 A380 
TECHNICAL TRAINING MANUAL 
MAINTENANCE COURSE - T1 & T2 (RR / Metric)  
LEVEL II - ATA 26 Fire Protection Systems 

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 1/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 2/52
 

5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

This document must be used for training purposes only

Under no circumstances should this document be used as a reference

It will not be updated.

All rights reserved


No part of this manual may be reproduced in any form,
by photostat, microfilm, retrieval system, or any other means,
without the prior written permission of AIRBUS S.A.S.

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 3/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 4/52
 

5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

LEVEL II - ATA 26 FIRE PROTECTION SYSTEMS


Fire Protection System
Fire Protection System Description (2) . . . . . . . . . . . . . . . . . . . . . . . . 2
Fire Protection System Operation, Control & Indicating (2) . . . . . . 14
Smoke Detection System
Cargo Smoke Detection & Fire Extinguishing Description (2) . . . . 24
Avionics & In-Flight Entertainment Compartment Smoke Detection
System Description (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Lavatories Smoke Detection Description (2) . . . . . . . . . . . . . . . . . . 30
Smoke Detection Systems Operation, Control & Indicating (2) . . . . 34

0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   TABLE OF CONTENTS Mar 21, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 1

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 5/52
 

5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

FIRE PROTECTION SYSTEM DESCRIPTION (2)


- the ECAM.
Engine Fire Detection Aural warnings sound through the loudspeakers.
In case of engine fire on ground, the action is as follows:
General Presentation
- the THRust levers must be on IDLE position,
The technology of the Fire Detectors is electro-pneumatic. Each Fire - the PaRKing BRaKe must be on the ON position,
Detector is made of sensing element and responder assembly. The - all the ENG MASTER panel switches must be OFF,
responder assembly sends detection signal to the Fire Detection Unit - the FIRE P/Bs have to be pushed to be released,
(FDU). Two independent loops (LOOP A and LOOP B) are installed - the AGENT P/Bs 1 and 2 can be pushed to discharge.
in each fire zone. In addition, a failure message is transmitted to the Central Maintenance
The FDU via the Conversion Module (CM) warns the crew through System (CMS).
Flight Warning System (FWS) and Engine/Fire Integrated Control
Panel (ICP).
In normal mode, when fire detection is confirmed by the FDU, the
following fire warnings are triggered on:
- the ENGine/FIRE ICP,
- the ENG MASTER Control Panel,
- the MASTER WARN lights located on the glareshield panel,
- the EWD and the SD,
These visual warnings are related to aural warnings (constant repetitive
chime).
A Bite function monitors the condition of the FDU, of the CM and
their associated inputs. The BITE function analyses, confirms the
1 faults and stores them.
0
2
0
L
E Fire And Fault Indications
V
LE An operational test on engines, APU and L/G bay can be done in flight
S
D
6
2
or on ground, controlled by the TEST P/B on Engine/Fire ICP through
M the single FDU.
L
-
0 In case of engine fire, visual messages appear on:
T
0
T - the ENG MASTER panel with a red FIRE indication on the dedicated
D
0 engine,
L
-
2
8
- the ENG/FIRE ICP with a red FIRE indication on the dedicated
0
6 engine,
0
Y
0 - the MASTER WARNINGS,
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 2

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 6/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
LE
S
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 ENGINE FIRE DETECTION - GENERAL PRESENTATION & FIRE AND FAULT INDICATIONS
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 3

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 7/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

FIRE PROTECTION SYSTEM DESCRIPTION (2)


Engine Fire Extinguishing

System Description
The system has two main functions:
- extinguish any fire in the protected zones of the nacelle as soon as
possible. A fire can be due to excessive overheat or flammable fluid
leaks and can endanger the A/C safety,
- prevent engine fire extension: the engine is isolated from the rest of 
the A/C.
The engine fire extinguishing system is a High Rate Discharge system.
This includes the systems based on a rapid discharge (around 1 sec.)
of an extinguishing agent pressurized in a vessel.
The extinguishing agent is the Halon 1301.
The fire extinguishing system includes for each engine:
- one ENG/FIRE P/BSW installed on the ENG/FIRE ICP,
- two SQUIB/DISCH (AGENT 1 and AGENT 2) P/BSWs located on
the same panel,
- two fire extinguisher bottles which are made up of a spherical
container, a discharge head, a cartridge, and a Temperature
Compensated Pressure Switch,
- extinguishing lines routed in the pylon and leading to the nacelle.
1
0
2
0
L
E
V
LE
S
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 4

