(Unit - T, TM)
Dead Load Live Load Total Member
Member Axial B.MZ BMY Shear Axial L/C B.MZ BMY L/C Shear L/C Axial B.MZ BMY Shear No.
Bottom
Chord -175.46 837 15.20 885
-13.29 2 -5.32 2 0.00
(3 to 8,61 to
66) -351.73 4.55 -175.46 9.88 0.00 -527.19 14.43 0.00
-102.72 779 39.19 859
(1, 2, 9,
15.52 2 23.50 2
10,59, 60, 67,
68) -154.36 -20.53 -102.72 67.25 -257.08 46.72 0.00
Intermediate
Diagonal -133.12 263
-7.23 2
(Tension
member) -244.12 -140.35 0.00 0.00 -384.47 0.00 0.00
108.87 845
5.50 2
(Compressio
n member)
Dead Load Live Load Total Member
Member Axial B.MZ BMY Shear Axial L/C B.MZ BMY L/C Shear L/C Axial B.MZ BMY Shear No.
(Compressio
n member) 178.94 108.87 0.00 0.00 287.81 0.00 0.00
15.27 128.23 17.18 4.89 188.40 815 6.64 815 20.16 316.63 23.82
Cross Girder
Stringer 9.74 5.54 33.01 820 27.15 770 0.00 42.75 32.69
under Deck
5.51 27.44 808 0.00 0.00 32.95
Stringer
under
Footpath 1.26 0.8 0.80 2 0.50 2 0.00 2.06 1.30
Footpath
Girder 0 4.241 4.13 0.00 2.09 2 2.11 2 0.00 6.33 6.24
Dead Load Live Load Total Member
Member Axial B.MZ BMY Shear Axial L/C B.MZ BMY L/C Shear L/C Axial B.MZ BMY Shear No.
2.74 830
Top Diagonal
Bracing 0.18 2
6.25 1003
5.62 9.17 14.79 0.00 0.00
fcd = (fy/gm0)/(f+[f2-l2].5)
144.65 Mpa
PR = 2805052.8 N 280.505 T
Total resistance = 561.01 T
DESIGN OF LAUNCHING TRUSS FOR CHAMPA ROB
Design of Connections
For Bolt used HSFG Bolt Grade 8.8
Bolt Size M 20 Bolt pitch 75 mm
Area 226 mm^2 Edge dist. 75 mm
Capacity of one bolt in single shear = 0.577x226x640/1.25 = 66765.82 N
= 6.81 T
Bearing Strength of bolt = Vbf <= Vnbf / gmf , Vnbf = 2.2d.t.fup < 3d.t.fyp
Grade of steel used = E250 (Fe 410W)
fup = 410 MPa fyp = 250 MPa
Vnbf = Min(2.2x24xtx410 , 3x24xtx250)
Bearing Strength of bolt = Vbf <= Vnbf / gmf , Vnbf = 2.2d.t.fup < 3d.t.fyp
Grade of steel used = E250 (Fe 410W)
fup = 410 MPa fyp = 250 MPa
Vnbf = Min(2.2x24xtx410 , 3x24xtx250)
Member Force
U"0 - U'0
Member size = MC 300 [STAAD File ..... Stage 6]
Force = 43.11 T Compression
Factored force = 64.67 T
Gusset thickness = 25 mm
Bolt size = 20 mm
Bolt value = 6.81 T No. of Bolts required 10
PR = 1300090 N 130.009 T
Total resistance = 260.018 T > 64.665 T, O.K.
Gusset thickness = 10 mm
Bolt size = 20 mm
Bolt value = 6.81 T
Member Force
U"0 - U'0
Member size = MC 300 [STAAD File ..... Stage 6]
Force = 43.11 T Compression Same member continues
Factored force = 64.67 T Provide 10 nos. Bolts
U'0 - U'1
Member size = MC 300
Force = 85.08 T Compression [STAAD File ..... Stage 6]
Factored force = 127.62 T `
U'0 - L'0
Member size = MC 300
Force = 1.67 T Compression [STAAD File ..... Stage 6]
Factored force = 2.51 T
Bolt value = 6.81 T No. of Bolts required 2
Gusset thickness = 16 mm
Bolt size = 20 mm
Bolt value = 6.81 T
U'0 - U'1
Member size = MC 300
Force = 50.29 T Compression [STAAD file ...... Stage 6]
Factored force = 75.44 T
Bolt value = 6.81 T No. of Bolts required 12
U'1 - U'2
Member size = MC 300
Force = 33.20 T Compression [STAAD file ...... Stage 6]
Factored force = 49.80 T
Bolt value = 6.81 T No. of Bolts required 8
U'1 - L'0
Member size = MC 300
Force = -62.90 T Tension [STAAD file ...... Stage 6]
Factored force = -94.35 T
Bolt value = 6.81 T No. of Bolts required 14
U'1 - L'1
Member size = MC 300
Force = 61.71 T Compression [STAAD file ...... Stage 6]
Factored force = 92.57 T
Bolt value = 6.81 T No. of Bolts required 14
Gusset thickness = 16 mm
Bolt size = 20 mm
Bolt value = 6.81 T
U'1 - U'2
Member size = MC 300
Force = 11.86 T Compression [STAAD file ...... Stage 4]
Factored force = 17.79 T
Bolt value = 6.81 T No. of Bolts required 4
U'2 - U'3
Member size = MC 200
Force = 15.64 T Compression [STAAD file ...... Stage 10]
Factored force = 23.46 T
Bolt value = 6.81 T No. of Bolts required 4
U'2 - L'1
Member size = MC 300
