You are on page 1of 52

PRODUCT CATALOGUE

Fire Detection Solutions


HOCHIKI OFFICES AROUND THE WORLD
(from West to East)

HOCHIKI AMERICA CORPORATION


E: sales@hochiki.com
www.hochiki.com

HOCHIKI MEXICO
E: jbravo@hochiki.com
www.hochikiamerica.com

HOCHIKI EUROPE (UK) LTD


E: info@hochikieurope.com
www.hochikieurope.com

HOCHIKI ITALIA
E: info@hochiki.it
www.hochiki.it

HOCHIKI MIDDLE EAST FZE


E: sales@hochiki.ae
www.hochiki.ae

HOCHIKI EUROPE - INDIA BRANCH OFFICE


E: info@hochiki.in
www.hochikieurope.com/india

HOCHIKI ASIA PACIFIC


E: sales@hochikiasiapacific.com
www.hochikiasiapacific.com

HOCHIKI CORPORATION - TAIWAN BRANCH OFFICE


E: htro@hochiki.com.tw
www.hochiki.com.tw

HOCHIKI CORPORATION
E: overseas@hochiki.co.jp
www.hochiki.co.jp

HOCHIKI AUSTRALIA
E: sales@hochikiaustralia.com Hochiki Offices
www.hochikiaustralia.com

2
World Class Leaders
in Fire Detection Since 1918
Introduction Research and Development for Life Safety
Hochiki has a distinguished heritage of specialist technological expertise which has Hochiki owns the world’s largest, purpose-built, state of the art fire test laboratory.
gained the group its international status as one of the world’s leading manufacturers of This ensures that the pedigree of Hochiki products remains unrivalled and guarantees that
commercial and industrial fire detection solutions. Established early in the twentieth even large scale designs are fully proven in real fire conditions.
century, Hochiki has remained an independent, multi-national company which now
employs over 1500 personnel in total, operating five manufacturing plants, thirty-one In addition, the Group employs over 100 specialist research and development engineers
sales offices and eighteen subsidiaries. that undertake activities from fundamental research into the physical properties of fire,
to hardware and software product design and development.
Hochiki Europe (UK) Ltd manufactures and distributes product for Europe, the Middle East,
CIS, Indian Sub-Continent and Africa and is dedicated to providing sales and technical
services to these markets.

World Proven Performance


With a heritage of innovative design and leading edge technologies, Hochiki’s products
have gained widespread acceptance as the benchmark for high-integrity and long-term
reliability throughout the world.

3
Delivery Quality Useful Contact Information
Acknowledged globally by system specifiers and integrators as an international Hochiki Europe (UK) Limited
market leader in the manufacture of fire products, the main benefits of using Hochiki Grosvenor Road
devices are: Gillingham Business Park
ff High quality of products ensure long term reliability Gillingham
ff Easy to install Kent
ff Open Protocol for choice and flexibility ME8 0SA
ff Reduced cost of ownership United Kingdom
ff Virtual elimination of false alarms www.hochikieurope.com
ff Compliance to standards
@HochikiEurope
facebook.com/hochikieurope
Types of Fire Detection System
youtube.com/user/hochikieurope
Hochiki offers many types of fire detection system; this includes the ESP intelligent
linkedin.com/company/hochiki-europe-limited
analogue addressable fire alarm system, the CDX conventional system and FIREwave,
a hybrid wired/wireless system These ranges are supplemented by a large selection
of ancillary and test equipment. Main Switchboard
+44 (0)1634 266561
Product Colour Key +44 (0)1634 266562
Some products are available in a range of colours, and where appropriate, a colour
swatch is shown next to these products denoting which colours are available.
For example denotes product available in ivory. Supply Chain
+44 (0)1634 266561
Ivory White Black Grey Red Blue Green Yellow
+44 (0)1634 266562
sales@hochikieurope.com (UK-based enquiries)
export@hochikieurope.com (non-UK-based enquiries)

Technical Support
+44 (0)1634 266565
+44 (0)1634 266586
+44 (0)1634 266588
+44 (0)1634 266589
psupport@hochikieurope.com

4
ESPintelligent FIRElink
Analogue Addressable Fire Detection Air Sampling System
Sensors 7 FIRElink Detectors 35
Bases 9 FIRElink Accessories 36
Beams 9
Audio/Visual 9 ANCILLARY
Modules 12 Equipment
Manual Call Points 14
Ancillaries 38
Test Equipment 39
CDXconventional Power Supplies 41
Conventional Fire Detection Enclosures 41
Detectors 17
Beam Detectors 19 BEACON VARIANTS
Bases 19 Guides to our EN54-23 A/V Range
Audio/Visual 21
Sounder Beacons 44
Manual Call Points 24
Conventional Beacons 45
LINEAR Ceiling Beacons 46

HEAT Detection Wall Beacons 47

Interfaces 27
Cables 27

FIREwave
Hybrid Wireless Detection
FIREwave Translator & Expander 29
FIREwave Modules 30
FIREwave Manual Call Points 30
FIREwave Sensors 31
FIREwave Audio/Visual 31

5
ESP
intelligent
Analogue Addressable Fire Detection
Hochiki’s comprehensive ESP intelligent (Analogue Addressable
range) is suitable for even the most demanding environments and
incorporates high performance sensors, a wide selection of input
and output modules and ancillaries. All products use Hochiki’s
high integrity digital communications link ‘ESP’ (Enhanced Systems
Protocol) that’s at the heart of the ESP range.

www.hochikieurope.com/esp
ALN-EN ACC-EN ATJ-EN ACD-EN*
An Intelligent Photoelectric Smoke Sensor An Intelligent Multi Sensor incorporating a An Intelligent Multi-Heat Sensor incorporating Addressable Multi Sensor with CO detection
incorporating Hochiki’s unique High thermal element and a High Performance a variable Fixed Temperature heat element An addressable loop-powered multi-sensor,
Performance Chamber which allows the photoelectric smoke chamber. Has three and Rate Of Rise heat element, both with smoke, heat and CO sensing elements.
sensor threshold level to be increased, modes controlled from the Control Panel, controlled from the Control Panel allowing The unit offers 24 different modes of
thereby improving the signal to noise ratio allowing either the optical or thermal either thermal element or both elements operation* and seamlessly matches the other
and reducing susceptibility to false alarms. element or both to be active in making the simultaneously to be active in making the sensors in the ESP Range. The CO sensing
ff Removable, High Performance Chamber fire decision. fire decision. element can be used to detect smoke as
ff User selectable modes ff User selectable modes well as life-threatening CO levels (acting as a
ff Twin fire LEDs allow 360° viewing
CO alarm).
ff Locking mechanism (sensor to base) ff Incorporates Optical & Heat elements ff Incorporates Fixed Temperature and
ff Variable sensitivity ff Removable, High Performance Chamber Rate Of Rise Heat elements ff User selectable modes
ff Electronically addressed ff Twin fire LEDs allow 360° viewing ff Twin fire LEDs allow 360° viewing ff Low profile
ff Pulsing/non-pulsing controlled from panel* ff Pulsing/non-pulsing controlled from panel* ff Pulsing/non-pulsing controlled from panel* ff Twin fire LEDs allow 360° viewing
ff Addressed via TCH-B200 Hand Held ff Variable sensitivity ff Electronically addressed ff Multiple modes
Programmer ff Electronically addressed ff Addressed via TCH-B200 Hand Held ff Heat, Optical and CO sensing elements
ff Approved by LPCB, VdS & to SIL2 ff Addressed via TCH-B200 Hand Held Programmer ff CO Alarm (COHb) facility
ff Also available with an integrated SCI. Programmer ff LPCB & VdS approved to Classes A, B & C ff 10 year CO sensor life
ff Approved by LPCB, VdS & to SIL2 ff Approved to SIL2 ff Programmable fire threshold level
ff Also available with an integrated SCI. ff Also available with an integrated SCI. ff RI & LED controllable separately if required
ff 2 colour LED (Polling: Green, Fire: RED)
ff Addressed via TCH-B200 Hand Held
Programmer.

*Please ensure control panel compatibility 7


SCI SENSOR VARIANTS

ALN-EN(SCI) ACC-EN(SCI) ATJ-EN(SCI) YBV-R/4


An Intelligent Photoelectric Smoke Sensor An Intelligent Multi Sensor with SCI which is An Intelligent Multi-Heat Sensor with SCI SCI Sensor Mounting Base which is fully
with SCI incorporating Hochiki’s newest High fully compatible with Hochiki’s ESP Analogue which is fully compatible with Hochiki’s ESP compatible with Hochiki’s ESP range of
Performance Chamber Technology removing Addressable Protocol, and incorporates a Analogue Addressable Protocol. SCI sensors. It is supplied with square
the need to use Ionisation Smoke Sensors in thermal element and a High Performance The ATJ-EN(SCI) incorporates a Variable cable clamps for secure and reliable cable
the majority of applications. This also allows photoelectric smoke chamber. Temperature heat element and a Rate termination and is also capable of driving a
the sensor threshold level to be increased, The ACC-EN(SCI) has three modes, which are of Rise heat element, both of which are remote LED if required.
thereby improving the signal to noise ratio controlled from the Control Panel, allowing controlled from the Control Panel, allowing ff Electronics free
and reducing susceptibility to false alarms. either the optical element or thermal element either thermal element or both elements ff Stainless steel contacts
ff Removable, High Performance Chamber or both elements to be active in making the simultaneously to be active in making the fire ff Takes 2.5 mm2 cables
ff Twin LEDs allow 360° viewing – green when
fire decision*. decision. ff Slim profile - only 8 mm
polling, amber when isolating, red in fire ff User selectable modes ff User selectable modes ff Rugged wiring contacts
ff Locking mechanism (sensor to base) ff Incorporates Optical & Heat elements ff Incorporates Fixed Temperature and Rate of ff Facility for remote indicator
ff Variable sensitivity ff Removable, High Performance Chamber Rise Heat elements ff Quick Connection via square cable clamps
ff Pulsing/non-pulsing controlled from panel* ff Pulsing/non-pulsing controlled from panel* ff Twin LEDs allow 360° viewing – green when ff Fourth terminal enables SCI functionality.
ff Electronically addressed via TCH-B200 Hand ff Twin LEDs allow 360° viewing – green when polling, amber when isolating, red in fire
Held Programmer. polling, amber when isolating, red in fire ff Pulsing/non-pulsing controlled from panel*
ff Variable sensitivity ff Electronically addressed via TCH-B200 Hand
ff Electronically addressed via TCH-B200 Hand Held Programmer.
Held Programmer.

