You are on page 1of 15

LAMPIRAN

Daftar Alat yang Digunakan pada Residue Catalytic Cracking Unit


PT PERTAMINA RU VI Balongan

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
Unit Residue Catalytic Cracking Unit
a. Reaktor
Tabel Daftar Reaktor yang digunakan di Unit RCU
Desain Material
No Tag No. Deskripsi Service
MWAP Temperatur Kons.
(kg/cm2g) (oC)
1 15-R-101 Reaktor HC/CAT 2,8/3,0 550 1,25Cro.5.Mo
2 15-R-102 Spent Catalytic Stripper HC/CAT 4,35/4,6 550 1,25Cro.5.Mo
3 15-R-103 First Stage Regeneration HC/CAT 3,5/3,85/3,95 343/788 KCs
4 15-R-104 Second Stage Regeneration HC/CAT 4,85 343/789 KCs

b. Kolom
Tabel Daftar Kolom yang digunakan di Unit RCU
Desain Material
No Tag No. Deskripsi Service
MWAP Temperatur Kons.
(kg/cm2g) (oC)
1 15-C-101 Main Column HC 2,5 510/340 1,25Cro.5.Mo
2 15-C-102 Net Bottom Stripper HC 2,8 400 Cs
3 15-C-103 LCO Stripper HC 2,8 260 Cs

c. Vin Fan
Tabel Daftar Fin Fan yang digunakan di Unit RCU
Desain Material
No Tag No. Deskripsi Service
MWAP Temperatur Kons.
(kg/cm2g) (oC)
ASME - VI I
1 15-E-108 Light Cycle Cooler HC 15,8 260
I DIV. I
Circullating Heavy Naptha ASME - VI I
2 15-E-109 HC 5,8 170
Cooler I DIV. I
Main Column Overhead ASME - VI I
3 15-E-110 HC 2,5 130
Condenser I DIV. I

d. Furnace
Tabel Daftar Furnace yang digunakan di Unit RCU
Desain Material
No Tag No. Deskripsi Service
MWAP Temperatur Kons.
(kg/cm2g) (oC)
1 15-F-101 Direct Fire Air Heater Air 5,5 343 N/A
Catalyst Coller Steam
2 15-F-102 Steam FV/50 478/406 2,25CR-1Mo
Superheater
ASME - I
3 15-B-101 CO Boiler Steam 53,9 396
DIV. 2

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
e. Vessel
Tabel Daftar Vessel yang digunakan di Unit RCU
Desain
No Tag No. Deskripsi Service Material Kons.
MWAP Temperatur
(kg/cm2g) (oC)
1 15-V-101 Cat Cooler Steam Dissengaging Drum Steam-Water 50 270 ASME - VI I I DIV. I
2 15-V-102 Frsh Catalyst Storage Hopper CAT 6,3/9,1 120/120 ASME - VI I I DIV. I
3 15-V-103 Low Metal Equilibrium Catalyst Storage Hopper CAT 6,3/9,2 120/121 ASME - VI I I DIV. I
4 15-V-104 High Metal Equilibrium Catalyst Storage Hopper CAT 4,6/7,4 400/400 ASME - VI I I DIV. I
5 15-V-105 Row Oil Surge Drum HC 2,8 250 ASME - VI I I DIV. I
6 15-V-106 Main Column Overhead Receiver HC 2,5 120 ASME - VI I I DIV. I
7 15-V-107 Intermitten Blowdown Drum Steam-Water atm 100 ASME - VI I I DIV. I
8 15-V-108 Continous Blowdown Drum Steam-Water 5,3 175 ASME - VI I I DIV. I
9 15-V-109 Fuel Gas Knock Out Drum Gas 5 160 ASME - VI I I DIV. I
10 15-V-110 With Drawal Catalyst Cooling Vessel CAT 5,45 343/788 ASME - VI I I DIV. I
11 15-V-112 LP Condensate Flash Drum Steam-Water 3,5 120 ASME - VI I I DIV. I
12 15-V-113 MP Condensate Flash Drum Steam-Water 5,3 320 ASME - VI I I DIV. I
13 15-V-114 Phospate Injector Package Chemical atm 60 N/A
14 15-V-115 Aromatic Drain Accumulation Chemical 10 80 ASME-A1A1
15 15-V-116 Phospate injection Satelitte Tank Chemical atm 60 N/A
16 15-V-117 CO Boiler Steam Drum Steam-Water 53,9 268 ASME I
17 15-V-118 Backwash Receiving Vessel Water 4 400 ASME I I I
18 15-V-119 Hopper Filter Receiver CAT 11 85 ASME I I I
19 15-V-120 Hopper Filter Receiver CAT 11 85 ASME I I I
20 15-V-121 Hopper Filter Receiver CAT 11 85 ASME I I I
21 15-V-601 Flare Knockout Drum HC 3,5 235 ASME DIV I

