You are on page 1of 48

Contract No.

: BEA0082005
3D Seismic Acquisition

PARAMETER TEST REPORT

Block BCO III, CHAD

FOR

OPIC Africa Corporation ,Chad Branch

Jan 5, 2012

Crew 8620A, BGP International Chad


CONTENTS

1 Introduction ........................................................................................... 1
2 Test objectives ....................................................................................... 1
3 Test point position ................................................................................. 1
4 Test content ........................................................................................... 2
5 Test analysis .......................................................................................... 7
5.1 Daily Test ........................................................................................................................................... 7
5.2 Drivel Level ...................................................................................................................................... 10
5.3 Sweep Frequency .............................................................................................................................. 17
5.4 Sweep type ........................................................................................................................................ 22
5.5 Num of Vibrators .............................................................................................................................. 31
5.6Taper Test .......................................................................................................................................... 36
5.7 Move up ............................................................................................................................................ 41
6 Conclusion and suggestion.................................................................. 46
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

1 Introduction
Before startup normal production, According to the contract from OPIC, BGP
International CHAD was required to provide OPIC with the recommended test and
schedule for the startup test. Before the experiment, all gathering equipment strictly has
carried on the examination according to the specification, has guaranteed the experiment
authenticity and the accuracy. On Jan 5th 2012, a test for Noise model , drive level,sweep
type and Vibrator sweep parameters has been conducted. During the test, 28 VPs were
recorded in swath 1.

2 Test objectives
The determination best parameter, enhances the main purpose level reflected wave energy.

3 Test point position


Test point Location on the swah1, in the east of BLOCK BCOIII. VP Station number
S5151 2569; Coordinates: (E: 328695.7 N: 990592.1)

Figure 3 TEST POINT POSITION

Page 1 of 56
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

4 Test content

1.Daily Test

FDU, Geophone, Noise, Setup, Get DSD, Radio Similarity, Hardware Similarity

2, Sweep Parameter Test


Source Points: S5151 2569

Geometry:
Receiver Stations: RLine: 2537, 2545, 2553, 2561, 2569, 2577, 2585, 2593, 2601,
2609
Station: 5062-5241
Active Channels: 180*10=1800

Recording Parameter:
Number of Active Channels 1800
Geometry: 180*10
Receiver Stations Interval 30 m
Receiver Line Interval 480m
Recording Length 5s
Sample Rate 2 ms
Low Cut Filter out
Alias Filter 0.75 Nyquist (Minimum Phase)
Notch Filter out
Fixed Gain G2
Tape Copy 2 copies synchronously
Tape Format: IEEE SEG D
Geophone array 12 geophones buried, linear
Array length: Lx =24.75m Ly =0m

Test Items:
1), Drivel Level (7VPs)
Test: 40%, 45%, 50%, 60%, 70%, 75%, 80%
Each VP downloads Get QC and Get DSD
Vibrator Parameter:
Source Array Type Linear
Num of Vibrators 5
Num of sweeps 2
Sweep length 8s
Start Taper 350 ms
End Taper 350 ms
Frequency 8-80Hz
Sweep Type Linear

Page 2 of 56
Vibrators Interval 15m
Array Length 60m
Move up 0m

2), Sweep Frequency (4VPs)


Test: 8-64Hz, 8-72Hz, 8-80Hz, 8-88Hz
Vibrator Parameter:
Source Array Type Linear
Num of Vibrators 5
Num of sweeps 2
Sweep length 8s
Start Taper 350 ms
End Taper 350 ms
Sweep Type Linear
Drive Level 70%
Vibrators Interval 15m
Array Length 60m
Move up 0m

3), Sweep Type (6VPs)


Test: 3dB/OUT, -3dB/OUT, 6dB/OUT, -6dB/OUT,
Random (Drive Level 45%), Random (Drive Level 70%)
Vibrator Parameter:
Source Array Type Linear
Num of Vibrators 2
Num of sweeps 2
Sweep length 8s
Start Taper 350 ms
End Taper 350 ms
Frequency 8-80Hz
Drive Level 45%/70%
Vibrators Interval 15 m
Array Length 30m
Move up 0m

4), Num of Vibrators (4VPs)


Test: 1, 2, 3, 4
Vibrator Parameter:
Source Array Type Linear
Num of sweeps 2
Sweep length 8s
Start Taper 350 ms
End Taper 350 ms
Frequency 8-80Hz
Sweep Type Linear
Drive Level 45%
Vibrators Interval 15 m
Array Length 0/15/30/45m
Move up 0m
5), Taper (4VPs)
Test: (300,300), (350,350), (400,400), (500,500)
Vibrator Parameter:
Source Array Type Linear
Num of Vibrators 5
Num of sweeps 2
Sweep length 8s
Frequency 8-80Hz
Sweep Type Linear
Drive Level 70%
Vibrators Interval 15 m
Array Length 60m
Move up 0m

