Professional Documents
Culture Documents
ECC DIVISION
PROJECT: Transformer Transportation on Solding Khad Bridge
Refer: IS 800-2007
Material property
Yield strength of the flange f yf = 350 N/mm 2
Yield strength of the web f yw = 350 N/mm 2
Poisson's ratio µ = 0.3
Modulus of elasticity E = 200000 N/mm 2
Partial safety factor
Partial safety factor failure to yield stress γ m0 = 1.1
Dimension of the section
Clear depth of the web between flanges d = 230.0 mm
Thickness of the web tw = 30.0 mm
Breath of Top flange b tf = 260.0 mm
Thickness of Top flange t tf = 15.0 mm
Breath of bottom flange b bf = 260.0 mm
Thickness of bottom flange t bf = 15.0 mm
Analysis results
Chord Compression = 1700 KN
Factored load P (or) N = 2550 kN
Factored Moment at top M zt = 0.01 kN.m
M yt = 0.01 kN.m
Factored Moment at bottom M zb = 180 kN.m
M yb = 0.01 kN.m
Length of column L = 1400 mm
Length Factor Kz = 1
Ky = 1
Effective length KL z = 1400 mm
KL y = 1400 mm
M cr = 5821.92 kN.m
λ LT = 0.29
Imperfection Parameter Ref: Cl 8.2.2 α LT = 0.49
φ LT = 0.56
Bending stress reduction factor χ LT = 0.96
Design bending compressive stress f bd = 304.41 N/mm 2
Desing bending strength of latrerally unsupported M dZ = 411.64 kN.m
as goverened by Latreal torsional buckling
Member subjected to combined axial compression and biaxial bending shall satisfy the
following interaction relationships:
Interaction equation 01
P C my M y Mz
Ref: Cl: 9.3.2.2 Ky K LT = 0.98
Pdy M dy M dz
P C my M y Mz
Ky K LT 1.0
Pdy M dy M dz