E4174-542/572/575
LINEAR GAGE
SERIES 542/572/575
2
Features
1. A range of models available
4. Secured with nuts The linear gages offer five measuring ranges of 5, 10, 25, 50, and 100mm.
Different output modes are also available, including pulse waveform,
Digimatic Code (SPC) and sine wave (limited to the LGH with 0.01mm
ES Counter resolution). There are four resolution settings to choose from in pulse
waveform output: 0.005, 0.001, 0.0005 and 0.0001mm. Select the model
offering specifications best suited for your application.
3. Space-saving design
The slender design of the gage enables installation in confined spaces.
Slim-line models with outside diameters of 8mm are also available for
I/O measurements in spaces of 10mm or less. These gages come in two
RS-232C different cable arrangements— vertical and horizontal— to suit the type of
Digimatic Code(SPC) fixture used.
RS Link
4. Secured with nuts
EV Counter The gage can be installed easily and securely by drilling a hole in the flat
plate and mounting the gage securely with a nut. (The specification varies
by model. The use of a nut is a standard specification with some models,
while others require special accessories. Some models cannot be secured
with nuts. Check the specifications for each model.)
LINEAR GAGE
3
ALL MODELS OF LINEAR GAGE
Gage Heads
Output Measuring Range
[Resolution] 5mm (.2”) 10mm (.4”) 25mm (1”) 50mm (2”)
0.25µm pitch Laser Hologage
Sign Wave
[0.00001mm]
(1µinch)
Accessories
Refer to p.8 • Accessories for gage head: p.16
• Accessories for ES, EF and EV counter: p.23
Square Wave LGB Laser Hologage • Accessories for SD-D1/D2: p.24
[0.0001mm]
(4µinch)*1
Refer to p.12
LGD-M
4
Display Units (Counters)
Single function Type Multi-function Type Multi-Gage System
100mm (4”)
KH Counter
Refer to p.8
EF Counter
Refer to p.21
EV-16P
Refer to p.20
(Not compatible with the LGF
LG with 0.5 mm resolution.)
Refer to p.22
Refer to p.21
Refer to p.15
SD-D2 EV-16D
Refer to p.20
SD Counter
SD-D1
Refer to p.24 Refer to p.22
Refer to p.24
LINEAR GAGE
5
Applications
Multipoint measurement Measurement of camshaft displacement
of automobile doors The linear gage (LGF-125L with EF counter) can be used to
The linear gage (LGS-1012 with EV counter) can be used to measure camshaft lift.
perform multi-point measurements for automobile doors and The EF counter is easily installed in the equipment panel.
evaluate errors against the specified tolerances.
When there are many points to measure, the use
of the LGS gage provides higher cost-effectiveness.
M
iGO/
tEN
uFG
t−
oP
y
o
Z
E
R △
O
T
P
IMM
.
RAI
S <
EL
XN
TI
M >
IP
TE
A %
K L
C O
L A
R D
M
iGO/
tEN
uFG
t−
oP
y
o
Z
E
When shearing force
R △
O
T
P
IM M
.
RA I
S <
EL
XN
TI
M >
IP
TE
A %
K L
C O
L A
is to be exerted on
R D
the gage, as shown
M
iGO/
tEN
uFG
t−
oP
y
in the figure, take
o
Z
E
R △
O
T
P
IMM
.
RAI
S <
EL
XN
measurements
TI
M >
IP
TE
A %
K L
C O
L A
R D
indirectly using a
M
fixture or the like in
iGO/
tEN
uFG
t−
oP
y
o
Z
E
R △
order to avoid
T
P
IMM
.
RAI
S <
EL
XN
TI
M >
IP
TE
A %
K L
C O
L A
applying an excess
R D
load on the gage.
Measuring displacement
Measuring
the door shape
Analog output
Deflection data
tolerance
judgement
Plotted
When shearing force is to be exerted on deflection data
the gage, as shown in the figure, take
measurements indirectly using a fixture
Measuring displacement or the like in order to avoid subjecting
the gage to an excessive load.
6
Measurement of cylindrical pin displacement Multipoint measurement of VTR chassis
The linear gage (LGB-110 with EF-12PR counter) can be used to The linear gage (LGF-110L with EV counter) can be used to
measure the displacement of tape-winding capstan pins in measure VTR components at several points.
cassette recorders.
EF-12PR counter is capable of calculating sums and differences
between two gages.
X-direction:
Measuring pin
displacement
Y-direction:
Measuring pin
displacement
Multi-points
measurement/judgement
Mit
uto
yo
ES-P
Fn
P.S
ET
LINEAR GAGE
7
Laser Hologage Display unit is provided
542-923-1
The Mitutoyo Laser Hologage is a high-end digital gaging
system that employs diffracted laser beam interference to make
highly accurate and repeatable measurements. It features ultra-
fine diffraction gratings which are holographically recorded on
the scale. The Laser Hologage is suitable for measuring ultra- 45.4 Unit: mm
high precision parts, especially those in semiconductor and Dimensions
related industries (See page 39 for explanation on hologram.).
Connector for
lifting cable
FEATURES
85
146 (0.01µm type)
• Highly accurate measurement due to an ultra-high resolution
of 0.00001mm (0.01µm), which is close to the performance
10 (Measuring range)
of laser interferometers.
• Excellent measuring stability — the design is also highly
25
0
Ø15h6 -0.011
resistant to unfavorable environmental conditions such as air (Stem dia.)
movement and atmospheric pressure changes.
• High-precision linear ball bearings are used in the guide for
extremely smooth movement and exceptional durability. 18
0.01mm type with
10
R5 carbide point
• A display unit is provided. 40 20
1/ 2
971752 Stem fixture for Laser Hologage Refer to p.30 I
A
LOAD
971753 Spindle lifting cable for Laser Hologage Refer to p.17
KH
971750 Laser Hologage stand Refer to p.17
8
Display Unit
SPECIFICATIONS
Order No. 100V 542-923 542-924
(including the 120V 542-923-1A 542-924-1A
display unit) 220V 542-923-1D 542-924-1D
240V 542-923-1E 542-924-1E
240V 542-923-1F 542-924-1F
Resolution 0.00001mm (.000001")
Range 10mm (.4")
Accuracy (20°C) 0.1µm
Repeatability (2σ) 0.02µm
Measuring force Upward ( ) 0.55N or less 0.1N
Horizontal ( ) 0.45N or less —
Downward ( ) 0.35N or less —
Dust/Water protection level Not specified
Contact point R5mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm)
Stem diameter Ø15mm
Bearing type High-precision linear ball bearing
Position-detection sensor Laser-hologram measuring sensor
Max. response speed 250mm/s
Output signal 0.25µm pitch, 90° phase difference, two-phase sine wave
Display 8-digit fluorescent tubes and a [-] sign
Functions Zero-set, preset, halved reading, double reading (diameter display), ABS/INC coordinate switching,
counting direction switching, mm/inch conversion, linear error compensation, error alarm
Data output Via RS-232C interface (provided)
Power supply 100-120V/200-240V AC, 50/60Hz
Power consumption Approx. 30VA
Operating environment 10°C to 30°C (20%RH to 80%RH, without condensation)
Mass Laser Hologage: 0.2kg (excluding cable) Display unit: 2kg.
Standard accessories Wrench for contact point (538610)
8
LGB
Laser Hologage
0.0001mm
0.0001mm (0.1µm)
(0.1µm) Reading
Reading
Differential Square-wave Output
542-711-1
542-246
Ø9
18
FEATURES
75
L
• The 0.0001mm reading type LGB linear gage (542-246) Ø14
4.9 (thread)
comes with a clamping nut on the stem. Clamping nut
(HIROSE) (No.200365)
5 (Measuring
RM12BPG-6P 30 20.4
L=11.5~13.0
OPTIONAL ACCESSORIES
range)
Order No. Description 45.4
85
238773 Rubber boot for LGB (spare) Refer to p.16
971751 Stem fixture for Laser Hologage Refer to p.30 10 (Measuring range)
971752 Stem fixture for Laser Hologage Refer to p.30 25
0
Ø15h6 -0.011
971753 Spindle lifting cable for Laser Hologage Refer to p.17
Stem dia
971750 Laser Hologage stand Refer to p.17
SPECIFICATIONS
Model No. LGB Laser Hologage*1
Order No. 542-246 542-711-1 542-712-1
Resolution 0.0001mm (.000005”)
Range 5mm 10mm
Accuracy (20°C) 0.8µm 0.2µm
Measuring force Upward ( ) Approx. 0.65N or less 0.55N or less 0.1N
Horizontal ( ) Approx. 0.6N or less 0.45N or less —
Downward ( ) Approx. 0.55N or less 0.35N or less —
Dust/Water protection level IP-54 Not Specified
Contact point R1.5mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm)
Stem diameter Ø9.5mm Ø15mm
Bearing type Linear ball bearing High-precision linear ball bearing
Position-detection sensor Transmission-type photoelectric linear encoder Laser-hologram measurement sensor
Max.Responnse Speed 380mm/sec 250mm/sec
Output signal 0.4µm pitch, 90° phase difference, 0.25µm pitch, 90° phase difference, differential square wave
differential square wave (RS-422A equivalent) (RS-422A equivalent)*2
Cable length 2m
Power supply +5V ± 5% (power-supply ripple 200 mV p-p max.)
