Professional Documents
Culture Documents
3 Brochure l Contactors
Contactors I Page 2
Page 3 I Contactors
The quality of a switching device is not least revealed when switching off.
Between the opening contacts arcs are generated - as in a thundercloud.
To extinguish these arcs, we have fitted our contactors with sophisticated
solutions: Within a few milliseconds the arc is deflected by a magnetic field
and reliably blown into the arc chute. There it is lengthened, cooled, and
quenched.
With many years of experience in railway engineering, we develop reliable
contactors for power supply systems, data processing centers, and electric
vehicles.
Specifications :: Contactors
Series ► C100 C130 C137 ... C165 C400, C600 C152 ... C159 C160, C162 C193 C195
700 V ... 1,000 V --- --- --- --- C155, C156, C157 C162 C195 A, C195 B
Main contacts
Number of 1 1 1 1 1*3, 2 ... 4 1 1 1
Configuration or *2 or *4 or
Auxiliary contacts
Number of 1 1 1 1 1 ... 4 1 ... 6 1 2 max.
Configuration
Mechanical endurance > 3million cycles > 3 million cycles > 3 million cycles > 10,000 cycles 2 million cycles 5 million cycles 5 million cycles > 3 million cycles
can c can c
you you
RoHS
ou
ou
Quality
Quality
nt on
nt on
2011/65/EC
Sc Sc
h a lt b a u h a lt b a u
Emergency disconnect switches, Cam switch elements, Terminal bolts, Fuse holders :: Specifications
S100/80 S132 S134 S135 S005, S007, S008 S306, S307, S310 EKS127 SH-1P ... SH-3P ◄ Series
--- --- --- --- --- --- --- Single terminal bolts
Main contacts
1 1 1 1 or 2 1 1 Number of
--- 1, 2, 3 pole Configuration
Auxiliary contacts
1 Number of
--- --- --- --- --- --- --- Configuration
Contactors for:
--- --- --- --- Industry
--- --- --- --- Energy
Material Handling
--- --- --- --- Transportation Technology
100,000 cycles 30,000 cycles 30,000 cycles 30,000 cycles > 1 million cycles > 2 million cycles --- --- Mechanical endurance
Contactors :: Specifications
CA1315/02, CH500, CH800, CT1000/04,
C294 C295 CL1000 CH715, CH815 CU1215/06 ◄ Series
CA1315/04 CH801, CH1030 CT1000/08
DC DC / AC DC / AC AC (f ≤ 400 Hz) DC / AC DC / AC DC DC / AC Type of voltage
Main contacts
2 2 1 ... 3 3 1 1 2 1 ... 2 Number of
Configuration
Auxiliary contacts
1 2 2 4 max. 1 2*5 max. 4 max. 4 max. Number of
or or or Configuration
--- --- --- --- --- --- --- Bistable/latching version
Suitable for:
--- Industry
--- --- --- --- Energy
--- --- --- --- --- --- --- --- Material Handling
--- Transportation Technology
> 3 million cycles > 3 million cycles > 3 million cycles > 250,000 cycles 1 million cycles 1 million cycles 2 million cycles > 2 million cycles Mechanical endurance
Battery contactors to meet the requirements of industrial trucks Combination contactors for battery voltages
C100 Series contactors are the easy and economical solution for switching Schaltbau's competitively-priced all-in-one device is a combination of line
DC currents of 60 A up to 320 A as well as battery voltages up to 80 V. contactor, main fuse and manual cut-off switch in which additional devices
The contactors are equipped with DC coils featuring coil tolerances as re- as well as an optional horn can be integrated.
quired for traction batteries of industrial trucks and other battery-powered Main field of application are battery powered warehouse machines, such
vehicles. as fork lift and reach trucks as well as walk behind trucks and stackers.