8 *Please ensure control panel compatibility


ACB-EW YBN-R/3 FB-1 CHQ-WS2
An Intelligent IP67 Rated Waterproof A Common Mounting Base which is fully An Addressable Reflective Beam Smoke An Intelligent Loop-Powered Wall Sounder
Multi-Heat Sensor which can be used compatible with Hochiki’s ESP range of Detector designed to protect large open providing 8 volume levels and 51 tones with a
externally and is supplied with its own fixing sensors. Supplied with square cable clamps spaces, features separate detector and maximum output of up to 102 dB(A) (±2 dB(A))
base which is used to fix the sensor. Flying for secure and reliable cable termination controller. The detector unit incorporates a with low current consumption.
leads from the sensor connect directly to the and is also capable of driving a remote LED motorised head that can align itself during ff Loop Powered
loop via waterproof connectors. if required. commissioning. Additional reflector kits
ff Single Loop Address - addressed via the
ff User selectable modes (Red version for Sounders available - see below) enhance detection range.
TCH-B200 Hand Held Programmer
ff Incorporates Fixed Temperature and ff Electronics free ff Controlled and adjusted from ground level ff Variable Sound Output 90 ~ 102 dB(A)
Rate Of Rise Heat elements ff Stainless steel contacts utilising included controller (±2 dB(A)) output at 1 metre
ff Twin fire LEDs allow 360° viewing ff Takes 2.5mm2 cables ff 5-40m standard detection range ff Weatherproof Kit available
ff Pulsing/non-pulsing controlled from panel* ff Slim profile - only 8mm ff Extension kits available to enhance ff Auto-shutdown Mode available*
ff IP67 rated detection range up to 100m ff Approved by LPCB, VdS & to SIL2
ff Rugged wiring contacts
ff Supplied with fixing base ff Fully compatible with the Hochiki ESP ff 51 User-Selectable Tones
ff Facility for remote indicator
ff Electronically addressed via TCH-B200 Hand analogue addressable protocol (all tones EN54-3 compatible).
ff Quick Connection via square cable clamps
Held Programmer & PL-2 ff Addressed via TCH-B200 Hand Held
ff Sounder version available in either red or
ff LPCB & VdS approved to Classes A, B & C. Programmer & PL-3
white for use with CHQ-WS2 Wall Sounders or
ff Continually corrects itself against building
CHQ-WSB2 Wall Sounder Beacons - YBO-R/3
movement
and YBO-R/3(WHT).
ff Approved by VdS.

*Please ensure control panel compatibility. 9


CHQ-WSB2*2 YBO-R/3 CHQ-WPK YBO-BS
An Intelligent Loop-Powered Wall Sounder is a Sounder Mounting Base which is fully A Weatherproof Back Box and gasket set for An Intelligent Loop-Powered Base Sounder
Beacon as per the CHQ-WS2 but additionally compatible with Hochiki’s ESP range of the CHQ-WS2 Wall Sounder, CHQ-CB Ceiling providing 13 volume levels and 51 tones
featuring an integral beacon within the horn sensors and designed specifically for the Beacon, CHQ-WB Wall Beacon and CHQ-WSB2 with a maximum output of up to 98 dB(A)
which utilises high intensity LED technology. Hochiki range of wall sounders, the CHQ-WS2 Wall Sounder Beacon, increases the IP Rating (±2 dB(A)) with low current consumption.
As per CHQ-WS2 plus: Wall Sounder and the CHQ-WSB Wall Sounder of the Sounder to IP65 for external use. Compatible bases:
Beacon. ff Easy to install YBN-R/3 or YBN-R/3(SCI) Bases.
ff Variable flash frequency*1
It is supplied with square cable clamps for ff Increases sounder IP Rating from IP21 to ff Loop Powered
ff High Intensity LED technology
secure and reliable cable termination. IP65 (external use)
ff Independent control of Sounder and Beacon*1 ff Single Loop Address - addressed
ff Electronics free ff Increases beacon IP rating from IP21 to automatically by Control Panel or via the
ff Auto-shutdown Mode available - can be set
ff Stainless steel contacts IP33 (external use). TCH-B200 Hand Held Programmer
independently for sounder or beacon*1
ff Approved to EN54-23: 2010 - Category ‘O’ ff Takes 2.5 mm2 cables ff 50 ~ 98 dB(A) (±2 dB(A)) output at 1m
ff Addressed via TCH-B200 Hand Held ff Slim profile - only 13 mm ff Fits Hochiki Standard or Isolator Base and
Programmer. ff Rugged wiring contacts supports ESP Sensors, Beacons and
ff Quick Connection via square cable clamps Remote Indicator
ff Also available in white ff Approved by LPCB, VdS & to SIL2
ff Short Circuit Isolator version available - ff 51 User-Selectable Tones
YBO-R/SCI(RED) & YBO-R/SCI(WHT-SNDR). (all tones EN54-3 compatible).

10 *1Please ensure control panel compatibility. *2For product variants, see pages 44 to 47.
YBO-BSB2*2 CHQ-CB*2 CHQ-WB*2 CHQ-ARI
An Intelligent Loop-Powered Base Sounder An Intelligent Loop-Powered Ceiling Beacon An Intelligent Loop-Powered Wall Beacon with An Intelligent Loop-Powered Remote
Beacon providing 13 volume levels and with a high-intensity LED and a custom a high intensity LED and a custom designed Indicator, with high-intensity LEDs and a
51 tones with a maximum output of up designed free-form optic which produce a free-form optic which produces a highly Fresnel lens design which produces a highly
to 98 dB(A) (±2 dB(A)) with low current highly visible flash. Variants available in 5m, visible flash. Variants available in 5m, 7.5m visible signal. The casing exactly matches the
consumption. 7.5m, 10m and 15m area coverage. and 10m area coverage. Hochiki ESP Sensor range in shape and colour
Compatible bases: ff High Intensity LED technology Compatible bases: providing seamless integration.
YBN-R/3 or YBN-R/3(SCI) Bases. ff 0.5/1 Hz flash frequency YBN-R/3, YBN-R/3(SCI), YBO-BS or the ff High Intensity LED technology
ff Loop Powered ff Addressable via TCH-B200 YBO-R/(SCI). ff Addressable via TCH-B200
ff Single Loop Address, addressed by either ff Choice of 2 LED colours (red and white) ff High Intensity LED technology ff Approved by VdS
Control Panel or TCH-B200 ff Approved to EN54-23: 2010 - Category ‘C’ ff 0.5/1 Hz flash frequency ff Non EN54-23 Compliant.
ff 50 ~ 98 dB(A) (±2 dB(A)) output at 1m ff High efficiency ff Addressable via TCH-B200
ff Fits Hochiki Standard or Isolator Base and ff Selectable light output*1 ff Choice of 2 LED colours (red and white)
supports ESP Sensors, Beacons and ff Operating Voltage 17-41 VDC. ff Approved to EN54-23: 2010 - Category ‘W’
Remote Indicator ff High efficiency
ff Beacon and Sounder can be controlled ff Selectable light output*1
independently*1 ff Operating Voltage 17-41 VDC.
ff Approved to EN54-23: 2010 - Category ‘O’
ff 51 User-Selectable Tones
(all tones EN54-3 compatible).

*1Please ensure control panel compatibility. *2For product variants, see pages 44 to 47.
11
2x 1x 1x
Monitored Monitored
Input Output Input

CHQ-AB CHQ-POM CHQ-SIM CHQ-SOM


An Intelligent Loop-Powered Visual Indicator An Intelligent Powered Output Module An Intelligent Single Input Module designed An Intelligent Single Output Module designed
with high-intensity LEDs and Fresnel lens designed to supply a nominal 24 VDC at to allow a single monitored input to be to allow a single relay output to be connected
design which produces a highly visible flash. various, user-selectable current levels from connected to the ESP loop. This provides to the ESP loop. The unit incorporates a
The casing exactly matches the Hochiki ESP 2 to 32 mA (in increments of 2 mA). The a compact, low-cost option where the volt-free relay contact that can be configured
Sensor range in shape and colour providing unit is small enough to be added to other installation of the larger CHQ ‘Smart-Fix’ as either N/O or N/C, the relay contact is
seamless integration. third-party devices thereby allowing a range Range of Modules might be difficult. rated to 30 VDC (max), 1 A (resistive load).
ff High Intensity LED technology of equipment to be added to the ESP loop. ff Small design for simple provision of a The CHQ-SOM features three colour-coded
The unit also features two monitored inputs. monitored input onto an ESP loop flying leads, the unit also features a wiring
ff 1 Hz flash frequency
ff Supplies a nominal 24 VDC at various current terminal block for loop connection.
ff Addressable via TCH-B200 ff Flying leads for easy installation
ff Choice of 3 lens colours (red, amber and blue) levels, 2 mA to 32 mA in increments of 2 mA ff Addressed with TCH-B200 Hand Held ff Small design for simple provision of a
ff Approved by VdS (red and amber lens) ff User-selectable current output Programmer & PL-3 monitored input onto an ESP loop
ff Non EN54-23 Compliant ff Includes two monitored inputs ff Approved by LPCB & VdS. ff Flying leads for easy installation
ff Supplementary indicator. ff Approved by LPCB & VdS ff Approved by LPCB
ff Addressed with TCH-B200 Hand Held ff Addressed with TCH-B200 Hand Held
Programmer & PL-3 Programmer & PL-3.
ff Colour-coded flying leads for simple
installation
ff Small design, provides simple connectivity
to ESP loop for third-party devices, such
as IFD-E.

