PENTALIGN ® pocket guide

The adjustable sliding bracket is Safety notes Get to know PENTALIGN


4 used to mount the PENTALIGN
base especially in applications
where the laser must not be  PENTALIGN is to be used in industrial environments only for
Components
moved. The base can be mounted
geometric measurements. Care must be taken to ensure that
either vertically [see image The main components are:
opposite] or horizontally. the instrument is not subjected to mechanical knocks. It must
be operated only by properly trained personnel. No liability
will be assumed when components or operating procedures as
PENTALIGN® 1

2
3
› PENTALIGN base
› PENTALIGN head
› PENTALIGN sensor
described in this guide are not used as indicated or are altered 4 › Adjustable sliding bracket
without permission of the manufacturer.
Pocket guide The PENTALIGN base has a small
1 circular mirror positioned at its
Laser safety centre. The mirror is used to
centre the laser beam [refer to first
adjustment step].

 Do not look directly into the laser beam at any time. (Since
FDA specifications allow maximum exposure of 0.25 seconds,
the natural blink reaction of the human eye would normally
PENTALIGN fine adjustment knobs be sufficient to avert any danger, provided that no optical
instruments other than ordinary eye glasses or contact lenses
are used. But as natural blink reaction may fail to occur, care
The bottom of the base houses
should be taken to avoid staring into the beam.)
three powerful magnets which
 Do not insert any optical devices into the beam path. 2 allow easy and good fixation to
magnetic surfaces. Additionally,

Contents subject to change without further notice, particularly in the interest of further technical development.
E D
the base may be attached to
Notes regarding data storage an adapter plate which can be
mounted on to a construction
 PRÜFTECHNIK assumes no responsibility, directly or indirectly,
tripod.
C for financial losses or claims from third parties resulting from
the use of this product and any of its functions, such as loss or
alteration of stored data.
B

The PENTALIGN head houses the


3
pentaprism and is attached to the
base with the two screws on its
A Contact top.
The PENTALIGN sensor is attached
to the base using the two screws
Printed in Germany · DOC 6.101.11.11.en

PRÜFTECHNIK on its top. The black button is the


The image above shows the fine
On/Off switch which at the same
adjustment knobs for PENTALIGN. Alignment Systems GmbH
time is used for the set-up of the
The PENTALIGN head, housing the
Freisinger Str. 34 sensor. The four LEDs positioned at
pentaprism, has been mounted to
90º apart round the sensor guide
the base. 85737 Ismaning, Germany
the user during the offset fine
Knobs A and B are used for offset
Tel +49.89.99616-0 adjustment of the base. The sensor
adjustment.
is powered using a single ‘AAA’
Knobs C and D are used for Fax +49.89.99616-100
size battery which is housed at the
angular adjustment.
info@pruftechnik.com bottom of the sensor.
Knob E is used for the fine rotation
of the PENTALIGN head. www.pruftechnik.com

