You are on page 1of 2

凝汽器半面运行试验

Test for half of condenser operation

1、试验目的
当凝汽器只有半面运行时,机组能在 50%负荷下正常运行。
1. test purpose
when half of condenser quit, the unit can operation on 50%
load。

2、试验步骤 test procedure


2.1 将机组负荷减至 6MW 以下;
2.2 关闭凝汽器解列侧抽空气门;
2.3 关闭凝汽器解列侧循环水的进、出水门;
2.4 检查确认凝汽器的真空及排汽温度正常,保持半面运行
20min,记录汽轮机有关运行参数;
2.5 试验结束后,重新开启凝汽器解列侧进、出水门和凝汽器汽
侧空气门;
2.6 调整机组负荷至正常值。

2、test procedure
2.1 reduced the load under 6 mw;
2.2 close the air valve of condenser quit-side;
2.3 close the circulating water inlet valve and outlet
valve of condenser quit-side;
2.4 check the condenser vacuum and exhaust temperature
is normal, keep half of condenser running for 20min,
records of the operation parameters of turbine;
2.5 after the test, reopened the air valve、circulating
water inlet valve and outlet valve of condenser quit-
side; 2.6 raise the unit load to normal.

3、记录表格 record table


运行参数 试验前 试验后
NO. Unit
parameter before test after test
1 负荷 load MW
2 真空 vacuum KPa
排汽温度
3 exhaust ℃
temperature
4 循环水进水温 ℃

circulating
water inlet
temperature
循环水出水温

5 circulating ℃
water outlet
temperature
1#轴承温度
6 1# bearing ℃
temperature
2#轴承温度
7 2# bearing ℃
temperature
3#轴承温度
8 3# bearing ℃
temperature
4#轴承温度
9 4# bearing ℃
temperature
1#轴承振动
10 1# bearing μm
vibration
2#轴承振动
11 2# bearing μm
vibration
3#轴承振动
12 3# bearing μm
vibration
4#轴承振动
13 4# bearing μm
vibration