Features
■■ Compact, rugged design ■■ Compact design
■■ Type of 4 different sizes ■■ Emergency disconnect switch with rugged, spring-loaded snap mechanism
■■ Double-break cadmium-free contacts ■■ Battery contactor with main fuse
■■ Extra wide coil tolerance ■■ Permanent magnetic blowout
■■ Standards: IEC 60947, EN 1175-1 ■■ Double-break contacts, cadmium-free
■■ Optional auxiliary switch and ■■ Optional horn and fuses
mounting brackets
Specifications
Series ► C100/80 – C100/120 – C100/200 – C100/320 C130/180 – C130/250
Type of voltage DC DC
Main contacts
Number of, Configuration 1x SPST-NO 1x SPST-NO
Nominal voltage Un 80 V 80 V
Rated insulation voltage Ui 150 V 150 V
Rated impulse withstand voltage Uimp 2.5 kV 2.5 kV
Pollution degree PD3 PD3
Overvoltage category OV3 OV3
Conventional thermal current Ith 60 A – 100 A – 150 A – 250 A 120 A – 250 A
Auxiliary contacts
Number of, Configuration 1x SPDT, optional 1x SPDT, optional
Suitable for:
Industrial applications – Battery voltages – Battery voltages
Railway applications --- ---
Coil voltage Us 24 / 48 V DC 24 / 48 V DC
Page 7 I Contactors
Features
■■ Compact design ■■ Single pole DC NO contactors for 400 A and 600 A resp. used as main con-
■■ Double-break contacts tactors in emergency installation (UPS) and as deep discharge protection
for batteries
■■ Easy to replace main contacts
■■ Compact design
■■ Blowout magnets
■■ Easy to mount
■■ 2 coil versions:
■■ Cadmium-free
for industrial applications,
coil tolerance -30 % ... +10 % ■■ Nominal coil power < 15 W
for railway applications, ■■ Standard make with 1 auxiliary
coil tolerance -30 % ... +25 % contact available
Specifications
C137 – C163 – C164 – C165 C400 – C600 ◄ Series
DC, AC DC Type of voltage
Main contacts
1x SPST-NO or 1x SPDT 1x SPST-NO Number of, Configuration
110 V 96 V Nominal voltage Un
160 V 125 V Rated insulation voltage Ui
2.5 kV No data Rated impulse withstand voltage Uimp
PD3 PD3 Pollution degree
OV3 OV3 Overvoltage category
50/40 A* – 100/80 A* – 140 A – 220 A 400 A – 600 A Conventional thermal current Ith
Auxiliary contacts
1x SPDT, optional 1x SPDT Number of, Configuration
Suitable for:
– Battery voltages – Battery voltages Industrial applications
– Battery voltages --- Railway applications
24 / 36 / 48 / 72 / 80 / 110 V DC 24 / 36 / 48 / 72 / 80 / 110 V DC Coil voltage Us
* Conventional thermal current Ith at Ta = 40°C / Ta = 70°C
Contactors I Page 8
Features
■■ Rugged design ■■ Double-break contacts, cadmium-free ■■ Slim, robust design
■■ Various combinations of switching ■■ Various combinations of 6 auxiliary ■■ Solid contacts
elements (4 main / 4 auxiliary max.) switches max. ■■ Series S306, S307, S310 featuring
■■ Easy to replace switching elements ■■ Easy to replace switching elements double-break contacts
■■ Double-break contacts ■■ Coil tolerance -30% ... +25% ■■ Available with electromagnetic or
■■ Coil tolerance -30% ... +25% permanent-magnetic blowout
■■ Coil economy circuit ■■ Optional arc chamber for
Series S306, S307, S310
■■ Parallel connection: 800 A max.
■■ Long life
■■ Easy to mount and replace
Specifications
Series ► C152 ... C159 C160 – C162 S005 – S007 – S008 / S306 – S307 – S310
Type of voltage DC, AC DC, AC DC, AC
Main contacts
Number of, Configuration 1x /2x / 3x / 4x SPST-NO or SPST-NC 1x SPST-NO 1x SPST-NC
Nominal voltage Un 450 V or 750 V 450 V or 750 V 400V / 450 V
Rated insulation voltage Ui 630 V or 1,000 V 630 V or 1,000 V 400 V max. / 1,000 V max.
