You are on page 1of 3

SAUDI ARAMCO CSD/ME&CCD/MEU

CONSULTING SERVICES DEPARTMENT Log # MS- 13535


ME&CCD/MEU
Procedure Review Sheet

REVIEW STATUS Status Contractor / Vendor EMAS (Larsen & Toubro)


1 WPS / Rev. As Listed
By Malcolm Setchfield
: Date Procedure Type Welding Procedure Specifications (WPS)
13/7/2017 B.I. / Contract no. 6600035803 (OOK) / BI No. 10-01902
RETURN TO: P.O. Number
Saad Al-Wahaib, Project Engineer Equipment No. or
Fadhili Gas Program, Rm. 18, Floor 9, Petrofac House, Line Cl. / Grp # See Below
Tower 2, Al-Khan Road, Shajah, UAE Service Conditions
Design Code: Qualification Code
B31.1 B31.8 API 620 ASME Sec IX Sour
Incoming references:
B31.3 Sec.8 D1 API 650 API 1104
LTHE-EMAS/SA/HASBAH-II/OOK/D/C/09667 Hrdn.
B31.4 Sec.8 D2 API RP2A AWS D1.1
Previous log reference: CSD/ME&CCD/MEU Log # PWHT
Welding Process(es) Transfer Mode
n/a SMAW GMAW SAW Impacts
NA
GTAW FCAW ESW MDMT
REVIEW STATUS DEFINITIONS:
1 - APPROVED P No. Gr. To P No. Gr.
2 - APPROVED AS NOTED. FABRICATION MAY PROCEED Filler Metal
3 - APPROVED AS NOTED, FABRICATION MAY PROCEED, PQR No./Rev.
SUBMIT CORRECTED COPY
4 - NOT APPROVED; CORRECT AND RESUBMIT PQR
5 - REVIEW NOT REQUIRED

Note: Fabrication of Jacket Legs, Deck Column, Piles, Crane Pedestal Column, Primary & Secondary Bracings

The following WPS's were all previously approved by Saudi Aramco CSD at Status 2, however, it is noted that L &
T have revised these WPS's and the following are approved for the given application. All previous approvals for the
following WPS's shall be discarded in favour of this approval.

L & T shall note that a CSD Status 1 or 2 is approved and does not require re-submission UNLESS for a technical
reason changes have to be made to the WPS.

LT-MFY-HASBAH-II-STR-04 Rev B LT-MFY-HASBAH-II-STR-43 Rev B


LT-MFY-HASBAH-II-STR-05 Rev B LT-MFY-HASBAH-II-STR-106 Rev B
LT-MFY-HASBAH-II-STR-10 Rev B LT-MFY-HASBAH-II-STR-77 Rev B
LT-MFY-HASBAH-II-STR-11 Rev B LT-MFY-HASBAH-II-STR-80 Rev B
LT-MFY-HASBAH-II-STR-12 Rev B LT-MFY-HASBAH-II-STR-103 Rev B
LT-MFY-HASBAH-II-STR-13 Rev B LT-MFY-HASBAH-II-STR-104 Rev B
LT-MFY-HASBAH-II-STR-36 Rev B LT-MFY-HASBAH-II-STR-105 Rev B
LT-MFY-HASBAH-II-STR-38 Rev B
LT-MFY-HASBAH-II-STR-39 Rev B

THE REFERENCED PROCEDURE(S) HAS BEEN REVIEWED AND EVALUATED IN CONJUNCTION WITH SUPPORTING DOCUMENTATION. UTILIZATION OF THIS PROCEDURE INDICATES THAT THE
MANUFACTURER OR CONTRACTOR CERTIFIES THAT THE STATEMENTS AND DATA IN THIS DOCUMENTATION ARE CORRECT. HE ASSERTS THE TEST WELDS WERE PREPARED, WELDED,
TESTED, AND MET THE REQUIREMENTS AS INDICATED AND IN ACCORDANCE WITH THE APPLICABLE CODE AND SAUDI ARAMCO STANDARDS AND SPECIFICATIONS

You might also like