NFPA 70E 2018 Changes


The NFPA 70E gets updated every three years. See what’s new in 2018.

 LEARN ABOUT ARC FLASH LABELING REQUIREMENTS

Home / Arc Flash Labeling Requirements / NFPA 70E Changes

Overview
The 2018 update includes some of the following changes:

• Continued emphasis on training • A greater focus on hazard elimination.

• Distinctions between employer and • Required job safety plan documentation


employee responsibilities with risk assessments

Training Requirements
Retraining should still occur every 3 years, and the 2018 update indicates that
employees must also be retrained if their job duties change, or when procedures are not
being followed (as observed by annual inspections or supervision).

Training should include:


• Specific
hazards
associated
with
electrical
energy

• Special
precautionary
techniques
and
safety
related
work
practices

• PPE,
insulating
and
shielding
materials,
insulated
tools
and
test
equipment

https://www.bradyid.com/applications/arc-flash-labeling-requirements/nfpa-70e-changes 2/26/2019
NFPA 70E 2018 Changes | Arc Flash Requirements | BRADY Page 2 of 4
• Emergency
response
and
AED
training

• Skills
and
techniques
to
distinguish
energized
parts
determine
nominal
voltages

• Approach
distances

• Decision
making
process
and
ability
to
perform
job
tasks

Training sessions must be documented and verified at least annually, and participants
must be able to demonstrate knowledge. To help keep your workplace safe and
compliant, Brady Safety offers a custom approach to Arc Flash Training.

Employer vs. Employee Responsibilities


Previously, NFPA 70E just addressed the employer when it came to safety-related work
practices. Now this section is subdivided as follows:

Employer: Employee:
Establish, document and provide Must comply with safety related
training work practices and procedures
provided by the employer

Equipment Labeling
Old Label Versions. The recent update allows labels
applied prior to the effective date of this edition of the
standard to be acceptable if they complied with the
requirements for equipment labeling in the standard in
effect at the time the labels were applied (unless changes
in electrical distribution system render the label
inaccurate). See the Seven Elements of an Arc Flash
Label.

Document and Review. Document the method of


calculating and the data to support the information for
the label and review for accuracy at intervals not to
https://www.bradyid.com/applications/arc-flash-labeling-requirements/nfpa-70e-changes 2/26/2019
NFPA 70E 2018 Changes | Arc Flash Requirements | BRADY Page 3 of 4

Establishing an Electrically Safe Work Condition


Exception for “Simple Procedures”: When it comes to equipment that is cord- or plug-connect –
for which exposure to the hazards of unexpected energization is controlled by the unplugging
of the equipment from the energy source, and the employee performing maintenance is under
exclusive control of the plug – lockout tagout is not required.

The 2018 update also added two additional steps to the process for establishing and verifying
electrically safe work conditions:

• Release stored • Release or block


electrical stored mechanical
energy energy

SHOP BRADY’S LOCKOUT TAGOUT DEVICES

Work Involving Electrical Hazards


Shock Risk Assessment was modified to require documentation and more information
regarding additional protective measures.

Arc Flash Risk Assessment was modified to identify hazards, estimate the likelihood of
occurrence and if additional protective measures are required.

Two methods for conducting an assessment:

• Incident Energy Analysis • Arc Flash PPE Category


Method Method

A Brady Safety electrical engineer can complete your assessment, provide you with a
detailed assessment report and install the correct arc flash labels.

LEARN ABOUT BRADY SAFETY’S ARC FLASH RISK ASSESSMENT SERVICES

Product Recommendations
Need to post arc flash labels on your electrical equipment? Here are our top recommended
products to get you started.

BRADYPRINTER™ BRADYPRINTER™ BRADY SAFETY AND PRE-PRINTED ARC


S3100 SIGN AND S3000 SIGN AND FACILITY FLASH LABELS &
LABEL PRINTER LABEL PRINTER IDENTIFICATION WRITE-ON LABELS
SUITE

Resources

https://www.bradyid.com/applications/arc-flash-labeling-requirements/nfpa-70e-changes 2/26/2019
NFPA 70E 2018 Changes | Arc Flash Requirements | BRADY Page 4 of 4

BRADY SAFETY ARC FLASH ARC FLASH 2018


ARC FLASH WORKPLACE UPDATE
SERVICES SAFETY GUIDE OVERVIEW

LEARN MORE DOWNLOAD LEARN MORE

Solutions Services Help Resources


Floor Marking Guide Lockout Tagout Services Contact Us Find a Distributor
GHS Label Compliance Arc Flash Services Website Feedback Design Custom Safety Signs
Lockout Tagout Compliance Confined Space Services Knowledge Center Create Custom THT Labels
Arc Flash Labeling Requirements Software Programming & Integration Printer Drivers & Firmware Printer Selection Tool
Cable and Wire Label Options Label Template & File Conversion Brady Software Updates Label Selection Tool
Product and Barcode Labeling Printer Use & Training Safety Data Sheets Digital Catalog
Printer Preventative Maintenance Technical Data Sheets Request a Catalog
Toll and Custom Coating WEEE-RoHS Compliance Interactive Facility Map
Authentication & Tracking Services Product Certification EPA e-Manifest Update
Printer Registration

Corporate Other Brady Sites Contact

About Distributor Portal 6555 W. Good Hope Rd.

Careers International Sites Milwaukee, WI 53223

Investors Safety Services & Software Phone: 888-250-3082

Privacy Policy Brand Protection Solutions Hours: 7am-6pm CT


Monday - Thursday;
Terms and Conditions
Friday 7am-5pm CT
Terms of Use
ISO Certificates

Brady (NYSE:BRC) is a manufacturer of complete solutions that identify and protect people, products and
places. Brady’s products help customers increase safety, security, productivity and performance and include
high-performance labels, signs, safety devices, printing systems and software.