6), Move-up (1VP)


Test: 7.5m
Vibrator Parameter:
Source Array Type Linear
Num of Vibrators 5
Num of sweeps 2
Sweep length 8s
Start Taper 350 ms
End Taper 350 ms
Frequency 8-80Hz
Sweep Type Linear
Drive Level 70%
Vibrators Interval 15 m
Array Length 67.5m
Move up 7.5m
Vibrator Array

Geophone Array Pattern

12 Buried geophones inline spacing 24.75m


Geophone station interval 2.25m

Vibrator move-up and geophone array


Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

Parameter Test Plan

Page 6 of 56
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

5 Test analysis
5.1 Daily Test

V1Radio Similarity

V2Radio Similarity

Page 7 of 56
V3Radio Similarity

V4Radio Similarity
V5Radio Similarity

V6Radio Similarity
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

5.2 Drivel Level


Along with drivel level's increase, the main purpose level energy obtains strengthens. From monitor qualitative analysis, easy to discover the
obvious difference. And using the KLseis software selection purpose level. When the vibrator drive level uses 80%, the harmonic distortion
increases obviously, reduced in-depth data signal-to-noise ratio. Is dry and hard gradually along with the surface layer land, this kind of
distortion gradually will also increase. So the better drivel level is 70% or 75%.

40% 45% 50% 60% 70% 75% 80%

Figure 5.2.1 Drivel Level BP(8--80)

Page 10 of 56
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

40% 45% 50% 60% 70% 75% 80%

Figure 5.2.2 Drivel Level BP(10--20)

Page 11 of 56
40% 45% 50% 60% 70% 75% 80%

Figure 5.2.3 Drivel Level BP(20--40)


40% 45% 50% 60% 70% 75% 80%

Figure 5.2.4 Drivel Level BP(40--60)


40% 45% 50% 60% 70% 75% 80%

Figure 5.2.5 Drivel Level BP(50+)


Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

Figure 5.2.6 Energy Analysis for Drivel Level

Figure 5.2.7 Frequency Analysis for Drivel Level (1000ms)

Page 15 of 56
Figure 5.2.8 Frequency Analysis for Drivel Level (1900ms)

Figure 5.2.9 S/N for Drivel Level


Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

5.3 Sweep Frequency


Low frequency's reduction has not improved to the data quality, but to the vibrator harm is actually huge. Along with relative frequency
bandwidth's increase, the wave is improved. High frequency enhancement, the data frequency’s bandwidth had not been improved finally. The
60Hz above frequency’s record does not have the effect signal basically. Suggests to use 8-72Hz, the guarantee dominant frequency energy.

8-64Hz 8-72Hz 8-80Hz 8-88Hz 8-64Hz 8-72Hz 8-80Hz 8-88Hz

Figure 5.3.1 Sweep Frequency BP(8-80) Figure 5.3.2 Sweep Frequency BP(10-20)

Page 17 of 56
8-64Hz 8-72Hz 8-80Hz 8-88Hz 8-64Hz 8-72Hz 8-80Hz 8-88Hz

Figure 5.3.3 Sweep Frequency BP(20-40)


Figure 5.3.4 Sweep Frequency BP(40-60)
8-64Hz 8-72Hz 8-80Hz 8-88Hz 8-64Hz 8-72Hz 8-80Hz 8-88Hz

Figure 5.3.5 Sweep Frequency BP(50+) Figure 5.3.6Sweep Frequency BP(60+)


Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

Figure 5.3.7 Energy Analysis for Sweep Frequency

Figure 5.3.8 Frequency Analysis for Sweep Frequency

Page 20 of 56
Figure 5.3.9 S/N for Sweep Frequency
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

5.4 Sweep type


According to the analysis result, the data quality of linear is better than db. For sweep type Random, 2 vibrators and 1vibrator 70% drivel force,
it’s easy to find layer in the low layer.

Linear 6db -6db -3db 3db Linear 6db -6db -3db 3db

Figure 5.4.1 Sweep Type dB BP(8-80) Figure 5.4.2Sweep Type dB BP(10-20)

Page 22 of 56
Linear 6db -6db -3db 3db Linear 6db -6db -3db 3db

Figure 5.4.3 Sweep Type db BP(20-40) Figure 5.4.4 Sweep Type db BP(40-60)
Linear 6db -6db -3db 3db Linear 6db -6db -3db 3db

Figure 5.4.5 Sweep Type db BP(50+) Figure 5.4.6Sweep Type db BP(60+)


2 vibs 2 vibs 1vib 1vib 2 vibs 2 vibs 1vib 1vib

45% 70% 45% 70% 45% 70% 45% 70%

Figure 5.4.7 Sweep Type Random BP(8-80) Figure 5.4.8 Sweep Type Random BP(10-20)
2 vibs 2 vibs 1vib 1vib 2 vibs 2 vibs 1vib 1vib

