You are on page 1of 3

LARSEN & TOUBRO LIMITED

ECC DIVISION
PROJECT: Transformer Transportation on Solding Khad Bridge

STRUCTURE: Design Review of Arch End Frame

Material property
Yield strength of the flange f yf = 350 N/mm 2
Yield strength of the web f yw = 350 N/mm 2
Poisson's ratio µ = 0.3
Modulus of elasticity E = 200000 N/mm 2
Partial safety factor
Partial safety factor failure to yield stress γ m0 = 1.1
Dimension of the section
Clear depth of the web between flanges d = 230.0 mm
Thickness of the web tw = 30.0 mm
Breath of Top flange b tf = 260.0 mm
Thickness of Top flange t tf = 15.0 mm
Breath of bottom flange b bf = 260.0 mm
Thickness of bottom flange t bf = 15.0 mm

# Sensitivity: LNT Construction Internal Use


LARSEN & TOUBRO LIMITED
ECC DIVISION
PROJECT: Transformer Transportation on Solding Khad Bridge

STRUCTURE: Design Review of Arch End Frame


Sectional Property
Area A = 14700 mm 2
Moment of Inertia about major Axis I zz = 147612500 mm 4
Moment of Inertia about minor Axis I yy = 44457500 mm 4
Radius of gyration rz = 100.21 mm
Radius of gyration ry = 54.99 mm

Yield stress ratio


  250 / f y
flange εf = 0.84515425
web εw = 0.84515425
Section Classification
For Bending moment b/t f = compact
Foe direct load d/t w = Semi Compact

Analysis results
Support Load = 2634 KN
Compression = 1520.74061 KN
Factored load P (or) N = 2281.11091 kN
Length of column L = 3000 mm
Length Factor Kz = 1
Ky = 1
Effective length KL z = 3000 mm
KL y = 3000 mm

# Sensitivity: LNT Construction Internal Use


LARSEN & TOUBRO LIMITED
ECC DIVISION
PROJECT: Transformer Transportation on Solding Khad Bridge

STRUCTURE: Design Review of Arch End Frame


Design strength under axial compression
Major Axis
(KL z /r ) = 29.94
Euler buckling stress 2
f cc =p E/(KL/r) 2
f cc = 2202 N/mm 2
non-dimensional effective slenderness ratio  f y f cc λz = 0.399
λ≥0.2 = 0.399
Imperfection factor for buckling class Ref:Table 7 α = 0.34
f=0.5[1+α (λ-0.2)+λ 2 ] = 0.61322919
The design compressive stress f y /  m0 f cd = 294.83 N/mm 2
f cd 
   2  2 
0.5

Buckling resistance of I section P dz = 4334.01 kN


Minor Axis
(KL y /r ) = 54.55
Euler buckling stress 2
f cc =p E /(KL /r ) 2
f cc = 663 N/mm 2
non-dimensional effective slenderness ratio  f y f cc λy = 0.726
λ≥0.2 = 0.726
Imperfection factor for buckling class Ref:Table 7 α = 0.21
f=0.5[1+α (λ-0.2)+λ 2 ] = 0.81910148
The design compressive stress f y /  m0 f cd = 265.68 N/mm 2
f cd 
   2  2 
0.5

Buckling resistance of thesection P dy = 3905.51 kN


Safe

# Sensitivity: LNT Construction Internal Use