f. Heat Exchanger
Tabel 4.16 Daftar Heat Exchanger yang digunakan di Unit RCU
Material
Desain Shell Desain Tube
No Tag No. Deskripsi Service Kons.
MWAP Temperatur MWAP Temperatur
(kg/cm2g) (oC) (kg/cm2g) (oC)
Hot Net Bottom Raw Oil
1 15-E-101 HC/KC 25,1 250 24 400 CS/SS
HE
Cold Net Bottom Raw Oil
2 15-E-102 HC/HC 30,4 220 24 400 CS/SS
HE
3 15-E-103 Net Bottom Cooler HC 24 400 16 75 SC/SS
Main Column Bottom
4 15-E-104 HC/Water 29 390 19,4 400 CS/SC
Steam
Circullating Main Column 5 OCR-0,5
5 15-E-105 HC 25,1 300 16,7 400
Bottom Mo/CS
Main Column Bottom CS/1 CR-
6 15-E-106 HC/Steam 29 340 19,4 400
Super HE 0,2 Mo/SS
CS/1 CR-
7 15-E-107 LCO/Raw Oil HE HC/KC 30,4 200 20,3 260
0,2 Mo/SS
15-E- Main Column Overhead CS/1 CR-
8 HC/Water 2,5 120 6,5 75
11A/B/C/D Trim Condensor 0,2 Mo/SS
Condensate Flash Drum
9 15-E-114 Steam/Condensate 3,5 160 6,5 75 CS
Vent Condenser

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
g. Kompresor
Tabel Daftar Kompresor yang digunakan di Unit RCU

Desain
Material
No Tag No. Deskripsi Service Type Max. Suc. Max. Dif.
Temperatur Kons.
Pressure Head
(oC)
(kg/cm2g) (kg/cm2g)
1 15-K-101 MAB Air Axial 4,9 N/A CI/SS
15-K-102 Forced Draft Fan For CO
2 Air Centrifugal 0,033 31 CS/CORTEN
A/B Boiler
3 15-K-103 Plant Air Compressor Air Centrifugal 12,3 250 CI/SS

4 15-K-104 CO Boiler Seal Air Fan Air Centrifugal CS/CORTEN

h. Pompa
Tabel Daftar Pompa yang digunakan di Unit RCU

Desain
Material
No Tag No. Deskripsi Service Type Pump Max. Suc. Max. Dif.
Temperatur Kons.
Pressure Head
(oC)
(kg/cm2g) (kg/cm2g)
15-P-101 Circullating Main
1 HC Centripugal 28,8 58 400 CS
A/B/C Bottom Column
15-P-102
2 Net Bottom HC Centripugal 52,7 224 400 CS
A/B/C
3 15-P-103 A/B Main Column Reflux HC Centripugal 15 84 71 CS
Circullating Heavy Cycle
4 15-P-104 A/B HC Centripugal 15 315 75,3 CS
Oil
5 15-P-105 A/B Raw Oil HC Centripugal 26 235 223,5 CS
Circullating Light Cycle
6 15-P-106 HC Centripugal 11 260 58 CS
Oil
7 15-P-107 LCO HC Centripugal 30 260 138,7 CS

8 15-P-108 Net Overhead HC Centripugal 30 71 282,8 CS


Circullating Heavy
9 15-P-109 A/B HC Centripugal 13 166 74 CS
Naptha
10 15-P-110 A/B Sour Water Water Centripugal 30 71 58 CS
15-P- Catalyst Cooler
11 HBW Centripugal 63 282 116 LL/DIV 2
111A/B/C Circulating Water
MAB Surface Condensor
12 15-P-112 A/B Water Centripugal -0,83 0 15 API 610 CS
Valve
13 15-P-113 A/B RCC Condensate Return Water Centripugal 26 158 50,3 CL DIV 2
Chemical Injection Positive
14 15-P-114 Phospate 0 AMB CS
Package Pump Displacement
Chemical Injection Positive
15 15-P-115 Phospate 0 AMB CS
Package Pump Displacement
Chemical Injection Positive
16 15-P-116 Phospate 0 AMB API 675
Package Pump Displacement
Chemical Injection Positive
17 15-P-117 Phospate 0 AMB API 675
Package Pump Displacement
18 15-P-601 A/B Flare K.O Drum Pump HC/Water Centripugal 30 263 69,4 CL 1 DIV 2

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
19 15-P-901 A/B Oily Water Pump Oil Centripugal 4 73 26,5

