Expandability
Design Design Class
Item
Class 1 Class 2 Class 3
Storage Tanks No plot space for Plot space for additional tanks shall be provided.
additional tanks shall be
provided.
Control Building/ Size of control building Control building shall be Control building shall be
Switchgear Building and switchgear building sized for minimum designed for 20 year life
shall be minimized. Use support staff. Use metal and for all support staff.
metal building approach building approach if Concrete block shall be
if acceptable. Design for acceptable. Design for used if acceptable. Design
no future expansion. limited future expansion. for future expansion
Operability and Maintainability
Design Design Class
Item
Class 1 Class 2 Class 3
Equipment Minimize. Provide space Provide space for routine Follow 1 EG-2. Provide
only for routine and safe and safe access for space for routine and safe
access for operation & operation & maintenance. access for operation &
maintenance. Consider Provide space for maintenance. Also provide
packaged units and/or specialized maintenance. space for specialized
modular design and Consider limited space maintenance and
elevating rotating for turnaround turnaround accessibility.
equipment to achieve accessibility. TIC is 0.2% greater than
compactness & cost TIC is 0.2% greater than Class 1.
savings. Class 1.
Pipe Rack See above. See above. Clearances shall conform to
Clearance TIC is 0.1% greater than 1 EG-2.
Class 1. TIC is 0.1% greater than
Class 1.
Pipe Rack Capacity Minimum size without Varying widths shall be Piperack shall have 20%
future provisions. “Tee” used where cost space for future additions in
supports shall be used. effective. Provide space addition to identified
for identified futures. futures.
TIC is 0.1% greater than TIC is 0.1% greater than
Class 1. Class 1.