D/WALL GENERAL CHECK


LOCATION
Format No.:QSF/ L&T / CMRL/UG/Q003
DATE
RESULT
Specification Item Remarks
Yes No NA

1) Construction Drawing

2) Preperation of survey points


General 3)Equipment condition for work

4) Material preperation

5) Site clearence for work


1) Is the minimum clear distance between the faces of the
guide wall is the specified diaphragm wall thinkness plus
50mm)
1a) Are the variations from straigth line or specifird profile
exceeding 25 mm in 3mm

Guide Wall 2) Is the trench face of the guide wall on the trench nearest line
to the subsequent main excavation vertical to with in 1:200?

2a) Does the top edge of this guide wall face not varying from a
straigth line or the specified profile by more than +15mm in
3mm and shall be without redhges or abrupt irrrgularities.

3) Proper supporting system

1) Plant condition ( bentonite, silo, de-sander etc. )

2) Bentonite slurry test result


Excavation Work
3) Are the ends of panels vertical to win in tolerance of 1:200 ?

4) Desanding work result


1) Is the logitudinal tolerance of Reinforcement cage head at
the top of the guide wall and measured along the trench is + -
75mm ?
2) Is the vertical tolerance at reinforcement cage head in
relation to the top of the guide wall is+ - 50mm ?
3) Is the lateral tolerance of reinforcement position in the
direction across the width of the wall + - 50mm ?

4) The tolerance of positioning couplers and strater bars for


subsequent structural connections shall be as follows
Is the longitudinal tolerance measured along the trench + -
75mm ?

Is the vertical fixing tolerance + - 50mm at each slab level?


Reinforcement Steel Is the lateral tolerance in the direction across the width of panel
work is + - 50mm ?
5) Is the minimum clear distance between reinforcement bars
greater than 100mm?

6) Condition of reinforcement steel

7) Dimension of cage (Length, space & diameter size)

8) Bending & lapping as per BBS


Dia. No.

9) Couplers Fixed

10) Spacers provided

11) Installation of tremie pipe

12) Concrete type and delivery time


13) Concrete test ( Slump test, Temperature, speciemen
moulds for test)