20 15-P-902 Oily Sump Pump Oil Centripugal 8 50 62,7

i. Control Valve
Tabel Daftar Control Valve yang digunakan di Unit RCU
Tipe
No Desain
Instrumentasi Material
Tag. No Deskripsi Service
MWAP Konst.
Temperature
(kg/cm2g)
1 Control Valve 15-FV-001 Cat Addition Transfer Air AIR 29.0 60.0 A216WCB
2 Control Valve 15-FV-002 Aeration Air High Metal Cat AIR/CAT 28.4 600 A216WCB
3 Control Valve 15-FV-003 Air To 2Nd Stage Regenerator AIR 28.4 212 A216WCB
4 Control Valve 15-FV-005 Steam To Feed Distribution Nozzle STEAM 18.0 370 A216WCB
5 Control Valve 15-FV-006 Steam To Rises Bottom STEAM 18.0 370 A216WCB
6 Control Valve 15-FV-007 Emergency Steam To Riser STEAM 18.0 370 A216WCB
7 Control Valve 15-FV-008 Lift Gas To Riser GAS 14.8 120 A216WCB
8 Control Valve 15-FV-009 Start Up Hc To Riser HC 0.744 120 A216WCB
9 Control Valve 15-FV-010 Steam To Spent Cat Stripper Upper STEAM 18.0 360 A216WCB
10 Control Valve 15-FV-011 Steam To Spent Cat Stripper Lower STEAM 18.0 350 A216WCB
11 Control Valve 15-FV-012 Air To Withdrawal Cat Vessel AIR 28.4 212 A216WCB
12 Control Valve 15-FV-013 Air To Withdrawal Transport Air AIR 28.4 212 A216WCB
13 Control Valve 15-FV-014 Fluidizing Air Though E 113A AIR 28.4 60 A216WCB
14 Control Valve 15-FV-015 Water Flow To E 113A WATER 0.790 288 A216WCB
15 Control Valve 15-FV-018 Bfw To Cat Cooler Steam WATER 0.923 160 A216WCB
16 Control Valve 15-FV-026 Bfw To Cat Co Boiler WATER 0.923 160 A216WCB
17 Control Valve 15-FV-034 Air To 1St Stage Regenerator AIR 28.4 212 A216WCB
15-FV-
18 Control Valve Torch Oil To 1St Stage Regenerator RAW OIL 0.803 316 5%CR1/2%Mo
035A
15-FV-
19 Control Valve 1St Stage Regenerator Torch Oil St RAW OIL 18.0 370 A216WCB
035B
15-FV- Torch Oil To 2Nd Stage
20 Control Valve RAW OIL 0.803 316 5%CR1/2%Mo
039A Regenerator
15-FV-
21 Control Valve 2Nd Stage Regenerator Torch Oil St RAW OIL 18.0 370 A216WCB
039B
22 Control Valve 15-FV-040 Water Flow To E 113B WATER 0.790 288 A216WCB
23 Control Valve 15-FV-041 Water Flow To E 113C WATER 0.790 288 A216WCB
24 Control Valve 15-FV-042 Water Flow To E 113D WATER 0.790 288 A216WCB
25 Control Valve 15-FV-043 Air Flow To E-113B AIR 28.4 60 A216WCB
26 Control Valve 15-FV-044 Air Flow To E-113C AIR 28.4 60 A216WCB
27 Control Valve 15-FV-045 Air Flow To E-113D AIR 28.4 60 A216WCB
Fluffing Air To 1St Stage
28 Control Valve 15-FV-046 AIR 28.4 212 A216WCB
Regenerator
Fluffing Air To 1St Stage
29 Control Valve 15-FV-047 AIR 28.4 212 A216WCB
Regenerator
Fluffing Air To 1St Stage
30 Control Valve 15-FV-048 AIR 28.4 212 A216WCB
Regenerator
Fluffing Air To 1St Stage
31 Control Valve 15-FV-049 AIR 28.4 212 A216WCB
Regenerator
32 Control Valve 15-FV-072 Steam To P 111C STEAM 18.0 370 A216WCB

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
Tipe
No Desain
Instrumentasi Material
Tag. No Deskripsi Service
MWAP Konst.
Temperature
(kg/cm2g)
33 Control Valve 15-FV-501 Atmos Residue From Storage RAW OIL 0.906 105 A216WCB
34 Control Valve 15-FV-502 Atmos Residue From Met Storage RAW OIL 0.837 105 A216WCB
35 Control Valve 15-FV-503 Treated Residue From Met Storage RAW OIL 0.776 250 A216WCB
36
Control Valve 15-FV-504 Hco Reflux To C 101 HC 0.803 316 5%CR1/2%Mo
37
Control Valve 15-FV-505 Main Column Reflux HC 0.744 120 A216WCB
38
Control Valve 15-FV-506 C 101 Net Overhead Liquid HC 0.744 120 A216WCB
39
Control Valve 15-FV-509 Heavy Naptha Bypass To Cooler HC 0.724 170 A216WCB
40
Control Valve 15-FV-510 Stripping Steam To Lco Stripper STEAM 18.0 370 A216WCB
41
Control Valve 15-FV-511 Crude From Distilation Unit RAW OIL 0.846 200 A216WCB
42
Control Valve 15-FV-512 Lco To Lco Hydrotreater HC 0.810 260 A216WCB
43
Control Valve 15-FV-513 Lco Product To Storage HC 0.900 150 A216WCB
44
Control Valve 15-FV-515 Hco To Reactor Riser HC 0.803 288 5%CR1/2%Mo
45
Control Valve 15-FV-518 Bfw To E 104A WATER 0.923 160 A216WCB
46
Control Valve 15-FV-523 Bfw To E 104B STEAM 0.923 160 A216WCB
47
Control Valve 15-FV-525 Stripping Steam To Net Bottom STEAM 18 370 A216WCB
48
Control Valve 15-FV-526 Raw Oil To Raw Oil Exchanger RAW OIL 0.811 250 A216WCB
49
Control Valve 15-LV-007 Condensate From Blowdown Drum WATER 0 120 A216WCB
50
Control Valve 15-LV-503 Sour Water Stripper WATER 0.922 120 A216WCB
51
Control Valve 15-LV-505 Lco Stripper Feed HC 0.755 400 A216WCB
52
Control Valve 15-PV-006 Pa To Cat Strorage Hopper AIR/CAT 29 120 A216WCB
53
Control Valve 15-PV-017 Steam To Purge Steam Riser STEAM 18 370 A216WCB
54
Control Valve 15-PV-018 Gas To Purge Gas Riser GAS 1.6 65 A216WCB
55
Control Valve 15-PV-026 Fuel Gas To Cob Supply Burner GAS 14.6 65 A216WCB
56
Control Valve 15-PV-029 Pa To High Metal Cat Storage AIR/CAT 29 65 A216WCB
57
Control Valve 15-PV-501 C 101 Ovhd To Relief Header HC 36.8 120 A216WCB
58 15-TDV-
Control Valve Mab Discharge Vent AIR 28.2 212 A216WCB
012
59
Control Valve 15-TV-013 Fuel Gas To Dfah GAS 21.3 65 A216WCB
60
Control Valve 15-TV-524 Bfw To Mp Steam Desuperheater WATER 0.923 160 A216WCB
61 15-TV-
Control Valve Raw Oil From Raw Oil Exchanger RAW OIL 0.771 310 5%CR1/2%Mo
530A
62 15-TV- Raw Oil By Pass Raw Oil
Control Valve RAW OIL 0.807 250 A216WCB
530B Exchanger
63
Control Valve 15-UV-016 Cob Fuel Gas Header Shutoff GAS 14.6 65 A216WCB
64
Control Valve 15-UV-18A Purge Steam Cob STEAM 18 290 A216WCB
65
Control Valve 15-UV-18B Purge Steam Cob STEAM 18 290 A216WCB

