5.6.3 CALCULATION OF THICKNESS BY THE 1-FOOT METHOD

H (m) G CA
D (m) Nominal Sd
Equipment Name Design Liquid Design Corrosion
Tank Diameter
Level Specific Gravity Allowance
Filtered Water Tank 6.48 7.23 1 1 137
UF Water Tank 6.48 7.23 1 1 137
Desalination Tank 6.48 7.23 1 1 137
2nd-stage desa. Tank 6.48 7.23 1 1 137
THOD

St td tt

154 2.60614131 1.42884


154 2.60614131 1.42884
154 2.60614131 1.42884
154 2.60614131 1.42884
5.6.4 Calculation of Thickness by the Variable-Design-Point method

D (m) t(mm) H(m)


Equipment Name Bottom-course corroded L(mm) Maximum Design
Tank Diameter
shell thickness Liquid Level

Filtered Water Tank 6.48 8 160.99689438 7.229


UF Water Tank 6.48 8 160.99689438 7.229
Desalination Tank 6.48 8 160.99689438 7.229
2nd-stage desa. Tank 6.48 8 160.99689438 7.229
method

(L/H) ≤ (1000/6=166.66)

22.2709772278302
22.2709772278302
22.2709772278302
22.2709772278302
Table A-1a TANK CAPACITY

D (m) H (m) C(m^3)


Equipment Name
Diameter of Tank Height of Tank Tank Capacity

Filtered Water Tank 6.48 7.23 238.31861472


UF Water Tank 6.48 7.23 238.31861472
Desalination Tank 6.48 7.23 238.31861472
2nd-stage desa. Tank 6.48 7.23 238.31861472
A.4.1 CALCULATION OF THICKNESS OF SHELL PLATES

H (m) G
D (m) Nominal CA(mm)
Equipment Name Design Design
Tank Diameter Liquid Level Specific Gravity Corrosion Allowance

Filtered Water Tank 6.48 7.23 1 1


UF Water Tank 6.48 7.23 1 1
Desalination Tank 6.48 7.23 1 1
2nd-stage desa. Tank 6.48 7.23 1 1
L PLATES

E t(mm)
Joint Efficiency Nominal
0.85 or 070 Thickness

0.85 2.785325436105
0.85 2.785325436105
0.85 2.785325436105
0.85 2.785325436105