45% 70% 45% 70% 45% 70% 45% 70%

Figure 5.4.9 Sweep Type Random BP(50+) Figure 5.4.10Sweep Type Random BP(60+)
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

Figure 5.4.11 Energy Analysis for Sweep Type db

Figure 5.4.12 Frequency Analysis for Sweep Type db 600ms

Page 27 of 56
Figure 5.4.13 Frequency Analysis for Sweep Type db 600ms

Figure 5.4.14 S/N Analysis for Sweep Type db


Figure 5.4.15 Energy Analysis for Sweep Type Random

Figure 5.4.16 Frequency Analysis for Sweep Type Random


Figure 5.4.17 Frequency Analysis for Sweep Type Random 1900ms

Figure 5.4.18 S/N Analysis for Sweep Type Random


Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

5.5 Num of Vibrators


Along with Num of vibrators's increase, the main purpose level energy obtains strengthens. From monitor qualitative analysis, easy to discover
the obvious difference. And using the KLseis software selection purpose level. When we use 4 or 5vibrators, it’s difficult to discover the obvious
difference .So the better choice is 5 vibrators..

1 2 3 4 5 1 2 3 4 5

Figure 5.5.1 Num of Vibrators BP(8-80)


Figure 5.5.2 Num of Vibrators BP(10-20)

Page 31 of 56
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

1 2 3 4 5 1 2 3 4 5

Figure 5.5.3 Num of Vibrators BP(20-40)


Figure 5.5.4 Num of Vibrators BP(40-60)

Page 32 of 56
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

1 2 3 4 5 1 2 3 4 5

Figure 5.5.5 Num of Vibrators BP(50+)


Figure 5.5.6Num of Vibrators BP(60+)

Page 33 of 56
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

Figure 5.5.7 Energy Analysis for Num of Vibrators

Figure 5.5.8Frequency Analysis for Num of Vibrators

Page 34 of 56
Figure 5.5.9 S/N for Num of Vibrators
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

5.6Taper Test
From monitor qualitative analysis, and using the KLseis software selection purpose level to analysis energy, frequency, S/N. It’s difficult to
discover the obvious difference. As usual, we suggest use taper 350ms.

300 350 400 500 300 350 400 500

Figure 5.6.1Taper Test BP(8-80) Figure 5.6.2 Taper Test BP(10-20)

Page 36 of 56
300 350 400 500 300 350 400 500

Figure 5.6.3 Taper Test BP(20-40)


Figure 5.6.4 Taper Test BP(40-60)
300 350 400 500 300 350 400 500

Figure 5.6.5 Taper Test BP(50+) Figure 5.6.7 Taper Test BP(60+)
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

Figure 5.6.8 Energy Analysis for Taper Test

Figure 5.6.9 Frequency Analysis for Taper Test

Page 39 of 56
Figure 5.6.9 S/N Analysis for Taper Test
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

5.7 Move up
The fixed-point combination and the moving-up combination did not look that the obvious difference, the use combination suppression noises
effect is not obvious.

Fix-Point Move-up(7.5m) Fix-Point Move-up(7.5m)

Figure 5.7.1 Move-up BP(8-80) Figure 5.7.1 Move-up BP(10-20)

Page 41 of 56
Fix-Point Move-up(7.5m) Fix-Point Move-up(7.5m)

Figure 5.7.4 Move-up BP(40-60)


Figure 5.7.3 Move-up BP(20-40)
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

Fix-Point Move-up(7.5m) Fix-Point Move-up(7.5m)

Figure 5.7.5 Move-up BP(50+) Figure 5.7.6 Move-up BP(60+)

Page 43 of 56
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

Figure 5.7.7 Energy Analysis for Move-up

Figure 5.7.8 Frequency Analysis for Move-up

Page 44 of 56
Figure 5.7.9 S/N Analysis for Move-up
Parameter test Report of OPIC BCOIII 3D Project,Chad, BGP 8620A

6 Conclusion and suggestion

Through the above analysis that original data signal-to-noise ratio compares, after overall
consideration, the vibrator parameter is as follows:
Vibrator number : 5
Number of Sweeps : 2
Sweep Length : 8S
Sweep Frequency : 8 - 72Hz
Drive Level : 70%
Vibration mode : Move up 7.5m between sweeps
Sweep Type : Linear

• random sweeps of 2 vibratos, 45% drive level with 30 to 50m radius, offset
distance to buildings or water well

• random sweeps of 1 Vibrator, 45% drive level with 20 to 30m radius to buildings
or water well, and in the middle of the village.

• 3 Vibrators with 50% force will be used for distances from 50 to 100m.

When 5 Vibrators are employed, the safe offset distance to buildings and water wells must
be maintained at 100m with 70% force.

Page 46 of 56

You might also like