PORTABLE RESISTIVE

LOAD BANKS
FOR CIVIL AND MILITARY AVIATION

www.gse-global.com
Our advantages

• Simple operation suitable for non-trained operators


• Silent operations < 65 dB (A) on 7 m
• Suitable for workshop or airside operation
• Carrying shipping case with pull up handle as standard for each load bank
• Double thermal protection
• Tilt protection - load bank work only in horizontal position
• Phase detection - load bank work only if all ABC phases are available
• Digital and Analogue models for AC – 400 Hz and DC 28.5 V DC load banks
• Fine regulation as standard for all AC – 400 Hz load banks
• Aluminum housing and non corrosive parts
• High component quality
• High reliability
• Spare parts availability and accurate on-time deliveries
• Tailor made load bank production
• Short delivery times
• 2 years warranty
• CE certification
• Requirements according DFS 400
DEKAL LOAD BANKS ∙ DEKAL AGREGATI L.T.D.
DEKAL UL. LUDVIKA PLAMBERGERJA 25
SI-2204 MIKLAVZ NA DR. POLJU ∙ SLOVENIA ∙ EUROPE

LOAD BANKS Tel.: ++386(0)2 320 325-0 ∙ Fax: ++386(0)2 320 325-2
Email: info@gse-global.com ∙ www.gse-global.com

PORTABLE RESISTIVE 400 Hz ANALOGUE LOAD BANKS


SPECIFICALLY DESIGNED RUGGED UNITS USED FOR THE TESTING AND SERVICING OF 400 Hz 115 / 200 V GPU’s

TECHNICAL SPECIFICATION ALB-45 ALB-80 ALB-100 ALB-120 ALB-140


VOLTAGE [V] 115 / 200 VAC ±10 %
FREQUENCY [Hz] 400 Hz ±10 %
LOAD / POWER [kW / kVA] (cosφ=1) 48 kW±5 % 80 kW±5 % 104 kW±5 % 120 kW±5 % 144 kW±5 %
ANALOGUE AMMETER MOV.IRON – CLASS 1.5 A
ANALOGUE VOLTMETER MOV.IRON – CLASS 1.5 V
ANALOGUE FREQUENCY METER MOV.COIL – CLASS 0.5 Hz
LOAD raising within 30 sec. from 0 to 100% LOAD,
LOAD TEST PROPOSAL HOLD on 100% LOAD for 5 min
FOR GPU TESTING LOAD decreasing within 10 min from 100 to 0% LOAD

LOAD TEST PROPOSAL LOAD raising within 30 sec. from 0 to 100% LOAD,
FOR ENGINE DECARBONISING HOLD on 100% LOAD for 45 min
LOAD decreasing within 15 min from 100 to 0% LOAD
COOLING–FORCED [m³/min] 44,10 66,15 88,20 88,20 88,20

NORMS
STANDARDS ISO 6858, DSF 400, ARP 5015
CLASIFICATION CE marking, DIN, VDE, IEC

ENVIRONMENT
OPERATING TEMPERATURE -10 do + 55 ºC
MAXIMUM ALTITUDE 1000 m (WITHOUT DOWNGRADING), max 2000 m
RELATIVE HUMIDITY 0% - 85% (W.O.CONDENSATION)
NOISE LEVEL <70
DEGREE OF PROTECTION IP 21
DIMENSIONS [ L x B x H mm] / 600 x 230 x 630 600 x 230 x 630 600 x 230 x 630 600 x 230 x 630 600 x 230 x 630
WEIGHT [kg] 25 27 30 33 35
PAINTING POWDER COATING FINE STRUCTURE 71319 IGP / Swiss quality
Including carrying & shipping case per unit / All specifications are subject to change without notice
DEKAL
DEKAL LOAD BANKS ∙ DEKAL AGREGATI L.T.D.
UL. LUDVIKA PLAMBERGERJA 25
SI-2204 MIKLAVZ NA DR. POLJU ∙ SLOVENIA ∙ EUROPE

LOAD BANKS Tel.: ++386(0)2 320 325-0 ∙ Fax: ++386(0)2 320 325-2
Email: info@gse-global.com ∙ www.gse-global.com

