Case 1

Flow (m3/hr) 1430


Head (mlc) 40
Slurry SG 1.095
Existing Pump efficiency 82
BKW (Shaft)- When
handling Slurry 208.01 Point conflicting for clause No. 11.2

Case 2
Flow (m3/hr) 1430
Head (mlc) 40
Slurry SG 1
Existing Pump efficiency 82
BKW (Shaft)- When
handling Water 189.97 Complying to clause 11.1

Case 3
Flow (m3/hr) 1430
Head (mlc) 40
Slurry SG 1.095
Existing Pump efficiency 70
BKW (Shaft)- When
handling Water 243.67 Conflict with Point No.28

_x000D_ Confidential - Access limited to Weir personnel or by NDA


#
Case 1
Flow (m3/hr) 892
Head (mlc) 13
Slurry SG 1.002
Existing Pump efficiency 82

BKW (Shaft)- When


handling Slurry 38.59 Point conflicting for clause No. 11.2

Case 2
Flow (m3/hr) 892
Head (mlc) 13
Slurry SG 1
Existing Pump efficiency 82

BKW (Shaft)- When


handling Water 38.51 Complying to clause 11.1

Case 3
Flow (m3/hr) 892
Head (mlc) 13
Slurry SG 1.002
Existing Pump efficiency 70

BKW (Shaft)- When


handling Water 45.20 Conflict with Point No.28