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
Tipe
No Desain
Instrumentasi Material
Tag. No Deskripsi Service
MWAP Konst.
Temperature
(kg/cm2g)
33 Control Valve 15-FV-501 Atmos Residue From Storage RAW OIL 0.906 105 A216WCB
34 Control Valve 15-FV-502 Atmos Residue From Met Storage RAW OIL 0.837 105 A216WCB
66
Control Valve 15-UV-029 Transfer Air To Fresh Cat Hopper AIR 29.0 60 A216WCB
67
Control Valve 15-UV-030 Transfer Air To Low Metal Hopper AIR 29.0 60 A216WCB
68
Control Valve 15-UV-031 Transfer Air To Cat Cooling AIR 28.4 60 A216WCB
69
Control Valve 17-UV-009 Fuel/Offgas To 11-F-101 GAS 14.8 0 A216WCB
70 17-UV-
Control Valve Fuel/Offgas To 11-F-102 GAS 18.6 0 A216WCB
007A
71 17-UV-
Control Valve Fuel/Offgas To 11-F-103 GAS 14.8 0 A216WCB
001B
72
Control Valve 15-LV-303 Lc From 15-V-112 COND 0.959 0 A216WCB
73
Control Valve 15-LV-301 Lc From 15-V-113 COND 0.920 0 A216WCB
74 15-PDV-
Control Valve Ms To F 102 STEAM 1.8 0 A216WCB
037
75
Control Valve 15-PV-038 Fo To F 102 OIL 0.992 80 A216WCB
76
Control Valve 15-PV-037 Fg To F 102 GAS 14.6 65 A216WCB
77
Control Valve 15-UV-038 Ms To P 112B STEAM 18.0 0 A216WCB
78
Control Valve 15-UV-039 Air To Sootblower AIR 28.4 0 A216WCB

Unit Light End Unit


a. Reaktor
Tabel Daftar Reaktor yang digunakan di Unit LEU
Desain Material
No Tag No. Deskripsi Service
2 o
Kons.
MWAP (kg/cm g) Temperatur ( C)
1 19-R-101 SHP Reaktor 46,7 110 CS
2 20-R-101 A Reaktor 213/FV 238/210 KCS

b. Kolom
Tabel Daftar Kolom yang digunakan di Unit LEU
Desain Material
No Tag No. Deskripsi Service
MWAP Temperatur Kons.
(kg/cm2g) (oC)
1 16-C-101 Primary Absorber HC 16,2 120 CS/CS
2 16-C-102 Sponge Absorber HC 15,8 120 CS/410 SS
3 16-C-103 Stripper HC 17,9 156 CS/CS
4 16-C-104 Debutanizer HC 12,7 226 CS
5 16-C-105 RCC Unsaturated Gas Absorber HC 15,3 71 CS
6 19-C-101 C3/C4 Splitter HC 21 134 KCS/CS
7 19-C-102 C3 Splitter HC 16,8 95 KCS/CS

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
Desain Material
No Tag No. Deskripsi Service
MWAP Temperatur Kons.
(kg/cm2g) (oC)
8 19-C-103 Water Wash Column Water 36 110 KCS/CS
9 20-C-101 Water Wash Column Water 22 120 CS
10 20-C-102 Fresh Rectifier HC 8,5 120 CS
11 20-C-103 Stabilizer HC 9,9 120 CS

c. Air Cooled Heat Exchanger


Tabel Daftar Air Cooled Heat Exchanger yang digunakan di Unit LEU
Desain
No Tag No. Deskripsi Service Material Kons.
MWAP Temperatur
(kg/cm2g) (oC)
1 16-E-117 Debutaniser Overhead Condenser HC 12,7 120 TD 8403
2 16-E-119 Compressor Interstage Cooler HC/H2/H2O 6 120 TD 8404
3 16-E-120 High Pressure Condenser HC/H2/H2O 18,1 120 TD 8405
4 16-E-121 Sponge Absober Lean Oil Cooler HC 9,7 146 TD 8406
5 16-E-123 Debutanizer Bottom Cooler HC 14 132 TD 8407
6 16-E-104 Stabilizer Bottom Cooler HC 10,4 140 API 664
7 16-E-107 Flash Rectifier Trim Condenser HC 8,5 120 API 664
8 16-E-108 Stabilizer Kondenser HC 9,9 120 API 664

