You are on page 1of 2

1.

1 Design of Reinforced Wall Footing with accordance to ACI 318

LOADINGS:
DL 292.00 Kn/m
LL 220.00 Kn/m

PARAMETERS:
Allowable Soil Pressure : 190.00 Kpa
fy: 276.50 Mpa
fc'= 27.60 Mpa
ɣ soil 15700.00 N/m³
Thickness of Wall (tw) 300.00 mm
Location of Footing bottom below NGL (H): 1.20 m

ASSUMPTIONS:
ɣ concrete ( ɣc) 23.54 Kn/m²
Concrete Cover ( cc ) : 70.00 mm
Depth of Footing(D) : 450.00 mm
Size of Rebar: 16.00 mmØ

ANALYSIS:
d = D- cc - r/2 = 372.00 mm
t = 1.5tw = 450.00 mm
Wt of Footing : t * ɣc = 10.59 Kpa
Wt of soil : (H-t) * ɣsoil = 11.78 Kpa
Effective Soil Pressure = 167.63 Kpa

Area Required: = 3.05 m²


Assumed Strip = 1.00 m
L= = 3.05 m

Check for Shear Failue:


Qu=(1.4L+1.7LL)/A = 256.29 Kpa
Vu = Qu * effective Area = 257.62 Kn
Vn = Vu / ɸbd = 0.81 Mpa
Va= 1/6 *√(f'c) = 0.88 Mpa

since: Va= 0.88 greater than 0.81 footing is safe!

Check for Bending Failue:

Mu = Qu*L*(meter strip *x)*(x/2) 243.04 Kn.m


0.07
a 0.59
b -1.00
c 0.07
b^2 1.00
4ac 0.17
2a 1.18
(-) b 1.00
1.6210
0.0739
w 0.0739
Ƿactual = w * (fc' / fy) 0.0074
Ƿmin=1.4/fy 0.0051
since: Ƿmin 0.0051 less than 0.0074
use : 0.0074

As = Ƿ*b*d 2745.15 mm²


use: 16.00 mm diameter bar
Spacing: 73.24 mm O.C.

PREPARED BY : JCB

You might also like