12
Lid Colours Lid Colours Lid Colours
1x 1x 1x 4x 4x
Monitored 2x
Transparent Input Output Transparent Monitored Transparent Input Output
Input Input Output
Black Black Black

Opaque Opaque Opaque


White White White

CHQ-MRC2 CHQ-DRC2(SCI) CHQ-PCM(SCI) CHQ-DIM2(SCI)


An Intelligent Mains Relay Controller An Intelligent Dual Relay Controller designed A Plant Control Module with four independent An Intelligent Dual Input Module designed to
providing a single mains rated relay to provide two general-purpose relay outputs, change-over relay outputs, with N/O and N/C interface to a variety of inputs such as door
output for the control of such devices as each output can be controlled independently volt free contacts and four inputs. These contacts, sprinkler flow/door switches and
dampers, extractors or plant and equipment and used to control dampers, plant and outputs can be driven separately by the plant equipment. Also available as a DIN Rail
shut-down. The monitored input can be used equipment shut-down. The monitored input fire alarm control panel and can be used for mountable version. Both models feature an
for local power supply fault monitoring or as can be used for local power supply fault the control of devices such as dampers or integral short-circuit isolator.
a general-purpose input. Also available as monitoring or as a general-purpose input. for plant and equipment shut-down. Also ff Loop powered
a DIN Rail mountable version. Both models Also available as a DIN Rail mountable available as a DIN Rail mountable version.
ff Single loop address
feature an integral short-circuit isolator. version. Both models feature an integral Both models feature an integral short-circuit
ff DIL switch addressable
ff 1 x mains out & 1 x input short-circuit isolator. isolator.
ff Each input can be configured to operate on
ff Loop-powered ff Loop powered ff 4 x inputs & 4x outputs either an open or short-circuit.
ff Single loop address ff Single loop address ff Single loop address ff Both models approved by LPCB & VdS
ff DIL switch addressable ff DIL switch addressable ff Loop powered ff Can be used with CHQ-BACKBOX to comply
ff Single mains rated relay contact ff Relays contact rated at 30 VDC at 1 A ff DIL switch addressable with BS 7671.
ff Relay contact rated at 250 VAC @ 5A ff Auxiliary monitored input ff 4 change-over relay outputs
(resistive) & 48 VDC @ 2A (resistive) ff Both models approved by LPCB & VdS ff 4 independent inputs for monitoring of
ff Auxiliary monitored input ff Deeper back box available CHQ-BACKBOX volt-free contacts
ff Both models approved by LPCB ff Two independently controlled changeover relays ff Both models approved by LPCB
ff Can be used with CHQ-BACKBOX to comply ff Can be used with CHQ-BACKBOX to comply with ff Deeper back box available CHQ-BACKBOX CHQ-DIM2/DIN(SCI)
with BS 7671. BS 7671. ff Can be used with CHQ-BACKBOX to comply
with BS 7671.
CHQ-MRC2/DIN(SCI) CHQ-DRC2/DIN(SCI) CHQ-PCM/DIN(SCI)
CHQ-PCM/DIN(SCI)

CHQ-DRC2/DIN(SCI)

13
Lid Colours Lid Colours Lid Colours
1x 2x
2x 1x Monitored
Transparent Zones Transparent Zone Transparent Sounder-
Black Black Black Input Output

Opaque Opaque Opaque


White White White

CHQ-DZM(SCI) CHQ-SZM2(SCI) CHQ-DSC2(SCI) HCP-E(SCI)


An Intelligent Dual Zone Module designed An Intelligent Single Zone Monitor designed An Intelligent Dual Sounder Controller which An Intelligent Manual Call Point Isolator fully
to allow up to 60 conventional detectors to allow up to 6 conventional detectors or has been designed to provide two sounder compatible with Hochiki’s ESP analogue
(30 per zone) or up to 6 SPC-ET (3 per zone) 1 SPC-ET to be interfaced to Hochiki’s ESP outputs (that can be driven separately) with addressable protocol and featuring an
to be interfaced to Hochiki’s ESP analogue analogue addressable system. Also available full fault monitoring. The monitored input integral short-circuit isolator (SCI). Features
addressable system. The unit also features as a DIN Rail mountable version. Both models can be used for local power supply fault a bi-coloured LED to indicate either fire (red)
Schottky and Zener line continuity options. feature an integral short-circuit isolator. monitoring or as a general-purpose input. or short-circuit (amber). Also features plug-in
Also available as a DIN Rail mountable ff 1 x zonal input
Also available as a DIN Rail mountable wiring terminals for easy installation.
version. Both models feature an integral version. Both models feature an integral ff Fast response
ff Loop powered
short-circuit isolator. short-circuit isolator.
ff Up to 6 Conventional Detectors ff Integral short-circuit isolator
ff 2 x zonal inputs ff DIL switch addressable ff Single loop address ff Bi-colour status LED
ff Single loop address ff Single loop address ff Two independent sounder circuits ff Non-frangible element fitted as standard
ff Supports two independent zones of ff Remote LED output ff DIL switch addressable (conforms to EN54)
conventional detectors ff Both models approved by LPCB & VdS ff Each circuit fully monitored for Open and ff Addressed with TCH-B200 Hand Held
ff DIL switch addressable Short Circuit faults Programmer & PL-3
ff Deeper back box available CHQ-BOX
ff Requires an auxiliary 24 VDC supply ff Each alarm circuit fused at 1 A ff Surface or flush mounting
ff Fully monitored for Open and Short
ff Both models approved by LPCB Circuit faults ff Auxiliary monitored Input ff LPCB Approved to EN54
ff Deeper back box available CHQ-BACKBOX ff Can be used with CHQ-BACKBOX to comply ff Outputs are synchronised and can be driven ff Approved to SIL2.
ff Both zones fully monitored for Open and with BS 7671. continuously or intermittently
short Circuit ff 24 VDC auxiliary power required
ff Can be used with CHQ-BACKBOX to comply ff Both models approved by LPCB & VdS
with BS 7671. ff Can be used with CHQ-BACKBOX to comply
with BS 7671.

CHQ-DIM2/DIN(SCI) CHQ-SZM2/DIN(SCI) CHQ-SZM2/DIN(SCI)

CHQ-DZM/DIN(SCI) CHQ-DZM/DIN(SCI) CHQ-DSC2/DIN(SCI) CHQ-DSC2/DIN(SCI)

14
HCP-W(SCI) SR BACKBOX PS200
TCH-B200
An Intelligent IP67 Weatherproof Manual Call Call Point Surface Mounting Box Hinged cover for Call Point. An acrylic hinged
A Hand Held Address Programmer designed
Point Isolator fully compatible with Hochiki’s for HCP-E(SCI) cover for the HCP-E(SCI) manual call point
to address the ESP range of Sensors and
ESP analogue addressable protocol and ff Allows addressable call point HCP-E to be range which protects against accidental
other intelligent devices such as the YBO-BS
featuring an integral short-circuit isolator surface mounted. operation/vandalism.
Base Sounder. Designed to be light, robust
(SCI). Features a bi-coloured LED to indicate ff Easy to install and easy to use it operates from a single
either fire (red) or short-circuit (amber). Also
ff Protects against accidental activation PP3 size battery which can provide up to
features plug-in wiring terminals for easy
ff Requirement under BS5839. 8000 operations.
installation.
ff Lightweight design
ff Fast response
ff Quick and reliable addressing
ff Integral short-circuit isolator
ff Up to 8000 address settings from
ff Bi-colour status LED
one battery
ff Non-frangible element fitted as standard
ff Displays sensor analogue value.
(conforms to EN54)
ff Addressed with TCH-B200 Hand Held
Programmer & PL-3 Note: Button colour may vary.
ff Surface mounting
ff LPCB Approved to EN54
ff IP67 rated
ff Approved to SIL2.

15
CDX
conventional
Conventional Fire Detection
Hochiki’s CDX range offers one of the most extensive product
portfolios available, providing solutions for most conventional fire
detection applications as well as security systems, due to its wide
operating voltage range (9.5~30 VDC).

www.hochikieurope.com/cdx
SOC-E3N DCD-AE3 DCD-CE3 DFJ-AE3
A Conventional Photoelectric Smoke Detector A Conventional Rate of Rise Heat Detector A Conventional Rate of Rise Heat Detector A Conventional 60°C Fixed Temperature Heat
which is fully compatible with the majority of incorporating a 60°C fixed temperature incorporating a 90°C fixed temperature Detector using a thermistor and linearising
existing Conventional systems. element. The thermistor and linearising element. The thermistor and linearising circuit to provide an accurate linear response
ff Removable, High Performance chamber circuit provide an accurate linear response circuit provide an accurate linear response Heat Detector. A third terminal provides
Heat Detector. A third terminal provides Heat Detector. A third terminal provides integral remote indicator output.
ff Automatic Sensitivity Window Verification
integral remote indicator output. integral remote indicator output. ff Electronic linear heat detection
(ASWV) – Drift Compensation Technology
ff Remote Indicator output ff Electronic linear heat detection ff Electronic linear heat detection ff Remote Indicator output
ff Wide voltage range (12 ~ 30 VDC) ff Remote Indicator output ff Remote Indicator output ff Wide voltage range (9.5 ~ 30 VDC)
ff Low profile design with one piece outer cover ff Wide voltage range (9.5 ~ 30 VDC) ff Wide voltage range (9.5 ~ 30 VDC) ff Twin fire LEDs allow 360° viewing
ff Single fire LED - 360° viewing ff Twin fire LEDs allow 360° viewing ff Twin fire LEDs allow 360° viewing ff Fixed Temperature Detector
ff Range of mounting bases ff Range of mounting bases ff Full range of mounting bases ff Full range of mounting bases
ff Approved by LPCB. ff Approved by LPCB & VdS. ff Approved by LPCB & VdS. ff Approved by LPCB & VdS.

