
ATL 600 and ATL 601 type non expandable for controlling 2 power sources............................................................ 26 - 6
ATL 610 type expandable with EXP modules for controlling 2 power sources ......................................................... 26 - 6
ATL 800 type expandable with EXP modules for controlling 2 power sources and 1 tie breaker ............................. 26 - 7
Automatic transfer switch controllers for 3 power sources
ATL 900 type expandable with EXP modules for controlling 3 power sources and 2 tie breakers ........................... 26 - 8
Enclosed automatic transfer switches ATS
ATP series with ATL 600 automatic transfer switch controller and contactors ........................................................ 26 - 9
Accessories
Dual power supply module ....................................................................................................................................... 26 - 10
Communication devices, software and accessories ................................................................................................. 26 - 11

Dimensions ............................................................................................................ 26 - 12
Wiring diagrams ...................................................................................................... 26 - 13
Technical characteristics ............................................................................................ 26 - 16
26

Page 26-6 Page 26-6 Page 26-6

ATL 100 ATL 600 - ATL 601 ATL 610


• Modular housing • Management of two power sources • Management of two power sources
• Management of two power sources • AC or DC power supply • AC and DC power supply
• Single phase control. • 6 programmable digital inputs • 6 programmable digital inputs
• 7 programmable relay outputs. • 7 programmable relay outputs
• Real time clock (RTC)
• Expandable with EXP series modules
(inputs and outputs, communication ports).

Page 26-7 Page 26-8 Pag. 26-9

ATL 800 ATL 900 ATP


• Management of 2 power sources and 1 tie • Management of 3 power sources and 2 tie • Enclosed automatic transfer switches from
breaker breakers 45 to 160A
• AC and DC power supply • AC and DC power supply • Management of 2 power sources
• 8 programmable digital inputs • 12 programmable digital inputs • Four-pole interlocked contactors
• 7 programmable relay outputs • 10 programmable relay outputs • Automatic transfer switch controller type
• Built-in NFC technology for parameter settings • 1 programmable static output ATL 600
with APP • Built-in NFC technology for parameter • Dual power supply module type ATL DPS1
• Real time clock (RTC) settings with APP for the measurement and control of voltages
• Non-priority load management • Real time clock (RTC) present at supply inputs
• Closed transition with brief parallel • Non-priority load management • Miniature circuit breakers for the protection
configuration of the measuring lines
• Closed transition with brief parallel
• Built-in RS485 communication configuration • Metallic enclosure IP65.
• Built-in PLC logic • Built-in RS485 communication
• Expandable with EXP series modules (inputs • Built-in PLC logic
and outputs, communication ports). • 4 current inputs
• Expandable with EXP series modules
(inputs and outputs, communication ports).

Page 26-10

ATL DPS1
• Module specifically designed to control
power supply voltage of motorised circuit
breakers and changeover switches
• Continuous monitoring of supply line status
• Management via microcontroller
management.
26 Automatic transfer switch controllers
ATL series

ATL 100 ATL 600 - ATL 601 ATL 610 ATL 800 ATL 900
POWER SUPPLY
Rated DC supply voltage –– 12/24VDC (ATL 601) 12/24VDC 12/24/48VDC 12/24/48VDC
Rated AC supply voltage 110...230VAC 110...240VAC (ATL 600) 110...240VAC 110...240VAC 110...240VAC
Frequency 45...66Hz 45...66Hz 45...66Hz 45...66Hz 45...66Hz
FRONT PANEL / HOUSING
Backlit display –– LCD graphic 128x80 pixel LCD graphic 128x80 pixel LCD graphic 128x80 pixel LCD graphic 128x112 pixel
Languages –– 5 5 8 8
Size Modular housing (3U) 144x144x52.2mm/ 144x144x52.2mm/ 240x180x45mm/ 240x180x45mm/
5.67x5.67x2.05” 5.67x5.67x2.05” 9.45x7.09x1.77” 9.45x7.09x1.77”
Degree of protection IP40 on front / IP40 / optional IP65 IP40 / optional IP65 IP65 IP65
IP20 terminals
Expandable with EXP series modules –– –– 2 modules 3 modules 3 modules
VOLTAGE AND CURRENT MEASUREMENT INPUT
Power sources that can be controlled –– 2 2 2 3
Voltage inputs per line 1 phases + neutral 3 phases + neutral 3 phases + neutral 3 phases + neutral 3 phases + neutral
Rated voltage Ue 110...230VAC 480VAC 480VAC 600VAC 600VAC
Current inputs –– –– –– –– 4 (by 5A or 1A CTs)
Frequency range 45…65Hz 45…65Hz 45…65Hz 45…65Hz 45…65Hz
BUILT-IN DIGITAL INPUTS AND OUTPUTS
Number of inputs –– 6 6 8 12
Number of outputs 3 7 7 7 11
Contact configuration 3 NO 6 NO + 1 changeover 6 NO + 1 changeover 4 NO + 3 changeover 6 NO + 4 changeover +
1 SSR
INTERFACE
Programming with NFC technology –– –– ––  
Front optical USB communication port ––  with CX 01  with CX 01  with CX 01  with CX 01
Front optical Wi-Fi communication port ––  with CX 02  with CX 02  with CX 02  with CX 02
USB communication –– ––  EXP10 10  EXP10 10  EXP10 10
RS232 communication –– ––  EXP10 11  EXP10 11  EXP10 11
RS485 communication –– ––  EXP10 12  (built-in)  (built-in)
Ethernet communication –– ––  EXP10 13  EXP10 13  EXP10 13
Profibus communication –– ––  EXP10 14  EXP10 14  EXP10 14
Communication via modem –– –– ––  EXP10 15  EXP10 15
FUNCTIONS
Number of tie breakers that can be managed –– –– –– 1 2
Programmable source type (utility or generation) ––    
Closed transition –– –– ––  
Non-priority load management –– –– ––  
Switching management with power thresholds –– –– –– –– 
PLC logic –– –– ––  
Timers –– –– ––  
System layout available on display –– –– –– 6 14
Custom system layouts –– –– ––  
User alarms ––    
Limits ––    
Event logging –– 100 100 250 250
Real time clock with backup reserve energy –– ––   
Acoustic alarms –– –– ––  
Analogue inputs –– –– ––  EXP10 04  EXP10 04
Analogue outputs –– –– ––  EXP10 05  EXP10 05
Accessory for alarm remoting –– –– –– ––  RGK RR

26-2
26 Automatic transfer switch controllers
For 2 power sources
ATL 600 - ATL 601 - ATL 610

NON-STOP CONTROL!
BACKLIT GRAPHIC
LCD DISPLAY
128x80 pixel, with excellent
legibility with adjustable
brightness and display of
events, alarms and
measurements in 5
languages: English, Italian,
French, Spanish and
German.

OPTICAL COMMUNICATION
PORT
The optical port on the front, using a standard
USB or Wi-Fi point, permits to communication
with a PC, smartphone and tablet, to carry out
programming, diagnostics and data download
without removing power to the electric panel.

COMPACT SIZE FIXING SYSTEM INPUTS, OUTPUTS, INTERNAL VARIABLES, COUNTERS


The inputs and outputs can be configured by the user to manage the various
application requirements. Also available to the user are limit thresholds,
counters, user alarms and remote control variables (ATL 610 only) to
customise the control functions. The limit and counter statuses, if enabled, are
shown in the appropriate pages on the display.

CALENDAR CLOCK (ATL 610)


Built-in calendar-clock with backup reserve power.