Power consumption 150mA 200mA
Operating environment 10°C to 30°C (20%RH to 80%RH, without condensation)
Mass 160g 200g (excluding cable)
Compatible counter EF counter with 0.0001mm resolution.[See page 21]
Standard accessories Wrench for contact point (538610) Wrench for contact point (538610)
Wrench for the nut (200168)
Remarks with a clamping nut on the stem Low force type
*1: Only one laser hologage may be connected to the EF counter. To connect two gages, use a 542-062-1 (without AC adapter) and an external power supply (12 to
24 VDC, 1A or greater).
*2: The signal output uses a special pitch (intervals) of 0.25mm. The values are converted to 0.0001mm resolution on the counter side.
LINEAR GAGE
9
LGF
0.0005/0.001mm Reading
Differential
Differential Square-wave
Square-wave Output
The LGF Linear Gages are Mitutoyo's new, low-cost type 542-121/131 542-123/133
electronic gage heads designed to fit into very tight spaces.
Employing an improved structure for the spindle guide, the LGF 542-122/132
is highly resistant to external shock and vibration.
FEATURES
• Excellent structure of protection
against dust and water splash (IP-66) in Dimensions Unit: mm
harsh shop-floor environments.
3.5
6.4
• Output differential square wave signals 57.5 0.6 (screw
0.6 (screw
3.5
40.5 top height) 14.8 6.4 54.6
for a wide range of applications. 36.5 11.2 37.6 top height) 20
54.6 0.6 (screw 34 + 10 10.86
• Use linear stroke bearings on the +1
34 0 5.6
37.6 top height) 20
spindle movement for durability +1
34 0 10.86
50.5
17.3
• Thrust Stem with a clamping nut is
20
23
24.5
optional.
20
20
75.9
168.9
109
128.5
Clamping nut for thrust stem
OPTIONAL ACCESSORIES
14 6.7
202.1
310.4
0
Ø8 - 0.009
902434 Extension cable (5m) Refer to p.16
10.6 or longer
21.5
(stroke)
M9.5x0.5
29.1
Ø15 - 00.015
for thrust stem
Clamping nut
6
26 or longer
SPECIFICATIONS
Order No. 542-121 542-131 542-122 542-132 542-123 542-133
Resolution 0.001mm 0.0005mm 0.001mm 0.0005mm 0.001mm 0.0005mm
Measuring range 10mm 25mm 50mm
Accuracy (20°C) (1.5+L/50) µm (L=mm)
Measuring force Upward ( ) 1.2N or less 4.6N or less 5.7N or less
Horizontal ( ) 1.1N or less 4.3N or less 5.3N or less
Downward ( ) 1.0N or less 4.0N or less 4.9N or less
Dust/water protection*2 IP-66 equivalent
Contact point ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm) 901312
Stem diameter Ø8mm Ø15mm
Bearing type Stroke ball bearing
Position-detection method Transmission-type photoelectric linear encoder
Response speed*1 1500mm/sec
Output signal 90° phase difference, differential square wave (RS-422A equivalent);
minimum edge intervals 500 ns for 1 µm model, 250 ns for 0.5 µm model
Signal pitch 4µm 2µm 4µm 2µm 4µm 2µm
Cable length 2m
Power supply Supply voltage +5V (4.8V to 5.2V), ripple voltage 200mV p-p max.
Power consumption Max. 120mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass 250g 290g 380g
Standard accessories Wrench for contact point (538610) Wrench for contact point (210187)
*1: An alarm signal is output when the spindleís movement speed reaches 1500mm/s. If a Mitutoyo counter is used, an error will be displayed.
If the counter is not a Mitutoyo model, contact us regarding the use of alarm-signal output. When the LGF-150L is used, releasing the contact point after pushing it
in may cause an overspeed error depending on the extent to which the contact point is pushed inward.
*2: The IP value is a standard indicating the degree of protection against solid foreign matter and water. Note that the standard may not apply to certain types of liquids.
10
LGB
0.001mm Reading
Reading FEATURES
Differential Square-wave Output • Extremely compact design. Available with an outside
diameter as small as 8mm.
• The small photoelectric linear encoder assures high precision
over the entire stroke range.
• The ball bearings used in the spindle unit ensure superb
durability.
542-222 542-223
542-222H
542-224
Dimensions
Unit: mm
9.2 4.9 9.6
Ø9 Ø9 Ø4.2
18
10.5
Ø9
18 Ø7.9
5 Applicable air hose
25.1 15.9 6.3
Ø12
75
75
9
0
Ø8 - 0.009 Ø14 Ø9.5 - 00.009
34.9 15.4
Ø8 - 00.009 Knurl
24.6
60.1
Clamping nut Ø14
4.9 (thread)
No.200365
60.1
113
23.9 15.4 21.2
7.3
102
L
L=11.5 to 13.0 Ø9.5 - 00.009
50.3
Ø8 - 00.009
(39.3)
Stroke 10.5mm
Clamping nut
82.7
Stroke 10.5mm
or longer
542-230
or longer
L=11.5 to 13.0
(HIROSE) * Connector dimensions are common to all models.
RM12BPG-6P 30 20.4
Individual specifications
Order No. 542-204 542-204H 542-222 542-222H 542-224 542-230 542-223
Stem 8mm diameter, straight stem
Order No. 542-244 542-262 542-262H 542-264 542-270
Stem 9.5mm diameter, straight stem with nut
Measuring range 5mm (.2”) 10mm (.4”)
Accuracy (20°C) 2 µm 1 µm 2 µm 1 µm 2 µm
Measuring Upward ( ) Approx. 0.65N or less Approx. 0.8N or less Approx. 0.6N or less Approx. 0.8N or less
force Horizontal ( ) Approx. 0.6N or less Approx. 0.75N or less Approx. 0.55N or less Approx. 0.75N or less
Downward ( ) Approx. 0.55N or less Approx. 0.7N or less Approx. 0.5N or less Approx. 0.7N or less
Mass 145g (542-204) 145g 150g (542-222) 150g (542-222H) 150g (542-224) 165g (542-230) 165g
160g (542-244) 170g (542-262) 170g (542-262H) 170g (542-264) 170g (542-270)
Air-lifter mechanism Spindle becomes Spindle retreats
None free when air when air is
is supplied supplied
Common specifications
Resolution 0.001mm
Dust/water protection IP-54
Contact point Ø3mm in carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312
Bearing type Stroke ball bearing
Position-detection method Transmission-type photoelectric linear encoder
Response speed 900mm/sec
Output signal/signal pitch 4µm pitch, 90° phase difference, differential square wave (RS-422A equivalent)
Cable length 2m
Power supply Supply voltage: 4.8 to 5.3V, ripple voltage 200mV p-p max.
Power consumption 80mA
Operating enviromment 0°C to 40°C (20%RH to 80%RH, without condensation)
Required air-pressure range 0.3 to 0.4 MPa (3 to 4kg/cm2) (Required only for models equipped with air lifters)
LINEAR GAGE
11
LGE 542-601 542-602
0.005mm Reading
Differential
Differential Square-wave
Square-wave Output
542-604
542-603
The LGE Series Linear Gages are compact electronic gage heads
designed to fit into very tight spaces. Employing linear ball
bearings, the LGE is also highly durable for long life.
FEATURES
• With a rubber boot for use in harsh environments.