17
DFJ-CE3 DFG-60BLKJ DRD-E IFD-E
A Conventional 90°C Fixed Temperature Heat An IP67 Waterproof Conventional 60°C A Conventional Flame Detector designed A Conventional IR3 Infrared Flame Detector
Detector using a thermistor and linearising Fixed Temperature Heat Detector with for internal use to detect large flames. The designed to respond to low-frequency (1 to
circuit to provide an accurate linear response. minimal standby current and high reliability. detector fits any of the CDX range of mounting 15Hz) flickering IR radiation emitted from
A third terminal provides integral remote Particularly suited to environments, which bases. The detection zone is a 90° cone and flames during combustion, the unit can
indicator output. are exposed to high levels of condensation or the detection range is up to and including discriminate between flames and spurious
ff Electronic linear heat detection are hosed down. 25m. sources of radiation such as sunlight. An I.S.
ff Waterproof design – rated to IP67 ff Class 1 performance as defined in version and an explosion-proof version are
ff Wide voltage range - can be installed on
also available.
security systems ff Low profile shape ff BS EN54-10:2002 (range up to 25m)
ff Twin fire LEDs allow 360° viewing ff Utilises a bi-metallic strip to sense ff Single IR technology ff Triple IR sensor
ff Fixed Temperature Detector temperature change ff Robust and slim design ff Class 1 sensitivity to EN54-10 detects
ff Full range of mounting bases ff No Mounting base required ff Low current consumption 0.1m2 fire @ 25m
ff Approved by LPCB & VdS. ff Minimal standby current ff Easy to install ff Excellent optical interference immunity
ff Approved by LPCB & VdS. ff Fits any of the CDX Range of mounting bases (solar blind)
ff Twin LEDs for 360° view ff Selectable output options - conventional
2-wire, 4-20 mA, latching or non-latching
ff Approved by LPCB & VdS.
relay contacts, fire/fault, pre-alarm
ff Selectable response speed
ff Optical self-test
ff Low power consumption
ff Approved by LPCB
ff SIL Capable.

18
16591 16091 SPC-ET YBN-R/6
A UV/Dual IR Flame Detector, Alloy Housing A Hand Held Flame Detector Tester providing a A Conventional Beam Smoke Detector that A Conventional Detector Mounting Base
Model 16591 is an IR2 flame detector with an flame-free method of UV testing the industrial consists of an emitter and receiver that cover associated with the CDX Range of Detectors
additional UV detection element, designed IR3 series of flame detectors: IFD-E, IFD-E(IS) a distance of 5 - 100m providing a maximum and Beacons and is fully compatible with the
for use where open flaming fires may be and the IFD-E(Exd). coverage of 1500m2. Features an automatic majority of existing conventional fire alarm
expected and responds to the light emitted signal strength adjustment facility and is also control panels.
from flames during combustion. ff Simple to use hand held unit with available with a latching or a non-latching
rechargeable NiCd battery pack and charger ff Integral remote indicator output
The detector discriminates between flames relay.
ff Tests many Flame Sensors Types UV, UV/IR, ff Low Profile, only 8mm
and other light sources by responding only ff 5 - 100m range ff Rugged design and electronics free
UV/IR2, IR3, IR2, IR
to particular optical wavelengths and flame ff Automatic compensation ff Quick connections via square cable clamps
ff Range typically 3m and beyond
flicker frequencies. This enables the detector ff Automatic signal strength adjustment ff Accepts up to 2.5mm2 cables
ff Selectable optical output intensity with LED
to avoid false alarms due to such factors as ff Can be interfaced onto ESP system via
bar graph indication ff Bayonet slot, low insertion force for detectors.
flickering sunlight. CHQ-DZM(SCI) or CHQ-SZM2(SCI)
ff Flame-free UV testing, ideal for hazardous
ff Highest immunity to false sources areas. ff Approved by LPCB & VdS
ff Suitable for indoor and outdoor areas ff Emitter unit can be powered direct from
ff Detects invisible flames from fuels such as THIS EQUIPMENT IS ALSO AVAILABLE FOR HIRE. zone (or loop).
Hydrogen and other inorganic fuels Please contact your Sales Representative for
ff Selectable response speed further information.
ff Optical self-test
ff Low power consumption
ff Approved to EN54.

19
YBO-R/6PA YBO-R/6R YBO-R/6RN YBO-R/6RS
A Conventional Detector Mounting Base A Conventional Latching Relay Detector A Conventional Non-Latching Relay Detector A Conventional Latching Schottky Diode
for 2-Wire systems where detectors and Mounting Base associated with the CDX Mounting Base associated with the CDX Relay Detector Mounting Base associated
sounders are on same zone cables*. Range of Detectors and is fully compatible Range of Detectors and is fully compatible with the CDX Range of Detectors and is fully
ff Integral remote indicator output with the majority of existing conventional fire with the majority of existing conventional fire compatible with the majority of existing
alarm and security control panels. alarm and security control panels. conventional fire alarm control panels.
ff Rugged design
ff Dedicated cable screen terminal ff Integral remote indicator output ff Integral remote indicator output ff Integral remote indicator output
ff Quick connection via square cable clamps ff Rugged design ff Wide voltage range - can be used in ff In-line Schottky Diode for Line Continuity
ff Accepts up to 2.5mm2 cables ff Quick connections via square cable clamps security systems ff Rugged design
ff Bayonet slot, low insertion force for detectors. ff Accepts up to 2.5mm2 cables ff Rugged design ff Quick connections via square cable clamps
ff Bayonet slot, low insertion force for detectors ff Quick connections via square cable clamps ff Accepts up to 2.5mm2 cables
ff Approved by LPCB ff Accepts up to 2.5mm2 cables ff Bayonet slot, low insertion force for detectors
ff Wide voltage range - can be used in ff Bayonet slot, low insertion force for detectors ff Approved by LPCB.
security systems. ff Approved by LPCB.

20 *Please ensure control panel compatibility.


YBN-R/6SK CSB-E CSBB-E CWSB-E
A Conventional Detector Mounting Base A Conventional Base Sounder which has A Conventional Base Sounder Beacon which A Conventional Wall Sounder Beacon with
with in-line Schottky Diode, associated been designed to complement the CDX range has been designed to complement the CDX improved electronic design enables very low
with the CDX Range of Detectors and is fully of detectors. Improved electronic design range of detectors. Improved electronic current consumption whilst providing a range
compatible with the majority of existing enables very low current consumption whilst design enables very low current consumption of tones and volumes selectable from each
conventional fire alarm control panels. providing a range of tones and volumes whilst providing a range of tones and volumes unit. Features integral beacon.
ff Integral remote indicator output selectable from each unit. selectable from each unit. Features integral ff Robust design
ff Robust design beacon.
ff In-line Schottky Diode for line continuity ff Low current consumption
ff Low profile, only 8mm ff Low current consumption ff Robust design ff Easy to install
ff Rugged design ff Easy to install ff Low current consumption ff Maximum 113 dB(A) @ 1m (Tone 15)
ff Quick connections via square cable clamps ff Maximum 93 dB(A) @ 1m (Tone 1) ff Easy to install ff 32 user-selectable tones
ff Accepts 2.5mm2 cables ff 32 user-selectable tones and ff Maximum 93 dB(A) @ 1m (Tone 1) ff Utilises high intensity LEDs
ff Bayonet slot, low insertion force for detectors. 3 user-selectable volumes ff 32 user-selectable tones and ff Supplementary indicator
ff Lockable cap available (CS/CAP). 3 user-selectable volumes ff Non EN54-23 compliant.
ff Utilises high intensity LEDs
ff Lockable cap available (CS/CAP)
ff Supplementary indicator
ff Non EN54-23 compliant.

21
BANSHEE EXCEL BANSHEE EXCEL IP66 BANSHEE EXCEL LITE BANSHEE EXCEL LITE IP66
An Electronic Conventional Sounder which An Electronic Conventional Sounder comes An Electronic Conventional Sounder Beacon An Electronic Conventional Sounder Beacon
can be installed internally. with a deeper IP66 back box, which enables which can be installed internally. comes with a deeper IP66 back box, which
ff Robust design the unit to be installed externally. ff Robust design enables the unit to be installed externally.
ff Low current consumption ff Robust design ff Low current consumption ff Robust design
ff Easy to install ff Low current consumption ff Easy to install ff Low current consumption
ff Maximum 110 dB(A) at 1m (dependent on ff Easy to install ff Xenon beacon technology ff Easy to install
tone selected) ff Deep base provides IP66 protection ff Maximum 110 dB(A) at 1m (dependent on ff Xenon beacon technology
ff 32 user-selectable tones ff Maximum 110 dB(A) at 1m (dependent on tone selected) ff Deep base provides IP66 protection
ff Approved by VdS. tone selected) ff 32 user-selectable tones ff 32 user-selectable tones
ff 32 user-selectable tones ff Approved by VdS ff Approved by VdS
ff Approved by VdS. ff Supplementary indicator ff Supplementary indicator
ff Non EN54-23 compliant. ff Non EN54-23 compliant
ff Maximum 110 dB(A) at 1m (dependent on
tone selected).

22
CLB-E CWST-S5 CWST-W5 MBF-6EV
A Conventional Visual Indicator for use on A Conventional Beacon which features A Conventional Weatherproof Beacon, which A Conventional Alarm Bell six inches diameter
24 V Sounder Circuits. The unit is fitted with high output LEDs, advanced optics and an features high output LEDs, advanced optics and for internal use, based upon the industry
a Fresnel lens and high-intensity LEDs, a innovative lens design, providing outstanding and an innovative lens design, providing standard KOBELL range.
design which produces a highly visible flash. Omni-directional light coverage at low current outstanding Omni-directional light coverage ff Low profile
The casing exactly matches the CDX Detector draw. Specifically designed for, and approved at low current draw. Specifically designed
ff Low current consumption
range in shape and colour providing seamless to meet EN54-23. CWST-S5 delivers quality, for, and approved to meet EN54-23.
ff Fully suppressed and polarised
integration. reliability and long operational life. Weatherproof base provides IP65 for external
ff 95 dB(A) at 1m (typ)
ff High Intensity LED technology ff Approved to EN54-23, C & W categories* use applications.
ff Approved by LPCB
ff Fits standard CDX base (YBN-R/6) ff Advanced optics ensures superior light ff Approved to EN54-23, C & W categories*
ff Simple installation with multi-fixing base plate.
ff Supplementary indicator coverage at low current draw ff Available in either red or white casings
ff Not EN54-23 compliant ff Available in either red or white casings ff Available with either a red or white LED
ff Colour-matched to existing detector and ff Available with either a red or white LED ff Synchronised flash exceeds EN54-23 standard
base ranges. ff Synchronised flash exceeds EN54-23 standard ff Soft start feature reduces power surges
ff Soft start feature reduces power surges during system start-up
during system start-up. ff Advanced optics ensures superior light
coverage at low current draw.