DUAL POWER SUPPLY (ATL 610)


110...240VAC and 12/24VDC supply.

EXPANDABILITY (ATL 610)


Basic functions of the transfer switch controllers can be easily extended using
EXP series expansion modules:
44mm - Relay outputs
1.73” - Digital and analogue inputs and outputs
9mm - Opto-isolated RS232 interface
0.35” - Opto-isolated RS485 interface
- Opto-isolated Ethernet interface.
Using modules dedicated to communications the device can be controlled and
supervised by the and softwares and controlled remotely
and configured with the software.

The fixing system with metal


Slim frame profile and reduced
screws guarantees excellent, lasting
total depth simplify installation of
hold over time.
the transfer switch controller also in
very compact electric panels.
STATISTICS AND EVENTS
The recorded statistical data is
HIGH PROTECTION DEGREE
available to the user for
The controller front and the optional
understanding how the system
frame seal have been designed to
operates. A cyclical internal memory
warrant an IP65 protection degree.
records up to 100 events.
26
MAINTENANCE COUNTERS
EMERGENCY DEMAND MAX
ATL features two counters used for 2
maintenance; the first monitors the SUPERVISION FOR STANDBY
operating time and the second GENERATING SET
counts the number of switching In applications where one of the two
operations. Exceeding the limit set supply sources is a generating set,
on the counters activates the the transfer switch controller has
corresponding alarm. specific functions to supervise the
generator starting and stopping
operations.
12/24VDC battery supply input

26-3
26 Automatic transfer switch controllers
For 2 and 3 power sources
ATL 800 - ATL 900

VERSATILE CONFIGURATION
ATL
A
AT L 800
Management of 2 energy sources and 1 tie breaker.
6 preconfigured
preconfigur system layouts.
Non-priority load
l management.
Management of transition with brief parallel configuration.
RS485 built in.
in
Built-in NFC technology
t for parameter settings with
APP .
App and software:
soft
f , , , , .

GRAPHIC LCD AND 8-LANGUAGE INPUTS, OUTPUTS, INTERNAL STATISTICS AND EVENTS PROGRAMMABLE PLC LOGIC
TEXT VARIABLES, COUNTERS The statistical data recorded by the With the built-in PLC functions, new
The backlit graphic display simplifies The input and output functions are transfer switch controller is switching logic can be defined
the user interface and permits good preconfigured with the most available to the user for analysing through appropriate combinations
visibility in environments with poor frequently used settings; the user the performance of the switching of input, output and internal variable
lighting. For ATL 800 and ATL 900 can easily modify the predefined system. A cyclical internal memory signals.
the texts are available in 8 configuration and adapt the switch records up to 250 events, providing
languages: English, Italian, French, to their application requirements. useful information on the history of
Spanish, German, Portuguese, All the inputs and outputs can be the system controlled. TIMER
Polish and Russian. configured. There are various types 8 timer variables are available for
The new interface allows the user to of programmable internal variables: use in the system’s PLC logic, in
see, clearly and simply: - Limit thresholds BUILT-IN CALENDAR CLOCK combination with the outputs or
- System status - Remote control variables A built-in calendar clock with user alarms. Each timer variable has
- Measurements - User alarms backup reserve energy permits each an input variable that controls it.
- Statistical data - Programmable counters event to be identified using the time When this variable changes state,
- Threshold control - Timer. and date on which it occurred. so does the timer variable, but it
- Alarm pop-up windows. The limit, counter and enabled timer remains in the new state only for the
statuses are available for display on time specified then returns
dedicated pages. automatically to the starting
BUILT-IN RS485 COMMUNICATION
condition.
Thanks to the built-in RS485
communication port, ATL 800 and
ATL 900 are already set up for NFC CONNECTION
remote supervision and control. Programming the parameters via
In addition to this communication tablet and smartphone is now
port, the user can install two further possible also through NFC wireless
types of communication from those technology.
available in the EXP… expansion Bringing a smartphone or tablet
MAINTENANCE COUNTERS modules. with NFC connection enabled close
Two counters can be used for to the display of the ATL 800-900
scheduling maintenance on the activates the APP and the
transfer systems installed: the first DUAL AC/DC SUPPLY switch connected is recognised
for recording the operating time and ATL switches can deal with all automatically. It will then be
the second for monitoring the supply solutions demanded by the possible to modify the parameters
number of switching operations. market. The best and safest solution and program the ATL.
Exceeding the limit set on the is the simultaneous use of AC and
counters activates the DC supply. The switches can then
corresponding alarm. be supplied by the AC line available USB AND WI-FI COMMUNICATION
and, during switching, in the INTERFACES
absence of the AC line, the switch ATL 800 and ATL 900 feature a front
will be supplied by the battery via optical port for programming via
HIGH PROTECTION RATING the DC inputs. Non-stop control! optional USB (CX 01) or Wi-Fi
The controller front and the frame AC supply ensures supply during (CX 02) communication interface.
seal have been designed to warrant system monitoring and DC supply Advantages:
an IP65 protection degree. guarantees constant supply during - Not necessary to disconnect the
switching. supply from the panel to connect
to the switch
- Electrical safety (no physical
connection)
- Convenience of operating on the
front.

26-4
26 Automatic transfer switch controllers
For 2 and 3 power sources
ATL 800 - ATL 900

FULL OPTIONAL, FOR EVERY REQUIREMENT


ATL 900
Management of 3 energy power sources and 2 tie breakers.
4 current inputs for the three phases and neutral.
14 preconfigured system layouts.
Non-priority load management.
Management of transition with brief parallel configuration.
RS485 built in.
Built-in NFC technology for parameter settings with APP .
App and software: , , , , .

WI-FI COMMUNICATION THREE TYPES OF TRANSITION AVAILABLE


INTERFACE (VIA CX 02) Open transition In-phase transition Closed transition
This connection can be used to: The switch transfers the load between The switch transfers the load between With switches and external protections,
- Copy the parameters the two sources, interrupting the the two sources, interrupting the configured appropriately, the two
All the parameters of the ATL can supply for a period of time that can be supply for a period of time that can be sources will be synchronised (where
be saved in the CX 02 memory and programmed by the user. programmed. In this case the load is possible) or spontaneous
if necessary loaded back into the passed to a new source if spontaneous synchronisation will be expected within
same device (backup function) or synchronisation is found; a limit time. In presence of all
a new switch (replication of the the amplitude, phase and frequency of synchronisation conditions the load will
configuration). the two sources must not differ from be transferred with closed transition
- Clone the device settings the maximum value set. and instantaneous parallel without
In addition to copying the interrupting supply.
parameters, the current values of
the statistical data, counters and
events can be saved in the
memory in order to completely
replicate an ATL on another device
of the same type or restore the
ATL to a previously saved state.