• Optional thrust stem and tightening nut facilitate setup of the
LGE linear gage in holes of a plate or fixture.
unit: mm
Applicable air hose (ID Ø2.5)
0.6 (screw top height)
Dimensions
3
3
27.6 27.6
9.1
55
34 55.1 55.1
34.6
34 13.8 19 13.8 19
12.5
18.9
6.5
164.8 (at air supplied)
44.9
128.9
12.5
76.3
15 5.7
105
Ø8 - 0.009 6.5
194.1
0
Ø8 - 0.009
6 Ø15 - 0.018
0
6.5 17
M9.5x0.5
8
299.4
M14x0.5
6
26 (stroke)
0
Ø15 - 0.018
20
6.5
M14x0.5
OPTIONAL ACCESSORIES
Order No. Description
RM12BPG−6P (HIROSE)
51.5 (stroke)
238772 10mm rubber boot (spare) Refer to p.16 Ø18
962504 25mm rubber boot (spare) Refer to p.16
962505 50mm rubber boot (spare) Refer to p.16
39
02ADC730 Ø9.5mm Thrust stem set (for 10mm LGE model) Refer to p.29
02ADC740 Ø18mm Thrust stem set (for 25mm/50mm LGE model) Refer to p.29
Connecting cable 2m
SPECIFICATIONS
Order No. 542-601 542-604 542-602 542-603
Resolution 0.005mm (5µm)
Measuring range 10mm (.4”) 25mm (1”) 50mm (2”)
Accuracy (20°C) 20µm 30µm
Measuring Upward ( ) Approx. 1.2N or less Approx. 4.6N or less Approx. 5.7N or less
force Horizontal ( ) Approx. 1.1N or less Approx. 4.3N or less Approx. 5.3N or less
Downward ( ) Approx. 1.0N or less Approx. 4.0N or less Approx. 4.9N or less
Dust/water protection*1 IP-66 equivalent IP-54 equivalent IP-66 equivalent
Contact point Ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312
Stem diameter Ø8mm Ø15mm
Bearing type Stroke ball bearing
Position-detection method Capacitance-type incremental linear encoder
Response speed*2 Static: 1400mm/s Dynamic: 17.5mm/s
Output signal/signal pitch 20µm pitch, 90° phase difference, differential square wave (RS-422A equivalent)
Output cable length 2m
Power supply Supply voltage 5V (4.8V to 5.2V), ripple voltage 200mV p-p max.
Power consumption 100mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Lifter mechanism None Built-in air lifter*3 None
Mass 200g 220g 250g 300g
Accessories Wrench for contact point (538610) Wrench for contact point (210187)
*1: The IP value given is for water. Note that the unit may not be able to maintain resistance to certain types of liquids.
*2: Static - The maximum movement speed at which no overspeed error occurs.
Dynamic - The maximum movement speed at which measurement by scanning is possible.
*3: The air-supply pressure for 524-604 is 0.3 to 0.4 MPa. The spindle moves forward (becomes free) when air is supplied. Use an air hose with an inside diameter of
2.5mm.
12
LGD
0.01mm/.0005” Reading
Digimatic
Digimatic Code
Code (SPC) Output 575-323/333
FEATURES
• The use of an absolute scale* in the sensor makes it possible
to maintain the origin setting even when the power is
switched off.
• Special linear ball bearings are used for the spindle guide to 575-321/331
ensure a long service life. 575-324/334
• Optional thrust stem and tightening nut facilitate setup of the
LGD linear gage in holes of a plate or fixture.
*: See page 39 for an explanation of the absolute scale.
SPECIFICATIONS
Order No. 575-321 575-331 575-324 575-334 575-322 575-332 575-323 575-333
Resolution 0.01mm .0005” 0.01mm .0005” 0.01mm .0005” 0.01mm .0005”
Measuring range 10mm .4” 10mm .4” 25mm 1” 50mm 2”
Accuracy (20°C) 20µm .001” 20µm .001” 20µm .001” 30µm .0012”
Measuring force Upward ( ) Approx. 1.2N or less Approx. 4.6N or less Approx. 5.7N or less
Horizontal ( ) Approx. 1.1N or less Approx. 4.3N or less Approx. 5.3N or less
Downward ( ) Approx. 1.0N or less Approx. 4.0N or less Approx. 4.9N or less
Dust/water protection*1 IP-66 equivalent IP-54 equivalent IP-66 equivalent
Contact point Ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312
Stem diameter Ø8mm Ø15mm
Bearing type Stroke ball bearing
Position-detection method Capacitance-type absolute linear encoder
Response speed Unlimited; measurement by scanning cannot be performed
Output signal Digimatic output
External input Origin-setting signal (absolute positional origin*3 can be changed externally)
Output cable length 2m
Power supply Supply voltage 5V (4.5V to 5.5V), ripple voltage 200mV p-p max.
Power consumption 20mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Lifter mechanism None Built-in air lifter*2 None
Mass 200g 220g 250g 300g
Standard accessories Wrench for contact point (538610) Wrench for contact point (210187)
*1:The IP value given is for water. Note that the unit may not be able to maintain resistance to certain types of liquids.
*2:The air-supply pressure for 575-324 and 575-334 is 0.3 to 0.4 MPa. The spindle moves forward (becomes free) when air is supplied. Use an air hose with an inside
diameter of 2.5mm.
LINEAR GAGE
13
LGD-M
0.01mm/.0005” Reading
Digimatic Code (SPC) Output
FEATURES
• The use of an absolute scale in the sensor makes it possible to
maintain the origin setting even when the power is cut off.
• The spindle is supported at both ends, improving the
accuracy to 15mm. Dimensions
Unit: mm
( 147.1 )
34
10.5 or longer (stroke)
965275■ * Digimatic Power Supply Unit Refer to p.17
55
*: ■ is left blank or an appropriate suffix (A or E) is inserted, depending on the AC
supply voltage (blank - 100V; A - 120V; E - 240V).
Connecting cable 2m
20
8.6
Ø 8 -0.009
0
37
6.5
12.5
0.6 (screw top height)
SPECIFICATIONS
Order No. 575-325 575-335
Resolution 0.01mm .0005”
Measuring range 10mm .4”
Accuracy (20°C) 15µm .0006”
Measuring force Upward ( ) 2.0N or less
Horizontal ( ) 1.8N or less
Downward ( ) 1.6N or less
Dust/water protection* IP-66 equivalent
Contact point Ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312
Stem diameter Ø8mm
Bearing type Slide-bearing type
Position-detection method Capacitance-type absolute linear encoder
Response speed Unlimited; measurement by scanning cannot be performed
Output signal Digimatic output
External input Origin-setting signal (absolute positional origin can be changed externally)
Output cable length 2m
Power supply Supply voltage: 5V (4.5V to 5.5V), Ripple voltage: 200mV p-p max.
Power consumption 20mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass 182g
Standard accessories Wrench for contact point (538610)
*: The IP value given is for water. Note that the unit may not be able to maintain resistance to certain types of liquids.
14
LGS 100mm
0.01mm/.0005” Reading
Digimatic
Digimatic Code
Code (SPC) Output Stroke Linear Gage
0.001mm Reading
Differential square-wave model
Dimensions Unit: mm
25.5 21.7 542-310
Connecting cable 2m 20 11.4
22
Dimensions Unit: mm
575-301
56.6
132.4
207.7
37
Ø8 - 00.009
14.9
8.6 20
48UNF threads for the
contact point mount.
20
6
16.4 5.3
60 Ø20 - 00.013
OPTIONAL ACCESSORIES
Ø6
Order No. Description
125.3
20 17
36 7 34
SPECIFICATIONS 50
Order No. 575-301 575-302 575-311 575-312
Resolution 0.01mm .0005” SPECIFICATIONS
Measuring range 12mm .5” Order No. 542-310
Direction (UP) plus minus plus minus Resolution 0.001mm
Accuracy (20°C) 0.02mm .001” Measuring range 100mm
Measuring Upward ( ) Approx. 1.96N or less Accuracy (20°C) 3µm
force Horizontal ( ) Approx. 1.67N or less Measuring Upward ( ) Approx. 3.9N or less
Downward ( ) Approx. 1.47N or less force Horizontal ( ) Approx. 2.7N or less
Dust/water protection*1 IP-66 Downward ( ) —
Contact point Ø3mm carbide (mounting Ø5/32” (DIA) steel (4-48UNF) Dust/water protection Not specified
threads: M2.5 (P = 0.45) X 5mm)
Contact point Ø3mm carbide (mounting
Maximum response speed 1600mm/s; measurement by scanning cannot be performed threads: M2.5 (P = 0.45) X
Stem diameter Ø8mm Ø9.52mm (.375”) 5mm)
Bearing type Slide-bearing type Stem diameter 20mm
Position-detection method Capacitance-type incremental linear encoder Bearing type Ball-bearing type
Output signal Digimatic output Position-detection Reflection-type photoelectric
Power supply DC5 to 10V (5mA max.) method linear encoder
Cable length 2m Response speed 400mm/sec.
