You are on page 1of 2

FireWorks 1.

70 Software Upgrade
Installation Sheet
Introduction To start the FireWorks SSCP utility:

This document provides installation instructions for upgrading 1. Using Windows Explorer, open the Fireworks DVD.
your FireWorks computer to FireWorks 1.70. 2. If you are running FireWorks 1.41, open the Fireworks SSCP
Please read the FireWorks 1.70 Software Release Notes 1.41 folder.
(P/N 3100569-EN) and these instructions in their entirety before — or —
proceeding. The release notes are located on the FireWorks 1.70
DVD. If you are running FireWorks 1.5, open the Fireworks SSCP
1.5 folder.
3. Double-click FireworksStatistics.exe, and then click Start.
Recommended minimum system requirements
The SSCP report indicates the source of possible performance
For optimal performance, install FireWorks 1.70 on computers
issues in red.
that meet the following recommended minimum system
requirements:
• Windows 7 Ultimate 64-bit SP1 or Windows XP Professional Before you begin
SP3 The FireWorks 1.70 installation remains a multiple-step process.
• Intel Core 2 Duo Processor E8400 During the installation, your computer may automatically restart
• 2 GB RAM (4 GB recommended) or you may be asked to allow a reboot. Always allow a reboot
• 256 MB dedicated video RAM when asked and do not remove the installation DVD (or USB
• DVD drive flash drive) at any time during the installation.
• 250 GB hard drive
• Two or more USB 2.0 ports The installation can take up to 45 minutes or more, depending on
• 1280 × 1024 16-bit color display the speed of your computer, so be patient. Do not attempt to run
any other programs, or perform any other operations on the
Note: Do not install FireWorks 1.70 on computers that are computer when installing FireWorks 1.70.
running any other version of Microsoft Windows or any other
operating system — including operating systems that offer an Here are some things you should do before upgrading your
“XP  Emulation” mode. system:
• If your computer does not have a DVD drive, you need to
FWUL4 or UL4-class computers use an external DVD drive to install the software or copy the
FireWorks 1.70 DVD to a USB flash drive (4 GB or larger)
If you are upgrading FireWorks 1.41 or FireWorks 1.50 on an and use it to install the software.
FWUL4 or UL4-class computer, run the FireWorks SSCP utility
• Make a full backup of your project and then copy the
(system size calculation program) to determine if you could
C:\FireWorks\System\Backup folder to a safe location. For
encounter performance issues running FireWorks 1.70 with your
example, to an external hard drive or to a USB flash drive.
existing projects.
• Install the latest Windows updates. If you do not know how,
You should consider upgrading your computer hardware to meet
start Windows Help and Support, and then enter the search
the system requirements above if the FireWorks SSCP utility
phrase: windows update.
reveals that your FireWorks project has:
• Set your Power Scheme options for Never.
• More than 20 nodes
• Create a restore point. If you do not know how, start
• More than 19,500 points (physical or virtual)
Windows Help and Support, and then enter the search
• More than 1,000 points being processed by the DARCOM phrase: restore point.
software, including points from an iO series panel
• AutoCAD (DWG) map files that are larger than 1 MB or have Upgrading FireWorks 1.60
more than 20 TSAs
Run the FireWorks 1.70 DVD and follow the on-screen
Note: Minimizing AutoCAD (DWG) map files or converting them instructions. FireWorks 1.70 installs seamlessly over previous
into a Windows Metafile graphic (WMF) may fix some versions of FireWorks 1.60 software.
performance issues.

© 24APR12 UTC Fire & Security. All rights reserved. 1/2 P/N 3101872-EN • REV 3.0 • ISS 24APR12
Upgrading FireWorks 1.50 and earlier
FireWorks 1.70 will not install over FireWorks 1.50 and earlier. If
you plan to use the same computer, you must first uninstall the
previous version of FireWorks and all of its components, and
then install FireWorks 1.70.
FireWorks 1.50 projects are compatible with FireWorks 1.70.
FireWorks 1.41 and earlier projects are not compatible. To import
a FireWorks 1.41 and earlier project into FireWorks 1.70 you
must first convert it to a FireWorks 1.50 project.

To upgrade FireWorks 1.50 and earlier:


1. Convert your project to 1.50 if it is from a previous version.
2. Verify and repair your FireWorks project until the utility
returns a message that verification was completed without
any issues.
3. Back up your FireWorks database to a safe location.
4. Using Add or Remove Programs in the Windows Control
Panel, uninstall the following programs:
• The previous version of FireWorks and, if prompted,
previous versions of Crystal Reports
• Microsoft SQL Server Desktop Engine
• FireWorks Remote Web Server, if installed.
5. Remove Internet Information Server (IIS), if installed.
Click Add/Remove Windows Components, and then clear
the Internet Information Server (IIS) check box.
6. Delete the C:\Program Files\Microsoft SQL Server folder.
7. Rename the C:\Fireworks folder. For example,
C:\FireWorks_old.
8. Restart the computer.
9. Install FireWorks 1.70.
Start FireWorks System Builder and restore your migrated
FireWorks 1.50 database (File > Restore a 1.5x version project).

Upgrading a previous version of FireWorks Web


Client to 1.7x
The Web Client installation program recognizes that a previous
version of Web Client is loaded and suggests removing it.
Previous versions of FireWorks Web Client may reside on the
same computer as FireWorks Web Client 1.7x, if necessary. For
example, if you are using one remote computer to monitor
multiple FireWorks installations and each installation uses a
different version of FireWorks.
Commands on the Start menu no longer refer to GE; they were
renamed to Edwards Software (Start > All Programs > Edwards
Software).
Web Client 1.50 is not compatible with FireWorks 1.70. If
FireWorks is upgraded to version 1.7x then you must also
upgrade all Web Clients to version 1.7x.

2/2 P/N 3101872-EN • REV 3.0 • ISS 24APR12