ATL 900: management of three sources and two tie breakers EXPANDABILITY
A single transfer switch controller can ATL 800 and ATL 900 functionality
be used to manage applications which can be extended thanks to the
in the past required several transfer EXP… series expansion modules.
switch controllers in a cascade Three expansion slots are available,
connection. and while the switch is restarting
24 system layouts are available. the modules are recognised and
configured entirely automatically.
4 current inputs The following EXP… modules are
The current inputs permit the available:
monitoring of the demand load and - Digital I/O modules EXP10...
defining of the correct switching - Analogue I/O modules
strategy. Knowing the power demanded - USB, RS232, RS485, Ethernet and
by the system and the rated power of Profibus communication modules
the sources, ATL900 can select the best - GPRS/GSM modem.
Since the additional modules are
source available that can supply the
loads correctly. shared with other LOVATO Electric 26
products, it is possible to save in
management costs, guaranteeing
flexibility and ease of installation,
above all when the system has
already been commissioned.
MAX
3

26-5
26 Automatic transfer switch controllers
For 2 power sources

Non expandable Order code Description Qty Wt General characteristics ATL 100
per ATL 100 is a single phase automatic transfer switch controller in
pkg modular housing. It monitors 2 single phase voltage inputs and it
connects to the output the line that is within the limits.
n° [kg] The priority line is the line 1. The 2 outputs can control contactors
ATL 100 Automatic transfer switch 1 0.300 or motorized changeover switches to perform the transfer
controller for 2 power between the lines.
sources with single phase
control, modular housing, Operational characteristics ATL 100
110…230VAC supply – Self-powered
ATL 600 Automatic transfer switch 1 0.600 – Input voltage range: 80…300VAC
ATL 100 – Frequency range: 45…66Hz
controller with LCD display and
optical port for 2 power sources – 2 relay outputs with 1 NO contact 4A 250VAC
with three phase control – 1 relay output with 1 NO contact 3A 250VAC
(144x144mm/5.7x5.7”),
110...240VAC supply General characteristics ATL 600 - ATL 601 - ATL 610
The automatic transfer switch controllers ATL 600 / ATL 601 /
ATL 601 Automatic transfer switch 1 0.600 ATL 610 are used for the automatic or manual switching of the
controller with LCD display and load from the MAIN LINE to a stand-by or emergency SECONDARY
new optical port for 2 power sources
with three phase control
LINE and vice versa. They have two outputs for the “automatic”
and/or “manual” control of contactors or motorised circuit
(144x144mm/5.7x5.7”), breakers and switches.
12/24VDC supply The main features are:
– Supply input
• Single in AC for ATL 600
ATL 600 • Single in DC for ATL 601
• Dual in AC and DC for ATL 610
– Measurement inputs for three phase + neutral voltage values;
Expandable with Order code Description Qty Wt also suitable for 1 and 2 phase lines
per – 128x80 backlit graphic LCD to view measurements, events
EXP… modules pkg and alarms in 5 languages (English, Italian, French, Spanish
and German)
n° [kg] – 2 status indication LEDs
ATL 610 Automatic transfer switch 1 0.680 – 6 programmable digital inputs
controller with LCD display and – 7 programmable relay outputs
optical port for 2 power sources – Viewing of L-L and L-N voltage values of the controlled lines
with three phase control – Status viewing of contactor or motorised circuit breakers and
(144x144mm/5.7x5.7”), switches
110...240VAC supply and – Configuration programming of lines, control and supervision
12/24VDC, expandable with parameters for emergency demand of generating set
EXP… series modules – Event logging
– Microprocessor supervision of functions; including virtual real
time clock for ATL 610
– Communication interface by front optical port with CX 01 or
ATL 610 Order code Description CX 02 dongle using USB or Wi-Fi
– Compatible with and , supervision and
EXPANSION MODULES FOR ATL 610 energy management software, remote control and
Snap on fixing of two modules on ATL 610 rear. configuration software and with the application for
Inputs and outputs. Android/iOS
– Modbus-RTU, ASCII and TCP communication protocol.
EXP10 00 4 opto-isolated digital inputs
EXP10 01 4 opto-isolated static outputs CONTROL FUNCTIONS OF THE LINES
EXP10 02 2 digital inputs and 2 static outputs, – Phase sequence and phase loss
opto-isolated – Minimum and maximum voltage
– Voltage asymmetry
EXP10 03 2 relay outputs 5A 250VAC – Minimum and maximum frequency.
EXP10 06 2 relay outputs, normally open contact
EXP10... 5A 250VAC Operational characteristics ATL 600 - ATL 601 - ATL 610
EXP10 07 3 relay outputs, normally open contact – Power supply
5A 250VAC • Power supply voltage: 110...240VAC (ATL 600);
12...24VDC (ATL 601); 12...24VDC/110...240VAC (ATL 610)
EXP10 08 2 opto-isolated digital inputs and 2 5A relay
– Voltage measurement inputs
outputs 250VAC • Rated voltage Ue: 100...480VAC (L-L)
Communication ports. • Measuring range: 50...576VAC (L-L)
EXP10 10 Opto-isolated USB interface • Frequency range: 45...65Hz.
– Programmable digital inputs
EXP10 11 Opto-isolated RS232 interface • Negative inputs
EXP10 12 Opto-isolated RS485 interface – Programmable relay outputs
EXP10 13 Opto-isolated Ethernet interface • 5 each with 1 normally open contact (NO - SPST) rated 8A
250VAC
EXP10 14 Opto-isolated Profibus-DP interface • 2 each with 1 changeover contact (NO/NC - SPDT) rated 8A
250VAC
EXP... expansion modules fixing on ATL 610 – Enclosure
• Flush-mount housing: 144x144mm/5.7x5.7”
• IEC degree of protection: IP40 on front; IP65 with optional
seal EXP80 01; IP20 at rear.

Certifications and compliance


Certifications obtained: cULus (ATL 601 pending), RCM (only for
ATL 600 - ATL 610), EAC.
Compliant with standards: IEC/EN 60947-1,
IEC/EN 60947-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3,
MAX UL508, CSA C22.2 n°14.
2

Accessories Dimensions Wiring diagrams Technical characteristics


26-6 page 26-10 and 11 page 26-12 page 26-13 page 26-16
26 Automatic transfer switch controllers
For 2 power sources

Expandable with Order code Description Qty Wt General characteristics


per The automatic transfer switch controller ATL 800 is used for
EXP… modules pkg the automatic or manual switching of the load between two
lines in accordance with the selected switching logic. It has
n° [kg] outputs for the “automatic” and/or “manual” control of
ATL 800 Automatic transfer switch 1 1.000 contactors or motorised circuit breakers and switches.
controller (240x180mm/ It can also manage a third control device as tie breaker or
9.45”-7.09”) with LCD display, non-priority load management. The layout and system status
optical port and NFC for 2 lines are displayed directly on the graphic LCD.
control and 1 tie breaker, The main features are:
110...240VAC supply and – AC and DC supply inputs
12/24/48VDC, expandable – Measurement inputs for three phase + neutral voltage
with EXP… series modules values; also suitable for 1 and 2 phase lines
– 128x80 backlit graphic LCD to view measurements, events
ATL 800 and alarms in 8 languages (English, Italian, French,
Spanish, German, Portuguese, Polish and Russian)
– Active operating mode indicator LED
– Viewing of L-L and L-N voltage values of the controlled
lines
– Viewing the status of contactors or motorised circuit
Order code Description breakers both via display and LED
– 6 system layouts available
EXPANSION MODULES. – Management of a tie breaker
Snap on fixing of three modules on rear of ATL 800. – 8 programmable digital inputs
Digital inputs and outputs. – 7 programmable relay outputs
EXP10 00 4 opto-isolated digital inputs – Viewing of L-L and L-N voltage values of the controlled
lines
EXP10 01 4 opto-isolated static outputs – Configuration programming of lines, type of source
EXP10 02 2 digital inputs and 2 static outputs, (line/generator), control and supervision parameters for
opto-isolated emergency demand of generating set
EXP10... – Possibility of transferring load with closed transition and
EXP10 03 2 relay outputs 5A 250VAC
spontaneous or controlled genset synchronisation
EXP10 06 2 relay outputs, normally open contact – Non-priority load management
5A 250VAC – Built-in programmable PLC logic
EXP10 07 3 relay outputs, normally open contact – Built-in RS485 communication
5A 250VAC – Event logging
EXP10 08 2 opto-isolated digital inputs and 2 5A relay – Virtual calendar clock (RTC)
outputs 250VAC – Communication interface by front optical port with CX 01
or CX 02 dongle using USB or Wi-Fi
Analogue inputs and outputs. – Parameter programming via NFC technology and the App
EXP10 04 2 opto-isolated analogue inputs 0/4...20mA or
PT100 or 0...10V or 0...+-5V – Compatible with and , supervision and
EXP10 05 2 opto-isolated analogue outputs 0/4...20mA or energy management software, remote control
0...10V or 0...+-5V and configuration software and with the application
for Android/iOS
Communication ports. – Modbus-RTU, ASCII and TCP communication protocol.
EXP10 10 Opto-isolated USB interface
EXP10 11 Opto-isolated RS232 interface CONTROL FUNCTIONS OF THE LINES
– Phase sequence and phase loss
EXP10 12 Opto-isolated RS485 interface – Minimum and maximum voltage
EXP10 13 Opto-isolated Ethernet interface – Voltage asymmetry
EXP10 14 Opto-isolated Profibus-DP interface – Minimum and maximum frequency.