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation) Output signal 4µm pitch, 90° phase
Mass 170g (including cable) difference, differential square
wave (RS422 equivalent)
*1: The IP value given is for water. Note that the unit may not be able to maintain resistance to certain types of
liquids. Power supply +5V (120mA )
LINEAR GAGE
15
Special Accessories for Gage Head
(See the Operational Guide (page 28 to 31) for mounting bracket, thrust stem and contact point)
Speed controller
• Automatic measurement is possible by using a solenoid valve. 12
E
Dimensions Dimensions LGF-110L Unit: mm
Speed
Unit: mm controller
Ø6
20 Ø12
(85.48)
7
15
15
4.1
12.5 14
6.3
D
6
ø6
C
6.3
12
6.1
7
14
15
15
B (cylinder stroke)
94 to 97
15*1 14
54.4
6.3
64.9
11.4 28
6.3
A (Measuring stroke)
21 11 3 11
4.5
18
70
46
8.8
19
19 6.5
10.5*2
13 at air supply OFF at air supply ON
37
at air supply OFF at air supply ON 64
12 12
6 *1: Cylinder stroke
ø6 *2: Contact point stroke 6
Ø6
Ø15
31
42
18
31
42
20
50
903594 02ADE230 02ADE250/02ADE270
SPECIFICATIONS A B C D E
Order No. 903594 903598 02ADE230 02ADE250 02ADE270 02ADE250 25.5 30 77.6 41.5 (110.5)
Stroke 10mm .4” 10mm 25mm 50mm 02ADE270 51 50 95.9 66.5 (159.5)
Applicable gage model LGS LGF, LGE, LGD
Air supply 0.49MPa 0.2 to 0.4MPa
Air horse to be used Inner diameter : Ø2.5mm
Mass 60g 150g 250g 300g
238772
FEATURES FEATURES
• The distance between a Linear Gage and the Counter can be • Protects the spindle of a Linear Gage from dust.
extended up to 20m by using these cables. • Dedicated for the following models: LGB, LGD, LGE, and
• Cannot be used for LGS, LGD models, and Laser Hologage. LGF.
SPECIFICATIONS SPECIFICATIONS
Order No. Cable length Order No. Applicable Linear Gage
902434 5m 238773 5mm LGB
902433 10m 238772 10mm LGB/LGD/LGE/LGF
902432 20m 02ACA376 10mm LGD-M
962504 25mm LGD/LGE/LGF
962505 50mm LGD/LGE/LGF
238774 mm/inch LGS
16
Special Accessories for Gage Head
(See the Operational Guide (page 28 to 31) for mounting bracket, thrust stem and contact point)
*: ■ is left blank or an
Dimensions appropriate suffix (A or E) is
Unit: mm inserted, depending on the
504
AC supply voltage (blank -
43 100V; A - 120V; E - 240V).
12(stroke)
Ø24
Return-speed adjustment knob
Spindle-lift release for the laser hologage. A sudden drop of the Power-supply unit for models LGD, LGD-M and LGS.
spindle is prevented by the return-speed adjustment knob. Outer dimensions (W x D x H): 62 x 40 x 20 mm
Mass: 50 g
Sample application 1
Dimensions
300
DP-1HS
Sample application 2
110
Ø50
Ø15H7 for
gage setting
270
100
(350)
25
80
Display unit
Measuring stand for Laser Hologage used in high-precision Sample application 2: Use it for setting the absolute origin
measurements. when connecting an absolute-type LGD or LGD-M to a display
Mass: 23 kg unit other than the ES and EV counters.
LINEAR GAGE
17
Linear Gage and Counter Connections
& Comparisons of Counter Functions
KH ES EF EV SD
counter counter counter counter counter
Representative Code No. 542 542 542 542 542 542 542 542 542 542 572 572 572
-051 -053 -055 -057 -059 -060 -061 -062 -063 -064 -001 -021 -052
Applicable gages
0.00001mm Laser Hologage O
0.0001mm Laser Hologage O O
0.0001mm LGB O O
0.0005mm LGF O O O O O
0.001mm LGF O O O O O O O
0.001mm LGB O O O O O O O
0.001/100mm Linear Gage O O O O O O O
0.005mm LGE O O O O O O O
0.01mm LGD/LGD-M O O O O O O
0.01mm LGS O O O O O O
Functions
Number of connectable gages 1 1 1 1 1 1 1 2 2 6 6 1 1 6
Display O O O O O O O O O 1 1 O O 3
Zero set O O O O O O O O O 1 1 O O O
Presetting O O O O O O O O O 1 1 O
Direction switch O O O O O O O O O O O O
GO/±NG indication O O O O O O 1 1 O O
GO/±NG output O O O O O O O O O O
5-stage tolerance display O O O O
5-stage tolerance output O O O O O O
Segment output O O
Inch/mm switch O O O O O O O O O O O 4 O
ABS gage zero set* O O O
ABS/INC gage changeover O O O
Peak hold O O O O O O
Run out (TIR) measurement O O O O O O
Double count O O O O O 5
Calculation function using constant O
Sum/difference calculation O O
External zero set 2 2 2 2 O O O O O O O
External preset O O O O O O O O O O 3
External hold O O O O O O O O O O
External tolerance set O O O O O O 3
External output off O O
External peak-hold cancel O O O O O O
Two coordinate systems switch O
Inter-axial calculation function O O
Output
I/O output BCD output O O O O
Limit output O O O O O O O O
RS-232 output O O O O O O O
Digimatic output O O O O O O O
RS link O O O O O O
(Maximum number of gages) (6) (6) (12) (12) (60) (60)
Power-supply voltage error O O O O O O O O O O
Overspeed error O O O O O O O
Overflow error O O O O O O O O O O O O O
Gage error O O O O O O O O O O O O
System error O O O O
Tolerance setting error O O O O O O O O O O
Communication error O O O O O O
*: The applicable gage type is LGD and LGD-M.
1: When an optional D-EV is connected.
2: Enabled by setting ”O“ via external presetting.
3: When an SD-D2 is connected.
4: Only for models that measure in inches.
5: Uses the calculation function using a constant.
18
Explanation of functions
Shows
MAX the displacement
of radius
MIN as that
of diameter.
TIR (run-out) = Maximum - minimum
1.234 123.456
External control I/O output
Zero set, preset and display hold can be For input/output of external control
controlled from the I/O terminals. signals and tolerance judgment result BCD output
to/from the PLCs or other external The displayed value can be output as
devices. one of I/O signal to a sequence, etc.
RS link function
A maximum of six (EF) or ten (EV) counters can be connected for multi-point measurements using up to 60 channels. EF and EV
counters can be available in the same network (in which case a total of six counters can be connected). Use dedicated RS-link
connecting cable 936937 (1 m), 965014 (2 m) or 02ADD950 (0.5 m). The maximum length of the RS-link connecting cable is
10 m for the entire system.
First counter Last counter
(Output example)
IN OUT IN OUT IN OUT
GN01, + 0001.100CRLF
RS-232C connector RS-232C connector RS-232C connector GN02, + 0001.200CRLF
RS-232C GN03, + 0001.300CRLF
cable
GN04, + 0001.400CRLF
GN05, + 0001.500CRLF
Personal computer GN06, + 0001.600CRLF
GN07, + 0001.700CRLF
GN08, + 0001.800CRLF
Gage number
Measured value
Gage number 01 02 03 04 05 06 07 08......
LINEAR GAGE
19
ES counter
Assembly Type Display Unit
FEATURES
• DIN compatible compact panel-mounting (96 x 48mm). It can
be easily incorporated into each system instrument.
For the gage with differential For the gage with Digimatic
square-wave output. code output.
Unit: mm
Dimensions -V +V OUTPUT
-24V
12
DC0mA
20 -V
0
AD
D40 +V DC IN 12-24V 500mA
02 I
o. EV- 01
e N 0000 MADE IN JAPAN
Cod el No.
