Professional Documents
Culture Documents
parameter action
Reactor Higher Higher Runaway Coolant Provide
temperature reactor reaction in pump to temperature
temperature reactor reactor fails control
Provide high
temperature
sensor/alarm
Provide
pressure
relief valve
with
automatic
feed from
temperature
control
system
Coolant Use heat
temperature exchanger
high temperature
control to
adjust inlet
cooler
temperature
Lower Lower Poor or no Coolant Provide
reactor reaction; poor temperature temperature
temperature quality product low monitoring
in reactor
Use heat
exchanger to
adjust inlet
coolant
temperature
Flow rate No No flow Level build up Melt pump Provide level
in reactor fails control in
reactor with
automatic
flow through
a spare
pump
Less Less flow System upset; Make up or Provide a
product quality recycle spare
affected; compressor compressor
system failure with
shutdown automatic
switch from
the failed
compressor
More More flow More Initiator Provide
(initiator) polymerization; pump adequate
possibility of malfunction flow control
runaway on both
conditions; initiator and
product quality monomer
off lines to
specifications maintain the
desired
initiator to
monomer
ratio
Less Less flow Less Make up and Provide flow
(initiator) polymerization; recycle gas controllers
reaction compressor on ethylene
temperature failure and initiator
imbalance lines
affects
downstream
equipment
such as heat
exchanger