Operational characteristics
EXP… expansion module fixing on ATL 800 – Power supply
• Power supply voltage: 100...240VAC;
12/24/48VDC
– Voltage measurement inputs
• Rated voltage Ue: 100...600VAC (L-L)
• Frequency range: 45...65Hz.
– Programmable digital inputs
• Negative inputs
– Programmable relay outputs
• 2 each with 1 normally open contact (NO - SPST) rated
12A 250VAC
MAX • 2 each with 1 normally open contact (NO - SPST) rated
3 8A 250VAC
• 3 each with 1 changeover contact (NO/NC - SPDT)
8A 250VAC
– Enclosure
• Flush-mount housing: 180x240mm/5.7x5.7”
• IEC degree of protection: IP65 on front; IP20 at back.

Certifications and compliance 26


Certifications obtained: cULus, EAC, RCM.
Compliant with standards: IEC/EN 61010-1,
IEC/EN 61010-2, IEC/EN 61000-6-2, IEC/EN 61000-6-4,
IEC/EN 60947-1, IEC/EN 60947-6-1, UL508 and
CSA C22.2 n° 14.

Accessories Dimensions Wiring diagrams Technical characteristics


page 26-10 and 11 page 26-12 page 26-14 page 26-16 26-7
26 Automatic transfer switch controllers
For 2 power sources

Expandable with Order code Description Qty Wt General characteristics


per The automatic transfer switch controller ATL 900 is used for
EXP… modules pkg the automatic or manual switching of the load between three
lines in accordance with the selected switching logic. It has
n° [kg] outputs for the “automatic” and/or “manual” control of
ATL 900 Automatic transfer switch 1 1.800 contactors or motorised circuit breakers and switches. It can
controller (240x180mm/ also manage two more control devices as tie breakers or
9.45”-7.09”) with LCD display, non-priority load management. It has four current inputs for
optical port and NFC for 3 lines managing switching with power thresholds. The layout and
control and 2 tie breakers, system status are displayed directly on the graphic LCD.
110...240VAC supply and The main features are:
12/24/48VDC, expandable – AC and DC supply inputs
with EXP… series modules – Measurement inputs for three phase + neutral voltage
values; also suitable for 1 and 2 phase lines
– 4 current measurement inputs
ATL 900
– 128x112 backlit graphic LCD to view measurements,
events and alarms in 8 languages (English, Italian, French,
Spanish, German, Portuguese, Polish and Russian)
– Active operating mode indicator LED
– Viewing of L-L and L-N voltage values of the controlled
lines
Order code Description – Viewing the status of contactors or motorised circuit
breakers both via display and LED
EXPANSION MODULES. – 6 system layouts available
– Management of a tie breaker
Snap on fixing of three modules on rear of ATL 900.
– 12 programmable digital inputs
Digital inputs and outputs.
– 10 programmable relay outputs
EXP10 00 4 opto-isolated digital inputs – 1 static output
EXP10 01 4 opto-isolated static outputs – Viewing of L-L and L-N voltage values of the controlled
lines
EXP10 02 2 digital inputs and 2 static outputs, – Configuration programming of lines, type of source
EXP10... opto-isolated (line/generator), control and supervision parameters for
EXP10 03 2 relay outputs 5A 250VAC emergency demand of generating set
EXP10 06 2 relay outputs, normally open contact – Possibility of transferring load with closed transition and
spontaneous or controlled genset synchronisation
5A 250VAC
– Non-priority load management
EXP10 07 3 relay outputs, normally open contact – Built-in programmable PLC logic
5A 250VAC – Built-in RS485 communication
EXP10 08 2 opto-isolated digital inputs and 2 5A relay – Event logging
outputs 250VAC – Virtual calendar clock (RTC)
– Communication interface by front optical port using USB
Analogue inputs and outputs. CX 01 or Wi-Fi CX 02 dongle
EXP10 04 2 opto-isolated analogue inputs 0/4...20mA or – Parameter programming via NFC technology and the App
PT100 or 0...10V or 0...+-5V
EXP10 05 2 opto-isolated analogue outputs 0/4...20mA or – Compatible with and , supervision and
0...10V or 0...+-5V energy management software, remote control
and configuration software and with the
Communication ports. application for Android/iOS
EXP10 10 Opto-isolated USB interface – Modbus-RTU ASCII and TCP communication protocol.
EXP10 11 Opto-isolated RS232 interface CONTROL FUNCTIONS OF THE LINES
EXP10 12 Opto-isolated RS485 interface – Phase sequence and phase loss
– Minimum and maximum voltage
EXP10 13 Opto-isolated Ethernet interface
– Voltage asymmetry
EXP10 14 Opto-isolated Profibus-DP interface – Minimum and maximum frequency.
EXP10 15 GPRS/GSM modem Operational characteristics
– Power supply
EXP… expansion module fixing on ATL 900 • Power supply voltage: 100...240VAC;
12/24/48VDC
– Voltage measurement inputs
• Rated voltage Ue: 100...600VAC (L-L)
• Frequency range: 45...65Hz.
– Programmable digital inputs
• Negative inputs
– Programmable relay outputs
• 3 each with 1 normally open contact (NO - SPST) rated
12A 250VAC
• 3 each with 1 normally open contact (NO - SPST) rated
8A 250VAC
MAX • 4 each with 1 changeover contact (NO/NC - SPDT)
3 8A 250VAC
• 1 30VDC 50mA static output
– Enclosure
• Flush-mount housing: 180x240mm/5.7x5.7”
• IEC degree of protection: IP65 on front; IP20 at back.
, , , and software
and APP
See section 29.
EXP expansion modules
See page 30-2.
Certifications and compliance
Certifications obtained: cULus, EAC, RCM.
Compliant with standards: IEC/EN 61010-1,
IEC/EN 61010-2, IEC/EN 61000-6-2, IEC/EN 61000-6-4,
IEC/EN 60947-1, IEC/EN 60947-6-1, UL508 and
CSA C22.2 n° 14.

