Ramagundam OPERATION DEPARTMENT Ref: 09: O&M: OPRN: Date: 13/04/2018 ‘Sub: Review of LM/OGN/OPS/SYST/005/041-Reg LMU/OGN/OPS/SYST/005/041 Revision 2 dated February 2015 on “LONG RETRACTABLE SOOT BLOWER OPERATION” is reviewed and necessary changes are made in the LMI. The — modified LMV/OGN/OPS/SYST/005/041 Revision 3 dated March 2018 along with the sheet containing changes is enclosed. Copy of the LMVOGN/OPS/SYST/005/041 Revision 2 dated February 2015 along with review approval sheets enclosed herewith. Review proposal of LMI is submitted for the kind approval of the ED (R) please. Rae Praveen kumar ML St Manager (0) scmfoy: Weve RVK ND ots Sis Gy: (fa i A ; eye: Su \e a y ED (py! wea ing ond recleasy, AGA LS) Fey uploading 0 Genes 3518 Acm, be me irae, 1 x wis Clause Operation Department Long Retractable Soot Blower Operation LMI/OGN/OPS/SYST/00S/041 LMV/OGN/OPS/SYST/005/041 LMI/OGN/OPSISYST/005/041 SI. | Page No JUNC Nt Rev.2 (Existing) Rev.3 (Revised) 1 | 2 | ap | Wherever the erosion is more the | Deleted (Erosion cannot be checked L | 49 | biowing patter has to be adjusted" _| when unit in servi) Mismateh in SHURIT steam Difference in SH/RH steam 2 | 2 | 4.0(¢) | parameters (LHS/RHS) by more than | parameters (LHS/RHS) by more than | B0degC. 30 deg.C High SH/RH tube temperature High SH/RH tube temperature more 3 | 2 | 4.04) | (580°C) even with spray. than 580 °C) even with spray. (Annexure 1/2 may be referred to, la] i depending on stagel/2/3) 4) 3) 4 New polat (Annexure 1/2 added in this revision) ‘Sub sl nos are mentioned as 5.1,5.2,.. | Sub sl nos are changed as a,b,e..{0 s| 3 | 50 ‘maintain uniformity in document ‘Other precautions to be taken while | Other precautions to be taken while 6 | 3 | 80 | operating LRSB operating LRSB are as mentioned below: '5.2)t is to be ensured that the S.0(b)It is to be ensured that the moisture is properly drained and __| moisture is properly drained and 7) 3 adequate temperature is > 250°C is | adequate Soot blowing temperature is obtained greater than 250 °C is obtained 3.3)Inerease the furnace draft to- | 5.0(@) Maintain a fumace draft at - 20mm so that ID fans can handle 20mmWC to ensure margin in 1D s|3 increase im flue gas volume due to fans to handle fluctuations in blowing furnace pressure due to blowing and impending fall of Clinkers/slags = — __| incase. : | 6)if the power or control supply | 5.0(f) If the power or control supp! | fails the blower should be fails, the blower supply shall be | immediately retracted manually to its | isolated from mcb in Soot blower starting position to avoid damage to. | C&I panel in case of stage 1 and boiler tube or the lance tube. Before | Soot blower MCC in case of stage 2 attempting manual retraction with | and 3.Soot blower may be retracted | hand cranking. Power supply to to its initial starting position by | LSB motor must be quickly hand cranking only after electrical 59 3 | isolated and steam supply to be motive power is cut off, to avoid | throttled to less than Skg/em2 injury (o person retracting at local, | as blower would move in the | direction in which its command is latched. Steam supply may be reduced to value of 5 kse. LRSB blower retraction by hand cranking is done to avoid damage to boiler | | tube and the Lance of LRSB. Page 1 of 2 wo) 4) Operation Department Long Retractable Soot Blower Operation LMI/OGN/OPS/SYST/005/041 1) During LRSB operation, there is | possibility of falling heavy elinkers leading to furnace pressurization, the following care to be taken. 1.Keep the margin in ID fan. 2.If any maintenance work which is ly to beeffected by furnace pressurization (such as impeller replacement, mill maintenance work, ete), concerned maintenance group to be informed. (Responsibility: In charge BM- PP/SCE/UCE) ‘New point uo 4 ‘5.0() Bottom Ash hopper shall be ensured empty during impending BAH flushing, post LRSB. Peep holes at hopper area and APH New Point elevations are checked clear and logged in shift activity log. | (Reponsibility: Incharge BM- PP/AHM/SCE/UCE) yee Praveen kumar M L Sr Manager (0) Page 2 of 2 Ramagundam OPERATION DEPARTMENT LOCATION MANAGEMENT INSTRUCTION LMI/OGN/OPS/SYST/005/041 Rev.3, March 2018 LONG RETRACTABLE SOOT BLOWER OPERATION a Executive Director(R) pare: |S}! Approved for implementation: .. RAMAGUNDAM SUPER THERMAL POWER STATION