You are on page 1of 37

RONDS Portable Vibration Analyzers

Introduction & Case Study

Anhui Ronds Science & Technology Incorporated Company


Menu

1 RH711 Introduction

2 RH802 Introduction

3 MRS3000 Introduction

4 New Products under development

5 Case Study
1 RH711 Introduction

3
RH711 Main Features

Route Based Inspection

One vibration channel Measurement

Infrared Temperature Measurement

One Plane Balancing

Waveform & Spectrum Analysis

4
RH711 Other Features

Manual input function


i-Button Electronic navigation
Output to computer
RFID card compatible
USB & Wi-Fi communication
Rechargeable lithium battery
CE marking available
Anti-explosion version is available and optional

5
RH711 Main Parameters

1. Frequency range: 2-10KHz


2. Sampling frequency: Maximal 25.6KHz
3.Waveform Length: 1024,2048,4096,8192
4.Lines: 400, 800, 1600, 3200
5.Temperature measuring range: 0~300°C
6.RPM measurement range: 60~10,000RPM
7. Storage Capacity: 1G

6
RH711 Certificates
Ex CE

7
RH711 Full Set

8
2 RH802 Introduction

9
RH802 Main Features

Route Based Inspection

One and two planes balancing

Coast up/Run down

Bump test

Synchronously two channel measurements

Time waveform and spectrum analysis

10
RH802 Other Features

High speed data acquisition


Long time waveform DAQ and analysis
24 bit AD converter, high precision
IP65 design, water and dust proof.
Rechargeable Li-ion battery
I-Button Electronic navigation
Explosion proof version is available and optional
CE marking available

11
RH802 Main Parameters
1. Maximal analysis frequency: 40KHz (if dual channel
:20KHz)
2. Sampling frequency: 256Hz~102.4KHz
3. Lines: 400, 800, 1600, 3200, 6400, 12800
4. Waveform : 1024, 2048, 4096, 8192, 16384, 32768
5. Long time waveform: maximal 20M
6. Dynamic signal range: 96db
7. Working time (continuous): >10hours
8.Storage compacity: 1G

12
RH802 Certificates
Ex CE

13
RH802 Full Set

14
3 MRS3000 Introduction

15
MRS3000
Waveform, Spectrum, Trend

16
MRS3000
Multi-Waveform/Spectrum/Trend

17
MRS3000
User-defined Multi-Waveform/Spectrum

Compare data from same or different measuring points


18
MRS3000-User-defined Trend

Compare trend of different points, or different signal of same point

19
MRS3000-Waterfall

20
MRS3000-Envelope

More flexible in filter range choosing

21
MRS3000--Bearing Database

22
MOS3000

Compatible with online monitoring system MOS3000 if users have online


monitoring products.

23
4 New Products under development

24
New Products Coming--RH712
RH712 Vibration Analyzer

p Temperature/vibration measuring,

p Manual input, photograph and flashlight,

p Waveform analysis

p 24bit A/D conversion

p Maximal 25.6KHz Sampling frequency

p -30 ~ 420(℃)temperature measuring range

p 3.5 inch, 640×480pixel, capacitive touch screen

p 8G storage, maximal extension storage 32G

25
New Product Coming-RH812
RH812 Wireless Vibration Analyzer

p Specialized for vibration analyst, with data display

and basic analysis tools

p 7 inch high definition touch screen, small size, light

weight

p Support route, online and temporary collection

p Wifi/ZigBee wireless communication

p 8G storage,maximal extension storage 32G

p Use wireless sensor

p IP65 protection grade、1.5m impact resistance


26
5 Case Study

27
XX Themal Power 3# Induced Draft Fan
Imbalance and Bearing damage

Induced Draft Fan

Centrifugal fan, overhang,


motor+fluid coupling+fan

Motor:
free end 1H
drive end 2H
Fluid coupling:
Input end 3H、3A
Output end 4H、4A
Fan:
front bearing seat 5H、5V、5A
rear bearing seat 6H、6V、6A

28
XX Themal Power 3# Induced Draft Fan
Imbalance and Bearing damage
Diagnosis Conclusion:

Insufficient rigidity, obvious imbalance


Fan side blade bearing middle-late stage damage,
mainly rolling element damage

Overhaul Suggestion:

Range overhaul plan soon, check blade rotor dust


accumulation or damage
Mainly check fan side blade bearing damage and
change it
29
XX Themal Power 3# Induced Draft Fan
Imbalance and Bearing damage

Parameter

30
XX Themal Power 3# Induced Draft Fan
Imbalance and Bearing damage

Vibration Analysis

Fan blade side vibration is bigger than other position: caused by


overhang fan imbalance
H direction > V direction, due to weak foundation rigidity.

Position H (mm/s) V(mm/s) A(mm/s)


Motor free end 71 23 13
Motor drive end 58 12 13
Fluid coupling near motor side 53 15 18
Fluid coupling near fan side 50 14 12
Fan near coupling side 45 9 13
Fan near blade side 52 20 26

31
XX Themal Power 3# Induced Draft Fan
Imbalance and Bearing damage
Spectrum - Fan Blade Side 6H, 6V, 6A

Clear 1X in 6H, 6V, 6A of fan blade side,H: 48mm/s,A: 23 mm/s

32 Working frequency vibration is obvious, mainly imbalance.


XX Themal Power 3# Induced Draft Fan
Imbalance and Bearing damage
Waveform - 6H, 6V, 6A

Obvious impact in fan blade side 6 position acceleration

33 with high amplitude, 370m/s2.


XX Themal Power 3# Induced Draft Fan
Imbalance and Bearing damage
Envelope - 6V

Clear 71.875Hz and its harmonics in 6V of Fan side;


71.875/12.813=5.6 (2BSF)
34 Close to bearing rolling element forcing frequency
XX Themal Power 3# Induced Draft Fan
Imbalance and Bearing damage

Overhaul Pictures

35
XX Themal Power 3# Induced Draft Fan
Imbalance and Bearing damage

Overhual Feedback Sheet

36
THANKS

安徽容知日新科技股份有限公司
Anhui Ronds Science & Technology Incorporated Company
安徽省合肥市高新区望江西路800号创新产业园B1栋5楼
T: +86 0551-65335195 F: +86 0551-65335196

You might also like