Distribution Manifold
J6 Series
■ Extruded stainless steel body rated for 6 000 psig (414 bar)
working pressure
■ Compact, versatile manifold for gas and liquid
applications
■ Fewer potential leak points than conventional distribution
manifolds
■ Four to eighteen needle valves / outlet connections
■ Mounting holes through the manifold to reduce stress
on the piping system
Options
■ Flanged inlet connections available
■ Anti-tamper feature available
■ Bleed/drain valve available
■ Hydrostatic test certificates complete with full chemical and physical
material certifications available
For these and other options and accessories, contact your independent
Swagelok sales and service representative.
Pressure-Temperature Ratings Materials of Construction
End Connections Temperature Working Pressure Component Material
in. °F (°C) psig (bar) Body
316 / 316L SS / A479
PTFE Seals Bonnet
200 (93) 6000 (414)
S17400 SS / A564
1/2 and 3/4 Needle
400 (204) 4000 (275) Condition H1150D
200 (93) 3000 (206) Packing
1 PTFE or graphite
400 (204) 2000 (137) Bonnet seals
Graphite Seals Gland nut
200 (93) 6000 (414) Shroud
1/2 and 3/4
850 (454) 3000 (206) Gland
200 (93) 3000 (206) Handle 316 SS
1
850 (454) 1500 (103) Handle locknut
Stem Wetted components
listed in italics.
Testing Locking pin
Every valve is hydrostatically tested at ambient temperature.
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
4 5.35 (136)
0.63 6 7.72 (196)
(16.0)
8 10.1 (256)
(140)
5.51
10 12.4 (316)
12 14.8 (376)
14 17.2 (436)
16 19.5 (496)
connection
NPT inlet
Ordering Information
J S 4N 2N A T - 10
Basic Series Number
Total Number of Outlet Connections (Valves)
Body Material Specify a number from 4 to 18
316 / 316L stainless steel Example: 10 = 10 valve/outlet connections and valves
Inlet Connection Handle
4N = 1/2 in. female NPT Bar handle
6N = 3/4 in. female NPT
8N = 1 in. female NPT Packing and Bonnet Seal Material
A = PTFE C = Graphite
Safe Product Selection Caution: Do not mix or interchange parts with those of
When selecting a product, the total system design must other manufacturers.
be considered to ensure safe, trouble-free performance.
Function, material compatibility, adequate ratings, Swagelok—TM Swagelok Company
© 2004 Swagelok Company
proper installation, operation, and maintenance are the Printed in U.S.A., GLL
responsibilities of the system designer and user. May 2004, R1
MS-02-214