Ramagundam OPERATION DEPARTMENT LMI APPROVAL DOCUMENT 1. | tm oF pocument roe 2 ee, | ee ee 3. | ORIGINAL /REF.DOCUMENT OGN/OPS/SYST/005 4. | PREPARED BY yor Signature: _ Shri Praveen Kumar M L, Sr. Manager (O) CHECKED BY _—— ty : cs. a AGM (Operation) AGM (BM-PP) 5. | REVIEWED BY Shri Ravindra, GM fon. © NS 6. | APPROVED BY Signature: Aw q! « Shri D. K. Dubey, EDR) DATE OF ISSUE. - INDEX LIST Enelosed DISTRIBUTION LIST ‘As per Master Distribution List Ramagundam OPERATION DEPARTMENT LMI Master Distribution List LONG RETRACTABLE SOOT BLOWER 1 | Title of LM OPERATION a) Document Code : LMI/OGN/OPS/SYST/005/041 2 a jon/Issue No. & REV3, March, 2018 | 3__| Original/Ref. document OGN/OPS/SYST/005 Master Distribution List 1 | Master Copy EEMG 2 | Copy 1 of 6 HOD concerned department | 3 Copy 2 of 6 GM@&M) 4 | Copy3 of 6 - GM™) 5 Copy 4 of 6 GM(FM) 6 Copy 5 of 6 _GM(O) T__| Copy 6 of 6 GM(TS) vo ot igy Raga LMU/OGN/OPS/SYST/005/041 REV.3, March 2018 SL.NO. CONTENTS PAGE NO. 1, | Introduetion 2 2. | Superseded Documents 2 3. | Scope 2 4, | Frequency of operation 2 5. | Precautions 3 6. | Responsibility 5 7. | Review 3 8. | Annexure-1 6 9, | Annexure-2 6 ue t (Praveen Kumar M L, Sr. Manager (0) | Sulesh, ©) Ll Prepared b: [ ‘Checked by Page 1 of 6 10 20 3.0 4.0 Operation Department Ram Long Retractable Soot Blower Operation fagundam ‘LMI/OGN/OPS/SYST/005/041 REV.3, March 2018 INTRODUCTION: In fossil fuel fired boilers, keeping the fire side clean brings immense improvement in boiler efficiency. For this, on line cleaning of heat absorbing surfaces is done by soot blowers. Cleaning the fire side not only improves heat transfer, but also clears the blocks that can restrict flow, cause tube erosion due to high local velocities and result in load limitations. SUPERSEDED DOCUMENTS: LMMVOGN/OPS/SYST/005/041, 2000 LMM/OGN/OPS/SYST/005/041, Rev 1, 2011 LMV/OGN/OPS/SYST/005/041, Rev 2, 2015, SCOPE: ‘This LMI provides guidelines regarding frequency of operating LRSB, emergency operation of LRSB, boiler parameters to be monitored before and after soot blowing and records to be maintained. FREQUENCY OF OPERATING LRSB: LRSB is to be operated as per requirements, indicated by following parameters: a) Increase in SH/RH Economizer flue gas DP by SmmWC than normal or APH inlet flue gas temperature increase by 10°C.(stage | units) b) Increase in ID fans inlet pressure or ESP inlet pressure by 1mm\WC than normal value. ©) Difference in SH/RH steam parameters (LHS/RHS) by more than 30°C d) High SH/RH tube temperature more than 580°C, even with attemperation spray. e) Ash accumulation in the furnace is also indicated by sudden fluctuation in furnace pressure. Falling of clinkers in normal unit operating conditions. 2 2) As per PADO recommendations (unit 7). No Fite Praveen Kumar ML, Sr. Manager (O) Suresh, AGM (Oy Prepared by Checked by Page 2 of 6 | 4d 5.0 ae | eet Praveen Kumar M L, Sr. suresh, A‘ i d) Operation Department R Long Retractable Soot Blower Operation jagundam LMIOGN/OPS/SYST/005/041 REVS, March 2018 The following parameters are to be monitored before and after LRSB operation (Annexure 1 for stage I and Annexure 2 for stage 2&3 may be referred to) a) Unit Load. b) Date and time of LRSB Operation. ©) Number of blowers operated. Reason for non opers 4) Problems encountered while operating the LRSB. ©) Blowing steam pressure and temperature. £) Boiler gas outlet temperature at APH inlet. 2) Furnace gas DP across SH, RH coils and economizer. h) SH/RH attemperation flows. i) SH/RH metal temperature (MMT), PRECAUTIONS: Other precautions to be taken while operating LRSB are as mentioned below: of a particular blower. Its preferable to keep the concerned maintenance personnel with required tools while carrying out soot blowing operation. Its to be ensured that the moisture is properly drained and adequate Soot blowing temperature is greater than 250°C is obtained. Maintain a furnace draft at -20mmWC so as to ensure margin in ID fans to handle fluctuations in furnace pressure due to blowing and impending fall of Clinkers/slag incase. During LRSB operation, oil guns support can be taken in stagel units for flame stability while blowing gooseneck area. Correct steam pressure is maintained after puppet valve at 10Ksc. It is to be checked every three months after boiler overhaul and puppet valve is