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 8/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
EL
S
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 ENGINE FIRE EXTINGUISHING - SYSTEM DESCRIPTION
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 5

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 9/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

FIRE PROTECTION SYSTEM DESCRIPTION (2)


Engine Fire Extinguishing (continued)

Activating the Extinguisher


Each SQUIB/DISCHARGE (AGENT 1 and AGENT 2) P/BSW agrees
respectively with the fire extinguisher bottle 1 and bottle 2.
By acting on the ENG/FIRE P/BSW, the cartridge firing system is
armed. The SQUIB legend (white) comes on after this action.
The DISCH legend (amber) comes on when the Temperature
Compensated Pressure Switch installed on the fire extinguisher bottle
transmits a low-pressure signal (via FDU), which indicates the
discharge or a leakage of the fire extinguisher bottle.
Human factor point:

WARNING: BAT BUS CONTINUALLY SUPPLIES THE


EXTINGUISHING SYSTEM, SO THE SQUIB P/B
MUST BE PUSHED ONLY IN CASE OF FIRE.

1
0
2
0
L
E
V
LE
S
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 6

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 10/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
LE
S
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 ENGINE FIRE EXTINGUISHING - ACTIVATING THE EXTINGUISHER
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 7

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 11/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

FIRE PROTECTION SYSTEM DESCRIPTION (2)


The DISCH legend (amber) comes on when the Temperature
APU Fire Protection Compensated Pressure Switch installed on the fire extinguisher bottle
transmits a low-pressure signal (via FDU), which indicates the discharge
The fire protection system includes:
- the fire detection sub-system, or a leakage of the fire extinguisher bottle.
In case of fire on ground, the procedure is the same except that the bottles
- the monitoring of fire extinguishing system,
are automatically triggered through the FDU and the APU/FIRE light
- on ground the APU automatic fire extinguishing control.
comes then on. An operational test can be performed in flight or on the
The fire extinguishing system includes for each engine:
ground via TEST P/B on ENGINE/FIRE ICP.
- one APU/FIRE P/BSW installed on the APU/FIRE ICP,
The BITE test is done at power up or when the CMS requests the test.
- one SQUIB/DISCH P/BSW installed on the same panel,
This test can be done only on ground. Engine, APU and Main Landing
- one fire extinguisher bottle which is made of a spherical container, a
Gear (MLG) bays fire detection are tested.
discharge head and a cartridge,
Human factor point:
The fire detectors are installed in the APU compartment and have a single
shot fire-extinguishing system. The CM is installed in a pressurized area
WARNING: BAT BUS CONTINUALLY SUPPLIES THE
for the APU compartment. When the temperature in the monitored zone EXTINGUISHING SYSTEM, SO THE SQUIB P/B MUST
reaches the defined threshold, the detector triggers warning sequence.
BE PUSHED ONLY IN CASE OF FIRE.
The FDU via the CM collects then all detector value. The FDU warns
the crew through the FWS and on the APU/FIRE ICP.
The technology of the Fire detector is Electro-pneumatic. Each fire
detector is made of sensing element and responder assembly.
An electrically operated squib, installed on the bottle, is armed from the
APU/FIRE ICP through the AGENT P/BSW for the discharge.
1 Two independent loops (LOOP A and LOOP B) are installed in each fire
0
2 zone. These loops are completly segregated.
0
L
E If overheat is detected in flight, visual messages appear on:
V
LE
S
- the APU/FIRE ICP with red FIRE indication,
D - the MASTER WARNINGS through the FWS,
6
2
M - the ECAM through the FWS.
L
-
0 Aural warnings sound through the loudspeakers.
T
0 A message is also sent to the CMS.
T
D
0 By acting on the APU/FIRE P/BSW, the cartridge firing system is armed.
L
-
2 On the SQUIB/DISCH P/BSW (on the APU/FIRE Integrated Control
8
0
6
0
Panel), the SQUIB legend (white) comes on after this action.
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 8

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 12/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
LE
S
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 APU FIRE PROTECTION
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 9

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 13/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

FIRE PROTECTION SYSTEM DESCRIPTION (2)


Landing Gear Fire Protection

Four zones are protected for the Landing Gear System:


