Professional Documents
Culture Documents
3001175.rev1.fleischer - FEH Hygenic Master PDF
3001175.rev1.fleischer - FEH Hygenic Master PDF
Fleischer Zimbabwe
11 Neil Avenue
Msasa
Zimbabwe
Fax:263 4 446 098
date: 23/11/2010
Dear Sir.
We thank you for your enquiry and take pleasure in submitting our quotation for your
perusal as follows:
Index
Page -1-
SECTION(A)
COMMERCIAL CONDITIONS
Page -2-
SECTION (B)
Technical details
Pos. 100
HygienicMaster FEH321 Electromagnetic Flowmeter system, remote mount,
sensor housing stainless steel
Code Quantity Unit Price Total Price
[ZAR] [ZAR]
FEH321.050.P.1.A.1.F1.E.0.A.1.A.2.A.1.A.0.Y.1. 1 20,823.96 20,823.96
AY......M5
Complete with:
FET321.1.A.0.A.1.A.1.B.1
FEH321
- Bore Diameter 050 DN 50 (2 in.)
- Liner Material P PFA
- Electrode Design 1 Standard
- Measuring Electrodes Material A Stainless steel 904 (1.4539)
- Grounding Accessories 1 Standard
- Process Connection Type F1 Food industry fittings acc. DIN 11851
- Process Connection Material E 316L (1.4404) stainless steel with EPDM gasket
- Usage Certifications 0 Meter tube with PED certificate (Pressure
Equipment Directive)
- Calibration Type A Standard factory calibration - Without
ScanMaster
- Temperature Range of Installation / 1 Standard design / -20 ... 60 °C (-4 ... 140 °F)
Ambient Temperature Range
- Name Plate A Adhesive label
- Signal Cable Length and Type 2 10 m (30 ft) standard cable
- Explosion Protection Certification A Without
- Protection Class Transmitter / Protection 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X)
Class Sensor
- Cable Conduits A M20 x 1.5
- Power Supply 0 Without
- Input and Output Signal Type Y Without
- Configuration Type / Diagnostics Type 1 Parameters set to factory defaults / Standard
diagnostic functions activated
- Accessories AY Without
- Documentation Language M5 English
- Adjusted Maximum Measuring Range 1300 l/h
Page -3-
Complete with:
FET321 Electromagnetic Flowmeter, remote transmitter, for ProcessMaster / HygienicMaster
- Temperature Range of Installation / 1 Standard design / -20 ... 60 °C (-4 ... 140 °F)
Ambient Temperature Range
- Explosion Protection Certification A Without
- Power Supply 1 100 ... 230 V AC, 50 Hz
Page -4-
Pos. 200
HygienicMaster FEH321 Electromagnetic Flowmeter system, remote mount,
sensor housing stainless steel
Code Quantity Unit Price Total Price
[ZAR] [ZAR]
FEH321.050.P.1.A.1.F1.E.0.A.1.A.2.A.1.A.0.Y.1. 1 20,823.96 20,823.96
AY......M5
Complete with:
FET321.1.A.0.A.1.A.1.B.1
FEH321
- Bore Diameter 050 DN 50 (2 in.)
- Liner Material P PFA
- Electrode Design 1 Standard
- Measuring Electrodes Material A Stainless steel 904 (1.4539)
- Grounding Accessories 1 Standard
- Process Connection Type F1 Food industry fittings acc. DIN 11851
- Process Connection Material E 316L (1.4404) stainless steel with EPDM gasket
- Usage Certifications 0 Meter tube with PED certificate (Pressure
Equipment Directive)
- Calibration Type A Standard factory calibration - Without
ScanMaster
- Temperature Range of Installation / 1 Standard design / -20 ... 60 °C (-4 ... 140 °F)
Ambient Temperature Range
- Name Plate A Adhesive label
- Signal Cable Length and Type 2 10 m (30 ft) standard cable
- Explosion Protection Certification A Without
- Protection Class Transmitter / Protection 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X)
Class Sensor
- Cable Conduits A M20 x 1.5
- Power Supply 0 Without
- Input and Output Signal Type Y Without
- Configuration Type / Diagnostics Type 1 Parameters set to factory defaults / Standard
diagnostic functions activated
- Accessories AY Without
- Documentation Language M5 English
- Adjusted Maximum Measuring Range 1800 l/h
Complete with:
FET321 Electromagnetic Flowmeter, remote transmitter, for ProcessMaster / HygienicMaster
Page -5-
- Temperature Range of Installation / 1 Standard design / -20 ... 60 °C (-4 ... 140 °F)
Ambient Temperature Range
- Explosion Protection Certification A Without
- Power Supply 1 100 ... 230 V AC, 50 Hz
Page -6-
Pos. 300
HygienicMaster FEH321 Electromagnetic Flowmeter system, remote mount,
sensor housing stainless steel
Code Quantity Unit Price Total Price
[ZAR] [ZAR]
FEH321.050.P.1.A.1.F1.E.0.A.1.A.2.A.1.A.0.Y.1. 1 20,823.96 20,823.96
AY......M5
Complete with:
FET321.1.A.0.A.1.A.1.B.1
FEH321
- Bore Diameter 050 DN 50 (2 in.)
- Liner Material P PFA
- Electrode Design 1 Standard
- Measuring Electrodes Material A Stainless steel 904 (1.4539)
- Grounding Accessories 1 Standard
- Process Connection Type F1 Food industry fittings acc. DIN 11851
- Process Connection Material E 316L (1.4404) stainless steel with EPDM gasket
- Usage Certifications 0 Meter tube with PED certificate (Pressure
Equipment Directive)
- Calibration Type A Standard factory calibration - Without
ScanMaster
- Temperature Range of Installation / 1 Standard design / -20 ... 60 °C (-4 ... 140 °F)
Ambient Temperature Range
- Name Plate A Adhesive label
- Signal Cable Length and Type 2 10 m (30 ft) standard cable
- Explosion Protection Certification A Without
- Protection Class Transmitter / Protection 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X)
Class Sensor
- Cable Conduits A M20 x 1.5
- Power Supply 0 Without
- Input and Output Signal Type Y Without
- Configuration Type / Diagnostics Type 1 Parameters set to factory defaults / Standard
diagnostic functions activated
- Accessories AY Without
- Documentation Language M5 English
- Adjusted Maximum Measuring Range 1300 l/h
Complete with:
FET321 Electromagnetic Flowmeter, remote transmitter, for ProcessMaster / HygienicMaster
Page -7-
- Temperature Range of Installation / 1 Standard design / -20 ... 60 °C (-4 ... 140 °F)
Ambient Temperature Range
- Explosion Protection Certification A Without
- Power Supply 1 100 ... 230 V AC, 50 Hz
Page -8-