LOCATION: ALGERIA EQUIPMENT TITLE: GATHERING HUB CHEMICAL INJ. PACKAGE SERVICE: GATHERING HUB CHEMICAL INJECTION PACKAGE TAG NO: 03ME-3601 NO. REQUIRED: 1 PROJECT: HASSI BIR REKAIZ FIELD DEVELOPMENT PHASE 1 P.O. NO: P.O. DATE: PROJ. NO: TBD ENQUIRY NO: PAGE: 2 OF 6 REV. NOTES 1 1 The package is required to inject Corrosion Inhibitor into the process at Gathering Hub (GH). 2 2 The skid package is envisaged to comprise one 316L stainless steel tank and two API 675 compliant injection pumps. The Tank shall contain 3 one compartment. 4 3 Ideally, the package shall be designed to fit inside a shipping container to simplify transportation to the remote site. Supplier shall advise overall skid 5 dimensions, empty and operating weights, any items to be removed for shipping and a schedule of all package skid edge connections. 6 4 The properties of the chemical given on the following pages are typical. Properties and dosing rates to be confirmed by EPC Contractor. 7 5 The injection pumps shall be double diaphragm pumps with manual stroke adjustment. 8 6 The injection pumps shall be 2 x 100%, one duty and one standby. 9 7 Each pump shall have one head with manual stroke adjustment. 10 8 Deleted 11 9 Deleted 12 10 Deleted 13 11 Tanks shall be supplied with vent. 14 12 Vents shall be suitably protected against the ingress of water, insects and sandstorms. 15 13 Tank working capacity shall be as below. Ullage shall be added to these volumes. 16 Corrosion Inhibitor 4.29 m3 17 14 Liquid level shall be measured in millimetres above the inside of the tank bottom 18 15 Supplier shall complete all missing information on this data sheet. 19 16 The motors on 03ME-3601 shall be supplied with 400 VAC 50 Hz from Temporary Camp. 20 17 Pumps shall comply with Specification for Chemical Injection Metering Pumps HBR-01-GEN-MEC-SPE-0004. 21 18 Package shall comply with Specification for Chemical Injection Packages HBR-01-GEN-MEC-SPE-0003. 22 19 Package supply shall be in accordance with Mechanical Design Basis and Philosophy HBR-01-GEN-MEC-BOD-0001 and Specification for 23 Shop Built Rectangular Storage Tanks HBR-01-GEN-MEC-SPE-0007. This document includes the applicable environmental conditions. 24 20 The package shall be installed on concrete foundations (by others) under an open sided sun shelter (by others). 25 21 Package shall include equipment to allow the flow of chemical from each pump head to be ascertained with an accuracy of +/- 5%. 26 22 Pump discharge relief valve shall be routed back to the chemical storage tank. 27 23 Instrument tubing and fittings are acceptable for chemical injection lines provided they are in accordance with Instrument and Control Philosophy 28 HBR-01-GEN-INS-PHI-0001. 29 24 Tank filling method and any associated additional equipment requirements shall be finalised during detailed design by taking into account the local 30 practices for storage, transportation and loading of chemicals. 