Force = -55.46 T Tension [STAAD file ...... Stage 8]
Factored force = -83.19 T
Bolt value = 6.81 T No. of Bolts required 14
U'2 - L'2
Member size = MC 300
Force = 54.55 T Compression [STAAD file ...... Stage 8]
Factored force = 81.83 T
Bolt value = 6.81 T No. of Bolts required 14
Gusset thickness = 16 mm
Bolt size = 20 mm
Bolt value = 6.81 T
U'2 - U'3
Member size = MC 300
Force = 15.64 T Compression [STAAD file ...... Stage 10]
Factored force = 23.46 T
Bolt value = 6.81 T No. of Bolts required 4
U'3 - U'4
Member size = MC 200
Force = -2.49 T Tension [STAAD file ...... Stage 10]
Factored force = -3.74 T
Bolt value = 6.81 T No. of Bolts required 2
U'3 - L'2
Member size = MC 300
Force = -67.73 T Tension [STAAD file ...... Stage 10]
Factored force = -101.60 T
Bolt value = 6.81 T No. of Bolts required 16
U'3 - L'3
Member size = MC 300
Force = 66.32 T Compression [STAAD file ...... Stage 10]
Factored force = 99.48 T
Bolt value = 6.81 T No. of Bolts required 16
Gusset thickness = 16 mm
Bolt size = 20 mm
Bolt value = 6.81 T
U'3 - U'4
Member size = MC 200
Force = 8.52 T Compression [STAAD file ...... Stage 7]
Factored force = 12.78 T
Bolt value = 6.81 T No. of Bolts required 2
U'4 - U'5
Member size = MC 200
Force = 13.97 T Compression [STAAD file ...... Stage 6]
Factored force = 20.96 T
Bolt value = 6.81 T No. of Bolts required 4
U'4 - L'3
Member size = MC 200
Force = -46.52 T Tension [STAAD file ...... Stage 7]
Factored force = -69.78 T
Bolt value = 6.81 T No. of Bolts required 12
U'4 - L'4
Member size = MC 300
Force = 45.85 T Compression [STAAD file ...... Stage 7]
Factored force = 68.78 T
Bolt value = 6.81 T No. of Bolts required 12
Gusset thickness = 12 mm
Bolt size = 20 mm
Bolt value = 6.81 T
U'5 - U'6
Member size = MC 200
Force = 5.67 T Compression [STAAD file ...... Stage 6]
Factored force = 8.51 T
Bolt value = 6.81 T No. of Bolts required 2
U'6 - U'7
Member size = MC 150
Force = -3.05 T Tension [STAAD file ...... Stage 6]
Factored force = -4.58 T
Bolt value = 6.81 T No. of Bolts required 2
L'5 - U'6
Member size = MC 200
Force = -33.21 T Tension [STAAD file ...... Stage 6]
Factored force = -49.82 T
Bolt value = 6.81 T No. of Bolts required 8
L'6- U'6
Member size = MC 200
Force = 32.75 T Compression [STAAD file ...... Stage 6]
Factored force = 49.13 T
Bolt value = 6.81 T No. of Bolts required 8
Gusset thickness = 12 mm
Bolt size = 20 mm
Bolt value = 6.81 T
U'7 - U'7
Member size = MC 150
Force = 4.83 T Compression [STAAD file ...... Stage 5]
Factored force = 7.25 T
Bolt value = 6.81 T No. of Bolts required 2
U'8 - U'9
Member size = MC 150
Force = -4.42 T Tension [STAAD file ...... Stage 5]
Factored force = -6.63 T
Bolt value = 6.81 T No. of Bolts required 2
L'7 - U'8
Member size = MC 150
Force = -18.74 T Tension [STAAD file ...... Stage 5]
Factored force = -28.11 T
Bolt value = 6.81 T No. of Bolts required 6
L'8- U'8
Member size = MC 150
Force = 18.66 T Compression [STAAD file ...... Stage 5]
Factored force = 27.99 T
Bolt value = 6.81 T No. of Bolts required 6
Gusset thickness = 12 mm
Bolt size = 20 mm
Bolt value = 6.81 T
U'10 - U'11
Member size = MC 150
Force = 0.50 T Compression [STAAD file ...... Stage 4]
Factored force = 0.75 T
Bolt value = 6.81 T No. of Bolts required 2
U'11 - U'12
Member size = MC 150
Force = -2.89 T Tension [STAAD file ...... Stage 4]
Factored force = -4.34 T
Bolt value = 6.81 T No. of Bolts required 2
L'10 -U'11
Member size = MC 150
Force = -13.31 T Tension [STAAD file ...... Stage 4]
Factored force = -19.97 T
Bolt value = 6.81 T No. of Bolts required 4
L'11 -U'11
Member size = MC 150
Force = 13.44 T Compression [STAAD file ...... Stage 4]
Factored force = 20.16 T
Bolt value = 6.81 T No. of Bolts required 4
LAUNCHING TRUSS
TRESTLES
DESIGN OF ANCHORAGE DEPTH OF
REINFORCEMENT ON PIER CAPS P6 & P9