Modial PA
N
OU
T
Ser
JA
DE
IN
K Serial 000001
MA LIN Model ES-11 DL
RS Code No. ***-***
IN
INPUT
Approx. 10
44.4 91.4
• Two choices of data output: the BCD data output type (542-
053) and the tolerance judgment output type (542-051) are
137
available.
OPTIONAL ACCESSORIES
Order No. Description
02ADB440 Output connector pulg (with cover) Refer to p.23
6.6
Dimensions of opening
0
48
*: ■■■ is determined by the power-supply voltage specified. Used in
45
20
EF counter
Multi-function Type
FEATURES
• DIN compatible Panel-mounting type and DIN size (144 x Single-display type Double-display type
72mm). It can be easily incorporated into each system (with 1gage input channel) (with 2gage input channels)
instrument.
156.7 Unit: mm
• This counter can be used on a desktop by mounting it on the Dimensions 148.2
144 Showing the
supplied stand leg. 137 AC adapter
connection
72
(3.1)
5.1
27
10°
Rubber foot (provided) 137
11.2
Stand (provided)
138 138 +1
+0.5
Dimensions of opening
68 +0.7
+0.3
(panel mounting)
68
Panel thickness: 1 to 3.2 mm
• The standard RS-232C interface allows easy communication
with an external PC.
• The RS Link function permits multiple EF counters (6 units
maximum) to be connected with daisy chain and data to be OPTIONAL ACCESSORIES
input/output from one channel of the terminal RS-232C
interface. Order No. Description
• The maximum value, minimum value, and TIR (runout) 02ADB440 Output connector pulg (with cover)
measurements are possible. 02ADD950 SPC data output/RS link cable (0.5m)
• The 2-gage input type can perform 2-axis display and make 936937 SPC data output/RS link cable (1m)
addition or subtraction calculations between 2 gages. 965014 SPC data output/RS link cable (2m)
SPECIFICATIONS
Order No. 100V 542-059 542-061 542-060 542-062
(Order number suffix 120V 542-059A 542-061A 542-060A 542-062A
denotes the AC adaptor 220V 542-059D 542-061D 542-060D 542-062D
type equipped.)
240V 542-059E 542-061E 542-060E 542-062E
— 542-059-1*1 542-061-1*1 542-060-1*1 542-062-1*1
Applicable input Differential square-wave
Applicable gage LGB (excluding 0.0001mm resolution),LGF, LGE, 100mm LG LGB (including 0.0001mm resolution),LGF, LGE,
100mm LG, LGH with 0.0001mm resolution*2
Number of gage input 1 2 1 2
(Single-display) (Double-display) (Single-display) (Double-display)
Resolution (Depending on the linear 0.0005mm, 0.001mm, 0.005mm, 0.01mm, 0.0001mm, 0.0005mm, 0.001mm, 0.005mm,0.01mm,
gage type connected) .000005”, .00005”, .0005” .000005”, .00005”, .0005”
Display 8-digit and a negative [-] sign LED (green)
Function Zeroset, preset, limit setting (3 or 5-step), GO/±NG judgement, GO/±NG signal output,
MAX/MIN/TIR (runout) measurement, counting direction switching, double reading, mm/inch switching,
sum/difference calculation of 2 gages (542-061, 542-062 only), output mode selection
Output I/O: Tolerance judgment output (3/5 stages), normal operation output
RS-232C or Digimatic code (selectable): Various measurement data
External Control I/O: Preset, Data hold and Error clear
RS-232C: Displayed value output,MAX/MIN/TIR switching,Zero set,peak value clear, preset value input, tolerance value input and error clear
RS Link Up to six EF counters may be connected via one RS-232C port.(daisy chain)
Error display/output Power-supply voltage error, overspeed error, overflow error, gage error, communication error, and tolerance setting error
Maximum input frequency 1.25MHz (differential square-wave): Max counting Speed : 5MHz
Power supply Via AC adaptor (12 - 24V DC, 700mA (max))
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass (main unit only) 760g 800g 760g 800g
Standard accessories Stand leg (one piece), rubber feet (four pieces), washer for adjusting the mounting plate thickness when securing the plate (six pieces),
DC plug (one piece), AC adapter (excluding model 542-06X-1)
*1: An AC adapter is not required.
*2: Only one LGH may be connected to one AC adapter (provided as a standard accessory). To connect two gages, use a 542-062-1 and a separate power supply (12
to 24V DC, 1A or greater).
LINEAR GAGE
21
EV counter
for Multi-gage System
Multi-function counter
FEATURES
• Up to six gages can be connected to one unit.
• Able to connect up to 10 EV counters to one personal
computer using the RS link function to facilitate the
configuration of a multi-point measurement system
comprising a maximum of 60 gages. For the gage with differential- For the gage with Digimatic
• A range of output modes to choose from; I/O output for square-wave output Code output
tolerance judgment and segment output, BCD data output
and RS-232 output are available.
• Peak-hold measurements are possible for maximum value, Dimensions Unit: mm
minimum value, runout (TIR), etc.
• Able to calculate a sum, average, maximum, minimum,
maximum difference, etc., between gages connected to the
4
RS LINK
IN OUT Err. 5 4
INPUT
F E D C B A
64
72
RS-232C +V -V
IO/BCD
MADE IN JAPAN
DC12-24V
700mA
6
Order No. Description
4 136 4 5 161 5
02ADB440 Output connector pulg (with cover) Refer to p.23
144 16 139 16
02ADD400 D-EV Display Unit Refer to p.23
02ADD950 SPC data output/RS link cable (0.5m) Refer to p.23 6.5
936937 SPC data output/RS link cable (1m) Refer to p.23
4.5
965014 SPC data output/RS link cable (2m) Refer to p.23
02ADD930 Terminal block connection cable Refer to p.23 Interconnecting Affixing an
527428■■■* AC Adaptor Refer to p.23 EV counters EV counter
*: ■■■ is determined according to the specified power-supply voltage. Used in
combination with 02ADD930.
SPECIFICATIONS
Order No. 542-063 542-064
Applicable input Differential square-wave Digimatic Code (SPC)
Applicable gage LGB (excluding 0.0001mm resolution), LGF, LGE, 100mm LG LGD, LGD-M, LGS
Number of gage input 6 6
Resolution (internal) 0.0005mm, 0.001mm, 0.005mm, 0.01mm, 0.001mm*1, 0.01mm, .00005”*,
- no display capability .000005”, .00005”, .0005” .0005”
Function GO/±NG judgment, GO/±NG signal output, MAX/MIN/TIR (runout) measurement, counting direction switching,
mm/inch switching, calculation of sum, average, maximum, minimum and maximum difference between specified axes,
and output-mode selection
Output I/O: Normal operation output and GO/±NG signal (three steps), measurement data (BCD code),
or 21-stage segment output (selectable)
RS-232C: Various measurement data
External Control I/O: Axis designation, preset, data hold, and error clear
RS-232: Displayed value output command, MAX/MIN/TIR switching and peak value clear, zero set, preset value input,
tolerance value input, error clear, and command to output calculated value between specified axes
RS Link Up to 10 EV counters may be connected via a single RS-232 port. (daisy chain)
EV and EF counters can be mixed (in which case a total of six counters can be connected).
Error display/output Power-supply voltage error, overspeed error, overflow error, gage error, communication error, and tolerance setting error
Maximum input frequency 1.25MHz (differential square-wave): Max counting Speed : 5 MHz —
Power supply Terminal block (M3 screws), DC +12 to +24V, 700mA (max.)
Operating temperature 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass (main unit only) 910g 830g
Standard accessories Mounting feet (four pieces), brackets (four pieces), and mounting screws M4 x 8 (eight pieces)
*: Will not be indicated when combined with an LG gage.
22
Options for ES/EF/EV Counters
Dimensions
Unit: mm
GAGE
TIR EV-1
MAX MIN
UNIT +NG
44.4
GO
48
-NG
45+0.8 +0.8
0 x92 0
• The required power supply is DC +12 to +24V, 200mA at the
terminal block.
(AC adapter 02ADD930 and 527428■■■ are available. See 91.4
below.)
SPECIFICATIONS
Number of connectable units One display unit allows external display and setting for one EV counter.
Displayed digits It uses a single sign plus six digits (EV counter operates on eight-digit data internally but displays only the last six digits).
Channel display (also for display of judgment result): 3 (three-color LED)
LED display Measurement mode display (current, maximum, minimum, runout): 2
Status display: 1 (two-color)
Operating switches 4
Switches and their functions Channel switching, measurement mode switching (current value, maximum value, minimum value and runout),
parameter setting, preset, and tolerance setting
Input/output RS Link connectors: 1 in and 1 out.