- the right Wing Landing Gear (WLG) bay,
- the left WLG bay,
- the Body Landing Gear (BLG) bay (RH side),
- the BLG bay (LH side).
Each L/G compartment has two fire detectors.
The L/G fire protection system uses the dual loop (LOOP A and LOOP
B) principle in each L/G bay.
The loops are connected in parallel and operate according to an AND
logic.
If overheat is detected, FDU sends signal to the FWS:

- for horn master warning,


- for visual MASTER CAUTION message on the MASTER WARNINGS,
- for message on the ECAM.
A message is also sent to the CMS.
An operational test can be done in flight or on ground controlled by the
test P/B on the ENGINE/FIRE ICP.

1
0
2
0
L
E
V
LE
S
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 10

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 14/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
LE
S
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 LANDING GEAR FIRE PROTECTION
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 11

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 15/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

FIRE PROTECTION SYSTEM DESCRIPTION (2)


Power Supply

Each FDU and CM has its own power supply. The channels A of the CM
are supplied by the 28VDC (ESS BUS). The channels B of the CM are
supplied by the 28VDC (DC BUS 2) through Solid State Power Controller
(SSPC).
The SQUIB 1 and the SQUIB 2 of the bottles are respectively supplied
by the 28VDC (HOT BUS) and the 28VDC (ESS BUS).
The AGENT P/Bs are supplied by the 28VDC (HOT BUS and ESS BUS).

1
0
2
0
L
E
V
LE
S
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 12

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 16/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
LE
S
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 POWER SUPPLY
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM DESCRIPTION (2) Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems Page 13

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 17/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

FIRE PROTECTION SYSTEM OPERATION, CONTROL & INDICATING (2)


General

1
0
2
0
L
E
V
LES
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 14

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 18/52

 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
LES
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 GENERAL
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 15

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 19/52
 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

FIRE PROTECTION SYSTEM OPERATION, CONTROL & INDICATING (2)


ENG FIRE Warning and Action

1
0
2
0
L
E
V
LES
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 16

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 20/52
 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V

SLE
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 ENG FIRE WARNING AND ACTION
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 17

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 21/52
 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

FIRE PROTECTION SYSTEM OPERATION, CONTROL & INDICATING (2)


APU FIRE Warning and Action

1
0
2
0
L
E
V
LES
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 18

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 22/52
 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
LS
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 APU FIRE WARNING AND ACTION
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 19

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 23/52
 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

FIRE PROTECTION SYSTEM OPERATION, CONTROL & INDICATING (2)


MLG FIRE Warning

1
0
2
0
L
E
V
E
LS
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 20

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 24/52
 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
LS
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 MLG FIRE WARNING
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 21

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 25/52
 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

FIRE PROTECTION SYSTEM OPERATION, CONTROL & INDICATING (2)


Fire Warning Test

1
0
2
0
L
E
V
E
SL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 22

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 26/52
 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
SL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 FIRE WARNING TEST
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   FIRE PROTECTION SYSTEM OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 23

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms


 
27/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

CARGO SMOKE DETECTION & FIRE EXTINGUISHING DESCRIPTION (2)


Power Supply

The cargo smoke detection and fire extinguishing system has:


- a cargo smoke panel on cockpit panel to activate and control the Fire
Extinguishing System via Cabin Intercommunication Data System (CIDS),
- two Fire Extinguishing Data Converters to monitor and ignite the squib,
- three fire extinguishing bottles to store the fire-extinguishing agent
Halon 1301,
- four extinguishing nozzles in the FWD and five extinguishing nozzles
in the AFT/BULK cargo compartments to supply the fire extinguishing
agent,
- one flow metering equipment downstream of the second and third bottle
on a support to regulate the outflow of the bottles, and to maintain the

minimal
time, extinguishing agent concentration over the required suppression
- one diverter valve to direct the Halon 1301 via piping system to the
FWD or AFT/BULK cargo compartment.
28VDC NORMal BUS and 28VDC ESSential BUS supply the Fire
Extinguishing Data Converter 1. 28VDC NORM BUS and 28VDC
NORM BUS 2 supply the Fire Extinguishing Data Converter 2. If the
A/C electrical PoWeR is the only EXTernal PWR AVAILable, the Fire
1 Extinguishing Data Converters are supplied by the 28VDC GrouND ESS
0
2
0 BUS.
L
E
V
E
UL
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   CARGO SMOKE DETECTION & FIRE EXTINGUISHING Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems DESCRIPTION (2) Page 24

