You are on page 1of 1

B-20, MIDC, Ambad, Nashik - 4220 10,

Maharashtra, INDIA.
Tel : +91 253 6622701/2
Fax: +91 253 6604710
Electrofusion Elbow 45° sales@kimplaspiping.net
www.kimplaspiping.net
for Gas - SDR11 (ISO S5)

0
45
d
O

H
OD

H
4.7 mm Pin Terminal
75 E75D45YEA 18 352 94 152 130 80 7
90 E90D45YEA 8 661 113 192 160 140 15
Note : SP = Standard Pack Quantity, g = Weight in Grams, F-T = Fusion Time in Seconds, C-T = Cooling Time in Minutes

Kimplas Electrofusion Elbows, manufactured in PE80 (Yellow) grade are Standard SDR 11 rated. For exact recommendations on compatibility for
welding with SDR 9 through SDR 21 pipes, refer Kimplas Technical Specifications manual.
Kimplas Electrofusion Elbows are suitable for permanently connecting PE80 pipes, both in straight as well as coil form.

Standards: Advantages :
• PE Pipe Compatibility : IS:14885, ISO:4437, EN:1555-1, GIS PL 2 /2 • Standard Operating Voltage - 40 V
• Complies with GIS PL 2 /4 • Same fusion time for various SDR rated pipes
• Higher penetration of pipe in the fittings enables proper alignment
Common Applications:
• Optimal fusion and cold zone for a strong and sturdy joint
 Make 45° Turn on mains and distribution pipes in a distribution
• Auto Temperature compensation for ambient conditions-5°C to +
network
40°C
 Turning pipe through 45° in narrow trenches, in areas difficult to
• Clearance-Fit for ease of installation
access and House Service Connections (HSC)
• Pop-Up fusion indicators to indicate fusion process performance
 Pipe Connections with spigot end fittings, pipe stub ends etc
• Permanent Batch Indicator, Fusion Time, Cooling Time, Raw
Material Grade and SDR marking
Gas/water-Rev02/April17

Installation :
• Each fitting individually packed in PE bag to protect against
Joint preparation must be done as specified in the installation contamination and oxidation
instructions. Pipe outside surface must be scraped to remove oxidised • Each fitting with water-proof bar code to automatically feed fusion
layer. Before fusing, pipe ends and inside of the fittings must be data to the Control-box for fusion process
cleaned to remove dirt and contamination. Complete Installation
Manual may be downloaded.

TM

GIS/PL-4:2014
KM 518050

For details about our other products and specifications please refer the corporate website
Disclamer : Kimplas reserve the right to modify product without prior notice, as part of its continual improvement programme. Whilst every effort is taken to
ensure the accuracy of information contained in the data Sheet, Kimplas accepts no liability for matters arising as a result of errors or omissions.