NEMA Ratings and IP Equivalency


Chart

Protection  Protection
NEMA IP Against Against
Rating Equivalent NEMA De nition Solids Liquids

1 IP10 Enclosures 1= 0 = Not


constructed for Protected Protected
indoor use to against
provide a degree solid
of protection to foreign
personnel against objects of
incidental contact 50mm in
with the enclosed diameter
equipment and to and
provide a degree greater
of protection
against falling dirt

2 IP11 Enclosures 1= 1=
constructed for Protected Protected
indoor used to against against
provide a degree solid vertically
of protection to foreign falling
personnel against objects of water
incidental contact 50mm in drops
with the enclosed diameter
equipment, to and
provide a degree greater
of protection
against falling
dirt, and to
provide a degree
of protection
against dripping
and light
splashing of
liquids

https://www.siemon.com/en/home/support/compliance/nema-ratings-and-ip-equivalents 1/8
4/21/2020 NEMA Ratings and IP Equivalency Chart

Protection  Protection
NEMA IP Against Against
Rating Equivalent NEMA De nition Solids Liquids

3 IP54 Enclosures 5= 4=
constructed for Protected Protected
either indoor or against against
outdoor used to dust - water
provide a degree Limited to sprayed
of protection to ingress (no from all
personnel against harmful directions -
incidental contact deposit) Limited to
with the enclosed ingress
equipment; to permitted.
proved a degree
of protection
against falling
dirt, rain, sleet,
snow, and
windblown dust;
and that will
undamaged by
external
formation of ice
on the enclosure

3R IP14 Enclosures 1= 4=
constructed for Protected Protected
either indoor or against against
outdoor used to solid water
provide a degree foreign sprayed
of protection to objects of from all
personnel against 50mm in directions -
incidental contact diameter Limited to
with the enclosed and ingress
equipment; to greater permitted.
provide a degree
of protection
against falling
dirt, rain, sleet,
and snow; and
that will be
undamaged by
external
formation of ice
on the enclosure

https://www.siemon.com/en/home/support/compliance/nema-ratings-and-ip-equivalents 2/8
4/21/2020 NEMA Ratings and IP Equivalency Chart

Protection  Protection
NEMA IP Against Against
Rating Equivalent NEMA De nition Solids Liquids

3S IP54 Enclosures 5= 4=
constructed for Protected Protected
either indoor or against against
outdoor use to dust - water
provide a degree Limited to sprayed
of protection to ingress (no from all
personnel against harmful directions -
incidental contact deposit) Limited to
with the enclosed ingress
equipment; to permitted.
provide a degree
of protection
against falling
dirt, rain, sleet,
snow, and
windblown dust;
and in which the
external
mechanism(s)
remain operable
when ice laden.

4 IP66 Enclosures 6 = Totally 6=


constructed for protected Protected
either indoor or against against
outdoor use to dust strong jets
provide a degree of water
of protection to from all
personnel against directions -
incidental contact Limited to
with the enclosed ingress
equipment; to permitted.
provide a degree
of protection
against falling
dirt, rain, sleet,
snow, windblown
dust, splashing
water, and hose-
directed water;
and that will be
undamaged by the
external
formation of ice
on the enclosure

https://www.siemon.com/en/home/support/compliance/nema-ratings-and-ip-equivalents 3/8
4/21/2020 NEMA Ratings and IP Equivalency Chart

Protection  Protection
NEMA IP Against Against
Rating Equivalent NEMA De nition Solids Liquids

4X IP66 Enclosures 6 = Totally 6=


constructed for protected Protected
either indoor or against against
outdoor use to dust strong jets
provide a degree of water
of protection to from all
personnel against directions -
incidental contact Limited
with the enclosed ingress
equipment; to permitted.
provide a degree
of protection
against falling
dirt, rain, sleet,
snow, windblown
dust, splashing
water, hose-
directed water,
and corrosion;
and that will be
undamaged by
thee external
formation of ice
on the enclosure