*For product variants, see pages 50 to 53.


23
FB/024/R/W CCP-E CCP-W CCP-SAVWIRE
A Conventional Alarm Bell six inches A Conventional Manual Call Point based An IP67 Conventional Weatherproof Call Point Conventional Savwire Call Point Red based
diameter, which has the same operation as upon the industry standard KAC world series which can be used externally. upon the industry standard KAC world
the MBF-6EV except it comes equipped with a housing. The unit can support either a ff Approved to EN54-11:2001 series housing and features easy to install,
weatherproof back box enabling it to be used ‘Frangible Glass’ element or a ‘Non Frangible push-fit wiring terminals. The unit has been
ff Supplied with back-box as standard
externally. Plastic’ element. It is also supplied complete specifically designed for use on “Savwire”
ff Other colours available on request
ff Low profile with SR-BACKBOX for surface mounting. (two-wire) systems.
ff Ingress Protection rated to IP67
ff Low current consumption Note - Yellow version not EN54 compliant ff Approved by LPCB The unit can support either a ‘Frangible Glass’
ff Fully suppressed and polarised element or a ‘Non Frangible Plastic’ element.
ff Approved to EN54-11:2001 ff Terminals can accommodate up to a 2.5mm2
ff 100 dB(A) at 1m (typ) solid conductor.
ff Other colours available on request ff Approved to EN54-11:2001
ff Weatherproof for external installation
ff Approved by LPCB ff Terminals can accommodate up to a 2.5mm2
ff Approved by LPCB solid conductor
ff Terminals can accommodate up to a 2.5mm2
ff Simple installation with multi-fixin base plate. ff Designed for use on “Savwire”

solid conductor.
(two-wire) systems*.

24 *Please ensure control panel compatibility.


CCP-KS
Conventional Key Switch Manual Call-Point
based upon the industry standard KAC 9000
series housing and features flying leads for
simple wiring.
The unit features two key positions marked as
“1” and “0” – with the key easily removable
in either position

ff Two position keyswitch (marked 1 and 0)


ff Key removable in both positions
ff Supplied with back box for surface fixing
ff Terminals can accommodate up to a 2.5mm2
solid conductor
ff Supplied in RED - other colours available
on request
ff Suitable for fire, security and other specialist
applications.

25
The Linear Heat Detection Cable (LHDC) System from Hochiki is
designed to provide early detection of fire and overheating in
circumstances where other forms of detection would not be viable,
either due to inability to sustain the environment requirements or
through prohibitive costs.

www.hochikieurope.com/lhdc
LDM-519-LP LHDC ANALOGUE CABLE LDM-519-DDL LHDC DIGITAL CABLE
Analogue LHDC Interface The module Analogue LHDC Heat Detection Cable is Digital Interface with Distance Display is Digital LHDC Heat Detection Cable is
is designed to monitor a zonal length designed to provide early detection of fire and designed to monitor a length of Digital Linear designed to provide early detection of fire
of Analogue Cable for both an elevated overheating in circumstances where other Heat Detection Cable (LHDC) for both a fire conditions and overheating in circumstances
temperature (Fire) condition, and Fault Status forms of detection would not be viable, either condition, and fault status (open circuit). where other forms of detection would not be
(Open & Short Circuit). due to inability to sustain the environment ff Test & Reset functions viable, either due to an inability to sustain
ff Adjustable Alarm set point requirements or through prohibitive costs. the environment requirements or through
ff Display of Alarm Location: Distance in metres
ff Adjustable Alarm set point prohibitive costs.
ff LED Indication of Fire, Fault and Supply Status ff Fault monitoring of LHDC for open circuit
ff Fault Monitoring for open & short circuits ff Recoverable and resettable operation conditions ff UL Listed
ff Selectable Latching / Auto reset operation ff Can detect hot spots ff LED Indication of Fire, Fault and Supply Status ff SIL 2 Certified
ff VFC outputs for Fire & Fault conditions ff Zones of up to 500m in length ff Operable from two wire fire panel ff Non-resettable cable
ff SIL 2 Certified ff Mechanical & Chemical protection available conventional circuits. Line / Low Power ff Early Detection of hazards at temperatures
ff 24 volt supply required when connected to ff Easy to install ff LHDC Hazardous Area use by means of well below flame point
an I/O unit ff RoHS compliant — Lead Free intrinsically Safe Zener Barriers. ff Rugged construction—Stainless Steel outer
ff Analogue address interface, Line powered ff Resettable cable ff Din Rail mounting sheath available
configurable ff Compatible with a full range of monitoring ff Analogue address loop interfacable - ff Fixed Alarm Trigger Temperature
ff Operable from two wire fire panel devices. Loop Powered configurable ff Compatible with many existing zone
trigger circuits. ff 4 to 20 mA instrumentation current monitors/ Control Equipment
loop output ff Intrinsically Safe Configurable for Hazardous
ff VFC outputs for Fire & Fault conditions - Areas.
Selectable.

*Other products available. Please speak to your regional sales manager or visit www.hochikieurope.com/lhdc for further details.
27
FIREwave
Hybrid Wireless Fire Detection

Hochiki’s FIREwave system raises wireless fire detection and alarm


systems to new levels of reliability and flexibility. The hybrid system
utilises the latest wireless technology to provide rapid, yet economic
wireless fire system installations with the minimum of disturbance
to the surroundings. Ideal for historic buildings, remote sites and
any project where the installation of fire cabling is difficult, overly
expensive or prohibited.

www.hochikieurope.com/firewave
SYSTEM ARCHITECTURE

RSM-WTM RSM-EXP
A Wire to Wireless Translator Module which A Wireless Expander Module which allows
allows a wireless fire detection system extended signal coverage for the wireless
to be interfaced directly onto the loop. system by boosting signal strengths from
Fully loop-powered, the unit can support translators, to cover larger buildings for
up to 32 wireless devices* and up to 7 example. Up to 7 RSM-EXP Expander
RSM-EXP Expander Modules**. Modules** can be supported by a single RSM-
ff Loop Powered WTM Wireless Translator Module.
ff Bi-directional wireless communication ff Bi-directional wireless communication
ff Automatic wireless channel hopping ff Automatic wireless channel hopping
ff Fully intelligent ff Fully intelligent
ff High reliability and sensitivity ff High reliability and sensitivity
ff Flexible on site device adjustment ff Flexible on site device adjustment
ff IP65 protection for exterior mounting ff IP65 protection for exterior mounting The RSM-WTM Translator Module (T) is fitted *Maximum number of 16 output devices such as
ff Makes additions to existing wired systems ff Makes additions to existing wired systems to the analogue addressable fire system loop. A/V or output modules.
easy and cost effective easy and cost effective It then provides an interface between the
loop and the wireless devices. The module is **Maximum of 5 child Expander Modules
ff LPCB approved ff Requires external power supply (24 VDC) connected in cascade or a maximum of 3 child
ff Self optimising wireless amplitude and ff LPCB approved fully powered by the loop and full control and
Expander Modules connected directly to the
frequency. ff Self optimising wireless amplitude and
monitoring of the wireless devices is possible Translator Module or another Expander Module
frequency.
through the control panel.

The RSM-EXP Expander Module (E) allows the


wireless system to provide greater coverage
by receiving and re-transmitting the boosted
wireless signal.

29
RSM-CIM RSM-IP RSM-POM RSM-CP
A Wireless Conventional Interface Module A Wireless Single Channel Input Module A Wireless Powered Output Module which A Wireless Resettable Manual Call Point
which allows a zone of wireless devices to which allows the on/off status (alarm/fault) allows the control panel to activate/switch which features a simulated glass front. When
be added to an existing conventional zone of an external device to be transmitted to the circuits of an external device or system activated, a plastic ‘flag’ is displayed in the
(or as a stand-alone zone). The zone is wired a control panel wirelessly via an RSM-CIM, wirelessly via an RSM-CIM, RSM-EXP or window of the unit; the supplied key will reset
directly to the RSM-CIM which is then in turn RSM-EXP or RSM-WTM. RSM-WTM. The unit’s contacts can be the flag and unit. Supplied with back box.
supported by an RSM-EXP Expander Module. ff Latching Input circuits are monitored for fire configured to be normally open or normally Weatherproof housing also available
ff Bi-directional wireless communication and fault conditions closed and switch at 30 VDC/125 VAC at 2 A. ff Bi Directional wireless communication
The unit can be configured to provide either a
ff Automatic wireless channel hopping ff Bi-directional wireless communication ff Fully intelligent
12 VDC or a 24 VDC output.
ff Fully intelligent ff Automatic wireless channel hopping ff Utilises standard low cost lithium
ff High reliability and sensitivity ff Fully intelligent ff Contacts can be configured as N/O or N/C battery technology
ff Flexible on site device adjustment ff High reliability and sensitivity ff Selectable output - 12 VDC or 24 VDC ff Long battery life
ff IP65 protection for exterior mounting ff Flexible on site device adjustment ff Bi-directional wireless communication ff Resettable Element
ff Makes additions to existing wired systems ff Makes additions to existing wired systems ff Automatic wireless channel hopping ff Clear ‘device activated’ warning flag
easy and cost effective easy and cost effective ff Fully intelligent ff High reliability
ff Requires external power supply for use as ff Self optimising wireless amplitude and ff High reliability and sensitivity ff Automatic channel hopping
stand-alone zone frequency. ff Flexible on site device adjustment ff Self optimising wireless amplitude and
ff Self optimising wireless amplitude and ff Makes additions to existing wired systems frequency.
frequency. easy and cost effective
ff Self optimising wireless amplitude
and frequency.