Accessories Dimensions Wiring diagrams Technical characteristics


26-8 page 26-10 and 11 page 26-12 page 26-15 page 26-16
26 Automatic transfer switch controllers
Enclosed automatic transfer switches ATS

Order code Opera- Power Dimensions General characteristics


ting (400V) (HxWxD) The enclosed automatic transfer switches ATP series are
current provided in metallic enclosure IP65, complete with automatic
new AC1 transfer switch controller type ATL 600, four-pole contactors
BF series, dual power supply module type ATL DPS1 and
[A] [kVA] [mm (in)] miniature circuit breakers (MCB) type P1 MB for the
Auxiliary supply 230VAC, with four-pole contactors versions. protection of the measuring lines.
ATP 0045 T4 A230 C 600 A 45 31 500x400x200 They are used for the automatic or manual switching of the
(19.68x15.75x7.87”) load between two lines (“MAIN LINE” and “SECONDARY
LINE”).
ATP 0060 T4 A230 C 600 A 60 42 500x400x200 They are available in versions from 45 to 160A in four-pole
(19.68x15.75x7.87”) configuration.
ATP 0080 T4 A230 C 600 A 80 55 500x400x200
(19.68x15.75x7.87”) CONTROL FUNCTIONS OF THE LINES
ATP 0100 T4 A230 C 600 A 100 69 500x400x200 – Phase sequence and phase loss
(19.68x15.75x7.87”) – Minimum and maximum voltage
– Voltage asymmetry
ATP 0125 T4 A230 C 600 A 125 87 600x400x250 – Minimum and maximum frequency.
(23.62x15.75x9.84”)
ATP 0160 T4 A230 C 600 A 160 111 600x400x250 Operational characteristics
(23.62x15.75x9.84”) – Power supply
• Auxiliary supply voltage: 230VAC (taken from the input
lines)
– Voltage measurement inputs
• Rated voltage Ue: 100…480VAC (L-L)
ATP... • Measuring range: 50…576VAC (L-L)
• Frequency range: 45…65Hz
– 6 programmable digital inputs
– 7 programmable relay outputs:
• 6 each with 1 normally open contact (NO-SPST) rated 8A
250VAC
• 1 with 1 changeover contact (NO/NC – SPDT) rated 8A
250VAC
– Enclosure:
• Metallic enclosure
• Flanges for cable entries in the top and bottom sides
• PVC locking system with double-comb tool insert
• Opening with left hinges
• IEC degree of protection: IP65.

Compliance
Compliant with standards: IEC 60947-6-1, IEC 60947-4-1.

MCBs for the protection of the


measuring lines P1 MB series

Dual power supply module type


ATL DPS1

Automatic transfer
switch controller type
ATL 600

26

Four-pole interlocked contactors


BF series

Terminal blocks

Accessories Dimensions
page 26-10 and 11 page 26-12 26-9
26 Automatic transfer switch controllers
Accessories

Dual power supply module Order code Description Qty Wt General characteristics
per ATL DPS1 is capable of measuring and controlling voltages
pkg at its inputs selecting the most ideal to connect to the output.
It is suitable to supply motorised circuit breakers and
n° [kg] changeover switches in automatic switching systems of 2
ATL DPS1 For controlling and 1 0.300 three phase supply lines.
selecting supply for The two voltage inputs of the module are independent and
contactors 110...230VAC insulated; each is capable of supplying the internal
configurable measuring circuit managed by the microcontroller.
It reduces the number of components and improves
installation safety.
Main ATL DPS1 features include:
– Voltage value selectable via bypass terminals
– Minimum and maximum voltage tripping thresholds
– 2 single phase L+N inputs
– 1 single phase L+N output
– L1 priority line
ATL DPS1
– Use with motorised control units powered at 110VAC or
230VAC
– Output voltage monitoring
– Internal relay self-diagnosis
– Indicating LEDs for abnormal conditions and status of
110VAC 230VAC inputs and outputs.
MIN MAX MIN MAX Operational characteristics
Line absent < 88V > 152V < 176V > 288V – Rated supply voltage: 110...230VAC configurable
– Frequency: 50/60Hz
Line present < 92V > 144V < 185V > 273V – Input voltage range: 80…300VAC
– Voltage tripping thresholds min / max: 80% and 120% of
Using the thresholds above ATL DPS1 outputs one of the power supplies available according to the logic preset value
shown in the table: – 2 line inputs L1-L2: Single phase, between phase and
neutral
Status LED Status LED Output LED ATL DPS1 Alarm LED – Current output: 4A max
Line 1 Line 1 Line 2 Line 2 Output contact Fault – Priority line: L1 when both input values are within limits
– Fixed delay time between line switching: 0.5s
OK ON <MIN OR >MAX OFF ON - from line 1 ON ON - OK Closed OFF – 4 status indication LEDs for voltage of each line within
OK ON OK ON ON - from line 1 ON ON - OK Closed OFF limits, voltage present at output, relay output anomaly
<MIN OR OFF OK ON ON - from line 2 ON ON - OK Closed OFF – Mounting: 35mm DIN rail (IEC/EN 60715)
>MAX or screw-type by means of removable clips
– Modular housing, 3 module
<MIN OFF <MIN OFF OFF OFF OFF Open OFF – IEC degree of protection: IP40 on front; IP20 at rear.
>MAX OFF <MIN OR >MAX OFF OFF OFF ON Open ON
Certifications and compliance
<MIN OR OFF >MAX OFF OFF OFF ON Open ON
Certifications obtained: cULus, EAC, RCM.
>MAX
Compliant with standards: IEC/EN 61010-1,
OK ON ON - Fault IEC/EN 61010-2, IEC/EN 61000-6-2, IEC/EN 61000-6-4,
>MIN ON OFF OFF Open ON
<MIN OR >MAX OFF Internal relays IEC/EN 60947-1, IEC/EN 60947-6-1, UL508 and
C22.2 n° 14.
OK ON Open ON
<MIN OR OFF >MIN ON OFF OFF Internal
>MAX relays

Dimensions
26-10 page 26-12
26 Automatic transfer switch controllers
Accessories

Communication devices Order code Description Qty Wt General characteristics


per Communication devices for connection of LOVATO Electric
pkg products to personal computers, smartphones and tablets.
n° [kg] CX 01
The USB/optical dongle, complete with cable, allows the
CX 01 USB/optical dongle with 1 0.090
connection of products compatible with PCs without having
PC  ATL 600/601/610/800/900
to disconnect the power supply from the electric panel.
with optical port for programming,
The PC identifies the connection as a standard USB.
data download, diagnostics and
CX 01 firmware upgrade CX 02
CX 02 Wi-Fi device for connecting 1 0.090 By Wi-Fi connection, compatible LOVATO Electric products
PC  ATL 600/601/610/800/900 can be viewed on PCs, smartphones and tablets with no need
with optical port for programming, for cabling.
data download, diagnostics and CX 03
cloning Antenna compatible with major part of worldwide mobile
CX 03 GSM penta-band antenna 1 0.090 networks thanks to the use of 850/900/1800/1900/
CX 02 (850/900/1800/1900/2100MHz) 2100MHz frequencies.
for EXP10 15 expansion module Protection rating IP67. Fixing hole Ø10mm/3.94”.
Cable length 2.5mm/0.10”.
For dimensions, wiring schemes and technical characteristics,
refer to technical instructions in Downloads of local or global
websites: www.LovatoElectric.com.
CX 03