d. Vessel

Tabel Daftar Vessel yang digunakan di Unit LEU

Desain
No Tag No. Deskripsi Service Material Kons.
MWAP Temperatur
(kg/cm2g) (oC)
1 16-V-103 Water Injection Tank Water ATM 120 N/A
2 16-V-104 Hight Pressure Receiver 16,6 120 ASME VIII DIV. 1
3 16-V-105 Lean Gas Knockout Drum 16,3 120 ASME VIII DIV. 1
4 16-V-106 Debutanizer Receiver HC 12,7 120 ASME VIII DIV. 1
5 16-V-107 Rcc Unsaturated Treated Gas Knockout Drum 15 65 ASME VIII DIV. 1
6 16-V-108 Rcc Amine Reciver ATM 60 ASME VIII
7 16-V-109 Chilled Water Header Tank ATM 75 ASME VIII DIV. 1
8 16-V-110 Oil reservoir/Separator 24,6 149 ASME VIII
9 16-V-111 R-22 Reciver 24,6 149 ASME VIII
10 16-V-112 Intercooler 24,6 149 ASME VIII
11 17-V-101 Phasse Separator 21 65 ASME VIII DIV. 1
12 17-V-102 Phasse Separator 21 65 ASME VIII DIV. 1
13 17-V-103 Phasse Separator 21 65 ASME VIII DIV. 1
14 17-V-104 Phasse Separator 21 65 ASME VIII DIV. 1
15 17-V-105 Oxidizer Separator 11 65 ASME VIII DIV. 1
16 17-V-106 Phasse Separator 11 65 ASME VIII DIV. 1
17 18-V-101 Phasse Separator 14 65 ASME VIII DIV. 1
18 18-V-102 Phasse Separator 14 65 ASME VIII DIV. 1
19 18-V-103 Inhibitor Tank ATM 37,7 N/A

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
Desain
No Tag No. Deskripsi Service Material Kons.
MWAP Temperatur
(kg/cm2g) (oC)
20 18-V-104 Water Break Tank ATM 48 N/A
21 19-V-101 C3/c4 Spliter Recever HC 21 120 ASME VIII DIV. 1
22 19-V-102 C4 Spliter Flash Drum HC 15,8 120 TYPE 4
23 19-V-103 Solvent Setter Solvent 31,8 66 ASME VIII DIV. 1
24 19-V-104 C3 Feed Dryers HC 36 260 ASME VIII DIV. 1
25 19-V-105 Caustik Degassing Drum Caustik 3,5 66 ASME VIII DIV. 1
26 19-V-106 Water Degassing Drum Water 3,5 120 ASME VIII DIV. 1
27 19-V-108 Solvent Tank Solvent 4,2 120 ASME VIII DIV. 1
28 19-V-109 Phosphate MEA Tank Phosphate ATM 120
29 19-V-110 Wash Water Tank Wash ATM 120
30 19-V-111 Propylene Metal Treater Propylene 46,7 120 ASME VIII DIV. 1
31 19-V-112 Cos Removal Water 46,7 120 ASME VIII DIV. 1
32 16-V-101 Compressor Suction Drum Propylene 3,5 120 CS
33 16-V-102 Interstage Receiver 5,2 120 CS
34 20-V-101 Feed Surge Drum 8,5 120 KCS
35 20-V-102 Flash Rectifier Receiver 8,5 120 KCS
36 20-V-103 Stabilizer Receiver 9,9 120 KCS
37 20-V-104 Wash Water Tank Off gas ATM 120 KCS
38 20-V-105 Water Injection Tank HC ATM 120 KCS
39 20-V-106 Caustic Wash HC 21 66 KCS

e. Heat Exchanger
Tabel Daftar Heat Exchanger yang digunakan di Unit LEU
Material
Desain Shell Desain Tube
No Tag No. Deskripsi Service Kons.
MWAP Temperatur MWAP Temperatur
(kg/cm2g) (oC) (kg/cm2g) (oC)
16-E-101 Compressor Interstage
1 HC/WATER 5,6 120 6,5 75 KCS
A/B Trim Cooler
16-E-102
2 High Pessure Trim Cooler HC/WATER 17,8 120 11,9 75 KCS
A/B
16-E-103 Primary Absober Feed HC/CHILLED
3 27 120 18 75 KCS
A/B Cooler WATER
16-E-104 Primary Absober Upper HC/CHILLED
4 21,7 120 14,5 75 KCS
A/B Intercooler WATER
16-E-105 Primary Absober Lower HC/CHILLED
5 21 120 14 75 KCS/CS
A/B Intercooler WATER
Sponge Absober Lean
6 16-E-106 HC/HC 6,9 123 9,8 232 KCS/CS
Rich Oil Exchanger
Sponge Absober Lean Oil
7 16-E-107 HC/WATER 9,8 120 6,5 75 CS
Trim Cooler
8 16-E-108 Stripper Feed Exchanger HC/HC 20,9 120 14 183 KCS/CS
HC/COOLER
9 16-E-109 Lead Gas Cooler 16,2 120 10,2 75 KCS/CS
WATER
16-E-111 Debutanizer Bottem HC/CHILLED
10 29,3 120 19,5 76 CS
A/B Recycle Cooler WATER
11 16-E-113 Stipper Reboiler Excanger HC/HC 18,5 145 14 210 CS