PORTABLE RESISTIVE 400 Hz DIGITAL LOAD BANKS – USB CONNECTED


SPECIFICALLY DESIGNED RUGGED UNITS USED FOR THE TESTING AND SERVICING OF 400 Hz 115 / 200 V GPU’s

TECHNICAL SPECIFICATION ALB-45D ALB-80D ALB-100D ALB-120D ALB-140D


VOLTAGE [V] 115 / 200 VAC ±10 %
FREQUENCY [Hz] 400 Hz ±10 %
LOAD / POWER [kW / kVA] (cosφ=1) 48 kW±5 % 80 kW±5 % 104 kW±5 % 120 kW±5 % 144 kW±5 %
3 LINE HIGH BRIGHTNESS RED LED DISPLAY V / A / Hz /
CLASS: ±0.5% S ACC. IEC 62053-22:2003 cosφ / kW / kVA
CONNECTION TO PC ( USB CABLE & SOFTWARE INCL.) USB
LOAD raising within 30 sec. from 0 to 100% LOAD,
LOAD TEST PROPOSAL HOLD on 100% LOAD for 5 min
FOR GPU TESTING LOAD decreasing within 10 min from 100 to 0% LOAD

LOAD TEST PROPOSAL LOAD raising within 30 sec. from 0 to 100% LOAD,
FOR ENGINE DECARBONISING HOLD on 100% LOAD for 45 min
LOAD decreasing within 15 min from 100 to 0% LOAD
COOLING–FORCED [m³/min] 44,10 66,15 88,20 88,20 88,20

NORMS
STANDARDS ISO 6858, DSF 400, ARP 5015
CLASIFICATION CE marking, DIN, VDE, IEC

ENVIRONMENT
OPERATING TEMPERATURE -10 do + 55 ºC
MAXIMUM ALTITUDE 1000 m (WITHOUT DOWNGRADING), max 2000 m
RELATIVE HUMIDITY 0% - 85% (W.O.CONDENSATION)
NOISE LEVEL <70
DEGREE OF PROTECTION IP 21
DIMENSIONS [ L x B x H mm] / 600 x 230 x 630 600 x 230 x 630 600 x 230 x 630 600 x 230 x 630 600 x 230 x 630
WEIGHT [kg] 26 28 31 34 36
PAINTING POWDER COATING FINE STRUCTURE 71319 IGP / Swiss quality
Including carrying & shipping case per unit / All specifications are subject to change without notice
DEKAL LOAD BANKS ∙ DEKAL AGREGATI L.T.D.
DEKAL UL. LUDVIKA PLAMBERGERJA 25
SI-2204 MIKLAVZ NA DR. POLJU ∙ SLOVENIA ∙ EUROPE

LOAD BANKS Tel.: ++386(0)2 320 325-0 ∙ Fax: ++386(0)2 320 325-2
Email: info@gse-global.com ∙ www.gse-global.com

PORTABLE RESISTIVE 400 Hz DIGITAL LOAD BANKS – LAN & WiFi CONNECTED
SPECIFICALLY DESIGNED RUGGED UNITS USED FOR THE TESTING AND SERVICING OF 400 Hz 115 / 200 V GPU’s

TECHNICAL SPECIFICATION ALB-45DW ALB-80DW ALB-100DW ALB-120DW ALB-140DW


VOLTAGE [V] 115 / 200 VAC ±10 %
FREQUENCY [Hz] 400 Hz ±10 %
LOAD / POWER [kW / kVA] (cosφ=1) 48 kW±5 % 80 kW±5 % 104 kW±5 % 120 kW±5 % 144 kW±5 %
3 LINE HIGH BRIGHTNESS RED LED DISPLAY V / A / Hz /
CLASS: ±0.5% S ACC. IEC 62053-22:2003 cosφ / kW / kVA
CONNECTION TO PC (LAN CABLE & SOFTWARE INCL.) LAN and WiFi
LOAD raising within 30 sec. from 0 to 100% LOAD,
LOAD TEST PROPOSAL HOLD on 100% LOAD for 5 min
FOR GPU TESTING LOAD decreasing within 10 min from 100 to 0% LOAD

LOAD TEST PROPOSAL LOAD raising within 30 sec. from 0 to 100% LOAD,
FOR ENGINE DECARBONISING HOLD on 100% LOAD for 45 min
LOAD decreasing within 15 min from 100 to 0% LOAD
COOLING–FORCED [m³/min] 44,10 66,15 88,20 88,20 88,20

NORMS
STANDARDS ISO 6858, DSF 400, ARP 5015
CLASIFICATION CE marking, DIN, VDE, IEC

ENVIRONMENT
OPERATING TEMPERATURE -10 do + 55 ºC
MAXIMUM ALTITUDE 1000 m (WITHOUT DOWNGRADING), max 2000 m
RELATIVE HUMIDITY 0% - 85% (W.O.CONDENSATION)
NOISE LEVEL <70
DEGREE OF PROTECTION IP 21
DIMENSIONS [ L x B x H mm] / 600 x 230 x 630 600 x 230 x 630 600 x 230 x 630 600 x 230 x 630 600 x 230 x 630
WEIGHT [kg] 26 28 31 34 36
PAINTING POWDER COATING FINE STRUCTURE 71319 IGP / Swiss quality
Including carrying & shipping case per unit / All specifications are subject to change without notice
DEKAL LOAD BANKS ∙ DEKAL AGREGATI L.T.D.
DEKAL UL. LUDVIKA PLAMBERGERJA 25
SI-2204 MIKLAVZ NA DR. POLJU ∙ SLOVENIA ∙ EUROPE