Software and accessories Order code Description Qty Wt Software


per By using the software, the quick setup of the switch
pkg controllers can be carried out via PC, avoiding parameter
programming errors.
n° [kg] The parameter programming of ATL 600/601/610/800/900
EXP80 01 Protective seal IP65 1 0.150 controllers can also be PC saved and quickly uploaded into
for ATL 600/601/610 another device requiring the same programming.
For ATL 610 - ATL 800 - ATL 900. It permits the correct operation of the system to be checked
through graphic and numerical display of the measurements
51 C2 Connection cable 1 0.090 and controller status.
51 C4 PC  ATL 610/800/900 with
EXP10 11, length 1.8m and softwares provide for the
supervision of the ATL 600/601/610/800/900 transfer switch
51 C4 Connection cable 1 0.147
controllers.
PC  product RS232/RS485,
This software has structures and applications based on MS
length 1.8m
SQL relational databases, and the data can be consulted
EXC CON 01 RS485/Ethernet converter, 1 0.400 using the most popular browsers.
12…48VDC, including kit It is a highly versatile system, simultaneously accessible to a
for DIN rail fixing large number of users/workstations via intranets, VPN or
EXC M4G 01 RS485 gateway/4G modem, 1 0.340 Internet.
new 9…36VDC, including cable
for programming
See section 29 for details.
APP for smartphone and tablet
EXC CON 01
The (Setup And Maintenance 1) application allows
For ATL 900. the user to program the controller, view alarm conditions,
RGK RR Remote unit for status 1 0.420 send commands, read measurements, download statistical
and alarms, 12/24VDC, data and events and send retrieved data by email.
12 relay outputs, The connection is made by Wi-Fi with a smartphone or tablet
pulse input. using the CX 02 dongle.
It is iOS and Android compatible.
For more details consult our Technical support.

EXC M4G 01 For ATL 800 and ATL 900, featuring built-in NFC technology,
the LOVATO application is available for parameter
programming.
Available only for Android devices.
See section 29 for details.
EXC CON 01
The EXC CON 01 converter allows “Slave” devices connected
on an RS485 network to interface with a “Master” featuring
Ethernet port:
– Kit comprising MOXA NPORT5230 converter and DIN rail
mounting accessory DK35
– Programming via web interface
RGK RR
– Power supply not included.
See section 30 for details.
EXC M4G 01
The EXC M4G 01 gateway allows “Slave” devices connected
26
on an RS485 network to interface with a “Master” via 4G
network.
RGK RR
It is an expansion unit for remoting statuses and alarms.
RGK RR can be connected at a maximum distance of
1000m/39.37” using the static output of the ATL 900.
RGK RR has 12 output relays, 7 normally open
(2.5A 250VAC/C38) and 5 changeover contacts
(5A 250VAC/B300).

26-11
26 Automatic transfer switch controllers
Dimensions [mm (in)]

AUTOMATIC TRANSFER SWITCH CONTROLLERS


ATL 100 ATL 600 - ATL 601 - ATL 610 Cutout
58 (2.28”) 138 (5.43”)
144 (5.67”) 43
53.5 (2.11”) 5 43.7 (1.69”)
(0.20”) (1.72”)
104.7 (4.12”)

45 (1.77”)
98.3 (3.87”)

90 (3.54”)

138 (5.43”)
137 (5.39”)

144 (5.67”)
64.5 (2.54”)
Ø4.2 (0.16”)

73 (2.87”) 9.2
EXP 10... (0.36”)
(2 max)

ATL 800 - ATL 900 Cutout


240 (9.45”) 56.4 (2.22”)
32.6 11.3 220 (8.66”)
(1.28”) (0.44”)
180 (7.09”)

160 (6.30”)
EXP 10...
(2max)

DUAL POWER SUPPLY MODULE EXPANSION UNIT


ATL DPS1 RGK RR
58 (2.28”)
53.5 (2.11”) 5 43.7 19.8 54.2 (2.13”)
(0.20”) (1.72”) (0.78”)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L
H
TR

SG

OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 CAN


104.7 (4.12”)

45 (1.77”)
98.3 (3.87”)

90 (3.54”)

107 (4.21”)
96 (3.78”)
99.6 (3.92”)

OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 ON


D7
D7 D8
D D9
D9 D
D1
D10 D18
D1 D
D2
D27 D2
D2

D2
D20 D2
D29 D2
D28 D19
D1 D21
D2 D3
D30 D2
D22

OUT 7 OUT 8 OUT 9 OUT 10 OUT 11 OUT 12 COM

REMOTE RELAYS UNIT


OUT 8 OUT 9 OUT 10 OUT 11 OUT 12 PULSE IN SUPPLY
+COM

__
+
INP

19 20 21 22 23 24 25 26 27 27 29 30 31 32 33 34 35 36

Ø4.2 (0.16”)
116 (4.57”) 46.5 (1.83”)

ENCLOSED AUTOMATIC TRANSFER SWITCHES ATS ENCLOSED AUTOMATIC TRANSFER SWITCHES ATS
ATP 0045... - ATP 0060... - ATP 0080... - ATP 0100... ATP 0125... - ATP 0160...
400 (15.75”) 200 (8.16”) 400 (15.75”) 250 (9.84”)
500 (19.68”)

600 (23.62”)

26-12
26 Automatic transfer switch controllers
Wiring diagrams

ATL 100
Connection diagrams
R1

N1

R2

N2
S1

S2
T1

T2
F1❶ F2❶
KM1 KM2

ALARM Y1 Y2
KM2 KM1 Open 230V~
Closed 110V~

KM1 KM2
R

N
S

T
L1

L2
N1

N2

F1❶ F2❶

L1

L2
N1

N2
L1/L L1/N L2/L L2/N F1❷ F2❷ F3❶ F4❶
LINE 1 LINE 2

ATL100 KM1 KM2


Automatic Transfer Switch
L1/L L1/N L2/L L2/N
LINE 1 LINE 2
T1/L T1/N T2/L T2/N
ATL100
Automatic Transfer Switch
KM1 Main Generator KM1 Main Generator
Contact Contact Contact Contact
KM2 KM1 T1/L T1/N T2/L T2/N KM2 KM1 Feedback Feedback
Feedback Feedback
KM2 KM1 KM2 KM2
KM2 KM1

KM1 KM2 7 6 5 4
7 6 5 4 KM1 KM2
KM1 KM2

Closing pos. II

Closing pos. I

Open all pos. 0


Closing pos. II

Common +
Closing pos. I

2 3 2 3
Open all pos. 0
Common +

2 3 2 3

2 (N) 2 (N)

Battery Battery
1 (L) - terminal 1 (L) - terminal
1 1 1 1
Pos. I Pos. II Pos. I Pos. II

Position feedback Position feedback


GEX69...C (External GEX10... on GE...E) GEX69...C (External GEX10... on GE...E)
Motorized Control Unit Motorized Control Unit

 4A maximum fuses
 1A maximum fuses

ATL 600 - ATL 601 - ATL 610 


Connection diagrams Connection diagrams
Motorised breaker control Motorised changeover switches control
LINE 1 LINE 2 LINE 1 LINE 2
L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N
QF1 QF1
1 L1 1 L1
2 L2 2 L2
LINE 1 LINE 1
3 L3 3 L3
4 N 4 N

QF2
5 ATL6... QF2
5 ATL6...