30
ROP-E RHT-E RMC-E HFC-SBR-23-03
A Wireless Dual Optical Smoke Detector A Wireless Class P Heat Detector designed for A Wireless Multi-Criteria Detector designed A Wireless Weatherproof Wall Sounder VAD
designed for open area protection and open area protection giving the best possible for open area protection and combines The HFC-SBR-23-03 Wall Sounder VAD forms
utilises dual-path optical smoke detection warning of a fire condition in locations where both dual-path smoke and heat detection the core of our wireless EN54-23 modular
technologies and algorithms for improved smoke detection technology is not suitable. technologies for improved performance, visual alarm device (VAD) range. The unit
performance, whilst maintaining the high The well-proven adaptive radio signal whilst maintaining the high levels of comes with a wireless module HFW-SIM-01
levels of unwanted alarm rejection. Utilising processing algorithms ensure the highest unwanted alarm rejection. Utilising well- which requires fitting into the Wall Sounder
wellproven adaptive radio signal processing levels of life safety and system reliability are proven adaptive radio signal processing VAD back box. The HFC-SBR-23-03 is weather
algorithms ensure the highest levels of life achieved. An in-built magnet test allows easy algorithms ensures that the highest levels of proof as standard and is equipped with 3
safety and system reliability are achieved. An activation to verify correct functionality and life safety and system reliability are achieved. levels of volume adjustment, high output LED
in-built magnet test allows easy activation to response. An in-built magnet test allows easy activation beacon and 32 recognised tones which can be
verify correct functionality and response. ff Twin alarm LEDs for 360 deg visibility to verify correct functionality and response. set locally at the sounder.
ff Advanced dual path optical chamber design ff Internal algorithm processing optimises ff Flexible modular design
ff Advanced dual path optical chamber design
ff Internal algorithm processing optimises performance ff Approved to EN54-3 and EN54-23 (W-2.5-7)
performance ff Internal algorithm processing optimises
ff 3rd party approved ff 32 Tone Settings
performance
ff 3rd party approved ff Utilises standard low cost lithium battery ff Two stage alarm capability
ff 3rd party approved
ff Up to 10 year battery life technology ff Weatherproof as standard
ff Utilises standard low cost lithium battery
ff Utilises standard low cost lithium battery ff Bi-directional wireless communications ff Easy to install
technology
technology ff Multiple sensitivity settings ff Can be configured as Beacon only
ff Multiple smoke and heat sensitivity setting
ff Bi-directional wireless communications ff Device identification tab. ff Microphone self test facility
ff Bi-directional wireless communications
ff Compatible with all FIREwave Translators ff Also available in White.
and Expanders ff Complies with the latest multi-sensor
standard EN 54-295 year product warranty
ff 5 year product warranty
ff Device identification tab
ff Device identification tab
ff Twin alarm LEDs for 360° visibility.
ff Dual angle scattering analysis
ff Fast test feature for engineer testing.

31
HFC-WSR-03 HFW-BS-05 HFW-BSB-05 HFW-DHR-01
Wireless Weatherproof Wall Sounder A Wireless Base Sounder unit is an A Wireless Base Sounder Beacon is an A wireless magnetic door holder
The HFC-WSR-03 Wall Sounder forms the core aesthetically pleasing and cost effective aesthetically pleasing and cost effective is compatible with all of the FIREwave
of our wireless EN54-3 modular alarm device alternative to traditional wall mounted alternative to traditional wall mounted units Wireless Translator and Expander Modules
range. The unit comes with a wireless module sounder units where visual impact is where visual impact is important. Each unit enabling it to be easily integrated into a new
HFW-SIM-01 which requires fitting into the important. Each unit has an integral moulded has an integral moulded base for mounting or existing wireless system, linked to any
Wall Sounder back box. The HFC-WSR-03 is base for mounting a FIREwave detector a FIREwave wireless detector (ROP-E, RMC-E, wired system or even used as a standalone
weather proof as standard and is equipped (ROP-E, RMC-E, RHT-E) or a sounder cover RHT-E) or a sounder cover if a detector is system. Its fully wireless and battery powered
with 3 levels of volume adjustment and 32 if a detector is not required. The unit has as not required. The unit has as standard 32 capability means it requires no wiring or
recognised tones which can be set locally at standard 32 recognised sounder tones and recognised sounder tones and 2 levels of power supply, making installation quick, easy
the sounder. 2 levels of volume adjustment, all of which volume adjustment, all of which can be easily and cost effective.
ff Flexible modular design can be easily configured on site. Powered configured on site. Additional to the audible
ff Approved to BS EN 1155
by standard lithium batteries and utilising warning the unit is also fitted with a Red LED
ff Approved to EN54-3 ff Easy and Fast installation
well proven adaptive radio signal processing visual indicator for added warning capability.
ff 32 Tone Settings ff Local door release button
algorithms ensure the highest levels of life Utilising well-proven adaptive radio signal
ff Two stage alarm capability ff 5 year battery life
safety and reliability. processing algorithms ensures the highest
ff Weatherproof as standard levels of life safety and reliability. ff Utilises standard low cost lithium battery
ff 2 volume levels
ff Easy to install technology
ff Approved to EN54-25 and EN54-03 ff 3rd party approval to EN54-25 and EN54-03
ff Microphone self test facility ff Bi-directional wireless communications
ff Bi-directional wireless communication ff Bi-directional wireless communication
ff Also available in white. ff A Fail Safe monitoring to BS 7273 - 4:2015
ff Utilises dual low cost standard lithium ff Utilises dual low cost standard lithium
cat. A, B & C
batteries batteries
ff High holding force
ff Choice of 32 recognised tones ff Choice of 32 recognised tones
ff A Door closed monitoring option.
ff Compatible with all FIREwave Translators ff Additional red LED visual indicator
and expanders ff 2 volume levels
ff Integral detector base ff Base adaptor available to allow older sensors
ff Base adaptor available to allow older sensors to be fitted to new sounder bases.
to be fitted to new sounder bases.

32
REPLACEMENT BATTERIES
Primary Battery
Spare Primary Battery (pack of 10)

Secondary Battery
Spare Secondary Battery (pack of 10)

33
FIRElink
Air Sampling System

Hochiki’s FIRElink range of high sensitivity air sampling equipment


consists of detectors and sampling pipe accessories to the very
highest levels of sensitivity in environments such as computer areas
and clean rooms. In these applications it is able to give warning to
the very slightest trace of smoke. All detectors in the FIRElink range
have been approved to EN54-20:2006 Classes A, B & C by LPCB.

www.hochikieurope.com/firelink
FIRElink-25 FIRElink-100 FIRElink-400 FIRElink-400CM
A Single Pipe Air Sampling Detector designed A Two Pipe Air Sampling Detector designed to A Four Pipe Air Sampling Detector A Four Pipe Air Sampling Detector with
to provide very high sensitivity smoke provide very high sensitivity smoke detection. designed to provide very high sensitivity integral Command Module designed to
detection. The unit will automatically setup The unit will automatically setup for easy smoke detection with inherent immunity to provide very high sensitivity smoke detection
for easy installation and is also designed installation and is also designed to fit into a dust/dirt build-up. Discriminates between with inherent immunity to dust/dirt build-up.
to fit into a Docking Station which accepts Docking Station which accepts all sampling ‘dirty’ and ‘clean’ operating periods such as Added “Command Module” allows the user to
all sampling pipes and cables leaving pipes and cables leaving the detector to be day and night, automatically substituting control, program and test other FIRElink units
the detector to be fitted during the final fitted during the final commissioning phase. appropriate system sensitivity without the on the same “network”.
commissioning phase. ff Approved LPCB need for external input or adjustment. ff Approved LPCB
ff Approved LPCB ff High sensitivity provided by laser based ff Approved LPCB ff High sensitivity provided by laser based
ff High sensitivity provided by laser based forward light scatter for reliable early warning ff High sensitivity provided by laser based forward light scatter for reliable early warning
forward light scatter for reliable early warning ff Two sampling pipes up to 100m (aggregate) forward light scatter for reliable early warning ff Four sampling pipes up to 200m (aggregate)
ff False alarms reduced by unique dust in length (still air) ff Four sampling pipes up to 200m (aggregate) in length (still air)
discrimination ff RS485 communications for networking and in length (still air) ff RS485 communications for networking and
ff RS485 communications for networking and remote communications ff RS485 communications for networking and remote communications
remote communications ff Ultra small, low cost aspirating smoke remote communications ff Command Module allows control over other
ff Ultra small, low cost aspirating smoke detector ff False alarms reduced by unique dust FIRElink units on network
detector ff False alarms reduced by unique dust discrimination. ff False alarms reduced by unique dust
ff Single sampling pipe up to 50m in length discrimination. discrimination.
(still air).

35
FL-RC FL-APIC FIRElink Sampling Pipes FIRElink Dust Filters
An Input Relay Card designed to provide An Addressable Protocol Interface Card The sampling pipe and connectors are FL-DF1 Hochiki Dust Filter For FIRElink 400
detector inputs that may be programmed used to decode and relay FIRElink detector used in conjunction with the FIRElink Series
for Remote Day/Night Mode Changeover, information directly to an Hochiki ESP Range of Air Sampling Detectors. The Pipe- FL-DF2 Hochiki Dust Filter For FIRElink 25/100
Remote Reset or ClassiFire Override as well as compliant Fire Control Panel. cad software supplied with each FIRElink Series
power supply fault monitoring. ff Full address range (1 - 127) detector calculates the length of pipe and
ff Relay contacts rated at 0.4 A @24 VDC configuration of sampling holes required for Prices and further details provided upon request.
ff Compatible with all FIRElink detectors and
each installation.
ff 4 staged normally open relay outputs for command modules
unmonitored connection to other systems ff Supports both single and multi mode Prices and further details provided upon request.
ff Common Fault relay energised normally operation.
closed for fail safe operation
ff Only compatible with FIRElink-25 and
FIRElink-100.

36
ANCILLARY
Equipment

Hochiki’s comprehensive range of ancillary equipment includes


products to help make routine maintenance and commissioning
of analogue and conventional smoke detectors easier and more
reliable. The range includes head removal tools, heat detector tester
poles, loop commissioning and emulation equipment and duct
smoke detection equipment.