31 25 Deleted 32 26 The skid shall be supplied with Local Control Panel and necessary motor starters for Pump On/Off control. 33 27 Structural skid shall incorporate a drip pan sloped to a single skid edge flange connection to collect drips and small leaks. 34 28 EPC Contractor shall provide tag numbers for pumps, tanks and other items within the package. 35 29 The Supplier shall prepare calculations, drawings and all other documents for which he is fully responsible and shall provide the necessary liaison 36 with the DPEM / ARH, if required. 37 30 Refer to Mechanical Design Basis and Philosophy HBR-01-GEN-MEC-BOD-0001. 38 31 Permanent tank on the package shall be fitted with valves, check valves, braided hoses, drip proof male Camlock connections for chemical loading. 39 32 Refer to Instrument and Control Philosophy HBR-01-GEN-INS-PHI-0001, Typical Instrument Hook-up and Installation Details 40 HBR-01-GEN-INS-TYP-0001, and also Instrument Installation and Testing Specification HBR-01-GEN-INS-SPE-0003. 41 33 Requirements for electrical equipment shall follow Electrical Equipment for Mechanical Packages Specification HBR-01-GEN-ELE-SPE-0006. 42 34 Requirements for electrical motors shall follow Data Sheet for LV Motor (Typical) HBR-01-GEN-ELE-DTS-0002. 43 35 Painting requirements shall follow Specification for Painting HBR-01-GEN-MEC-SPE-0006. 44 45 46 47 48 49 50 MECHANICAL DATA SHEET GATHERING HUB CHEMICAL INJECTION PACKAGE CORROSION INHIBITOR STORAGE TANK
LOCATION: ALGERIA EQUIPMENT TITLE: GATHERING HUB CHEMICAL INJ. PACKAGE SERVICE: GATHERING HUB CHEMICAL INJECTION PACKAGE TAG NO: 03ME-3601 NO. REQUIRED: 1 PROJECT: HASSI BIR REKAIZ FIELD DEVELOPMENT PHASE 1 P.O. NO: P.O. DATE: PROJ. NO: TBD ENQUIRY NO: PAGE: 3 OF 6 REV. 1 DESCRIPTION VALUE COMPONENT PART MATERIAL SPECIFICATION 2 DESIGN CODE GEN-MEC-SPE-0007 WALLS 316L stainless steel 3 No. REQUIRED / OPERATING 1 / 1 (note 28) REINFORCING PADS 4 SERVICE (NOTE 4) Corrosion Inhibitor NOZZLE NECK (PIPE) 5 ORIENTATION Rectilinear (PLATE) 6 CORROSIVE COMPOUNDS FORGED FLANGES 7 TEMPERATURE DESIGN ºC -5 / 90 WELDING ELBOW 8 OPER. MAXIMUM ºC INTERNAL COATING None 9 OPER. NORMAL ºC Ambient ANODE PROTECTION None 10 OPER. MINIMUM ºC STIFFENERS 11 AMBIENT (Min/Max) ºC -5 / 55 INTERNAL ATTACHMENTS None 12 PRESSURE DESIGN barg EXTERNAL ATTACHMENTS See NOTE 30 13 OPER. MAXIMUM mbar g EXTERNAL BOLTS See NOTE 30 14 OPER. NORMAL mbar g NUTS See NOTE 30 15 OPER. MINIMUM mbar g GASKETS See NOTE 30 16 DESIGN MINIMUM mbar g INTERNAL BOLTS None 17 NUTS None 18 LIQUID DENSITY@ T & P kg/m3 1010 @ 15.6 C MATERIAL IMPACT TEST REQUIRED No 19 GROSS CAPACITY (Note 13) m3 4.29 CERTIFIED ELEV'D TEMP TEST REQD. No 20 TANK SIZE (L x W x H) m By Supplier 21 LIQUID LEVELS (Note 14) 22 WALL THICKNESS - SHELL By Supplier HIGHHIGH mm None 23 TOP By Supplier HIGH mm By Supplier 24 BOTTOM By Supplier NORMAL mm By Supplier 25 DESIGN FOR FULL HYDROSTATIC HEAD Yes LOW mm By Supplier 26 LOWLOW mm By Supplier 27 NON DESTRUCTIVE TESTING 28 RADIOGRAPHY N/A CONSTRUCTION 29 ULTRASONIC N/A TYPE OF SUPPORT By Supplier 30 MAGNETIC PARTICLE N/A PLATFORM / LADDER CLIPS As required 31 DYE PENETRANT 10% DPI PIPE CLIPS N/A 32 INSULATION SUPPORTS N/A 33 CORROSION ALLOWANCE None MANWAY DAVIT Not required 34 EARTHING BOSS 2 off required 35 INSULATION TYPE None LIFTING LUGS/EYES Required 36 INSULATION THICKNESS N/A NAMEPLATE Required 37 FIREPROOFING None ESTIMATED WEIGHTS 38 PAINTING (EXTERNAL) Per GEN-MEC-SPE-0006 EMPTY kg By Supplier 39 LINING (INTERNAL) None SHIPPING kg By Supplier 40 LADDERS AND HANDRAILS As required OPERATING kg By Supplier 41 FIELD TEST kg By Supplier 42 LEVEL TRANSMITTERS REQUIRED Yes, 2 sets 43 LEVEL GAUGES REQUIRED Yes, 1 set 44 (Magnet) 45 SOUNDS HORN REQUIRED Yes, 1 set 46 47 48 49 50 MECHANICAL DATA SHEET GATHERING HUB CHEMICAL INJECTION PACKAGE CORROSION INHIBITOR INJECTION PUMPS
LOCATION: ALGERIA EQUIPMENT TITLE: GATHERING HUB CHEMICAL INJ. PACKAGE SERVICE: GATHERING HUB CHEMICAL INJECTION PACKAGE TAG NO: 03ME-3601 NO. REQUIRED: 1 PROJECT: HASSI BIR REKAIZ FIELD DEVELOPMENT PHASE 1 P.O. NO: P.O. DATE: PROJ. NO: TBD ENQUIRY NO: PAGE: 4 OF 6 REV. NOTE: INDICATES INFORMATION TO BE COMPLETED BY PURCHASER BY MANUFACTURER 1 FOR Hassi Bir Rekaiz Field Development UNIT DUTY CONTINUOUS 2 SITE Gathering Hub NO. OF PUMPS REQUIRED 2 x 100% (1 Duty / 1 Standby) per package 3 SERVICE Corrosion Inhibitor Injection MODEL SIZE AND TYPE 4 MANUFACTURER SERIAL NO. 5 6 GENERAL 7 NO. MOTOR DRIVEN Two per package OTHER DRIVER TYPE 8 PUMP ITEM NO'S PUMP ITEM NO'S 9 MOTOR ITEM NO'S DRIVER ITEM NO'S GEAR ITEM NO'S 10 MOTOR PROVIDED BY DRIVER PROVIDED BY GEAR PROVIDED BY 11 MOTOR MOUNTED BY DRIVER MOUNTED BY GEAR MOUNTED BY 12 MOTOR DATA SHEET NO. DRIVER DATA SHEET NO. GEAR DATA SHEET NO. 13 14 OPERATING CONDITIONS LIQUID (SEE NOTE 4) 15 CAPACITY @ PT (litres/hr): TYPE OR NAME OF LIQUID Corrosion Inhibitor (CHIMEC 1943 or equiv) 16 NORMAL 2.7 MAX 10.2 PUMPING TEMPERATURE (°C): AMB 17 DISCHARGE PRESSURE(BARG): NORMAL AMB MAX 55 MIN -5 18 NORMAL 50 RELIEF 92 SPECIFIC GRAVITY 1.01 VAP. PRESS.(Bara) 0.001 @ 20°C 19 SUCTION PRESSURE (BAR): SPECIFIC HEAT Cp (kJ/kg °C) 20 MAXIMUM MINIMUM VISCOSITY (Cp) 21 @ 20°C MIN MAX 21 DIFFERENTIAL PRESSURE (BARG): CORROSIVE/EROSIVE AGENTS 22 MAXIMUM MINIMUM CHLORIDE CONCENTRATION (PPM) 23 NPSH AVAILABLE (m) H2S CONCENTRATION (PPM) 24 WITHOUT ACCELERATION HEAD ACTUAL LIQUID TOXIC FLAMMABLE OTHER 25 TURNDOWN RATIO 100% 26 PERFORMANCE SITE AND UTILITY DATA 27 NUMBER OF FEEDS RATED CAPACITY (m³/h) LOCATION INDOOR OUTDOOR 28 NPSH REQUIRED (m) HEATED UNHEATED UNDER ROOF 29 BHP RATED AT RELIEF SETTING