ATL600
ATL610
L1 L1
ATL601
ATL610

ATL601
ATL610
ATL600
ATL610

6 L2 6 L2
LINE 2 LINE 2
7 L3 7 L3
8 N 8 N
AC DC AC DC
Q1 Q2 LINE 1 LINE 2 AUX DIGITAL INPUTS SUPPLY SUPPLY Q1 Q2 LINE 1 LINE 2 AUX DIGITAL INPUTS SUPPLY SUPPLY
_ _
INP 1
INP 2
INP 3
INP 4
INP 5
INP 6

INP 1
INP 2
INP 3
INP 4
INP 5
INP 6
~~ + ~~ +
COM

COM
L1 N1 L2 N2 L1 N1 L2 N2
10
11
12
22
23
24

10
11
12
22
23
24
15
16
17
18
19
20
21

15
16
17
18
19
20
21
13
14

31
32

13
14

31
32
25
26
27
28
29
30

25
26
27
28
29
30
9

L L
OUT OUT
N N
DUAL POWER SUPPLY DUAL POWER SUPPLY
L1 L2 L3 N L1 L2 L3 N
LOAD LOAD

Q1
CLOSING 1
CLOSING 2
OPENING ALL
POWER SUPPLY
CLOSING

CLOSING
OPENING

OPENING

1 - 2 OPENED
1 CLOSED

2 CLOSED
POWER SUPPLY

POWER SUPPLY
TRIP COIL

TRIP COIL
TRIP

TRIP
STATUS

STATUS
INTERLOCK

INTERLOCK

Q2
Q1 Q2

 For the correct programming of inputs and outputs, consult the installation manuals available at www.LovatoElectric.com.

26

26-13
26 Automatic transfer switch controllers
Wiring diagrams

ATL 800 
Power connection diagrams Power connection diagrams
Two breakers Two breakers and a tie breaker
LINE 1 LINE 2 LINE 1 LINE 2
L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N
QF1 QF1
1 L1 1 L1
2 L2 2 L2
LINE 1 LINE 1
3 L3 3 L3
4 N 4 N

QF2
5
6
L1
L2
ATL800 QF2
ATL800
5 L1
LINE 2
7 L3 6 L2
8 N LINE 2
7 L3
8 N
BRK1 BRK2

BRK1 BRK2

L1 L2 L3 N TB1
LOAD

L1 L2 L3 N L1 L2 L3 N
LOAD 1 LOAD 2

Control connection diagrams Control connection diagrams


Two breakers Two breakers and a tie breaker

CLOSE LINE 1

CLOSE LINE 2
ATL800 EXP1003

OPEN LINE 1

OPEN LINE 2
ATL800

CLOSE TB1
OPEN TB1
CLOSE LINE 1

CLOSE LINE 2
OPEN LINE 1

OPEN LINE 2

OUT 1

OUT 2

OUT 3

OUT 4
A1 A2 -- +
OUT 1

OUT 2

OUT 3

OUT 4

53 54 26 27 55 56 57 39 40 43 58 59 60 41 44 45 14 12 11 24 22 21

A1 A2 F1A T3.15A
53 54 26 27 55 56 57 39 40 43 58 59 60 41 44
L N - +
AC AUX SUPPLY

12 - 48V=
BATTERY

F1A T3.15A

L N
12 - 48V=
BATTERY
AC AUX SUPPLY

BRK2
INTERLOCK

BRK1
INTERLOCK

BRK1 BRK2 TB1


CLOSING
OPENING

CLOSING

CLOSING
OPENING

OPENING
L
POWER SUPPLY

POWER SUPPLY

POWER SUPPLY
TRIP
INTERLOCK

TRIP

TRIP
INTERLOCK

INTERLOCK
STATUS

STATUS

STATUS
BRK1 BRK2 FROM ATLDPS1
CLOSING
OPENING

CLOSING
OPENING
POWER SUPPLY

POWER SUPPLY
TRIP

TRIP
STATUS

STATUS
INTERLOCK

INTERLOCK

FROM ATLDPS1 N

 For the correct programming of inputs and outputs, consult the installation manuals available at www.LovatoElectric.com.

26-14
26 Automatic transfer switch controllers
Wiring diagrams

ATL 900 
Power connection diagrams Power connection diagrams
Three breakers Three breakers and two tie breakers
LINE 1 LINE 2 LINE 2 LINE 1 LINE 2 LINE 3
L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N
QF1 QF1
1 L1 1 L1
2 L2 2 L2
LINE 1 LINE 1
3 L3 3 L3
4 N 4 N

QF2
5
6
L1
L2
ATL900 QF2
5
6
L1
L2
ATL900
LINE 2 LINE 2
7 L3 7 L3
8 N 8 N

QF3 QF3
9 L1 9 L1
10 L2 10 L2
LINE 3 LINE 3
11 L3 11 L3
12 N 12 N
BRK1 BRK2 BRK3 BRK1 BRK2 BRK3

13 S1-1 13 S1-1
14 S1-2 14 S1-2
15 S1-3 15 S1-3
CURRENT CURRENT
16 S1-4 TB1 TB2 16 S1-4
17 S2 17 S2
TA1

18 S2 18 S2
TA2
TA3
TA4

L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N
LOAD LOAD 1 LOAD 2 LOAD 3

Control connection diagrams


Three breakers
CLOSE LINE 1

CLOSE LINE 2

CLOSE LINE 3

ATL900
OPEN LINE 1

OPEN LINE 2

OPEN LINE 3
OUT 1

OUT 2

OUT 3

OUT 4

OUT 5

OUT 6

A1 A2
53 54 26 27 55 56 57 39 40 43 58 59 60 41 44 61 62 63 42 45

F1A T3.15A

L N
AC AUX SUPPLY

12 - 48V=
BATTERY

BRK2 BRK1 BRK1


INTERLOCK

INTERLOCK

INTERLOCK

BRK3 BRK3 BRK2

BRK1 BRK2 BRK3


OPENING
CLOSING

CLOSING

CLOSING
OPENING

OPENING
POWER SUPPLY

POWER SUPPLY

POWER SUPPLY
INTERLOCK

STATUS

INTERLOCK

INTERLOCK
TRIP

STATUS

STATUS
TRIP

TRIP

FROM ATLDPS1

Control connection diagrams


Three breakers and two tie breakers
EXP1003 EXP1003
CLOSE LINE 1

CLOSE LINE 2

CLOSE LINE 3

ATL900
OPEN LINE 1

OPEN LINE 2

OPEN LINE 3

CLOSE TB1

CLOSE TB2
OPEN TB1

OPEN TB2
OUT 1

OUT 2

OUT 3

OUT 4

OUT 5

OUT 6

A1 A2

53 54 26 27 55 56 57 39 4043 58 59 60 41 44 61 62 63 42 45 50 51 14 12 11 24 22 21 14 12 11 24 22 21
F1A T3.15A

L N
AC AUX SUPPLY

12 - 48V=
BATTERY

BRK1 BRK2 BRK3 TB1 TB2


CLOSING
OPENING

CLOSING

CLOSING

CLOSING

CLOSING
OPENING

OPENING

OPENING

OPENING
POWER SUPPLY

POWER SUPPLY

POWER SUPPLY

POWER SUPPLY

POWER SUPPLY
TRIP
INTERLOCK

STATUS

TRIP

TRIP

TRIP

TRIP
INTERLOCK

INTERLOCK

INTERLOCK

INTERLOCK
STATUS

STATUS

STATUS

STATUS

FROM ATLDPS1

ATL DPS1 
Connection diagram
LINE 1 LINE 2
L N L N
26

ATL DPS1
L N 11 14 Y1 Y2
OUT ALARM OPEN 230V
CLOSED 110V

 For the correct programming of inputs and outputs, consult the installation manuals available at www.LovatoElectric.com.

