TEST RAY'S INSPECTION AND ENGINEERING SERVICES

SF.No. 413/3B,MOPPERIPALAYAM(POST),, COIMBATORE., Pincode :641 659.


Phone :0421 - 3269845,96009 44001,02,03, Mail :tiesndt@gmail.com , CST No. :1028619 Dt.01.09.2009

RADIOGRAPHIC EXAMINATION REPORT

M/s. : SCHUTTE MEYER ASHWATH ALLOYS PVT LTD Page 1 of 1

Customer : L&T VALVES LIMITED Report No Page 1 of


: TIES/SMA/2798 - A1

Description : 24" 150 BONNET Report Date : :20/01/2017


Drawing No : LT3B2095R REV0 Radiography No : SMT173

Grade : WCC Heat No : B5953

Ir-192 Source Strength :35Ci Source Size :2.7MMDIAX3.5HTHT


Date of Test : 17/01/2017
Co-60 Source Strength :40Ci Source Size :3.2MMDIAX2.5HT
Film Type : KODAK AA400 Evaluation Reference : E446/E186

Pb Screen Thickness : 0.1MM BACK 0.15MM Procedure Reference : NDE 001 REV 11
Shooting Technique/IQI : SWSI/ASTM Acceptance Standard : ASME B 16.34 APPENDIX-1
Technique Sheet No : DBBV-35 REV.1 Area of Coverage : 100% AREA
Sl. Location Source Thickness SFD IQI Density Film Size Findings * Classi Remarks
No (mm) (Inch) Designation Sensitivity Inchs fication

1 *1-2 Co - 60 43/72 24 35/45F 2-2T 3.8 12 X 9 B 1 Acceptable


2 *2-3 Co - 60 43/72 24 35/45F 2-2T 3.6 12 X 9 B 1 Acceptable
3 *3-4 Co - 60 43/72 24 35/45F 2-2T 3.6 12 X 9 B 1 Acceptable
4 *4-5 Co - 60 43/72 24 35/45F 2-2T 3.8 12 X 9 B 1 Acceptable
5 *5-6 Co - 60 43/72 24 35/45F 2-2T 3.2 12 X 9 NSD - Acceptable
6 *6-7 Co - 60 43/72 24 35/45F 2-2T 3.6 12 X 9 B 1 Acceptable
7 *7-8 Co - 60 43/72 24 35/45F 2-2T 3.8 12 X 9 B 1 Acceptable
8 *8-9 Co - 60 43/72 24 35/45F 2-2T 3.6 12 X 9 B 1 Acceptable
9 *9-1 Co - 60 43/72 24 35/45F 2-2T 3.6 12 X 9 B 1 Acceptable
10 10-11 Co - 60 95 30 60 2-2T 2.9 8X8 B 1 Acceptable
11 11-12 Co - 60 95 30 60 2-2T 2.9 8X8 B 1 Acceptable
12 12-13 Co - 60 95 30 60 2-2T 2.9 8X8 B 1 Acceptable
13 13-14 Co - 60 95 30 60 2-2T 2.9 8X8 B 1 Acceptable
14 14-15 Co - 60 95 30 60 2-2T 3.2 8X8 B 1 Acceptable
15 15-16 Co - 60 95 30 60 2-2T 2.6 8X8 NSD - Acceptable
16 16-10 Co - 60 95 30 60 2-2T 2.9 8X8 B 1 Acceptable

Total Area ( Co 60 ) 2392 Sq.Inchs Total No of Film ( Co 60 ) 16

CASTINGS ACCEPTED UNDER LEVEL 1 * DOUBLE FILMS WERE USED


*
A : Gas Hole ; B : Inclusion ; CA,CB,CC,CD : Shrinkage ; D : Crack ; E : Hot Tear ; F : Insert ; NSD : No Significant Defect ;

For TEST RAY'S INSPECTION AND


ENGINEERING SERVICES

A.CHELLA PACKIARAJ
LEVEL-II RT SUPPLIER CUSTOMER EXTERNAL INSPECTOR