12 16-E-114 Stripper Reboiler HC/HC 18,5 156 12,3 260 CS

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
Desain Shell Desain Tube
No Tag No. Deskripsi Service Material
MWAP Temperatur MWAP Temperatur Kons.
(kg/cm2g) (oC) (kg/cm2g) (oC)
16-E-116
14 Debutaniser Reboiler HC/HC 13,4 226 11 316 CS
A/B
Debutaniser Net Overhead HC/COOLER
15 16-E-118 21 120 14 75 CS
Cooler WATER
16-E-124 Debutaniser Bottom Trim HC/COOLER
16 14 129 9,3 75 CS
A/B Cooler WATER
17 16-E-125 Surface Condenser CONDENSATE 0,5 150 6,5 75 CS

18 16-E-126 R - 22 Condenser N/A 24,6 149 10,5 149 CS

19 17-E-101 Caustic Heater H/NI 14 325 21 290 CS


C3/C4 Spliter
20 19-E-101 HC 23 120 22 120 CS
Feed/Bottem Exchanger
21 19-E-102 C3/C4 Spliter Condenser HC 21 120 14 75 CS

22 19-E-103 C3/C4 Spliter Reboiler HC 22 134 14,7 166 CS


C3/C4 Spliter Net Bottem
23 19-E-104 HC 21,9 120 14,6 75 CS
Cooler
24 19-E-105 C3 Spliter Reboiler HC 17,4 110 27 120 CS
C3 Spliter Trim
25 19-E-106 HC 27 120 18 75 CS
Condenser
C3/C4 Spliter Overhead
26 19-E-107 HC 36 120 24 75 CS
Product Cooler
27 19-E-108 SHP Effluent HC 32 325 46,7 130 CS

28 19-E-109 SHP Feed Peheater HC/LP STEAM 46,7 120 32 75 CS

29 19-E-111 Regenerant Superheater HC 36 427 19,1 232 SS

30 19-E-112 Regenerant Vaporize HC/LP STEAM 36 120 24 325 CS


20-E-101
31 Combine Feed Excanger HC 46 175 43 238 CS/CS
A/B/C
20-E-102
32 Combine Feed Heater HC 43 210 50 412 CS/CS
A/B/C
Stabilizer Feed/Bottem
33 20-E-103 HC 11,2 151 10,4 239 CS/CS
Exchanger
34 20-E-105 Butane Product Cooler HC 21 120 14 75 CS/CS

35 20-E-106 Stabilizer Reboiler HC 10,4 248 50 421 CS/CS


Flash Rectifier Trim
36 20-E-109 HC 8,5 120 6,5 75 CS/CS
Condenser
Stabilizer Bottem Trim
37 20-E-110 HC 10,4 120 7 75 CS/CS
Cooler
Surface Condenser 19-K- STEAM/COOLING STEEL
38 19-E-110
101 WATER A516-70
Drawing Suface STEAM/COOLING
39 19-E-110
Condenser 19-K-101 WATER

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
f. Kompresor
Tabel Daftar Kompresor yang digunakan di Unit LEU

Desain
No Tag No. Deskripsi Service Type Max. Suc. Max. Dif. Material Kons.
Temperatur
Pressure Head
(oC)
(kg/cm2g) (kg/cm2g)
1 16-K-101 Wet Gas Compressor H2/HC CENTRIFUGAL 21,1 140 CS/SS
16-K-102
2 Refrigerant Compresor R-22 SCREW 17 71 CI
A/B
3 19-K-101 C3 Spliter Head Pump HC CENTRIFUGAL 40 27 A1S1 4140/CS
19-K-102 Propylene Unit Hydrogen ASTM
4 HC CENTRIFUGAL 275 55,9 49
A/B Compressor A182/SS

g. Pompa
Tabel Daftar Pompa yang digunakan di Unit LEU

Desain
Material
No Tag No. Deskripsi Service Type Pump Max. Suc. Max. Dif.
Temperatur Kons.
Pressure Head
(oC)
(kg/cm2g) (kg/cm2g)
16-P-101 Suction Drum POSITIVE
1 HC/WATER 9 43 CS
A/B Pump DISPLACEMENT
16-P-102 Interstage
2 HC/WATER CENTRIFUGAL 35 255 71 CS
A/B Comdenser
16-P-103
3 Water Injection WATER CENTRIFUGAL 30 82 76 CS
A/B
16-P-104 High Pressure
4 HC CENTRIFUGAL 25 97 71 CS
A/B Receiver
Primary Absorber
5 16-P-105 HC CENTRIFUGAL 22 42 52 CS
Upper Intercooler
16-P-106 Primary Absorber
6 HC CENTRIFUGAL 22 43 55 CS
A/B lower Intercooler
16-P-107 Primary Absorber
7 HC CENTRIFUGAL 23 67 68 CS
A/B Rich Oil
16-P-108 Sponge Absorber
8 HC CENTRIFUGAL 30 188 71 CS
A/B Lean Oil
Debutanizer
9 16-P-109 HC CENTRIFUGAL 30 180,9 66 CS
Bootem Receiver
16-P-110 Debutanizer
10 HC CENTRIFUGAL 21 121 77 CS
A/B Overhead
Rcc Amine Sump
11 16-P-112 CENTRIFUGAL 3 22,7 60 CS
Pump
16-P-113 Chiller Water
12 WATER CENTRIFUGAL 9 69 50 CS
A/B Circulating Pump
17-P101
13 Caustic Recycle CAUSTIC CENTRIFUGAL 13,4 40 CS
A/B
17-P-102
14 Caustic Recycle CAUSTIC CENTRIFUGAL 13,3 42 CS
A/B
17-P-103
15 Caustic Recycle CAUSTIC CENTRIFUGAL 13,2 42 CS
A/B
17-P-104
16 Water Recycle WATER CENTRIFUGAL 13 42 CS
A/B
17-P-105 Fresh Water
17 WATER METER AMB 38 31655
A/B Metering

