You are on page 1of 3

Applicator Sizing - Flow

Project : CRUDE OIL METERING


Customer: TEXCAL MAHACO EP C.Project No.:
Contact person: AMINULLAH Phone: Fax:
eMail:

TAG : FE-01
Timestamp: --- Review number: ---
Sales order number:

Sizing Sheet
General Parameters
Fluid Oil, Crude 32.6° API - Clean Fluid
State Liquid
Character Clean Atmospheric Pressure 1.0133 bar_a
Abrasiveness Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Fluid type Newtonian

Operating Conditions
minimum nominal maximum
Requested Flow 200 3 000 10 000 USBPD_petro
Pressure 100 100 110 psi_g
Temperature 100 100 110 °F
Density 847.53 847.53 843.98 kg/m3
Viscosity 9.57012 9.57012 8.09568 cP
Vapor Pressure 0.8589 0.8589 1.1681 psi_a
Design pressure (min/max) 100 110 psi_g
Design temp. (min/max) 100 110 °F

Flowmeter : Promass F 500 Generation: 3 Device model: 1


Flow Principle Coriolis (Promass)
Meter Size DN 50
Operating range min. 0   USBPD_petro
Operating range max. 12 467.8   USBPD_petro
Material (sensor) * SS 1.4539 / 904L
Process connection* DN 50 PN40, 1.4404/316/316L, Flansch EN1092-1-B1 Flange
PED category ** : In observance of the selected process conditions and medium, Applicator categorizes this application as PED Art.4.3.
Applicator suggests an instrument without PED option.

  Extended Order Code


Qty Item Description Extended Order Code
1 Flowmeter Promass F 500 8F5B50-**************SAD2SA**+CEDC

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating. The fluids of the Applicator data base are classified to 67/548/EWG.

Print date: 14.04.2020 06:12 AM -1/3-


Applicator®: 11.08.00 / 17.01.01
 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data can be found in the corresponding Operating Instruction
(BA) and Technical Information (TI).
Applicator Sizing - Flow
Project : CRUDE OIL METERING
Customer: TEXCAL MAHACO EP C.Project No.:
Contact person: AMINULLAH Phone: Fax:
eMail:

TAG : FE-01
Timestamp: --- Review number: ---
Sales order number:

Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 200 3 000 10 000 USBPD_petro
Velocity 0.187 2.812 9.372 m/s
Velocity Max. 0.347 5.199 17.33 m/s
Pressure loss 0.02 2.17 18.24 psi
Measurement error Mass*** 0.31 0.1 0.1 %
Reynolds No. 798 11 971 46 972
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Warning(s)

Notice(s)

Message(s)

Print date: 14.04.2020 06:12 AM -2/3-


Applicator®: 11.08.00 / 17.01.01
 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data can be found in the corresponding Operating Instruction
(BA) and Technical Information (TI).
Applicator Sizing - Flow
Project : CRUDE OIL METERING
Customer: TEXCAL MAHACO EP C.Project No.:
Contact person: AMINULLAH Phone: Fax:
eMail:

TAG : FE-01
Timestamp: --- Review number: ---
Sales order number:

Fluid properties sheet


Fluid
Fluid name Oil, Crude 32.6° API - Clean Fluid State Liquid
Chemical formula Calculation standard Supporting Points

Fluid description
Solid content 0 %
Medium character Clean
Abrasiveness Not abrasive
Conductivity Not conductive
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid type Newtonian

Basic fluid parameters


Tc (Critical temperature) 705.5   °F Tm (Melting point) 1.11   °F
Pc (Critical pressure) 3 208.24   psi Tb (Boiling point) 211.7   °F
Heating value 0   kWh/Nm3
Temperature / Viscosity Temperature / Density
Temperature   Viscosity   Temperature   Density  
1    60.08 °F 19.9 cP 1    60.08 °F 862 kg/m3
2    129.9 °F 5.9 cP 2    129.9 °F 837 kg/m3
Temperature / Heat capacity  
Temperature   Thermal capacity  
1    50 °F 0 kJ/(kg*K)
2    212 °F 0 kJ/(kg*K)

Calculated results
Density nom. 847.53   kg/m3 Pressure nom. 100   psi_g
Viscosity nom. 9.57012   cP Temperature nom. 100   °F
Sound velocity nom. 1 790   m/s
Vapor pressure nom. 0.8589   psi_a
Thermal expansion coeff. Beta P 0.0008
Viscosity coefficient AL -7.273
Viscosity coefficient BL 2 963.785
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0133   bar_a Atmospheric pressure 1.0133   bar_a

Print date: 14.04.2020 06:12 AM -3/3-


Applicator®: 11.08.00 / 17.01.01
 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data can be found in the corresponding Operating Instruction
(BA) and Technical Information (TI).

You might also like