LOAD BANKS Tel.: ++386(0)2 320 325-0 ∙ Fax: ++386(0)2 320 325-2
Email: info@gse-global.com ∙ www.gse-global.com

PORTABLE RESISTIVE 28,5 V DC ANALOGUE LOAD BANKS


SPECIFICALLY DESIGNED RUGGED UNITS USED FOR THE TESTING AND SERVICING OF 28,5 V DC GPU’s.

TECHNICAL SPECIFICATION DLB-03 DLB-ESS-15 DLB-ESS-20 DLB-ESS-25


VOLTAGE [V] 28,5 V DC ±20 %
LOAD [A] 300 A±20 % 1500 A±20 % 2000 A±20 % 2500 A±20 %
ANALOGUE AMMETER MOV.COIL – CLASS 1.5 A
ANALOGUE VOLTMETER MOV.COIL – CLASS 1.5 V
300 A – 20 minutes
300 A – 20 minutes 300 A – 20 minutes
or
or or
Load Test in 5 steps
600 A - 20 minutes 600 A - 20 minutes
LOAD STEPS 20 minutes 1400 A - 0 A (35 sec.)
or or
or
Load Test in 6 steps Load Test in 6 steps
Load Test in 6 steps
1500 A - 0 A (35 sec.) 2000 A - 0 A (35 sec.)
2500 A - 0 A (35 sec.)
20 min. at 100 % ESS - Engine ESS - Engine ESS - Engine
LOAD TEST PROCEDURE
LOAD Start Simulation Start Simulation Start Simulation
COOLING–FORCED [m³/min] 22,05 44,10 44,10 44,10

NORMS
STANDARDS ISO 6858, DSF 400, ARP 5015
CLASIFICATION CE marking, DIN, VDE, IEC

ENVIRONMENT
OPERATING TEMPERATURE -10 do + 55 ºC
MAXIMUM ALTITUDE 1000 m (WITHOUT DOWNGRADING), max 2000 m
RELATIVE HUMIDITY 0% - 85% (W.O.CONDENSATION)
NOISE LEVEL <70
DEGREE OF PROTECTION IP 21
DIMENSIONS [ L x B x H mm] / 570 x 230 x 450 570 x 230 x 450 570 x 230 x 450 570 x 230 x 450
WEIGHT [kg] 18 20 25 26
PAINTING POWDER COATING FINE STRUCTURE 71319 IGP / Swiss quality
Including carrying & shipping case per unit / All specifications are subject to change without notice
DEKAL
DEKAL LOAD BANKS ∙ DEKAL AGREGATI L.T.D.
UL. LUDVIKA PLAMBERGERJA 25
SI-2204 MIKLAVZ NA DR. POLJU ∙ SLOVENIA ∙ EUROPE

LOAD BANKS Tel.: ++386(0)2 320 325-0 ∙ Fax: ++386(0)2 320 325-2
Email: info@gse-global.com ∙ www.gse-global.com

PORTABLE RESISTIVE 28,5 V DC DIGITAL LOAD BANKS


SPECIFICALLY DESIGNED RUGGED UNITS USED FOR THE TESTING AND SERVICING OF 28,5 V DC GPU’s.

TECHNICAL SPECIFICATION DLB-03D DLB-ESS-15D DLB-ESS-20D DLB-ESS-25D


VOLTAGE [V] 28,5 V DC ±20 %
LOAD [A] 300 A±20 % 1500 A±20 % 2000 A±20 % 2500 A±20 %
3 LINE HIGH BRIGHTNESS RED LED DISPLAY
V / A / kW
CLASS: ±0.5% FS+2C
300 A – 20 minutes
300 A – 20 minutes 300 A – 20 minutes
or
or or
Load Test in 5 steps
600 A - 20 minutes 600 A - 20 minutes
LOAD STEPS 20 minutes 1400 A - 0 A (35 sec.)
or or
or
Load Test in 6 steps Load Test in 6 steps
Load Test in 6 steps
1500 A - 0 A (35 sec.) 2000 A - 0 A (35 sec.)
2500 A - 0 A (35 sec.)
20 min. at 100 % ESS - Engine ESS - Engine ESS - Engine
LOAD TEST PROCEDURE
LOAD Start Simulation Start Simulation Start Simulation
COOLING–FORCED [m³/min] 22,05 44,10 44,10 44,10