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
Desain
.
Material
No Tag No. Deskripsi Service Type Pump Max. Suc. Max. Dif.
Temperatur Kons
Pressure Head
(oC)
(kg/cm2g) (kg/cm2g)
17-P-107
19 Caustic Regen CAUSTIC CENTRIFUGAL 2,8 52 CS
A/B
17-P-108
20 Caustik Booster CAUSTIC CENTRIFUGAL 3,87 38 CS
A/B
21 18-P101 Water Addition WATER CENTRIFUGAL ATM 42 CS
18-P102
22 Caustic Recycle CAUSTIC CENTRIFUGAL 4,9 38 CS
A/B
18-P104
23 Caustic Recycle CAUSTIC CENTRIFUGAL 4,9 38 CS
A/B
18-P105
24 Inhibitor Injection METER ATM 28 31655
A/B/C
19-P-101
25 Lpg Feed HC CENTRIFUGAL 38 206,1 68 CS/SS
A/B
19-P-102 C3/C4 Spliter
26 HC CENTRIFUGAL 36 270 76 CS/SS
A/B Reflux
19-P-103
27 Propane Product HC CENTRIFUGAL 12,7 38 CS/SS
A/B
19-P-104
28 C3 Spliter Reflux PROPANE CENTRIFUGAL 33 267,9 66 CS/SS
A/B
19-P-105
29 Propylene HC CENTRIFUGAL 46 486,4 55 CS/SS
A/B
19-P-106 Solvent
30 NaOH/WATER CENTRIFUGAL 62 26,5 66 CS/SS
A/B Circulation
19-P-107
31 Solvent Injection MEA CENTRIFUGAL 6 38 CS/SS
A/B
19-P-108 SOLVENT/
32 Solvent Transfer CENTRIFUGAL 38 247,7 66 CS/SS
A/B WATER
19-P-109 Wash Water
33 WATER CENTRIFUGAL 41 32,7 68 CS/SS
A/B Circulation
19-P-110 Phosphate
34 Na/H2/Po4 CENTRIFUGAL 48 38 CS/SS
A/B Injection
19-P-111 Wash Water
35 WATER CENTRIFUGAL 33 60 CS/SS
A/B Make Up
19-P-112 Sour Water
36 HC/WATER CENTRIFUGAL 30 59,2 68 CS/SS
A/B Transfer
19-P-113 Spent solvent WATER/MEA/
37 CENTRIFUGAL 30 37,6 66 CS/SS
A/B Transfer DEU/Na
38 19-P-901 Mea Sump Pump SPENT CAUSTIK CENTRIFUGAL 8 63 CS/SS
20-P-101
39 Charge Pumps HC CENTRIFUGAL 5,2 38 CS/SS
A/B
Wash Water
20-P-102
40 Circulating WATER CENTRIFUGAL 18,4 38 CS/SS
A/B
Pumps
20-P-103 Flash Rectifier
41 HC CENTRIFUGAL 8,9 71 CS/SS
A/B Recycle
Flash Rectifier
20-P-104
42 Trim Bottems HC CENTRIFUGAL 6,5 81 CS/SS
A/B
Pumps
Phosphate
43 20-P-105 PHOSPHATE METER 0 38 SS
Injection Pumps
20-P-106 Wash Water
44 WATER METER 0 38 SS
A/B Make Up Pumps
20-P-107 Stabilizer
45 HC CENTRIFUGAL 7,6 61 CS/SS
A/B Receiver
20-P-110 Reactor Water
46 WATER METER 0 38 SS
A/B/C Injection

