1、试验目的
当凝汽器只有半面运行时,机组能在 50%负荷下正常运行。
1. test purpose
when half of condenser quit, the unit can operation on 50%
load。
2、test procedure
2.1 reduced the load under 6 mw;
2.2 close the air valve of condenser quit-side;
2.3 close the circulating water inlet valve and outlet
valve of condenser quit-side;
2.4 check the condenser vacuum and exhaust temperature
is normal, keep half of condenser running for 20min,
records of the operation parameters of turbine;
2.5 after the test, reopened the air valve、circulating
water inlet valve and outlet valve of condenser quit-
side; 2.6 raise the unit load to normal.