PENTALIGN_Pocket-guide_DOC 06.101_en.indd 2-4 09.11.2011 16:07:38


Verkürzung FALZ FALZ FALZ Verkürzung

PENTALIGN® pocket guide

Mounting options for PENTALIGN ii. Adjust the laser beam as for a straightness measurement. At the vi. With the laser beam now iv. Take first point by pressing
nearest position, make adjustments by moving the tripod in the striking the centre of the the ON/OFF button briefly.
Depending on the kind of measurement being carried out, there are horizontal and vertical planes. For the farthest position, rotate PENTALIGN base, mount There will be a one second
several ways to mount the system. the turret to adjust the laser beam angle using the LEVALIGN the PENTALIGN target cap wait before the point is
 Tripod micrometer screws for fine adjustment. For details, please refer ALI 6.926 on the turret taken. The LEDs flash red in
› Use the adapter plate ALI 6.924 to fix the PENTALIGN base to the operating instruction manuals for the flatness and straight- position (see image). a circular sequence.
to the tripod. ness applications – ALI 9.847.G and ALI 9.848.G respectively. vii. The reflected beam from v. Rotate the sensor through
 Magnetic base iii. Now remove the laser assembly head [turret] by undoing the two the PENTALIGN base must 180° using the 45° markings
› Position the PENTALIGN base on the magnetic surface. The screws on its top. LEVALIGN laser now shoots a beam which is now strike the centre of the on the PENTALIGN base as
three powerful magnets on the bottom of the base ensure 90º to the original beam with turret mounted. target cap. Use the PENTALIGN angular fine adjustment knobs [C reference, then press the
rigid mounting. iv. Mount PENTALIGN vertically on the adjustable sliding bracket, and D ] to achieve this. ON/OFF button briefly to take the second point. After a one-
 Adjustable sliding bracket beside the other guide/rail. The base of the sliding bracket viii.Mount the PENTALIGN head then rotate it to ensure the laser second wait, the second point is taken.
› This bracket allows mounting PENTALIGN in the horizontal should be almost parallel to the guide/rail to be measured. beam strikes the first and last measurement positions of the vi. When interpreting the LEDs, always consider oppositely posi-
as well as in the vertical direction. The bracket can also be v. Take off the PENTALIGN head. Aim the LEVALIGN laser beam second guide/rail. If this is achieved, the system is now ready to tioned LEDs together.
mounted directly onto a tripod. at the round mirror in the take measurements. If one of two oppositely positioned LEDs is blinking red, the laser
centre of the PENTALIGN is more than 1 mm away from the mid-position. Move the sensor
Set-up base. This is achieved by In the above example – measuring the parallelism of two guides/rails towards the red blinking LED. One of the LEDs will start blinking
moving the tripod for the – the LEVALIGN laser beam should first strike the sensor on the first green fast when the laser strikes at a distance less than 1 mm
Usage of PENTALIGN sensor is dependent on the type of measure- rough adjustment, and guide/rail. When the turret is removed, the laser beam strikes the from the mid-position. If an LED is blinking green slowly, the laser
ment being performed. the LEVALIGN micrometer PENTALIGN head, and is emitted parallel to the initial beam [with is less than 50 μm away from the mid-position.
screws for the fine adjust- the turret mounted]. The two parallel guides/rails are measured vii. If all LEDs are blinking green slowly and you want to measure
Measurements WITHOUT PENTALIGN sensor ment. As LEVALIGN has using the ROTALIGN Ultra straightness application and analysed as more precisely proceed with steps viii and ix described below.
already been adjusted in groups using ALIGNMENT CENTER PC software. For details, please Precise mode
 Perpendicularity measurement between guides/rails using the first guide/rail, an iterative adjustment procedure is followed refer to respective operating instructions. viii.Press the ON/OFF button briefly to take the third point. There will
ROTALIGN, LEVALIGN or Long Range lasers and the ‘Right until LEVALIGN is positioned to shoot the laser beam parallel to be a one second wait then the LEDs will flash red in a circular
Angle Check’ firmware on ROTALIGN Ultra the guide/rail [when turret is on] and straight into the circular Measurements WITH PENTALIGN sensor sequence.
› Note that LEVALIGN laser can be used without PENTALIGN to mirror at the centre of the PENTALIGN base [with turret off]. This ix. Rotate the sensor through 180° using the 45° markings on the
carry out right angle check measurement. step ensures that PENTALIGN deviates the laser beam accurately All applications where the PENTALIGN head must be rotated for PENTALIGN base as reference, then press the ON/OFF button
 Measurement of vertical parallelism of guides/rails using parallel to the beam emitted when the turret is mounted. measurement require the use of the PENTALIGN sensor to minimize briefly to take the fourth point. If the laser strikes the sensor
LEVALIGN laser any offset errors. These measurement tasks include measurement of detector at a distance less than 50 μm from the mid-position, the
› Note that horizontal parallelism of guides/rails is determined perpendicularity between a guide rail and a surface, parallelism of corresponding LED will blink green slowly. If the laser beam is less
by an independent flatness measurement. two surfaces and flatness measurement. than 10 μm from mid-position, the corresponding LED lights up
steady green. If all four LEDs light up steady green, the laser is
How to carry out mirror adjustment How to set up and use the PENTALIGN sensor less than 7.5 μm away from the mid-position.
If measuring parallelism between guides/rails, Follow this step-by-step procedure in order to centre the laser beam x. The system is now ready to take measurements.
an initial adjustment of PENTALIGN to the on PENTALIGN. This operation minimizes any offset error that may To turn off the sensor, press and hold the ON/OFF button. All the
incoming laser beam from LEVALIGN laser is affect accuracy. LEDs will flash for a short time signalling shutdown. Release the
required. i. Mount the sensor on the PENTALIGN base. button. The sensor automatically shuts down after five minutes.
Follow this step-by-step procedure to measure ii. Switch the sensor on by pressing and holding the black ON/OFF
parallelism of guides/rails. button until one LED lights up green. Dismount the sensor from the PENTALIGN base then mount the
i. Set up LEVALIGN laser in a vertical position. iii. If the laser beam strikes the sensor detector, all four LEDs will PENTALIGN head. If the first surface has already been measured using
[Use the PRÜFTECHNIK tripod and the flash green. If the laser fails to strike the detector, the LEDs flash LEVALIGN laser, remove the turret. The laser beam should strike the
supplied base (see image) – ALI 6.956.] red. PENTALIGN head. The second surface can now be measured.

PENTALIGN_Pocket-guide_DOC 06.101_en.indd 6-8 09.11.2011 16:07:46

You might also like