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
h. Control Valve
Tabel Daftar Control Valve yang digunakan di Unit LEU
Tipe
Desain
No Instrumentasi Material
Tag. No Deskripsi Service
MWAP Konst.
Temperature
(kg/cm2g)
1 Control Valve 16-FV-001 Water Injection WATER 0.994 120 A216WCB
2 Control Valve 16-FV-004 Hp Liquid To Stripper 0.640 120 A216WCB
3 Control Valve 16-FV-006 Debutaniser Bottom Recycle HC 0.744 120 A216WCB
4 Control Valve 16-FV-007 Naphta To Naptha Treatment HC 0.723 120 A216WCB
5 Control Valve 16-FV-009 Lco From Stripper Reboiler HC 0.826 232 A216WCB
6 Control Valve 16-FV-010 Primary Absorber Rich Oil HC 0.670 120 A216WCB
7 Control Valve 16-FV-012 Lean Oil To Sponge Absorber HC 0.903 120 A216WCB
8 Control Valve 16-FV-014 Lco From Debutaniser Feed Ex HC 0.825 232 A216WCB
9 Control Valve 16-FV-015 Hco From Debutaniser Reboiler HC 0.855 316 5%CR1/2%Mo
10 Control Valve 16-FV-016 Hco From Debutaniser Reboiler HC 0.856 316 5%CR1/2%Mo
11 Control Valve 16-FV-017 Debutaniser Reflux HC 0.518 120 A216WCB
12 Control Valve 16-FV-018 Lpg To Lpg Treatment HC 0.532 120 A216WCB
13 Control Valve 16-FV-031 Lean Amine From 23-E-101 1.01 120 A216WCB
14 Control Valve 16-LV-001 Stm Cond TO Water Inj Tank COND 0.994 80 A216WCB
15 Control Valve 16-LV-003 Intr Stg Cond To Hp Receiver COND 0.657 120 A216WCB
16 Control Valve 16-LV-005 Hp Receiver Boot To Ovhd Con 0.992 120 A216WCB
17 Control Valve 16-LV-006 Stripper Bottoms HC 56.4 156 A216WCB
18 Control Valve 16-LV-008 Rich Oil From Sponge Absorber 26.1 120 A216WCB
19 Control Valve 16-LV-031 C 105 Unsat Gas Absorber HC 1.021 120 A216WCB
20 Control Valve 16-PV-009 Gas To Refinery Fuel Gas System GAS 14.6 120 A216WCB
21 Control Valve 16-PV-011 Debutaniser Ovhd Vapor HC 50.3 120 A216WCB
16-PDV-
22 Control Valve Debutaniser Ovhd Cond Bypass HC 50.2 120 A216WCB
012
16-PDV-
23 Control Valve A 101 HC 0.998 75 A216WCB
065
24 Control Valve 16-TV-001 Debutaniser Bottoms HC 0.661 183 A216WCB
16-XV-
25 Control Valve Wgc 1St Stage Spillback HC 36.7 130 A216WCB
001A
16-XV-
26 Control Valve Wgc 1St Stage Spillback HC 36.8 130 A216WCB
001B
16-XV-
27 Control Valve Wgc 2Nd Stage Spillback HC 34.7 142 A216WCB
002A
16-XV-
28 Control Valve Wgc 2Nd Stage Spillback HC 34.8 142 A216WCB
002B
29 Control Valve 16-UV-011 Condenser Pump 1.9 170 A216WCB
30 Control Valve 19-FV-002 C3/C4 Splitter Bottom To Storage HC 0.570 0 A216WCB
31 Control Valve 19-FV-003 Naphta From C3/C4 Splitter HC 0.758 0 A216WCB
32 Control Valve 19-FV-004 C3/C4 Splitter Ovhd Liquid HC 0.484 0 A216WCB
33 Control Valve 19-FV-005 C3/C4 Splitter Reflux HC 0.462 0 A216WCB
34 Control Valve 19-FV-010 C3 To Regenerator Vaporiser HC 0.477 0 A216WCB
35 Control Valve 19-FV-011 Propane Product HC 0.76 0 A216WCB

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
Tipe
Desain
No Instrumentasi Material
Tag. No Deskripsi Service
MWAP Konst.
Temperature
(kg/cm2g)
36 Control Valve 19-FV-012 C3 Splitter Reboiler Cond HC 0.470 0 A216WCB
37 Control Valve 19-FV-014 C3 Splitter Reflux HC 0.503 0 A216WCB
38 Control Valve 19-FV-015 C3 Splitter Ovhd To Dry Cos HC 0.503 0 A216WCB
39 Control Valve 19-FV-016 C3 Splitter Comp Spillback HC 42.1 0 A216WCB
40 Control Valve 19-FV-017 C3 Splitter Trim Cond Outlet HC 42.1 0 A216WCB
41 Control Valve 19-FV-019 Cond From Shp Feed Heater HC 18.0 0 A216WCB
42 Control Valve 19-FV-020 Propylene Pump Spillback HC 0.503 0 A216WCB
43 Control Valve 19-LV-003 C3/C4 Splitter Receiver Boot HC 0.990 0 CF8M
44 Control Valve 19-LV-006 Sour Water From Water Wash 0.990 0 A216WCB
45 Control Valve 19-LV-007 Cond To Wash Water Tank COND 0.994 0 A216WCB
46
Control Valve 19-LV-008 Sour Water To Stripping Unit 0.990 0 A216WCB
47
Control Valve 19-PV-001 Lpg Fedd Pumps Discharge HC 0.532 0 A216WCB
48
Control Valve 19-PV-002 C3/C4 Ovhd Vapor By Pass HC 42.5 0 A216WCB
49 19-PDV-
Control Valve Circulation To Solvent Settle SOLVENT 0.597 0 A216WCB
007
50
Control Valve 19-PV-011 C3 Feed To Dryers HC 0.447 0 A216WCB
51
Control Valve 19-PV-012 C3 Splitter Feed HC 42.5 0 A216WCB
52
Control Valve 19-PV-020 Propylene To Storage HC 0.487 0 A216WCB
53
Control Valve 19-PV-021 Mp Steam To Transfer P Turbine STEAM 18.0 370 A216WCB
54
Control Valve 19-UV-002 Elecrtolytic Hydrogen HC 2.0 0 A216WCB
55
Control Valve 19-KV-018 C3 Drayers HC 16.0 210 A216WCB

Laporan Kerja Praktik PT.PERTAMINA


(Persero) RU VI Balongan
Laporan Kerja Praktik PT.PERTAMINA
(Persero) RU VI Balongan

You might also like