You are on page 1of 4

CE23E – BUILDING DESIGN2 LEC

 
Midterm Exam
2ND Semester AY 2019-2020
 
NAME: JELIANNE KYLA TAN PIAN                              SECTION: 5CE1                  DATE: 04-27-2020             
                                                                                                                        
               
TEST I: TRUE OR FALSE
 
1. TRUE SUBSOIL DRAIN ARE UNDERGROUN DRAIN PIPES THAT RECEIVE SUB-SURFACE OR SEEPAGE WATER ONLY
AND CONVEY IT TO A DISPOSAL.
 
2. TRUE LOCAL VENT PIPE IS A PIPE ON THE FIXRURE SIDE OF THE TRAP THROUGH WICH VAPOR OR FOUL AIR IS
REMOVED FROM A ROO OR FIXTUREE.

3. TRUE BLIND FLANGE IS A FLANGE THAT CLOSES THE END OF A PIPE. THERE IS NO OPENING FOR THE PASSAGE OF
WATER.

4. FALSE BRANCH IS THE LENGTH OF SOIL OR WASTE STACK CORRESPONDING IN GENERAL TO A STOREY HEIGHT
FROM ONE             FLOOR OR STOREY OF A BUILDING ARE CONNECTED TO THE STACK.

5. TRUE HORIZONTAL PIPE MEANS ANY PIPE OR FITTING WHICH MAKES AN ANGLE OF MORE THAN 45 DEGREES
WITH THE VERTICAL.
 
6. TRUE FLOOD LEVEL IS DEVICE LOCATED INSIDE THE TANK FOR THE PURPOSE OF MAITAINING WATER LEVEL FOR
EFFECTIVE FLUSHING OF THE WATER CLOSET.

7. FALSE FIXTURE SUPPLY IS A DRAIN FRROM THE TRAP OF A FIXTURE TO THE JUNCTION OF THT DRAIN WITH ANY
OTHER DRAIN-PIPE.
 
8. TRUE STANDPIPE IS A VERTICAL PIPE USUALLY USED FOR THE STORAGE OF WATER FREQUENTLY UNDER
PRESSURE.
 
9. TRUE RETURN BEND IS AN OPEN RETURN BEND USUALLY WITH INSIDE THREADS BUT APPLIED ALSO TO 180
DEGREES BEND IN PIPE.
 
10. FALSE MAIN EWER IS THE PRINCIPAL ARTERY OF THE VENTING SYSTEM TO WHICH VENT BRANCHES MAGY BE
CONNECTED.
11. TRUE SANITARY IS A SEWER INTENTED TO RECEIVE SANITARY SEWAGE WITH OR WITHOUT INDUSTRIAL WASTES
AND WITHOUT THE ADMIXTURE OF SURFACE WATER, STORMWATER ORDRAINAGE.

12. TRUE SIDE VENT IS VENT CONNECTING TO THE DRAIN PIPE THROUGH A FITTING AT AN ANGLE NOT GRATER
THAN45 DEGREES OR TO THE VERTICAL.

13. FALSE TRAP SEAL IS A FITTING SO DESIGNED AS TO PROVDE WHEN PROPERLY VENTED A LIQUID SEAL THAT WILL
PREVENT THE BACK PASSAGE OF AIR WITHOUT MATERILLY AFFECTING THE FLOW OF SEWAGE THROUGGH IT.
 
14. TRUE VERTICAL PIPE SYTEM IS A PIPE INSTALLED IN VERTICA POSITION OR AT AN ANGLE NOT MRE THAN 45
DEGREES WITH THE VERTICAL
 
15. TRUE RELIEF VENT ITS PRIMARY FUNCTION IS TO PROVIDE CIRCULATION OF AIR BETWEEN DRAINAGE AND VENT
SYSTEMS.

16. FALSE VERTICAL PIPE IS A PIPE THAT CONVEYS LIQUID FROM FIXTURE THAT IS FREE OF FECAL MATTER.

17. TRUE BACK FLOW IS THE FLOW OF WATER OR LIQUID MIXTURE OR SUBTANCES INTO DITRIBUTING PIPES OA
APORTABLE SUPPLY OF WATER FROM ANY SOURCE.