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms


  28/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
LU
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 POWER SUPPLY
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   CARGO SMOKE DETECTION & FIRE EXTINGUISHING Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems DESCRIPTION (2) Page 25

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms


  29/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

CARGO SMOKE DETECTION & FIRE EXTINGUISHING DESCRIPTION (2)


not available in the respective compartments while in test condition. The
Test Functions cartridges inclusive associated wiring is checked either automatically
(every 30 min.) or on flight crew request by the PTT. This is not a
In case of cargo smoke detection, the cargo smoke detectors send a
discrete signal to the CIDS-Smoke Detection Function (SDF). The complete
squib faulttest of all wires
is indicated in necessary
the cockpitfor
onfiring the squibs.
the ECAM and onThe
thedouble
cargo
CIDS-SDF transmits alarm and fault indications to the Flight Warning
smoke panel, or by PTT request. The faults including the fault of one
System (FWS) and data to the Central Maintenance System (CMS)
squib are transmitted to the CMS.
through AFDX Bus.
While in interactive mode, the On-board Maintenance Terminal (OMT)
The FWS provides the visual and acoustical alarms and fault indications
allows smoke alarm testing of all compartments, and complete system
on:
condition testing. The system test does a system-wide check including
- The EWD of the ECAM,
all redundancies. Like the PTT condition, the active CIDS-SDF channel
- The Master Warning P/BSWs,
does the Smoke Warn Test. Since single compartments are selectively
- The loudspeakers.
tested at a time, a smoke detection is available in all other compartments
On the Cargo Smoke Panel:
not under test. The test is carried out continuously until manually
- a detected smoke in FWD (or AFT/BULK) Cargo compartment is shown
by a red colored legend SMOKE on the AGENT TO FWD (or AGENT cancelled or interactive mode is no longer available.
TO AFT) P/BSWs,
- a squib fault is shown by the DISCH indication,
- a low pressure in one of the three fire extinguishing bottles is shown
by a white colored legend BTL1, BTL2 or BTL3,
By operating the P/BSWs 'AGENT TO FWD' and 'AGENT TO AFT',
fire the squibs of the FWD cartridges of the diverter valve.
1 The smoke detection system offers two means of in-situ functional testing:
0
2
0 - the Push To Test (PTT),
L
E
V - the Onboard Maintenance System (OMS).
E
LU A Push To Test (PTT) P/BSW is provided on the cargo smoke panel to
D let the flight crew check the capability of the system to discharge in case
6
2
M of a fire event. The PTT is available during all flight phases and, when
L
-
0 activated, it places all compartments falling under the category
T
0 non-customized (lower deck cargo compartments, main avionics
T
D
0 compartment, emergency avionics compartment, In-Flight Entertainment
L
-
2 Center (IFEC), additional electronics compartment) and inaccessible by
8
0
6
0
alarm condition. The active CIDS-SDF channel does the test as long as
Y
0 the PTT is commanded (however at least for 5 sec.). Smoke detection is
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   CARGO SMOKE DETECTION & FIRE EXTINGUISHING Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems DESCRIPTION (2) Page 26

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms


 
30/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
UL
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 TEST FUNCTIONS
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   CARGO SMOKE DETECTION & FIRE EXTINGUISHING Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems DESCRIPTION (2) Page 27

