Professional Documents
Culture Documents
S/N: 193674
LIT-1250 Level Indicating transmitter for liquids levels in USA CSA XP Class1 Div 1
T-1250 Gr A,B,C,D
LSH-1250 Electronic shut off switch that actuates when USA CSA XP Class1 Div 1
liquid level rises above the high level in T-1250. Gr A,B,C,D
Disables flow to the condensate absorber
package.
LSL-1250 Electronic shut off switch that actuates when USA CSA XP Class1 Div 1
liquid level rises below the low level in T-1250. Gr A,B,C,D
Disables flow out of the condensate absorber
package.
PSV-1250 Pressure Relief Valve to protect the condensate CANADA ASME Section VIII /
absorber tower and bottoms exchanger API 526
FE/ FIT-1250 Flow Element and Transmitter
TW / TI-1250 Thermowell with temperature indicator CANADA ASME B40.200 / ASME
B16.5
TW / TI-1251 Thermowell with temperature indicator CANADA ASME B40.200 / ASME
B16.5
TW-1260 Thermowell CANADA ASME B16.5
TW / TI-1261 Thermowell with temperature indicator CANADA ASME B40.200 / ASME
B16.5
TW-1262 Thermowell CANADA ASME B40.200 / ASME
B16.5
TW-1263 Thermowell with temperature indicator CANADA ASME B16.5
TW / TI-1264 Thermowell with temperature indicator CANADA ASME B40.200 / ASME
B16.5
PI-1250 Pressure indicator CANADA ASME B40.100 / ASME
B16.5