Error display Overspeed, gage error and others.
Power supply Terminal block (M3 screws), DC +12 to +24V, 200mA
Operating temperature (humidity) range 0°C to 40°C (20%RH to 80%RH, without condensation)
LINEAR GAGE
23
SD Display Unit
Low
Low Cost
Cost Display
Display for
for LGD/LGS
LGD/LGS
SD-D1 SD-D2
FEATURES
• The multi-function type Display Unit (SD-D2) comes with OPTIONAL ACCESSORIES
functions including zero setting, presetting,GO/±NG
judgment, GO/NG analog signal output, and counting Order No. Description
direction switching. 936937 SPC cable for data output (1m) Refer to p.24
• Can be zero set independently of the gage. 965014 SPC cable for data output (2m) Refer to p.24
• Digimatic output function for connection with data 907020 GO/NG signal output cable (2m) Refer to p.26
processing units in the SPC system. 572-041■ * Digimatic Differense/Sa Unit Refer to p.25
• Various equipment is available for configuring a multi-gage 572-052■ * Digimatic Multi Unit Refer to p.25
system. 572-061■ * Digimatic Extension Unit Refer to p.26
264-503■ * Digimatic Mini-Processor DP-1HS Refer to p.26
937179T Foot Switch Refer to p.24
*: The suffix in ■ is determined by the power-supply voltage specified.
SPECIFICATIONS
Digimatic Display Units
Model No. SD-D1 SD-D2
Order No. 100V 572-001 572-011 572-021 572-031
120V 572-001A 572-011A 572-021A 572-031A
220V 572-001D 572-011D 572-021D 572-031D
240V 572-001E 572-011E 572-021E 572-031E
Applicable input Digimatic code (SPC) output
Applicable gage LGD, LGD-M, LGS
Data input port 1
Resolution* 0.001mm, 0.01mm .00005”, .0005”, 0.001mm, 0.01mm .00005”, .0001” .0005”, .001”
0.001mm, 0.01mm 0.001mm, 0.01mm
Display 7-digit green LED (Display digit height: 14.2mm)
Functions Zero setting, SPC data output, Error alarm Zero Setting, Presetting, GO/±NG judgment, Calculation with
constant value, GO/±NG output, Counting direction switching,
Error alarm
Output — Digimatic code (SPC) output, GO/±NG Output
Power supply 9V DC, 500mA (via AC adaptor)
Operating temperature
0°C to 40°C/20%RH to 80%RH (without condensation)
(humidity) range
Dimensions 200 (W) x 120 (D) x 66 (H) mm 236 (W) x 120 (D) x 66 (H) mm
Mass 1.1kg 1.3kg
* Depending on the gage connected.
Note: The SD-D1 Display Unit can only be used with Digimatic gages which have .00005”/0.001mm or .0005”/0.01mm readout.
24
Optional Accessories for SD Display Unit
936937(1m) DP-1HS
965014(2m)
GO/NG lamp
Digimatic Multi-Unit SD-M2
GO/NG Cable
A+B Mode
User's system
A-B Mode
Digimatic Difference/Sum Unit
LINEAR GAGE
25
Optional Accessories for SD Display Unit
GO/NG lamp
SD-E1
Digimatic Indicators
and Linear Gages User's system
SD-D2 Display Unit
with SPC Data Output
(24 Gages maximum)
936937(1m)
DP-1HS 965014(2m)
FEATURES
• Up to four Multi-Units (shown on previous page) can be
connected through the Extension Unit to configure a GO/
±NG judgment system for multiple Digimatic gages (up to 24
gages). The DP-1HS Digimatic Mini-Processor is a powerful, yet
• Max, min, and range measurements can be made for the inexpensive tool for implementing SPC. This compact unit is
connected gages. capable of many functions, including performing calculations
• Tolerance judgment can be triggered using a foot switch for statistical analyses and x-R control charts, generating
(937179T). histograms and individual charts, as well as printing out and
outputting measured data via an RS-232C port.
SPECIFICATIONS
Order No. 572-061 (w/100V AC adaptor) SPECIFICATIONS
572-061A (w/120V AC adaptor)
Order No. 264-503 (w/100V AC adaptor)
572-061D (w/220V AC adaptor)
264-503A (w/120V AC adaptor)
572-061E (w/240-220V AC adaptor)
264-503D (w/220V AC adaptor)
Data input port 4 (allows the connection of up to four SD-M2s) 264-503E (w/240-220V AC adaptor)
Functions • MAX/MIN mesurement Data input port 1 channel for Mitutoyo Digimatic gage
• Range (MAX-MIN) mesurement
Data entry capacity 1000 pieces of data
• GO/±NG judgment (Buzzer and LED)
• GO/±NG signal output Data output port via RS-232C interface
• SPC data output Printer 5X7-dot thermal dot matrix type
• Error alarm Printed items Measurement data, lower limit, upper limit, out-of-
Power supply 9V DC, 500mA (via AC adaptor) tolerance marks, number of data, max./min. value of
Dimensions 236(W) x 120(D) x 66(H) mm data, range, mean value of data, standard deviation,
number of defectives, fraction defective, process
Mass 1.3 kg
capability index, histogram, individual chart, x -R chart,
mean value of subgroup, range of subgroup, number
of subgroup, sample size, part number, date, time,
name of operator
GO/NG Signal Output Cable Number of Characteristic 1
Sample size up to 10
Used to output to external
Power supply 9V DC, 500mA (via AC adaptor/batteries)
devices the GO/NG judgment
results from the SD-D2, Digimatic Dimensions 180(W) x 160(D) x 80.5(H) mm
Multi-Unit and Digimatic Mass 500g
Extension Unit. Cable length: 2m.
See the corresponding technical
explanation on page 37 for pin
No.907020 assignment.
26
Operational Guide and Technical Data
Noise-prevention measure
• Wiring the sensor cable in the same circuit as high-voltage lines or power lines may cause the gage to
malfunction. Be sure to wire the sensor cable separately.
Handling precautions
• This product is a precision measuring instrument. Do not drop or otherwise subject it to impact.
• The spindle (moving unit) of the gage head is connected to the main unit via a spring. Be careful not to pull the
spindle in the extending direction or rotate it with force. Doing so may cause permanent distortion and
damage to the spring.
• The gage is shipped with a standard contact point (901312 or 900032 for the inch version of the LGS)
installed on the spindle. This contact point can be replaced with a different type according to the shape of
workpiece. (See page 31.)
When installing or removing the contact point, place the wrench provided on the catch in order to keep the
spindle from rotating. Then grab the contact point with pliers to install or remove it.
When grabbing the contact point with pliers, insert a piece of felt or other soft cloth to prevent the contact
point from getting scratched.
• Do not set both ends of the stroke as the origin (zero).
Dust/water protection
The dust/water protective construction of all gage heads, excluding the LGH and 100mm LG gages, is equivalent
to IP-66 or IP-54 (DIN40050/IEC529 standards).
• The preamplifiers and counters are not designed to provide dust or water protection. Install them in places
where they will not come in direct contact with water or oil.
• When an extension cable is used, seal the preamplifier connection and connectors completely by making sure
no portion is left exposed.
• IF the cable cover is broken, water or other liquids may enter the gage through the capillary effect, causing
gage failure. When the cable cover is broken, repair it immediately.
• Handle the gage with due caution to make sure that the rubber boots will not be damaged by chipping, etc. If
the rubber boots are damaged, the gage can no longer be protected from dust or water. When damage is
found, repair or replace the boots immediately.
• The rubber material used for the boots and seals does not provide complete protection against coolants and
chemicals, which are becoming increasingly complex in composition. If rubber parts are found to have
deteriorated significantly, contact your nearest Mitutoyo office.
• The gage must not be disassembled, since it will break the seals of various components. Never attempt to
disassemble the gage. Doing so will prevent the gage from functioning to its original specifications.
LINEAR GAGE
27
Operational Guide and Technical Data
wrench.
30
• Precautions
M4x0.7 A' A-A' section
Ø4.5, Ø7.5 depth 4.4
- Exerting undue force between the gage body and stem may
Ø8H7 +0.015
0
damage the gage. Hold the gage body to avoid exerting
excessive force.
- When inserting the gage into the mounting hole, exercise due
Example 2 Unit: mm caution so as not to have the bellows of the gage damaged by
20 15 (9) burrs along the hole, etc.
