You are on page 1of 1

Discharge Piping Over Pressure Protection

Sl. No. Description Unit Parameters Remarks


1 Rated Flow USGPM 7700
2 Rated Differential Head ft 551
3 Design Tempature °F 176
4 Maximum specific Gravity 0.8
(dmax)
5 Tank design pressure PSIg 0
6 Tank static head @HLL ft 42.3
7 Maximum suction pressure PSIg 14.7 Suction vessel design pressure (or RV set pressure) +
Vessel static head taken @ HLL [As per BMPS-A3, Clause
No. 7.1]
8 Design Pressure at the PSIg 14.7
suction of the pump (Pds)
9 K (margin factor) 1.3
10 Maximum Differential Head at PSIg 238.5 K x Net differential pressure @ rated capacity
rated Point (Hr)
11 Design Pressure at the PSIg 253.2 Maximum differential pressure + Maximum suction Pressure
discharge of the pump (Pdd) [As per BMPS-A3, Clause No. 7.1]

FLOWSERVE RUHRPUMPEN
12 Pump shut-off head ft 714.16 695.80 » Based on FLOWSERVE online Affinity software (Curve
No.EC-1728), this model is having lowest head (Shut-off
head) rise from rated head which is 29.3% and efficiency of
pump is 73%
» Based on RUHRPUMPEN online software (Curve No.VTP-
30D-1440-1180), this model is having lowest head (Shut-off
head) rise from rated head which is 25.64% and efficiency
of pump is 67%.
13 Pump shut-off pressure PSIg 247.33 240.97
14 Maximum Pump Discharge PSIg 262.04 255.68 maximum suction pressure + the pump shut-off head [As
Pressure per BMPS-A3, Clause No. 7.1]
15 MAWP of Gasoline Pipe Line PSIg 250.0
(Sea Lines)
Conclusion: Based on online available pump model, maximum pump discharge pressure is exceeding the MAWP of gasoline pipe line.
Hence, we shall install a full flow relief valve in the discharge header.

Page 1 of 1