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms


 
31/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

AVIONICS & IN-FLIGHT ENTERTAINMENT COMPARTMENT SMOKE DETECTION SYSTEM


DESCRIPTION (2)
- the Onboard Maintenance Terminal (OMT).
Detection Function The operational test is triggered from the TEST P/B. This allows a
Pairs of duct-type smoke detectors carry out the smoke detection function. momentary check of the complete chain from the smoke detector, over
the CIDS-SDF to the indication system generated by the Flight Warning
They are installed in the air extraction ducts ventilating the clusters of 
System (FWS) on loudspeakers and Integrated Cockpit Panels (ICPs):
avionics racks. Each smoke detector relies on ducted air to continuously
- AVioNiCS SMOKE P/B on the VENTilation control panel,
transport combustion particles into the housing.
- PAX SYStem P/BSW on the Flight/ConTroL panel.
The smoke detectors monitor the air extracted from:
This test is available during all flight phases. When the test is in progress,
- the main avionics compartment,
smoke detection function is not available in the related compartments
- the emergency avionics compartment,
under test.
- the In-Flight Entertainment Center (IFEC),
When the OMT is in interactive mode and ground condition fulfilled, a
- the rear avionics compartment (optional).
selective test of smoke alarms in the different compartments and the
The main system controller is the Cabin Intercommunication Data System
performance of a complete system test can be done. As each compartment
(CIDS) - Smoke Detection Functions (SDFs), located in the CIDS can be selectively tested, smoke detection function still available in all
directors, which manage the smoke detection function.
other compartments not under test. The test is carried out either from the
Two segregated Controller Area Network (CAN) buses (C and D) allow
TEST P/B or from the OMT; but the smoke warning tests are always
the communication between the CIDS-SDF and the smoke detectors in
done by the active CIDS-SDF only.
the main avionics compartment, the emergency avionics compartment
and the IFEC. Two other segregated CAN buses (A and B) allow the
communication with the smoke detectors in the rear avionics compartment
(optional).
1 The smoke detectors are supplied with 28 VDC from the DC NORMal
0
2
0
L BUS 2 or DC ESSential BUS.
E
V In case of smoke detected by one smoke detector, a smoke signal is sent
E
TL to the CIDS-SDF. If smoke is detected by both smoke detectors at the
D
6 same location, an alarm status is generated; the CIDS-SDF sends a smoke
2
M
L
-
warning to the Flight Warning Computer (FWC) via the Avionics Full
0 Duplex Switched Ethernet (AFDX) network.
T
0
T
D
0 Test Function
L
-
2
8
0 The smoke detection system can be tested via:
6
0
Y - the TEST P/B on the CARGO SMOKE overhead panel,
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   AVIONICS & IN-FLIGHT ENTERTAINMENT COMPARTMENT Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems SMOKE DETECTION SYSTEM DESCRIPTION (2) Page 28

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 32/52
 
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
TL
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 DETECTION FUNCTION & TEST FUNCTION
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   AVIONICS & IN-FLIGHT ENTERTAINMENT COMPARTMENT Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems SMOKE DETECTION SYSTEM DESCRIPTION (2) Page 29

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 33/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

LAVATORIES SMOKE DETECTION DESCRIPTION (2)


Electrical Power

The Smoke Detection System is based on a controller-sensor architecture.


The main system controller is installed in the Cabin Intercommunication
Data System (CIDS) Director. The smoke detection control function is
done by the CIDS-Smoke Detection Function (SDF).
The CIDS-SDF is powered by the 28VDC NORMal DC BUS 2 and the
28VDC ESSential BUS.
Each lavatory is a separate compartment from a fire protection point of 
view. A single ambient smoke detector is installed in the lavatory ceiling
adjacent to the air extraction. The smoke detector is connected to a
Decoder/Encoder Unit (DEU)-B in the vicinity of the lavatory. The
DEU-B is supplied with the 28VDC NORM DC BUS 2 and the 28VDC
ESS BUS.
In case of lavatory smoke alert, lavatory smoke detection alarm and fault
signals are shown on the Flight Attendant Panel (FAP) and mini-FAP
(optional). The CIDS-SDF sends also a smoke alert that generates visual
and acoustical cockpit warnings.

1
0
2
0
L
E
V
E
VL
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   LAVATORIES SMOKE DETECTION DESCRIPTION (2) Mar 17, 20 06
LEVEL II - ATA 26 Fire Protection Systems Page 30

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 34/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
VL
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 ELECTRICAL POWER
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   LAVATORIES SMOKE DETECTION DESCRIPTION (2) Mar 17, 20 06
LEVEL II - ATA 26 Fire Protection Systems Page 31

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 35/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

LAVATORIES SMOKE DETECTION DESCRIPTION (2)