18. TRUE DEAD END IS THE EXTENDED PORTION OF PIE THAT IS CLOSED AT ONE END PERMITTING THE STAGNATION
OF WATER OR AIR THEREIN

19. FALSE ANY PIPE THAT CONVEYS WASTE COMING FROM WATER CLOSET IS CALLED WASTE PIPE.

20. TRUE ANY PIPE THAT CONVEYS WASTE FROM VARIOUS FIXTURE OTHER WATER CLOSET IS CALLED SOIL PIPE.

21. FALSE COPPER PIE IS ONE OF THE OLDEST PLUMBING MATERIALS USED BY EGYPTIANS, GREEKS AND ROMAN
BUILDERS AS SOIL AND WASTE PIPE.

22. FALSE LEAD PIPE IS A CAST IN LONGER LENGTH AND EASILY TO CUT AS WELL AS TO INSTALL.

23. FALSE DRY VENT IS A BRANCH OF VENT THAT SEWERS TWO OR MORE TRAPS, AND EXTENDS FROM THE FRONT
OF THE LAST FIXTURE CONNECTIONOF A HORIZONTAL BRANCH TO THE VENT STACK.
 
24 TRUE COPPER PIE IS A DURABLE AND EXTREMELY CORROSIVE RESISTANT MATEIAL AND IT IS EASILY TO INSTALL
COMPARED WITH OTHER TYPES OF PIPE.
25 TRUE BITUMINOUS FIVER SEWER PIPEIS THE CHEAPEST AMONG THE SEWER PIPES AND IT SOMETIMES
RECOMMENDED FOR HOUSE SEWER AND FOR SEPTIC TANK INSTALLATION.
  26. FALSE ANY PIPE THAT CONEYS WASTE FROM FIXTURES OTHER THAN WATER CLOSET IS CALLED WASTE PIE.
 
  27. FALSE ANY PIPE THAT CONVEYS WASTE COMING FROM WATER CLOSET IS CALLED SOIL PIPE.
 
  28.TRUE BLACK SIPHONAGE REFERS TO BACK FLOW OF USED CONTAMINATED OR POLLUTED WATER FROM A
PLUMBING FIXTURE OR VESSEL INTO A WATER SUPPLY PIPE.
  29. FALSE BLIND FLANGE CONTROLLED OULET ON A PIPELINE USED TO DISCHARGE WATER.
  30. FALSE CIRCUIT VENT IS A VERTICAL VENT THAT IS CONTINUATION OF THE DRAIN TO WHICH THE VENT CONNECTS
  31. FASE CROSS CONNECTION IS A PHYSICAL CONNECTION BETWEEN TO SEPARATE PIPING SYSTEM, ONE CONTAINS
POTABLE WATER, AND OTHER FROM UNKNOWN OR QUESTIONABLE SAFETY.
 
  32. TRUE DRAINGE SYSTEM INCLUDES ALL PIPING WITHIN THE PUBLIC  OR PRIVATE PREMISES THAT COVEYS SEWAGE,
RAINWATER, OR OTHER LIWUID WASTE, TO A LEGAL POINTS OF DISOSAL.
  33. TRUE DEVELOPED LENGTH IS THE LENGTH ALONG THE CENTER OF THE PIPE AND FITTING.
  34. TRUE VITRIFIED CLAY PIPE IS ONE OF THE OLDEST MATERIAL USED FOR SEWER LINES. IT IS MADE FROM CLAY CAST
INTO LENGTH OF 75 CM. TREATED WITH GLAZING COMPOUND.
  35 TRUE CAST IRON PIPE IS THE MOST POPULAR AND GENERALLY SPECIFIED MATERIAL FOR DRAINAGE SYSTEM IN
BUILDINGS IN THE CAST IRON PIPE.
  36._ TRUE FLLUSH VALVE IS A DEVICE LOCATED AT THE BOTTOM OF THE TANK FOR FLUSHING WATER CLOSETS AND
SIMILAR FIXTURE.
 
  37. TRUE BRANCH VENT IS A VENT CONNECTING ONE OR MORE INDIVIDUAL VENTS WITH A VENT STACK OR STACK
VENT.
38. TRUE COMMON VENT IS A DRAIN FROM TWO OR THREE FIXTURE CONNECED TO A SINGLE TRAP. IT IS ALSO CALLED
DUAL VENT.
 