Rated impulse withstand voltage Uimp No data No data No data
Pollution degree PD3 PD3 PD3
Overvoltage category OV3 OV3 OV3
Conventional thermal current Ith 160 A – 200 A – 250 A – 300 A – 500 A 160 A – 200 A – 250 A 15 A – 25 A – 60 A / 160 A – 300 A – 500 A
Auxiliary contacts
Number of, Configuration 4 max., optional 6 max., optional ---
Suitable for:
Industrial applications – Voltages ≤1,000 V – Voltages ≤1,000 V – Voltages ≤400 V / ≤1.000 V
Railway applications – Auxiliaries / Air-cond. / Motor – Auxiliaries / Air-conditioning – Voltages ≤400 V / ≤1.000 V
Coil voltage Us 12 / 24 / 48 / 60 / 80 / 96 / 110 / 220 V DC 12 / 24 / 48 / 60 / 80 / 96 / 110 V DC ---
Page 9 I Contactors
Compact single pole NO contactors for voltages Compact single pole contactors
up to 1,000 V for voltages up to 1,200 V
Single pole high-voltage contactor of compact design: Notwithstanding Being of compact size and featuring double-break contacts that are
its small size, the C193 Series contactor features an extraordinary switching covered for the most part, the C195 Series contactors provide high-
capacity for DC applications up to 1,000 V. performance current breaking. Their high contact force improves electrical
Best suited for the harsh environment of public transport, the C193 has performance and reliability even under harsh ambient conditions.
proven to be a transportation system component of high reliability which There is also the option of a SPDT version of the C195 which has an added
has an electrical life that is above average. galvanically isolated NC contact.
Features
■■ Very compact design ■■ Suitable for years of continuous duty
■■ Suitable for years of continuous duty ■■ Intended for high ambient temperatures
■■ Intended for high ambient temperatures ■■ Double-break contacts
■■ Double-break contacts ■■ Versions for AC and DC operation
■■ Versions for AC and DC operation ■■ DC versions with magnetic blowout
■■ DC versions with blowout magnets
■■ DIN rail mount option
Specifications
C193 C195 ◄ Series
DC, AC DC, AC Type of voltage
Main contacts
1x NO 1x NO or 1x SPDT Number of, Configuration
750 V NO: 1,200 V / SPDT: 200 V Nominal voltage Un
1,000 V NO :1,600 V / SPDT: 630 V Rated insulation voltage Ui
4 kV 6 kV Rated impulse withstand voltage Uimp
PD3 PD3 Pollution degree
OV3 OV3 Overvoltage category
50 A 250 A Conventional thermal current Ith
Auxiliary contacts
1x SPDT, optional 2x SPDT, optional Number of, Configuration
Suitable for:
– Voltages ≤1,000 V – Battery voltages / Voltages ≤1,000 V Industrial applications
– Auxiliaries / Air-conditioning – Battery voltages / Auxiliaries / Air-conditioning Railway applications
24 / 36 / 48 / 72 / 80 / 110 V DC 24 / 36 / 48 / 72 / 80 / 110 V DC Coil voltage Us
Contactors I Page 10
Features
■■ Very compact design ■■ Compact, rugged design
■■ Suitable for years of continuous duty ■■ Double-break contacts
■■ Intended for high ambient temperatures ■■ DC versions with magnetic blowout
■■ Double-break contacts ■■ Higher switching capacity resulting from main contacts connected in series
■■ DC versions with magnetic blowout ■■ Parallel connection results in longer electrical life
Specifications
Series ► C294 C295 A / ...B – C295 K / ...L – C295 S / ...T
Type of voltage DC DC, AC
Main contacts
Number of, Configuration 2x SPST-NO 2x SPST-NO
Nominal voltage Un 1,000 V 750 V – 1,200 V – 200 V
Rated insulation voltage Ui 1,200 V 1,000 V – 1,600 V – 1,000 V
Rated impulse withstand voltage Uimp 8 kV 8 kV – 10 kV – 8 kV
Pollution degree PD3 PD3
Overvoltage category OV3 OV3
Conventional thermal current Ith 40 A 120 A
Auxiliary contacts
Number of, Configuration 1x SPDT, optional 2x SPDT, optional
Suitable for:
Industrial applications – Voltages ≤1,000 V – Voltages ≤1,000 V