1 10 7.5
Notch (90° angled
2 against the tap) A (4.5)
Ø10h7 +0.015
15
0
15
30
Ø10h7 -0.015
Ø8h7 +0.0115
0
A-A' section A′
2 M4x0.7
15 (9)
1
28
Operational Guide and Technical Data
LGF LGE/LGD
Ø12
Unit: mm Unit: mm
0
Ø9.5-0.015 (OD, thrust stem)
6
5
5.5~11.5
1
M9.5x0.5
21.5
5.5
14.5
4
9.5
4
45.9
44.9
0
Ø9.5 -0.015 No.200365 Clamping nut
M9.5x0.5
Thrust stem/clamping nut 2
12
12
Ø14
For 10mm LGF
For 10mm LGE/LGD
0
Ø18 -0.018 No.242328 thrust stem
17
9.5 4
10~12.5
8
5
123.4 (LGF 50mm)
82.6 (LGF 25mm)
22.5
84.1(LGE/LGD 25mm)
124.9(LGE/LGD 50mm)
6
M18x1
M18x1 Ø24
For 25/50mm LGF For 25/50mm LGE/LGD
LINEAR GAGE
29
Operational Guide and Technical Data
2-K
A
J
F
D
546343 Ø9.5x8.5
C
F
2-I
H G
C E I H E
B Unit: mm
M K Unit: mm
Part No. 303568 Part No. 303572 B E
A Ø9.5 A Ø9.5 G
A
B 11.5 G 16 B 11.5 F 18 C
2-L
J
D
C 20 H 12 C 40 G 15
H
A
D 30 I 1.75 D 50 H 20
F
E 35 J 40 E 6.5 I Ø4.5 H G F J 2-I
F 7 K Ø4.5 C E I
E 23 35 E 40 60
D
J
F 5 7 F 3 5
A
G 11 16 G 30 40
H G
D 2-G H 8 12 H 15 20
F E L
I 1.5 3.25 I Ø3.4 Ø4.5
Part No. 303574 J 32.5 42.5 J M3x0.5 M3x0.5
Part No. 303570 A Ø9.5 G 10 K 4.5 7.25
A Ø9.5 B 11.5 H 20 L Ø3.4 Ø4.5
B 11.5 E 40 C ø15 I 15 M M3x0.5 M3x0.5
C 60 F 20 D 20 J 35
D 5.5 G Ø4.5 E 40 K Ø4.5
F 8.5 L 1.25
Unit: mm
K B
I Unit: mm
C B
M K
A
A
F
2-L
D
D
For 15 mm diameter stem J
C
I
G
2-J
H G
Unit: mm F E
H E
Reference plane 2-5.5, 9.5 depth 5.5 25
for mounting Part No. 303564 303573 Part No. 303566 303575
Reference plane 15±0.2 2-M5x0.8,
for mounting depth 10 A Ø9.5 Ø9.5 A Ø9.5 Ø9.5
37±0.2
B 9 14.5 B 9 14.5
25
25
50
C 30 40 C 15 15
D 42.5 52.5 D 15 20
12.5 E 4 6 E 25 40
25 M4x0.76 hex-bolt F 15 18 F 8.5 8.5
C2 M4x0.76 hex-bolt (for gage clamping) G 10 15 G 7.5 10
C2
(for gage clamping)
H 15 20 H 10 20
I 4.5 7.25 I 10 15
45
45
23
Plane for bracket Ø15H7 Plane for bracket Ø15H7 L Ø3.4 Ø4.5
mounting (for gage mounting) mounting (for gage mounting) M M3x0.5 M3x0.5
971751 971752
30
Operational Guide and Technical Data
Ø3mm Ball Points Spherical Points 90° Conical Points (Carbide) Flat Points (Carbide)
Unit: mm L Unit: mm Unit: mm Unit: mm
L 9
8
ØD
90°
Ø2
Ø3 A
A
Radius (SR) A A
ØD
Ød
Ruby 120047 M2.5x0.45 Spherical Points (Carbide) 8 Unit: mm
L
8.3* Carbide 902119 M2.5x0.45 Unit: mm
1.7 A
Ø4
1.7
Steel 900986 M2.5x0.45
15 Carbide 120049 M2.5x0.45 D d L Order No. A
ØD
Unit: mm
Ø5
L
D
A
Ø5
R2.5 (.16") A
( ): For inch type
5 Order No. A T W Order No. A
A
L Order No. A 131365 M2.5x0.45 0.4 2 120061 M2.5x0.45
3.97 101184 #4-48UNF 133017 #4-48UNF 0.6 2 120062 M2.5x0.45
L Order No. A 1 4 120063 M2.5x0.45
5 101386 M2.5x0.45
10 101120 M2.5x0.45
10 101118 M2.5x0.45 Unit: mm
12.7 101190 #4-48UNF L
12.7 101185 #4-48UNF
15 137393 M2.5x0.45 Roller Points
Unit: mm
ØD
25 101388 M2.5x0.45
15
Unit: mm
25.4 101187 #4-48UNF L
D L Order No. A
3
10 10 101117 M2.5x0.45 Ø10
Ø5
9
12.7 9.53 101188 #4-48UNF
A 9.53 9.53 101189 #4-48UNF Order No. A
901954 M2.5x0.45
L Order No. A 901991 #4-48UNF
5 101385 M2.5x0.45
7.14 101191 #4-48UNF
LINEAR GAGE
31
Operational Guide and Technical Data
4 5 GND
6 ØB ØB
A
ØB
B
ØB
DOWN PULSE
LGE
Timing chart (normal) ØA
ØA
ØA
ØA ØB
ØB
ØB 4.0µsec 0.5µsec
0.5 to 2msec max. 9.6µsec
ØB
90°
A gage alarm occurs in the following cases:
1µm* 1µm 1µm 1µm • The spindle has moved at a speed exceeding the maximum
(5µm)* (5µm) (5µm) (5µm) response speed.
*Varies depending on the gage. (ex. 0.1µm, 0.5µm). • Noise that may result in a counting error has been detected.
• The internal sensor does not function due to a gage failure.
32
Operational Guide and Technical Data
DATA
3) I/O electrical specifications
• Output terminal format: CK, DATA t1 t2 t3 t4
Nch open drain t8
Maximum output current: 400 µA max. (when Vol = 0.4 V)
Output withstand voltage: -0.3 V to 7 V
ORIG
• Input terminal format: REQ, ORIG
Pull-up CMOS input Absolute origin setting active
Internal power supply voltage: Vdd = 1.35 to 1.65 V t10 Completed
Pull-up resistance: R1 = 10 to 100 KΩ t11
”H” level input voltage: VIH = 1.1 V min.:
“L” level input voltage: VIL = 0.3 V max.
SDP LGD LGS
standard (for reference only)
4) Recommended receiving circuit Symbol min. max. Symbol min. max. Symbol min. max.
*t1 0µs 2sec *t1 30µs 95ms *t1 160µs 85ms
t2 15µs — t2 15µs — t2 150µs 180µs
GAGE side recommended I/F for external device t3 100µs — t3 100µs — t3 150µs 180µs
• CK, DATA Vcc t4 100µs — t4 100µs — t4 300µs 330µs
t5 0µs — t5 0µs — t5 0µs —
R1
*t6 — — *t6 — 100µs *t6 — 100µs
*t7 — — *t7 100µs — *t7 100µs —
R2 C 74HC14,etc.
*t8 — — *t8 — 30ms *t8 — —
e.g. Vcc=5V
Symbol min. max.
• REQ, ORIG *t10 1.5s —
R1, R2=22KΩ±10%
Vdd C=330pF ±20% *t11 — 4s
R1
Tr Note 1: The specifications indicated by an asterisk (*) are applicable only to LGD.
CMOS
All other Digimatic output specifications are common to all models.
Note 2: Read data only when CK is at the “L” level.
Note 3: Do not input REQ signal (fixed at “H”) while the absolute origin is being
Tr= NPN open collector or Nch open drain (2SC2855, etc.) set (during t11).
“H” level output voltage: VOL = 0.2 V max., (IOL = 10 mA. etc.) Note 4: If t5, t6 and t7 are satisfied and REQ is continuously input, an output is
“H” level leak current: IIK = 2 µA max., (at VOH = 5.5 V) obtained from LGD at intervals of approximately 95ms.