5 IP52 Enclosures 5= 2=
constructed for Protected Protected
indoor use to against against
provide a degree dust - direct
of protection to Limited sprays of
personnel against ingress (no water up to
incidental contact harmful 15° from
with the enclosed deposit) the
equipment; to vertical.
provide a degree
of protection
against falling
dirt; against
settling airborne
dust, lint, bers,
and yings; and to
provide a degree
of protection
against dripping
and light
splashing of
liquids.

https://www.siemon.com/en/home/support/compliance/nema-ratings-and-ip-equivalents 4/8
4/21/2020 NEMA Ratings and IP Equivalency Chart

Protection  Protection
NEMA IP Against Against
Rating Equivalent NEMA De nition Solids Liquids

6 IP67 Enclosures 6 = Totally 7=


constructed for protected Protected
either indoor or against against the
outdoor use to dust effects of
provide a degree temporary
of protection to immersion
personnel against between
incidental contact 15cm and
with the enclosed 1m.
equipment; to Duration
provide a degree of test 30
of protection minutes.
against falling
dirt; against hose-
directed water
and the entry of
water during
occasional
temporary
submersion at a
limited depth; and
that will be
undamaged by the
external
formation of ice
on the enclosure.

https://www.siemon.com/en/home/support/compliance/nema-ratings-and-ip-equivalents 5/8
4/21/2020 NEMA Ratings and IP Equivalency Chart

Protection  Protection
NEMA IP Against Against
Rating Equivalent NEMA De nition Solids Liquids

6P IP67 Enclosures 6 = Totally 7=


constructed for protected Protected
either indoor or against against the
outdoor use to dust effects of
provide a degree temporary
of protection to immersion
the personnel between
against incidental 15cm and
contact with the 1m.
enclosed Duration
equipment; to of test 30
provide a degree minutes.
of protection
against falling
dirt; against hose-
directed water
and the entry of
water during
prolonged
submersion at a
limited depth; and
that will be
undamaged by the
external
formation of ice
on the enclosure

https://www.siemon.com/en/home/support/compliance/nema-ratings-and-ip-equivalents 6/8
4/21/2020 NEMA Ratings and IP Equivalency Chart

Protection  Protection
NEMA IP Against Against
Rating Equivalent NEMA De nition Solids Liquids

12 and IP52 Enclosures 5= 2=


12K constructed Protected Protected
(without against against
knockouts) for dust - direct
indoor use to Limited to sprays of
provide a degree ingress (no water up to
of protection to harmful 15° from
personnel against deposit) the
incidental contact vertical.
with the enclosed
equipment; to
provide a degree
of protection
against falling
dirt; against
circulating dust,
lint, bers, and
ying; and against
dripping and light
splashing of
liquids

13 IP54 Enclosures 5= 4=
constructed for Protected Protected
indoor use to against against
provide a degree dust - water
of protection to Limited to sprayed
personnel against ingress (no from all
incidental contact harmful directions -
with the enclosed deposit) Limited to
equipment; to ingress
provide a degree permitted.
of protection
against falling
dirt; against
circulating dust,
lint, bers, and
yings; and
against the
spraying,
splashing, and
seepage of water,
oil, and
noncorrosive
coolants.

 
https://www.siemon.com/en/home/support/compliance/nema-ratings-and-ip-equivalents 7/8
4/21/2020 NEMA Ratings and IP Equivalency Chart

Connecting The World To A Higher


Standard

Global Headquarters:
The Siemon Company
Siemon Business Park
101 Siemon Company Drive
Watertown, CT 06795-0400 USA
See worldwide of ces

Phone: (1) 860.945.4200


Fax: (1) 860.945.4225
Email: Ask Siemon or
customer_service@siemon.com

Copyright © 1995-2020 Siemon | Privacy Policy | Partner Support


Center | Careers

https://www.siemon.com/en/home/support/compliance/nema-ratings-and-ip-equivalents 8/8

You might also like