NORMS
STANDARDS ISO 6858, DSF 400, ARP 5015
CLASIFICATION CE marking, DIN, VDE, IEC

ENVIRONMENT
OPERATING TEMPERATURE -10 do + 55 ºC
MAXIMUM ALTITUDE 1000 m (WITHOUT DOWNGRADING), max 2000 m
RELATIVE HUMIDITY 0% - 85% (W.O.CONDENSATION)
NOISE LEVEL <70
DEGREE OF PROTECTION IP 21
DIMENSIONS [ L x B x H mm] / 570 x 230 x 450 570 x 230 x 450 570 x 230 x 450 570 x 230 x 450
WEIGHT [kg] 18 20 25 26
PAINTING POWDER COATING FINE STRUCTURE 71319 IGP / Swiss quality
Including carrying & shipping case per unit / All specifications are subject to change without notice
DEKAL
DEKAL LOAD BANKS ∙ DEKAL AGREGATI L.T.D.
UL. LUDVIKA PLAMBERGERJA 25
SI-2204 MIKLAVZ NA DR. POLJU ∙ SLOVENIA ∙ EUROPE

LOAD BANKS Tel.: ++386(0)2 320 325-0 ∙ Fax: ++386(0)2 320 325-2
Email: info@gse-global.com ∙ www.gse-global.com

CABLE / PLUG TEST BOX CABLE / PLUG PIN TESTER


SPECIFICALLY DESIGNED RUGGED UNITS USED FOR THE TESTING AND PIN TESTER IS USED FOR TESTING INSERTION AND RETRACTION FORCES OF
SERVICING 115/200 V 400 HZ POWER CABLES & AIRCRAFT PLUGS. AIRCRAFT CABLE PLUGS TO ENSURE POSITIVE, SAFE CONNECTION.

TECHNICAL SPECIFICATION CPT-400 TECHNICAL SPECIFICATION PTG-D


VOLTAGE [V] 115 / 200 V AC ±10 % Rechargeable batteries / Charger
POWER
(100 – 240 V AC)
FREQUENCY [Hz] 400 Hz±10 %
DATA INTERFACE RS 232 + Software
28 V Trafo, Power indicator lights,
Phase rotation indication, UNITS N / kg / lb
INDICATION
E&F circuit indication, Plug test pins for connect- INDICATION ERROR ± 5%
ing external measurment device
PEAK LOAD VALUE 100 N 10 kg 22 lb
NORMS LOAD DIVISION VALUE 0,1 N 0,01 kg 0,01 lb
STANDARDS ISO 6858, DSF 400, ARP 5015
NORMS
CLASIFICATION CE marking, DIN, VDE, IEC
STANDARDS ISO 6858, DSF 400, ARP 5015
ENVIRONMENT CLASIFICATION CE marking, DIN, VDE, IEC
OPERATING TEMPERATURE -10 do + 40 ºC
ENVIRONMENT
MAXIMUM ALTITUDE 1000 m (WITHOUT DOWNGRADING), max 2000 m
OPERATING TEMPERATURE 5 ºC ~ 35 ºC
RELATIVE HUMIDITY 0% - 85% (W.O.CONDENSATION)
RELATIVE HUMIDITY 15% - 80%
DEGREE OF PROTECTION IP 21
WORKING CONDITIONS NO HYPOCENTER AND CORROSIVE MEDIUM
DIMENSIONS [ L x B x H mm] / 300 x 160 x 170
WEIGHT [kg] 11 DIMENSIONS [ L x B x H mm] / 230 x 66 x 36
WEIGHT [kg] 0,45
PAINTING RAL 1018
All specifications are subject to change without notice
PAINTING RAL 9005 or RAL 9001
All specifications are subject to change without notice
400 HZ DIGITAL USB LOAD BANK 400 HZ ANALOGUE LOAD BANK 400 HZ DIGITAL LAN / WiFi LOAD BANK Our product range

CABLE / PLUG TEST BOX, PIN TESTER 28,5 V DC ANALOGUE LOAD BANK 28,5 V DC DIGITAL USB LOAD BANK
DEKAL LOAD BANKS
DEKAL AGREGATI D.O.O. (LTD)
Ulica Ludvika Plambergerja 25
SI-2204 Miklavz na Dravsem polju
SLOVENIA – EUROPE

++ 386 2 320 325 0


++ 386 2 320 325 2