Railway applications – Auxiliaries / Air-conditioning – Auxiliaries / Air-conditioning
Coil voltage Us 24 / 36 / 72 / 110 V DC 24 / 36 / 48 / 60 / 72 / 96 / 110 V DC
Page 11 I Contactors
Features
■■ 1, 2 and 3 pole versions ■■ Innovative design: compact, rugged, reliable
■■ Double-break NO contact ■■ High short-circuit breaking capacity for frequencies up to 400 Hz
■■ Versions for AC and DC operation ■■ 3 pole version
■■ DC versions with magnetic blowout ■■ Double-break contacts
■■ Compact, rugged design ■■ Easy maintenance
■■ Drives with coil tolerances according to railway standard ■■ Drive with coil tolerance according to railway standard
■■ Low maintenance and long life ■■ Standard: EN 60077
Specifications
CL1115/02 – CL1215/02 – CL1315/02 CA1315/02** – CA1315/04 ◄ Series
DC, AC AC (f ≤ 400 Hz) Type of voltage
Main contacts
1x, 2x, 3x SPST-NO 3x SPST-NO Number of, Configuration
1,500 V 1,500 V Nominal voltage Un
2,200 V 2,000 V Rated insulation voltage Ui
12 kV 15 kV Rated impulse withstand voltage Uimp
PD3 PD3 Pollution degree
OV3 OV3 Overvoltage category
250 A / 200 A* 250 A – 350 A (540 A***) Conventional thermal current Ith
Auxiliary contacts
2x SPDT, optional 4x SPDT max. Number of, Configuration
Suitable for:
– High voltages >1,000 V --- Industrial applications
– Auxiliaries / Air-conditioning/ Traction inverters – Motor Railway applications
24 / 72 / 110 V DC 24 / 72 / 110 V DC Coil voltage Us
* Conventional thermal current Ith at Ta = 40°C / Ta = 70°C ** Series in development *** Special design
Contactors I Page 12
Features
■■ Compact design ■■ Compact design
■■ Double-break contacts ■■ Double-break contacts
■■ Coil tolerance: -30% .... +25% ■■ Coil tolerance: -30% .... +25%
■■ Designed for nominal loads of 16 kW AC / DC ■■ Designed for nominal loads of 50 kW AC / DC
■■ Range of applications: ■■ Range of applications:
Load switching in power supply systems Load switching in power supply systems
Main and control contactor for air- Main and control contactor for air-
conditioning and heating systems conditioning and heating systems
Specifications
Series ► CH715 – CH815 CH500 – CH800 – CH801 – CH1030
Type of voltage DC, AC DC, AC
Main contacts
Number of, Configuration 1x SPST-NO 1x SPST-NO
Nominal voltage Un 3.0 kV DC / 1.5 kV AC 3.0 kV DC / 1.5 kV AC
Rated insulation voltage Ui 3.0 kV 5 kV
Rated impulse withstand voltage Uimp 15 kV 25 kV
Pollution degree PD3 PD3
Overvoltage category OV3 OV3
Conventional thermal current Ith 50 A CH500 ... CH801: 80 A / CH1030: 120 A
Auxiliary contacts
Number of, Configuration 1x SPDT, optional 2x SPDT, optional
Suitable for:
Industrial applications – High voltages >1,000 V – High voltages >1,000 V
Railway applications – Auxiliaries / Air-conditioning – Auxiliaries / Air-conditioning
Coil voltage Us 24 / 110 / 120 V DC 24 / 72 / 110 / 120 V DC
Page 13 I Contactors
Series CT1x15/04 ... CT1x30/04,
Series CU1215/06
CT1x15/08 ... CT1x30/08
Double pole DC power contactors for power supply Power contactors for AC and DC
and UPS systems
With the double pole contactors CU1215/06 Schaltbau is expanding its Owing to a new blowout technology, CT1000 contactors can be used in
product range of new and innovative switching devices ranging up to almost any AC or DC railroad network. It also ensures a very low-wear and
performance class 600 A. reliable switching behaviour wherever the contactor is used, even under
The CU series power contactors are especially designed for central invert- very difficult switching conditions.
ers of PV installations and wind turbines as well as power supply and UPS Different styles for 1.5 kV and 3 kV allow for the optimal adaptation of
systems. CT1000 contactors to global railway applications.