37
DH-24 SDP-3 TCH-B200 16091
An Electromagnetic Door Holder designed to A Duct Probe Housing allowing a standard A Hand Held Address Programmer designed A Hand Held Flame Detector Tester providing a
hold open fire doors and is ideally suited for photoelectric smoke detection device, either to address the ESP range of Sensors and flame-free method of UV testing the industrial
hospitals, schools and other public buildings. a conventional detector or an analogue other intelligent devices such as the YBO-BS IR3 series of flame detectors: IFD-E, IFD-E(IS)
In a fire situation the doors can be released sensor, to be mounted on the outside of an Base Sounder. Designed to be light, robust and the IFD-E(Exd).
automatically via a connection to the fire air duct for the purpose of monitoring the air and easy to use it operates from a single
THIS EQUIPMENT IS ALSO AVAILABLE FOR HIRE.
alarm system or manually by activating the within the duct. PP3 size battery which can provide up to Please contact your Sales Representative for
release button. ff One-tube air sampling system 8000 operations. further information.
ff 24 VDC ff Test hole on cover ff Lightweight design ff Simple to use hand held unit with
ff Surface mounted ff Simple installation/maintenance ff Quick and reliable addressing rechargeable NiCd battery pack and charger
ff 200 Newton holding force ff Sensitive flow indication ff Up to 8000 address settings from one battery ff Tests many Flame Sensors Types UV, UV/IR,
ff Swivel keeper plate ff Installer-friendly connection of cables ff Displays sensor analogue value. UV/IR2, IR3, IR2, IR
ff Spring-loaded ejector pin ff Allows air duct sampling using standard ff Range typically 3m and beyond
ff Manual release button. detector or sensor Note: Button colour may vary. ff Selectable optical output intensity with LED
ff Fits either square or round section ducting bar graph indication
(with additional brackets). ff Flame-free UV testing, ideal for hazardous
areas.

38
YBN-UA YBD-RA SOLO POLES TESTIFIRE
A Recess Mounting Adaptor for both the ESP A Surface Wiring Adaptor which allows the Fibreglass Poles designed to be completely A fully portable field device for functional
and CDX Range of sensors and detectors and majority of Hochiki Sensors/ Detectors and interchangeable with all of the SOLO Tools. testing of fire detectors. The unit is
their associated mounting bases. Allows their Mounting Bases to be fitted flush against Manufactured in a lightweight fibreglass, suitable for testing optical/photoelectric
a base and head combination to be flush a fixing surface, whilst also allowing surface the poles are completely non-conductive and and ionisation smoke sensors, thermal
mounted by providing a recess fixing to the wiring (without conduit) to be connected. have been subjected to rigorous conductivity sensors (fixed temperature or rate-of-rise),
ceiling. ff Low profile - only 16mm testing to ensure the integrity of the and carbon monoxide (CO) fire sensors, be
insulating qualities. they conventional, addressable or analogue
(Shown with base fitted – not supplied) ff Compatible with the majority of existing
ff Lightweight, non conductive addressable.
Analogue and Conventional bases
ff Sturdy construction, easy to install ff Colour matches standard Hochiki Analogue ff Accept all of the SOLO tools ff Powered by battery batons within pole
ff Allows base and analogue sensor or and Conventional sensor/detector/ ff Can extend to 9m. ff Simultaneous stimuli (smoke and heat) can
conventional detector to be flush mounted base ranges. cut test times in multi-sensors by up to 66%
ff Supplied with fixing brackets ff Heat detector test times reduced through
ff Colour-matched to existing ivory-coloured wider range of settings
sensor/detector ranges ff Clearing cycle provides rapid detector reset
ff Suitable for a maximum ceiling thickness with no repeat alarm
of 30mm. ff Stimuli capsules for smoke and CO held
within unit
ff Faster, more productive testing with just
one tool.

39
SOLO 200 SOLO 330 SOLO 423/424 SOLO 461
A Universal Detector Removal Tool suitable for A Smoke Detector Tester providing functional A Heat Detector Tester mains-powered and A Cordless Heat Detector Tester which
the majority of current Hochiki detectors* testing to introduce (simulated) smoke or available in both 110/120 and 220/240 V utilises Cross Air Technology to ensure the
CO through the detector vents and into the versions. correct temperature is applied to the sensing
*Except those with flying leads, for example the
DFG-60E or the ACB-EW. sensing chamber. ff Initiates heat detectors into alarm, whether elements, not the detector plastics.
ff Robust, lightweight design rate of rise or fixed. ff Safe, cable free, battery-powered operation
ff Colour-coded grips twist into place to create
ff Touch sensitive, ideal for suspended ceilings ff Comes complete with a 5m lead as standard ff Supplied with 2 Battery BatonsTM and a
different size combinations
ff Clear cup allows view of detector LED (Optional 5m extension available). fast charger
ff Universal, counterbalanced joint ensures
ff Spring-loaded dispenser mechanism ff Intelligent device, only heats when detector
the tool remains horizontal.
conserves aerosol present.
ff Test gas canisters (non CFC) are available
containing either simulated smoke (for
testing smoke detectors) or CO (for testing
CO detectors).

40
SOLO 823 KIT HE-PSU(2.5A) HE-PSU(5.25A) SMB -1
A Universal Set Of Tools for testing and A Stand-Alone Power Supply Unit with A Stand-Alone Power Supply Unit with An IP66 Rated, Grey (RAL7035) Enclosure
removing smoke and heat detectors up to integrated charger designed to be used integrated charger designed to be used designed for use with the Hochiki range of
9m high. with Hochiki’s FIRElink range of air sampling with Hochiki’s FIRElink range of air sampling Modules. Supplied with a transparent black
detectors and the CHQ Modules that are non detectors and the CHQ Modules that are non lid as standard. Used in conjunction with
Contains: loop-powered (CHQ-DZM, CHQ-DZM(IS) and loop-powered (CHQ-DZM, CHQ-DZM(IS) and the SMB-ADAPTOR this enclosure can house
CHQ-DSC). CHQ-DSC2). any of the PCB assemblies from the Hochiki
ff 1 x Solo 100 Telescopic Pole
ff Enclosure mounted with battery space ff Enclosure mounted with battery space Smart-Fix Module range.
ff 3 x Solo 101 Extension Pole
ff 1 x Solo 200 Universal Detector Removal Tool ff Fully enclosed and robust construction ff 110 V or 230 V input ff 32 knock-outs
ff 1 x Solo 330 Aerosol Smoke Dispenser ff 110 V or 230 V input ff Regulated, true 24 V output ff Grey lid available SMB-1(LID)
ff 1 x Solo 461 Cordless Heat Detector Test Kit ff Regulated, true 24 V output ff House up to 26 Ah batteries ff Quick-release screws Polyurethane gasket
(includes 2 Battery Batons™ and Charger) ff House up to 26 Ah batteries ff Status indicators for monitored faults provides IP66 protection
ff 1 x Solo 610 Protective Carrying Bag. ff Status indicators for monitored faults ff Fully enclosed and robust construction ff Temperature resistance to +70°C, Impact
ff Intelligent battery charging and temperature ff Dual output for powering fire alarm control resistant, and Non-flammable
compensation panels remotely ff Corrosion free, resistant to most alkaline
ff Dual output for powering fire alarm control ff Intelligent battery charging and temperature and acid.
panels remotely. compensation.

41
SMB - 2 SMB - 3 PL - 3 REMOVAL TOOL - 3
An IP66 Rated, Grey (RAL7035) Enclosure A Grey (RAL7035) Enclosure Designed for Additional Programming Lead 3 Way Outer Cover Removal Tool allows the case of
designed for use with the Hochiki range of DIN use with the Hochiki range of DIN Modules. Connection for use on Hochiki devices that any photoelectric sensor or detector to be
Modules. Supplied with a transparent black Supplied with a transparent black lid as feature the square programming terminal, removed easily, even if the locking tabs have
lid as standard. The unit is supplied with a standard. The unit is supplied with a DIN Rail HCP-E(SCI) call points for example. The jack been employed. This allows easy access to
DIN Rail section (plus fixings) and will accept section (plus fixings) and will accept up to plug fits into the socket on the TCH-B200 the photoelectric chamber for maintenance
up to six Hochiki DIN Rail Modules, side-by- four Hochiki DIN Rail Modules, side-by-side. programmer and the square programming or replacement. Fits ALN-EN, ACC-EN and ATJ-
side. ff 20 knock-outs plug fits to the device. EN only.
ff Quick-release screws ff Quick-release screws ff Allows connection of TCH-B200 programmer
ff Polyurethane gasket provides IP66 protection ff Polyurethane gasket provides IP66 protection ff For use with Hochiki devices with square
ff 32 knock-outs ff Supplied with DIN Rail and fixings connector.
ff Supplied with DIN Rail and fixings ff Grey lid available SMB-3(LID)
ff Grey lid available SMB-2(LID) ff Temperature resistance to +70°C, Impact
ff Temperature resistance to +70°C, Impact resistant, and Non-flammable
resistant, and Non-flammable ff Corrosion free, resistant to most alkaline
ff Corrosion free, resistant to most alkaline and acid
and acid ff Designed to house up to 4 Hochiki DIN
ff Designed to house up to 6 Hochiki DIN Modules.
Modules.

42
CHQ - BACKBOX CHQ - ADAPTER MBB-2 SI - CAP2
The Module Backbox is designed for Adaptor for the New CHQ Modules designed to A Marine Back Box providing a splash proof A Protective Cap which can be fitted to the
installations where the CHQ Range of allow the “Smart-Fix“ range of CHQ Modules and secure fixing for the Hochiki ESP and YBO-R/SCI isolator base range, the YBO-BS
Modules - CHQ-DIM(SCI), CHQ-SZM(SCI), to be housed in existing enclosures originally CDX Marine Approved Range of Sensors base sounder or the YBO-BSB base sounder
CHQ-DZM(SCI),CHQ-DSC(SCI),CHQ-MRC(SCI), designed for the first generation CHQ-OEM and Detectors and their associated Bases. beacon when either of these devices isn’t
CHQ-DRC(SCI) & CHQ-PCM require mounting Modules by modifying the ‘footprint’ of the Provides an aesthetically pleasing solution fitted with a sensor. It can also fit the YBN-R/3
within a glanded enclosure. The unit features unit. where surface fixed devices are required. The and the YBN-R/3(SCI).
ten knock-outs suitable for cable glands ff Footprint matches older enclosure sizes housing supports four 20mm glanded entries ff Easy to Fit (Twist-fit)
(not supplied) and accepts the CHQ Modules for cabling access.
ff Allows the PCB component of a CHQ Module ff Protects Wiring Terminals on Isolator Bases
directly as a lid. ff 4 Glanded cable entry holes (glands not
to be housed in an enclosure. and Base Sounders.
ff Provides glanded cable connections supplied)
ff Compatible with all CHQ Modules ff Colour matched
ff Robust design. ff Approved Sensor and Base range
ff Provides moisture and dust resistant fixing
ff Ideal for bulk-head fixing
ff Approved to MED by GL
ff GL Type approval
ff Non-marine use version available (SBB-2).

