BEAM 2

BEAM 2
INDICATES
PMO
PRIMARY BEAM 1 ORIENTATION

BEAM 1 1 W
-
BEAM 1 3 W - GREATER THAN OR EQUAL TO 200
LESSER THAN OR EQUAL TO 300 W
- 2T20 GREATER THAN OR EQUAL
BEAM 1 - PRIMARY BEAM TO 150 LESS THAN 200
BEAM 2 - SECONDARY BEAM BEAM 1 - PRIMARY BEAM

LESS THAN OR EQ. TO 1500

LESS THAN OR EQ. TO 1500


LEAD ARCHITECT / PLANNER
BEAM 2 - SECONDARY BEAM B1131 FABRIC
T12-150 U (12mm DIA BARS
BARS VERTICAL)
T10-150 SIDE BARS

PRIMARY BEAM DEEPER THAN CONSTRUCTION JOINT CONSTRUCTION JOINT


LEAD CONSULTANT

SECONDARY BEAM PRIMARY & SECONDARY BEAMS OF


SAME DEPTH

OR EQ. TO 750
LESS THAN
LESS THAN OR EQ. TO 1500
GREATER THAN 750 AND
SLAB REINFORCEMENT
ARCHITECT CONSULTANT

SLAB REINFORCEMENT
SECONDARY BEAM REFT. - T2 PRIMARY BEAM REFT. - T1 SECONDARY BEAM REFT. - T2 PRIMARY BEAM REFT. - T1 ANCHORED OUTSIDE
PRIMARY BEAM REFT. - T1 SECONDARY BEAM REFT. - T2 PRIMARY BEAM REFT. - T1 SECONDARY BEAM REFT. - T2 VERTICAL FABRIC

T10-150 U
BARS

LAP LAP LAP LAP


SECONDARY BEAM REFT.
2T20
PRIMARY BEAM REFT. PRIMARY BEAM REFT. PRIMARY BEAM REFT. -B1 SECONDARY BEAM REFT. - B1
SECONDARY BEAM REFT. SPLICE BAR FOR SECONDARY BEAM-B2
SPLICE BAR FOR SECONDARY BEAM - B2
PRIMARY BEAM REFT. - B1 NOTE:
LOOSE BARS MAY BE UTILISED IN LIEU OF FABRIC SUBJECT TO
THE CONSULTANT'S PRIOR WRITTEN APPROVAL.

SECTION 1 SECTION 2 SECTION 3 SECTION 4


- - - -

BEAM INTERSECTION (NO COLUMN SUPPORT) UPSTAND / DOWNSTAND REINF. (NON STRUCTURAL)
(U.N.O. IN BEAM SCHEDULE)

300 W GREATER THAN OR EQUAL TO 200


LESSER THAN OR EQUAL TO 300 150
2T16 2T16 GREATER THAN OR EQUAL TO 150
LESS THAN 200

GREATER THAN OR EQUAL TO 1000


LAP Rev:

LESS THAN OR EQUAL TO 1600

LESS THAN OR EQUAL TO 1500


B1131 FABRIC OR
LAP 1 (12mm DIA BARS VERTICAL)
LAP

LESS THAN 1000


T16-100 U T12-150 U
BARS BARS
T10-150 SIDE BARS
LAP T12-100 SIDE BARS
ADDITIONAL STIRRUPS
ON EACH SIDE OF STEP
CONSTRUCTION JOINT CONSTRUCTION JOINT CONSTRUCTION JOINT

LAP LAP

01 01.08.19 ISSUED FOR CONSTRUCTION


AT SPAN AT SUPPORT Ta 00 03.05.18 ISSUED FOR CONSTRUCTION
SLAB REINFORCEMENT SLAB REINFORCEMENT SLAB REINFORCEMENT ANCHORED
Seal/Signature
OUTSIDE VERTICAL FABRIC

SWIMMING POOL UPSTAND WALL REINFORCEMENT UPSTAND REINFORCEMENT (NON STRUCTURAL)


(U.N.O. IN BEAM OR WALL SCHEDULE) (U.N.O. IN BEAM SCHEDULE) Project Name
LAP

LAP 1
The Residences

LAP

10 MIN GAP Project Number


LAP
5 EXPANDABLE FILLER
501113
LAP LAP LAP
-
E.J

E.J
PROVIDE EXPANSION JOINT AS PER DETAIL, Description
MAX. DISTANCE BETWEEN JOINTS TO BE 20 METERS

LAP STRUCTURAL:
DEEP SEALANT
AT SUPPORT AT SUPPORT
FLOOR SLAB

STANDARD DETAILS OF BEAMS (SHEET 2)


THK

2 OF 3

NOTE: 1. COLUMN REINFORCEMENT OMITTED FOR CLARITY


SECTION 5
-
Scale

1 : 25 A1

BEAM STEP DETAILS UPSTAND WALL DETAILS


(U.N.O. IN BEAM SCHEDULE)
501113-0000-DRG-WD- ST-008