Professional Documents
Culture Documents
Paladin Tools ®
LAN & Telecom Cable Testing Kit Operating Instructions LAN & Telecom Cable Testing Kit
1573 1573
NOTES: Testing Cables for Pin-out Wiring Configuration (Cable Mapping): Features and Benefits
connectool Inc. - USA • Support: 800.272.8665 • Int’l 001.804.550.1121 • web: paladin-tools.com • 06/05 connectool Inc. - USA • Support: 800.272.8665 • Int’l 001.804.550.1121 • web: paladin-tools.com • 06/05
Paladin Tools ®
Paladin Tools ®
LAN & Telecom Cable Testing Kit LAN & Telecom Cable Testing Kit
1573 1573
NOTES: 6. For best results, use “Dual” for balanced line toning, and “Single” for NOTES: Testing Continuity of Lines and Loads:
unbalanced line toning. Press and hold the “TONE” button to change tone
patterns. DO NOT USE ON LIVE CIRCUITS
7. Use the tone probe to detect tone signals along the cable length. Press and ENSURE THE TONE GENERATOR IS TURNED OFF
hold the “TRACE” button to activate the tone probe. The “Power” light will
turn on when button is depressed. Use the “volume” adjustment located on 1. Install the alligator clip cable into the top of the tone generator.
the side of the tone probe to set volume to desired level.
2. Set the “tlk, cont, line/tone” slide switch located on the side of the tone
8. For quiet operation, insert standard 3.5 mm head phones into the headset
generator to the “cont” position.
socket located on the side of the probe.
3. Connect the alligator clip test leads to the ends of the cable or across the
9. Set “tlk, cont, line/tone” switch on side of tone generator to the “cont”
position when storing. Leaving the switch in the “line/tone” position will
load to be tested.
not cause any battery drainage unless the metal tips of the red and black 4. If the DC resistance (continuity) of the cable or load is 12000Ω (12KΩ) or
alligator clips touch. less, the “Reverse” light will turn on indicating a path of continuity.
5. Set the “tlk, cont, line/tone” switch on side of tone generator to the “cont”
Testing phone circuit polarity: position when storing. Leaving the switch in the “line/tone” position will
not cause any battery drainage unless the metal tips of the red and black
WARNING! LIVE CIRCUIT TESTING - USE CAUTION alligator clips touch.
ENSURE THE TONE GENERATOR IS TURNED OFF
Continuity Testing
Continuity Testing Continuity Testing
Continuity Testing
1. For testing directly into RJ11 wall jacks, use the RJ11 patch cord wired 1-to-1 Good Continuity
Good Continuity No Continuity/High
No Continuity/HighRes.
Res.
connection.Connect the RJ11 patch cord into the top of the tone generator in the Rev
Reverse Reverse
Rev
Examples: Test Results Norm
RJ11 socket. (Proceed to Step 4). Normal Norm
Normal
and Indications
2. For testing telephone boxes, discrete wire connections or open contact Dual
Dual Dual
Dual
connections, install the alligator clip cable provided into the top of the tone Single
Single Single
Single
connectool Inc. - USA • Support: 800.272.8665 • Int’l 001.804.550.1121 • web: paladin-tools.com • 06/05 connectool Inc. - USA • Support: 800.272.8665 • Int’l 001.804.550.1121 • web: paladin-tools.com • 06/05