43
A Guide To Our Sounder/ Beacon Variants Example product code

CHQ - WSB2(WHT) / RL

WHT = White Case RL = RED LEDs


RED = Red Case WL = WHITE LEDs

YBO - BSB2 CHQ - WSB2


An Addressable Loop-Powered An Addressable Loop-Powered
Base Sounder Beacon Wall Sounder Beacon

LED LED
Product Type Product Code Case Rating Product Type Product Code Case Rating
Colour Colour

Base Sounder Wall Sounder CHQ-WSB2/WL White Red 'O'


YBO-BSB2/WL White Ivory 'O'
Beacon Beacon

Base Sounder Wall Sounder CHQ-WSB2/RL Red Red 'O'


YBO-BSB2/RL Red Ivory 'O'
Beacon Beacon

Base Sounder Wall Sounder CHQ-WSB2(WHT)/WL White White ‘O’


YBO-BSB2(WHT)/WL White White ‘O’
Beacon Beacon

Base Sounder Wall Sounder CHQ-WSB2(WHT)/RL Red White 'O'


YBO-BSB2(WHT)/RL Red White 'O'
Beacon Beacon

44
A Guide To Our Conventional
Beacon Variants Product Type Product
Code
Led
Colour
Case
Colour
EN54-23 Ratings

Example product code Wall


Ceiling Fitted
Fitted
CWST-WR-S5
Conventional CWST-
Red Red W-2.4-6.2 C-3-9.4 C-6-8.6 -
R = Red Case R = Red LEDs S = Standard Base Beacon RR-W5

W = White Case W = White LEDs W = Weatherproof Base


Conventional CWST-
Red Red W-2.4-6.2 C-3-9.4 C-6-8.6 -
Beacon RR-S5

Conventional CWST-
White Red W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5
Beacon RW-S5

CWST - S5 Conventional CWST-


White Red W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5
A Conventional Beacon Beacon RW-W5

Conventional CWST-
Red White W-2.4-6.2 C-3-9.4 C-6-8.6 -
Beacon WR-S5

Conventional CWST-
Red White W-2.4-6.2 C-3-9.4 C-6-8.6 -
Beacon WR-W5
CWST - W5
A Conventional Conventional CWST-
Weatherproof Beacon White White W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5
Beacon WW-W5

Conventional CWST-
White White W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5
Beacon WW-S5

45
A Guide To Our Ceiling Product Product LED Case EN54-23 Ratings

Beacon Variants
Type Code Colour Colour

0 1* 2

Example product code


Ceiling
CHQ-CB(WHT)/ WL Beacon
CHQ-CB/WL White Ivory C-3-5 C-3-7.5 C-3.10

WHT = White Case WL = White LEDs Ceiling


CHQ-CB/WL-15 White Ivory O C-3-10 C-3-15
Beacon
RED = Red Case RL = Red LEDs

Ceiling
CHQ-CB/RL Red Ivory O C-3-7.5 C-3-10
Beacon

Ceiling
CHQ - CB CHQ-CB (WHT)/WL White White C-3-5 C-3-7.5 C-3-10
Beacon
An Addressable Loop-Powered
Ceiling Beacon
Ceiling
CHQ-CB (WHT)/WL-15 White White O C-3-10 C-3-15
Beacon

Ceiling
CHQ-CB (WHT)/RL Red White O C-3-7.5 C-3-10
Beacon

Ceiling
CHQ-CB (RED)/WL White Red C-3-5 C-3-7.5 C-3-10
Beacon

Ceiling
CHQ-CB (RED)/WL-15 White Red O C-3-10 C-3-15
Beacon

Ceiling
CHQ-CB (WHT)/RL Red White O C-3-7.5 C-3-10
Beacon

*Current default setting = light output level one. Check panel compatibility for EN54-23 Ratings.

46
A Guide To Our Wall Product Product LED Case EN54-23 Ratings

Beacon Variants
Type Code Colour Colour

0 1* 2

Example product code


Wall
CHQ-WB(WHT)/ WL Beacon
CHQ-WB/WL White Ivory W-3-5 W-3-7.5 W-3.10

WHT = White Case WL = White LEDs Wall


CHQ-WB/RL Red Ivory W-3-5 W-3-7.5 W-3-10
Beacon
RED = Red Case RL = Red LEDs

Wall
CHQ-WB(WHT)/WL White White W-3-5 W-3-7.5 W-3-10
Beacon

Wall
CHQ - WB CHQ-WB(WHT)/RL Red White O W-3-10 W-3-15
Beacon
An Addressable Loop-Powered
Wall Beacon
Wall
CHQ-WB(RED)/WL White Red O W-3-10 W-3-15
Beacon

Wall
CHQ-WB(RED)/RL Red Red O W-3-10 W-3-15
Beacon

*Current default setting = light output level one. Check panel compatibility for EN54-23 Ratings.

47
Notes:

48
Index
16091 19, 38 DFJ-AE3 17 RSM-WTM 30
16591 19 DFJ-CE3 18 SDP-3 38
ACB-EW 9 DH-24 38 SI-CAP2 43
ACC-EN 7 DRD-E 18 SMB-1 41
ACC-EN(SCI) 8 FB-1 9 SMB-2 42
ALN-EN 7 FB/024/R/W 24 SMB-3 42
ALN-EN(SCI) 8 FIRElink-25 35 SOC-E3N 17
ATJ-EN 7 FIRElink-100 35 SOLO 200 40
ATJ-EN(SCI) 8 FIRElink-400 35 SOLO 330 40
BANSHEE EXCEL 22 FIRElink-400CM 35 SOLO 423/424 40
BANSHEE EXCEL IP66 22 FIRElink Dust Filters 36 SOLO 461 40
BANSHEE EXCEL LITE 22 FIRElink Sampling Pipes 36 SOLO 823 KIT 41
BANSHEE EXCEL LITE IP66 22 FL-APIC 36 SOLO POLES 39
CCP-E 24 FL-DF1 36 SPC-ET 19
CCP-KS 25 FL-DF2 36 SR BACKBOX 15
CCP-SAVWIRE 24 FL-RC 36 TCH-B200 15, 38
CCP-W 24 HCP-E(SCI) 14 TESTIFIRE 39
CHQ-ADAPTER 43 HCP-W(SCI) 15 YBD-RA 39
CHQ-ARI 11 HE-PSU(2.5A) 41 YBN-R/3 9
CHQ-BACKBOX 43 HE-PSU(5.25A) 41 YBN-R/6 19
CHQ-CB 11, 46 HFC-SBR-23-03 31 YBN-R/6SK 21
CHQ-DIM2(SCI) 13 HFC-WSR-03 32 YBN-UA 39
CHQ-DRC2(SCI) 13 IFD-E 18 YBO-BS 10
CHQ-DSC2(SCI) 14 LDM-519-DDL 27 YBO-BSB2 11, 44
CHQ-DZM(SCI) 14 LDM-519-LP 27 YBO-R/3 10
CHQ-MRC2 13 LHDC ANALOGUE CABLE 27 YBO-R/6PA 20
CHQ-PCM(SCI) 13 LHDC DIGITAL CABLE 27 YBO-R/6R 20
CHQ-POM 12 MBB-2 43 YBO-R/6RN 20
CHQ-SIM 12 MBF-6EV 23 YBO-R/6RS 20
CHQ-SOM 12 PL-3 42 YBV-R/4 8
CHQ-SZM2(SCI) 14 PS200 15
CHQ-WB 11, 47 REMOVAL TOOL-3 42
CHQ-WPK 10 REPLACEMENT BATTERIES 33
CHQ-WS2 9 RHT-E 32
CHQ-WSB2 10, 44 RMC-E 32
CLB-E 23 ROP-E 32
CSBB-E 21 RSM-BS 33
CSB-E 21 RSM-BSB 33
CWSB-E 21 RSM-CIM 31
CWST-S5 23, 45 RSM-CP 31
CWST-W5 23, 45 RSM-EXP 30
DCD-AE3 17 RSM-IP 31
DCD-CE3 17 RSM-POM 31

49
Guides from Hochiki

BS5839 Part 1:2017 Guide BS5266 Part 1:2016 Guide


Hochiki’s BS 5839 Part 1:2017 pocket guide is designed to provide essential Hochiki’s BS 5266 Part 1: 2016 pocket guide is designed to provide essential
information for the selection, spacing and siting of fire detectors. information for the design, installation and wiring of emergency lighting products.
Other Product Range Catalogues from Hochiki

FIREscape Emergency Lighting Catalogue Specialist Product Catalogue


FIREscape® is a fully intelligent, highly cost effective and environmentally Our Specialist Product Catalogue details the range of specialist fire detection
friendly emergency lighting system, which incorporates the latest in LED and products certified for use in Marine, SIL, Intrinsically Safe and Railway
battery technology. applications.

www.hochikieurope.com/firescape www.hochikieurope.com/category/specialist-fire-detection
Your Safety, Our Technology

HOCHIKI EUROPE (UK) LIMITED


Grosvenor Road, Gillingham Business Park,
Gillingham, Kent, ME8 0SA, United Kingdom
Telephone: +44 (0)1634 260133
Facsimile: +44 (0)1634 260132
E-mail (UK Sales): sales@hochikieurope.com
E-mail (Non UK Sales): export@hochikieurope.com
www.hochikieurope.com

9-5-0-321/ISS23/JUL19

Quality Certificate No.164QMS


Assessed to ISO 9001

MANAGEMENT
SYSTEMS
Environmental Certificate No.164EMS
Assessed to ISO 14001
Affiliate Member

You might also like