  39 TRUE PLUMBING FIXTURES ARE INSTALLED RECEPTACLES, DEVICES, OR APPLIANCES WHICH ARE SUPPLIED WITH
WATER, OR WHICH RECIEVES OR DISCHARGES LIQUID OR LIQUID BORNE WASTE.
40. TRUE BRASS PIPE IS THE MOST POPULAR AND GENERALLY SPECIFIED MATERIAL FOR DRAINAGE SYSTEM IN
BUILDINGS LESS THAN 25 STOREY HIGH.
 
41 FALSE CAST IRON PIPEIS THE MOST EXPENSIVE TYPE OF PIPE AND IT IS MADE OF ALLOY OR ZINK AND COPPER AT
15 PERCENT AND 85 PERCENT PROPORTION RESPECTIVELY.
 
42 TRUE ASBESSTOS PIPE IT IS MADE OF ASBESTOS FIBERS AND PORTLAND CEMENTAND ITS PIPE THICKNESS AND IT IS
TWICE AS THAT STANDRD CAST IRON PIPEAND ALSO CAN BE USED AS SOIL WASTE, VENTILATION AND
DOWNSPOUT.
43 TRUE DEAD ENDIT IS THE EXTENDED PORTION OF A PIPE THAT IS CLOSED AT ONE END PERMITTING THE
STAGNATION OF WATER OR AIR THEREIN.
44 TRUE BACK FLOW IS THE FLOW OF WATER, OR OTHER LIQUID MIXTURE OR SUBTANCES INTO THE DISTRIBUTING
PIPES OF A PORTABLE SUPPLY OF WATER FROM ANY SOURCE.
  45. FALSE SIDE VENT ITS PRIMART FUNCTION IS TO PROVIDE CIRCULATION OF AIR BETWEEN DRAINGE AND VENT
SYSTEMS.
 
 46. FALSE RELIEF VENT IS A VENT CONNECTING TO THE DRAIN PIPE THROUGH A FITTING AT AN ANGLE NOT GREATER
THAN 45 DEGREES OR TO THE VERTICAL.
47. TRUE SANITARY SEWER IT IS A SEWER INTENDED TO RECEIVE SANITARY SEWAGE WITH OR WITHOUT INDUSTRIAL
WASTES AND WITHOUT THE ADMIXTURE OF SUFACE WATER, STORM WATEROR DRAINAGE.
48. TRUE RETURN BEND IT IS USUALLY WITH INSIDE THREADS, BUT APPLIED ALSO TO 180 DEGRESS BEND IN PIPE.
49. TRUE SATAND PIPE IS A VERTICAL PIPE USUALLY USED FOR THE STORAGE OF WATER, FREQUENTLY UNDER
PRESSURE.
50. TRUE FLOOD LEVEL IS A DEVICE LOCATED INSIDE THE TANK FOR THE PURPOSE OF MAITAINING WATER LEVEL FOR
EFFECTIVE FLUSHING OF THE WATER CLOSET.
                                                                                                          

 TEST IV: MULTIPLE CHOICES – PUT CAPITAL LETER OF THE ANSWERS ON THE LEFT SIDE

 
 

51. A IS ANOTHER KIND OF PUBLIC SEWER LINE THAT CARRIES STORM WATER AND IT
TERMINATES IN A NATURAL DRAIN SUCH AS CANALS, LAKES OR RIVERS.
52. A. STORM DRAIN B.MANHOLE                           C. FIXTURE DRAIN               D. SEWER LINE
 

52. B IS A RECEPTACLE OR VAULT USED TO CLLLECT ORGANIC WASTE


DISCHARGED FGROM THE HOUSE SEWER.

55. A IS MADE OF ASBESTOS FIBERS AND PORLAND CEMENT AND THE THICKNESS IS TWICE AS THAT
OF THE STANDARD CAST IRON
PIPE.

A. ASBESTOS PIPE B. CAST IRON PIPE               C. PLASTIC PIPE                   D. LOOPED VENT


56. A IT REFERS TO TKE BACK FLOW OF USED CONTAMINATED OR POLLUTED WATER FROM
PLUMBING FIXTURE OR VESSEL INTO A WATER SUPPLY PIPE DUE TO A NEGATIVE PRESSRE IN SUCH A
PIE.
A. BACK SIPHONAGE B. SEWER LINE                     C. SEPTIC TANK                    D. MANHOLE