26-15
26 Automatic transfer switch controllers
Technical characteristics

ATL 100 ATL 600 ATL 601 ATL 610 ATL 800 ATL 900
AC POWER
IEC rated insulation Us 110...230VAC 100...240VAC 12/24VDC 100...240VAC 100...240VAC 100...240VAC
Operating range 80...300VAC 90...264VAC –– 90...264VAC 90...264VAC 90...264VAC
Frequency 45...66Hz 45...66Hz –– 45...66Hz 45...66Hz 45...66Hz
Immunity time for micro-breaking –– ≤25ms (110VAC) ≤25ms (110VAC) ≤40ms (110VAC) ≤40ms (110VAC)
–– ≤250ms (220VAC) ≤250ms (220VAC) ≤200ms (220VAC) ≤200ms (220VAC)
Immunity time for micro-breaking –– –– ≤25ms (110VAC) ≤20ms (110VAC) ≤20ms (110VAC)
(with EXP expansions)
–– –– ≤120ms (220VAC) ≤100ms (220VAC) ≤100ms (220VAC)
DC POWER
Rated battery voltage –– –– 12-24VDC 12-24-48VDC 12-24-48VDC
Operating range –– –– 7.5...33VDC 7.5...57.6VDC 7.5...57.6VDC
Maximum power consumption –– –– 230mA at 12VDC and 400mA at 12VAC; 510mA at 12VAC;
120mA at 24VDC 220mA at 24VDC; 260mA at 24VDC;
100mA at 48VDC 135mA at 48VDC
Maximum power consumption/dissipation –– –– 2.9W 4.W 6.5W
VOLTMETER INPUTS
Max. rated voltage Ue 110...230VAC L-N 480VAC L-L 480VAC L-L 600VAC L-L 600VAC L-L
(277VAC L-N) (277VAC L-N) (346VAC L-N) (346VAC L-N)
Measuring range 80...300VAC 50...576VAC L-L 50...576VAC L-L 50...720VAC L-L 50...720VAC L-L
(333VAC L-N) (333VAC L-N) (415VAC L-N) (415VAC L-N)
Frequency range 45...65Hz 45...65Hz 45...65Hz 45...65Hz 45...65Hz
Measurement method True root mean square True root mean square True root mean square True root mean square True root mean square
(TRMS) (TRMS) (TRMS) (TRMS) (TRMS)
Measuring input impedance >8MΩ L-N >0.5MΩ L-N, >0.5MΩ L-N, >0.55MΩ L-N, >0.55MΩ L-N,
>1.0MΩ L-L >1.0MΩ L-L >1.10MW L-L >1.10MW L-L
Connection method 1 phase and neutral One-phase, two-phase, three-phase line with or without neutral and balanced three-phase
AMMETER INPUTS
Rated current Ie –– –– –– –– 1A~ o 5A~
Measuring range –– –– –– –– for 5A scale: 0.02 - 6A~
for 1A scale: 0.02 - 1.2A ~
Type of input –– –– –– –– Shunt supplied by current
transformer external
(low voltage) 5A max.
Measurement type –– –– –– –– True root mean square
(TRMS)
Overload capacity –– –– –– –– -20% Ie
Overload peak –– –– –– –– 50A for 1 second
Burden –– –– –– –– <0.6VA
MEASUREMENT ACCURACY
Mains and genset voltage ±0.25% f.s. ±1 digit ±0.25% f.s. ±1 digit ±0.25% f.s. ±1 digit ±0.25% f.s. ±1 digit ±0.25% f.s. ±1 digit
DIGITAL INPUTS
Number of inputs –– 6 6 8 12
Type of input –– Negative Negative Negative Negative
Input current –– <8mA <8mA <8mA <8mA
Low input signal –– ≤2.2V ≤2.2V ≤2.2V ≤2.2V
High input signal –– ≥3.4V ≥3.4V ≥3.4V ≥3.4V
Input signal delay –– ≥50ms ≥50ms ≥50ms ≥50ms
CALENDAR CLOCK
Backup reserve power –– –– Backup capacitor Backup capacitor Backup capacitor
Operation without power voltage –– –– 5 min approx. 14 days approx. 14 days approx.
RELAY OUTPUTS
Number of outputs 3 7 7 7 10
Configuration – 2NO: AC1 - 4A 250VAC; – 6NO: AC1 - 8A 250VAC; – 6NO: AC1 - 8A 250VAC; – 2NO: AC1 - 12A 250VAC; – 3NO: AC1 - 12A 250VAC;
1.5A 250V~ AC15 AC15 -1.5A 250VAC; B300 AC15 -1.5A 250VAC; B300 AC15 - 1.5A 250VAC; B300 AC15 - 1.5A 250VAC; B300
– 1NO: AC1 - 3A 250VAC; – 1 changeover: – 1 changeover: – 2NO: AC1 - 8A 250VAC; – 3NO: AC1 - 8A 250VAC;
DC1 - 3A 30VDC AC1 - 8A 250VAC, AC1 - 8A 250VAC, AC15 - 1.5A 250VAC; B300 AC15 - 1.5A 250VAC; B300
DC1 - 8A 30VDC; DC1 - 8A 30VDC; – 3 changeover: – 4 changeover:
AC15 - 1.5A 250VAC, AC15 - 1.5A 250VAC, AC1 - 8A 250VAC, AC1 - 8A 250VAC,
B300 30VDC1A B300 30VDC1A DC1 - 8A 30VDC; DC1 - 8A 30VDC;
Auxiliary service Auxiliary service AC15 - 1.5A 250VAC; AC15 - 1.5A 250VAC;
B300 30VDC 1A B300 30VDC 1A
Auxiliary service Auxiliary service
Mechanical / electrical endurance 1x107 / 1x105 operations 1x107 / 1x105 operations 1x107 / 1x105 operations 1x107 / 1x105 operations 1x107 / 1x105 operations
STATIC OUTPUT
Output type –– –– –– –– NO
Operating voltage –– –– –– –– 10-30V
Maximum current –– –– –– –– 50mA

26-16
26 Automatic transfer switch controllers
Technical characteristics

ATL 100 ATL 600 ATL 601 ATL 610 ATL 800 ATL 900
AMBIENT CONDITIONS
Operating temperature -30...+70°C
Storage temperature -30...+80°C
Relative humidity <80% (IEC/EN 60068-2-78)
Maximum pollution degree 2
Overvoltage category 3
Measurement category III
Climatic sequence Z/ABDM (IEC/EN 60068-2-61)
Shock resistance 15g (IEC/EN 60068-2-27)
Vibration resistance 0.7g (IEC/EN 60058-2-6)
HOUSING
Version Modular housing 3 modules Flush-mount
(DIN 43880)
Material Polyamide RAL 7035 Polycarbonate
IEC degree of protection IP40 on front IP40 on front IP65 on front
IP20 on terminals IP65 with optional gasket IP20 on terminals
IP20 on terminals
Weight 300g 600g 680g 1000g 1800g
CERTIFICATIONS AND COMPLIANCE
Certifications obtained EAC cULus (ATL 601 pending), RCM (only for ATL 600 - ATL 610), EAC
Compliance with standards IEC/EN 61010-1, IEC/EN 61010-1, IEC/EN 61010-2, IEC/EN 61000-6-2, IEC/EN 61000-6-4, IEC/EN 60947-1,
IEC/EN 61010-2, IEC/EN 60947-6-1, UL508 e CSA C22.2 n°14
IEC/EN 61000-6-2,
IEC/EN 61000-6-4,
IEC/EN 60947-1,
IEC/EN 60947-6-1