The contactors guarantee reliable, low-wear switching of high loads. The
double-coil drive reduces efficiently power consumption in continuous
operation.
Features
■■ Double-break NO contacts ■■ Combination of permanent-magnetic and
■■ Unidirectional power contactor for: electromagnetic blowout
Power supply and UPS systems ■■ Compact, rugged design
Photovoltaic installations ■■ 2 different switching capacities
■■ Compact, rugged design ■■ Double-break contacts, cadmium-free
■■ 2 different switching capacities ■■ 1 and 2 pole versions
■■ Double coil requires less holding power ■■ Extended coil tolerance according to railway standard,
no economy circuit necessary
■■ Low maintenance
■■ Standard: IEC 60077
■■ Long life
■■ Standards IEC 60947, UL60947
Specifications
CU1215/06 CT1x15/04 ... CT1x30/04 – CT1x15/08 ... CT1x30/08 ◄ Series
DC (unidirectional) DC, AC Type of voltage
Main contacts
2x SPST-NO 1x, 2x SPST-NO Number of, Configuration
1,500 V 1.5 kV – 3.0 kV Nominal voltage Un
2,300 V 3 kV – 4.8 kV Rated insulation voltage Ui
12 kV 15 kV – 25 kV Rated impulse withstand voltage Uimp
PD3 PD3 Pollution degree
OV3 OV3 Overvoltage category
600 A 400 A – 800 A Conventional thermal current Ith
Auxiliary contacts
1x NC, 1x NO, 2x SPDT 1x NC, 1x NO, 2x SPDT Number of, Configuration
Suitable for:
– High voltages >1,000 V – High voltages >1,000 V Industrial applications
--- – Traction inverters Railway applications
24 / 110 V DC 24 / 110 V DC Coil voltage Us
Contactors I Page 14
Low-voltage terminal bolts Fuse holders for strip fuses Emergency disconnect switches for
to DIN43560 up to 48 V or battery voltages
Single terminal bolts of Schaltbau are easily in- Fuse holders for strip fuses to DIN 43560 are Schaltbau S100 Series emergency disconnect
corporated in devices for the purpose of electri- designed for use in battery powered vehicles switches guarantee instantaneous cut-out by
cal termination. They are designed for currents covering voltages up to 80 V. Fuse ratings may manual operation.
and voltages applicable to materials handling range from 50 A to 425 A. Load circuits are closed by pulling the red knob
and rail vehicle equipment. The EKS127 Series We offer fuse holders admitting 1, 2 or 3 strip and, in an emergency, forcibly ruptured by
terminal bolts can be used as individual termi- fuses. Tie bars for 2 or 3 poles are available. pushing it down. The positive opening opera-
nals or mounted onto a rail to form a terminal Copper sheet tie bars are available for our 2 and tion guarantees that the contacts open in the
block. They are often used as insulated mount- 3 pole fuse holders. event of an emergency.
ing support for switching elements or in other Special feature: The knob can be used as key.
electrical components. When engaged to the OFF position it can be
removed so as to prevent unauthorized use of
the truck.