Note 5: Start inputting ORIG and REQ after two or three seconds have elapsed
(the estimated time required for internal circuit/sensor to stabilize)
Note: Since the power supply voltages are different between the gage side and following power-on.
the external device side, be sure to use an open collector or open drain circuit.
Do not use CMOS output or the like.
LINEAR GAGE
33
Operational Guide and Technical Data
Display ES counter (limit output type) ES counter (BCD output type) EF Counter
unit 542-051, 542-055 542-053, 542-057 542-059, -060, -061, -062
Pin No. Signal name I/O Description Signal name I/O Description Signal name I/O Description
1 COM —
Common terminal for input/output circuits (connected to internal GND)
2 COM —
3 L1 O A-axis tolerance judgment 1x100 O AL1 O A-axis tolerance judgment
output BCD output output
4 L2 O • Outputs “L” only at terminal 2x100 O Selectable between AL2 O • Outputs “L” only at terminal
5 L3 O used for judgment. 4x100 O positive and negative AL3 O used for judgment.
• Upon occurrence of an error • Upon occurrence of an error
6 L4 O L1, L5 = “L” 8x100 O logic. AL4 O AL1, AL5 = “L”
7 L5 O
L2, L3 and L4 = “H” 1x101 O AL5 O AL2, AL3 and AL4 = “H”
8 — Not used 2x101 O —
9 — 4x101 O — Not used
10 NOM O Outputs “L” when 8x101 O NOM O Outputs “L” when
counting is enabled. counting is enabled
11 — Not used 1x102 O BL1 O B-axis tolerance judgment
output
12 — 2x102 O BL2 O
• Outputs “L” only at terminal
13 — 4x102 O BL3 O used for judgment.
14 — 8x102 O BL4 O • Upon occurrence of an error
BL1, BL5 = “L”
15 — 1x103 O BL5 O BL2, BL3 and BL4 = “H”
16 — 2x103 O —
: : : : : Not used
: : : : :
26 — 8x105 O —
27 — Not used (connected to — —
28 — internal GND) — —
29 — — —
30 — — —
31 — Not used SIGN O Interrupts data output. —
32 — NOM O Outputs “L” when —
counting is enabled.
33 — READY O Outputs “L” when —
BCD data is enabled
34 HOLD I Holds displayed data.*2, *3 HOLD I Holds data, Error clear*4
1
35 P.SET I Displays preset value stored in internal memory.* PA I Execute preset to A-axis.*4
36 — I Not used INH I Terminates data output. PB I Execute preset to B-axis.
*1: With an ES counter, P.SET input is also used as the signal to enable counting when the power is switched on.
*2: With an EF counter, HOLD input is also used as the signal to enable counting when the power is switched on.
*3: With an ES counter, HOLD is used as the data-output request command when data output is executed in the command mode.
*4: It is also used as the signal to clear the peak value being held when peak-hold measurement is performed (input Hold and PA simultaneously).
34
Operational Guide and Technical Data
Interval mode (all CEL output) [EV counter] Command mode (individual CEL output) [EV counter]
Continuously outputs 30ms - 35ms Outputs data of Min. 40ms (Min. 15ms) Min. 15ms
data of all CELs (specified START individual CEL (specified
by SEL1 through 3), by SEL 1 through 3) via HOLD
according to the 5ms - 6ms synchronous control by Data latch for 10 µs only for EV-16P
counterís internal timing. 1.6ms - 2ms HOLD and READY. Max. 40ms 12ms - 15ms
(Max. 15ms) (1.6ms - 2ms)
READY
Tolerance judgment, segment, BCD data *: The figures in ( ) are READY
output values in high- Tolerance judgment, segment, BCD data
CEL1 CEL2 CEL3 CEL4 CEL5 CEL6 speed mode, respectively.
Note: When using the counter in high speed mode or all CELs output, use the
device having 1 ms or less input response time.
LINEAR GAGE
35
Operational Guide and Technical Data (Counter Output)
5)
Operation
Command format Corresponding output
EF counter EV counter
GA**CRLF G#**, +01234.567CRLF Outputs [displayed value] to the RS-232C.
CN**CRLF CH**CRLF Switches display to [current value].
CX**CRLF CH**CRLF Switches display to [maximum value].
CM**CRLF CH**CRLF Switches display to [minimum value].
CW**CRLF CH**CRLF Switches display to [TIR (runout)].
CR**CRLF CH**CRLF Zero set
CL**CRLF CH**CRLF Clears the peak value.
CP**,+01234567CRLF CH**CRLF Inputs the preset value.
CD**,+01234567CRLF CH**CRLF Inputs tolerance S1. Inputs the lower limit of tolerance.
CE**,+01234567CRLF CH***CRLF Inputs tolerance S2. —
CF**,+01234567CRLF CH**CRLF Inputs tolerance S3. —
CG**,+01234567CRLF CH**CRLF Inputs tolerance S4. Inputs the upper limit of tolerance.
CS**CRLF CH**CRLF Cancels error./cancels “stand by for count” status.
CK**CRLF CH**, $CRLF($=0 or 1) — Verifies the hold status.
CT\\CRLF CH\\, +01234.567CRLF — Outputs [Calculated value]
to RS-232C.
1: [**] indicates the channel number of gage between 01 and 99 (00 for all channels).
2: [#] indicates the type of data [N: current value, X: maximum value, M: minimum value, W: TIR (runout)].
3: CRLF means CR (carriage return) and LF (line feed).
4: Inputs preset values and tolerance setting values as a single digit plus eight numerical digits without including a decimal point.
5: When setting tolerances, use CD and CG in this order for three-stage tolerances and CD, CE, CF and CG, in that order, for five-stage tolerances (EF counter).
6: When setting tolerances, use CD and CG, in this order (EV counter).
7: All channels cannot be specified when requesting the data of calculated value or confirming the hold status.
Note 1:The RS-232C communication function is temporarily suspended during key operation (while setting parameters, preset values or tolerances). Commands and
data output will be executed when the system returns to counting-enabled status.
Note 2:To cancel the counting standby status, use CS00CRLF (specification for all channels).
36
Operational Guide and Technical Data (Counter Output)
3 Timing chart
T1 T2 T3 T51 T52
CK
*
DATA
1) Applicable plug:
3) Output/input electrical specifications
TC8050-91-020 by Hoshi Electric or equivalent
• Output
Open collector output: 35V, 50mA (max.)
2) Applicable cable
• Input
907020 (2m): special accessory
Non-polarized contact signal
(see page 26)
Pull-up type, CMOS input (internal voltage 5V)
1
4* O GO “L” when GO O GO/NG GO: "L", NG: "H"
5 — N.C. I TRG GO/NG judgment is executed
upon the input of “L.”
*: GO/NG is determined by the following combinations:
LINEAR GAGE
37
Operational Guide and Technical Data
LGB
542-246
p.9
LGF EF Counter
542-131, 542-132, 542-133 542-059, 542-061
p.10 p.21
LGE
542-601, 542-602, 542-603, 542-604
p.12
EV Counter for multi gages
542-064
3) 0.01mm resolution Types p.22
LGS SD Counter
575-301, 575-302, 575-311, 575-312 572-001, 572-011, 572-021
572-031, 572-052
p.15 p.24
*1: To connect two Laser Hologages to a dual-axis input-type EF counter, use a 542-062-1.
Since the 542-062-1 does not come with an AC adapter, provide a separate power supply (DC 12 to 24V, 12VA).
*2: An external Digimatic power unit is required when connecting an LGD/LGD-M with an SD counter and using the absolute-value function.
38
Operational Guide and Technical Data
A, three-dimensional light
interference is created at the 1P
intersection, and bands of
interference are generated.
The pitch of these bands is
roughly the same as the
wavelength of the light source.
This pitch is set precisely at 0.5 What is the absolute positional origin?
µm with Mitutoyo’s hologram 1/4P
scales. In other words, the
recording of interference bands The absolute positional origin refers to the origin (zero point)
1/
produces a scale of very fine that is maintained even when the power is switched off. The
4P
Li
gh
pitch.
Li
Figure B LGD series gages are equipped with an absolute scale (ABS
gh am
tb
t b (b
e
LINEAR GAGE
39
Specifications are subject to change without notice.
Mitutoyo Corporation
20-1, Sakado 1-chome, Takatsu-ku, Kawasaki-shi,
Kanagawa 213-0012, Japan
Phone (044)813-8230 Fax (044)813-8231
http://www.mitutoyo.co.jp
Printed in Japan
82.400010 (2) CPR