Test Functions

In case of lavatory smoke alert, a SMOKE DETECTION page appears


on the FAP as a synoptic graphic and a red icon is displayed at the affected
location.
Simultaneous, the CIDS-SDF sends smoke alerts to the Flight Warning
Computer (FWC) that generates:
- a warning message on the Engine/Warning Display (EWD) of the
ECAM,
- a red MASTER WARNINGS,
- a repetitive chime.
In the cabin, a smoke alert from the lavatory triggers the respective Area
Call Panel (ACP) and an amber light comes on. The related message is
shown on all Attendant Indication Panels (AIP). Also the respective call
light comes on in the flashing mode.
The SMOKE P/B RESET of the Additional Attendant Panel (AAP) can
be activated to silence the chime and to reset all visual warnings on the
ACPs, the AIPs, and the outside wall-mounted smoke/PAX call indicator
of the affected lavatory.
The CIDS director transmits a signal to the DEU-A, which activates a
triple low chime sequence emitted through the loudspeaker in the cabin.
1 Maintenance data and specific tests are done by the Onboard Maintenance
0
2
0 System (OMS) through an Onboard Maintenance Terminal (OMT). The
L
E OMT allows smoke alarm testing of all compartments, and complete
V
E
LV system condition testing. The system test does a system-wide check 
D including all redundancies. The smoke warn test is done by the active
6
2
M CIDS-SDF channel.
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   LAVATORIES SMOKE DETECTION DESCRIPTION (2) Mar 17, 20 06
LEVEL II - ATA 26 Fire Protection Systems Page 32

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 36/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
VL
D
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 TEST FUNCTIONS
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   LAVATORIES SMOKE DETECTION DESCRIPTION (2) Mar 17, 20 06
LEVEL II - ATA 26 Fire Protection Systems Page 33

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 37/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

SMOKE DETECTION SYSTEMS OPERATION, CONTROL & INDICATING (2)


General

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 34

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 38/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 GENERAL
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006
LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 35

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 39/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

SMOKE DETECTION SYSTEMS OPERATION, CONTROL & INDICATING (2)


Cargo Bay Smoke Warning

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 36

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 40/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 CARGO BAY SMOKE WARNING
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 37

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 41/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

SMOKE DETECTION SYSTEMS OPERATION, CONTROL & INDICATING (2)


Avionics Compartment Smoke Warning

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 38

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 42/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 AVIONICS COMPARTMENT SMOKE WARNING
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 39

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 43/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

A380 TECHNICAL TRAINING MANUAL

SMOKE DETECTION SYSTEMS OPERATION, CONTROL & INDICATING (2)


IFE Bay Smoke Warning

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 40

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 44/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om
A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 IFE BAY SMOKE WARNING
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 41

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 45/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om
A380 TECHNICAL TRAINING MANUAL

SMOKE DETECTION SYSTEMS OPERATION, CONTROL & INDICATING (2)


Smoke Warning Test by PTT for Non-Customized Areas

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 42

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 46/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om
A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 SMOKE WARNING TEST BY PTT FOR NON-CUSTOMIZED AREAS
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 43

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 47/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om
A380 TECHNICAL TRAINING MANUAL

SMOKE DETECTION SYSTEMS OPERATION, CONTROL & INDICATING (2)


Crew Rest Smoke Warning

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 44

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 48/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om
A380 TECHNICAL TRAINING MANUAL

1
0
2
0
L
E
V
E
TL
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 CREW REST SMOKE WARNING
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 45

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 49/52
5/25/2018
A380 TECHNICAL TRAINING MANUAL
A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

SMOKE DETECTION SYSTEMS OPERATION, CONTROL & INDICATING (2)


Lavatory Smoke Warning

1
0
2
0
L
E
V
E
L
T
O
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 46

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 50/52
5/25/2018
A380 TECHNICAL TRAINING MANUAL
A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

1
0
2
0
L
E
V
E
L
TO
6
2
M
L
-
0
T
0
T
D
0
L
-
2
8
0
6
0 LAVATORY SMOKE WARNING
Y
0
L

MAINTENANCE COURSE - T1 & T2 (RR / Metric)   SMOKE DETECTION SYSTEMS OPERATION, CONTROL & Mar 17, 2006

LEVEL II - ATA 26 Fire Protection Systems INDICATING (2) Page 47

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 51/52
5/25/2018 A380-LEVEL II - ATA 26 Fire Prote c tion Syste ms - slide pdf.c om

AIRBUS S.A.S.
31707 BLAGNAC cedex, FRANCE 
STM 
REFERENCE L0Y06082 
MARCH 2006 
PRINTED IN FRANCE 
AIRBUS S.A.S. 2006 
ALL RIGHTS RESERVED 

AN EADS JOINT COMPANY 

http://slide pdf.c om/re a de r/full/a 380-leve l-ii-a ta -26-fire -prote c tion-syste ms 52/52