Features
■■ Four different sizes available ■■ Fuse holders suitable for fuse links to DIN 43560 ■■ Single pole emergency disconnect switch with
■■ Mounted with 2 M4 screws ■■ 1-, 2- or 3-pole styles snap mechanism
■■ Option for rail mounting, ■■ Bases from heat-proof duroplast ■■ Key function: Knob removable in
fixed with split ring OFF position
■■ Hex screws, nuts and washers from
■■ Rugged design nickel-plated bars ■■ Maintained position for ON and OFF
■■ Base flame retardant to UL 94 V-0 ■■ Optional tie bars ■■ High resistance to shock and vibration
■■ Optional auxiliary switch
Specifications
Series ► EKS127 SH1-P – SH2-P – SH3-P S100/80
Type of voltage DC, AC DC, AC DC
Main contacts
Number of, Configuration --- --- 1x SPST-NC
Nominal voltage Un 80 V 80 V 24 / 36 / 48 V
Rated insulation voltage Ui 800 V / 900 V 630 V 150 V
Rated impulse withstand voltage Uimp No data No data 2.5 kV
Pollution degree PD3 PD3 PD3
Overvoltage category OV3 OV3 OV3
Conventional thermal current Ith No data for strip fuses 50 A ... 425 A 60 A
Auxiliary contacts
Number of, Configuration --- --- ---
Suitable for:
Industrial applications – Voltages ≤1,000 V – Battery voltages – Battery voltages
Railway applications – Voltages ≤1,000 V --- ---
Coil voltage Us 24 / 48 V DC 24 / 36 / 48 / 72 / 80 / 110 V DC ---
Page 15 I Contactors
Emergency disconnect switches for Emergency disconnect switches for Emergency disconnect switches for
up to 100 V or battery voltages up to 100 V or battery voltages up to 440 V or battery voltages
Manually operated emergency disconnect Installation of emergency disconnect switches Emergency stop switches are required for many
switches are capable of interrupting a power enhances safety at the work place significantly industrial machines and vehicles (meeting
circuit (meeting requirements of accident pre- (meeting requirements for accident preven- requirements for accident prevention). There are
vention). Single pole S132 Series switches are tion). Single pole S134 switches are especially single and double pole versions of S135 Series
especially designed for DC applications. designed for DC applications. switches.
Load circuits are closed by pulling the red mush Thanks to its snap mechanism the switch once Optional is a lockable version complete with
room knob and ruptered by pushing it down. actuated will complete the switch-off procedure cylinder lock. The disconnect switch may be
The positive opening operation guarantees that in any case, because the snap mechanism works locked when engaged to the OFF position so as
the contacts open in the event of an emergency. independently of the actuator. For ON and OFF to prevent unauthorized use - with key remov-
there are two maintained positions. able only in OFF position.
Features
■■ Single pole emergency disconnect switch with ■■ Single pole emergency disconnect switch with ■■ Single and double pole emergency disconnect
snap mechanism snap mechanism switch with snap mechanism
■■ Magnetic blowout ■■ Magnetic blowout ■■ Magnetic blowout
■■ Two definite maintained positions (ON/OFF) ■■ Two definite maintained positions (ON/OFF) ■■ Two definite maintained positions (ON/OFF)
■■ Optional lockable version ■■ Optional lockable version ■■ Optional lockable version
■■ Optional auxiliary contact ■■ Easy to replace cam switch elements
Specifications
S132 S134 S135 ◄ Series
DC DC, AC DC Type of voltage
Main contacts
1x SPST-NC 1x SPST-NC 1x or 2x SPST-NC Number of, Configuration
100 V 100 V 300 V Nominal voltage Un
160 V 160 V 600 V Rated insulation voltage Ui
2.5 kV 2.5 kV 6 kV Rated impulse withstand voltage Uimp
PD3 PD3 PD3 Pollution degree
OV3 OV3 OV3 Overvoltage category
125 A 250 A 160 A or 250 A Conventional thermal current Ith
Auxiliary contacts
--- 1x SPDT, optional 1x SPDT, optional Number of, Configuration
Suitable for:
– Battery voltages – Battery voltages – Battery voltages Industrial applications
--- --- --- Railway applications
--- --- --- Coil voltage Us
Schaltbau GmbH
For detailed information on our products
and services visit our website –
or give us a call!
Schaltbau GmbH
Hollerithstrasse 5
81829 Munich with compliments:
Germany