to be adjusted to get the required pressure. (Responsibility: AGM-BM-PP/AGM (0)) If the power or control supply fails, the blower supply shall be isolated from MCB in Soot blower C&I panel in case of stage 1 and Soot blower MCC in case of stage 2 and 3. Soot blower may be retracted to its initial starting position by hand cranking, only after electrical motive power is cut off. Steam supply may be reduced to value of 5 ksc. LRSB blower retraction by hand cranking is to be done to avoid damage to boiler tube and the lance of LRSB. A minimum flow at Sksc is maintained to ensure minimum cooling till such efforts are done to retract it to home position. (Responsibility: AGM-BM-PP/ SCE-Operation) Unit loads shall be maintained at rated capacity to minimize MS pressure fluctuations affecting load and flame stability. (LRSB operation shall not be carried out below 80% of unit capacity for better flame stability during operation.) (Responsibility: SCE-Operation/Unit Controller) Prepared by _ Checked by —_ Page 3 of 6 | Operation Department Ram FA Long Retractable Soot Blower Operation ragundat LMV/OGN/OPS/SYST/005/041 REV.3, March 2018 g) Ensure that all blowers are completely retracted and supply is isolated. (Responsibility: SCE/UCE) h) During LRSB operation, there is a possibility of falling heavy clinkers leading to furnace pressurization, the following care to be taken. 1. Keep the margin in ID fan. 2. Ifany maintenance work which is likely to be effected by furnace pressurization (such as impeller replacement, mill maintenance work, etc), concerned maintenance group to be informed. (Responsibility: In charge BM-PP/SCE/UCE) i) Bottom Ash hopper shall be ensured empty post LRSB. Peep holes at hopper area and APH elevations are checked clear and logged in shift activity log. (Cross reference to LMI: LMUOGN/OPS/SYST/001/056 on BAH ash build up ) (Responsibility: In charge BM-PP/AHM/SCE/UCE) 6.0 RESPONSIBILITY: ‘The availabil ry of hand crank and a dedicated group of operators trained on LRSB operation and maintenance as per the requirements of this LMI. (Responsibility: AGM (BM-PP)/AGM (O)/AGM (EM)) ‘The records pertaining to LRSB should be reviewed by HOD (operation) at least once in a month, 7.0 REVIE! This document shall be reviewed periodically once in two years by HOD (0). Prepared by ‘Checked by l Page 4 of 6 Operation Department Ram: t Long Retractable Soot Blower Operation fagundam LMV/OGN/OPS/SYST/005/041 REV.3, March 2018 Annexure:1 Stage 1 (200MW) LRSB Monitoring sheet = | Gr3 blowers: Unit no Date Gr4 blowers: No of Blowers Operate ‘Starting Timi LRSB not operated: Finishing Time: Parameters before and after LRSB Opera 7 S.NO PARAMETERS UNITS BEFORE | AFTER 1 | Load MW 2 | Millsin Service | 3 | Additional air registers openifany | 4 | SH damper position open 5 | RH damper posi open 6 | AiriCoal flow TPH 7 | Flue gas O2UR % ~ 8 | SHI/SH2/RH attemperation TPH | - 9 MS/HRH steam temp( Boiler O/L) °C 10 | CRH DESH IL/OL Temp(LHS) °C “| | 11) CRHDESH IL/OL Temp(RHS) °C - 12 | SHMMTand Coil no 13 | RHMMTand Coil no - 14 | APH A Flue gas in/out temp =; 15 | APH B Flue gas in/out temp °C 16 | Flue gas DP across ECORH/SH | ~— mmWC 17 | Soot blowing steam pr/temp: Kse/ °C | 18 | Flue Gas Temperature(L/R) 5c 19 | CO levels (L/R) ~~ ppm! Remarks/defeets (if any): bear Kumar ML, Te "Manager (O) PRR ScnO Prepared by Checked b Page 50f6 | Operation Department magi Long Retractable Soot Blower Operation ereomen LMV/OGN/OPS/SYST/005/041 REV.3, March 2018 Signature: Annexure:2 Stage 2/3 (500MW) LRSB monitoring sheet Unit no ‘No of Blowers Operated: Date | | Starting Ti LRSB not operated: Finishing Time: - Parameters before and after LRSB Operation: S.NO PARAMETERS ‘UNITS BEFORE AFTER | 1 | Load - MW | 2 | Mills in Service 3 | Aur/Coal flow TPH 4 | Flue gas 02 UR % 3 | SH/RHattemperation TPH 6 MS/HRH steam temp( Boiler O/L) °C a 7 __|SH MMT and Coil no [8 |RHMMT and Coil no | 9 | PAPH A Flue gas in/out temp °C 10 | PAPH B Flue gas in/out temp °C 11 | SAPH A Flue gas in/out temp °C 12 |SAPH BFluegasin/outtemp [| °C 13 | ECO flue gas in/out temp °C 14 _ | Soot blowing steam pr/temp: Kse/ °C 15 | Flue Gas Temperature(L/R) °C Remarks/defeets (iff any): Signature: = n ) CORY Praveen Kumar M L, Sr. Manager (O) "P Suresh, AGM (O) : { Prepared b Checked by Page 6 of 6

You might also like