ELECTRICAL AREA ZONE 2 GROUP IIB CL T3 30 PLUNGER SPEED (strokes/min) DESIGN MAX WINTERIZATION REQD TROPICALIZATION REQD 31 DIAMETER (mm) LENGTH OF STROKE (mm) SITE DATA 32 PUMP HEAD: RANGE OF AMBIENT TEMPS:MIN/MAX -5 / 55 °C 33 MAXIMUM PRESSURE (BARG) UNUSUAL CONDITIONS 34 HYDRO TEST PRESSURE (BARG) DUST FUMES SALT ATMOSPHERE 35 MAX DISCH PRESS. W/ JOB DRIVER (BARG) OTHER Sandstorms 36 MAX BHP BASIS GEAR STRENGTH UTILITY CONDITIONS - Note 16 37 CONSTRUCTION ELECTRICITY DRIVERS HEATING CONTROL SHUTDOWN 38 SIZE ASME FACING POSITION VOLTAGE 400 VAC 39 CONNECTIONS RATING HERTZ 50 40 SUCTION PHASE 3 41 DISCHARGE COOLING WATER INLET RETURN DESIGN MAX 42 TEMP °C MAX 43 PRESS. (BARG) MIN 44 LIQUID END JACKET REQ'D SOURCE 45 TYPE DIAPHRAGM PLUNGER INSTRUMENT AIR NORM DESIGN 46 DIAPHRAGM DIA (mm) NO REQ. PRESSURE (BARG) 47 48 VALVES/FEED SUCTION DISCHARGE APPLICABLE SPECIFICATIONS: 49 TYPE API 675 POSITIVE DISPLACEMENT PUMPS - CONTROLLED VOLUME 50 NUMBER GOVERNING SPECIFICATION (IF DIFFERENT) GEN-MEC-SPE-0004 MECHANICAL DATA SHEET GATHERING HUB CHEMICAL INJECTION PACKAGE CORROSION INHIBITOR INJECTION PUMPS
LOCATION: ALGERIA EQUIPMENT TITLE: GATHERING HUB CHEMICAL INJ. PACKAGE SERVICE: GATHERING HUB CHEMICAL INJECTION PACKAGE TAG NO: 03ME-3601 NO. REQUIRED: 1 PROJECT: HASSI BIR REKAIZ FIELD DEVELOPMENT PHASE 1 P.O. NO: P.O. DATE: PROJ. NO: TBD ENQUIRY NO: PAGE: 6 OF 6 REV. NOISE DATA REQUIREMENTS 1 2 Normal operating condition, for one unit only: 3 4 5 Table 1 OCTAVE BAND LEVELS 6 Octave Band Mid-frequency (Hz) 63 125 250 500 1k 2k 4k 8k dBA 7 Equipment total 1m SPL 85 8 9 10 11 12 13 14 TO BE COMPLETED BY VENDOR 15 16 The Supplier shall include in the quotation details of any acoustic treatment necessary to meet the requirements given above. All data shall be 17 given for free field conditions after correction for background noise and reverberation effects, for one unit only. 18 19 Maximum noise level from equipment with no special silencing or noise control treatment fitted: 20 21 Table 2 OCTAVE BAND LEVELS 22 Octave Band Mid-frequency (Hz) 63 125 250 500 1k 2k 4k 8k dBA 23 Equipment mean 1m SPL 24 * 1m SPL 25 * 1m SPL 26 * 1m SPL 27 * 1m SPL 28 Equipment total PWL 29 30 Maximum noise level from equipment with proposed noise control treatment fitted, if applicable: 31 32 Table 3 OCTAVE BAND LEVELS 33 Octave Band Mid-frequency (Hz) 63 125 250 500 1k 2k 4k 8k dBA 34 Equipment mean 1m SPL 35 * 1m SPL 36 * 1m SPL 37 * 1m SPL 38 * 1m SPL 39 Equipment total PWL 40 41 REMARKS 42 43 * Denotes that Supplier shall list individual component noise level data, e.g., pump, electric motor, etc. 44 1. All noise levels to be guaranteed. 45 2. Any noise control measures included shall be stated. 46 3. Supplier to forward noise test data, if available. 47 4. Data shall be for equipment 'on load' - please state if otherwise. 48 49 50